DESCRIPTION
EUSO-BALLOON DESIGN REVIEW, 18.12.2012, CNES TOULOUSE. Electrical Architecture. Pierre PRAT APC, Paris. - G rounding - Harness Shielding - PDM Electrical Architecture - DP Electrical Architecture. Grounding. Grounding. Grounding principle In order to avoid ground loops: - PowerPoint PPT Presentation
Citation preview
- Grounding
- Harness Shielding
- PDM Electrical Architecture
- DP Electrical Architecture
E U S O - B A L L O O N D E S I G N R E V I E W, 1 8 . 1 2 . 2 0 1 2 , C N E S T O U L O U S E
Pierre PRATAPC, Paris
Electrical Architecture
Grounding
CDR – 18.12.2012
Electrical Architecture 2
Grounding
Grounding principleIn order to avoid ground loops:
• Use of galvanically isolated DC/DC converters• Primary grounds (28V Battery) are connected on Mechanical ground of PWP • Secondary grounds of DC/DC converters are connected on a single point on Mechanical ground of sub-equipments (DP, PDM)• Mechanical grounds are connected together• Differential links (LVDS) between HK, CCB and PDM_Board, HVPS-1
CDR – 18.12.2012
Electrical Architecture 3
Harness Shielding
According to the recommendations of Johan Panh (EMC expert at CNES):•Primary power supplies : twisted pairs, not shielded• Secondary power supplies :
• LVPS-PDM <==> PDM_Board : twisted pairs, shielded, with shielding connected to mechanical ground (360°) on each sides (HF immunity)•HVPS-1 <==> HVPS-2 : shielded, with shielding connected to mechanical ground on both sides•LVPS-HK, LVPS1-DP, LVPS2-DP <==> HK, CCB, CLKB, GPSR, CPU, DST: twisted pairs, not shielded
•Differential digital links: twisted pairs, shielded, with the shielding connected to mechanical ground (360°) on each side
CDR – 18.12.2012
Electrical Architecture 4
Harness Shielding
CDR – 18.12.2012
Electrical Architecture 5
PDM Electrical Architecture
CDR – 18.12.2012
Electrical Architecture 6
Overview
PDM Electrical Architecture
CDR – 18.12.2012
Electrical Architecture 7
PDM Board
PDM Electrical Architecture
CDR – 18.12.2012
Electrical Architecture 8
HVPS
PDM Electrical Architecture
2 HVPS boxes in PDM box:HVPS-1:
2 CV DC/DC (28V & 3.3V) for ground isolation SPI I/F with HK LVDS I/F with PDM-Board (switch pulses) 3 DACs (HV tuning) 3 Cockcroft-Walton Converters
HVPS-2: 6 DACs (HV tuning) 6 Cockcroft-Walton Converters
CDR – 18.12.2012
Electrical Architecture 9
HVPS
DP Electrical Architecture
CDR – 18.12.2012
Electrical Architecture 10
Overview
DP Electrical Architecture
CDR – 18.12.2012
Electrical Architecture 11