33
Samsung Electronics Co., LTD. Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742 www.dvmsystem.com Version.1 When a single air conditioner creates the perfect coolness Imagination Lives Experience this year’s Ceiling air conditioners, with the style and the functionality. Space for Partnership CAC 2009 SAMSUNG System Air Conditioner

2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

  • Upload
    votruc

  • View
    216

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Samsung Electronics Co., LTD.Head Office (Suwon Korea) 416, Maetan-3Dong, Yeongtong-Gu, Suwon City, Gyeonggi-Do, Korea 443-742www.dvmsystem.com Version.1

When a single air conditioner creates the perfect coolness Imagination Lives

Experience this year’s Ceiling air

conditioners, with the style and

the functionality.

Space for Partnership

CAC2009

SAMSUNGSystem Air Conditioner

Page 2: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Perfect fit for every spaceA perfect air conditioner is different, it depends on the application and end user. Each building and

space has different objectives and different people inside. Perfect fit, Samsung Commercial Air

Conditioners were designed as if it was customized to fit in to your interior design. Slim and

compact, with aerodynamically designed parts will deliver the cool air with style.

SAMSUNG ELECTRONICS HOME APPLIANCE PRODUCT AWARDSTechnology can contribute to the development of a greener, cleaner world andincrease quality of life. This is a philosophy we have held at Samsung for over 30years. Ever since its establishment in 1973, Samsung Electronics has concentrated on developing environmentally friendly products and has convergedincreasingly sophisticated digital technology with its appliance products to attain astrong technological advantage in improving consumers' quality of living with the ultimate in convenience and style.

Page 3: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Big Confidence Global Leading

Company >> SAMSUNGSince day one, Samsung Electronics has committed itself to becoming a leader in every facet of its market initiatives. The result is the growth of a brand that’s synonymous with impeccable standards, high quality products,and an unwavering dedication to the customer. Through continuous creativity and the development of highlyinnovative products, Samsung has captured the hearts and minds of customers worldwide, which will propel ourcompany and our brand well into the future.

SAMSUNG’S BRAND VALUEIn the Digital era, products are being distinguished by their

brand in addition to their functions or quality. In 1999 Samsung

Electronics has implemented its global brand communication

strategy. Since then, based on the research conducted by

Interbrand INC., USA, Samsung Electronics has become one of

the fastest growing brands equities from 6.4 billion USD (2001)

to over 17.7 billion USD (2008) and is now ranked 21st on

Interbrand's Top100 Global Brand List.

Samsung has increased its value by emphasizing technology as

a life innovator. Samsung will remain close to the customer

through its technologies contributing to a higher quality of life.

GLOBAL BUSINESS NETWORKSamsung's thrust on Product Innovation and R&D has given the company a competitive edge in the marketplace. With an

investment of over USD 4.59 billion, Samsung operates 16 R&D centers worldwide and employs 27,000 researchers of which

2,500 hold a Ph. D. As a result, Samsung has already applied for 1600 patents in the USA. The focus of the R&D center is to

customize electronics products to meet the Specific needs of consumers in that region. Samsung R&D Centers are helping the

company to continuously innovate and introduce products customized for today’s global market.

6 Global Operation Centers

10 Global Headquarters

EuropeStuttgart

CIS

Milano

ME Asia Africa

India

SW Asia

SE Asia

Delhi

ChinaKorea

ShanghaiJapan Los Angeles

Mexico

US Chicago

Latin America

Malaysia

Thailand

London

7 Design Centers

5 HA R&D Centers

2009 SAMSUNG Ceiling Air Conditioner

02 | INTRODUCTION 09 | Line-up 12 | S-Inverter Technology

14 | Indoor Units 52 | Control Systems

Page 4: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Four Seasons of HopeSamsung's Four Seasons of Hope is about kids. It's about using the power of our brand to give something back to the

communities we serve.

Samsung's Four Seasons of Hope supports community-based foundations and charities headed by some of this country's

favorite sports legends. Samsung pledges to raise national awareness and funds for these outstanding charities and to

identify how others can also make a difference in the lives of these children and families.

Samsung Recycling DirectSM

All good things come to an end. Let's make sure it's a Green end.As technology continually evolves, so will your digital lifestyle. When you upgrade your consumer electronics, you will need

to recycle your old products responsibly. That's why we're proud to reaffirm our commitment and responsibility to recycle

DirectSM using the new Samsung Recycling program launched on October 1st, 2008.

Thinking of You.

Making industry-leading products is only part of the big picture. Our commitment to creating a better world for futuregenerations is equally as important. We strongly believe that if future generations aren't given the opportunity to succeed, we definitely won't. As a corporate citizen, we have dedicated ourselves to nurturing ourlocal communities through corporate social responsibility and co-prosperity initiatives. Samsung has also remainedsteadfast when it comes to supporting education initiatives, helping to preserve the "greening" of the planet whereyou live.

"A global leader is not only responsible for that which lies within its walls but alsofor that which lies beyond them."

Reported by GreenpeaceSamsung comes in second place with 5.7, scoring well on

chemicals and waste criteria. Samsung's score on e-waste is

helped by getting top marks for reporting recycling rates of

137% for TVs (based on past sales 10 years ago, the average

life span, since when Samsung's TV sales have increased

10-fold), 12% for PCs (based on 7 year lifespan) and 9%

for mobile phones (based on 2 year lifespan). It also scores well

on its use of recycled plastic, which is 16.1%, though only 0.2%

is post-consumer plastic, with a goal to increase to 25% by 2008.

Nokia:Clear leader after improving take-back inIndia.

SAMSUNG / Good scores on chemicalsand e-waste criteria.

Fujitsu Siemens:New deadline for removal ofBFRs and PVC but still poor on recycling.

Sony Ericsson:Good on toxic chemicals andenergy but very poor on recycling.

Sony:Good on toxic chemicals, room forimprovement on energy.

LG:Improved score on recycling and energy.

Toshiba:Improved climate policy, but poor on recycling.

Dell:Dropping down with poor scores on climate policy.

HP:Slightly improved score but no productsfree of most toxic chemicals.

Acer:Good on chemicals policy but poor onenergy policy.

Panasonic:Needs to improve recycling andamount of renewable energy.

Philips:Worst company on recycling with additional penalty for negative lobbying in Europe.

Apple:Progress on eliminating toxics from newproducts but needs to improve on recycling andenergy.

Lenovo:New US tack back scheme, but still noproducts free of worst toxic chemicals.

Motorola:Only phone company not to set atimeline for eliminating worst toxic chemicals.

Sharp:Most points on toxic chemicals, poor onrecycling and energy.

Microsoft:Very poor on recycling and energy.

Nintendo:Zero on most criteria except chemicalsmanagement and energy.

[Standard for the second quarter, 2008]

7

5.7

5.5

5.3

5.3

4.9

4.7

4.7

4.7

4.5

4.5

4.3

4.1

4.1

3.7

3.1

2.2

0.8

Eco-labels & DeclarationSamsung Electronics makes an effort to develop environment-

friendly products that minimize the negative impacts on the

environment in every aspect of its products, from raw material

procurement, production, transportation, usage, and final

disposal. Concerns for the environment are at the core of each

product development.

Samsung's environment-friendly technologies and recycling

programs have received global approval, receiving well-known

awards and recognitions worldwide.

Samsung eco mark Energy mark Korea Eco Mark Korea

Ecoflower EU Energy Star Mark TCO Sweden

Blue Angel Germany EPEAT US Eco Mark Korea 2

Page 5: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Type 9K Btu/h

2.6 kW

12K Btu/h

3.5 kW

18K Btu/h

5.2 kW

21K Btu/h

6.0 kW

24K Btu/h

7.0 kW

30K Btu/h

9.0 kW

36K Btu/h

10.5 kW

48K Btu/h

14.0 kW

Non-inverter

S-Inverter

R-Inverter

1Phase

1Phase

3Phase

1Phase

3Phase

Technology

CapacityR410A

2009 Product Line-up This year’s product line-up still supports a wide range ofchoices, all of them equipped with Samsung’s advancedtechnology.

OUTDOOR UNITS

08092009 Samsung Ceiling Air Conditioners'Eco-friendly'- Samsung

Preserves the nature you live in.Thinking of you and the environment, Samsung plans for the future. Realizing your hopes for a greener, healthierlife for you and the generations that follow, Samsung's environmentally friendly technologies work to make theworld a more beautiful place.

Air & Water ConservationAs a leading innovator of environment-friendly products and technologies, Samsung products already drastically reduce the strains on nature's valuable resources. Samsung uses R-600, a natural refrigerant, and cyclopentane insulation in its refrigerators, which do not promote global warming and does not add to the greenhouse effect. Samsung's water-efficient washing machines also use less detergent and water withoutaffecting cleanliness, helping to conserve water.

Use Less, Save MoreSamsung products are energy efficient, receiving Energy Grade A+ in the EU and ENERGY STAR in the U.S.Samsung washers with its ceramic heaters use less power, which saves you energy, money, and time. Thisenergy-efficient technology protects you and nature, giving you a greener lifestyle.

Global RecyclingSamsung Electronics is making significant efforts to save the environment and complies with the WEEE(Waste Electrical and Electronic Equipment) directive by joining or establishing the recycling schemes for eachcountry.

Samsung Eco-Friendly System Air ConditionerMaking continuous efforts to stay eco-friendly, Samsung's air

condition-ers use R-410A, an environmentally friendly refrigerant to

help rid the air of pollutants and restrain the use of materials with high

global warming potential (GWP). Most Samsung products have

received Energy Grade A+ in the EU and ENERGY STAR in the U.S.

These energy-efficient air conditioners not only save you money, but

help conserve the environment.

Page 6: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

2009 Product Line-up

INDOOR UNITS

This year’s product line-up still supports a wide rangeof choices, all of them equipped with Samsung’sadvanced technology.

R410A

9K Btu/h

2.6 kW

12K Btu/h

3.5 kW

18K Btu/h

5.2 kW

24K Btu/h

7.0 kW

30K Btu/h

9.0 kW

36K Btu/h

10.5 kW

48K Btu/h

14.0 kW

21K Btu/h

6.0 kWTechnologyType Capacity

10112009 Samsung Ceiling Air Conditioners

1Way cassette

4Way cassette

Ceiling

Slim Duct

MSP Duct

Mini 4Way cassette

Console

2Way cassette

Inverter

Inverter

R-Inverter

Inverter

Inverter

Inverter

Inverter

Inverter

R - Inverter

Non-inverter

Non-inverter

Non-inverter

Non-inverter

Non-inverter

Page 7: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

12132009 Samsung Ceiling Air Conditioners

25 C

24 C

23 C

25 26 27 28 29 30 31 10 12 14 16 18 20 22 24 26

27'21"

31'24"

17'41"

27'23"

Faster Faster

Fast Cooling and HeatingWhen you change the temperature setting, the airconditioner will use the compressor's maximumcapacity to quickly reach the desired temperature,resulting in 15% faster cooling and 50% faster heating.

Comfortable TemperatureThe S-Inverter Air Conditioner works at maximumcapacity at start up. As soon as the temperaturereaches the desired set temperature, it finely adjuststo cope with any changes. This means less temperaturefluctuation and assures you greater comfort that canbe achieved in minutes.

High EfficiencyThe S-Inverter technology gives you powerful, speedycooling and heating at minimum electricity consumption,so you can reduce energy waste and save money.

Up to 50% Energy SavingAfter reaching the set temperature, the S-Inverter AirConditioner changes its operation mode to economic.By avoiding inefficient and frequent switching on andoff of the compressor, the S-Inverter saves up to 50%in energy consumption compared with a non-inverterair conditioner.

200 300 400 500 600

302Wh/h

621.4Wh/h

Saving

Silent OperationEnjoy peace and quiet. The air conditioner's compressor operates at the lowest speed possible tomaintain the desired temperature, so there's lessmotor and fan noise.

20dB 25 30

27dB Silent

Wide Temperature PerformanceNo need to worry about using an external unit insevere temperatures with a Samsung air conditioner.With a wider temperature allowance, the unit can coolin the burning heat of 50°C or heat in the freezingcoldness of -20°C to provide comfort in your home. -10 0 10

Wider operation Range

20 30 40 -20 -10 0 10 20 30

-10oC ~ 15oC

-20oC ~ 24oC

Wider operation Range

Comfortable

S-InverterSteady Temperature Fluctuation

Non InverterHigh Temperature Fluctuation

Uncomfortable(Energy Loss)

Uncomfortable(Energy Loss)In reducing electricity costs for an air conditioner, an inverter is a must. Samsung’s S-Inverter

technology lowers energy consumption by up to 50% compared to a conventional air conditioner.

Its powerful and delicate control lets you reach the desired temperature quickly and maintains

precise temperatures so there’s less fluctuation and less motor run-time, which means quieter

operating noise and less energy waste.

Strong and Quiet S-Inverter

Page 8: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

INDOOR UNITS01

14152009 Samsung Ceiling Air Conditioners

Cold air, delivered evenly toevery corner of your spaceIndoor units made just for you! Samsung’s indoor units have their own individual

unique features for the perfect air throughout the entire space. Indoor units

designed to fit all the different types of space. It will make you feel like owning

your own customized air conditioner just for you.

18

22

28

30

| Slim 1Way Cassette

| 4Way Cassette

| Mini 4Way Cassette

| 2Way Cassette

| Cassette Type

34

36

| Slim Duct

| MSP Duct

| Duct Type

44

48

| Console

| Ceiling

| Floor & Convertible Type

Page 9: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Wide BladeThe new cassette type air conditioner is equipped with uniquely designed blades that are wider to provide evencooling and heating power throughout the room.

WIDEWIDEWIDEWIDE

64mm

46mm

WIDER

Airflow is directed towards theceiling which cause ceilingsoiling.

Airflow is directed downwardswithout having contact with theceiling.

Ceiling Soiling PreventionNewly designed panel will control the air direction to avoidhaving contact with the ceiling. This new design will preventthe ceiling soiling and keep your interior cleaner than evereven, after long period of operation.

Conventional Blade

Ceiling Ceiling

New Blade

600(mm) 650

Lift-up Range

700 750

750mm

700mm

High Lift-up Drain PumpThe lift-up drain pump lifts condensed water up to 750mm,compared to the competitor’s 700mm, allowing for flexibleand convenient installation.

Fresh Air IntakeWith optional installation of an air intake motor, fresh aircan enter through the cassette unit so you have fresherair in the room.

Sub DuctThe Sub Duct lets you use the same air conditioner unit tocool another smaller space nearby. (The cassette unit is fitted with a knock-out component to accommodate this.)

Quick Connection of Drain PipeSamsung's unique drain pipe prevents leaks and is easierto install with no need to use tape or adhesives.

FRESHFRESHFRESHFRESH

SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK

HIGHHIGHHIGHHIGH

Company A

Fresh air

Motor

Samsung

Cassette type Air conditionersSamsung’s Ceiling type air conditioner offers four different types of models with stylish designtogether with functionality. Indoor units that blends in and adds elegancy to any type of spaceis the origin of the cool air that fills the entire space.

16172009 Samsung Ceiling Air Conditioners

Page 10: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Slim 1Way CassetteSuper slim design helps easier installation and the quiet operation still provides the strongest air.

Slim and Compact Design

Slim 1Way CassetteWant a cassette type air conditioner, but have limited space? Samsung's new Slim 1Way cassette type air conditioner is the answer.

10.5kg

17kg

38% Down

4kW R410A model Weight

Only 135mm thickSamsung introduces the world's slimmest indoorair conditioner unit. Only 135mm thick, the slim 1Way Cassette air conditioner can be installedpractically anywhere.

Lighter indoor unitThe first to apply ABS cabinets into its indoorunits, Samsung has achieved the lightest unitson the market. Its slim lightweight design makesinstallation and maintenance a breeze.

Ensure that there is sufficient installation space. Allow at least170mm for the installation.

NOTE

Min. 170mm

Quiet OperationSamsung's new blade design drastically reduces noise levels, so you can relax in peace and quiet.

25dB

35dB

30dB

43dB

Low

High

Fan speed Noise level

Check Valve Inside Drain PumpFaulty drainage installation or power failures can cause condensed water to flow back into the unit,causing leakage and odors. Samsung's air conditioners are equipped with a check valve built directlyinto the drain pump to prevent water from flowing backward.

Check ValveOptional Accessories

PSSMAMR-CH01MWR-TH01 MWR-SH00

Individual Controllers

Panel

WIDE BLADEQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK

18192009 Samsung Ceiling Air Conditioners

MWR-WS00MWR-WE00

135m

m

155m

m

Drain pan is included within panel

Page 11: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Slim 1Way Cassette

Specification | Slim 1Way Cassette

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

SH026EAV1UH026EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

980/2,600/3,500950/3,300/4,600245/695/1,120210/910/1,300

3.74(A)3.63(A)

1.6/3.3/5.21.4/5.3/6.46.35(1/4)9.52(3/8)

1/220-240/50

SH026EAV1PSSMA

CROSS FLOW FAN8

970X135X4101,164X212X478

10.0/13.61,180X25X4601,250X126X530

3.1/4.530/25

DEFAULT

UH026EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950201550

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

SH035EAV1UH035EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

980/3,500/4,100950/4,000/4,750250/1,140/1,420210/1,160/1,390

3.07(A)3.45(A)

1.6/5.3/6.61.4/5.5/6.86.35(1/4)9.52(3/8)

1/220-240/50

SH035EAV1PSSMA

CROSS FLOW FAN8.5

970X135X4101,164X212X478

10.0/13.61,180X25X4601,250X126X530

3.1/4.532/27

DEFAULT

UH035EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950201550

20212009 Samsung Ceiling Air Conditioners

Indoor Unit

Outdoor Unit

Indoor Unit

Outdoor Unit

Page 12: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

4Way CassetteWith the air coming out from four different places, the 4Way Cassette type indoor units provide conditioned air to everycorner of the space.

Optional Accessories

Panel

New Turbo Fan

Quiet OperationImagine a room of cool calmness. Theaerodynamically designed ‘Turbo Fan'minimizes noise from the turbulenceof blade movement. Therefore noiseis less than conventional models.

Uniform DistributionThe new 'Turbo Fan' with wide bladesprovides extreme cooling and heatingpower from 4 separate outlets so theentire room gets cool or warm faster.Now, every nook and cranny is comfortable.

Easy LevelingEach corner portion of the panel is detachable,which gives easier access to adjust the height,therefore leveling and installation is much easierand quicker than before.

Compact SizeThe 4Way cassette type unit has gotten even slimmer.Now only 218mm thick (5.2/7.0/9.0kW), 24% slimmercompare to competitor’s 288mm (9.0kW). It's stillthe industry leader in compactness and is eveneasier to install in tight spaces.

Efficient Cooling3-dimensional shaped blade, which has the world wide patent, is able to spread cool or warm air further andevenly to all corners of the space.

Conventional 4Way

Conventional 4Way

New 4Way

New 4Way

Detachable corners make installationand height adjustments much easier.

Air distribution

Detaching the whole panel tookmore time.

218mm

Air distribution

Outlet1

Outlet2

Outlet3

Outlet4

‘A’ View

‘B’ View

‘C’ View

WIDE BLADEFRESH AIR INTAKE

SUB DUCTQUICK CONNECTION OF DRAIN PIPE

CEILING SOILINGPREVENTION

HIGH LIFT-UP DRAIN PUMPWIDEWIDEWIDEWIDE HIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH SUB DUCTSUB DUCTSUB DUCTSUB DUCT QUICKQUICKQUICKQUICK

P4SMA

Stylish Panel DesignThe stylish panel is well harmonized with any interior design.

22232009 Samsung Ceiling Air Conditioners

MR-CH01MWR-TH01 MWR-SH00

Individual Controllers

MWR-WS00MWR-WE00

Page 13: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

24252009 Samsung Ceiling Air Conditioners

4Way Cassette

Specification | 4Way Cassette

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

CH070EAV1UH070EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

2,100/7,100/8,4002,000/8,000/11,600

510/2,120/2,700500/2,190/3,750

3.35(A)3.65(A)

2.8/9.3/12.12.6/9.6/16.9

6.35(1/4)15.88(5/8)

1/220-240/50

CH070EAV1P4SMA

TURBO FAN17.2

840X218X840926X280X925

31/35950X35X950

1,042X103X1,0427.0/10.336/30

DEFAULT

UH070EAV1TWIN BLDC

R410A880X798X310

1,038X861X41357/61

52-15~43-20~241,900

5030530

CH090EAVUH090EAV

3,200/9,000/10,0003,000/10,000/13,900

750/2,800/3,200580/2,770/4,660

3.21(A)3.61(A)

3.5/12.5/14.12.8/12.2/20.6

9.52(3/8)15.88(5/8)

1/220-240/50

CH090EAVP4SMA

TURBO FAN24

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.339/32

DEFAULT

UH090EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X47295/110

56-15~50-20~242,600

75307.540

CH105EAVUH105EAV

3,200/10,500/12,0002,600/11,200/15,500

700/3,270/3,800580/3,100/5,600

3.21(A)3.61(A)

3.3/14.5/16.83.6/13.7/24.3

9.52(3/8)15.88(5/8)

1/220-240/50

CH105EAVP4SMA

TURBO FAN25.7

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.340/33

DEFAULT

UH105EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X47295/110

56-15~50-20~242,800

75307.540

CH105EAVUH105GAV

3,200/10,500/12,0002,600/11,200/15,500

700/3,270/3,800580/3,100/5,600

3.21(A)3.61(A)

1.3/5.0/6.01.1/5.0/8.69.52(3/8)

15.88(5/8)3/380-415/50

CH105EAVP4SMA

TURBO FAN22.2/25.7

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.340/33

DEFAULT

UH105GAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X47288/93

56-15~50-20~242,800

75307.540

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

CH140EAVUH140EAV

3,800/14,000/15,4003,450/16,000/18,500

900/4,650/5,400750/4,690/5,800

3.01(B)3.41(B)

4/20.6/23.53.6/20.8/26.5

9.52(3/8)19.05(3/4)

1/220-240/50

CH140EAVP4SMA

TURBO FAN30

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.345/38

DEFAULT

UH140EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472105/120

59-15~50-20~243,100

75307.540

CH140EAVUH140GAV

3,800/14,000/15,4003,450/16,000/18,500

900/4,650/5,400750/4,690/5,800

3.01(B)3.41(B)

4/20.6/23.53.6/20.8/26.5

9.52(3/8)19.05(3/4)

3/380-415/50

CH140EAVP4SMA

TURBO FAN28/30

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.345/38

DEFAULT

UH140GAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472105/120

59-15~50-20~242,800

75307.540

CH090EASUH090EAS

3,100/9,000/10,0002,750/9,500/13,000

680/2,800/3,400530/2,630/4,550

3.21(A)3.61(A)

3.2/12.4/15.02.54/11.65/20.0

9.52(3/8)15.88(5/8)

1/220-240/50

CH090EASP4SMA

TURBO FAN24

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.339/32

DEFAULT

UH090EASTWIN BLDC

R410A880x950x320

1043x1062x41178/85

52-15~50-20~242,400

7530555

R-Inverter

Indoor Unit

Outdoor Unit

Indoor Unit

Outdoor Unit

Page 14: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

4Way Cassette

Specification | 4Way Cassette

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling/Heating

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

CH052EAMCUH052EAMCModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

5,4006,0001,9001,950

2.84(C) 3.08(D)

8.58.6

6.35(1/4)12.7(1/2)

1/220-240/50

CH052EAMCP4SMA

TURBO FAN14

840X218X840925X280X925

25/31950X35X950

1,042X103X1,0427.0/10.334/29

DEFAULT

UH052EAMCROTARYR410A

880X648X3101,023X744X413

59/6649

-5~43-5~241,500

30157.525

CH070EAM1CUH070EAM1C

7,0007,2002,4002,350

2.92(C) 3.06(D)

11.0 11.0

6.35(1/4)15.88(5/8)

1/220-240/50

CH070EAM1CP4SMA

TURBO FAN18.5

840X218X840925X280X925

25/31950X35X950

1,042X103X1,0427.0/10.336/30

DEFAULT

UH070EAM1CROTARYR410A

880X648X3101,023X744X413

60/6751

-5~43-5~241,700

30157.540

CH094EAMCUH094EAM1C

9,0009,5003,4003,500

2.65(D) 2.71(E) 15.516.0

6.35(1/4)15.88(5/8)

1/220-240/50

CH094EAMCP4SMA

TURBO FAN21.5

840X218X840925X280X925

25/31950X35X950

1,042X103X1,0427.0/10.339/32

DEFAULT

UH094EAM1CROTARYR410A

880X798X3101,023X891X413

74/8255

-5~43-5~241,800

30157.550

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

CH105EAMCUH105EAMC

10,00010,7003,8303,850

2.61(D) 2.78(E) 17.517.5

9.52(3/8)19.05(3/4)

1/220-240/50

CH105EAMCP4SMA

TURBO FAN24.5

840X298X840925X360X925

28/34950X35X950

1,042X103X1,0427.0/10.340/33

DEFAULT

UH105EAMCSCROLLR410A

880X931X3201,043X411X1,062

87/9256

-5~43-5~242,600

50307.570

CH105EAMCUH105GAMC

10,00010,7003,5603,600

2.81(C) 2.97(D)

6.26.3

9.52(3/8)19.05(3/4)

3/380-415/50

CH105EAMCP4SMA

TURBO FAN24.5

840X298X840925X360X925

28/34950X35X950

1,042X103X1,0427.0/10.340/33

DEFAULT

UH105GAMCSCROLLR410A

880X931X3201,043X411X1,062

87/9256

-5~43-5~242,750

50307.570

CH140EAMCUH140GAMC

14,00015,4005,3005,9002.64 2.61 9.210.0

9.52(3/8)19.05(3/4)

3/380-415/50

CH140EAMCP4SMA

TURBO FAN29

840X298X840925X360X925

29/35950X35X950

1,042X103X1,0427.0/10.345/38

DEFAULT

UH140GAMCSCROLLR410A

932X1,128X3751,091X1,286X472

121/13659

-5~43-5~243,300

50307.570

26272009 Samsung Ceiling Air Conditioners

Indoor Unit

Outdoor Unit

Indoor Unit

Outdoor Unit

Page 15: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Mini 4Way CassetteFour way airflow for large coverage with more compact size, it is best for the place with smaller ceiling structure.

FRESH AIR INTAKE

QUICK CONNECTION OF DRAIN PIPE

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH FRESHFRESHFRESHFRESH QUICKQUICKQUICKQUICK

High Energy EfficiencyNot only is the Mini 4Way cassette air conditioner small and compact, it's energy efficient. Easy operation coupled withhigh efficiency provides you with remarkable performance at extremely low cost.

Fan Speed AdjustmentFan speed can be adjusted by ceiling height. With an easy touse PCB option, air flow can be altered for use in high ceilings.

Ideal Compact SizeThe Mini 4Way cassette air conditioner can be installed in one standard ceilingtile (600Wx600H) so construction or alterations to the ceiling are unnecessary.

3~3.5m 2.7m

High Ceiling

On : Increased fan speed Off : Standard fan speed

Unit : mm

Standard Ceiling

PMSMA

28292009 Samsung Ceiling Air Conditioners

Optional Accessories

Panel

Specification | Mini 4Way Cassette

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

TH026EAV1UH026EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

990/2,600/3,500980/3,300/4,600260/730/1,100240/900/1,400

3.56(A)3.67(A)

1.6/3.4/5.11.5/4.3/6.66.35(1/4)9.52(3/8)

1/220-240/50

TH026EAV1PMSMA

TURBO FAN11.0

575X260X575660X310X635

17/20670X35X670717X93X717

2.6/4.230/25

DEFAULT

UH026EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950 201550

TH035EAV1UH035EAV1

990/3,500/4,200980/4,000/5,000260/1,090/1,400250/1,100/1,400

3.21(A)3.64(A)

1.6/5.0/6.41.5/5.1/6.76.35(1/4)9.52(3/8)

1/220-240/50

TH035EAV1PMSMA

TURBO FAN12.0

575X260X575660X310X635

17/20670X35X670717X93X717

2.6/4.234/27

DEFAULT

UH035EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950 201550

TH052EAV1UH052EAV1

1,050/4,700/6,3001,300/5,500/8,600420/1,460/2,150350/1,590/2,950

3.22(A)3.46(B)

2.4/7.0/10.02.6/8.0/15.0

6.35(1/4)12.7(1/2)

1/220-240/50

TH052EAV1PMSMA

TURBO FAN12.9

575X260X575660X310X635

17/20670X35X670717X93X717

2.6/4.241/33

DEFAULT

UH052EAV1TWIN BLDC

R410A880X638X310

1,023X704X41350/53

49-15~43-20~241,450

5030530

TH060EAV1UH060EAV1

1,800/5,800/6,5001,800/7,000/10,000

520/1,930/2,050470/2,180/3,600

3.01(B)3.21(C)

2.6/8.8/9.42.4/10.0/16.0

6.35(1/4)15.88(5/8)

1/220-240/50

TH060EAV1PMSMA

TURBO FAN13.6

575X260X575660X310X635

17/20670X35X670717X93X717

2.6/4.241/33

DEFAULT

UH060EAV1TWIN BLDC

R410A880X798X310

1,038X861X41357/61

52-15~43-20~241,900

5030530

MR-CH01MWR-TH01 MWR-SH00

Individual Controllers

MWR-WS00MWR-WE00

Indoor Unit

Outdoor Unit

Page 16: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

2Way CassetteAir coming out from two sides together with its size can be a perfect fit for long and narrow places withlimited installation space.

QUICK CONNECTION OF DRAIN PIPE

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH QUICKQUICKQUICKQUICK

Small Size Big PerformanceThe 2Way cassette air conditioner is now 45% smaller thancompetitor’s models, so it's even easier to incorporate intobuilding design.

Twin Cross Flow FanThe 2Way cassette type unit is perfect fit for long and narrowrectangular type of space. Twin Cross Flow Fan inside of the2Way cassette will spread cool or warm air even further andwider with less noise.

Standard Formula for Easy InstallationThe dimensions of the 2Way cassette air conditioner allows for easyinstallation into standard ceiling grids (600Wx600H), so everythingjust falls into place.

230mm

890mm575mm

45%Decreased

305mm

1,180mm600mm

600mm

600mm

Cross flow fans

P2SMA

30312009 Samsung Ceiling Air Conditioners

Optional Accessories

Panel

Specification | 2Way Cassette

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

GH052EAMGUH052EAMCModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

5,5006,0001,7001,8003.24(A) 3.33(C)

7.57.9

6.35(1/4)12.7(1/2)

1/220-240/50

GH052EAMGP2SMA

CROSS FLOW FAN14

890X230X5751,107X299X642

21/251,180X20X4601,259X144X539

3.5/6.236/28

DEFAULT

UH052EAMCROTARYR410A

880x648x3101,023X744X413

59/6649

-5~43-5~241,500

30157.525

GH070EAMGUH070EAM1C

7,0007,7002,3502,500

2.98(C)3.08(D)

10.511

6.35(1/4)15.88(5/8)

1/220-240/50

GH070EAMGP2SMA

CROSS FLOW FAN14

890X230X5751,107X299X642

22/261,180X20X4601,259X144X539

3.5/6.238/28

DEFAULT

UH070EAM1CROTARYR410A

880x648x3101,023X744X413

60/6751

-5~43-5~241,700

30157.540

Individual Controllers

Indoor Unit

Outdoor Unit

MR-CH01MWR-TH01 MWR-SH00MWR-WS00MWR-WE00

Page 17: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Duct type Air conditionersWith the widest range of products, Samsung’s duct type air conditioners are perfect for any space withits slim size that offers flexible installation option. The smart pressure control system gives silent operation so that the air conditioning never becomes a distraction.

Clean Filter SystemThe anti-bacteria filter and the filter cleaning indicator provide you with cleaner, healthier air. You deserve to breathe fresh air everyday.

Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles,but suppresses proliferation of molds and bacteria.

BACTERIABACTERIABACTERIABACTERIA Easy Filter CleaningAfter 1,000 hours of operation the filter cleanindicator will inform you that the filter should becleaned. The filter can be easily removed fromthe bottom, left, or right of the unit. (1,000 hoursis the default set time, which can be adjusted to2,000 hours on the internal PCB.)

High Lift-up Drain Pump (optional)The lift-up drain pump lifts condensed water up to 750mm, compared to the competitor’s 700mm, allowing for flexible and convenient installation.

HIGHHIGHHIGHHIGH

Smart Pressure ControlThe Smart Pressure Control System adjusts fan speed according toE.S.P(External Static Pressure), so the air conditioner always givesyou consistent cooling and heating power regardless of the surrounding environment.

E.S.P Control

Air v

olum

e

Static pressure (mmAq)Minimum Maximum

H

H

M

M

L

L

WiredWiredWiredWired Wired Remote ControllerWired remote controller is included for more convenient use of the air conditioner.

32332009 Samsung Ceiling Air Conditioners

Page 18: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Slim DesignOnly 199mm thick, this slim design makes installation, maintenance,and repair easy.

Easy to MaintainParts are easily accessible bysimply opening the bottompanel, which reduces timeand maintenance costs.

199mm

199mm

220mm

225mm

160 180 200 220210 230

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

EASY FILTER CLEANING

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH

SMART PRESSURECONTROL

Flexible InstallationThe air inlet can be set up on either the bottomor rear of the unit, so there is more flexibility ininstallation.

Rear side air inlet Bottom side air inlet

Suction Duct Suction Duct

TexTex

Diffuser Diffuser

Slim DuctSlim duct type indoor units with industry leading compact size gives flexible installation and easier maintenance options.

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

EH035EAV1UH035EAV1980/3,500/4,200980/4,000/5,200260/1,150/1,400210/1,105/1,700

3.04(B)3.62(A)

1.7/5.3/6.41.3/5.1/7.96.35(1/4)9.52(3/8)

1/220-240/50

EH035EAV1-

SIROCCO FAN11.00/2/4

990X199X6001,133X333X722

26/31---

32/27MDP-E075SEE

DEFAULT

UH035EAV1SINGLE BLDC

R410A790X548X285938X610X382

35.5/3847

-10~43-15~24

950 201550

EH052EAV1UH052EAV1

1,700/5,000/6,0001,500/6,000/8,000420/1,550/1,950360/1,650/2,700

3.23(A)3.64(A)

2.5/7.0/8.52.1/7.5/12.0

6.35(1/4)12.7(1/2)

1/220-240/50

EH052EAV1-

SIROCCO FAN16.50/2/4

1,100X199X6001,330X330X730

31/39---

33/30MDP-E075SEE

DEFAULT

UH052EAV1TWIN BLDC

R410A880X638X310

1,023X704X41350/53

49-15~43-20~241,450

5030530

EH070EAV1UH070EAV1

2,200/7,100/8,0002,000/8,000/12,000

570/2,200/2,650500/2,150/3,800

3.23(A)3.72(A)

2.9/10.0/12.02.8/10.0/16.5

6.35(1/4)15.88(5/8)

1/220-240/50

EH070EAV1-

SIROCCO FAN19.60/2/4

1,100X199X6001,330X330X730

31/39---

36/32MDP-E075SEE

DEFAULT

UH070EAV1TWIN BLDC

R410A880X798X310

1,038X861X41357/61

52-15~43-20~241,900

5030530

EH052EAMCUH052EAMC

5,5006,3001,9502,0002.82 3.15 9.00 9.00

6.35(1/4)12.7(1/2)

1/220-240/50

EH052EAMC-

SIROCCO FAN14.90/2/4

900X199X6001,124X315X713

26/30---

33/30MDP-E075SEE

DEFAULT

UH052EAMCROTARYR410A

880X648X3101,023X704X413

59/6649

-5~43-5~241,500

30157.540

EH070EAM1CUH070EAM1C

6,8007,5002,4202,4202.81 3.10 11.10 11.10

6.35(1/4)15.88(5/8)

1/220-240/50

EH070EAM1C-

SIROCCO FAN20.50/2/4

1,100X199X6001,330X330X730

30.5/38.5---

36/32MDP-E075SEE

DEFAULT

UH070EAM1CROTARYR410A

880X648X3101,023X704X413

60/6751

-5~43-5~241,700

30157.540

WIRED REMOTE CONTROLLERWiredWiredWiredWired

Drain Pump

MDP-E075SEE / MDP-E075SEE1

Indoor Unit

Outdoor Unit

34352009 Samsung Ceiling Air Conditioners

Optional Accessories

Specification | Slim Duct

Individual Controllers

MR-CH01MWR-TH01MWR-WS00MWR-WE00

Page 19: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

EASY FILTER CLEANING

HIGH LIFT-UP DRAIN PUMPHIGHHIGHHIGHHIGH

SMART PRESSURECONTROL

MSP DuctFlexible installation options offer a variety of solutions for different shapes of room, and the smart pressure controlsystem provides quiet operation.

WIRED REMOTE CONTROLLERWiredWiredWiredWired

Flexible InstallationSamsung's MSP Duct air conditioners offer different solutionsfor any shape room allowing for specific airflow requirements.

L-shaped area Y-shaped areaAreas far apart

Silent Operation with the static pressure controlThe external static pressure control makes it easy to design duct work to ensure efficiency and silent operation.

Narrow Width (5.2kW) Middle Static Pressure

900mm Slim DuctmmAq

2

4

6

8

10

MSP Duct

0~10mmAq

0~6mmAq

Width measured without control box.

Easy to MaintainReduce time and maintenance costsby keeping parts easily accessible.

R-Inverter

36372009 Samsung Ceiling Air Conditioners

Drain Pump

MDP-M075SGU1 / MDP-M075SGU2 / MDP-M075SGU3

Optional Accessories

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

DH052EASUH052EAS

1,600/5,000/6,0001,500/6,000/9,000540/1,550/1,950500/1,750/3,000

3.23(A)3.43(B)

2.7/7.1/8.72.5/8.0/13.5

6.35(1/4)12.70(1/2)

1/220-240/50

DH052EAS-

SIROCCO FAN16.50/4/6

900X260X4801,146X363X584

29.5/34.5---

37/33MDP-M075SGU3

DEFAULT

UH052EASTWIN BLDC

R410A880X638X310

1,023X704X41350/53

49-10~43-15~241,350

3020520

DH070EASUH070EAS

2,200/7,100/8,0001,900/8,000/10,500

700/2,720/3,070620/2,490/3,670

2.61(D)3.21(C)

3.1/12.4/13.72.71/11.4/16.3

6.35(1/4)15.88(5/8)

1/220-240/50

DH070EAS-

SIROCCO FAN21

0/4/6900X260X480

1,146X363X58429.5/34.5

---

38/34MDP-M075SGU3

DEFAULT

UH070EASTWIN BLDC

R410A880X638X310

1,023X704X41350/53

52-10~43-15~241,350

3020530

DH090EASUH090EAS

3,100/9,000/10,0002,900/9,500,/13,000

850/3,200/3,600680/2,960/4,650

2.81(C)3.21(C)

3.82/14.0/15.83.1/13.0/20.5

9.52(3/8)15.88(5/8)

1/220-240/50

DH090EAS-

SIROCCO FAN24

0/6/81,150X260X4801,390x345x575

33/40---

39/35MDP-M075SGU1

DEFAULT

UH090EASTWIN BLDC

R410A880x950x320

1,043x1,062x41178/85

52-15~50-20~242,400

7530555

DH105EASUH105EAS

3,000/10,500/12,0003,300/11,200/13,700

840/3,730/4,400760/3,720/5,000

2.81(C)3.01(D)

3.6/16.5/18.53.2/16.5/29.0

9.52(3/8)15.88(5/8)

1/220-240/50

DH105EAS-

SIROCCO FAN24

0/6/81,150X260X4801,390X345X575

34/40---

40/33MDP-M075SGU1

DEFAULT

UH105EASTWIN BLDC

R410A932X1,128X375

1,091X1,286X472102/117

56-15~50-20~242,600

75307.540

Indoor Unit

Outdoor Unit

Specification | MSP Duct

MR-CH01MWR-TH01

Individual Controllers

MWR-WS00MWR-WE00

Page 20: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

MSP Duct

Specification | MSP Duct

38392009 Samsung Ceiling Air Conditioners

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

DH105EAVUH105EAV

3,350/10,500/12,0002,600/11,200/15,500

830/3,270/3,700740/3,100/5,500

3.21(A)3.61(A)

3.8/14.7/16.84.5/14.1/25.0

9.52(3/8)15.88(5/8)

1/220-240/50

DH105EAV-

SIROCCO FAN28.1

0/8/101,150X320X4801,396X424X584

39/46---

39/35MDP-M075SGU1

DEFAULT

UH105EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472102/117

56-15~50-20~242,800

75307.540

DH105EAVUH105GAV

3,350/10,500/12,0002,600/11,200/15,500

830/3,270/3,700740/3,100/5,500

3.21(A)3.61(A)

1.4/5.0/6.11.3/5.0/8.59.52(3/8)15.88(5/8)

3/380-415/50

DH105EAV-

SIROCCO FAN27.5/28.1

0/8/121,150X320X4801,396X424X584

39/46---

39/35MDP-M075SGU1

DEFAULT

UH105GAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472102/117

56-15~50-20~242,800

75307.540

DH140EAVUH140EAV

3,450/14,000/15,4003,750/16,000/18,5001,110/4,650/5,7001,020/4,430/5,800

3.01(B)3.61(A)

5.0/20.6/23.54.5/19.6/26.5

9.52(3/8)19.05(3/4)

1/220-240/50

DH140EAV-

SIROCCO FAN36.8

0/8/101,200X360X6501,447X425X769

55/60---

43/38MDP-M075SGU2

DEFAULT

UH140EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472105/120

59-15~50-20~243,100

75307.540

DH140EAVUH140GAV

3,450/14,000/15,4003,750/16,000/18,5001,110/4,650/5,7001,020/4,430/5,800

3.01(B)3.61(A)

1.8/7.4/8.81.7/7.0/9.59.52(3/8)19.05(3/4)

3/380-415/50

DH140EAV-

SIROCCO FAN35.6/36.8

0/8/121,200X360X6501,447X425X769

55/60---

43/38MDP-M075SGU2

DEFAULT

UH140GAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472105/120

59-15~50-20~242,800

75307.540

Indoor Unit

Outdoor Unit

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

DH090EAVUH090EAV

3,000/9,000/10,0003,300/9,500/13,500

840/2,800/3,400760/2,780/4,790

3.21(A)3.41(B)

3.5/12.4/15.03.1/12.3/24.5

9.52(3/8)15.88(5/8)

1/220-240/50

DH090EAV-

SIROCCO FAN24

0/6/81,150X260X4801,390X345X575

33/40---

39/35MDP-M075SGU1

DEFAULT

UH090EAVTWIN BLDC

R410A932X1,128X375

1,091X1,286X472102/117

56-15~50-20~242,600

75307.540

DH070EAV1UH070EAV1

2,200/7,100/8,0001,900/8,000/11,000

600/2,210/2,600470/2,210/3,700

3.21(A)3.62(A)

2.9/10.0/12.02.8/10.0/16.5

6.35(1/4)15.88(5/8)

1/220-240/50

DH070EAV1-

SIROCCO FAN19.60/4/8

1,150X260X4801,390X345X575

34/40---

39/35MDP-M075SGU1

DEFAULT

UH070EAV1TWIN BLDC

R410A880X798X310

1,038X861X40657/61

52-15~43-20~241,900

5030530

DH052EAV1UH052EAV1

1,700/5,000/60,001,700/6,000/8,300550/1,560/1,950480/1,760/2,750

3.21(A)3.41(B)

3.1/7.5/9.32.6/8.4/13.1

6.35(1/4)12.7(1/2)

1/220-240/50

DH052EAV1-

SIROCCO FAN16.50/4/6

900X260X4801,146X363X584

29.5/34.5---

37/33MDP-M075SGU3

DEFAULT

UH052EAV1TWIN BLDC

R410A880X638X310

1,023X704X41350/53

49-15~43-20~241,450

5030530

Indoor Unit

Outdoor Unit

Page 21: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

MSP Duct 40412009 Samsung Ceiling Air Conditioners

Specification | MSP Duct

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

DH094EAMCUH094EAM1C

8,800 9,5003,6503,5002.41(E) 2.71(E)16.515.5

9.52(3/8)15.88(5/8)

1/220-240/50

DH094EAMC-

SIROCCO FAN24.40/6/8

1,150X260X4801,390X345X575

34.5/40---

39/35MDP-M075SGU1

DEFAULT

UH094EAM1CROTARYR410A

880X798X3101,023X891X413

74/8255

-5~43-5~241,800

30157.540

DH105EAMCUH105EAMC

10,00011,0003,8303,850

2.61(D) 2.86(D) 17.50 17.50

9.52(3/8)19.05(3/4)

1/220-240/50

DH105EAMC-

SIROCCO FAN30

0/8/101,150X320X4801,396X424X584

39/46---

39/35MDP-M075SGU1

DEFAULT

UH105EAMCSCROLLR410A

880X931X3201,043X411X1,062

87/9256

-5~43-5~242,600

50307.540

Indoor Unit

Outdoor Unit

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current (Min./Standard/Max.)

Piping Connection

Power Supplyndoor UnitModelPanelFan TypeAir Flow RateExternal Static Pressure (Min./Standard/Max.)Set

Panel

Sound Pressure Level 3)

Drain Pump Kit (Option)Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmAqmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

DH105EAMCUH105GAMC

10,00010,7003,7003,800

2.70(D) 2.82(D)

6.40 6.50

9.52(3/8)19.05(3/4)

3/380~415/50

DH105EAMC-

SIROCCO FAN30

0/8/101,150X320X4801,396X424X584

39/46---

39/35MDP-M075SGU1

DEFAULT

UH105GAMCSCROLLR410A

880X931X3201,043X411X1,062

87/9256

-5~43-5~242,750

50307.540

DH140EAMCUH140GAMC

14,70016,0005,5005,700

2.67(D) 2.81(D)

9.50 10.20

9.52(3/8)19.05(3/4)

3/380~415/50

DH140EAMC-

SIROCCO FAN38

0/8/151,200X360X6501,447X425X769

52/60---

43/38MDP-M075SGU2

DEFAULT

UH140GAMCSCROLLR410A

932X1,128X3751,091X1,286X472

121/13659

-5 ~ 43-5 ~ 243,300

50307.540

Indoor Unit

Outdoor Unit

Page 22: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Floor & Convertible type Air conditionersConvertible installation options, and the unique but functional design adds aestheticatmosphere to your interior while giving efficient cooling and heating.

I Interior DesignNow with more flexibility in placement, the air conditionercan add a stylish element to your room.

INTERIORINTERIORDESIGNDESIGN

INTERIORINTERIORDESIGNDESIGN

Silent ModeIndoor units operate quietly with the leastpossible noise.

Anti-bacteria FilterThe anti-bacteria filter not only traps dust particles, butsuppresses proliferation of molds and bacteria.

BACTERIABACTERIABACTERIABACTERIA

Light Weight UnitThis extremely lightweight design makes maintenanceand installation easy.

LIGHTLIGHTLIGHTLIGHT

Flexible Pipe InstallationThe drain pipe can be installed in 6 different places, so youhave more options in where to place your air conditioner.

Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

Auto ChangeoverThe Auto Changeover automatically selects the operationmode according to the temperature setting.

AUTOAUTOAUTOAUTO

Auto Changeover

42432009 Samsung Ceiling Air Conditioners

Page 23: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

MPI ZoneSamsung's Micro Plasma Ion Zone is a technology that generatesactivated hydrogen and oxygen ions, which exterminates virusesand allergy-causing microbes in the air by neutralizing them andturning into water.

ConsoleUnique design with the two air outlets on top and bottom side of the indoor unit provide more efficientcooling and heating.

Optional Accessories

Elegant Design

Clean PanelStay clean with the smartly designed CleanPanel. This unique panel keeps dust frombeing accumulated so the unit and the roomstays cleaner.

Slim DesignIt can't get any slimmer. This newly introducedconsole type air conditioner is only 199mmthick, the slimmest on the market. Its slimdesign easily integrates the unit into yourdecor.

Silent Operation (23dB)The silent, yet powerful and efficient cooling and heating systemkeeps things more comfortable. Silent mode is available in 4 different operating modes: High / Medium / Low / Silence.

2Way air outletsThere are two separate air outlets for cooling and heating. Havingwarmer air coming out from the bottom part of the air outlet willspread the warm air evenly throughout the room. Stay cooler andwarmer in every corner of your room.

Slim & Smart DesignThis extremely slim design with Clean Panel adds aesthetic value to any interior.

199mm

Black DisplayFunctional art, the touch screen display iselegant while it maximizes the convenienceof control.

INTERIORDESIGNINTERIORINTERIOR

DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

LIGHT WEIGHT UNIT

LIGHTLIGHTLIGHTLIGHT

SILENT MODE

FLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe

InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless

AUTOCHANGEOVERAUTOAUTOAUTOAUTO

44452009 Samsung Ceiling Air Conditioners

MWR-TH01

Individual Controllers

MWR-WS00MWR-WE00

Standard Accessories

Wireless RemoteControllers

Page 24: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Console

Specification | Console

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor Filter(Catechin, Deodorizing)Outdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

JH026EAV1UH026EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

980/2,600/3,600950/3,500/4,600230/670/1,040210/970/1,250

3.88(A)3.61(A)

1.5/3.3/4.91.4/4.7/6.26.35(1/4)9.52(3/8)

1/220~240/50

JH026EAV1-

TURBO FAN8.1

720X620X199810X710X295

15.2/20.3---

38/23DEFAULT

UH026EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950201550

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor Filter(Catechin, Deodorizing)Outdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unitModel

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

JH035EAV1UH035EAV1

990/3,500/4,200990/4,000/4,900250/1,190/1,340210/1,108/1,350

3.21(A)3.61(A)

1.7/5.2/6.21.4/5.3/6.56.35(1/4)9.52(3/8)

1/220~240/50

JH035EAV1-

TURBO FAN9

720X620X199810X710X295

15.2/20.3---

39/24DEFAULT

UH035EAV1SINGLE BLDC

R410A790X548X285938X610X382

32.6/35.447

-10~43-15~24

950201550

JH052EAV1UH052EAV1

1,200/5,000/6,0001,400/5,600/8,200390/1,560/2,030330/1,553/2,900

3.21(A)3.61(A)

2.0/7.8/9.21.7/7.8/13.0

6.35(1/4)12.7(1/2)

1/220~240/50

JH052EAV1-

TURBO FAN11.5

720x620x199810x710x295

16/20.3---

44/25DEFAULT

UH052EAV1SINGLE BLDC

R410A880X638X310

1,023X704X41352/56

49-15~43-20~241,450

5030530

46472009 Samsung Ceiling Air Conditioners

Indoor Unit

Outdoor Unit

Indoor Unit

Outdoor Unit

Page 25: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

CeilingTwo way installation options allow the air coming out from the ceiling or floor.

INTERIORDESIGNINTERIORINTERIOR

DESIGNDESIGNINTERIORINTERIORDESIGNDESIGN

ANTI-BACTERIA FILTERBACTERIABACTERIABACTERIABACTERIA

LIGHT WEIGHT UNIT

LIGHTLIGHTLIGHTLIGHT FLEXIBLE PIPEINSTALLATIONFlexible PipeFlexible Pipe

InstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

WIRELESS REMOTECONTROLWirelessWirelessWirelessWireless

AUTOCHANGEOVERAUTOAUTOAUTOAUTO

Compact but PowerfulSamsung’s ceiling type air conditioner boasts a slim, compactdesign, half the size of its competitors, with cooling powercomparable to competitor’s larger products.

2way InstallationDepending on the space availability and the purposeof the air conditioner, the indoor unit can be installedunder the ceiling or on the floor.

Under Ceiling Floor Standing

48492009 Samsung Ceiling Air Conditioners

Optional Accessories

MWR-WS00 MWR-TH01

Individual Controllers

MR-CH01

Specification | Ceiling

Dimension (Net)Dimension (Gross)Weight (Net/Gross)Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Dimension (Net)Dimension (Gross)Weight (Net/Gross)

Capacity (Min./Standard/Max.)

Power Input (Min./Standard/Max.)

E.E.R

Running Current(Min./Standard/Max.)Piping Connection

Power SupplyIndoor UnitModelPanelFan TypeAir Flow RateSet

Panel

Sound Pressure Level 3)

Indoor FilterOutdoor UnitModelCompressorRefrigerantSet

Sound Pressure LevelTemperature Range

Quantity of Ref.Extension Length (total)Extension Length (elevation)StandardAdditional Ref.

Cooling 1)

Heating 2)

CoolingHeatingCoolingHeatingCoolingHeatingLiquidGas

WxHxDWxHxD

WxHxDWxHxD

High/Low

TypeWxHxDWxHxD

CoolingHeating

Indoor unitOutdoor unit

FH052EAV1UH052EAV1Model

Notes

1) Nominal cooling capacities are based on: Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB, 24°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

2) Nominal heating capacities are based on: Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB, Equivalent refrigerant piping: 7.5m, Level differences: 0m

3) Sound pressure was acquired in a dead room. Thus actual noise level may be different depending on the installation conditions.

- Specifications are subject to change without prior notice for product improvement.

WattsWattsWattsWattsW/WW/WAmpsAmpsmm (inch)mm (inch)Ø/V/Hz

m3/minmmmmkgmmmmkgdB(A)

mmmmkgdB(A)°C°Cgmmmg/m

1,700/5,000/5,6001,700/6,000/8,000480/1,660/1,900430/1870/3050

3.01(B)3.21(C)

2.8/7.8/9.02.4/8.8/14.5

6.35(1/4)12.7(1/2)

1/220-240/50

FH052EAV1-

SIROCCO FAN14.5

1,000X200X6501,074X294X726

22/26---

38/32DEFAULT

UH052EAV1TWIN BLDC

R410A880X638X310

1,023X704X41350/54

49-15~43-20~241,450

5030530

FH070EAV1UH070EAV1

2,000/7,100/8,0002,000/8,000/11,000

590/2,520/2,900450/2,750/3,750

2.81(C)2.91(D)

3.0/11.0/13.02.9/12.5/17.0

6.35(1/4)15.88(5/8)

1/220-240/50

FH070EAV1-

SIROCCO FAN16.0

1,000X200X6501,074X294X726

22/26---

41/36DEFAULT

UH070EAV1TWIN BLDC

R410A880X798X310

1,038X861X41357/63

52-15~43-20~241,900

5030530

FH052EAMCUH052EAMC

5,4006,2001,9202,000

2.61(D)3.10(D)

8.5 8.6

6.35(1/4)12.7(1/2)

1/220-240/50

FH052EAMC-

SIROCCO FAN13.2

1,000X200X6501,074X294X726

22/26---

38/32DEFAULT

UH052EAMCROTARYR410A

880X648X3101,023X744X413

59/6649

-5~43-5~241,500

30157.525

FH070EAM1CUH070EAM1C

6,7007,2002,4802,550

2.70(D)2.82(D)

11.4 11.5

6.35(1/4)15.88(5/8)

1/220-240/50

FH070EAM1C-

SIROCCO FAN14.4

1,000X200X6501,074X294X726

22/26---

41/36DEFAULT

UH070EAM1CROTARYR410A

880X648X3101023X744X413

60/6751

-5~43-5~241,700

30157.540

200%

100%

136%

118% 123%

100%

Size

7.0kW Model

Weight

Smaller Lighter

Indoor Unit

Outdoor Unit

Page 26: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

MDP-E075SEEMDP-E075SEE1MDP-M075SGU3MDP-M075SGU1MDP-M075SGU2

Slim duct

MSP duct

PVC Hose, 2.6kW~7.0kWNew Hose, 10.5kW~14.0kW5.2kW~7.0kW9.4kW~12.5kW14.0kW~17.5kW

Duct Drain Pump

ModelClassification Compatible units Description

PSSMA

P2SMA

PMSMA

P4SMA

Unified Panel

Unified Panel

Unified Panel

Unified Panel

Single, DVM unified Panel

Single, Multi, DVM unified Panel

Single, Multi, DVM unified Panel

Single, Multi, DVM unified Panel

Slim 1Way Cassette

2Way Cassette

Mini 4Way Cassette

4Way Cassette

ModelClassification Compatible units Description

Drain Pump

Panel

MWR-WE00

MWR-WS00

MWR-TH01

MR-CH01

Unified Remote Controller

Unified Remote Controller

Unified Remote Controller

Unified Remote Controller

Individual and group control

Individual and group control

Individual and group control

Simple schedule control

Wired Remote Controller

Wireless Remote Controller

ModelClassification Compatible units Description

Remote Controller

50512009 Samsung Ceiling Air Conditioners

Accessories

Page 27: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

CONTROL SYSTEMS02

52532009 Samsung Ceiling Air Conditioners

Power of control, within your handsSamsung’s smart control system is the most convenient way

to control your system air conditioner. Control systems have

improved one step forward for better usability and

management for you to be able to control your air

conditioner practically anywhere and anytime.

| Control Systems

54

56

58

62

63

64

| Individual Control System

| Centralized Control System

| Integrated Management System

| Guest Room Management System

| DVM Pro

| Accessories

Page 28: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Individual Control SystemErgonomic and innovative remote controllers feature better design, easy grip, large and soft

buttons with easy-to-view displays.

Function Icon

ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING

OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)

GroupGroupGroupGroup

ERROR DISPLAYErrorErrorErrorError

FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter

MWR-WS00 (Premium)• Weekly schedule setting

(Maximum 70 schedules)• Exception date setting• Built-in room temperature

sensor• Clear and bright screen with

LCD backlight• Temperature limit setting• Wireless remote control

restriction• Automatic Stop mode • Sleep and Silent mode• Child lock

Wired Remote Controller

OperationOperationOperationOperation GroupGroupGroupGroup

ErrorErrorErrorError FilterFilterFilterFilter

OperationOperationOperationOperation GroupGroupGroupGroup

ErrorErrorErrorError FilterFilterFilterFilter

MR-CH01

• Simple schedule control• Wide display• Soft touch button

Wireless Remote Controller

OperationOperationOperationOperation FilterFilterFilterFilter

54552009 Samsung Ceiling Air Conditioners

MWR-TH01• Simple schedule control

• Wireless remote controlrestriction

OperationOperationOperationOperation GroupGroupGroupGroup

ErrorErrorErrorError FilterFilterFilterFilter

MWR-WE00 (Multi function)• Unified controller

(A/C, ERV, A/C+ERV)• Different button permission

levels• Weekly schedule setting

(A/C, ERV, A/C+ERV)• Exception date setting• Built-in room temperature

sensor• Clear and bright screen

with LCD backlight• Wireless remote control

restriction• Automatic Stop mode • Sleep and Silent mode• Child lock

Page 29: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

56572009 Samsung Ceiling Air Conditioners

Centralized Control SystemSamsung's centralized control system can control and monitor up to 4,096 individual indoor units and 256 groupsof indoor units simultaneously with great convenience and efficiency.

Function Icon

ON/OFF, OPERATION MODE, FAN SPEED,AIRFLOW, TEMPERATURE SETTING

OperationOperationOperationOperation INDIVIDUAL AND GROUP CONTROL (MAXIMUM 16 INDOOR UNITS)

GroupGroupGroupGroup

ERROR DISPLAYErrorErrorErrorError

FILTER REPLACEMENT ALARM RESETFilterFilterFilterFilter

MCM-A202A• Maximum 16 group controls (Maximum 256 Indoor units)

• Unified/Individual indoor unit control (On/Off)

• Wireless/wired remote control restriction

• Cooling/Heating mode control

• Indoor unit error display

Centralized Controller

MCM-A100

Function Controller

OperationOperationOperationOperation ErrorErrorErrorError FilterFilterFilterFilter

• Control and monitoring ofup to 16 indoor unit groups

To use Function Controller, itrequires to be connected toMCM-A202A

• Communicator betweenindoor/outdoor units and the centralized controller

Interface ModuleMIM-B04A

Page 30: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Integrated Management SystemIntegrated Management System is convenient for managing system air conditioners installed in small and middle-sizedbuildings. It can be managed through the Internet so you can control the air conditioners from anywhere.

Data Management Server

DMS System

Max. 16 units

DMS

58592009 Samsung Ceiling Air Conditioners

Web Server Function• Built-in web server.

• Multiple upper-layer control access with prioritized management.

• Remote access control with the static IP address.Internet

Anytime, Anywhere Control

Cooling Schedule Setup

Power Distribution System• Power distribution to up to 256 indoor units.

• Data query for watt-hour, use time and use ratio.

• File save in Microsoft Excel format.

• 93 days worth of power distribution data storage.

08:00 AM On 10:00 PM Off

External Contact Interface• Full indoor unit control with simple contact input.

(Emergency/Lock)

• State output (Operation/Error) for synchronous

control.

Schedule Control Function• Up to 256 schedule settings.

• Weekly, Daily or 1-Day schedule control.

• Exception date setting.

History Management• Easy service and management with error history.

• Occurrence date, error details, current state.

Building Control System

Rapid Service Response

Error History Monitoring

Fire Control System Error Status Indicator

Operation Restriction

Service

Easy Control & Monitoring• Individual/Group control and monitoring of up to 256 indoor units.

• Operation mode, temperature setting, airflow direction and

fan speed.

• Easy multiple/full indoor unit selection.

• Full room temperature display.

• Error history query based on date.

Enhanced central management• Operation mode lock

• Temperature limit setting

• Wireless / wired remote control restriction

DMS

Easy Control & Monitoring

Web Server Function

Schedule Control Function

Power Distribution System

Building Management System

MIM-D00• Built-in web server for PC-independent management and remote access

control• Multiple upper-layer control access (S-NET 3, S-NET Mini, Web-client)• Individual/Group control of up to 256 indoor units and heat exchange units• Error history management• Weekly/Daily schedule control• Power distribution function• 2 digital inputs, 2 digital outputs• Current time management even during power failure (for 24 hours)• Data storage in non-volatile memory • Emergency stop function with simple contact interface• Operation mode lock• Temperature limit setting

360kWh

460kWh

140kWh

Indoor unit operation state

1. Operation data accumulation andpower distribution

2.Data extract - Excel format

610kWh

180kWh

5th Floor

4th Floor

3rd Floor

2nd Floor

1st Floor

Page 31: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Integrated Management SystemYou can manage a group of buildings with S-NET3 through Data Management Servers that manage each of thebuildings. S-NET3 provides flexible and complete control for a great variety of applications.

• Fully integrated PC management software.

• Up to 16 DMSs connection through the Ethernet.

• Central management of up to 4,096 indoor/heatexchange units.

• Schedule/Zone control.

• Error/Operation history management.

• Power distribution management and analysis.

• Automatic update through the Internet.

S-NET 3

Data Management Server

S-NET 3 System

S-NET 3

Supports 16 DMSs

Max. 16 units

S-NET mini System

• Dynamic compatibility options (DMS, centralized controller, interface module)

• Control and monitoring of up to 256 indoor units• Detailed cycling information monitoring• Schedule function (Weekly, Daily)• USB keyboard support • Error display • 7-inch wide LCD display • Temperature limit setting • Touch screen• Zone control• Child-lock setting• Operation mode lock• External contact control

S-NET mini

Supports 16

InterfaceModules

Supports 16

CentralizedControllers

Supports 4 DMSs

60612009 Samsung Ceiling Air Conditioners

Page 32: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

Guest Room Management SystemThe Guest Room Management System is a smart way to save energy and money. When the Key Tag is in place, the airconditioner is activated. When the Key Tag is removed, the air conditioner switches off. Now you can avoid cooling anunoccupied room and save energy.

MIM-B14• Direct indoor unit control by external contact signal

• Window-synchronized indoor unit control

• Emergency control with simple contact input

• Indoor unit operation/error state output through relay contacts

62632009 Samsung Ceiling Air Conditioners

Key-Tag

On/Off

Window OpenSensor

MalfunctionAlarm

External deviceControl

On/Off On/OffError

Example

DVM - Pro(DVM, FJM, CAC Equipment Selection Software)

DVM-Pro consists of two kinds of software called DVM-Pro Sales and CAD mode.

DVM-Pro Sales mode• Workspace: Creation ‘Project’ & ‚‘Workspace (DVM, FJM, CAC)’

• Indoor Unit: Indoor unit and accessory selection

• Outdoor Unit: Automatic selection and capacity simulation

• Piping: Basic, standard or manual selection with system check

• Wiring: Automatic diagram with communication wiring of indoor/outdoor/control units and electric power meters

• Control system: Automatic control unit selection

• Report: Specifications, diagrams and quotation

Download!www.dvmsystem.com Download Center DVM-Pro

DVM-Pro CAD mode• Quick, easy, precise design

• Compatibility with AutoCAD

• Automatic calculation: Refrigerant & drain pipe size

• Automatic selection: Refnet joint, header & distributor kit

• System check: Installation regulation & refrigerant addition

• Simulation: System capacities

• Easy control system selection

• Automatic report: Piping installation diagram, equipment list & quotation

Contact to Samsung HQ or Distributors for DVM-Pro CAD!

Page 33: 2009 CAC catalog01(EU) - klimainfo.sk Katalog_CAC_2009_0.pdf · Perfect fit for every space A perfect air conditioner is different, it depends on the application and end user. Each

64652009 Samsung Ceiling Air Conditioners

AccessoriesClassification Product Model Image Application Model

IntegratedManagementSystem

ControllerDMS MIM-D00 CAC, FJM, DVM Series, ERV

CAC, FJM, DVM Series, ERV

CAC, FJM, DVM Series

S-NET 3 MST-P3P

S-NET Mini MST-S3W

CentralizedControlSystem

InterfaceModule

CAC, FJM, DVM Series, ERV

CAC, FJM, DVM Series

CAC, DVM, DVM PLUS, DVM HR

MCM-A202AController Centralized Controller

MCM-A100Function Controller

MIM-B04ACentralized Control Interface Module

CAC, DVM Plus II, DVM Plus III, DVM Plus II HR, DVM Plus III HR, Mini DVM (R410A), FJM(Non MH FKEA)

External Contact Interface Module MIM-B14Guest RoomManagementSystem

IndividualControlSystem

ControllerWireless Remote Controller MR-CH01 Cassette, Wall Mounted,

Ceiling, Duct (Receiver needed),Console

Cassette, Wall Mounted, Ceiling, Duct, Console

Cassette, Wall Mounted, Ceiling, Duct, Console

Duct (For Wireless Remote Controller)

Duct (For Wireless Remote Controller)

Cassette, Wall Mounted, Ceiling, Duct, Console

Wired Remote Controller (Premium) MWR-WS00

Wired Remote Controller MWR-TH01

DuctReceiver Kit ofWireless RemoteController

MRK-A00ReceiverofWireless Remote Controller

Receiver Wire MRW-10A

7-day Scheduler MWR-BS00

Cassette, Wall Mounted, Ceiling, Duct, Console

Wired Remote Controller (Multi Function) MWR-WE00

DVM Series : Mini DVM, DVM, DVM PLUS, DVM HR, DVM PLUS II, DVM HR II, DVM PLUS III, DVM PLUS IIIHR

Icon IndexCassette Type Icon

WIDE BLADEWider blades provide moreeven cooling power. WIDEWIDEWIDEWIDE

CEILING SOILINGPREVENTIONNewly designed panel preventsceiling contamination.

HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.

FRESH AIR INTAKE

Optional air intake motorbrings in fresh air from outside.

HIGHHIGHHIGHHIGH

FRESHFRESHFRESHFRESH

QUICK CONNECTIONOF DRAIN PIPEUnique drain pipe connectionis easy to install.

QUICKQUICKQUICKQUICK

SUB DUCT

The Sub Duct makes it easyto provide air conditioning toa nearby smaller space.

SUB DUCTSUB DUCTSUB DUCTSUB DUCT

Duct Type Icon

ANTI-BACTERIA FILTERAnti-bacteria Filter traps dust particles and suppresses proliferationof molds and bacteria.

EASY FILTER CLEANINGFilter cleaning indicator willlet you know when the filterneeds to be cleaned.

HIGH LIFT-UP DRAIN PUMPLift-up condensed water upto 750mm higher than anyother competitor.

SMART PRESSURE CONTROLAdjusts fan speed to provideconstant cooling and heatingperformance.

BACTERIABACTERIABACTERIABACTERIAHIGHHIGHHIGHHIGH

WIRED REMOTE CONTROLLERDefault wired remote controlleris provided.

WiredWiredWiredWired

Control Systems Icon

Floor & Convertible Type Icon

INTERIOR DESIGNThe clean, modern designcomplements any decor.

LIGHT WEIGHT UNITExtremely lightweight, so maintenance and installation is easy.

ANTI-BACTERIA FILTERAnti-bacteria Filter traps dustparticles and suppresses proliferation of molds and bacteria.

INTERIORINTERIORDESIGNDESIGN

INTERIORINTERIORDESIGNDESIGN BACTERIABACTERIABACTERIABACTERIA

AUTO CHANGEOVERAutomatically changes operationmode according to temperaturesetting.

AUTOAUTOAUTOAUTO

LIGHTLIGHTLIGHTLIGHT

FLEXIBLE PIPEINSTALLATIONThe pipe can be installedin 6 different places formore placement options.

SILENT MODEIndoor and outdoor unitoperates silently.

Flexible PipeFlexible PipeInstallationInstallationFlexible PipeFlexible PipeInstallationInstallation

WIRELESS REMOTECONTOLLERDefault wireless remote controlleris provided.

WirelessWirelessWirelessWireless

ON/OFF, OPERATION MODE,FAN SPEED, AIR FLOW, TEMPERATURE SETTING

OperationOperationOperationOperation INDIVIDUAL AND GROUPCONTROL (MAXIMUM 16INDOOR UNITS)

GroupGroupGroupGroup

ERROR DISPLAYErrorErrorErrorError FILTER REPLACEMENT

ALARM RESET

FilterFilterFilterFilter