Upload
votruc
View
216
Download
0
Embed Size (px)
Citation preview
Samsung Electronics Co., LTD.Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742www.dvmsystem.com Version.1
When a single air conditioner creates the perfect coolness Imagination Lives
Experience this year’s Ceiling air
conditioners, with the style and
the functionality.
Space for Partnership
CAC2009
SAMSUNGSystem Air Conditioner
Perfect fit for every spaceA perfect air conditioner is different, it depends on the application and end user. Each building and
space has different objectives and different people inside. Perfect fit, Samsung Commercial Air
Conditioners were designed as if it was customized to fit in to your interior design. Slim and
compact, with aerodynamically designed parts will deliver the cool air with style.
SAMSUNG ELECTRONICS HOME APPLIANCE PRODUCT AWARDSTechnology can contribute to the development of a greener, cleaner world andincrease quality of life. This is a philosophy we have held at Samsung for over 30years. Ever since its establishment in 1973, Samsung Electronics has concentrated on developing environmentally friendly products and has convergedincreasingly sophisticated digital technology with its appliance products to attain astrong technological advantage in improving consumers' quality of living with the ultimate in convenience and style.
Big Confidence Global Leading
Company >> SAMSUNGSince day one, Samsung Electronics has committed itself to becoming a leader in every facet of its market initiatives. The result is the growth of a brand that’s synonymous with impeccable standards, high quality products,and an unwavering dedication to the customer. Through continuous creativity and the development of highlyinnovative products, Samsung has captured the hearts and minds of customers worldwide, which will propel ourcompany and our brand well into the future.
SAMSUNG’S BRAND VALUEIn the Digital era, products are being distinguished by their
brand in addition to their functions or quality. In 1999 Samsung
Electronics has implemented its global brand communication
strategy. Since then, based on the research conducted by
Interbrand INC., USA, Samsung Electronics has become one of
the fastest growing brands equities from 6.4 billion USD (2001)
to over 17.7 billion USD (2008) and is now ranked 21st on
Interbrand's Top100 Global Brand List.
Samsung has increased its value by emphasizing technology as
a life innovator. Samsung will remain close to the customer
through its technologies contributing to a higher quality of life.
GLOBAL BUSINESS NETWORKSamsung's thrust on Product Innovation and R&D has given the company a competitive edge in the marketplace. With an
investment of over USD 4.59 billion, Samsung operates 16 R&D centers worldwide and employs 27,000 researchers of which
2,500 hold a Ph. D. As a result, Samsung has already applied for 1600 patents in the USA. The focus of the R&D center is to
customize electronics products to meet the Specific needs of consumers in that region. Samsung R&D Centers are helping the
company to continuously innovate and introduce products customized for today’s global market.
6 Global Operation Centers
10 Global Headquarters
EuropeStuttgart
CIS
Milano
ME Asia Africa
India
SW Asia
SE Asia
Delhi
ChinaKorea
ShanghaiJapan Los Angeles
Mexico
US Chicago
Latin America
Malaysia
Thailand
London
7 Design Centers
5 HA R&D Centers
2009 SAMSUNG Ceiling Air Conditioner
02 | INTRODUCTION 09 | Line-up 12 | S-Inverter Technology
14 | Indoor Units 52 | Control Systems
Four Seasons of HopeSamsung's Four Seasons of Hope is about kids. It's about using the power of our brand to give something back to the
communities we serve.
Samsung's Four Seasons of Hope supports community-based foundations and charities headed by some of this country's
favorite sports legends. Samsung pledges to raise national awareness and funds for these outstanding charities and to
identify how others can also make a difference in the lives of these children and families.
Samsung Recycling DirectSM
All good things come to an end. Let's make sure it's a Green end.As technology continually evolves, so will your digital lifestyle. When you upgrade your consumer electronics, you will need
to recycle your old products responsibly. That's why we're proud to reaffirm our commitment and responsibility to recycle
DirectSM using the new Samsung Recycling program launched on October 1st, 2008.
Thinking of You.
Making industry-leading products is only part of the big picture. Our commitment to creating a better world for futuregenerations is equally as important. We strongly believe that if future generations aren't given the opportunity to succeed, we definitely won't. As a corporate citizen, we have dedicated ourselves to nurturing ourlocal communities through corporate social responsibility and co-prosperity initiatives. Samsung has also remainedsteadfast when it comes to supporting education initiatives, helping to preserve the "greening" of the planet whereyou live.
"A global leader is not only responsible for that which lies within its walls but alsofor that which lies beyond them."
Reported by GreenpeaceSamsung comes in second place with 5.7, scoring well on
chemicals and waste criteria. Samsung's score on e-waste is
helped by getting top marks for reporting recycling rates of
137% for TVs (based on past sales 10 years ago, the average
life span, since when Samsung's TV sales have increased
10-fold), 12% for PCs (based on 7 year lifespan) and 9%
for mobile phones (based on 2 year lifespan). It also scores well
on its use of recycled plastic, which is 16.1%, though only 0.2%
is post-consumer plastic, with a goal to increase to 25% by 2008.
Nokia:Clear leader after improving take-back inIndia.
SAMSUNG / Good scores on chemicalsand e-waste criteria.
Fujitsu Siemens:New deadline for removal ofBFRs and PVC but still poor on recycling.
Sony Ericsson:Good on toxic chemicals andenergy but very poor on recycling.
Sony:Good on toxic chemicals, room forimprovement on energy.
LG:Improved score on recycling and energy.
Toshiba:Improved climate policy, but poor on recycling.
Dell:Dropping down with poor scores on climate policy.
HP:Slightly improved score but no productsfree of most toxic chemicals.
Acer:Good on chemicals policy but poor onenergy policy.
Panasonic:Needs to improve recycling andamount of renewable energy.
Philips:Worst company on recycling with additional penalty for negative lobbying in Europe.
Apple:Progress on eliminating toxics from newproducts but needs to improve on recycling andenergy.
Lenovo:New US tack back scheme, but still noproducts free of worst toxic chemicals.
Motorola:Only phone company not to set atimeline for eliminating worst toxic chemicals.
Sharp:Most points on toxic chemicals, poor onrecycling and energy.
Microsoft:Very poor on recycling and energy.
Nintendo:Zero on most criteria except chemicalsmanagement and energy.
[Standard for the second quarter, 2008]
7
5.7
5.5
5.3
5.3
4.9
4.7
4.7
4.7
4.5
4.5
4.3
4.1
4.1
3.7
3.1
2.2
0.8
Eco-labels & DeclarationSamsung Electronics makes an effort to develop environment-
friendly products that minimize the negative impacts on the
environment in every aspect of its products, from raw material
procurement, production, transportation, usage, and final
disposal. Concerns for the environment are at the core of each
product development.
Samsung's environment-friendly technologies and recycling
programs have received global approval, receiving well-known
awards and recognitions worldwide.
Samsung eco mark Energy mark Korea Eco Mark Korea
Ecoflower EU Energy Star Mark TCO Sweden
Blue Angel Germany EPEAT US Eco Mark Korea 2
Type 9K Btu/h
2.6 kW
12K Btu/h
3.5 kW
18K Btu/h
5.2 kW
21K Btu/h
6.0 kW
24K Btu/h
7.0 kW
30K Btu/h
9.0 kW
36K Btu/h
10.5 kW
48K Btu/h
14.0 kW
Non-inverter
S-Inverter
R-Inverter
1Phase
1Phase
3Phase
1Phase
3Phase
Technology
CapacityR410A
2009 Product Line-up This year’s product line-up still supports a wide range ofchoices, all of them equipped with Samsung’s advancedtechnology.
OUTDOOR UNITS
08092009 Samsung Ceiling Air Conditioners'Eco-friendly'- Samsung
Preserves the nature you live in.Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener, healthierlife for you and the generations that follow, Samsung's environmentally friendly technologies work to make theworld a more beautiful place.
Air & Water ConservationAs a leading innovator of environment-friendly products and technologies, Samsung products already drastically reduce the strains on nature's valuable resources. Samsung uses R-600, a natural refrigerant, and cyclopentane insulation in its refrigerators, which do not promote global warming and does not add to the greenhouse effect. Samsung's water-efficient washing machines also use less detergent and water withoutaffecting cleanliness, helping to conserve water.
Use Less, Save MoreSamsung products are energy efficient, receiving Energy Grade A+ in the EU and ENERGY STAR in the U.S.Samsung washers with its ceramic heaters use less power, which saves you energy, money, and time. Thisenergy-efficient technology protects you and nature, giving you a greener lifestyle.
Global RecyclingSamsung Electronics is making significant efforts to save the environment and complies with the WEEE(Waste Electrical and Electronic Equipment) directive by joining or establishing the recycling schemes for eachcountry.
Samsung Eco-Friendly System Air ConditionerMaking continuous efforts to stay eco-friendly, Samsung's air
condition-ers use R-410A, an environmentally friendly refrigerant to
help rid the air of pollutants and restrain the use of materials with high
global warming potential (GWP). Most Samsung products have
received Energy Grade A+ in the EU and ENERGY STAR in the U.S.
These energy-efficient air conditioners not only save you money, but
help conserve the environment.
2009 Product Line-up
INDOOR UNITS
This year’s product line-up still supports a wide rangeof choices, all of them equipped with Samsung’sadvanced technology.
R410A
9K Btu/h
2.6 kW
12K Btu/h
3.5 kW
18K Btu/h
5.2 kW
24K Btu/h
7.0 kW
30K Btu/h
9.0 kW
36K Btu/h
10.5 kW
48K Btu/h
14.0 kW
21K Btu/h
6.0 kWTechnologyType Capacity
10112009 Samsung Ceiling Air Conditioners
1Way cassette
4Way cassette
Ceiling
Slim Duct
MSP Duct
Mini 4Way cassette
Console
2Way cassette
Inverter
Inverter
R-Inverter
Inverter
Inverter
Inverter
Inverter
Inverter
R - Inverter
Non-inverter
Non-inverter
Non-inverter
Non-inverter
Non-inverter
12132009 Samsung Ceiling Air Conditioners
25 C
24 C
23 C
25 26 27 28 29 30 31 10 12 14 16 18 20 22 24 26
27'21"
31'24"
17'41"
27'23"
Faster Faster
Fast Cooling and HeatingWhen you change the temperature setting, the airconditioner will use the compressor's maximumcapacity to quickly reach the desired temperature,resulting in 15% faster cooling and 50% faster heating.
Comfortable TemperatureThe S-Inverter Air Conditioner works at maximumcapacity at start up. As soon as the temperaturereaches the desired set temperature, it finely adjuststo cope with any changes. This means less temperaturefluctuation and assures you greater comfort that canbe achieved in minutes.
High EfficiencyThe S-Inverter technology gives you powerful, speedycooling and heating at minimum electricity consumption,so you can reduce energy waste and save money.
Up to 50% Energy SavingAfter reaching the set temperature, the S-Inverter AirConditioner changes its operation mode to economic.By avoiding inefficient and frequent switching on andoff of the compressor, the S-Inverter saves up to 50%in energy consumption compared with a non-inverterair conditioner.
200 300 400 500 600
302Wh/h
621.4Wh/h
Saving
Silent OperationEnjoy peace and quiet. The air conditioner's compressor operates at the lowest speed possible tomaintain the desired temperature, so there's lessmotor and fan noise.
20dB 25 30
27dB Silent
Wide Temperature PerformanceNo need to worry about using an external unit insevere temperatures with a Samsung air conditioner.With a wider temperature allowance, the unit can coolin the burning heat of 50°C or heat in the freezingcoldness of -20°C to provide comfort in your home. -10 0 10
Wider operation Range
20 30 40 -20 -10 0 10 20 30
-10oC ~ 15oC
-20oC ~ 24oC
Wider operation Range
Comfortable
S-InverterSteady Temperature Fluctuation
Non InverterHigh Temperature Fluctuation
Uncomfortable(Energy Loss)
Uncomfortable(Energy Loss)In reducing electricity costs for an air conditioner, an inverter is a must. Samsung’s S-Inverter
technology lowers energy consumption by up to 50% compared to a conventional air conditioner.
Its powerful and delicate control lets you reach the desired temperature quickly and maintains
precise temperatures so there’s less fluctuation and less motor run-time, which means quieter
operating noise and less energy waste.
Strong and Quiet S-Inverter
INDOOR UNITS01
14152009 Samsung Ceiling Air Conditioners
Cold air, delivered evenly toevery corner of your spaceIndoor units made just for you! Samsung’s indoor units have their own individual
unique features for the perfect air throughout the entire space. Indoor units
designed to fit all the different types of space. It will make you feel like owning
your own customized air conditioner just for you.
18
22
28
30
| Slim 1Way Cassette
| 4Way Cassette
| Mini 4Way Cassette
| 2Way Cassette
| Cassette Type
34
36
| Slim Duct
| MSP Duct
| Duct Type
44
48
| Console
| Ceiling
| Floor & Convertible Type
Wide BladeThe new cassette type air conditioner is equipped with uniquely designed blades that are wider to provide evencooling and heating power throughout the room.
WIDEWIDEWIDEWIDE
64mm
46mm
WIDER
Airflow is directed towards theceiling which cause ceilingsoiling.
Airflow is directed downwardswithout having contact with theceiling.
Ceiling Soiling PreventionNewly designed panel will control the air direction to avoidhaving contact with the ceiling. This new design will preventthe ceiling soiling and keep your interior cleaner than evereven, after long period of operation.
Conventional Blade
Ceiling Ceiling
New Blade
600(mm) 650
Lift-up Range
700 750
750mm
700mm
High Lift-up Drain PumpThe lift-up drain pump lifts condensed water up to 750mm,compared to the competitor’s 700mm, allowing for flexibleand convenient installation.
Fresh Air IntakeWith optional installation of an air intake motor, fresh aircan enter through the cassette unit so you have fresherair in the room.
Sub DuctThe Sub Duct lets you use the same air conditioner unit tocool another smaller space nearby. (The cassette unit is fitted with a knock-out component to accommodate this.)
Quick Connection of Drain PipeSamsung's unique drain pipe prevents leaks and is easierto install with no need to use tape or adhesives.
FRESHFRESHFRESHFRESH
SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
HIGHHIGHHIGHHIGH
Company A
Fresh air
Motor
Samsung
Cassette type Air conditionersSamsung’s Ceiling type air conditioner offers four different types of models with stylish designtogether with functionality. Indoor units that blends in and adds elegancy to any type of spaceis the origin of the cool air that fills the entire space.
16172009 Samsung Ceiling Air Conditioners
Slim 1Way CassetteSuper slim design helps easier installation and the quiet operation still provides the strongest air.
Slim and Compact Design
Slim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.
10.5kg
17kg
38% Down
4kW R410A model Weight
Only 135mm thickSamsung introduces the world's slimmest indoorair conditioner unit. Only 135mm thick, the slim 1Way Cassette air conditioner can be installedpractically anywhere.
Lighter indoor unitThe first to apply ABS cabinets into its indoorunits, Samsung has achieved the lightest unitson the market. Its slim lightweight design makesinstallation and maintenance a breeze.
Ensure that there is sufficient installation space. Allow at least170mm for the installation.
NOTE
Min. 170mm
Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.
25dB
35dB
30dB
43dB
Low
High
Fan speed Noise level
Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit,causing leakage and odors. Samsung's air conditioners are equipped with a check valve built directlyinto the drain pump to prevent water from flowing backward.
Check ValveOptional Accessories
PSSMAMR-CH01MWR-TH01 MWR-SH00
Individual Controllers
Panel
WIDE BLADEQUICK CONNECTION OF DRAIN PIPE
CEILING SOILINGPREVENTION
HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
18192009 Samsung Ceiling Air Conditioners
MWR-WS00MWR-WE00
135m
m
155m
m
Drain pan is included within panel
Slim 1Way Cassette
Specification | Slim 1Way Cassette
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
SH026EAV1UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
980/2,600/3,500950/3,300/4,600245/695/1,120210/910/1,300
3.74(A)3.63(A)
1.6/3.3/5.21.4/5.3/6.46.35(1/4)9.52(3/8)
1/220-240/50
SH026EAV1PSSMA
CROSS FLOW FAN8
970X135X4101,164X212X478
10.0/13.61,180X25X4601,250X126X530
3.1/4.530/25
DEFAULT
UH026EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950201550
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
SH035EAV1UH035EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
980/3,500/4,100950/4,000/4,750250/1,140/1,420210/1,160/1,390
3.07(A)3.45(A)
1.6/5.3/6.61.4/5.5/6.86.35(1/4)9.52(3/8)
1/220-240/50
SH035EAV1PSSMA
CROSS FLOW FAN8.5
970X135X4101,164X212X478
10.0/13.61,180X25X4601,250X126X530
3.1/4.532/27
DEFAULT
UH035EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950201550
20212009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
4Way CassetteWith the air coming out from four different places, the 4Way Cassette type indoor units provide conditioned air to everycorner of the space.
Optional Accessories
Panel
New Turbo Fan
Quiet OperationImagine a room of cool calmness. Theaerodynamically designed ‘Turbo Fan'minimizes noise from the turbulenceof blade movement. Therefore noiseis less than conventional models.
Uniform DistributionThe new 'Turbo Fan' with wide bladesprovides extreme cooling and heatingpower from 4 separate outlets so theentire room gets cool or warm faster.Now, every nook and cranny is comfortable.
Easy LevelingEach corner portion of the panel is detachable,which gives easier access to adjust the height,therefore leveling and installation is much easierand quicker than before.
Compact SizeThe 4Way cassette type unit has gotten even slimmer.Now only 218mm thick (5.2/7.0/9.0kW), 24% slimmercompare to competitor’s 288mm (9.0kW). It's stillthe industry leader in compactness and is eveneasier to install in tight spaces.
Efficient Cooling3-dimensional shaped blade, which has the world wide patent, is able to spread cool or warm air further andevenly to all corners of the space.
Conventional 4Way
Conventional 4Way
New 4Way
New 4Way
Detachable corners make installationand height adjustments much easier.
Air distribution
Detaching the whole panel tookmore time.
218mm
Air distribution
Outlet1
Outlet2
Outlet3
Outlet4
‘A’ View
‘B’ View
‘C’ View
WIDE BLADEFRESH AIR INTAKE
SUB DUCTQUICK CONNECTION OF DRAIN PIPE
CEILING SOILINGPREVENTION
HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK
P4SMA
Stylish Panel DesignThe stylish panel is well harmonized with any interior design.
22232009 Samsung Ceiling Air Conditioners
MR-CH01MWR-TH01 MWR-SH00
Individual Controllers
MWR-WS00MWR-WE00
24252009 Samsung Ceiling Air Conditioners
4Way Cassette
Specification | 4Way Cassette
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
CH070EAV1UH070EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
2,100/7,100/8,4002,000/8,000/11,600
510/2,120/2,700500/2,190/3,750
3.35(A)3.65(A)
2.8/9.3/12.12.6/9.6/16.9
6.35(1/4)15.88(5/8)
1/220-240/50
CH070EAV1P4SMA
TURBO FAN17.2
840X218X840926X280X925
31/35950X35X950
1,042X103X1,0427.0/10.336/30
DEFAULT
UH070EAV1TWIN BLDC
R410A880X798X310
1,038X861X41357/61
52-15~43-20~241,900
5030530
CH090EAVUH090EAV
3,200/9,000/10,0003,000/10,000/13,900
750/2,800/3,200580/2,770/4,660
3.21(A)3.61(A)
3.5/12.5/14.12.8/12.2/20.6
9.52(3/8)15.88(5/8)
1/220-240/50
CH090EAVP4SMA
TURBO FAN24
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.339/32
DEFAULT
UH090EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X47295/110
56-15~50-20~242,600
75307.540
CH105EAVUH105EAV
3,200/10,500/12,0002,600/11,200/15,500
700/3,270/3,800580/3,100/5,600
3.21(A)3.61(A)
3.3/14.5/16.83.6/13.7/24.3
9.52(3/8)15.88(5/8)
1/220-240/50
CH105EAVP4SMA
TURBO FAN25.7
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.340/33
DEFAULT
UH105EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X47295/110
56-15~50-20~242,800
75307.540
CH105EAVUH105GAV
3,200/10,500/12,0002,600/11,200/15,500
700/3,270/3,800580/3,100/5,600
3.21(A)3.61(A)
1.3/5.0/6.01.1/5.0/8.69.52(3/8)
15.88(5/8)3/380-415/50
CH105EAVP4SMA
TURBO FAN22.2/25.7
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.340/33
DEFAULT
UH105GAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X47288/93
56-15~50-20~242,800
75307.540
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
CH140EAVUH140EAV
3,800/14,000/15,4003,450/16,000/18,500
900/4,650/5,400750/4,690/5,800
3.01(B)3.41(B)
4/20.6/23.53.6/20.8/26.5
9.52(3/8)19.05(3/4)
1/220-240/50
CH140EAVP4SMA
TURBO FAN30
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.345/38
DEFAULT
UH140EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472105/120
59-15~50-20~243,100
75307.540
CH140EAVUH140GAV
3,800/14,000/15,4003,450/16,000/18,500
900/4,650/5,400750/4,690/5,800
3.01(B)3.41(B)
4/20.6/23.53.6/20.8/26.5
9.52(3/8)19.05(3/4)
3/380-415/50
CH140EAVP4SMA
TURBO FAN28/30
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.345/38
DEFAULT
UH140GAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472105/120
59-15~50-20~242,800
75307.540
CH090EASUH090EAS
3,100/9,000/10,0002,750/9,500/13,000
680/2,800/3,400530/2,630/4,550
3.21(A)3.61(A)
3.2/12.4/15.02.54/11.65/20.0
9.52(3/8)15.88(5/8)
1/220-240/50
CH090EASP4SMA
TURBO FAN24
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.339/32
DEFAULT
UH090EASTWIN BLDC
R410A880x950x320
1043x1062x41178/85
52-15~50-20~242,400
7530555
R-Inverter
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
4Way Cassette
Specification | 4Way Cassette
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling/Heating
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
CH052EAMCUH052EAMCModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
5,4006,0001,9001,950
2.84(C) 3.08(D)
8.58.6
6.35(1/4)12.7(1/2)
1/220-240/50
CH052EAMCP4SMA
TURBO FAN14
840X218X840925X280X925
25/31950X35X950
1,042X103X1,0427.0/10.334/29
DEFAULT
UH052EAMCROTARYR410A
880X648X3101,023X744X413
59/6649
-5~43-5~241,500
30157.525
CH070EAM1CUH070EAM1C
7,0007,2002,4002,350
2.92(C) 3.06(D)
11.0 11.0
6.35(1/4)15.88(5/8)
1/220-240/50
CH070EAM1CP4SMA
TURBO FAN18.5
840X218X840925X280X925
25/31950X35X950
1,042X103X1,0427.0/10.336/30
DEFAULT
UH070EAM1CROTARYR410A
880X648X3101,023X744X413
60/6751
-5~43-5~241,700
30157.540
CH094EAMCUH094EAM1C
9,0009,5003,4003,500
2.65(D) 2.71(E) 15.516.0
6.35(1/4)15.88(5/8)
1/220-240/50
CH094EAMCP4SMA
TURBO FAN21.5
840X218X840925X280X925
25/31950X35X950
1,042X103X1,0427.0/10.339/32
DEFAULT
UH094EAM1CROTARYR410A
880X798X3101,023X891X413
74/8255
-5~43-5~241,800
30157.550
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
CH105EAMCUH105EAMC
10,00010,7003,8303,850
2.61(D) 2.78(E) 17.517.5
9.52(3/8)19.05(3/4)
1/220-240/50
CH105EAMCP4SMA
TURBO FAN24.5
840X298X840925X360X925
28/34950X35X950
1,042X103X1,0427.0/10.340/33
DEFAULT
UH105EAMCSCROLLR410A
880X931X3201,043X411X1,062
87/9256
-5~43-5~242,600
50307.570
CH105EAMCUH105GAMC
10,00010,7003,5603,600
2.81(C) 2.97(D)
6.26.3
9.52(3/8)19.05(3/4)
3/380-415/50
CH105EAMCP4SMA
TURBO FAN24.5
840X298X840925X360X925
28/34950X35X950
1,042X103X1,0427.0/10.340/33
DEFAULT
UH105GAMCSCROLLR410A
880X931X3201,043X411X1,062
87/9256
-5~43-5~242,750
50307.570
CH140EAMCUH140GAMC
14,00015,4005,3005,9002.64 2.61 9.210.0
9.52(3/8)19.05(3/4)
3/380-415/50
CH140EAMCP4SMA
TURBO FAN29
840X298X840925X360X925
29/35950X35X950
1,042X103X1,0427.0/10.345/38
DEFAULT
UH140GAMCSCROLLR410A
932X1,128X3751,091X1,286X472
121/13659
-5~43-5~243,300
50307.570
26272009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
Mini 4Way CassetteFour way airflow for large coverage with more compact size, it is best for the place with smaller ceiling structure.
FRESH AIR INTAKE
QUICK CONNECTION OF DRAIN PIPE
HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK
High Energy EfficiencyNot only is the Mini 4Way cassette air conditioner small and compact, it's energy efficient. Easy operation coupled withhigh efficiency provides you with remarkable performance at extremely low cost.
Fan Speed AdjustmentFan speed can be adjusted by ceiling height. With an easy touse PCB option, air flow can be altered for use in high ceilings.
Ideal Compact SizeThe Mini 4Way cassette air conditioner can be installed in one standard ceilingtile (600Wx600H) so construction or alterations to the ceiling are unnecessary.
3~3.5m 2.7m
High Ceiling
On : Increased fan speed Off : Standard fan speed
Unit : mm
Standard Ceiling
PMSMA
28292009 Samsung Ceiling Air Conditioners
Optional Accessories
Panel
Specification | Mini 4Way Cassette
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
TH026EAV1UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
990/2,600/3,500980/3,300/4,600260/730/1,100240/900/1,400
3.56(A)3.67(A)
1.6/3.4/5.11.5/4.3/6.66.35(1/4)9.52(3/8)
1/220-240/50
TH026EAV1PMSMA
TURBO FAN11.0
575X260X575660X310X635
17/20670X35X670717X93X717
2.6/4.230/25
DEFAULT
UH026EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950 201550
TH035EAV1UH035EAV1
990/3,500/4,200980/4,000/5,000260/1,090/1,400250/1,100/1,400
3.21(A)3.64(A)
1.6/5.0/6.41.5/5.1/6.76.35(1/4)9.52(3/8)
1/220-240/50
TH035EAV1PMSMA
TURBO FAN12.0
575X260X575660X310X635
17/20670X35X670717X93X717
2.6/4.234/27
DEFAULT
UH035EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950 201550
TH052EAV1UH052EAV1
1,050/4,700/6,3001,300/5,500/8,600420/1,460/2,150350/1,590/2,950
3.22(A)3.46(B)
2.4/7.0/10.02.6/8.0/15.0
6.35(1/4)12.7(1/2)
1/220-240/50
TH052EAV1PMSMA
TURBO FAN12.9
575X260X575660X310X635
17/20670X35X670717X93X717
2.6/4.241/33
DEFAULT
UH052EAV1TWIN BLDC
R410A880X638X310
1,023X704X41350/53
49-15~43-20~241,450
5030530
TH060EAV1UH060EAV1
1,800/5,800/6,5001,800/7,000/10,000
520/1,930/2,050470/2,180/3,600
3.01(B)3.21(C)
2.6/8.8/9.42.4/10.0/16.0
6.35(1/4)15.88(5/8)
1/220-240/50
TH060EAV1PMSMA
TURBO FAN13.6
575X260X575660X310X635
17/20670X35X670717X93X717
2.6/4.241/33
DEFAULT
UH060EAV1TWIN BLDC
R410A880X798X310
1,038X861X41357/61
52-15~43-20~241,900
5030530
MR-CH01MWR-TH01 MWR-SH00
Individual Controllers
MWR-WS00MWR-WE00
Indoor Unit
Outdoor Unit
2Way CassetteAir coming out from two sides together with its size can be a perfect fit for long and narrow places withlimited installation space.
QUICK CONNECTION OF DRAIN PIPE
HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK
Small Size Big PerformanceThe 2Way cassette air conditioner is now 45% smaller thancompetitor’s models, so it's even easier to incorporate intobuilding design.
Twin Cross Flow FanThe 2Way cassette type unit is perfect fit for long and narrowrectangular type of space. Twin Cross Flow Fan inside of the2Way cassette will spread cool or warm air even further andwider with less noise.
Standard Formula for Easy InstallationThe dimensions of the 2Way cassette air conditioner allows for easyinstallation into standard ceiling grids (600Wx600H), so everythingjust falls into place.
230mm
890mm575mm
45%Decreased
305mm
1,180mm600mm
600mm
600mm
Cross flow fans
P2SMA
30312009 Samsung Ceiling Air Conditioners
Optional Accessories
Panel
Specification | 2Way Cassette
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
GH052EAMGUH052EAMCModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
5,5006,0001,7001,8003.24(A) 3.33(C)
7.57.9
6.35(1/4)12.7(1/2)
1/220-240/50
GH052EAMGP2SMA
CROSS FLOW FAN14
890X230X5751,107X299X642
21/251,180X20X4601,259X144X539
3.5/6.236/28
DEFAULT
UH052EAMCROTARYR410A
880x648x3101,023X744X413
59/6649
-5~43-5~241,500
30157.525
GH070EAMGUH070EAM1C
7,0007,7002,3502,500
2.98(C)3.08(D)
10.511
6.35(1/4)15.88(5/8)
1/220-240/50
GH070EAMGP2SMA
CROSS FLOW FAN14
890X230X5751,107X299X642
22/261,180X20X4601,259X144X539
3.5/6.238/28
DEFAULT
UH070EAM1CROTARYR410A
880x648x3101,023X744X413
60/6751
-5~43-5~241,700
30157.540
Individual Controllers
Indoor Unit
Outdoor Unit
MR-CH01MWR-TH01 MWR-SH00MWR-WS00MWR-WE00
Duct type Air conditionersWith the widest range of products, Samsung’s duct type air conditioners are perfect for any space withits slim size that offers flexible installation option. The smart pressure control system gives silent operation so that the air conditioning never becomes a distraction.
Clean Filter SystemThe anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air. You deserve to breathe fresh air everyday.
Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles,but suppresses proliferation of molds and bacteria.
BACTERIABACTERIABACTERIABACTERIA Easy Filter CleaningAfter 1,000 hours of operation the filter cleanindicator will inform you that the filter should becleaned. The filter can be easily removed fromthe bottom, left, or right of the unit. (1,000 hoursis the default set time, which can be adjusted to2,000 hours on the internal PCB.)
High Lift-up Drain Pump (optional)The lift-up drain pump lifts condensed water up to 750mm, compared to the competitor’s 700mm, allowing for flexible and convenient installation.
HIGHHIGHHIGHHIGH
Smart Pressure ControlThe Smart Pressure Control System adjusts fan speed according toE.S.P(External Static Pressure), so the air conditioner always givesyou consistent cooling and heating power regardless of the surrounding environment.
E.S.P Control
Air v
olum
e
Static pressure (mmAq)Minimum Maximum
H
H
M
M
L
L
WiredWiredWiredWired Wired Remote ControllerWired remote controller is included for more convenient use of the air conditioner.
32332009 Samsung Ceiling Air Conditioners
Slim DesignOnly 199mm thick, this slim design makes installation, maintenance,and repair easy.
Easy to MaintainParts are easily accessible bysimply opening the bottompanel, which reduces timeand maintenance costs.
199mm
199mm
220mm
225mm
160 180 200 220210 230
ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER CLEANING
HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURECONTROL
Flexible InstallationThe air inlet can be set up on either the bottomor rear of the unit, so there is more flexibility ininstallation.
Rear side air inlet Bottom side air inlet
Suction Duct Suction Duct
TexTex
Diffuser Diffuser
Slim DuctSlim duct type indoor units with industry leading compact size gives flexible installation and easier maintenance options.
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
EH035EAV1UH035EAV1980/3,500/4,200980/4,000/5,200260/1,150/1,400210/1,105/1,700
3.04(B)3.62(A)
1.7/5.3/6.41.3/5.1/7.96.35(1/4)9.52(3/8)
1/220-240/50
EH035EAV1-
SIROCCO FAN11.00/2/4
990X199X6001,133X333X722
26/31---
32/27MDP-E075SEE
DEFAULT
UH035EAV1SINGLE BLDC
R410A790X548X285938X610X382
35.5/3847
-10~43-15~24
950 201550
EH052EAV1UH052EAV1
1,700/5,000/6,0001,500/6,000/8,000420/1,550/1,950360/1,650/2,700
3.23(A)3.64(A)
2.5/7.0/8.52.1/7.5/12.0
6.35(1/4)12.7(1/2)
1/220-240/50
EH052EAV1-
SIROCCO FAN16.50/2/4
1,100X199X6001,330X330X730
31/39---
33/30MDP-E075SEE
DEFAULT
UH052EAV1TWIN BLDC
R410A880X638X310
1,023X704X41350/53
49-15~43-20~241,450
5030530
EH070EAV1UH070EAV1
2,200/7,100/8,0002,000/8,000/12,000
570/2,200/2,650500/2,150/3,800
3.23(A)3.72(A)
2.9/10.0/12.02.8/10.0/16.5
6.35(1/4)15.88(5/8)
1/220-240/50
EH070EAV1-
SIROCCO FAN19.60/2/4
1,100X199X6001,330X330X730
31/39---
36/32MDP-E075SEE
DEFAULT
UH070EAV1TWIN BLDC
R410A880X798X310
1,038X861X41357/61
52-15~43-20~241,900
5030530
EH052EAMCUH052EAMC
5,5006,3001,9502,0002.82 3.15 9.00 9.00
6.35(1/4)12.7(1/2)
1/220-240/50
EH052EAMC-
SIROCCO FAN14.90/2/4
900X199X6001,124X315X713
26/30---
33/30MDP-E075SEE
DEFAULT
UH052EAMCROTARYR410A
880X648X3101,023X704X413
59/6649
-5~43-5~241,500
30157.540
EH070EAM1CUH070EAM1C
6,8007,5002,4202,4202.81 3.10 11.10 11.10
6.35(1/4)15.88(5/8)
1/220-240/50
EH070EAM1C-
SIROCCO FAN20.50/2/4
1,100X199X6001,330X330X730
30.5/38.5---
36/32MDP-E075SEE
DEFAULT
UH070EAM1CROTARYR410A
880X648X3101,023X704X413
60/6751
-5~43-5~241,700
30157.540
WIRED REMOTE CONTROLLERWiredWiredWiredWired
Drain Pump
MDP-E075SEE / MDP-E075SEE1
Indoor Unit
Outdoor Unit
34352009 Samsung Ceiling Air Conditioners
Optional Accessories
Specification | Slim Duct
Individual Controllers
MR-CH01MWR-TH01MWR-WS00MWR-WE00
ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA
EASY FILTER CLEANING
HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH
SMART PRESSURECONTROL
MSP DuctFlexible installation options offer a variety of solutions for different shapes of room, and the smart pressure controlsystem provides quiet operation.
WIRED REMOTE CONTROLLERWiredWiredWiredWired
Flexible InstallationSamsung's MSP Duct air conditioners offer different solutionsfor any shape room allowing for specific airflow requirements.
L-shaped area Y-shaped areaAreas far apart
Silent Operation with the static pressure controlThe external static pressure control makes it easy to design duct work to ensure efficiency and silent operation.
Narrow Width (5.2kW) Middle Static Pressure
900mm Slim DuctmmAq
2
4
6
8
10
MSP Duct
0~10mmAq
0~6mmAq
Width measured without control box.
Easy to MaintainReduce time and maintenance costsby keeping parts easily accessible.
R-Inverter
36372009 Samsung Ceiling Air Conditioners
Drain Pump
MDP-M075SGU1 / MDP-M075SGU2 / MDP-M075SGU3
Optional Accessories
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
DH052EASUH052EAS
1,600/5,000/6,0001,500/6,000/9,000540/1,550/1,950500/1,750/3,000
3.23(A)3.43(B)
2.7/7.1/8.72.5/8.0/13.5
6.35(1/4)12.70(1/2)
1/220-240/50
DH052EAS-
SIROCCO FAN16.50/4/6
900X260X4801,146X363X584
29.5/34.5---
37/33MDP-M075SGU3
DEFAULT
UH052EASTWIN BLDC
R410A880X638X310
1,023X704X41350/53
49-10~43-15~241,350
3020520
DH070EASUH070EAS
2,200/7,100/8,0001,900/8,000/10,500
700/2,720/3,070620/2,490/3,670
2.61(D)3.21(C)
3.1/12.4/13.72.71/11.4/16.3
6.35(1/4)15.88(5/8)
1/220-240/50
DH070EAS-
SIROCCO FAN21
0/4/6900X260X480
1,146X363X58429.5/34.5
---
38/34MDP-M075SGU3
DEFAULT
UH070EASTWIN BLDC
R410A880X638X310
1,023X704X41350/53
52-10~43-15~241,350
3020530
DH090EASUH090EAS
3,100/9,000/10,0002,900/9,500,/13,000
850/3,200/3,600680/2,960/4,650
2.81(C)3.21(C)
3.82/14.0/15.83.1/13.0/20.5
9.52(3/8)15.88(5/8)
1/220-240/50
DH090EAS-
SIROCCO FAN24
0/6/81,150X260X4801,390x345x575
33/40---
39/35MDP-M075SGU1
DEFAULT
UH090EASTWIN BLDC
R410A880x950x320
1,043x1,062x41178/85
52-15~50-20~242,400
7530555
DH105EASUH105EAS
3,000/10,500/12,0003,300/11,200/13,700
840/3,730/4,400760/3,720/5,000
2.81(C)3.01(D)
3.6/16.5/18.53.2/16.5/29.0
9.52(3/8)15.88(5/8)
1/220-240/50
DH105EAS-
SIROCCO FAN24
0/6/81,150X260X4801,390X345X575
34/40---
40/33MDP-M075SGU1
DEFAULT
UH105EASTWIN BLDC
R410A932X1,128X375
1,091X1,286X472102/117
56-15~50-20~242,600
75307.540
Indoor Unit
Outdoor Unit
Specification | MSP Duct
MR-CH01MWR-TH01
Individual Controllers
MWR-WS00MWR-WE00
MSP Duct
Specification | MSP Duct
38392009 Samsung Ceiling Air Conditioners
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
DH105EAVUH105EAV
3,350/10,500/12,0002,600/11,200/15,500
830/3,270/3,700740/3,100/5,500
3.21(A)3.61(A)
3.8/14.7/16.84.5/14.1/25.0
9.52(3/8)15.88(5/8)
1/220-240/50
DH105EAV-
SIROCCO FAN28.1
0/8/101,150X320X4801,396X424X584
39/46---
39/35MDP-M075SGU1
DEFAULT
UH105EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472102/117
56-15~50-20~242,800
75307.540
DH105EAVUH105GAV
3,350/10,500/12,0002,600/11,200/15,500
830/3,270/3,700740/3,100/5,500
3.21(A)3.61(A)
1.4/5.0/6.11.3/5.0/8.59.52(3/8)15.88(5/8)
3/380-415/50
DH105EAV-
SIROCCO FAN27.5/28.1
0/8/121,150X320X4801,396X424X584
39/46---
39/35MDP-M075SGU1
DEFAULT
UH105GAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472102/117
56-15~50-20~242,800
75307.540
DH140EAVUH140EAV
3,450/14,000/15,4003,750/16,000/18,5001,110/4,650/5,7001,020/4,430/5,800
3.01(B)3.61(A)
5.0/20.6/23.54.5/19.6/26.5
9.52(3/8)19.05(3/4)
1/220-240/50
DH140EAV-
SIROCCO FAN36.8
0/8/101,200X360X6501,447X425X769
55/60---
43/38MDP-M075SGU2
DEFAULT
UH140EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472105/120
59-15~50-20~243,100
75307.540
DH140EAVUH140GAV
3,450/14,000/15,4003,750/16,000/18,5001,110/4,650/5,7001,020/4,430/5,800
3.01(B)3.61(A)
1.8/7.4/8.81.7/7.0/9.59.52(3/8)19.05(3/4)
3/380-415/50
DH140EAV-
SIROCCO FAN35.6/36.8
0/8/121,200X360X6501,447X425X769
55/60---
43/38MDP-M075SGU2
DEFAULT
UH140GAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472105/120
59-15~50-20~242,800
75307.540
Indoor Unit
Outdoor Unit
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
DH090EAVUH090EAV
3,000/9,000/10,0003,300/9,500/13,500
840/2,800/3,400760/2,780/4,790
3.21(A)3.41(B)
3.5/12.4/15.03.1/12.3/24.5
9.52(3/8)15.88(5/8)
1/220-240/50
DH090EAV-
SIROCCO FAN24
0/6/81,150X260X4801,390X345X575
33/40---
39/35MDP-M075SGU1
DEFAULT
UH090EAVTWIN BLDC
R410A932X1,128X375
1,091X1,286X472102/117
56-15~50-20~242,600
75307.540
DH070EAV1UH070EAV1
2,200/7,100/8,0001,900/8,000/11,000
600/2,210/2,600470/2,210/3,700
3.21(A)3.62(A)
2.9/10.0/12.02.8/10.0/16.5
6.35(1/4)15.88(5/8)
1/220-240/50
DH070EAV1-
SIROCCO FAN19.60/4/8
1,150X260X4801,390X345X575
34/40---
39/35MDP-M075SGU1
DEFAULT
UH070EAV1TWIN BLDC
R410A880X798X310
1,038X861X40657/61
52-15~43-20~241,900
5030530
DH052EAV1UH052EAV1
1,700/5,000/60,001,700/6,000/8,300550/1,560/1,950480/1,760/2,750
3.21(A)3.41(B)
3.1/7.5/9.32.6/8.4/13.1
6.35(1/4)12.7(1/2)
1/220-240/50
DH052EAV1-
SIROCCO FAN16.50/4/6
900X260X4801,146X363X584
29.5/34.5---
37/33MDP-M075SGU3
DEFAULT
UH052EAV1TWIN BLDC
R410A880X638X310
1,023X704X41350/53
49-15~43-20~241,450
5030530
Indoor Unit
Outdoor Unit
MSP Duct 40412009 Samsung Ceiling Air Conditioners
Specification | MSP Duct
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
DH094EAMCUH094EAM1C
8,800 9,5003,6503,5002.41(E) 2.71(E)16.515.5
9.52(3/8)15.88(5/8)
1/220-240/50
DH094EAMC-
SIROCCO FAN24.40/6/8
1,150X260X4801,390X345X575
34.5/40---
39/35MDP-M075SGU1
DEFAULT
UH094EAM1CROTARYR410A
880X798X3101,023X891X413
74/8255
-5~43-5~241,800
30157.540
DH105EAMCUH105EAMC
10,00011,0003,8303,850
2.61(D) 2.86(D) 17.50 17.50
9.52(3/8)19.05(3/4)
1/220-240/50
DH105EAMC-
SIROCCO FAN30
0/8/101,150X320X4801,396X424X584
39/46---
39/35MDP-M075SGU1
DEFAULT
UH105EAMCSCROLLR410A
880X931X3201,043X411X1,062
87/9256
-5~43-5~242,600
50307.540
Indoor Unit
Outdoor Unit
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current (Min./Standard/Max.)
Piping Connection
Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set
Panel
Sound Pressure Level 3)
Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmAqmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
DH105EAMCUH105GAMC
10,00010,7003,7003,800
2.70(D) 2.82(D)
6.40 6.50
9.52(3/8)19.05(3/4)
3/380~415/50
DH105EAMC-
SIROCCO FAN30
0/8/101,150X320X4801,396X424X584
39/46---
39/35MDP-M075SGU1
DEFAULT
UH105GAMCSCROLLR410A
880X931X3201,043X411X1,062
87/9256
-5~43-5~242,750
50307.540
DH140EAMCUH140GAMC
14,70016,0005,5005,700
2.67(D) 2.81(D)
9.50 10.20
9.52(3/8)19.05(3/4)
3/380~415/50
DH140EAMC-
SIROCCO FAN38
0/8/151,200X360X6501,447X425X769
52/60---
43/38MDP-M075SGU2
DEFAULT
UH140GAMCSCROLLR410A
932X1,128X3751,091X1,286X472
121/13659
-5 ~ 43-5 ~ 243,300
50307.540
Indoor Unit
Outdoor Unit
Floor & Convertible type Air conditionersConvertible installation options, and the unique but functional design adds aestheticatmosphere to your interior while giving efficient cooling and heating.
I Interior DesignNow with more flexibility in placement, the air conditionercan add a stylish element to your room.
INTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN
Silent ModeIndoor units operate quietly with the leastpossible noise.
Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, butsuppresses proliferation of molds and bacteria.
BACTERIABACTERIABACTERIABACTERIA
Light Weight UnitThis extremely lightweight design makes maintenanceand installation easy.
LIGHTLIGHTLIGHTLIGHT
Flexible Pipe InstallationThe drain pipe can be installed in 6 different places, so youhave more options in where to place your air conditioner.
Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
Auto ChangeoverThe Auto Changeover automatically selects the operationmode according to the temperature setting.
AUTOAUTOAUTOAUTO
Auto Changeover
42432009 Samsung Ceiling Air Conditioners
MPI ZoneSamsung's Micro Plasma Ion Zone is a technology that generatesactivated hydrogen and oxygen ions, which exterminates virusesand allergy-causing microbes in the air by neutralizing them andturning into water.
ConsoleUnique design with the two air outlets on top and bottom side of the indoor unit provide more efficientcooling and heating.
Optional Accessories
Elegant Design
Clean PanelStay clean with the smartly designed CleanPanel. This unique panel keeps dust frombeing accumulated so the unit and the roomstays cleaner.
Slim DesignIt can't get any slimmer. This newly introducedconsole type air conditioner is only 199mmthick, the slimmest on the market. Its slimdesign easily integrates the unit into yourdecor.
Silent Operation (23dB)The silent, yet powerful and efficient cooling and heating systemkeeps things more comfortable. Silent mode is available in 4 different operating modes: High / Medium / Low / Silence.
2Way air outletsThere are two separate air outlets for cooling and heating. Havingwarmer air coming out from the bottom part of the air outlet willspread the warm air evenly throughout the room. Stay cooler andwarmer in every corner of your room.
Slim & Smart DesignThis extremely slim design with Clean Panel adds aesthetic value to any interior.
199mm
Black DisplayFunctional art, the touch screen display iselegant while it maximizes the convenienceof control.
INTERIORDESIGNINTERIORINTERIOR
DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN
ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT UNIT
LIGHTLIGHTLIGHTLIGHT
SILENT MODE
FLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe
InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless
AUTOCHANGEOVERAUTOAUTOAUTOAUTO
44452009 Samsung Ceiling Air Conditioners
MWR-TH01
Individual Controllers
MWR-WS00MWR-WE00
Standard Accessories
Wireless RemoteControllers
Console
Specification | Console
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor Filter(Catechin, Deodorizing)Outdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
JH026EAV1UH026EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
980/2,600/3,600950/3,500/4,600230/670/1,040210/970/1,250
3.88(A)3.61(A)
1.5/3.3/4.91.4/4.7/6.26.35(1/4)9.52(3/8)
1/220~240/50
JH026EAV1-
TURBO FAN8.1
720X620X199810X710X295
15.2/20.3---
38/23DEFAULT
UH026EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950201550
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor Filter(Catechin, Deodorizing)Outdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unitModel
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
JH035EAV1UH035EAV1
990/3,500/4,200990/4,000/4,900250/1,190/1,340210/1,108/1,350
3.21(A)3.61(A)
1.7/5.2/6.21.4/5.3/6.56.35(1/4)9.52(3/8)
1/220~240/50
JH035EAV1-
TURBO FAN9
720X620X199810X710X295
15.2/20.3---
39/24DEFAULT
UH035EAV1SINGLE BLDC
R410A790X548X285938X610X382
32.6/35.447
-10~43-15~24
950201550
JH052EAV1UH052EAV1
1,200/5,000/6,0001,400/5,600/8,200390/1,560/2,030330/1,553/2,900
3.21(A)3.61(A)
2.0/7.8/9.21.7/7.8/13.0
6.35(1/4)12.7(1/2)
1/220~240/50
JH052EAV1-
TURBO FAN11.5
720x620x199810x710x295
16/20.3---
44/25DEFAULT
UH052EAV1SINGLE BLDC
R410A880X638X310
1,023X704X41352/56
49-15~43-20~241,450
5030530
46472009 Samsung Ceiling Air Conditioners
Indoor Unit
Outdoor Unit
Indoor Unit
Outdoor Unit
CeilingTwo way installation options allow the air coming out from the ceiling or floor.
INTERIORDESIGNINTERIORINTERIOR
DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN
ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA
LIGHT WEIGHT UNIT
LIGHTLIGHTLIGHTLIGHT FLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe
InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless
AUTOCHANGEOVERAUTOAUTOAUTOAUTO
Compact but PowerfulSamsung’s ceiling type air conditioner boasts a slim, compactdesign, half the size of its competitors, with cooling powercomparable to competitor’s larger products.
2way InstallationDepending on the space availability and the purposeof the air conditioner, the indoor unit can be installedunder the ceiling or on the floor.
Under Ceiling Floor Standing
48492009 Samsung Ceiling Air Conditioners
Optional Accessories
MWR-WS00 MWR-TH01
Individual Controllers
MR-CH01
Specification | Ceiling
Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Dimension (Net)Dimension (Gross)Weight (Net/Gross)
Capacity (Min./Standard/Max.)
Power Input (Min./Standard/Max.)
E.E.R
Running Current(Min./Standard/Max.)Piping Connection
Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet
Panel
Sound Pressure Level 3)
Indoor FilterOutdoor UnitModelCompressorRefrigerantSet
Sound Pressure LevelTemperature Range
Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.
Cooling 1)
Heating 2)
CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas
WxHxDWxHxD
WxHxDWxHxD
High/Low
TypeWxHxDWxHxD
CoolingHeating
Indoor unitOutdoor unit
FH052EAV1UH052EAV1Model
Notes
1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m
3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.
- Specifications are subject to change without prior notice for product improvement.
WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz
m3/minmmmmkgmmmmkgdB(A)
mmmmkgdB(A)°C°Cgmmmg/m
1,700/5,000/5,6001,700/6,000/8,000480/1,660/1,900430/1870/3050
3.01(B)3.21(C)
2.8/7.8/9.02.4/8.8/14.5
6.35(1/4)12.7(1/2)
1/220-240/50
FH052EAV1-
SIROCCO FAN14.5
1,000X200X6501,074X294X726
22/26---
38/32DEFAULT
UH052EAV1TWIN BLDC
R410A880X638X310
1,023X704X41350/54
49-15~43-20~241,450
5030530
FH070EAV1UH070EAV1
2,000/7,100/8,0002,000/8,000/11,000
590/2,520/2,900450/2,750/3,750
2.81(C)2.91(D)
3.0/11.0/13.02.9/12.5/17.0
6.35(1/4)15.88(5/8)
1/220-240/50
FH070EAV1-
SIROCCO FAN16.0
1,000X200X6501,074X294X726
22/26---
41/36DEFAULT
UH070EAV1TWIN BLDC
R410A880X798X310
1,038X861X41357/63
52-15~43-20~241,900
5030530
FH052EAMCUH052EAMC
5,4006,2001,9202,000
2.61(D)3.10(D)
8.5 8.6
6.35(1/4)12.7(1/2)
1/220-240/50
FH052EAMC-
SIROCCO FAN13.2
1,000X200X6501,074X294X726
22/26---
38/32DEFAULT
UH052EAMCROTARYR410A
880X648X3101,023X744X413
59/6649
-5~43-5~241,500
30157.525
FH070EAM1CUH070EAM1C
6,7007,2002,4802,550
2.70(D)2.82(D)
11.4 11.5
6.35(1/4)15.88(5/8)
1/220-240/50
FH070EAM1C-
SIROCCO FAN14.4
1,000X200X6501,074X294X726
22/26---
41/36DEFAULT
UH070EAM1CROTARYR410A
880X648X3101023X744X413
60/6751
-5~43-5~241,700
30157.540
200%
100%
136%
118% 123%
100%
Size
7.0kW Model
Weight
Smaller Lighter
Indoor Unit
Outdoor Unit
MDP-E075SEEMDP-E075SEE1MDP-M075SGU3MDP-M075SGU1MDP-M075SGU2
Slim duct
MSP duct
PVC Hose, 2.6kW~7.0kWNew Hose, 10.5kW~14.0kW5.2kW~7.0kW9.4kW~12.5kW14.0kW~17.5kW
Duct Drain Pump
ModelClassification Compatible units Description
PSSMA
P2SMA
PMSMA
P4SMA
Unified Panel
Unified Panel
Unified Panel
Unified Panel
Single, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
Single, Multi, DVM unified Panel
Slim 1Way Cassette
2Way Cassette
Mini 4Way Cassette
4Way Cassette
ModelClassification Compatible units Description
Drain Pump
Panel
MWR-WE00
MWR-WS00
MWR-TH01
MR-CH01
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
Unified Remote Controller
Individual and group control
Individual and group control
Individual and group control
Simple schedule control
Wired Remote Controller
Wireless Remote Controller
ModelClassification Compatible units Description
Remote Controller
50512009 Samsung Ceiling Air Conditioners
Accessories
CONTROL SYSTEMS02
52532009 Samsung Ceiling Air Conditioners
Power of control, within your handsSamsung’s smart control system is the most convenient way
to control your system air conditioner. Control systems have
improved one step forward for better usability and
management for you to be able to control your air
conditioner practically anywhere and anytime.
| Control Systems
54
56
58
62
63
64
| Individual Control System
| Centralized Control System
| Integrated Management System
| Guest Room Management System
| DVM Pro
| Accessories
Individual Control SystemErgonomic and innovative remote controllers feature better design, easy grip, large and soft
buttons with easy-to-view displays.
Function Icon
ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAYErrorErrorErrorError
FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter
MWR-WS00 (Premium)• Weekly schedule setting
(Maximum 70 schedules)• Exception date setting• Built-in room temperature
sensor• Clear and bright screen with
LCD backlight• Temperature limit setting• Wireless remote control
restriction• Automatic Stop mode • Sleep and Silent mode• Child lock
Wired Remote Controller
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
MR-CH01
• Simple schedule control• Wide display• Soft touch button
Wireless Remote Controller
OperationOperationOperationOperation FilterFilterFilterFilter
54552009 Samsung Ceiling Air Conditioners
MWR-TH01• Simple schedule control
• Wireless remote controlrestriction
OperationOperationOperationOperation GroupGroupGroupGroup
ErrorErrorErrorError FilterFilterFilterFilter
MWR-WE00 (Multi function)• Unified controller
(A/C, ERV, A/C+ERV)• Different button permission
levels• Weekly schedule setting
(A/C, ERV, A/C+ERV)• Exception date setting• Built-in room temperature
sensor• Clear and bright screen
with LCD backlight• Wireless remote control
restriction• Automatic Stop mode • Sleep and Silent mode• Child lock
56572009 Samsung Ceiling Air Conditioners
Centralized Control SystemSamsung's centralized control system can control and monitor up to 4,096 individual indoor units and 256 groupsof indoor units simultaneously with great convenience and efficiency.
Function Icon
ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING
OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAYErrorErrorErrorError
FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter
MCM-A202A• Maximum 16 group controls (Maximum 256 Indoor units)
• Unified/Individual indoor unit control (On/Off)
• Wireless/wired remote control restriction
• Cooling/Heating mode control
• Indoor unit error display
Centralized Controller
MCM-A100
Function Controller
OperationOperationOperationOperation ErrorErrorErrorError FilterFilterFilterFilter
• Control and monitoring ofup to 16 indoor unit groups
To use Function Controller, itrequires to be connected toMCM-A202A
• Communicator betweenindoor/outdoor units and the centralized controller
Interface ModuleMIM-B04A
Integrated Management SystemIntegrated Management System is convenient for managing system air conditioners installed in small and middle-sizedbuildings. It can be managed through the Internet so you can control the air conditioners from anywhere.
Data Management Server
DMS System
Max. 16 units
DMS
58592009 Samsung Ceiling Air Conditioners
Web Server Function• Built-in web server.
• Multiple upper-layer control access with prioritized management.
• Remote access control with the static IP address.Internet
Anytime, Anywhere Control
Cooling Schedule Setup
Power Distribution System• Power distribution to up to 256 indoor units.
• Data query for watt-hour, use time and use ratio.
• File save in Microsoft Excel format.
• 93 days worth of power distribution data storage.
08:00 AM On 10:00 PM Off
External Contact Interface• Full indoor unit control with simple contact input.
(Emergency/Lock)
• State output (Operation/Error) for synchronous
control.
Schedule Control Function• Up to 256 schedule settings.
• Weekly, Daily or 1-Day schedule control.
• Exception date setting.
History Management• Easy service and management with error history.
• Occurrence date, error details, current state.
Building Control System
Rapid Service Response
Error History Monitoring
Fire Control System Error Status Indicator
Operation Restriction
Service
Easy Control & Monitoring• Individual/Group control and monitoring of up to 256 indoor units.
• Operation mode, temperature setting, airflow direction and
fan speed.
• Easy multiple/full indoor unit selection.
• Full room temperature display.
• Error history query based on date.
Enhanced central management• Operation mode lock
• Temperature limit setting
• Wireless / wired remote control restriction
DMS
Easy Control & Monitoring
Web Server Function
Schedule Control Function
Power Distribution System
Building Management System
MIM-D00• Built-in web server for PC-independent management and remote access
control• Multiple upper-layer control access (S-NET 3, S-NET Mini, Web-client)• Individual/Group control of up to 256 indoor units and heat exchange units• Error history management• Weekly/Daily schedule control• Power distribution function• 2 digital inputs, 2 digital outputs• Current time management even during power failure (for 24 hours)• Data storage in non-volatile memory • Emergency stop function with simple contact interface• Operation mode lock• Temperature limit setting
360kWh
460kWh
140kWh
Indoor unit operation state
1. Operation data accumulation andpower distribution
2.Data extract - Excel format
610kWh
180kWh
5th Floor
4th Floor
3rd Floor
2nd Floor
1st Floor
Integrated Management SystemYou can manage a group of buildings with S-NET3 through Data Management Servers that manage each of thebuildings. S-NET3 provides flexible and complete control for a great variety of applications.
• Fully integrated PC management software.
• Up to 16 DMSs connection through the Ethernet.
• Central management of up to 4,096 indoor/heatexchange units.
• Schedule/Zone control.
• Error/Operation history management.
• Power distribution management and analysis.
• Automatic update through the Internet.
S-NET 3
Data Management Server
S-NET 3 System
S-NET 3
Supports 16 DMSs
Max. 16 units
S-NET mini System
• Dynamic compatibility options (DMS, centralized controller, interface module)
• Control and monitoring of up to 256 indoor units• Detailed cycling information monitoring• Schedule function (Weekly, Daily)• USB keyboard support • Error display • 7-inch wide LCD display • Temperature limit setting • Touch screen• Zone control• Child-lock setting• Operation mode lock• External contact control
S-NET mini
Supports 16
InterfaceModules
Supports 16
CentralizedControllers
Supports 4 DMSs
60612009 Samsung Ceiling Air Conditioners
Guest Room Management SystemThe Guest Room Management System is a smart way to save energy and money. When the Key Tag is in place, the airconditioner is activated. When the Key Tag is removed, the air conditioner switches off. Now you can avoid cooling anunoccupied room and save energy.
MIM-B14• Direct indoor unit control by external contact signal
• Window-synchronized indoor unit control
• Emergency control with simple contact input
• Indoor unit operation/error state output through relay contacts
62632009 Samsung Ceiling Air Conditioners
Key-Tag
On/Off
Window OpenSensor
MalfunctionAlarm
External deviceControl
On/Off On/OffError
Example
DVM - Pro(DVM, FJM, CAC Equipment Selection Software)
DVM-Pro consists of two kinds of software called DVM-Pro Sales and CAD mode.
DVM-Pro Sales mode• Workspace: Creation ‘Project’ & ‚‘Workspace (DVM, FJM, CAC)’
• Indoor Unit: Indoor unit and accessory selection
• Outdoor Unit: Automatic selection and capacity simulation
• Piping: Basic, standard or manual selection with system check
• Wiring: Automatic diagram with communication wiring of indoor/outdoor/control units and electric power meters
• Control system: Automatic control unit selection
• Report: Specifications, diagrams and quotation
Download!www.dvmsystem.com Download Center DVM-Pro
DVM-Pro CAD mode• Quick, easy, precise design
• Compatibility with AutoCAD
• Automatic calculation: Refrigerant & drain pipe size
• Automatic selection: Refnet joint, header & distributor kit
• System check: Installation regulation & refrigerant addition
• Simulation: System capacities
• Easy control system selection
• Automatic report: Piping installation diagram, equipment list & quotation
Contact to Samsung HQ or Distributors for DVM-Pro CAD!
64652009 Samsung Ceiling Air Conditioners
AccessoriesClassification Product Model Image Application Model
IntegratedManagementSystem
ControllerDMS MIM-D00 CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series
S-NET 3 MST-P3P
S-NET Mini MST-S3W
CentralizedControlSystem
InterfaceModule
CAC, FJM, DVM Series, ERV
CAC, FJM, DVM Series
CAC, DVM, DVM PLUS, DVM HR
MCM-A202AController Centralized Controller
MCM-A100Function Controller
MIM-B04ACentralized Control Interface Module
CAC, DVM Plus II, DVM Plus III, DVM Plus II HR, DVM Plus III HR, Mini DVM (R410A), FJM(Non MH FKEA)
External Contact Interface Module MIM-B14Guest RoomManagementSystem
IndividualControlSystem
ControllerWireless Remote Controller MR-CH01 Cassette, Wall Mounted,
Ceiling, Duct (Receiver needed),Console
Cassette, Wall Mounted, Ceiling, Duct, Console
Cassette, Wall Mounted, Ceiling, Duct, Console
Duct (For Wireless Remote Controller)
Duct (For Wireless Remote Controller)
Cassette, Wall Mounted, Ceiling, Duct, Console
Wired Remote Controller (Premium) MWR-WS00
Wired Remote Controller MWR-TH01
DuctReceiver Kit ofWireless RemoteController
MRK-A00ReceiverofWireless Remote Controller
Receiver Wire MRW-10A
7-day Scheduler MWR-BS00
Cassette, Wall Mounted, Ceiling, Duct, Console
Wired Remote Controller (Multi Function) MWR-WE00
DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM HR II, DVM PLUS III, DVM PLUS IIIHR
Icon IndexCassette Type Icon
WIDE BLADEWider blades provide moreeven cooling power. WIDEWIDEWIDEWIDE
CEILING SOILINGPREVENTIONNewly designed panel preventsceiling contamination.
HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.
FRESH AIR INTAKE
Optional air intake motorbrings in fresh air from outside.
HIGHHIGHHIGHHIGH
FRESHFRESHFRESHFRESH
QUICK CONNECTIONOF DRAIN PIPEUnique drain pipe connectionis easy to install.
QUICKQUICKQUICKQUICK
SUB DUCT
The Sub Duct makes it easyto provide air conditioning toa nearby smaller space.
SUB DUCTSUB DUCTSUB DUCTSUB DUCT
Duct Type Icon
ANTI-BACTERIA FILTERAnti-bacteria Filter traps dust particles and suppresses proliferationof molds and bacteria.
EASY FILTER CLEANINGFilter cleaning indicator willlet you know when the filterneeds to be cleaned.
HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.
SMART PRESSURE CONTROLAdjusts fan speed to provideconstant cooling and heatingperformance.
BACTERIABACTERIABACTERIABACTERIAHIGHHIGHHIGHHIGH
WIRED REMOTE CONTROLLERDefault wired remote controlleris provided.
WiredWiredWiredWired
Control Systems Icon
Floor & Convertible Type Icon
INTERIOR DESIGNThe clean, modern designcomplements any decor.
LIGHT WEIGHT UNITExtremely lightweight, so maintenance and installation is easy.
ANTI-BACTERIA FILTERAnti-bacteria Filter traps dustparticles and suppresses proliferation of molds and bacteria.
INTERIORINTERIORDESIGNDESIGN
INTERIORINTERIORDESIGNDESIGN BACTERIABACTERIABACTERIABACTERIA
AUTO CHANGEOVERAutomatically changes operationmode according to temperaturesetting.
AUTOAUTOAUTOAUTO
LIGHTLIGHTLIGHTLIGHT
FLEXIBLE PIPEINSTALLATIONThe pipe can be installedin 6 different places formore placement options.
SILENT MODEIndoor and outdoor unitoperates silently.
Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation
WIRELESS REMOTECONTOLLERDefault wireless remote controlleris provided.
WirelessWirelessWirelessWireless
ON/OFF, OPERATION MODE,FAN SPEED, AIR FLOW, TEMPERATURE SETTING
OperationOperationOperationOperation INDIVIDUAL AND GROUPCONTROL (MAXIMUM 16INDOOR UNITS)
GroupGroupGroupGroup
ERROR DISPLAYErrorErrorErrorError FILTER REPLACEMENT
ALARM RESET
FilterFilterFilterFilter