_,...___,Ji ........ ..._,_, .. ,.,_, �.. lo•' -- '�-- ... 1 - •--�C Electrical System' Design . >
•.'
• Hydroelectric T-G Control Systems• Generator Control & Protection
Systems• Generator Excitation System
Application• Emergency Backup Systems
• System Power Factor Correction• Power Distribution Systems
• Automation Control
• System Protection
• Drive Systems Application
• SCADA Control Systems
• Diesel GenSet Control Upgrade• Synch Motor Control Systems
• Synch Condenser Control Systems
_d1.,: j urnkey Installation Upgrade Packages jSt, • I ' ,
• Generator Excitation Systems• Generator Voltage Regulator Systems• Power System Stabilizers
• Generator Auto/Man Synchronizing Systems
• Generator Protection Systems
• Interface to Plant Control• System Monitoring & Trending• Synch Motor Control Systems
• Synch Condenser Control Systems
• Medium Voltage Switchgear Systems
• Hydroelectric T-G Control Systems
• Drive Systems• Automation Control Systems
E2 Power Systems, LLC Electrical Engineering Services
8115 Shaffer Parkway, Littleton CO 80127
TEL 303. 988.665 9 FAX 303. 988.5714
WEBSITE www.e2powersystems.com
. .• - . .
Generating Syste_m On-Site Services
;iYtconsuliing Services .. . " · · .=,. .. _ .. n.,. ":. ,� .,._, • • � • • •
• Load Flow Reviews• Short Circuit Analysis• Protection Setting & Coordination
• Arc Flash Hazard Review
• System Evaluation & Enhancement Study
• Spec / Procedure Development
• Expert Witness• System Feasibility• Mining Electrical System Reviews
• PE Reviews & Inspections
• Protective Relay & Meter Calibration ·
• Demand Power Analysis
• Insulation Power Factor Testing
• Unit & Auxiliary Transformers
• HV Switchgear & MCCs
• I PP / Utility Acceptance Testing
• Drive Systems (VFD & L(I)
• Ground System
•
•
•
•••
•
•
•
•
•
System Troubleshooting &MaintenanceProtective Relay Calibration Power System Stabilizer CommissioningExcitation System Tuneups Voltage Regulator System Tuneups NERC Compliance TestingStartup & Testing Services Technical Direction Services Construction Management Technical Training SeminarsThird Party Technical Representative
- C)
- 0-,.
- co
- ,-....
- ""°
- �
- -.::I"
- C"")
- C'4
-�
=- -5 - -=
Allowable Ampacities of Insulated Conductors Rated 0-2000 Volts, Not More Than Three Conductors in Raceway or Cable or Earth (Directly Buried), Based on Ambient Temperature of 30°C (86°F) - Reference Onl�. See NEC Table 310-16 for Details.
SIZE TEMPERATURE RATING OF CONDUCTOR 75°C (167°F) 90°C (167°F)
TYPES TYPES FEPW TBS, SA
RH, RHW SIS, FEB AWG THHW, THW FEPB, Ml kcmil THWN, XHHW RHH, RHW-2
USE, ZW THHN, THHW THW-2, THWN-2
USE-2, XHH, XHHW XHHW-2, ZW-2
COPPER
18 - 1416 - 1814 20 25 12 25 30 10 35 40 8 50 55 6 65 75 4 85 95 3 100 110 2 115 130 1 130 150
1/0 150 170 2/0 175 195 3/0 200 225 4/0 230 260 250 255 290 300 285 320 350 310 350 400 335 380 500 380 430 600 420 475 700 460 520 750 475 535 800 490 555 900 520 585 1000 545 615 1250 590 665 1500 625 705 1750 650 735 2000 665 750
Ohms Law: E =IX R
E = Voltage I= Amperes R = Resistance
Conversion Factors: CO= 5/9 (F0 -32)
1 Centimeter= .3937 Inches
1 Meter= 3.281 Feet 1 Meter= 1.0936 Yards
1 Kilometer= .6214 Miles
F0 = 9 /5C0 +32
1 Inch= 2.54 Centimeters
1 Foot= .3048 Meters
1 Yard= .9144 Meters
1 Mile= 1.6093 Kilometers
1 Horsepower= .7 457 Kilowatts 1 Kilowatt= 1.341 Horsepower
1 Kilogram= 2.20 Pounds 1 Year= 8,766 Hours
Hydropower Potentia l:
P = QHE / 11.6 H = Gross Head in Ft. E = System Efficiency
Q = Flow in Cubic Ft/Sec. P = Capacity in KW
Trans former Formulas:
HA = Full Load Amps
FLA (10) = KVAx 1000 Circuit Volts
lscA = Short Circuit Amps
FLA (30) = KVA x 1000 ( 1.732) (Volts)
lsCA = FLA x 1 000 Unit Impedance
Power Factor - Power Triangle
ACTIVE POWER (KW)
POWER FACTOR = PF = COS 0 = ACTIVE POWER = KW APPARENT POWER KVA
SIN 0 = REACTIVE POWER = KVAR APPARENT POWER KVA
KW= (KVA) (PF) = (KVA) (COS 0) KVAR = (KVA) (SIN 0)
(KVA)2 = (KW)2 + (KVAR)2 KV A = .J�(KV
..,.,..
A -::-:,CO-:,-::
S0C""'.'"
) 2-+ """"(I K:,-:--:-
v A-=
sI""""
N0,.,...,..
) 2 LAGGING PF:
Active & Reactive Power Flow in Same Direction LEADING PF:
Active & Reactive Power Flow in Opposite Directions
Useful Electrical Formulas for Determining Amperes, Horsepower, Kilowatts, and KVA
To Find Direct Alternating Current
Current Single Phase Three Phase E = Volts
Amperes when HP x 746 HP x 746 HP x 7 46 I= Amperes Horsepower is known ExEff EX Eff X PF 1.73 x E x Eff x PF
KVA = Kilovoltamperes Amperes when KW x 1000 KW x 1000 KW x 1000 Kilowatts are known E EX PF 1.73 x Ex PF HP= Horsepower Amperes when KVA KVA x 1000 KVA x 1000 PF = Power Factor is known E 1.73 x E
Kilowatts hl IX EX PF Ix Ex 1.73 x PF Eff = Percent Efficency 1000 1000 1000 KW= Kilowatts
KVA hl Ix Ex 1.73 1000 1000 Eff = Output
Horsepower - (output) lxExEff I X EX Eff X PF I x E x 1.73 x Eff x PF Input 746 746 746