9
UNIVERSIDAD NACIONAL DE INGENIERIA FACULTAD DE INGENIERIA CIVIL EC231-H INGENIERIA Alumno: MISAICO SAIRITUPAC KEVIN 20012!3A T"#$#%o: CUARTA ENTREGA 201&-II

4 ENTREGA ANTISISMICA

Embed Size (px)

DESCRIPTION

ingenieria antisismica

Citation preview

UNIVERSIDAD NACIONAL DE INGENIERIA

UNIVERSIDAD NACIONAL DE INGENIERAFACULTAD DE INGENIERA CIVIL

UNIVERSIDAD NACIONAL DE INGENIERIAFACULTAD DE INGENIERIA CIVIL

ANALISIS DINAMICO MODAL ESPECTRALINFORMACION:Zona 3 ICA: Z=0.4Factor de Uso: U=1Suelo tipo S1: S=1, Tp(S)=0.4Coeficiente de Reduccin: DUAL R=7PERIODO FUNDAMENTAL DE VIBRACION:T=Ct = 60sistema dualHn = 17 mT=0.283333 s

FACTOR DE AMPLIFICACION SISMICA:C = 2.5 ()

GRAFICO DEL ESPECTRO SEGN LA NORMATCSa

0.002.501.40

0.052.501.40

0.102.501.40

0.152.501.40

0.202.501.40

0.252.501.40

0.302.501.40

0.352.501.40

0.402.501.40

0.452.221.24

0.502.001.12

0.551.821.02

0.601.670.93

0.651.540.86

0.701.430.80

0.751.330.75

0.801.250.70

0.851.180.66

0.901.110.62

0.951.050.59

1.001.000.56

1.050.950.53

1.100.910.51

1.150.870.49

1.200.830.47

1.250.800.45

1.300.770.43

1.350.740.41

1.400.710.40

1.450.690.39

1.500.670.37

1.550.650.36

1.600.630.35

1.650.610.34

1.700.590.33

1.750.570.32

1.800.560.31

1.850.540.30

1.900.530.29

1.950.510.29

2.000.500.28

2.050.490.27

2.100.480.27

GRAFICO:

PROCEDIMIENTO UTILIZANDO PROGRAMA ETABSSe procede a introducir el espectro de la norma

Luego creamos un nuevo caso de carga en ambas direcciones

Modificamos la direccin del sismo

RESULTADOSVERIFICACION DE CORTANTE EN LA BASE DINAMICO CON EL ESTATICO:DIRECCION X

StoryLoad Case/ComboLocationPVXVY

tonftonftonf

Story1SX2Bottom0-811.93710

Story1SXdinamico MaxBottom0541.566214.072

% V dinmico con respecto V esttico67%< 80%ES NECESARIO ESCALAR EL CORTANTE DINAMICO

V dinmico min649.55ton

factor1.25

DIRECCION Y

StoryLoad Case/ComboLocationPVXVY

tonftonftonf

Story1SY2Bottom00-811.9371

Story1Sydinamico MaxBottom014.072588.0095

% V dinmico con respecto V esttico72%< 80%ES NECESARIO ESCALAR EL CORTANTE DINAMICO

V dinmico min649.55ton

factor1.25

TABLA DE FUERZAS CORTANTES E FUERZAS INERCIALES ESCALADOS:DIRECCION X

StoryLoad Case/ComboLocationVXVYVx escalado(Ton)FX(ton)

tonftonf

Story6SXdinamico MaxBottom129.6253.3591162.03162.03

Story5SXdinamico MaxBottom257.06326.6425321.33159.30

Story4SXdinamico MaxBottom361.86339.3703452.33131.00

Story3SXdinamico MaxBottom445.690111.5506557.11104.78

Story2SXdinamico MaxBottom508.442813.1927635.5578.44

Story1SXdinamico MaxBottom541.566214.072676.9641.40

DIRECCION Y

StoryLoad Case/ComboLocationVXVYVy escalado (Ton)FY (ton)

tonftonf

Story6Sydinamico MaxBottom3.3224137.499171.87171.87

Story5Sydinamico MaxBottom6.6426276.1256345.16173.28

Story4Sydinamico MaxBottom9.3992390.8177488.52143.37

Story3Sydinamico MaxBottom11.594482.7203603.40114.88

Story2Sydinamico MaxBottom13.2273551.5816689.4886.08

Story1Sydinamico MaxBottom14.072588.0095735.0145.53

VERIFICACION DE DESPLAZAMIENTOS:DIRECCION X

StoryLoad Case/ComboLabelItemDrift 0.75R ADM.

Story6SXdinamico Max30Max Drift X0.0003710.001947750.007

Story5SXdinamico Max30Max Drift X0.0005250.002756250.007

Story4SXdinamico Max30Max Drift X0.0006750.003543750.007

Story3SXdinamico Max30Max Drift X0.0007930.004163250.007

Story2SXdinamico Max30Max Drift X0.000850.00446250.007

Story1SXdinamico Max51Max Drift X0.0005670.002976750.007

Observamos que se cumplen todos niveles el desplazamiento

DIRECCION Y

StoryLoad Case/ComboLabelItemDrift0.75R ADM.

Story6Sydinamico Max49Max Drift Y0.0003680.0019320.007

Story5Sydinamico Max49Max Drift Y0.0005150.002703750.007

Story4Sydinamico Max49Max Drift Y0.0006540.00343350.007

Story3Sydinamico Max49Max Drift Y0.0007640.0040110.007

Story2Sydinamico Max49Max Drift Y0.0008290.004352250.007

Story1Sydinamico Max49Max Drift Y0.0005820.00305550.007

Observamos que cumplen todos los niveles en desplazamientoJUNTA DE SEPARACION SISMICA:Como se observa del plano de planta en la direccin x se encuentra el lmite de propiedad De la tabla de desplazamientos mximos en la direccin x escogemos el mayor y luego lo multiplicamos por la altura del nivel:0.00446253 100 = 1.34 cm S = 21.34/3 = 0.89 cm S/2 = (3+0.004 (1700-500))/2 = 3.9 cm S/2 = 1.5 cmEscogemos el mayor de todos: S = 3.9 cm 1

EC-231 INGENIERIA ANTISIMICA Pgina 7