Page 1: Brilliant automation solutions

BRILLIANT AUTOMATION SOLUTIONS

Solutions for Recession

Page 2: Brilliant automation solutions

Index

1

2

3

4

Sr. No. Particulars Slide No.

Who we are? 3

Our product 5

6HT-GC500?

8HT-MC100

Page 3: Brilliant automation solutions

Who we are ???

Page 4: Brilliant automation solutions

 Brilliant Automation Solutions specializes in Grid synchronization, manufacturing,

installation, testing and commissioning of complete range of  Load

Sharing/Synchronizing Panels

Who we are ?

Page 5: Brilliant automation solutions

Our product ???

HT-MC100 HT-GC500

Page 6: Brilliant automation solutions

HT-GC500Multiple paralleling gen-sets control with internal load - sharing and synchronizer Computed Measures

Active power meter, Reactive power meter, Apparent power meter, Power factor: Total and phase by phase, Active and reactive energy counter, Hour counter, hour counter for main./rental. Start Counter.

Generator Protections Under frequency (81U), Over frequency (81O), Under voltage (27), Overvoltage (59), Power direction (32), Loss of excitation (Reverse reactive 32RQ), Time dependent overcurrent (51), Instantaneous overcurrent (50), Phase sequence, Current and Voltage unbalance, Ground Fault Protection (51N) (alternative to Neutral current measurement). Phase overcurrent with voltage restraint/control (51V)

Loss of Mains Protections Fast Underfrquency (81U), Over frequency (81O), Under voltage (27) and Overvoltage (59) protection. Rate of change of frequency (df/dt, RoCoF, 81R). Vector surge/jump Inputs, and aux. functions 18 Programmable digital inputs 3 Analogue inputs, if not used, can be used as not insulated digital inputs 2 Analogical input (0...10V)

Page 7: Brilliant automation solutions

HT-GC500Multiple paralleling Gen-sets control with internal load - sharing and synchronizer Embedded functions

• Internal active and reactive Load-sharing • Power regulation • Reactive power sharing • Power factor regulation • Synchronization (via CAN or Via PWM) • Load Management • CAN interface for ECU interface (J1939 and MTU MDEC) and • Insulated CAN interface for PMCBUS application (LOAD– SHARING and parallel

management) • Up to 16 generator sets connected together • Multilanguage display: English, Italian, French and Russian Supported Plants • SPM, SSB, SPtM, SSB+SSTP, SPtM+SSB, MPM, MSB, MPtM, MSB+MSTP,

MPtM+MSB.

Other Technical data • Supply voltage: 7…32 Vdc • Power consumption: typical less than 2W (AUTO mode, STAND-BY, AMF active, LCD

Lamp Saving active). • Nominal Gen-Set frequency: 50 or 60 Hz • LCD: transflective with LED backlight. • Operating temperature: -25 °C to 70 °C Protection degree: IP55

Page 8: Brilliant automation solutions

HT-MC100 PARALLEL SYSTEM SUPERVISOR

MC100 controller is aimed for managing multiple parallel systems. In particular MC100 is able tocontrol the global circuit breaker and generator functions operating as Master unit.In particular MC100 controller is an automatic control unit born to safety manage the followingtype of power plants with and without MCB and MGCB management:• MPM (Multiple Prime Mover)• MSB (Multiple Stand-by)• MSB + MSTP (Multiple Stand-by + Multiple Short Time Parallel)• MPtM (Multiple Parallel to Mains)• MSB + MPtM (Multiple Stand-by + Multiple Parallel to Mains)• True RMS readings on bus and mains voltages and currents• Additional current measurement for neutral or differential protection• Active, Reactive and apparent power measurement for Mains and, Load Generators• MCB and MGCB synchronization of multiple generators• Graphic display• 18+3 programmable digital input• 18 programmable digital output• RS232 interface port with MODBUS RTU protocol• Additional RS232 or RS485 interface port Real Time Clock• Events and data logging (100)• Engine speed measurement by pick-up or W• Optional external Ethernet interface• Load shedding (it’s possible to set many thresholds in base of the nominal power available on

the bus. In case of that threshold is exceeded in island mode operation, not privileged loads are enabled).

Page 9: Brilliant automation solutions

Computed MeasuresActive power meter, Reactive power meter, Apparent power meter, power factor: Total and phase by phase.Active and reactive energy counter. Total active and reactive power of all generator sets with GCBclosed.Total active and reactive Energy counter of all generator sets with GCB closed.Max. nominal power available on the bus bar. Load percentage of generators running with GCB closed

HT-MC100 PARALLEL SYSTEM SUPERVISOR

Loss of Mains protectionsUndervoltage (27)Overvoltage (59)Underfrequency (81U)Overfrequency (81O)ROCOF (df/dt, 81R),Vector jump

PEAK-SHAVING mode. This mode allows to automatically starts to run the generator sets and to operate in Import/Export only if the threshold of imported power is exceeded.Import/Export for MPtM (Multiple Parallel to Mains) plantsBase load management for MPtM (Multiple Parallel to Mains)plants.Power factor management/regulation for MPtM (Multiple Parallel to Mains) plantsSoft Load transfer from Mains to Gen sets and vice versaLoss of mains protections for gen sets running in parallel with the Mains