24
High Performance Exterior Sheathing CertainTeed Est. 1665 2015 ®

2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

H i g h P e r f o r m a n c e E x t e r i o r S h e a t h i n g

CertainTeed

Est. 1665

2015®

Page 2: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

CertainTeed respects the environment through the responsible development of sustainable building products and systems.

By utilizing Building Science,

and by taking a life cycle

perspective, our products

and systems are

manufactured to meet the

high-performance demands

of today’s buildings, as well

as to reach even higher

goals for the future. By

working with others, we’re

demonstrating that we are

genuine advocates of

building responsibly.

2

GlasRoc® Sheathing is a high performance,

water resistant, gypsum-based exterior

sheathing.

GlasRoc Sheathing offers a patented

technology of a high performance polymer

coating on reinforcing glass mat facers.

This unique coating provides a superior

water and UV resistant surface for long term

protection to weather exposures.

The “paperless” glass mat facers are

embedded into a water resistant gypsum core,

and positioned beneath a polymer modified

gypsum surface.

GlasRoc Sheathing offers:

• Long term protection (12 months) to

weather exposure.

•Asuperiorwaterresistantsurfacethat

does not inhibit water vapor permeance.

•Excellentfireresistanceproperties,

and numerous fire rated designs.

•Moldresistance.

•Durability-resistsdelaminationdueto

embedded glass mat in the gypsum core.

• Strength – with enough flexibility to bend

to curved surfaces.

• Alightweightsheathingthatcutslike

regular gypsum board and is easy to handle

andinstall–withminimalskinirritationdue

to embedded glass mats.

•Conformity to design and code requirements.

GlasRoc Sheathing is the next generation

of the industry standard for high-performance,

weather-resistive, gypsum-based sheathing.

Tobackitup,CertainTeedprovidesa:

•12 month limited warranty against exposure

•5yearlimitedwarrantyassuringproduct

performance

•12 year substrate limited warranty in

architecturally-specifiedEIFSystems

High performance polymer coating bonded to a polymer-modified gypsum surface

Reinforcing glass mats embedded beneath a polymer-modified layer of gypsum

Specially formulated water resistant core

A High Performance Exterior Sheathing*

* Covered by U.S. Patent No. 6,524,679; 6,878,321;

6,866,492, and other patents pending.

CoverPhoto:TheAvenueatWestchase,Tampa,FL

Architect:NathanGriffesCuhaci&Peterson

GeneralContractor:SikonConstruction,BocaRaton,FL

Page 3: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com 3

Contents:Introduction.................................................... 2

ApplicationsDiagram .................................... 3

GlasRoc Benefits.......................................... 4

Physical Properties ........................................ 5

ExteriorWallSystems ................................... 6-9

ExteriorDesigns(Arches/Soffits) ................... 10-11

Fire-RatedExteriorWallSystems ................. 12-18

Fire-RatedInteriorSystems .......................... 19-20

Fastening ....................................................... 21

Framing&JointTreatment ........................... 21

Warranty ........................................................ 22

ArchitecturalSpecifications ........................... 23

ContactInformation ....................................... 24

GlasRoc® Sheathing Fire Resistive Applications:

FireResistanceRated MetalStudSystemsSee Pages 12-15

FireResistanceRated WoodStudSystemsSee Pages 16-17

FireResistanceRated Floor/CeilingSystemsSee Page 18

FireResistanceRated SteelBeam&ColumnSee Page 19

GlasRoc Sheathing Applications

NOTE: All drawings are for illustration purposes only.

ExteriorInsulation& FinishSystems(EIFS)

See Page 6

ExteriorArchways, Convex or Concave Surfaces

See Page 10

Conventional StuccoSee Page 8

CavityWallSee Page 7

ExteriorSoffitsSee Page 11

ExteriorCladdingSee Page 9

Page 4: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

GlasRoc® SheathingBenefits

4

Thickness & Type Width Length Edge Standard

1/2” (12.7 mm) GlasRoc® Sheathing 4’ 8’* Square ASTMC1177

5/8” (15.9mm) GlasRoc® Sheathing Type X 4’ 8’* Square ASTMC1177

* Otherlengthsavailable.AskyourCertainTeedsalesrepresentative.

Dimensions

Better Physical Performance

TestedinaccordancewithASTMC1177,

andapplicableASTMC1396sections,

GlasRoc® Sheathing meets or exceeds all

physical property req uirements. Results

showed improved physical performance

compared to glass-faced gypsum

sheathingincluding:

•Reducedhumidifieddeflections

•Superiorflexuralstrengths

•Excellentnail-pullresistance

Enhanced Dimensional Stability

GlasRoc Sheathing will withstand normal

exposure to UV, rain, wind, ice, and snow.

Itisdimensionallystableunderchangesin

temperatureandrelativehumidity.Toback

it up, CertainTeed provides a 12 month

exposure limited warranty.

Excellent Fire Protection

TestinginaccordancewithASTME136

(CAN/ULC-S114)provedthatGlasRoc

Sheathing, with its polymer coating, is

noncombustible and offers superior fire

performance compared to paper-faced

sheathings.Ithasazeroflamespreadand

zerosmokedevelopedindex when tested per

ASTME84(5/5whentestedperCAN/ULC-S102)

for surface burning characteristics.

GlasRoc Sheathing Type X is UL and ULC

ClassifiedforFireResistanceforuseinfire-

rateddesigns.(ULandULCDesignation-

TypeEGRGorGlasRoc).

Easy to Handle and Install

GlasRoc Sheathing is handled and installed

likeregularpaper-facedsheathing.In

addition,it:

•Canbescoredandcutwithastandard

utilityknife.Nospecialtoolsrequired.

•Snapsfreeafterscoringonlytheface.

•Attachestoframingwiththesame

fasteners used for paper-faced gypsum

sheathing.Nospecialfastenersrequired.

•Iseasiertohandlebecauseskin

irritationsareminimizedduetothe

embedded glass mats and our innovative

polymer coating.

•Hasuniformfieldandedgehardness,

makingtrimming&fasteningquick

and easy.

Long Term Protection to

Weather Exposure

GlasRoc Sheathing, with its homogenous

water resistance throughout the board,

offerssuperiorfreeze/thawresistance.It

will withstand exposure to UV, rain, wind,

iceandsnow.Tobackitup,CertainTeed

provides a 12 month exposure limited

warranty. GlasRoc Sheathing provides

enhanced surface liquid water resistance

while allowing the building’s vapor drive to

be unimpeded.

Mold Resistance

BecauseGlasRocSheathingcontains

no starches or sugars, it will resist

mold growth. Whentestedin accordance

withASTMD3273,GlasRocSheathing

exhibited no evidence of mold or fungal

growthafteraperiodof28daysof

exposure,yieldingaratingof10.

Increased Durability

GlasRoc Sheathing resists delamination

because the glass mats are embedded

into the panel, creating a more durable,

dimensionally stable panel.

Standards and Code Compliance

GlasRoc Sheathing conforms to

ASTMC1177,applicableASTMC1396and

CAN/CSA-A82.27standards.

Installationstandards,whereapplicable,are

GypsumAssociationPublicationGA-253,

GA-216andASTMC1280forgypsum

sheathing and soffits.

•NYCMEA312-03-M

•CCMCEvaluationListing#13095-L

•ULEvaluationReportULER3660-1

•OntarioMinisterRulingNo:05-17-141

(13095-R)

Page 5: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

Physical Properties High Performance Sheathing

5

Properties

Products-1/2”(12.7mm) Products-Fire-Rated 5/8”(15.9mm) Test

Method/ReferenceGlasRoc®

Sheathing

GlasRoc®

Sheathing Type X

Physical Characteristics:

NominalWidthInches(mm) 48(1219) 48(1219) ASTMC473

StandardLengthFeet(mm) 8*(2438) 8*(2438) ASTMC473

Weight-Lbs/SquareFoot(Kg/m2) 1.9(9.3) 2.4 (11.7) ASTMC473

FaceSurface Polymer/Gypsum Polymer/Gypsum -

Pliability:

BendingRadius- Dry,Lengthwise,Feet(mm)

4 (1219)

6 (1829) -

Strength:

RackingStrength-UltimateValue Lbs/Lin.Ft.-(kN/m) 540(7.88) 654(9.54) ASTME72

ParallelFlexuralStrength-Ibf(N) ≥80 (356) ≥100 (445) ASTMC473

Sag Resistance:

HumidifiedDeflection(Sag)-Inches(mm) 3/32(2.4) 1/16(1.6) ASTMC473

Permeance - perms(ng/Pa•s•m2) 26(1500) 21(1200) ASTME96

Thermal Resistance:

“R” Value - sq.ft.•h•°F/Btu(K•m2/W) 0.45(0.079) 0.57(1.00) ASTMC518

Fire Performance:

FlameSpread/ SmokeDeveloped

0/05/5

0/05/5

ASTME84 CAN/ULC-S102

Combustibility: Noncombustible NoncombustibleASTM E136

CAN/ULC-S114

Dimensional Stability:

Thermal Coefficient of Linear Expansion-in./in./°F(mm/mm/°C)

9.3X10 -6

(16.7 X10 -6)9.3X10 -6

(16.7 X10 -6)ASTME228

Mold Resistance:

MoldResistanceRating** 10** 10** ASTMD3273

* Otherlengthsavailable.AskyourCertainTeedsalesrepresentative.**Nomoldgrowthdetected.Note10ishighestratingpossible.

Water Vapor Transmission:

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Page 6: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

6

Superior Strength

GlasRoc® Sheathing integrally bonds its

polymer face coating to the moisture

resistant core, resulting in a superior

protective sheathing that will perform in all

climates.

Dimensional Stability

GlasRoc Sheathing resists delamination,

rippling,bucklingandsaggingcaused

by environmental conditions, such as

freeze/thaw,heatandhumidity,anddirect

UV exposure. This technology, with its

embeddedglassmats,makesGlasRoc

Sheathing state-of-the-art, and will provide

aflatanduniformsubstrateforEIFS

applications.

Moisture Resistance

Whenproperlyinstalled,GlasRoc

Sheathingblocksliquidwaterwithout

inhibiting water vapor transmission.

The result is a protective surface that

is extremely resistant to water damage.

Easy to Install

GlasRoc Sheathing is easier to handle

andinstall.Nospecialtoolsare

required. Score it with a standard utility

knife.Installitwithstandardsheathing

fasteners.

Referenced Standards

• ASTMC514:SpecificationforNails

fortheApplicationofGypsumBoard

• ASTMC954:SpecificationforSteelDrill

ScrewsfortheApplicationofGypsum

PanelProductsorMetalPlasterBases

to Steel Studs from

0.33in.(0.84mm)to0.112in.

(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecificationfor

GlassMatGypsumSubstrateforUse

as Sheathing

• ASTMC1280:StandardSpecificationfor

ApplicationofGypsumSheathing

• ASTMC1397:PracticeforApplicationof

ClassPBExteriorInsulationandFinish

Systems

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

• ASTME119(CAN/ULC-S101):Test

MethodforFireTestsofBuilding

ConstructionandMaterials

Finish Coat

Base Coat

Embedded Reinforced Mesh

EPS Insulation

Bonding Adhesive

Insulation

Metal or wood framing

GlasRoc® Sheathing

As a component of an EIF System, GlasRoc® Sheathing offers:

• Superior water shed and surface

water resistance.

• Excellenttotalwaterabsorption

resistance.

• TwelvemonthresistancetoUV

and environmental exposure.

• Improvedinsulationadhesion

due to integrated board surface.

• Approvedsubstratebythemajor

EIFSmanufacturers.

GlasRoc® SheathingExterior Wall Systems

Exterior Insulation andFinish Systems (EIFS) Applications

Page 7: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

7

GlasRoc® Sheathing offers a protective,

smooth, water-resistant application

surface which will withstand water

penetration into the stud cavity, so a

separate weather-resistant barrier may

not be necessary, unless required by

local code. To best prevent air and water

intrusion (when a separate water-resistive

barrier is not required by local codes),

thejointsshouldbetreatedwithexterior

siliconecaulkandglassmeshtape.

Consultwithauthorityhavingjurisdiction,

prior to installation regarding local

requirements.

Installation Recommendations

Wheninstallingabrickorstoneveneerover

GlasRocSheathing,attachthebrick

or masonry ties through the GlasRoc

Sheathing to the structural framing

supports. Consult the manufacturer or local

building code authority for proper spacing

andinstallationofbrickormasonryties.

Referenced Standards

• ASTMC514:SpecificationforNails

fortheApplicationofGypsumBoard

• ASTMC954:SpecificationforSteelDrill

ScrewsfortheApplicationofGypsum

PanelProductsorMetalPlasterBases

toSteelStudsfrom0.33in.(0.84mm)

to0.112in.(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecification

forGlassMatGypsumSubstratefor

Use as Sheathing

• ASTMC1280:StandardSpecification

forApplicationofGypsumSheathing

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

• ASTME119(CAN/ULC-S101):Test

MethodforFireTestsofBuilding

ConstructionandMaterials

Cavity Wall Applications

GlasRoc® Sheathing

Metal or wood framing

Flashing

Brick Veneer

Wall Tie

Air space

Insulation

Weep Holes

Water-resistive barrier as required by local code

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Page 8: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

8

GlasRoc® Sheathing’s integral coated

surface with its high surface bond

strength provides an excellent water-

resistant surface for conventional stucco

applications. The treated core adds to

the water-resistive performance of the

product. Conventional stucco systems

rely on the structural soundness of the

sheathing component to which they are

applied. GlasRoc Sheathing offers physical

properties superior to competitive gypsum

sheathingproductsinthemarket.Itis

manufactured to meet or exceed the

physical property requirements outlined in

ASTMC1177.

Installation Recommendation

Inaconventionalstuccosystem,metallath

or other specified self-furring components

should be attached to the framing

members through the GlasRoc Sheathing,

after the appropriate water-resistive barrier

and flashing is installed. Use appropriate

jointtreatmentasrequiredbylocalbuilding

code.Applythestucco,asrecommended

by the manufacturer.

Referenced Standards

• ASTMC514:SpecificationforNailsfor

theApplicationofGypsumBoard

• ASTMC954:SpecificationforSteelDrill

ScrewsfortheApplicationofGypsum

PanelProductsorMetalPlasterBases

toSteelStudsfrom0.33in.(0.84mm)

to0.112in.(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecificationfor

GlassMatGypsumSubstrateforUse

as Sheathing

• ASTMC1280:StandardSpecificationfor

ApplicationofGypsumSheathing

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

• ASTME119(CAN/ULC-S101):Test

MethodforFireTestsofBuilding

ConstructionandMaterials

Flashing

Conventional Stucco

Metal or wood framing

Insulation

GlasRoc® Sheathing

Metal Lath

Water-resistive Barrier

Conventional Stucco Applications

GlasRoc® SheathingExterior Wall Systems

Page 9: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

9

There are numerous exterior claddings

availabletoday,fromshinglestoshakes

to a multitude of siding alternatives.

GlasRoc® Sheathing is an excellent choice

for any of these applications. Simply install

GlasRoc Sheathing and apply the preferred

exterior cladding, per the manufacturer’s

recommendations.Dependingonlocal

buildingcodes,ajointtreatment,water-

resistive barrier, building felt, or building

wrap may be necessary.

Referenced Standards

• ASTMC514:SpecificationforNails

fortheApplicationofGypsumBoard

• ASTMC954:SpecificationforSteelDrill

ScrewsfortheApplicationofGypsum

PanelProductsorMetalPlasterBases

toSteelStudsfrom0.33in.(0.84mm)

to0.112in.(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecificationfor

GlassMatGypsumSubstrateforUse

as Sheathing

• ASTMC1280:StandardSpecificationfor

ApplicationofGypsumSheathing

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

• ASTME119(CAN/ULC-S101):Test

MethodforFireTestsofBuilding

ConstructionandMaterials

Exterior Cladding

Metal or Vinyl Siding

Fiber-Cement Siding

Wood Siding

GlasRoc® Sheathing

Insulation

Metal or wood framing

Shingle orShake Siding

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Water-resistive barrier as required by local code

Page 10: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

10

Exterior Archways, Exterior Concave & Convex Surfaces

2” (50 mm) Glass Mesh Tape

Finish Coat

Base Coat

GlasRoc® Sheathing

Refer to finish system

manufacturer for glass mesh

reinforcement requirements.

GlasRoc® Sheathing is engineered for

use in curved exterior gypsum board

applications. There is no need to score or

moisten the board to bend it. To prevent

flat areas in the curved surface, framing

should be positioned at a maximum

spacingof6”(150mm).

ConsulttheGypsumAssociationdocument

GA-226forframingrecommendations.

Application to Archways

GlasRoc Sheathing can be installed in an

archway or on a concave or convex surface

by applying pressure onto the board to fit

the radius and then holding it firmly in place

while fastening it to the framing members.

To best seat the product in tight radius

applications, temporarily install a stop at

one end of the framed radius to serve as

arestraintsupport.Installtheproductwith

coated side out with one of the width ends

placed flush against the temporary stop

and secure with fasteners, one framing

member at a time. Repeat until the product

has been secured to all framing members.

Fastenersshouldbespacednogreater

than8”(200mm)apart.

Referenced Standards

• ASTMC954:SpecificationforSteel

DrillScrewsfortheApplicationof

GypsumPanelProductsorMetal

PlasterBasestoSteelStudsfrom

0.33in.(0.84mm)to0.112in.

(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecificationfor

GlassMatGypsumSubstrateforUseas

Sheathing

• ASTMC1280:StandardSpecificationfor

ApplicationofGypsumSheathing

• ASTMC1397:PracticeforApplicationof

ClassPBExteriorInsulationandFinish

Systems

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

SheathingBoard Thickness

Tested-Bent Lengthwise Radii

1/2”(12.7mm) GlasRoc® Sheathing 4’-(1219mm)

5/8”(15.9mm) GlasRoc® Sheathing Type X 6’-(1829mm)

Recommended Lengthwise Bending Radii

GlasRoc® SheathingExterior Designs / Arches & Soffits

Page 11: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

11

Finish Coat

GlasRoc® Sheathing is a superior

product for a flat ceiling entryway,

exterior ceiling, or a soffit assembly,

due to its ability to resist the deteriorating

effects of moisture and humidity.

The industry defines the amount of

permissiblesagginginahorizontal

application as humidified deflection.

ThereareseveralASTMStandard

Specifications that define a maximum

allowable humidified deflection including

ASTMC1396andASTMC1177.Of these,

ASTMC1177hasthemoststringent

requirements.NotehowGlasRoc®

Sheathing performs.

Installation Recommendations

for Exterior Ceilings & Soffits

Use GlasRoc Sheathing in exterior ceiling

and soffit systems where weather-resistant

performance is critical, including but not

limitedto,ceilings/soffitswithfinished

jointsandceilings/soffitswithoutinsulation.

Installtheproductlikeastandard

gypsumexteriorsoffitboard.Fastenthe

product to the framing members using the

recommendationsspecifiedinGA-216

andASTMC840.Finishingis

accomplishedwitheither;1)Direct-

AppliedExteriorFinishSystem(DEFS)per

the manufacturer’s specifications, or 2)

applying nominal 2” glass mesh drywall

tapeand90minutesetting-typejoint

compoundontheboardjoints,skim-

coating the entire surface of the ceiling

soffit with a setting-type compound and

priming and painting with exterior grade

primer and paint per the manufacturer’s

recommendations.

Referenced Standards

• ASTMC514:SpecificationforNails

fortheApplicationofGypsumBoard

• ASTMC931:StandardSpecification

forExteriorGypsumSoffitBoard

• ASTMC840:StandardSpecificationfor

ApplicationandFinishingofGypsumBoard

• ASTMC954:SpecificationforSteelDrill

ScrewsfortheApplicationofGypsum

PanelProductsorMetalPlasterBases

toSteelStudsfrom0.33in.(0.84mm)

to0.112in.(2.84mm)inThickness

• ASTMC1002:StandardSpecification

forSteelDrillScrewsfortheApplication

ofGypsumPanelProductsorMetal

PlasterBases

• ASTMC1177:StandardSpecification

forGlassMatGypsumSubstratefor

Use as Sheathing

• ASTMC1397:PracticeforApplication

ofClassPBExteriorInsulationand

FinishSystems

• ASTME84(CAN/ULC-S102):

TestMethodforSurfaceBurning

CharacteristicsofBuildingMaterials

• ASTME96:TestMethodsforWater

VaporTransmissionofMaterials

Properties1/2”(12.7mm)

GlasRoc Sheathing

1/2”(12.7mm) Gypsum Soffit

Board

5/8”(15.9mm) GlasRoc

Sheathing Type X

5/8”(15.9mm) Gypsum Type X

SoffitBoard

ASTM TESTMETHOD

Surface Polymer Paper Polymer Paper

Humidified Deflection(Sag) 3/32”(2.4mm) 7/8”(22mm) 1/16”(1.6mm) 1/2”(13mm) C473

GlasRoc® Sheathing in Exterior Ceiling & Soffit Applications

Exterior Soffit

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

GlasRoc® Sheathing

Base Coat with Embedded Reinforced Mat

Flat Ceiling Entryways, Exterior Ceilings & Soffits

Water Absorption <10% 40% <10% 40% C473

Page 12: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

12

GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems

Reference: UL Design U465

24” (600 mm)

5/8” (15.9 mm)GlasRoc® Sheathing Type X

3-5/8” (92 mm) Steel Studs

3-5/8” (92 mm) Steel Track

1-Hour Fire-Resistance Rating

Cavity thickness ..... 3-5/8” (92 mm)

Wall thickness ......... 4-7/8” (124 mm)

Weight ..................... 6 psf (29 kg/m2)

Steel Stud System

5/8” (15.9 mm) CertainTeed® Type X gypsum board

3-1/2” (89 mm) Glass Fiber or Mineral Wool Insulation

(optional)

5/8"(15.9mm)panelswithsquareortaperededges,appliedverticallyorhorizontally.

Verticaljointscenteredoverstudsandstaggeredonestudcavityonoppositesidesof

stud.Horizontaledgejointsandhorizontalbuttjointsonoppositesidesofstudsneed

notbestaggeredorbackedbysteelframing.Panelsattachedtosteelstudsandfloor

runner with 1"(25mm)TypeSsteelscrewsspaced8"(200mm)o.c.whenapplied

horizontally,or8"(200mm)o.c.alongverticalandbottomedgesand12"(300mm)

inthefieldwhenpanelsareappliedvertically.Whenusedinwidthsotherthan

48"(1200mm),panelsaretobeinstalledhorizontally.

Page 13: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

13

5/8” (15.9 mm)GlasRoc ® Sheathing Type X

3-1/2” (89 mm) Glass Fiber or Mineral Wool Insulation

2-1/2” (64 mm) Steel Studs

2-1/2” (64 mm) Steel Track

5/8” (15.9 mm) CertainTeed®

Type X gypsum board

24” (600 mm)

Steel Stud System

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

2-Hour Fire-Resistance Rating

Cavity thickness ..... 2-1/2” (64 mm)

Wall thickness ......... 5” (127 mm)

Weight ..................... 11 psf (54 kg/m2)

Interior

Installinsulationbetweenstuds.Applya

baselayerof5/8”(15.9mm)CertainTeed®

Type X gypsum board vertically to interior

sidewith1”(25mm)TypeSsteelscrews

spaced16”(400mm)o.c.alongedgesand

inthefield.Jointsmustbeoffsetfrom

jointsontheoppositeside.

Applyafacelayerof5/8”(15.9mm)

CertainTeed Type X gypsum board vertically

overbaselayerwith1-5/8”(41mm)

Type S steel screws. Space fasteners 16”

(400mm)o.c.alongedgesand12”

(300mm)o.c.alongfloorandceiling

runners.Jointsmustbeoffsetfromjointsin

theunderlyinglayer.Tapeandfinishjoints.

Reference: UL Design U411

Exterior

Applyabaselayerof5/8”(15.9mm)

GlasRoc® Sheathing Type X vertically to

exteriorsidewith1”(25mm)TypeSsteel

screwsspaced16”(400mm)o.c.along

edgesandinthefield.Jointsmustbe

offsetfromjointsontheoppositeside.

Applyafacelayerof5/8”(15.9mm)

GlasRoc Sheathing Type X vertically over

baselayerwith1-5/8”(41mm)TypeS

steelscrews.Spacefasteners16”(400

mm) o.c. along edges and field and 12”

(300mm)o.c.alongthefloorandceiling

runners.Jointsmustbeoffsetfromjointsin

the underlying layer.

Page 14: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

14

1-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 4-3/4” (121 mm)

Weight ..................... 6 psf (29 kg/m2)

Interior

Installinsulationbetweenstuds.Applyone

layerof5/8”(15.9mm)CertainTeed® Type

X gypsum board vertically to interior side

with1”(25mm)TypeS-12steelscrews

spaced12”(300mm)o.c.alongedges

andinthefield.Jointsmustbeoffsetfrom

jointsontheoppositeside.Tapeandfinish

joints.

24” (600 mm)

5/8” (15.9 mm)GlasRoc® Sheathing Type X

3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation

3-1/2” (89 mm) Steel Studs

3-1/2” (89 mm) Steel Track

Reference: UL Design U425(Load-Bearing)

Steel Stud System

5/8” (15.9 mm) CertainTeed®

Type X gypsum board

GlasRoc® Sheathing Type X Exterior Wall / Fire-Rated Systems

Exterior

Applyonelayerof5/8”(15.9mm)

GlasRoc® Sheathing Type X vertically to

exteriorsidewith1”(25mm)screws

spaced12”(300mm)o.c.alongedges

andinthefield.Jointsmustbeoffset

fromjointsontheoppositeside.

Page 15: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

15

2-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 6” (150 mm)

Weight ..................... 11 psf (54 kg/m2)

Interior

Installinsulationbetweenstuds.Applyone

layerof5/8”(15.9mm)CertainTeed® Type

Xgypsumboardverticallywith1”(25mm)

Type S-12 steel screws spaced 12”

(300mm)o.c.alongedgesandinthefield.

Jointsmustbeoffsetfromjointsonthe

opposite side.

Applyafacelayerof5/8”(15.9mm)

CertainTeed Type X gypsum board

verticallywith1-5/8”(41mm)TypeS-12

steelscrewsspaced12”(300mm)o.c.

alongedgesandinthefield.Jointsmust

beoffsetfromjointsintheunderlyinglayer.

Tapeandfinishjoints.

Reference: UL Design U425(Load-Bearing 80% of Design)

5/8” (15.9 mm) GlasRoc® Sheathing Type X

3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation

3-1/2” (89 mm) Steel Studs

3-1/2” (89 mm) Steel Track

5/8” (15.9 mm) CertainTeed®

Type X gypsum board

24” (600 mm)

Steel Stud System

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Exterior

Applyabaselayerof5/8”(15.9mm)

GlasRoc® Sheathing Type X vertically with

1”(25mm)TypeS-12steelscrewsspaced

12”(300mm)o.c.alongedges

andinthefield.Jointsmustbeoffset

fromjointsontheoppositeside.

Applyafacelayerof5/8”(15.9mm)

GlasRoc Sheathing Type X vertically with

1-5/8”(41mm)TypeS-12steelscrews

spaced12”(300mm)o.c.alongedges

andinthefield.Jointsmustbeoffsetfrom

jointsintheunderlyinglayer.

Additional UL Design Listings for

Steel Stud Systems:

U017,U405,U417,U418,U420,U421,

U422,U434,U442,U445,U450,U460,

U466,U467,U473,U475,U485,U487,

U494,U501,U502,U504,U505,U506,

U510,U512,U615,U617,U622,U623,

U626,V417,V419,V469andV486.

Additional ULC Design Listings for

Steel Stud Systems:

W412,W447,W449,W456andW465.

Additional GA-600 Listings for Steel

Stud Systems:

GAFileNo.WP7210,WP8006,WP8203,

WP9020,WP9200andWP9205.

Page 16: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

16

5/8” (15.9 mm)GlasRoc ® Sheathing Type X

2” x 4” (38 mm x 89 mm)Wood Studs

2” x 4” (38 mm x 89 mm) Wood Plates

24” (600 mm)

5/8” (15.9 mm) CertainTeed® Type X gypsum board

3-1/2” (89 mm) Glass Fiber orMineral Wool Insulation

Reference: UL Design U3091-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 4-3/4” (121 mm)

Weight ..................... 7 psf (34 kg/m2)

Interior

Installinsulationbetweenstuds.Applyone

layerof5/8”(15.9mm)CertainTeedType

Xgypsumboardwith1-7/8”(48mm)nails

spaced7”(175mm)o.c.alongedgesand

inthefield.Jointsmustbeoffsetfrom

jointsontheoppositeside.Tapeand

finishjoints.

Exterior

Applyonelayerof5/8”(15.9mm)GlasRoc

SheathingTypeXwith1-7/8”(48mm)

nailsspaced7”(175mm)o.c.alongedges

andinthefield.Jointsmustbeoffsetfrom

jointsontheoppositeside.

Wood Stud System

5/8” (15.9 mm)GlasRoc ® Sheathing

Type X

3-1/2” (89 mm) Glass Fiber or Mineral Wool

Insulation

2” x 4” (38 mm x 89 mm)

Wood Studs

2” x 4” (38 mm x 89 mm) Wood Plates

16”(400 mm)

5/8” (15.9 mm) CertainTeed®

Type X gypsum board

Reference: UL Design U3051-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 4-3/4” (121 mm)

Weight ..................... 7 psf (34 kg/m2)

Interior

Installinsulationbetweenstuds.

Applyonelayerof5/8”(15.9mm)

CertainTeed® Type X gypsum board

vertically or horizontallywith1-7/8”

(48mm)nailsspaced7”(175mm)o.c.

alongedgesandinthefield.Jointsmust

be offset from jointsontheoppositeside.

Tape andfinishjoints.

Exterior

Applyonelayerof5/8”(15.9mm)GlasRoc®

SheathingTypeXverticallyorhorizontally

with1-7/8”(48mm)nailsspaced7”(175mm)

o.c.alongedgesandinthefield.Jointsmust

beoffsetfromjointsontheoppositeside.

Wood Stud System (Load-Bearing)

GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems

Page 17: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

17

2-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 6” (152 mm)

Weight ..................... 12 psf (59 kg/m2)

Interior

Applyabaselayerof5/8”(15.9mm)

CertainTeed® Type X gypsum board

verticallyorhorizontallywith1-7/8”(48mm)

nailsspaced6”(150mm)o.c.alongedges

andinthefield.Jointsmustbeoffsetfrom

jointsontheoppositeside.Verticaljoints

must be located over framing members.

Applyafacelayerof5/8”(15.9mm)

CertainTeed Type X gypsum board vertically

orhorizontallywith2-3/8”(60mm)nails

spaced8”(200mm)o.c.alongedgesandin

thefield.Jointsmustbeoffsetfromjointsin

theunderlyinglayer.Tapeandfinishjoints.

Exterior

Applyabaselayerof5/8”(15.9mm)

GlasRoc® Sheathing Type X vertically

orhorizontallywith1-7/8”(48mm)nails

spaced6”(150mm)o.c.alongedgesand

inthefield.Jointsmustbeoffsetfromjoints

ontheoppositeside.Verticaljointsmustbe

located over framing members.

Applyafacelayerof5/8”(15.9mm)

GlasRoc Sheathing Type X vertically or

horizontallywith2-3/8”(60mm)nails

spaced8”(200mm)o.c.alongedges

andinthefield.Jointsmustbeoffset

fromjointsintheunderlyinglayer.

Tapeandfinishjoints.

Wood Stud System (Load-Bearing)

5/8” (15.9 mm)GlasRoc®

Sheathing Type X

2” x 4” (38 mm x 89 mm)Wood Studs

2” x 4” (38 mm x 89 mm) Wood Plates

5/8” (15.9 mm) CertainTeed® Type X gypsum board

16” (400 mm)

Reference: UL Design U301

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Additional UL Design Listings for Wood Stud Systems:

U326,U329,U330,U332,U337,U338,U339,U341,U342,U344,

U354,U355,U356,U357,U358,U360,U374,U376,U391andV314.

Additional GA-600 Listings for Wood Stud Systems:

GAFileNo.WP8105,WP8109,WP8111,WP8126,WP8130,

WP8410,WP8415,WP8416andWP8420.

Page 18: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

18

GlasRoc® Sheathing Type XExterior Wall / Fire-Rated Systems

Additional UL Design Listings for Wood Stud Systems:

U326,U329,U330,U332,U337,U338,U339,U341,U342,U344,

U354,U355,U356,U357,U358,U360,U374,U376,U391andV434.

Additional ULC Design Listings for Wood Stud Systems:

W310andW313.

Additional GA-600 Listings for Wood Stud Systems:

GAFileNo.WP8105,WP8109,WP8111,WP8126,WP8130,

WP8410,WP8415,WP8416andWP8420.

2-Hour Fire-Resistance Rating

Cavity thickness ..... 3-1/2” (89 mm)

Wall thickness ......... 10” (254 mm)

Interior

Installinsulationbetweenstuds.

Applyabaselayerof5/8”(15.9mm)

CertainTeed® Type X gypsum board

verticallyorhorizontallywith1-7/8”

(48mm)nailsspaced8”(200mm)o.c.

Verticaljointsmustbelocatedover

framing members.

Applyafacelayerof5/8”(15.9mm)

CertainTeed Type X gypsum board

verticallyorhorizontallytotheinterior

sidewith2-3/8”(60mm)nailsspaced

8”(200mm)o.c.Jointsmustbeoffset

fromjointsintheunderlyinglayer.Tape

andfinishjoints.

Exterior

Applyonelayerof1/2”(12.7mm)

GlasRoc® Sheathinghorizontallyto

theexteriorsidewith1-3/4” (44 mm)

roofing nails spaced 6” (150mm) o.c.

Verticaljointsmustbelocatedover

framing members and staggered.

Wood Stud System

3-1/2” (89 mm)Glass Fiber orMineral Wool

Insulation

Clay Face Bricks

1/2” (12.7 mm) GlasRoc® Sheathing

2” x 4” (38 mm x 89 mm)Wood Studs

2” x 4” (38 mm x 89 mm) Wood Plates

5/8” (15.9 mm)CertainTeed® Type X

gypsum board

16”(400 mm)

Air Space

Reference: UL Design U302

Page 19: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

19

GlasRoc® Sheathing Type XFire-Rated / Floor & Ceiling Systems

1-Hour Fire-Resistance Rating

Flooring

2”(51mm)3000psi(21MPa)

compressive strength normal weight

concretepouredoversteeldeck.

Ceiling

Fastensteelfurringchannelstojoists

24”(600mm)o.c.withdoubletiewires,

except12”(300mm)o.c.atendjoints.

SeeDetailA.Adjoininglengthsofchannels

lapped2’-6”(750mm).

Applyonelayerof5/8”(15.9mm)GlasRoc®

Sheathing Type X with the long dimension

perpendicular to the furring channels with

1”(25mm)TypeSsteelscrewsspaced

12”(300mm)o.c.Locatescrews1/2”

(12.7 mm) from edges and ends of board.

Reference: UL Design L5011-Hour Fire-Resistance Rating

Thickness ........... 11” (279 mm)

Weight ................ 13.5 psf (66 kg/m2)

Framing

Setjoists16”(400mm)o.c.Cross-brace

and firestop, as required.

Flooring

Applysubflooringwithfacegrain

perpendiculartojoistwithjointsstaggered.

Finishedflooringwoodstructuralgrade

T&GDouglasFirplywoodwithface

grainperpendiculartojoistswithjoints

staggered.

Applyonelayerof5/8”(15.9mm)GlasRoc

Sheathing Type X with the long dimension

perpendiculartojoistswith1-7/8”(48mm)

nails spaced 6” (150mm) o.c.

Finishandtapejoints.

Detail A

24”(600 mm)

3/8” (9.5mm)

5/8” (15.9 mm) GlasRoc® Sheathing Type X

Steel Joist

Steel Furring Channel

24” (600 mm)

Reference: UL Design G501

5/8” (15.9 mm) GlasRoc® Sheathing Type X

Firestopped

Subflooring2” x 10” (38 mm x 235 mm)Wood Joists

1” x 3” (19 mm x 64 mm)Cross Bridging

16”(400 mm)

Additional UL Design Listings for Floor-Ceiling Systems

SteelJoistFloor-Ceiling:G520andG531.WoodJoistFloor-Ceiling:L508,L591.

Additional ULC Design Listings for Floor-Ceiling Systems

M500.

Additional GA-600 Listings for Floor-Ceiling and Roof-Ceiling Systems

SteelJoistFloor-Ceiling:GAFileNo.FC1130,FC2116,FC2120,FC4490andFC4750.

WoodJoistFloor/Roof-Ceiling:GAFileNo.FC5310,FC5406,FC5407,FC5408,FC5420,

FC5600,FC5725,FC5750,FC5751,RC2601,RC2602,RC2750andRC2751.

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Page 20: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

20

GlasRoc® Sheathing Type XFire-Rated / Beam & Column Systems

2-Hour Fire-Resistance Rating

STEEL BEAM

Attachchannelstosteeldeckwith1/2”

(12.7 mm) Phillips pan head screws spaced

12”(300mm)o.c.Fabricatechannel

bracketsbycuttingnotchesinchannelat

location of corners and fold channel to form

U-bracketoftherequiredsize.Aminimum

1/2”(12.7mm)clearanceisrequiredat

sides and bottom of the beam.

Attachchanneltoangle24”(600mm)

o.c.,with1/2”(12.7mm)Phillipspanhead

screws. Place steel corner angle at lower

cornersofU-brackets.Applyabaselayer

of5/8”(15.9mm)GlasRoc® Sheathing Type

Xwith1-1/4”(32mm)Phillipspanhead

screwsspaced16”(400mm)o.c.Apply

afacelayerof5/8” (15.9mm) GlasRoc

SheathingTypeXwith1-3/4”(44mm)

Phillipspanheadscrewsspaced8”(200

mm)o.c.Jointsmustbeoffsetfromthe

jointsintheunderlayinglayer.Attachcorner

beadtocorners.Tapeandfinishjoints.

2-Hour Fire-Resistance Rating

STEEL COLUMNS

Position steel studs at column corners.

Steel studstobe1/2”(12.7mm)less

than assembly height.

Applyabaselayerof5/8”(15.9mm)

GlasRoc Sheathing Type X vertically with

1”(25mm)Phillipspanheadscrews

spaced24”(600mm)o.c.Applyaface

layerof5/8”(15.9mm)GlasRoc Sheathing

Type X vertically around the perimeter with

1-3/4”(44mm)Phillipspanheadscrews

spaced12”(300mm)o.c.Applycorner

beadwith1-5/8”(41mm)screwsspaced

12”(300mm)o.c.Tapeandfinishjoints.

5/8” (15.9 mm) GlasRoc® Sheathing Type X

Steel Beam Minimum(W8 x 24) W200 x 36 Steel Corner Bead

Steel Angle

Steel Channel

Steel Floor Unit

Concrete Slab

Finishing

Reference: UL Design N502

Reference: UL Design X528

Diagram A: WF

Additional UL Design Listings for Beam & Column Systems

BeamProtection:N501,N502andN505.ColumnProtection:X508,X516,

X517,X525andX526.

Additional GA-600 Listings for Beam & Column Systems

BeamProtection:GAFileNo.BM2120andBM2130.ColumnProtection:

GAFileNo.CM1850,CM1851,CM2017,CM2020,CM2120,CM3115,

CM3116,CM3120,CM4110andCM4600.

5/8” (15.9 mm) GlasRoc®

Sheathing Type X

Steel Corner Bead

Finishing

1-5/8” (41 mm) Steel Stud

Page 21: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

21

Wall Framing

Whererequired,diagonallet-inbracingis

recommended for corners.

•1/2”(12.7mm)GlasRoc Sheathing should

be fastened to wood or steel framing

spaced no more than a maximum of 24”

(600mm)o.c.

•5/8” (15.9mm)GlasRoc Sheathing Type

X should be fastened to wood or steel

framing spaced no more than a maximum

of24”(600mm)o.c.

Ceiling and Soffit Framing

•1/2”(12.7mm)GlasRoc Sheathing should

be fastened to wood or steel framing

spaced no more than a maximum of 16”

(400mm)o.c.forparalleltostudframing

andmaximumof24”(600mm)o.c.for

perpendicular to stud framing.

•5/8”(15.9mm)GlasRoc Sheathing

Type X should be fastened to framing

spaced no more than a maximum of 24”

(600mm)o.c.parallelorperpendicular

to wood or steel framing.

GlasRoc® SheathingFastening Patterns

Framing & Joint Treatments

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Fastening Guidelines

•FastenGlasRoc® Sheathing using only recommended nails or screws.

•AlwaysapplyGlasRoc Sheathing to a flat and even framing surface.

•Drivefastenerstoapointevenwithorslightlybelow[nogreaterthan1/32”(0.8mm)] the surface of GlasRoc Sheathing, without penetrating glass mat.

•Locateperimeterfastenersaminimumof3/8”(10mm)fromedgesandendswithamaximumspacingof8”(200mm)o.c.

• Forshearresistanceapplications, space perimeter fasteners a maximum 4”(100mm)o.c.

•Spacefastenersinthefieldofthe boardamaximumof8”(200mm)o.c.

Limitations

•Donotusestaplesoradhesivestofasten GlasRoc Sheathing to framing members.

•DonotattachGlasRoc Sheathing to framing surfaces with a plane variance greaterthan1/8”(3mm).

•Donotoverdrivefasteners.Becarefulnottobreaktheprotectivesurfacecoating, fracture the underlying core, or penetrate the glass mat.

•GlasRoc Sheathing is not recommended or intended for use as a fastening base.

•Notrecommendedforapplicationswhere continuous exposure temperaturesexceed125°F(52° C).

Fasteningpatternsandotherdetailed

information for the recommended

handling, storage, and application of

gypsum sheathing can be found below

andinthefollowingGAinstallation

specificationguides:GA-253Application

ofGypsumSheathing,GA-254Fire

ResistantGypsumSheathing,GA-216

ApplicationandFinishingofGypsum

Board,GA-226ApplicationofGypsum

BoardtoCurvedSurfaces.

FramingType Fastener Description

1/2”(12.7mm) GlasRoc® Sheathing

5/8”(15.9mm) GlasRoc® Sheathing Type X

WoodHotdip11gage,7/16”(11mm)head,

galvanizednail1-1/2”(38mm) 1-3/4”(44mm)

WoodHotdip12gage,7/16”(11mm)head,

galvanizednail1-1/2”(38mm) 1-3/4”(44mm)

Wood/FurringBuglehead(TypeW),corrosionresistant

screws with coarse threads1-1/4”(32mm)

1-1/4”(32mm)to 1-5/8”(41mm)

Steel/FurringBuglehead(TypeS),corrosionresistant

screws with fine threads1”(25mm) 1-1/4”(32mm)

Light SteelBuglehead(TypeS),corrosionresistant

screws with fine threads1”(25mm) 1-1/4”(32mm)

Light SteelBuglehead(TypeS,TypeS-12)

steel drill screws1-1/4”(32mm)

1-1/4”(32mm)to 1-5/8”(41mm)

Heavy/LightSteelBuglehead(TypeS-12,TypeS)

steel drill tip screws1-1/4”(32mm)

1-1/4”(32mm)to 1-5/8”(41mm)

HeavySteelBuglehead(TypeS-12)drilltip,finethread,rust

resistant gypsum board screws1”(25mm)

1-1/4”(32mm)to 1-5/8”(41mm)

Recommendations for Fasteners Recommended Fastener Length for Board Thickness

Page 22: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

22

What is Covered?

5 Year Limited Warranty

Against Defects

CertainTeed Gypsum (“CertainTeed”)

warrants that its GlasRoc® Sheathing

(“Product”) shall be free from defects in

themanufactureofmaterialsthatmakeit

unsuitable for its intended use, and that

it meets or exceeds the manufacturing

requirements and specifications of

ASTMC1177.

12 Month Warranty Against Exposure

CertainTeed further warrants for up to

twelve (12) months that the Product will

withstand exposure to normal weather

conditions, e.g., UV, rain, wind, ice and

snow, so long as the Product is stored

and installed according to CertainTeed’s

instructions contained in Sections 1.6 and

3.1oftheGlasRocSheathingArchitectural

Specifications.

The5YearLimitedWarrantyandthe12

MonthLimitedWarrantyextendtodealers

who sell this Product, contractors who

install this Product, and the original owner

of the building within the warranty period.

Neitherthe5YearLimitedWarrantynor

the12MonthLimitedWarrantymaybe

assigned or transferred.

How Long Does Coverage Last?

The5YearLimitedWarrantyshall

commence with the date of purchase

by the installing contractor or product

applicator,andcontinueforfive(5)years.

The12MonthLimitedWarrantyshall

commence on the date of installation of

the Product and continue for twelve (12)

months.

What is Not Covered?

CertainTeed shall not be responsible for any

lossresultingfromanyofthefollowing:

•Installationpracticesnotinaccordance

with CertainTeed’s published

recommendation and specifications.

•Improperdesignorinstallationofany

component or portion of the structure.

•DamagetoGlasRocSheathingcausedby

anEIFSsystemnotinstalledinaccordance

with the application instructions of the

EIFSmanufacturer,thearchitectural

specificationsorASTMC1397,“Standard

PracticeforApplicationofClassPB

ExteriorInsulationandFinishSystems”.

•Moistureintrusiondefectsincludinginsect,

fungus, and mold infestation resulting from

the use of other manufacturers’ products.

•Failureoftheownertomaintainthe

building with reasonable care.

•UseofGlasRocSheathingasasubstrate

for any exterior or coatings that are

directly applied to the panel surface

(excluding soffit areas).

•Excludesdamagecausedbyimproper

handling or storage, immersion in water,

floods,fires,hailstorms,earthquakes,

high winds, hurricanes, acts of nature,

fallingobjects,settlingofthebuilding,

movement of the framing members,

failure or distortion in the walls or

foundation of the structure.

•CertainTeedisnotresponsibleforthe

performance of the exterior system

applied over GlasRoc Sheathing including

but not limited to coatings, cladding and

wall coverings.

Effect of State/Provincial Law

THISWARRANTYSTATESTHEFULLEXTENT

OFCERTAINTEED’SRESPONSIBILITY

FORDEFECTSINTHEPRODUCT.

ALLOTHERREPRESENTATIONSAND

WARRANTIESEITHEREXPRESSEDOR

IMPLIED,INCLUDINGWARRANTIESOF

FITNESSFORAPARTICULARPURPOSE

ORMERCHANTABILITY,AREHEREBY

DISCLAIMED.

INNOEVENTSHALLCERTAINTEEDBE

LIABLEFORLOSSOFPROFITSORANY

CONSEQUENTIAL,SPECIAL,INCIDENTAL,

INDIRECTORPUNITIVEDAMAGES,

WHETHERBASEDUPONBREACHOF

WARRANTYNEGLIGENCE,STRICTLIABILITY,

TORT,BREACHOFCONTRACT,ORANY

OTHERLEGALTHEORY.

Some states do not allow the exclusion

or limitation of warranties or do not allow

the exclusion or limitation of incidental or

consequential damages, so the above

disclaimers may not apply to you.

What will CertainTeed do?

CertainTeed will, at its option, provide

replacement Product or a refund up to

double the purchase price.

How To Handle Claims?

Submitallclaimsinwritingwithin30days

of the defect discovery, including a brief

description of the damaged area, with a

copy of the dated sales receipt, invoice and

evidenceofinstallationdate,to:

CertainTeed Gypsum

4300 W. Cypress St., Ste 500

Tampa, FL 33607

USA

Attn: Marketing Manager, Commercial

GlasRoc Sheathing

To effect this sole and exclusive remedy,

the claim must be submitted in writing prior

to the end of the warranty period.

THISSHALLCONSTITUTETHETOTAL

LIABILITYOFCERTAINTEEDANDTHE

EXCLUSIVEREMEDYOFCUSTOMER.

THEREARENOOTHERWARRANTIES,

EXPRESSORIMPLIED,INCLUDINGANY

WARRANTYOFMERCHANTABILITYOR

FITNESSFORAPARTICULARPURPOSE.

LIABILITYISLIMITEDTOTHEABOVEAND

CERTAINTEEDSHALLINNOEVENTBE

LIABLEFORLABORCHARGES,INCLUDING

BUTNOTLIMITEDTO,LABORCHARGES

INCONNECTIONWITHREMOVALOR

REPLACEMENT,NORFORINCIDENTALOR

CONSEQUENTIALDAMAGES.

NorepresentativeofCertainTeedhas

theauthoritytomakeanyrepresentation

or promise with respect to this limited

warranty or otherwise amend, restate, or

supplement this limited warranty.

This warranty applies to GlasRoc Sheathing

soldonorafterJanuary1,2008,intheU.S.

and Canada.

GlasRoc® Sheathing5 Year Limited Warranty

Page 23: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

23

SAFETY:

Formoreinformation,consulttheMaterialSafetyDataSheetbycontactingCertainTeedat1-800-233-8990 oremail:building.solutions@certainteed.com.Foranelectroniccopyofthisspecification,pleasevisit: www.certainteed.com

Section 09253 / 06 16 00 - Sheathing

Part 1-General1.1 RELATED DOCUMENTS

A. Drawingsandgeneralprovisionsofthe Contract, including General and Supplementary

ConditionsandDivision1.SpecificationSections, apply to this Section.

1.2 SUMMARY

A. ThisSectionincludesthefollowing:

1.EmbeddedGlassReinforcedGypsum (EGRG™)SheathingBoard.

2. Sheathingjoint-and-penetrationtreatment.

1.3 DEFINITIONS

A. GypsumBoardConstructionTerminologyStandard:RefertoASTMC11fordefinitionsofterms for gypsum sheathing board construction not defined in this Section or in other referenced standards.

1.4 SUBMITTALS

A. SubmitinaccordancewithSection01330.

B. ProductData:Foreachtypeofproductindicated.

C. InformationalSubmittals:Submitmanufacturer’s instructions, special procedures, and perimeter conditions requiring special attention.

1.5 QUALITY ASSURANCE

A. Fire-Test-ResponseCharacteristics:Forassemblies with fire-resistance ratings, provide materials and construction identical to those of assembliestestedforfireresistanceperASTME119(UL263,CAN/ULC-S101)byatestingandinspecting agency acceptable to authorities having jurisdiction.

1.Fire-ResistanceRatings:IndicatedbydesigndesignationsfromULIandULC“FireResistanceDirectory”andProductsCertifiedfor Canada.

B. SingleSourceResponsibility:Exceptwherespecified otherwise, obtain gypsum board

products,jointtreatment,andaccessoriesfrom single manufacturer or from manufacturers recommended by prime manufacturer of gypsum board products.

1.6 DELIVERY, STORAGE, AND HANDLING

A. Store materials protected against damage from weather, direct sunlight, surface contamination, construction traffic, or other causes.StackCertainTeedGlasRoc® Sheathing flat on leveled supports off the ground, under cover, and fully protected from weather.

1. Store and support CertainTeed GlasRoc Sheathingboardinflatstackstopreventsagging.

2.Protectmaterialstokeepthemdry.

3.Protectgypsumboardpanelstopreventdamage to edges, ends, and surfaces.

1.7 COORDINATION

A. CertainTeedGlasRocSheathing:

1.EGRG™SheathingBoard:Intendedforup to 12 (twelve) months of exposure following installation.

1.8 WARRANTY

A. Manufacturer’sstandardwarrantyforproductexposed to weather without failure, when installed in accordance with manufacturer’s requirements, for period of not less than 12 months.

Part 2-Product

2.1 GYPSUM SHEATHING

A. EmbeddedglassmatgypsumsheathingmeetingtherequirementsofASTMC1177.

1.CertainTeedGypsum,Inc.

a.BasisofDesign:“GlasRocSheathing”withEGRGTM technology

b.Substitutions:SubmitinaccordancewithSection01600.

2. TypeandThickness:TypeX,5/8inch(15.9mm) thickwhereindicatedandasotherwiserequired to meet fire rating for specific element.[1/2inch(12.7mm)elsewhere.]

a.Flamespread:ASTME84:0; CAN/ULC-S102:5

b.Smokedeveloped:ASTME84:0; CAN/ULC-S102:5

3.Size:48bynotlessthan96inches(1219bynotlessthan2438mm);longerlengths as available to reduce number ofjoints.

2.2 SHEATHING JOINT-AND-PENETRATION TREATMENT MATERIALS

A. SiliconeEmulsionSealant:Meeting ASTMC920,TypeS,GradeNS,compatiblewith glass fiber mesh tape and for covering exposed fasteners.

B. Glass-FiberMeshTape:Self-adhering glass-fiber tape, nominal 2 inches (50mm)wide,oftyperecommendedbysheathing and tape manufacturers for use withsiliconeemulsionsealantinsealingjointsin glass-mat gypsum sheathing board and with a history of successful in-service use.

2.3 ACCESSORY MATERIALS

A. Fasteners:Steeldrillscrewsornails,in lengths recommended by sheathing manufacturerforthicknessofsheathingboard to be attached, with organic-polymer or other corrosion- protective coating. Forceiling/soffitapplicationswithDirect-AppliedExteriorFinishSystems(DEFS) andpaintedceilings/soffits,fasteners having a salt spray resistance of more than800hoursaccordingtoASTMB117arerecommended.

1.Forsteelframinglessthan0.0329inch(0.835mm)thick,attachsheathing with steel drill screws complying with ASTMC1002.

2.Forsteelframingfrom0.033to0.112inch(0.84to2.84mm)thick,attachsheathingwithdrillscrewscomplyingwithASTMC954.

3.Forwoodframing,attachwithnailsor screws of type and spacing as recommended by sheathing manufacturer

Part 3-Execution3.1 GYPSUM SHEATHING INSTALLATION

A. ComplywithGA-253,ASTMC1280andmanufacturer’s written instructions.

B. InstallCertainTeedGlasRocSheathingwithpolymercoatedside(logoside)out.Boardsarealso printed with “This side out” on the face side.

C. Cut boards at penetrations, edges, and other obstructionsofwork;fittightlyagainstabuttingconstruction, unless otherwise indicated.

1.Installboardswitha3/8-inch(10mm)setbackwherenon-load-bearingconstructionabuts structural elements.

2.Installboardswitha1/4-inch(6mm)setbackwhere they abut masonry or similar materials that might retain moisture, to prevent wicking.

3.Allownojointsgreaterthan1/8inch(3mm).

D. Coordinate sheathing installation with flashing andjoint-sealantinstallationsothesematerialsare installed in sequence and manner that prevents exterior moisture from passing through completed exterior wall assembly.

E. Applyfastenerssoscrewheadsbeartightlyagainst face of sheathing boards but do not cut into facing.

F. Donotbridgebuildingexpansionjointswithsheathing; cut and space edges to match spacing of structural support elements.

G. HorizontalInstallation:Installsheathingwithlongedgesincontactwithedgesofadjacentboardswithoutforcing.Abutendsofboardsovercentersofstudflanges,andstaggerendjointsofadjacentboardsnotlessthanonestudspacing.Screw-attach boards at perimeter and within field of board to each steel stud.

1.Spacefastenersapproximately8inches (200mm)o.c.(ortighterspacingifrecommended by manufacturer for specific application)andsetbackaminimumof3/8inch(10mm)fromedgesandendsofboards.

3.2 SHEATHING JOINT-AND-PENETRATION TREATMENT

A. Sealsheathingjoints,asrequired,accordingto sheathing manufacturer’s written recommendations.

1.Ifaweathersealisrequiredbeforetheapplication of a water-resistive barrier, apply siliconeemulsionsealantonjointsandtrowelflat.Applysufficientquantityofsealanttocompletelycoverjointsaftertroweling.Sealotherpenetrationsandopenings.Checkwiththe water-resistive barrier manufacturer for installation instructions prior to the application of sealant.

2.Whenthecodesallowtheapplicationasanalternate to separate water-resistive barrier -Applyglass-fibermeshtapetofiberglassreinforcedgypsumsheathingboardjoints,and apply and trowel silicone emulsion sealant to embed sealant in entire face of tape.Applysealanttoexposedfastenerswitha trowel so fasteners are completely covered. Seal other penetrations and openings.

B. Water-ResistiveBarrier:

1. Consult building code authority having jurisdictionforrequirementsregardingwater-resistive barrier installation, if necessary.

3.3 Ceilings and Soffits

A. Finishingisaccomplishedwithoneofthefollowingmethods:

1.Direct-AppliedExteriorFinishSystem(DEFS)isappliedperthemanufacturer’sspecifications.

2.Applynominal2inch(50mm)wideglassmeshdrywalltapeand90minute,setting-typejointcompoundontheboardjoints. Skimcoattheentiresurfacewithasetting-type compound, prime and paint with good quality exterior grade primer and paint per the manufacturer’s recommendations.

GlasRoc® SheathingArchitectural Specifications

GypsumBoard&FinishingProductsfromCertainTeed•CallTollFree800-233-8990•www.glasroc.com•www.certainteed.com

Page 24: 2015 CertainTeed...CertainTeed Est. 1665 2015 ® CertainTeed respects the environment through the responsible development of sustainable building products and systems. By utilizing

©11-2003 CertainTeed Gypsum. Rev 05-2012

Printed in U.S.A. on recycled paper. CTG-2355/3M

Confidence worth building on.

Confidence worth building on

Con�denceAssuranceTime-testedLong-term

GlasRoc®Sheathingfeaturingpatented*Embedded

Glass Reinforced GypsumTM technology is strong,

yetflexibleenoughtobendtocurvedsurfaceslike

thoseatBonnetCreek.

Great Design Deserves Great Protection.

Project (pictured above): BonnetCreek,Orlando,FL

Architect: Smallwood,Reynolds,Stewart& Associates,Atlanta,GA

General Contractor: HuntConstructionGroup,Orlando,FL

TM®CertainTeedandthetagline“Qualitymadecertain.Satisfactionguaranteed.”aretrademarksofCertainTeedCorporation.Allothertrademarksare the property of CertainTeed’s affiliates and related companies.

NOTICE:Theinformationinthisdocumentissubjecttochangewithoutnotice.CertainTeedassumesnoresponsibilityforanyerrorsthatmayinadvertently appear in this document.

*CoveredbyU.S.PatentNo.6,524,679;6,878,321;6,866,492,andotherpatentspending.

©4-2015CertainTeedGypsum. PrintedintheU.S.A.onrecycledpaper.CTG-2362/3M