Upload
duongdiep
View
232
Download
0
Embed Size (px)
Citation preview
© CEA. All rights reserved
Yann LAMY - Progam line manager 3D section
Gilles SIMON – Head of 3D packaging laboratory
3D silicon for smart biomedical devices
© CEA. All rights reserved
Healthcare and
medicine
Population aging –
elderly people wellness
Monitoring and
diagnosis
Advanced and secure
surgery
Overcoming handicaps
and disabilities
Heathcare: new societal challenges
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 2
New advanced medical devices need
© CEA. All rights reserved
Which devices for which medicine?
| 3 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
External and/or disposable devices
Temporarly implanted devices
Long-term implantable devices
Intervention catheters / endoscopes / drug delivery systems…
Smart pills / intraocular pressure sensors…
CRT (Pacemaker), Vagusnerve stimulation…
© CEA. All rights reserved
Implantable devices for new medicine
| 4
Hearth stimulation
Deep Brain Stimulation
Retina implants
Cochlear implant
Brain activity sensing
Electrophysilogy monitoring
Vagus nerve stimulation
Bladder stimulation
Localized drug delivery
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Many diverse and specific challenges
© CEA. All rights reserved
Medical devices communication
Wireless monitoring Wearable monitoring devices
Example: capture the patient gesture and analyze it through
a dedicated software.
Implantable or embedded antenna in devices
New Infrastructure for medical networking
| 5 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Source: IEEE biomedecine, Corchado et al. 2010
Wearable full body sensors, source: MOVEA
Antenna radiation in hearing aid device, L. HUITEMA et al. CEA LETI 2012
© CEA. All rights reserved
Requests from clinicians: Efficacy
Localized and live monitoring
Fast data analysis
Reliability
Price
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 6
Applications challenge the technology
… with translate in complex technological needs
Small form factor
NO leads
Easily placed and targeted
Autonomous and communicating
Fabricated in facilities with high degree of reproducibility and reliability
© CEA. All rights reserved
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 7
3D technology assets for biomedical More Moore vs More-than-Moore
Source: ITRS, 2010
High level heterogeneous
integration
3D silicon integration opportunities
- Low form factor - High reliability - Low Power - Existing supply chains
Source: OPEN3D, LETI
© CEA. All rights reserved
3D Si integration assets and specs
1. Sensing & actuation
2. Computing & communicating
3. Power management
4. Biopackaging
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 8
Source: John Lau, ITRI, InterPACK 2011
Put all functionalities on a Si interposer with:
Silicon Wafer Level Packaging (WLP)
Heterogeneous materials integration
Multiple dies sourcing
Use of z-direction for ultra miniaturization & density
Keys parameters to
address
Yole report, 2010
Through-Silicon-Vias
© CEA. All rights reserved
Medical image sensing
Ultra miniaturized camera for endoscopy with TSVs
| 9 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Source: I-Micronews May 2011
- Through-Silicon-Vias (TSV) packaging - 180nm TowerJazz CMOS image sensor - 0.99mm diameter endoscop - Camera image sensor size: 0.66mmx0.66 mm - 45k pixels
Ultra small camera will enable new medical diagnostic and therapeutic markets. Disposable devices, 4M units annually increasing to 7M units in 2015
Medigus and Towerjazz, May 2011 CMOS sensor
TSV
Glass
© CEA. All rights reserved
Biomedical sensing
9mmHg <P< 21 mmHg
Psystolique < 15 cmHg. Pdiastolique < 9cmHg
Intra-brain
pressure
2mmHg <P< 20 mmHg
Blood
pressure
Ocular pressure
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Bladder
pressure
Different applications, environment, duration and range One technology
0mmHg <P< 15 mmHg
Representative case: pressure sensing
© CEA. All rights reserved
Sensing: pressure monitoring
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 11
3D packaging allows a compact integration of a MEMS & RF antenna
« In 2010, 60 millions worldwide suffers from Glaucoma come from high intra ocular
pressure ». Quigley et al, 2006
Source: D. Ha et al. Purdue university IMS 2010 Integration in mouse’s eye
3D IC and MEMS stacking
© CEA. All rights reserved
Sensing: acceleration monitoring
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 12
Source: A. Rippart INEMI, May 2011
3D MEMS wafer level packaging on IC wafer
CRT ex: pacemaker
© CEA. All rights reserved
Computing and communicating
IC dies integration in biomedical Advanced node emergence (<65nm)
Small I/O pads
Multiple dies sourcing
Low CTE mismatch
Ultra low-loss antenna
ICs dies in contact with blood
| 13 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
IC RF
interposer
3D Silicon interposer can overcome IC integration limitations
CRT ex: pacemaker
Cascaded & communicating hemodynamic
IC & sensors for diagnosis and treatment
Source: A. Rippart INEMI, May 2011
TSV
antenna
© CEA. All rights reserved
| 14 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Smart miniature low-power wireless microsystem for Body Area Network
3D integration: a key technology for mixing functionalities for ultra miniaturization and low energy
Computing and communicating
Source:
© CEA. All rights reserved
550nF/mm2 demonstrated using
high-k dielectrics in 3D
Power management
| 15 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Efficient energy management: use the 3D in silicon
Source: Roozeboom, Lamy et al. , NXP, Power SOC 2008
DRIE etched pores DRIE etched pillars 3D integrated capacitors
or
Source: website
Press release – 10th of April 2012
&
PICS: Passives Integrated Connective Substrate
© CEA. All rights reserved
Power management
| 16 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
~1.2mm ~900um
RF Die PICS
3D Si capacitors integration in implantable module
SiP Package for pacemaker: •RF Transceiver •XO •SAW Filter •400MHz & 2.4GHz Matching network with integrated coils •Decoupling capacitances
3D capacitors allow the RF module realization 40% smaller than the PCB realization.
- 40 % area decrease - 25 % height decrease
14mm
8m
m
Source: Vivarès, Voiron, Lamy, et al. LETI –IPDIA-SORIN -Minapad 2011
Collaboration between:
6.4
5m
m
11.2mm
Si interposer
© CEA. All rights reserved
3 key factors: Biocompatibiliy
“The ability of a material to perform with an appropriate host response in a specific application” (Buddy Ratner in Biomaterials Science)
Hermiticity: prevent fluids leakage
- Toxic susbtances from device (ex: cu) Body
- Corrosive body fluids (ex: blood) Device
Shape
- Soft rounded shape to prevent Foreign Body Reaction (FBR)
3 categories:
| 17 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Biopackaging
Exposition Long term Middle term Shot term
Implantation definitive temporary Externale/ disposable
Examples pacemaker Intraocular pressure sensor endoscop
Biocompatibility requirements on implants (ISO 10993).
Biocompatibility of silicon is still subject to controversy
Potentially high volume, low cost opportunities for 3D electronic
devices
© CEA. All rights reserved
Wafer-level 3D chip biopackaging:
| 18 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI
Biopackaging
Biocompatibility is a surface-mediated property 3D surface passivation
Wafer-level processing allows cost effective, miniaturized and biocompatible packaging
Electrode deposition: Gold, Platinium
3D inorganic passivation: SiOx, SiNy…
CMOS standard passivation and aluminium pads
Wafer level 3D shaping:top and bottom
3D polymer passivation: PDMS, Parylen…
Parylene-C
SiO2
Au USGS / TEOS/SIN
AlCu SiO2 th
© CEA. All rights reserved
Opportunities: Disposable devices
Ultra miniaturization
Mixing of many functionalities & technologies
Process standardization
Reliability from microelectronics Fabs
3D silicon biomedical devices
Coming challenges: Reach critical mass in volume production
New supply chains to set
Reliable in-vitro and in-vivo tests
Reduce costs
| 19 EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 19
US implantable devices market has a 7,7% market groth rate, and will exceed $50 Billion by 2015
LETI BioBOX concept
© CEA. All rights reserved
Thank you
EPoSS 2012 | 3D silicon for smart biomedical devices| YannLAMY - LETI | 20