750W DIRTY WATERSUBMERSIBLE PUMPMODEL: PDW-750

INSTRUCTION MANUAL

0212

WARNING! Read all safety warnings and all instructions. Failure to followthe warnings and instructions may result in electric shock, fire and/or seriousinjury. Save all warnings and instructions for future reference.

Page 2: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

INTRODUCTION

Congratulations on purchasing the Commercial Electric 750W Dirty WaterSubmersible Pump. We aim to provide quality products at an affordable price.Before using, it is most important that you read and follow the instructions inthis manual, even if you feel you are quite familiar with this type of product.

This product has been designed for numerous water transfer applications.These include draining flooded laundries, bathrooms, basements or garages,emptying rainwater tanks, pools and spas, emptying garden ponds andtransferring water for domestic irrigation. This product is not suitable for usewith drinking (potable) water.

SPECIFICATIONSInput Voltage: 230-240V ~ 50HzInput Power: 750WMax. Immersion Depth: 7mMax. Head: 7.5mMax. Flow Rate: 16,500 litres/hourMax. Particle Size: 35mmMin. Water Depth: 70mmMax. Water Temp: 35°CHose Sizes: 25, 32mm inside diameterTap Adaptor Size: 25mm (1'') Power Cable Length: 10mIP Rating: IPX8 Weight: 5.4kg

KNOW YOUR PRODUCT

9

2

6

8

1

1. Handle2. Pump Housing3. Universal Adaptor4. L-Shape Connector5. Suction Base6. Float Switch7. Vent Valve8. Float Switch Adjustor9. Float Switch Cable10. Power Cable

3

4

1

10

5

7

Page 3: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

2

TABLE OF CONTENTS

INTRODUCTION………………………………………………….………………

SPECIFICATIONS …………………………….……………………..…………...

KNOW YOUR PRODUCT ……………………………………………………….

ELECTRICAL SAFETY……………………………………………………………

GENERAL SAFETY INSTRUCTIONS…………………………………………..

ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPS…………..…………..

SUGGESTED APPLICATIONS………………….………………………………

PACK CONTENTS…………………………………………………………………

FITTINGS AND TOOLS REQUIRED FOR INSTALLATION……………………

PREPARATION…………………………………………………………………….

SET-UP & INSTALLATION……………………………………………………….

OPERATION……………………………………………………………………….

HINTS WHEN USING THE PUMP………………………………………………

MAINTENANCE ………………………………………..…………………………

SPARE PARTS…………………………………………………………………….

TROUBLESHOOTING………………………………………………..…………..

DESCRIPTION OF SYMBOLS……………………………………….………….

WARRANTY……………………………………………………………………….

1

1

1

3

3

5

6

6

6

7

9

10

11

11

11

12

14

15

Page 4: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

ELECTRICAL SAFETY

WARNING! When using mains-powered equipment, basic safety precautions, including thefollowing, should always be followed to reduce risk of fire, electric shock, personal injury andmaterial damage.

Read and understand the manual prior to operating this tool.Save these instructions and other documents supplied with this tool for future reference.The electric motor has been designed for 230V and 240V only. Always check that the power supplycorresponds to the voltage on the rating plate.

Note: The supply of 230V and 240V on Commercial Electric tools are interchangeable for Australiaand New Zealand.

This tool is earthed in accordance with AS/NZS 60335-2-41

If the power outlet is external, ensure that it is weather proof. If the supply cord is damaged, it mustbe replaced by an electrician or a power tool repairer to avoid a hazard.

The water pump has a built-in thermal protection overload switch. The water pump stops if anoverload occurs. The motor restarts automatically after it has cooled down.

Using an extension leadAlways use an approved extension lead suitable for the power input of this product. Before use,inspect the extension lead for signs of damage, wear and ageing. Replace the extension lead ifdamaged or defective.

When using an extension lead on a reel, always unwind the lead completely. Use of an extensionlead not suitable for the power input of this product or which is damaged or defective may result in arisk of fire and electric shock.

GENERAL SAFETY INSTRUCTIONSSAVE THESE INSTRUCTIONS

1) WORK AREAa) Keep work area clean and well lit. Cluttered and dark areas invite accidents.b) Do not operate pumps in explosive atmospheres, such as in the presence of flammable

liquids, gases, or dust. Pumps create sparks which may ignite the dust or fumes.c) Keep children and bystanders away while operating a pump. Distractions can cause you to lose

control.

2) ELECTRICAL SAFETYa) Pump plugs must match the outlet. Never modify the plug in any way. Do not use any

adapter plugs with earthed (grounded) pumps. Unmodified plugs and matching outlets willreduce risk of electric shock.

b) Avoid body contact with earthed or grounded surfaces such as pipes, radiators, ranges andrefrigerators. There is an increased risk of electric shock if your body is earthed or grounded.

3

Page 5: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

4

GENERAL SAFETY INSTRUCTIONS (cont.)c) Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the pump.

Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cordsincrease the risk of electric shock.

e) When operating a pump outdoors, use an extension cord suitable for outdoor use. Use of acord suitable for outdoor use reduces the risk of electric shock.

3) PERSONAL SAFETYa) Stay alert, watch what you are doing and use common sense when operating a pump. Do not

use a pump while you are tired or under the influence of drugs, alcohol or medication. Amoment of inattention while operating pumps may result in serious personal injury.

b) Avoid accidental starting. Ensure the switch is in the off position before plugging in. Carryingpumps with your finger on the switch or plugging in pumps that have the switch on invites accidents.

c) Remove any adjusting key or wrench before turning the pump on. A wrench or a key leftattached to a rotating part of the pump may result in personal injury.

d) Dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and glovesaway from moving parts. Loose clothes, jewellery or long hair can be caught in moving parts.

4) PUMP USE AND CAREa) Disconnect the plug from the power source before making any adjustments, changing

accessories, or storing pumps. Such preventive safety measures reduce the risk of starting thepump accidentally.

b) Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts andany other condition that may affect the pumps operation. If damaged, have the pumprepaired before use. Many accidents are caused by poorly maintained pumps.

c) Use the pump, accessories and tool bits etc., in accordance with these instructions and inthe manner intended for the particular type of pump, taking into account the workingconditions and the work to be performed. Use of the pump for operations different from intendedcould result in a hazardous situation.

5) SERVICEa) Have your pump serviced by a qualified repair person using only identical replacement parts.

This will ensure that the safety of the pump is maintained.b) If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or

similarly qualified persons in order to avoid a hazard.

Page 6: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

5

ADDITIONAL SAFETY INSTRUCTIONS FOR PUMPSCAUTION: If operating a pump in a swimming pool or spa, use a residual current device (RCD)protected supply.

WARNING! This product is intended for pumping water in a Home Domestic application. Donot use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than waterwill damage the water pump and/or create a fire hazard.

WARNING! This product is not suitable for use with drinking (potable) water.

This appliance is not intended for use by person (including children) with reduced physical,sensory or mental capabilities, or lack of experience and knowledge, unless they have beengiven supervision or instruction concerning use of the appliance by a person responsible fortheir safety.Children should be supervised to ensure that they do not play with the appliance.• Ensure the water pump is disconnected from mains power when installing.• Do not install or operate the water pump in an explosive environment or near flammable material.• Do not operate the water pump without liquid.• Do not run the water pump dry.

WARNING! The water pump together with associated pipework operate under pressure. Donot disconnect water pump or pipework until internal pressure has been released. Failure todo this could result in personal injury and damage to property.

• Avoid inserting hands into the inlets/outlets of the water pump while it is connected to mains power.• Before using the water pump, always inspect it visually. Do not use the pump if it is cracked

and/or damaged. If the water pump is damaged, contact Commercial Electric customer service.• The water pump has a built-in thermal protection overload switch. The water pump stops if an

overload occurs. The motor restarts automatically after it has cooled down.The pump must not be used when people are in the water.Never work or perform maintenance on the pump without first making sure it has been disconnectedfrom the mains power.Pollution of the liquid could occur due to leakage of lubricants.

IMPORTANT: Avoid inserting hands into the mouth of the pump if it is connected to the mains.The electrical connection must always be made in a dry area. Make sure that electrical connectionsare protected from inundations.Protect the plug and the power cable from heat, oil or sharp edges.If damaged, The power cable must be replaced by a qualified electrician.

!!

!!

!!

Page 7: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

6

SUGGESTED APPLICATIONSDraining flooded laundries, bathrooms, basements or garages.

Emptying rainwater tanks, pools and spas. Transferring water for domestic irrigation.

Emptying garden ponds and water features.

PACK CONTENTS1 x Dirty water submersible pump (PDW-750) 1 x Universal adaptor1 x L-shape connector (2 O-rings fitted) 1 x Instruction manual

FITTINGS AND TOOLS REQUIRED FOR INSTALLATION

Included1 x L-shape connector (2 O-rings fitted) 1 x Universal adaptor

Not IncludedSuitable hose/tube/piping Tap adaptor (optional)Hose clamp (optional) Hack saw (optional)Rope (optional) Non-return valve (optional)

Page 8: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

!!

!!

7

PREPARATION

WARNING! This product is intended for pumping water in a home domestic application. Donot use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than waterwill damage the water pump and/or create a fire hazard.

WARNING! Disconnect the plug from the mains power prior to making any adjustments orinstallation.

Your pump requires no assembly before use other than the connection of a suitable outlet hose (not supplied).• After removing the pump from its carton, check that the pump has not been damaged.• Unpack the contents.NOTE: Use the handle (1) when lifting or moving the pump. Never hang thepump by the power cable (10) (Fig. 1).

The pump can be used in either permanent applications or temporaryapplications. In either application, the installation guidelines must befollowed.

• Ensure the distance from thelowest to the highest point thatyou wish to distribute the waterdoes not exceed 7.5m (Fig. 2).

• Ensure that the pump is notsubmerged deeper than 7m(Fig. 2).

• Ensure that the container islarge enough (40 x 40 x 50cm)to allow the float switch (6) tomove freely and functioneffectively (Fig. 2).

• Ensure the pump is placed on a flat and level surface andthere are no obstructions to thesuction base (5).

Float

Discharge point

Max. head: 7.5m

Max. immersion depth: 7m

Water level

Pump

Water container

Power cable: 10mFig. 2

Fig. 1

Page 9: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

8

PREPARATION (cont.)Preparing the Universal AdaptorThe universal adaptor (3) is designed to fit various sizes of pipes and fittings. Prepare the universal adaptor (3) as required for the accessory, seeoptions A, B & C below. The universal adaptor (3) allows a range ofdifferent diameter hose/tube to be fitted (Fig. 3).

A) To fit a 25mm (1’’) tap adaptor (temporary application only) Cut the universal adaptor (3) using a hack saw (notincluded) (Fig. 4). It is now ready to be fitted with a 25mm (1’’) tap adaptor and flexible tubing (not included)(Fig. 5).

B) To fit a 25mm (1’’) rigid pipe or flexible tubing(temporary or permanent application) No cutting of the universal adaptor (3) is required (Fig. 6).It is now ready to be fitted with a 25mm (1’’) rigid pipe orflexible tubing (not included) (Fig. 7).

C) To fit a 32mm (11/4’’) rigid pipe or flexible tubing(temporary or permanent application) Cut the universal adaptor (3) using a hack saw (notincluded) (Fig. 8). It is now ready to be fitted with a 32mm(11/4’’) rigid pipe or flexible tubing (not included) (Fig. 9).

NOTE: To use the pump in permanent installations with rigid pipes, install a non-return valve to avoidthe fluid being re-circulated once the pump has stopped. NOTE: After temporary applications, the pump should be cleaned with clean water after each use,see "Maintenance" section for more information.

Fig. 3

25mm hose/tube

25mm tap adaptor

32mm hose/tube

Fig. 4 Fig. 5

Fig. 6 Fig. 7

Fig. 8 Fig. 9

Page 10: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

9

SET-UP & INSTALLATION1. Screw the L-shape connector (4) into the pump housing (2) by rotating

in a clockwise direction (Fig. 10).NOTE: Make sure the L-shape connector (4) is firmly tightened so that the O-ring is compressed between the pump housing (2) and the L-shapeconnector (4). This ensures no leakage will occur at this point.

2. Screw the prepared universal adaptor (3) clockwise onto the L-shapeconnector (4) (hose/tube/tap adaptor should not be connected at thisstage) (Fig. 11).

NOTE: Make sure the universal adaptor (3) is firmly tightened so that the O-ring of the L shaped connector (4) is compressed between the universaladaptor (3) and the L shaped connector (4). This ensures no water or airleakage will occur at this point.

3. Securely attach the hose/tube/tap adaptor (not included) to the universaladaptor (3) (Fig. 12) (see the section "Preparing the Universal Adaptor").

NOTE: Due to the high water pressure generated by the pump it isrecommended to use a hose clamp (not included) when fitting a flexiblehose or tube (available from your local Bunnings Warehouse). This securesthe hose or tube and further prevents it from becoming removed from theuniversal adaptor (3) during operation (Fig. 13).

NOTE: Before submerging the pump in water, unwrap the power cable (10)and ensure the plug is clear of any damp locations.

4. To immerse the pump in deep water, use a rope (not included) andsecure it to the handle (1) (Fig. 14). Set the pump in the desired positionwithin the work area/tank.

NOTE: The vent valve (7) is used to allow air to escape from the pump bodywhen submerging the pump so no priming is required.

Fig. 11

Fig. 12

Fig. 14

Fig. 13

Fig. 10

Page 11: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

SET-UP & INSTALLATION (cont.)NOTE: The pump has a pre-set float switch (6). To change the setting,reduce or increase the length of the float switch cable (9) by inserting it in thefloat switch adjuster (8) (Fig. 15 & 16).When the float switch cable (9) is able to move freely (float switch adjustor (8) isnot in use), the pump will function down to a water depth of 150mm. Restrictingthe length of the float switch cable (9) using the float switch adjustor (8), resultsin the pump ceasing operation at higher water depths.The length of the float switch cable (9) between the float switch adjustor (8)and the float switch (6) must be at least 100mm in order for the float switch(6) to activate and de-activate.

5. When the float switch (6) is adjusted as you require, use the rope (notincluded) to immerse the pump back into the body of water.

OPERATION1. When the float switch (6) is 30° higher than horizontal (start up level) or

above the handle (1), the pump will turn ‘on’ and operate (water depth of530mm) (Fig. 17).

ATTENTION: The pump runs as soon as the float switch (6) reaches thestart-up level.

2. When the float switch (6) is 30° lower than the horizontal or below thehandle (1), the pump will turn ‘off’ and will not operate (water depth ofapproximately 150mm) (Fig. 18). You can alternatively, manually turn thepump off at the mains power.

ATTENTION: If you wish to use the pump down to the minimum water depth of70mm, the float switch (6) will need to be operated manually. The pump can bemanually turned “on” by lifting the float switch (6) to the required level.CAUTION: You must observe the pump at all times when operating manually.NOTE: If you manually turn the pump off, be aware of the location of yourhose or tube (not included). If it is at a lower point than the pump, the water will continue to ‘siphon’out, unless a non-return valve (not included) is used in the hose or tube and turned off.

Turning On and Off1. Insert the plug into the mains power socket (Fig. 19). Avoid using

extension cords as this can lead to a voltage drop which may causepower loss and overheating.

2. Switch on the mains power to commence operation.3. To cease operation, turn off the mains power. The pump will also stop

operation automatically once the float switch (6) reaches the minimumwater depth (150mm).

Fig. 19

Fig. 17

Fig. 18

10

Fig. 15

Fig. 16

Page 12: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

HINTS WHEN USING THE PUMP• The maximum pumping rate only occurs when using the largest diameter hose or tube possible, if

smaller diameter hoses or tubes are used, the rate will reduce relative to the size of thehose/tube. Try to use discharge pipes which have a larger diameter than the discharge outlet.

• Running the pump with no water flowing through leads to increased wear and is notrecommended. The pump must be immediately unplugged as soon as water stops flowingthrough.

The pump will automatically switch off in the event of overheating due to the built-in thermaloverload protector. After cooling down, the motor automatically switches on again.

• When disconnecting the pump from the mains power supply, do not pull by the power cable (10).Using 3 fingers around the 3 pin power plug, gently pull and disconnect from the mains power.

MAINTENANCEIn ordinary conditions, the pump does not require any maintenance. Make sure the pump is disconnected from electric power supply before performing maintenance procedures.

Cleaning the Pump HousingUse a moist cloth to wipe down the pump housing (2). Allow to dry thoroughly before storing in a drylocation that is protected from bad weather conditions.

Cleaning the Suction BaseGently hose down with low pressured water. Allow to dry thoroughly before storing.

Power CableFor all submersible pumps, a H07RN-F cable is required to be fitted. Contact Commercial Electriccustomer service for replacement cable.

SPARE PARTSLimited spare parts are available subject to availability. Please contact your local Bunnings SpecialOrders Desk to order the required spare parts.Most common spare parts listed belowSpare Part Part No.O-ring SPPDW750-19O-ring SPPDW750-23Impellor SPPDW750-25O-ring SPPDW750-31L-Shape connector SPPDW750-34Pack of 2 O-rings for L-Shape connector SPPDW750-35Universal adaptor SPPDW750-36

11

Page 13: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

12

TROUBLESHOOTING

Problem Possible Cause Solution

The pump does notstart, or pump water

Pump is not connected to themains power supply

Check that the pump is connected tothe mains power supply

Float switch has not beenactivated, water level too low

Manually raise the position of thefloat switch

Incorrect assembly leads to airand water leakage in thedischarge lines

Ensure the discharge lines are thecorrect length and all assemblyinstructions are adhered to

The thermal overload protectionis activated

Wait for the motor to cool and it willautomatically start operation

The motor is damaged Contact Commercial Electric customerservice

The pump does notsupply water whenthe motor is running

The suction base isobstructed/blocked

Clean the suction base of anyforeign matter and debris

Air lock in the hose/tube and/orpump (air bubbles)

Perform several start-ups in order toremove all the air or lift and tilt thepump slightly while the pump is running

Discharge hose/tube(not included) is kinked ordamaged

Un-kink the discharge hose/tube. Orreplace hose/tube

The pump flow rateis reduced

The suction base is partiallyobstructed/blocked

Clean the suction base of anyforeign matter and debris

The hose/tube is obstructed Remove the obstructions

Pump will not turnoff, even though thewater level is low

The float switch is stuck in the“on” position

Ensure that the float switch is free tooperate normally. ContactCommercial Electric customerservice if the problem still occurs

Hose/tube does notstay on theuniversal adaptorwhen water istravelling through

The hose/tube is slightly widerthan the dimension of theuniversal adaptor

An adhesive can be used insidethehose/tube to prevent this or teflontape can be fixed around theuniversal adaptor or a hose clampcan be used (Fig. 13)

Air leak in the suction line orjoints

Check the suction line connectionsfor air leaks and tighten or fix wherefound

Page 14: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

13

TROUBLESHOOTING (cont.)

Problem Possible Cause Solution

The pump operatesintermittently

The suction base isobstructed/blocked

Clean the suction base of anyforeign matter and debris

Incorrect voltage is being used Ensure the pump is connected into230-240V power supply

The fluid contains particlesthicker than 35mm

Ensure the pump is not being usedwith particles thicker than 35mm.

The motor is faulty or damaged Contact Commercial Electriccustomer service

The temperature of the fluid istoo high

Ensure that maximum permissiblewater temperature (35°C) is notexceeded

Water level is below 70mm Ensure the water level is above 70mm

Page 15: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

DESCRIPTION OF SYMBOLS

V Volts Hz Hertz

~ Alternating current W Watts

/min Revolutions or reciprocation per minute

Hp Horse power ˚C Degrees Celsius

p/hr Per hour kPa Pressure rating (kilopascals)

bar Pressure rating L Litres

F Insulation class PVC Polyvinyl chloride

no No load speed

Regulator compliance mark

Warning Read instruction manual

IPX8 Ingress protection from water

CARING FOR THE ENVIRONMENT

Power tools that are no longer usable should not be disposed of with householdwaste but in an environmentally friendly way. Please recycle where facilities exist.Check with your local council authority for recycling advice.

Recycling packaging reduces the need for landfill and raw materials. Reuse ofrecycled material decreases pollution in the environment. Please recyclepackaging where facilities exist. Check with your local council authority forrecycling advice.

14

Page 16: 750W DIRTY WATER SUBMERSIBLE PUMPcdn1.blocksassets.com/.../PDW-750-Manual-Ed14.pdf750W DIRTY WATER SUBMERSIBLE PUMP MODEL: PDW-750 INSTRUCTION MANUAL 0212 WARNING! Read all safety

2 YEAR REPLACEMENT WARRANTY

Your product is guaranteed for a period of 24 months from the original date of purchase and is intended for DIY (Do It Yourself) use only. If a product is defective it will be replaced in accordance with the terms of this warranty. Warranty excludes consumable parts, for example: o-rings, bearing, seals, gaskets, universal adaptors, L-shaped connectors.

WARNING

The following actions will result in the warranty being void.

Professional, Industrial or high frequency use.If the tool has been operated on a supply voltage other than that specified on the tool.If the tool shows signs of damage or defects caused by or resulting from abuse, accidents or alterations.Failure to perform maintenance as set out within the instruction manual.If the tool is disassembled or tampered with in any way.

Commercial ElectricAustralia/New Zealand (Head Office)1-23 Letcon Drive, Bangholme, Victoria, Australia 3175

•••

••

OW1

WARRANTYYOUR WARRANTY FORM SHOULD BE RETAINED BY YOU AT ALL TIMES. IN ORDER

TO MAKE A CLAIM UNDER THIS WARRANTY YOU MUST RETURN THE PRODUCT TO YOUR NEAREST BUNNINGS WAREHOUSE WITH YOUR BUNNINGS REGISTER RECEIPT.

PRIOR TO RETURNING YOUR PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR CUSTOMER SERVICE HELPLINE:

TO ENSURE A SPEEDY RESPONSE PLEASE HAVE THE MODEL NUMBER AND DATE OF PURCHASE AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY

OR PROCEDURE.

The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law.Our goods come with guarantees that cannot be excluded at law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. Generally you will be responsible for all costs associated with a claim under this warranty, however, where you have suffered any additional direct loss as a result of a defective product you may be able to claim such expenses by contacting our customer service helpline above.

`Australia 1800 069 486New Zealand 0508 069 486