24
AMA COMPUTER COLLEGE MAKATI CITY CASE STUDY PRESENTATION As partial fulfillment of the subject CCIT04A Network Fundamentals 3 rd tri 2009-2010 Prof. Maricel Y. Villalino Instructor

30797449 10 Floor Office Building Network Design

Embed Size (px)

Citation preview

Page 1: 30797449 10 Floor Office Building Network Design

AMA COMPUTER COLLEGE

MAKATI CITY

CASE STUDY PRESENTATION

As partial fulfillment of the subject

CCIT04A

Network Fundamentals

3rd tri 2009-2010

Prof. Maricel Y. Villalino

Instructor

Page 2: 30797449 10 Floor Office Building Network Design

GRADING SHEET

DATE : April 12, 2009

TIME : 10 :00 – 11 :00 AM

ROOM : CISCO LAB

PANELIST : __________________________

__________________________

GROUP LEADER : Faye, Shella

MEMBERS : Dollentas, Ernesto III

Reyes, Lomer

Tuico, Odessa

Antolin, Paulo

NAME OF STUDENT INDIVIDUAL GRADEand their ASSIGNED TASK

FAYE, Shella Riser diagram & Quotation of the whole design

DOLLENTAS, Ernesto III Floor plan, layout and vlsm

REYES, Lomer Printout of online prices and compilation of brochures

TUICO, Odessa Documentation (Introduction, Acknowledgement, Purpose of the Study etc.)

Page 3: 30797449 10 Floor Office Building Network Design

TABLE OF CONTENTS

Introduction …..................…............................................................................................. 4

Acknowledgement …........…........................................................................................... 5

Purpose of the study …....................................................................................................... 6

Given Requirements …....................................................................................................... 7

Riser Diagram …................................................................................................................. 8

Floor Layout ….................................................................................................................. 9

Legend …............................................................................................................................ 19

Quotation of the whole design …........................................................................................ 20

IP addressing …...................................................................................................................23

Page 4: 30797449 10 Floor Office Building Network Design

INTRODUCTION

Designing a network can be a challenging task. To design a reliable, scalable networks,

networks designers must realize that each of the three major components of a network has a

distinct design requirements. Attempting to optimize networks that feature thousands of nodes can

pose even more complex problems.

Despite improvements in equipment performance and media capabilities, network design

is becoming more difficult. The trend toward increasingly complex environments involving

multiple media, multiple protocols, and interconnection to networks outside any single

organization’s dominion of control. Carefully designing networks can reduce the hardships

associated with growth as networking environment evolves.

Page 5: 30797449 10 Floor Office Building Network Design

ACKNOWLEDGEMENT

We would like to thank God for giving us everything we need. And for each and every

one of us in this group who gave time and effort to make the completion of this case study

possible.

We are deeply grateful to our professor, Ms. Maricel Y. Villalino, who gave us the basic

knowledge, tools, and motivation in pursuing this project although it is a challenging course it is a

worthy learning process.

Special thanks should be given to our fellow student who helped us in many ways. Finally, words

alone cannot express the thanks we owe to our friends and families, for their encouragement and

assistance.

Page 6: 30797449 10 Floor Office Building Network Design

PURPOSE OF THE STUDY

The purpose of this case study is to apply the knowledge of our group gained in our Cisco

Networking class.

From this point on, we’ll have to effectively design a 10th floor building with biometrics

system that would serve as attendance recorder and that would automatically generate payroll. We

also need to remember that the hosts can access the Internet for some reasons. And some

departments can access the server. Server must have back-up. Wifi connection must be available

at the employee’s lounge. End devices will be distributed based on department’s need. The range

must be indicated as well as the size of the lounge room. Specifications of the PC requirements

must be highly considered due to the specified task for each department. Number of host was also

given by our professor and need to be met by our designed network.

Page 7: 30797449 10 Floor Office Building Network Design

GIVEN REQUIREMENTS

Design a 10-floor building with biometrics system that would serve as attendance recorder and that would automatically generate payroll. Put in mind that not all hosts can access the Internet for some reasons. And some departments can access the server. Server must have back-up. Wifi connection must be available at the employee’s lounge. End devices will be distributed based on department’s need. The range must be indicated as well as the size of the lounge room. Specifications of the PC requirements must be highly considered due to the specified task for each department. The following are the no. of hosts required:

Reception - 2

IT - 5

Training Room - 100

Examination Room - 50

Marketing Dept. - 50

Accounting Dept. - 8

Audit Dept. - 5

Customer Assistance - 200

Research Dept - 25

Audio-Visual Dept - 50

Graphics & Design Dept - 50

Quality Control Dept. - 50

Software Developing Lab. - 150

Conference Room - 2 (holds 50 people)

Conference Room - 2 (holds 25 people)

Staff Office - 50

Presidents’ office - 2

Vice-Pres. office - 2

TOTAL 803

Page 8: 30797449 10 Floor Office Building Network Design

RISER DIAGRAM

Page 9: 30797449 10 Floor Office Building Network Design

FLOOR LAYOUT

1st Floor

Page 10: 30797449 10 Floor Office Building Network Design

2nd Floor

Page 11: 30797449 10 Floor Office Building Network Design

3rd Floor

Page 12: 30797449 10 Floor Office Building Network Design

4th Floor

Page 13: 30797449 10 Floor Office Building Network Design

5th Floor

Page 14: 30797449 10 Floor Office Building Network Design

6th Floor

Page 15: 30797449 10 Floor Office Building Network Design

7th Floor

Page 16: 30797449 10 Floor Office Building Network Design

8th floor

Page 17: 30797449 10 Floor Office Building Network Design

9th floor

Page 18: 30797449 10 Floor Office Building Network Design

10th Floor

Page 19: 30797449 10 Floor Office Building Network Design

LEGEND

Computer

Printer

Server

Switch

UTP cable

Page 20: 30797449 10 Floor Office Building Network Design

QUOTE OF THE WHOLE DESIGN

The building is a 10-floor building. Each floor consists of one or more rooms. All

computers in one room are connected to a switch. All switches are connected to one main switch

that is located in the IT Department in 5th Floor. That switch is connected to 2 routers and to the

internet.

The Server that can access all the networks in the building is located in the IT department

in the 5th floor. The switch in the IT room is connected to 3 servers. 1 will be the main server, and

the other is the back up server.

Not all host can access the internet. The training room, Examination room and the two

conference room cannot access the internet. The server is blocking the IP address of the hosts in

those rooms.

There is a biometrics system that would serve as attendance recorder and that would

automatically generate payroll. It is located in the 1st or ground floor in the reception area. The

biometric system and the computers in the reception are connected to the same switch.

There is also a lounge room with wifi connection in the 1st floor. The range is able to reach

all the location in the lounge room. The wireless device is being connected to the switch in the IT

department.

Page 21: 30797449 10 Floor Office Building Network Design

Floor Assignment:

1st floor - There will be a receptionist desk near the entrance. It's for the inquiry need of the guest

that will visit the building. Biometric system and the lounge room with wifi connection

is located in this room also. Biometrics

2nd floor - Training room and examination room is located here. The two rooms have no access to

the internet. Because there is no need for the computer that is used for exam and

training to use the internet.

3rd floor - Customer assistance is located in this floor. This is where the employee will assist

customer and answering their concern about the company.

4th floor - Marketing aepartment, audit department and accounting department is located in this

floor. These department will need to communicate with each other often, that's why they

are located in the same floor

Page 22: 30797449 10 Floor Office Building Network Design

5th floor - The IT room is located here. The IT department is responsible for handling passwords,

order processing, product and service questions, pricing information, system transfers,

and general inquiries.

6th floor - Audio visual department and graphic & design department is located here. These

department will need to communicate with each other often, that's why they are located

in the same floor

7th floor - Software enveloping laboratory is located in this floor. The location is near the audio

visual, graphic and design, and IT department because it has some similar function so

they can communicate easily.

8th floor - Research department and quality control department is located in this floor. The quality

control department has no internet connection because this is the place where the

employee will check their product and productivity. There is no need for the internet.

9th floor - Staff office is located here, where the staff will settle and work on their task.

Page 23: 30797449 10 Floor Office Building Network Design

10th floor - Two conference rooms, presidents and vice presidents office is located in this floor.

The conference rooms doesn't have access to the internet. Because this is the place to

handle meeting or seminar which not requiring the internet.

VLSM Table

Page 24: 30797449 10 Floor Office Building Network Design

NetworkName

Hosts Required

Slash/Prefix

SubnetMask

NetworkAddress

HostAddresses

BroadcastAddress

CustomerAssistance 200 /24 255.255.255.0 192.168.0.0 192.168.0.1 –

192.168.0.254 192.168.0.255

SoftwareDevelopingLaboratory

150 /24 255.255.255.0 192.168.1.0 192.168.1.1 –192.168.1.254 192.168.1.255

Training Rm. 100 /25 255.255.255.128 192.168.2.0 192.168.2.1 – 192.168.2.126 192.168.2.127

Examination Rm. 50 /26 255.255.255.192 192.168.2.128 192.168.2.129 –

192.168.2.190 192.168.2.191

MarketingDept. 50 /26 255.255.255.192 192.168.2.192 192.168.2.193 –

192.168.2.254 192.168.2.255

Audio-Visual Dept. 50 /26 255.255.255.192 192.168.3.0 192.168.3.1 –

192.168.3.62 192.168.3.63

Graphics & Design Dept 50 /26 255.255.255.192 192.168.3.64 192.168.3.65 –

192.168.3.126 192.168.3.127

QualityControl 50 /26 255.255.255.192 192.168.3.128 192.168.3.129 –

192.168.3.190 192.168.3.191

StaffOffice 50 /26 255.255.255.192 192.168.3.192 192.168.3.193 –

192.168.3.254 192.168.3.255

ResearchDept. 25 /27 255.255.255.224 192.168.4.0 192.168.4.1 –

192.168.4.30 192.168.4.31

AccountingDept. 8 /28 255.255.255.240 192.168.4.32 192.168.4.33 –

192.168.4.46 192.168.4.47

IT Dept. 5 /29 255.255.255.248 192.168.4.48 192.168.4.49 –192.168.4.54 192.168.4.55

Audit Dept. 5 /29 255.255.255.248 192.168.4.56 192.168.4.57 –192.168.4.62 192.168.4.63

Reception 2 /30 255.255.255.252 192.168.4.64 192.168.4.65 –192.168.4.66 192.168.4.67

President’s Office 2 /30 255.255.255.252 192.168.4.68 192.168.4.69 –

192.168.4.70 192.168.4.71

Vice-President’s Office

2 /30 255.255.255.252 192.168.4.72 192.168.4.73 –192.168.4.74 192.168.4.75