30-INCH DOWNDRAFT SPECIFICATIONS SPECIFICATIONS Overall Width 30" (762 mm) Overall Height (above countertop) 9 1 /16" (230 mm) Overall Depth 2 3 /8" (60 mm) CFM Recommendations 1 cfm per 100 Btu/hr (.03 Kwh) Internal Blower (Model DD30I) 500 cfm Remote Blower (Model DD30R) 600, 900 or 1200 cfm Transition 3 1/4” x 14” to 10-inch round (Model DD30R) Included (Model DD30I) Duct Size 3 1 /4" (83 mm) x 10" (254 mm) (Model DD30I) 3 1 /4" (83 mm) x 14" (356 mm) (Model DD30R) Discharge Adjustable Electrical Supply Requirements 110/120 V AC, 60 Hz, 15 amp (min) dedicated circuit Conduit 6' (1.8 m) power cord / 3-prong grounded plug Shipping Weight 80 lbs (36.3 kg) Special Note Must also order DD30CONTROL/S (802510), DD30CONTROL/B (801624) or DD30CONTROL/P (801623). Specifications are subject to change without notice. OVERALL DIMENSIONS Dimensions may vary by + _ 1/8" (3 mm). Dimensions in parentheses are in millimeters. 2 3 /8" (60 mm) 30" (762 mm) 9 1 /16" (230 mm) 26 1 /4" (667 mm) 1 1 /2" (38 mm) DEPTH OF DOWNDRAFT CHIMNEY BLOWER OPTIONS 500 cfm Internal Blower 900 cfm Remote Blower 801641 1200 cfm Remote Blower 801642 1500 cfm Remote Blower 804701 TOP COVER AND CONTROL BEZEL Classic Stainless Steel Platinum Stainless Steel Carbon Stainless Steel

30-INCH DOWNDRAFT SPECIFICATIONS

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 30-INCH DOWNDRAFT SPECIFICATIONS

30- INCH DOWNDRAFTSPECIF ICATIONS

S P E C I F I C A T I O N S

Overall Width 30" (762 mm)

Overall Height (above countertop) 91/16" (230 mm)

Overall Depth 23/8" (60 mm)

CFM Recommendations 1 cfm per 100 Btu/hr (.03 Kwh)

Internal Blower (Model DD30I) 500 cfm

Remote Blower (Model DD30R) 600, 900 or 1200 cfm

Transition 3 1/4” x 14” to 10-inch round (Model DD30R)Included (Model DD30I)

Duct Size 31/4" (83 mm) x 10" (254 mm) (Model DD30I)31/4" (83 mm) x 14" (356 mm) (Model DD30R)

Discharge Adjustable

Electrical Supply Requirements 110/120 V AC, 60 Hz,15 amp (min) dedicated circuit

Conduit 6' (1.8 m) power cord / 3-prong grounded plug

Shipping Weight 80 lbs (36.3 kg)

Special Note Must also order DD30CONTROL/S(802510), DD30CONTROL/B (801624)

or DD30CONTROL/P (801623).

Specifications are subject to change without notice.

O V E R A L L D I M E N S I O N S

Dimensions may vary by +_ 1/8" (3 mm).

Dimensions in parentheses are in millimeters.

23/8"(60 mm)

30"(762 mm)

91/16"(230 mm) 261/4"

(667 mm)

11/2" (38 mm)DEPTH OF

DOWNDRAFT CHIMNEY

B L O W E R O P T I O N S

500 cfm Internal Blower

900 cfm Remote Blower 801641

1200 cfm Remote Blower 801642

1500 cfm Remote Blower 804701

T O P C O V E R A N D C O N T R O L B E Z E L

Classic Stainless Steel

Platinum Stainless Steel

Carbon Stainless Steel

Page 2: 30-INCH DOWNDRAFT SPECIFICATIONS

2

21/8" (54)

191/4" (489)COOKTOP CUT-OUT

DEPTH

267/8" (683)

36"(914)

23/8" (67)

251/8" MIN (638)OF FLAT COUNTERTOP*

.344"

295/16"(745)

COUNTERTOPTO BOTTOM OF

AIR BOX

18"(457)

35/8"(92)

31/4"(83)

5"(127)

711/16"(197)

5/8"(16)

21/2" MIN(64)

WITH NO RAISED LIP*

*AREAS OF POTENTIAL INTERFERENCE

21/2" MIN(64)

23/4" (70)

COOKTOP CUT-OUTWIDTH

24" MIN (610)CABINET DEPTH

13/4" MIN (45)BACK EDGE

OF COOKTOPTO INSIDE OF

CABINET BACK*

71/8"(181)

251/8" MIN(638) FLAT

COUNTERTOPSPACE

191/4"(489)

NOTE: Dimensions in parentheses are in millimeters.

C O U N T E R T O P C U T- O U T D I M E N S I O N S

Dimensions may vary by +_ 1/8" (3 mm).

30- INCH DOWNDRAFTSPECIF ICATIONS

Page 3: 30-INCH DOWNDRAFT SPECIFICATIONS

D O W N D R A F T V E N T I L A T I O N S Y S T E M S

IMPORTANT NOTE: The downdraft ventilation systemsare recommended for use with Wolf electric, gas andintegrated cooktops, excluding the steamer and fryercooktops. For Wolf dual fuel ranges, gas ranges andrangetops, use a Pro Series ventilation hood.

Wolf Downdraft systems come in 30" (762 mm) and 36"(914 mm) widths. The top cover and user interface areavailable in the classic stainless steel finish, and the pre-mium finishes of platinum and carbon stainless steel.

P L A N N I N G A N DD E S I G N I N F O R M A T I O N

The downdraft ventilation system should be at least aswide as the cooking surface you are designing into thehome.

The 30" (762 mm) downdraft will fit most 30" (762 mm)wide cabinets and the 36" (914 mm) downdraft will fit inmost 36" (914 mm) wide cabinets. Cabinet backs mayneed to be removed. It is recommended that oversizedcabinets be used for easier installation.

IMPORTANT NOTE: To incorporate a downdraft systemand a Wolf cooktop, you must allow for a minimum 25-1/8" (638 mm) flat counter space from front to back. Acountertop with a raised lip and/or backsplash may notallow enough space for proper installation. 2-3/8" (60mm) of flat countertop is required behind the cooktopand 1-3/4" (44 mm) is necessary between the back edgeof the cooktop and inside of cabinet back. Also, the cabi-net back may need to be removed.

When installing cooktop service connections, you MUSTuse adjacent base cabinets outlined in the cooktop speci-fications.

Except for Models DD30I and DD36I, downdrafts areshipped without the blower assembly. The blower orventilator will vary in size and is dictated by the cookingsurface and the distance to the exterior of the home. Theblower assemblies are quite varied, and depending onthe amount of air you want to move and the length ofthe duct run, you have many options.

You also need to consider if you are going to use theseassemblies as internal blowers or mount them externally.

Refer to the Cooktop Ventilation Recommendations chartsat the end of this section or contact your Wolf dealer foradditional information.

IMPORTANT NOTE: If the 30" (762 mm) downdraft isbeing installed in a 30" (762 mm) wide cabinet, or the36" (914 mm) downdraft in a 36" (914 mm) wide cabi-net, the outlet cannot be located on the back wall of thecabinet. The outlet may be placed in adjacent cabinetry.Refer to the illustration, in this section for placement ofelectrical.

You must follow all National Electrical Code regulations.In addition, be aware of local codes and ordinanceswhen installing your service.

Wolf downdraft systems have an adjustable dischargethat will allow you to negotiate ducting around floorjoists and other obstacles. Refer to the illustration forinstallation options.

IMPORTANT NOTE: This appliance must be used with aWolf approved top cover and user interface.

The remote mounted user interface is sold as a salesaccessory.

You must plan the installation of the user interface to bewithin 10' (3.0 m) of the downdraft assembly and a min-imum of 4" (102 mm) from the outer edge of cooktopelement or burner. You will be required to drill threeholes and connect the two units by the provided wire.

30- INCH DOWNDRAFTSPECIF ICATIONS

Page 4: 30-INCH DOWNDRAFT SPECIFICATIONS

30- INCH DOWNDRAFT VENTILATIONREQUIREMENTS / RECOMMENDATIONS

1

Number Description Model

CTBLOWER-90REM Remote Blower 900 CFM 30-inch or 36-inch Downdrafts

CTBLOWER-120REM Remote Blower 1200 CFM 30-inch or 36-inch Downdrafts

CTBLOWER-150REM Remote Blower 1500 CFM 30-inch or 36-inch Downdrafts

TRANS-10-8 3 1 / 4 " x 10" to 8" Round Transition 30-inch or 36-inch Downdrafts

TRANS-14-8 3 1 / 4 " x 14" to 8" Round Transition 30-inch or 36-inch Downdrafts

TRANS-14-10 3 1 / 4 " x 14" to 10" Round Transition 30-inch or 36-inch Downdrafts

TRANS-10-10 3 1 / 4 " x 10" to 10" Round Transition 30-inch or 36-inch Downdrafts

TRANS-8-10 8" Round to 10" Round Transition 30-inch or 36-inch Downdrafts

Number Description Finish

DD30CONTROL/S 30-inch Downdraft Control Module with Trim Classic

DD30CONTROL/P 30-inch Downdraft Control Module with Trim Platinum

DD30CONTROL/B 30-inch Downdraft Control Module with Trim Carbon

B L O W E R O P T I O N S

C O N T R O L M O D U L E S

Downdrafts CT15E CT15G CT30E CT30G CT36E CT36G IG15** IM15** IS15** IF15**

DD30I 215* 215* 500 500

DD30R 215* 215* 900 900

* Use these requirements to determine total CFM when installing multiple cooking products.

** Downdrafts are not recommended for use with IF15 or IS15.

NOTE: CFM requirements are averages based on total BTU output. Wolf recommends 1 CFM per 100 BTU. Additional CFM

required for long duct runs.

M I N I M U M C F M R E Q U I R E M E N T S

B L O W E R C R O S S - R E F E R E N C E

Downdrafts Blower Number Transition Duct Size

DD30I or DD36I Internal 500 CFM Included Not Required 3 1 / 4 " x 10"

DD30R or DD36R Remote 900 CFM CTBLOWER-90REM TRANS-14-10 3 1 / 4 " x 14"

DD30R or DD36R Remote 1200 CFM CTBLOWER-120REM TRANS-14-10 3 1 / 4 " x 14"

DD30R or DD36R Remote 1500 CFM CTBLOWER-150REM TRANS-14-10 3 1 / 4 " x 14"

NOTE: Adjustable discharge.

NOTE: Blower configurations are for reference only. Please refer to minimum CFM recommendations for your specific

cooking product. Always consult a qualified HVAC Engineer for specific applications.