3
ALIO’s passion has built a reputation for unmatched quality and performance with our nano-precision motion systems. ALIO’s world leading performance is backed by our NIST referenced ML10 laser interferometer system from Renishaw. ALIO True Nano™ means Proof. 4-Axis Protein Crystallography System ALIO’s integrated 4-axis system was specifically developed to help front line scientists to conduct industry leading x-ray research in protein crystallography. True Nano™ Eight of the world's largest pharmaceutical companies have banded together to run a beam-line at Argonne's Advanced Photon Source (APS) dedicated to determining protein structures and developing new drugs. The discoveries that they and other biomedical researchers at the APS make today provide the foundation for life-saving drugs that doctors will prescribe tomorrow. The X-rays produced by the APS synchrotron and shot through IMCA's beam-lines allow the researchers at these companies to scan thousands of proteins and inhibitor molecules for the next wonder drug. (source: http://www.anl.gov/Media_Center/ArgonneNow/Winter_2009/pharmaceuticals.html) ALIO True Nano™ NIST Traceable Proof v3 16-October 2009 Options: Sample Holder Granite Base for Improved Vibration Isolation Radial: < +/- 1um T.I.R. Axial: < +/- 100nm T.I.R. System Run-Out at XY Integrated 4-Axis Controller EPICS Compatible 110V or 220V Compatible 20nm to 50nm Step Size ± 200nm to ± 300mm Repeatability 4.88nm Resolution 10mm Travel Mount to the Face of the Rotary AI-D4-2500E AI-D2-1200E XY 0.3 arc-sec/sec Speed, min ± 0.2 arc-sec Repeatability 0.02 arc-sec Resolution 360° Continuous Travel R Z Mounted on Z AI-TM-183R 20nm to 50nm Step Size < ± 100nm Repeatability 4.88nm 100mm Resolution Travel Bottom Axis AI-LM-20000 ALIO True Nano™ Specifications

4-Axis Protein Crystallography System - ALIO Industries · 2015. 7. 27. · 001 1 b nbrown 12/3/2009 a 195.00 mm [7.677 in] 122.50 mm [4.823 in] rotational axis centerline q xy axis

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 4-Axis Protein Crystallography System - ALIO Industries · 2015. 7. 27. · 001 1 b nbrown 12/3/2009 a 195.00 mm [7.677 in] 122.50 mm [4.823 in] rotational axis centerline q xy axis

ALIO’s passion has built a reputation for unmatched quality and performance with our nano-precision motion systems. ALIO’s world leading performance is backed by our NIST referenced ML10 laser interferometer system from Renishaw.

ALIO True Nano™ means Proof.

4-Axis Protein Crystallography SystemALIO’s integrated 4-axis system was specifically developed to help front line

scientists to conduct industry leading x-ray research in protein crystallography.

True Nano™

Eight of the world's largest pharmaceutical companies have banded together to run a beam-line at Argonne's Advanced Photon Source (APS) dedicated to determining protein structures and developing new drugs. The discoveries that they and other biomedical researchers at the APS make today provide the foundation for life-saving drugs that doctors will prescribe tomorrow.

The X-rays produced by the APS synchrotron and shot through IMCA's beam-lines allow the researchers at these companies to scan thousands of proteins and inhibitor molecules for the next wonder drug.

(source: http://www.anl.gov/Media_Center/ArgonneNow/Winter_2009/pharmaceuticals.html)

ALIO True Nano™NIST Traceable Proof

v316-October 2009

Options:

Sample Holder

Granite Base for Improved Vibration Isolation

Radial: < +/- 1um T.I.R.Axial: < +/- 100nm T.I.R.

System Run-Out at XY

Integrated 4-Axis ControllerEPICS Compatible110V or 220V Compatible

20nm to 50nmStep Size

± 200nm to ± 300mmRepeatability

4.88nmResolution

10mmTravel

Mount to the Face of the Rotary

AI-D4-2500EAI-D2-1200E

XY

0.3 arc-sec/secSpeed, min

± 0.2 arc-secRepeatability

0.02 arc-secResolution

360° ContinuousTravel

R

Z

Mounted on ZAI-TM-183R

20nm to 50nmStep Size

< ± 100nmRepeatability

4.88nm

100mm

Resolution

Travel

Bottom AxisAI-LM-20000

ALIO True Nano™ Specifications

Page 2: 4-Axis Protein Crystallography System - ALIO Industries · 2015. 7. 27. · 001 1 b nbrown 12/3/2009 a 195.00 mm [7.677 in] 122.50 mm [4.823 in] rotational axis centerline q xy axis

ALIO True Nano™

4-Axis Protein Crystallography System

True Nano™

v316-October 2009

Total Radial Run-Out Total Axial Run-Out

Testing Procedure:

Radial Run-out: All tests were performed using 8 continuous revolutions of the AI-TM-125R-AB stage with XY stage mounted on the rotary face. Rotational velocity was 1 deg/sec and the data collection was 10 Hz.

Axial Run-out: All tests were performed using 8 continuous revolutions of the AI-TM-125R-AB stage with XY stage mounted on the rotary face. Rotational velocity was 90 deg/sec and the data collection was 500 Hz.

The stage was mounted on a granite table in the fully assembled state and placed in the ALIO environmental test room. Prior to testing the stage was soaked in the test environment for 24+ hours and cycled for 2 hours to ensure thermal stability.

Page 3: 4-Axis Protein Crystallography System - ALIO Industries · 2015. 7. 27. · 001 1 b nbrown 12/3/2009 a 195.00 mm [7.677 in] 122.50 mm [4.823 in] rotational axis centerline q xy axis

1 1

2 2

3 3

4 4

AA

BB

TITL

E

SIZ

ED

WG

NO

RE

V

SC

ALE

SH

EE

TO

F

DR

AW

N

CH

EC

KE

D

MA

TER

IAL

Tole

ranc

es:

S

urfa

ce R

ough

ness

:

x.x `

.05

in [1

.3 m

m]

x.xx

`.0

1 in

[0.2

5 m

m]

x.xx

x `

.005

in [0

.13

mm

]

R

MS

MA

X.

Ang

les `

0.5~

1191

9 W

I-70

FR

ON

TAG

E R

OAD

NO

RTH

, UN

IT 1

19, W

HEA

T R

IDG

E, C

O 8

0033

US

A(T

el) 3

03.3

39.7

500

- SA

LES

@A

LIO

IND

US

TRIE

S.C

OM

- W

WW

.ALI

OIN

DU

STR

IES.

CO

M

ALI

O IN

DU

STR

IES

PR

OP

RIE

TAR

Y IN

FOR

MA

TIO

N

ALI

O S

TD T

EM

PLA

TE -

RE

V 0

06FI

NIS

HS

EE

NO

TES

4 A

XIS

PR

OTE

IN

CR

YS

TALL

OG

RA

PH

Y S

YS

TEM

0010

-022

181

1 001

B

NB

RO

WN

12/3

/200

9

A

122.

50 m

m [4

.823

in]

195.

00 m

m [7

.677

in]

RO

TATI

ON

AL

AX

IS

CE

NTE

RLI

NE

q

XY A

XIS

AS

SE

MB

LY

(MO

UN

TED

TO

RO

TAR

Y F

AC

EU

SED

FO

R S

AM

PLE

CE

NTE

RIN

G)

360

DEG

RE

E C

ON

TIN

UO

US

RO

TAR

Y(W

ITH

INTE

GR

ATE

D S

LIP

RIN

G)

Z LI

NE

AR

AX

IS14

5.00

mm

[5.7

09 in

]

30.0

0 m

m [1

.181

in]

20.0

0 m

m [0

.787

in]

4X M

2x0.

4 - 6

H x

2.5

mm

SAM

PLE

MO

UN

TIN

G T

APS

387.

50 m

m [1

5.25

6 in

]

254.

00 m

m [1

0.00

0 in

]

50.8

0 m

m [2

.000

in]

127.

00 m

m [5

.000

in]

25.4

0 m

m [1

.000

in]

4X n

7.14

mm

TH

RU

v n

11.1

3 m

m x

20.

96 m

mA

SS

EM

BLY

MO

UN

TIN

G H

OLE

SA

CC

ESS

FR

OM

TO

P S

IDE

170.

00 m

m [6

.693

in]

n5.

0 m

m (H

9) x

5.0

mm

SLI

P F

IT F

OR

M5

DO

WE

L P

IN(C

ENTE

RE

D O

N Z

AX

IS S

TAG

E)

340.

00 m

m [1

3.38

6 in

](Z

AX

IS S

TAG

E LE

NG

TH)

72.5

0 m

m [2

.854

in]

20.0

0 m

m [0

.787

in]

SA

MPL

E M

OU

NTI

NG

S

UR

FAC

E

CAB

LE E

XIT

72.5

0 m

m [2

.854

in]

STA

ND

AR

D F

EATU

RES

SY

STE

M S

PE

CIF

ICA

TIO

NS

:

RA

DIA

L R

UN

OU

T: <

+/-

1 um

TIR

A

XIA

L R

UN

OU

T: <

+/-

100

nm T

IRR

OTA

RY

AX

IS -

AI-T

M-8

3R-A

B-L

T

RA

VE

L: 3

60 D

EG

RE

ES

CO

NTI

NU

OU

S

RE

PE

ATA

BIL

ITY

: < 0

.5 A

RC

-SE

C

MIN

IMU

M V

ELO

CIT

Y: 0

.008

RP

MZ

AX

IS -

AI-L

M-2

0000

-T10

0

TR

AV

EL:

100

mm

R

EP

EA

TAB

ILIT

Y: <

200

nm

S

TEP

SIZ

E: 2

0 - 5

0 nm

X &

Y -

AI-D

4-25

00E

& A

I-D2-

1200

E:

T

RA

VE

L: 1

0 m

m

RE

PE

ATA

BIL

ITY

: < 3

50 n

m

STE

P S

IZE

: 20

- 50

nm

EN

VIR

ON

ME

NT:

STA

ND

ARD

, CLE

AN

RO

OM

, TE

MP

ERA

TUR

E: 0

to 3

5 D

EG

CH

UM

IDIT

Y: 1

0% to

80%

NO

N-C

ON

DE

NS

ING

AS

SE

MB

LY M

AS

S: 2

1 kg

INC

LUD

ES A

CC

ESSO

RIE

SIN

TEG

RA

TED

4 A

XIS

CO

NTR

OLL

ER

E

LEC

TRO

NIC

S C

HA

SS

IS F

OR

EA

SY

INTE

GR

ATI

ON

TOO

L S

AM

PLE

HO

LDE

R (O

PTI

ON

AL)

CU

STO

M D

ESI

GN

S F

OR

OE

M IN

TEG

RA

TIO

N A

VA

ILA

BLE