4

54 JACKIE - Ares Ill · Jackie - Transparent Glass - 40° - Direct 230V 842800 PAR 16 35W/230V GZ10 Lamp max size: Ø50 mm H.55 mm Optional LED bulb DR PAR 7,5W/230V GZ10 Lamp max

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 54 JACKIE - Ares Ill · Jackie - Transparent Glass - 40° - Direct 230V 842800 PAR 16 35W/230V GZ10 Lamp max size: Ø50 mm H.55 mm Optional LED bulb DR PAR 7,5W/230V GZ10 Lamp max
Page 2: 54 JACKIE - Ares Ill · Jackie - Transparent Glass - 40° - Direct 230V 842800 PAR 16 35W/230V GZ10 Lamp max size: Ø50 mm H.55 mm Optional LED bulb DR PAR 7,5W/230V GZ10 Lamp max

525Jackie

JACKIE54

LED VERSION: Class A/A+/A++Luminaire supplied with integrated LED modules that cannot be replaced

A++

A+

AHALOGEN VERSION: Class BQR-CBC51/GU5,3

B

HALOGEN VERSION: Class DQRPARCBC51/GZ10

D

EU Regulation 874/2012 - Illumination equipment energy classes

LED VERSION:Class A/A+/A++Luminaire supplied with integrated LED modules that cannot be replaced

.1 White .6 Grey .3 Anthracite .18 Deep Brown.4 Black

The fitting is equipped with 1 cable input

Protection againstimpact.IK 08 - 5,00 joule

Wall fitting

Remote power supply required

• Luminaire for installation on wall – surface mounted.• Configuration: die-cast aluminium structure, EN AB-47100

alloy (low copper content). Glass diffuser: transparent.• Double layer coating for high resistance to corrosion:

the aluminium components are painted with a double coat using powders that are compliant with QUALICOAT standards: a first layer of epoxy powder (with excellent chemical and mechanical resistance) and a second finishing layer of polyester powder (resistant to UV rays and atmospheric agents). The entire painting process of the aluminium fitting starts from components that have been sandblasted in advance to make the surface more porous and increase the adherence of the paint. Ares effects alkaline and acid washing to clean the surfaces completely, then rinses with demineralised water to remove any residue particles, subsequently a chemical conversion treatment is done to protect against rusting.

• Protection rating: IP54• In compliance with EN 60598-1 standards• Class of insulation: mains: I; low voltage: III• Installation: wiring through a rubber cable holder

(5mm<Ø<10mm cables). Outdoor use requires suitable flexible cables assuring the watertightness of the cable holder.

• During the installation and the maintenance of the fixtures it is important to be careful and avoid damages on the paint coating. Damages on the coating exposed to outdoor conditions or water, could cause corrosion.Chemical substances affect the anticorrosion covering protection.

HALOGEN VERSION:Class D QPARCBC51/GZ10

HALOGEN VERSION:Class B QR.CBC51/GU5,3

Page 3: 54 JACKIE - Ares Ill · Jackie - Transparent Glass - 40° - Direct 230V 842800 PAR 16 35W/230V GZ10 Lamp max size: Ø50 mm H.55 mm Optional LED bulb DR PAR 7,5W/230V GZ10 Lamp max

526 Jackie

C0 / C180 C90 / C270

cd / 1000 lm

60˚

30˚

90˚

2000

22899 5744 2525 1416 9

= 12.0˚+ 12.0˚ = 15.0˚+ 15.0˚

Max Medm1.00

2.003.004.005.00

395

lux lux

beam 40˚

C0 / C180 C90 / C270

cd / 1000 lm

60˚

30˚

90˚

1600

290126 7356 3231 1820 12

= 21.0˚+ 21.0˚ = 21.0˚+ 21.0˚

Max Medm1.00

2.003.004.005.00

503

lux lux

40°

708

0

95 54

54

708

0

95

8412801 White 3000K lm LED 688 ≠ lm OUTPUT 327

Jackie - Transparent Glass

Light Source: CoB LED / 5W / Total power 6W / CRI>80 / 220÷230V / LED module set up to work directly connected to the mains

Jackie - Transparent Glass - 40° - Direct 230V

842800 PAR 16 35W/230V GZ10Lamp max size: Ø50 mm H.55 mm

Optional LED bulb DR PAR 7,5W/230V GZ10Lamp max size: Ø50 mm H.55 mm

Page 4: 54 JACKIE - Ares Ill · Jackie - Transparent Glass - 40° - Direct 230V 842800 PAR 16 35W/230V GZ10 Lamp max size: Ø50 mm H.55 mm Optional LED bulb DR PAR 7,5W/230V GZ10 Lamp max

527Jackie

65

5030

acc. code

prod. code 237

842800

8412801 •

Accessories: Jackie

237SPD: (SURGE PROTECTION DEVICE) 275Vac MAXIMUM DISCHARGE CURRENT 10KA (8/20μs) MAXIMUM OPERATING CURRENT 5ASUITABLE FOR SERIES CONNEC-TION - IP66