11

A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

  • Upload
    others

  • View
    72

  • Download
    1

Embed Size (px)

Citation preview

Page 1: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4
Page 2: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

FINISH FLOOR

ELEV. @ 0"

FINISH FLOOR

ELEV. @ 0"

TOP OF BEARING

ELEV. @ 9'-4"

TOP OF BEARING

ELEV. @ 9'-4"

KEYSTONE

6" RAISED STUCCO BAND

11" DIAMOND PATTERN

SCORED STUCCO

12

5 12

5

1'-0"

6" RAISED STUCCO BAND

2'-0

"

6" RAISED STUCCO BAND

TILE INSET

6" RAISED

BAND

16080 OHGD 16080 OHGD

TILE ROOF

1'-10"6" 3'-8" 6"1'-9"

6"

5'-0

"2

'-0

"

R 1

'-10"

6"

5'-0

"2

'-0

"

1'-9"6" 3'-8" 6"1'-10"

R 1'-10"

1'-0"

FINISH FLOOR

ELEV. @ 0"

FINISH FLOOR

ELEV. @ 0"

TOP OF BEARING

ELEV. @ 9'-4"

TOP OF BEARING

ELEV. @ 9'-4"

6" RAISED BANDING

24" 72" TRANSOM 2-25 SH 2-25 SH3080 ENTRY 25 SH

12

5

12

5TILE ROOF

1'-0"

2'-0

"

2'-0"

1'-0"

1'-0"

8'-0

"

DECO TEXTURE FINISH

OVER CONCRETE BLOCK

6" RAISED

BANDING

3'-0" M

AX

BOTTOM OF VENT SHALL BE

LOCATED NO MORE THAN 3'-0"

BELOW THE RIDGE PER R806.2.2

FINISH FLOOR

ELEV. @ 0"

FINISH FLOOR

ELEV. @ 0"

TOP OF BEARING

ELEV. @ 9'-4"

TOP OF BEARING

ELEV. @ 9'-4"

2-25 SH

12

5

12

5

TILE ROOF

2-25 SH3-4080 SL. GL. DR. 3-4080 SL. GL. DR.

1'-0"

8'-0

"

1'-0"

WHERE THE ROOF FRAMING CONFLICTS

WITH THE ROOF VENTS, INSTALLATION OF

THE VENT MORE THAN 3'-0" BELOW THE

RIDGE IS ALLOWED PER R808.2.2

2 HR FIRE WALL

4'-0" 4'-0"

FINISH FLOOR

ELEV. @ 0"

FINISH FLOOR

ELEV. @ 0"

TOP OF BEARING

ELEV. @ 9'-4"

TOP OF BEARING

ELEV. @ 9'-4"

2'-0"

2'-0

"

6" RAISED BANDING

1'-0"

1'-0" 1'-0"

8'-0

"

24" 72" TRANSOM2-25 SH2-25 SH 3080 ENTRY25 SH

12

5

12

5TILE ROOF

DECO TEXTURE FINISH

OVER CONCRETE BLOCK

6" RAISED

BANDING

BOTTOM OF VENT SHALL BE

LOCATED NO MORE THAN 3'-0"

BELOW THE RIDGE PER R806.2.2

3'-0" M

AX

2'-8"

R 10"

R 9"

TYP.

1'-0

"

10

"

1" 10" 1"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-1

ELEVATION

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

3/16" = 1'-0"

FRONT ELEVATION

3/16" = 1'-0"

LEFT ELEVATION

3/16" = 1'-0"

REAR ELEVATION

3/16" = 1'-0"

RIGHT ELEVATION

Page 3: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

WH WH

1'-4" 12'-3" 14'-4" 14'-4" 12'-3" 1'-4"

13'-7" 28'-8" 13'-7"

55'-10"

11 1/2" 12'-3" 4 1/2" 14'-4" 14'-4" 4 1/2" 12'-3" 11 1/2"

1'-4

"8

'-8

"2

4'-8

"4

'-8

"2

7'-0

"1

3'-8

"

8'-3" 2'-0" 16'-0" 1'-8"1'-8" 16'-0" 2'-0" 8'-3"

27'-11" 27'-11"

55'-10"

11

'-4

"6

'-0

1/2

"1

0'-9

1/2

"1

2'-6

"2

'-6

"4

'-4

"5

'-4

"3

'-6

"1

3'-8

"

8'-11" 3'-4" 9'-1 1/2" 4'-4" 4'-1" 4'-8" 9'-1 1/2" 3'-4" 8'-11"

22

'-1

0"

3'-2

"3

'-5

"1

4'-3

1/2

"1

3'-9

1/2

"

11

'-4

"6

'-0

1/2

"1

0'-9

1/2

"1

2'-6

"2

'-6

"4

'-4

"2

'-0

"3

'-4

"3

'-6

"1

3'-8

"

22

'-1

0"

3'-2

"3

'-5

"1

4'-3

1/2

"1

3'-9

1/2

"

2'-4 1/2" 6'-6 1/2"

1'-4

"8

'-8

"2

4'-8

"4

'-8

"2

7'-0

"1

3'-8

"

80

'-0

"

ELEV. @ 0'-0"

ELEV. @ 0'-(-4")

ELEV. @ 0'-(-4")

TIL

E S

HO

WER

RECES

S 3

-1/2

"

16'-0" X 8'-0" O.H. GARAGE DR.

PROVIDE 1/4" WATER

LINE @ REF. SPACE

FOR ICE MAKER

RECES

S

RUN CONDUIT FOR

ELECTRIC AT ISLAND

TIL

E S

HO

WER

RECES

S 3

-1/2

"

16'-0" X 8'-0" O.H. GARAGE DR.

ELEV. @ 0'-(-4")

2" SLOPE

6" X 12" RECESS 6" X 12" RECESS

INSTALL 1 3/8" THICK SOLID

WOOD DOOR BETWEEN LIVING

AND GARAGE PER FLORIDA

BUILDING CODE R302.5.1.

#5 BAR IN GROUTED CELL, LAP

25" WITH #5 DOWEL OUT OF

SLAB, WITH 7" HOOK INTO TOP

OF BOND BEAM

ELEV. @ 0'-(-4")

2" SLOPE

ELEV. @ 0'-0"

ELEV. @ 0'-(-4")

INSTALL 1 3/8" THICK SOLID

WOOD DOOR BETWEEN LIVING

AND GARAGE PER FLORIDA

BUILDING CODE R302.5.1.

SET A/C PAD ABOVE

FLOOD ELEV W/ 1'-0"

FREEBOARD PER FBCR

R322.2.1

RUN CONDUIT FOR

ELECTRIC AT ISLAND

19'-4 1/2" 8'-6 1/2" 8'-6 1/2" 19'-4 1/2"

STANDARD SGD RECESS1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

4'-11" 13'-6" 9'-6" 9'-6" 13'-6" 4'-11"

8 1

/2"

3'-3

"8

1/2

"

ELEV. @ 0'-(-4") 8 1

/2"

3'-3

"8

1/2

"

8F8-1B SET AT GARAGE DOOR HEAD

HEIGHT, ADD COURSING AS

REQUIRED TO 8X8 BOND BEAM W/ 1

#5 TOP @ 9'-4". GROUT ALL SOLID.

8F8-1B SET AT GARAGE DOOR

HEAD HEIGHT, ADD COURSING AS

REQUIRED TO 8X8 BOND BEAM W/ 1

#5 TOP @ 9'-4". GROUT ALL SOLID.

F3F3

F3

F3

F3

F3

F6A

F3 W

/ CURB

F5 W

/ CURB

F6

F3

F3

F3

F3

F3 W

/ CURB

F6A

F6

F5 W

/ CURB

F3

F3

F3

F3

F3

F3

F3

F3

F3 F3

F5

F5

F6A

SIN

K &

DIS

P.

SIN

K &

DIS

P.

5'-0" TUB 5'-0" TUBW W

C

RECES

S

6'-6 1/2" 2'-4 1/2"

P

P

P

P

PP

4" SLAB W/ 2,500 PSI CONC. W/ 6X6 #

10/10 W.W.M. REINFORCING OVER 6

MILL VISQUEEN BARRIER ON

MECHANICALLY COMPACTED FILL @ 95%.

THE FINISH FLOOR SLAB SHALL BE SET

ABOVE BASE FLOOD ELEVATION PER FEMA

FLOOD MAP PLUS 1'-0" FREEBOARD PER

FBCR R322.2.1. SEE SITE PLAN BY OTHERS

ELEV. @ 0'-0"

LOWEST POINT OF GARAGE SHALL BE SET ABOVE

BASE FLOOD ELEVATION PER FEMA FLOOD MAP

SET A/C PAD ABOVE

FLOOD ELEV W/ 1'-0"

FREEBOARD PER FBCR

R322.2.1

SET W/H ABOVE

FLOOD ELEV W/ 1'-0"

FREEBOARD PER FBCR

R322.2.1

SET W/H ABOVE

FLOOD ELEV W/ 1'-0"

FREEBOARD PER FBCR

R322.2.1

80'-0"

2 HOUR FIREWALL USING 2

HOUR FIRE RATED 8" MASONRY

PER FBC 721 "PRESCRIPTIVE FIRE

RESISTANCE" SEE TABLE ON

SHEET A4

A A

F6A

PROVIDE TERMITE TREATMENT

WITH "BORA CARE"

STANDARD SGD RECESS1-1/2".

IMPACT GLASS SGD RECESS 2-1/2".

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN.

2 #5 CONT. W/

3" CLEAR COVER.

1'-0"

1'-0"

MIN

.

2'-1

"

1'-8

"

FIN. GRADE

#5 DOWEL WITH

7" HOOK, EMBED

5" MIN. BELOW

GARAGE FLOOR

2 #5 CONT. W/

3" CLEAR COVER.1'-0"

1'-0"

MIN

.

7 5/8"

.

VARIES WITH

SLOPE OF FLOOR

2'-1

"

CURB IS OPTIONAL & NOT INCLUDED

IN FOOTING DIMENSIONS

(2) #5 RODS CONT. W/

3" CLEAR COVER

1'-0

"

1'-4"

8"X8" CONC. RIBBON

W/ 1 #5 ROD CONT.

1" 3"

8"

8"

PAVERSMORTAR

TYPE LENGTH WIDTH DEPTH

2'-6" 2'-6"

3'-0"3'-0"

3'-6"3'-6"

4'-0"4'-0"

5'-0"5'-0"

A

B

C

D

E

1'-0"

1'-0"

1'-0"

1'-2"

1'-2"

3-#5 3-#5

4-#5 4-#5

4-#5 4-#5

5-#5 5-#5

6-#5 6-#5

-

-

-

-

-

REMARKSLONG WAY SHORT WAY

BOTTOM REINF.

PAD FOOTING SCHEDULE

US

ED

TYPE LENGTH WIDTH DEPTH

CONT. 1'-4"

1'-8"

1'-0"

1'-4"

1'-4"

F1

F2

F3

F4

F5

1'-8"

1'-0"

1'-0"

2-#5

SHAPE

WALL FOOTING SCHEDULE

US

ED BOTTOM

REINFORCING

F6

F6A

TE

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

CONT.

1'-4"

0'-8"

0'-8" 0'-8"

0'-8"

1'-8"

0'-10"

0'-8"

2-#5

2-#5

2-#5

2-#5

2-#5

1-#5

1-#5

ADD CURB TO

GARAGE, SEE

DETAIL

PROVIDE CORNER BARS PER 6/S-1

FOUNDATION PLAN

PLAN NOTES:

1. TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0"

2. "F#" DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET.

3. # DENOTES PAD FOOTING AT CONCENTRATED LOADS PER SCHEDULE THIS SHEET.

4. PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM FOOTING

TO BOND BEAM.

5. ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES MAY

EXTEND BEYOND FACE OF WALL.

6. FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/

DOOR SUPPLIER.

7. PROVIDE PRESSURE TREATED BUCKS AT WINDOWS/ DOORS PER DETAIL 7/S-1.

SCALE: 3/16" = 1'-0"

(2) #5 RODS CONT. W/

3" CLEAR COVER

MIN

.

1'-0

"

1'-4"

7 5/8"

2'-1

"

CURB IS OPTIONAL & NOT INCLUDED

IN FOOTING DIMENSIONS

#5 DOWEL W/ 7"

HOOK, EMBED 5"

MIN. BELOW

GARAGE FLOOR

v

VARIES WITH

SLOPE OF FLOOR

3" CLEAR COVER1 #5

8"

8"

3" CLEAR COVER2 #5

8"

1'-4"

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-2

FOUNDATION

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

3/16" = 1'-0"

FOUNDATION PLAN

1/2" = 1'-0"

"F3" FOOTING

1/2" = 1'-0"

"F3" WITH CURB AT GARAGE

1/2" = 1'-0"

"F5" FOOTING

1/2" = 1'-0"

"P" PAVERS DETAIL ENTRY/ LANAI

1/2" = 1'-0"

"F5" W/ CURB FOOTING

1/2" = 1'-0"

"F6A"

1/2" = 1'-0"

"F6" STEP DOWN

Page 4: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

WH WH

PLAN NOTES

1) VERIFY ALL ROUGH OPENING DIMENSIONS FOR

ALL WINDOWS AND DOORS

2) PROVIDE SAFETY GLAZING WITHIN 24" FROM EXIT

PER FLORIDA BUILDING CODE R 308.4.2.

3) PROVIDE SAFETY GLAZING AT BATH/ SHOWER

PER FLORIDA BUILDING CODE R 308.4.5.

4) NON BEARING INTERIOR FRAME WALLS SHALL BE

FRAMED W/ WOOD OR METAL STUDS. SPACING SHALL

NOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)

5) PROVIDE DEAD WOOD IN ATTIC FOR OVERHEAD

GARAGE DOOR HARDWARE

6) KITCHEN KNEE WALL TO BE FRAMED W/ TOP @

34 1/2" A.F.F.

7) INSTALL SMOOTH WALLS IN KITCHEN AND ALL

BATHROOM AREAS

8) WHERE DRYWALL CEILING IS APPLIED TO TRUSSES

@ 24" O.C. USE 5/8" DRYWALL OR 1/2" SAG

RESISTANT PER SEC. 702.3.5

9) THE GARAGE SHALL BE SEPARATED FROM THE

RESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUM

BOARD APPLIED TO THE GARAGE SIDE. GARAGES

BENEATH HABITABLE ROOMS SHALL BE SEPARATED

WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD

OR EQUIVALENT. WHERE THE SEPARATIION IS A

FLOOR - CEILING ASSEMBLY, THE STRUCTURE

SUPPORTING THE SEPARTION SHALL ALSO BE

PROTECTED BY NOT LESS THAN 1/2" GYPSOM BOARD

OR EQUIVALENT

10) INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEEN

LIVING AND GARAGE PER FLORIDA BUILDING CODE

R302.5.1,

11) ALL WINDOWS INSTALLED 72" ABOVE GRADE MUST

COMPLY WITH R612.2 MIN 24" SILL HEIGHT OR

PROVIDED WITH AN APPROVED WINDOW FALL

PRVENTION DEVICE

12) ALL CLOSET SHELVES TO BE 12". ALL PANTRY &

LINEN TO BE (4)-16" SHELVES 18" 0.F.F. W/ 15"

INCREMENT.

13) ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BE

INSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.

DOOR HEADERS6'-8" BI-FOLD

6'-8" SWING

8'-0" SWING

HEADER HEIGHT 82" A.F.F.

82 1/2" A.F.F.

98 1/2" A.F.F.

HEADER HEIGHT

HEADER HEIGHT

CABINET BACKING

KITCHEN

MASTER BATH

GUEST BATH

LAUNDRY ROOM

UPPER TOP @ 84" BASE TOP @ 35"

UPPER

UPPER

UPPER TOP @ 84"

BASE TOP @ 35"

BASE TOP @ 31"

BASE

SQUARE FOOTAGE UNIT 1

LIVING AREA

GARAGE AREA

LANAI AREA

FRONT PORCH/ ENTRY AREA

1,513

433

146

29

TOTAL SQUARE FOOTAGE 2,121

SQUARE FOOTAGE UNIT 2LIVING AREA

GARAGE AREA

LANAI AREA

FRONT PORCH/ ENTRY AREA

1,513

433

146

29

TOTAL SQUARE FOOTAGE 2,121

13'-7" 14'-4" 14'-4" 13'-7"

1'-4" 12'-3" 4'-4" 10'-0" 3'-8" 10'-8" 12'-3" 1'-4"

5'-0

"6

'-0

"6

'-5

"3

'-5

"3

'-1

0"

5'-2

"1

'-1

0"

1'-1

1"

3'-2

"2

'-4

"8

'-5

"2

'-0

"3

'-4

"1

7'-2

"

14'-0 1/2" 5'-5" 3'-8" 4'-9 1/2" 4'-6" 3'-8" 5'-5" 14'-4"

4'-11" 10'-6 1/2" 3'-8" 2'-0" 6'-9 1/2" 6'-6" 2'-0" 3'-8" 10'-10" 4'-11"

1'-1" 12'-0" 6"

27'-11" 27'-11"

1'-4

"8

'-8

"5

'-4

"1

0'-4

"9

'-0

"

10

'-0

"2

4'-8

"4

'-8

"2

7'-0

"1

3'-8

"

2'-6

"9

'-6

"1

5'-0

"

80

'-0

"

29

'-1

0"

10

'-4

"1

2'-4

"3

'-1

0"

8'-5 1/2" 3'-5 1/2" 3'-8" 5'-10" 3'-10" 2'-8" 2'-4 1/2" 3'-10" 5'-10" 3'-8" 3'-9" 8'-5 1/2"

2 CAR GARAGE

ENTRY

NOTE: THE GARAGE SHALL BE SEPERATED

FROM THE RESIDNECE AND ATTIC AREA BY

NOT LESS THEN 1/2" GYPSUM BOARD APPLIED

TO THE GARAGE SIDE.

NOTE: INSTALL 1-3/8" THICK SOLID

WOOD DOOR BETWEEN LIVING AND

GARAGE PER R302.5.1.

BEDROOM # 2

LANAIMASTER SUITE

KITCHEN

GREAT ROOM

DB S

INK

ESC

APE D

W

DEN

OVERH

EAD C

ABIN

ETS

12" VINYL SHELVING

RANG

E

W/ H

OO

D

EG

RES

SEG

RES

S

EGRESS

EGRESS

B

2

2

5

2

2

2

1

3

C

B

B

A

VERIFY LOCATION W/ SITE

PLAN, A/C NOT TO

ENCROACH EASEMENT

8'-3" 2'-0" 16'-0" 1'-8"1'-8" 16'-0" 2'-0" 8'-3"

27'-11" 19'-8" 8'-3"

15

'-0

"5

'-0

"1

'-0

"

MIN. R-13

INSULATION

W

NOTE: THE GARAGE SHALL BE SEPERATED

FROM THE RESIDNECE AND ATTIC AREA BY

NOT LESS THEN 1/2" GYPSUM BOARD

APPLIED TO THE GARAGE SIDE.

NOTE: INSTALL 1-3/8" THICK SOLID

WOOD DOOR BETWEEN LIVING AND

GARAGE PER R302.5.1.

TILE

SHOWER

RECESS

3-1/2"

DB S

INK

MIR

ESC

APED

W

A/H

OVERH

EAD C

ABIN

ETS

12" VINYL SHELVING

RANG

E

W/ H

OO

D

EG

RESS

EG

RESS

EGRESS

EGRESS

VERIFY LOCATION W/ SITE

PLAN, A/C NOT TO

ENCROACH EASEMENT

2 CAR GARAGE

ENTRY

UTILITY

BEDROOM # 2

MASTER

BATH

LANAIMASTER SUITE

KITCHEN

GREAT ROOM

DEN

B

3

C

B

2

B

A

1

2

2

10

'-0

"2

4'-8

"4

'-8

"2

7'-0

"1

3'-8

"

2'-6

"9

'-6

"1

5'-0

"

80

'-0

"

15

'-0

"5

'-0

"1

'-0

"

55'-10"

5

5

55'-10"

6'-2 1/2" 2'-8 1/2" 3'-0" 16'-0" 15'-8 1/2" 3'-3 1/2" 2'-5" 6'-6"

D

MIR

5'-0" TUB

BATH #2

2

2

2

2 5 5

29

'-1

0"

10

'-4

"1

2'-4

"3

'-1

0"

MASTER

BATH

TILE

SHOWER

RECESS

3-1/2" MIR

A/H

12" VIN

YL

SHELV

ING

2 2

2

5

2

MIN. R-13

INSULATION

D W

UTILITYBATH #2

MIR

5'-0" TUB

4X16" VNL SHLVNG

2017

ACCESSIBLE

4X16" SHLV

2

22

2

5

3'-8

"

2" X 4" SPF # 2 PT.

STUDS AT 16" O.C.

BEARING WALL

2

2

5

2

2

2

2

9'-0

"1

0'-4

"5

'-4

"1

0'-0

"

6" 12'-0" 1'-1"

22

'-6

"8

'-5

"2

'-4

"3

'-2

"1

'-1

1"1

'-1

0"

5'-2

"3

'-1

0"

3'-5

"6

'-5

"6

'-0

"5

'-0

"

9'-6" 9'-6"

4" BEARING

WALL

16'-0" X 8'-0" O.H. GARAGE DOOR

W.I.C. W.I.C. W.I.C.W.I.C.

9'-4" FLAT CEILING9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT

CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

2017

ACCESSIBLE

ATTIC ACCESS ATTIC ACCESS

UNIT #1 UNIT #2

16'-0" X 8'-0" O.H. GARAGE DOOR

4X16" VNL SHLVNG4X16" SHLV

4X16" SHLV

4X16" SHLV

12" VIN

YL

SHELV

ING

12" VIN

YL

SHELV

ING

12" VIN

YL

SHELV

ING

5

5

+33.5/-44.8 +33.5/-44.8

+33

.5/-4

4.8

+33

.5/-4

4.8

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+33

.5/-3

6.3

+28.2/-31.5 +28.2/-31.5

+29.4/-33.3 +29.4/-33.3

4X16" VNL SHLVNG4X16" VNL SHLVNG

2 HOUR FIREWALL USING 2

HOUR FIRE RATED 8" MASONRY

PER FBC 721 "PRESCRIPTIVE FIRE

RESISTANCE" SEE TABLE ON

SHEET A4

INTERIOR DOOR SCHEDULE

MARK

1

2

3

DOOR WIDTH NOTES

P.K. = POCKET DOOR

B.F. = BI-FOLD DOOR

B.P. = BI-PASS DOOR

L.V. = LOUVERED DOOR

4

5

6

7

8

3'-0"

2'-8"

2'-6"

2'-4"

2'-0"

1'-8"

1'-6"

2'-11"

TOILET PAPER ROLL

2'-6"

1'-8"

TOWEL BAR

4'-0"

3'-2"

MIN.

4"

MIN.

4"

BATHROOM NOTES

ALL TUB DECKS @ 21" A.F.F

ALL BLOCKING TO BE PT IN SHOWERS

TOWEL BAR

TP TOILET PAPER

TB

FACE OF OUTSIDE WALL TO FACE OF STUD WALL FACE OF STUD TO FACE OF STUD

1/2"

3 1/2"

1/2"

FACE OF EXTERIOR WALL

1/2"

3 1/2"

1/2"TYPICAL DIMENSION STRING

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-3

FLOOR

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

DOOR SCHEDULETYPE

MARK DESCRIPTION MANUFACTURER HEIGHT WIDTH ZONE 4 ZONE 5 QTY

1 16080 OHGD GARAGE DOOR 8'-0" 16'-0" +28.2/-31.5 +28.2/-31.5 2

2 3080 ENTRY DISTINCTION 8'-0" 3'-0" +33.5/-36.3 +33.5/-44.8 2

3 (3)-4080 SL. GL. DR. DISTINCTION 8'-0" 12'-0" +29.4/-33.3 +29.4/-33.3 2

WINDOW SCHEDULE MARK DESCRIPTION MANUFACTURER HEIGHT WIDTH ZONE 4 ZONE 5 QTY

A 25 SH 5'-3" 3'-2" +33.5/-36.3 +33.5/-44.8 2

B 2-25 SH 5'-3" 6'-4" +33.5/-36.3 +33.5/-44.8 6

C 24"X72" FIXED GLASS 2'-0" 6'-0" +33.5/-36.3 +33.5/-44.8 2

GARAGE DOOR ASSUMES 2' IN ZONE 5.

3/16" = 1'-0"

FLOOR PLAN

WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND

CONVERTED TO ALLOWABLE STRESS DESIGN PRESSURES USING

0.6W LOAD FACTOR. Vasd=124 MPH

WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND

CONVERTED TO ALLOWABLE STRESS DESIGN PRESSURES USING

0.6W LOAD FACTOR. Vasd=124 MPH

Page 5: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

WH WH

MG

1

J1

J3

J5

EJ7

J5

J3

J1

J1

J3

CJ1

0

J5

CJ1

1

EJ7

J5

J3

J1

A1

A2

A3

A4

A5

A6

A7

A8

A9

A10

A11

A12

A15

A16

A17

A18

A19

A20

A7

A8

A9

A10

A18

A8

A9

A5

A16

A2

A19

A10

A7

A8

A4

A17

A9

A10

A6

A3

A7

A15

A11

A12

J5

J3

J1

J5

J3

J1

CJ1

0

A1

A20

B1

B2

B3

B4

B5

B6

B7

B8

B9

B10

B11

B12

GE11

EJ8A

V1

V2

V3

V4

V5

V6

MG

1

J1

J3

J5

EJ7

J1

J3

CJ1

1

J5

EJ7

J1

J3

J5

EJ7

J1

J3

CJ1

1A

J5

EJ7

EJ8A

EJ8

EJ8B

EJ8

EJ8B

A13

A14

A13

A14

EJ7A

2 CAR GARAGE

ENTRY

UTILITY

BEDROOM # 2

BATH

#2

MASTER

BATH

LANAIMASTER SUITE

KITCHEN

W.I.C. W.I.C.GREAT ROOM

DEN

2 CAR GARAGE

ENTRY

UTILITY

BEDROOM # 2

BATH

#2

MASTER

BATH

LANAIMASTER SUITE

KITCHEN

W.I.C.W.I.C.GREAT ROOM

DEN

9'-4" FLAT CEILING

HIP

HIP

HIPH

IP HIP

HIP

HIP

VAL

LEY V

ALLEY

RID

GE

RID

GE

RID

GE

8F16-1B/1T 8F8-0B

8F1

6-1

B/1

T8

F8

-0B

8F8

-0B

8F8

-0B

8F8

-1B

8F8

-0B

8F8

-0B

8F16-1B/1T8F8-0B

8F1

6-1

B/1

T8

F8

-0B

8F8

-0B

8F8

-0B

8F8

-1B

8F8

-0B

8F8

-0B

8F8-1B SET AT GARAGE DOOR HEAD

HEIGHT, ADD COURSING AS REQUIRED TO

8X8 BOND BEAM W/ 1 #5 TOP @ 9'-4".

GROUT ALL SOLID.

THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE & ATTIC

BY NOT LESS THEN 1/2" GYPSUM BOARD APPLIED TO THE GARAGE

SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE

SEPARATED WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD

OR EQUIVALENT. WHERE THE SEPERATION IS A FLOOR-CEILING

ASSEMBLY THE STRUCTURE SUPPORTING THE SEPERATION SHALL

ALSO BE PROTECTED BY NOT LESS THAN 1/2" GYPSUM BOARD

OR EQUIVALENT

#5 VERTICAL @ DOT

LOCATION (48" O.C. MAX) IN

GROUTED CELL W/ 7" HOOK

INTO BOND BEAM

CORNER BARS IN

BOND BEAM PER

8/S-1

SEE DETAIL 9/S-1 WHERE

LINTEL AT LANAI/ENTRY

INTERSECTS MAIN WALL,

TYPICAL

EXTERIOR CEILING

PER 2/S-1

EXTERIOR CEILING

PER 2/S-1

THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE &

ATTIC BY NOT LESS THEN 1/2" GYPSUM BOARD APPLIED TO THE

GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL

BE SEPARATED WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM

BOARD OR EQUIVALENT. WHERE THE SEPERATION IS A FLOOR-

CEILING ASSEMBLY THE STRUCTURE SUPPORTING THE

SEPERATION SHALL ALSO BE PROTECTED BY NOT LESS THAN

1/2" GYPSUM BOARD OR EQUIVALENT

#5 VERTICAL @ DOT

LOCATION (48" O.C. MAX)

IN GROUTED CELL W/ 7"

HOOK INTO BOND BEAM

CORNER BARS IN

BOND BEAM PER 8/S-1

SEE DETAIL 9/S-1 WHERE

LINTEL AT LANAI/ENTRY

INTERSECTS MAIN WALL,

TYPICAL

EXTERIOR CEILING

PER 2/S-1

STUD BEARING WALLS, 2X4

OR 2X6 SPF#2 @ 16" O.C.,

BLOCKING AT MID HEIGHT.

SPTH4 OR SPTH6 TOP &

BOTTOM @ 16" O.C. PT

SILL PLATE W/ 1/2" X 6"

EXPANSION BOLTS @ 32"

OC. W/ 2" WASHER.

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING 9'-4" FLAT CEILING

9'-4" FLAT

CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING9'-4" FLAT CEILING

9'-4" FLAT

CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

9'-4" FLAT CEILING

SEE DETAIL 9/S-1 WHERE LINTEL

AT LANAI/ENTRY INTERSECTS

MAIN WALL, TYPICAL

SEE DETAIL 9/S-1 WHERE LINTEL

AT LANAI/ENTRY INTERSECTS

MAIN WALL, TYPICAL

ROOF SHEATHING SHALL BE FIRE

RETARDANT TREATED PLYWOOD

WITHIN 4'-0" OF EACH SIDE OF

DIVIDING WALL PER FBC 706.4.1.1

8" X 8" CONTINUOUS

MASONRY BOND BEAM AT

TOP OF WALL WITH 1 #5

BARS

NO GABLE BRACE REQUIRED

OUTLOOKERS PER 13/S-1

PROVIDE UL #301

DETAIL WITHIN EAVE

PROVIDE UL #301

DETAIL WITHIN

EAVE

8" X 8" CONTINUOUS

MASONRY BOND BEAM

AT TOP OF WALL WITH 1

#5 BARS

4'-0" 4'-0"

2 HOUR MASONRY

WALL PER SHEET

S-2

9'-4" FLAT

CEILING9'-4" FLAT

CEILING

ATTIC

ACCESS

ATTIC

ACCESS

1-HTA16-18

@ A1

1-HTA16-18

@ A1

1-HTA16-18,

TYP.1-HTA16-18,

TYP.

1-HTA16-18 @ 32"

O.C. @ INSIDE FACE

OF GABLE

8F8-1B

1-MTW16 @

TRUSS TO STUD

WALL,TYP.

S-3

2

S-3

1

OUTLOOKER

PER 12/S-1

8F8-1B

R.V. R.V.

R.V

.R.V

.R.V

.R.V

.

SOFFITS DO NOT MEET A/150

RULE FOR ATTIC VENTILATION.

THERFORE, RIDGE VENTS ARE

REQUIRED SEE TABLE.

WHERE ROOF SHEATHING CONTACTS

ONLY THE EDGE OF ROOF TRUSSES,

INSTALL BEVELED BLOCKING PER

DETAIL THIS SHEET (DR HORTON

COMPANY REQUIREMENT)

2 HOUR FIREWALL USING 2

HOUR FIRE RATED 8" MASONRY

PER FBC 721 "PRESCRIPTIVE FIRE

RESISTANCE" SEE TABLE ON

SHEET A4

1-HTA16-18

TYP.

1-HTA16-18

TYP.

1-HTA16-18

@ A20

1-HTA16-18

@ A20

1-MTW16

@ B12

2-MTW16

@ A20

2-2X12 HEADER

W/ 1-MSTAM18

EACH END

2-2X12 HEADER

W/ 1-MSTAM18

EACH END 1-MTW16

@ B1

2-MTW16

@ F1

1-MTW16

TYP.

1-MTW16

TYP.

NO GABLE BRACE REQUIRED

1-HTA16-18

@ B12

1-HTA16-18

@ EJ7

STUD BEARING WALLS, 2X4 OR 2X6

SPF#2 @ 16" O.C., BLOCKING AT

MID HEIGHT. SPTH4 OR SPTH6 TOP

& BOTTOM @ 16" O.C. PT SILL

PLATE W/ 1/2" X 6" EXPANSION

BOLTS @ 32" OC. W/ 2" WASHER.

STUD BEARING WALLS, 2X4 OR

2X6 SPF#2 @ 16" O.C.,

BLOCKING AT MID HEIGHT. SPTH4

OR SPTH6 TOP & BOTTOM @ 16"

O.C. PT SILL PLATE W/ 1/2" X 6"

EXPANSION BOLTS @ 32" OC. W/

2" WASHER.

12

S-1

5'-0"

1-HTA16-18

@ A1

1-HTA16-18

@ A1

TRUSS STRAPPING TO MASONRY

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1615

1870

2430 (1 PLY)

2800 (2 PLY)

3170 (2 PLY)

5005

(1) HTA16-18

(1) HTA20

(2)HTA16- 18

(2)HTA16 -18

(2) HTA20

HTT45

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx1/2", EMBED 4"

10-10dx 1/2", EMBED 4"

5/8"ø ATR, EPOXY 12"

INSTALL HTA

16-18 AT ALL

TRUSSES TO

1615 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE AND SUITABLE FOR THE GEOMETRY. EMBED STRAP

ON -C/L OF WALL.

2. CONNECTORS ARE USP STRUCTURAL CONNECTORS. ALL CONNECTORS

SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED

INSTUCTIONS. SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE

ENGINEER OF RECORD.

3. WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL

RETROFIT STRAP PER 10/S-1.

4. ' ATR' = ALLTHREAD. DRILL AND EPOXY WITH USP EPOXY PER MFR.

INSTRUCTIONS. REV2

TRUSS STRAPPING TO STUDWALL/ WOOD BEAM

MAX TRUSS UPLIFT

@ 24" OC (LBS)CONNECTOR FASTENER

1005

2010

3015

1285

2570

3855

5140

(1)MTW16

(2) MTW16

(3) MTW16

(1) HTW20

(2) HTW20

(3) HTW20

(4) HTW20

12-10dX1~1/2"

12-10dX1~1/2"

12-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

24-10dX1~1/2"

INSTALL AT ALL

TRUSSES TO

1005 lb UPLIFT.

FOR HIGHER

UPLIFTS, SEE

NOTES ON

PLAN.

NOTES:

1. PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING

POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED

TRUSS DESIGN PACKAGE.

2. CONNECTORS ARE USP STRUCTURAL CONNECTORS. ALL CONNECTORS

SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED

INSTUCTIONS. REV2

WALL ABOVE WITH BOND

BEAM AT TOP

#5 VERTICAL, ABOVE

LINTEL ONLY WHERE

NOTED ON PLAN

'1B' DENOTES 1#5 BOTTOM

WITH 7" HOOK EACH END OR

EXTEND 24" BEYOND OPENING.

'0B' DENOTES "NO REBAR"

8" PRECAST LINTEL

GR

OU

T S

OLID

1'-4"

GR

OU

TE

D1#5 TOP

1#5 BOTTOM

8F8-1B

8F8-0B

8F16-1B/1T

PRECAST LINTEL SCHEDULE

AT SWING DOORS, USE 2" RECESS STYLE

LINTEL IF NEEDED FOR ROUGH OPENING.

LINTELS BEAR 4" MIN. EACH END

PLAN NOTES:

1. ROOF AND FLOOR TRUSS BEARING ELEVATION VARIES,

SEE LEGEND.

2. ROOF AND FLOOR FRAMING SHALL BE WOOD TRUSSES

DESIGNED BYA DELEGATED TRUSS ENGINEER PER

DESIGN CRITERIA ON SHEET S-1.

3. PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS

SHEET.

4. FOR NAILING OF ROOF AND FLOOR DECK, SEE 1 AND 2

ON S-1.

5. 8F8-1B etc., DENOTES PRECAST LINTEL ABOVE

DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET.

6. AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND

BEAM W/ 1 #5 CONTINUOUS, SEE DETAIL 11/S-1.

BEARING HEIGHT

= BEARING @ 9'-4"

= FULL HEIGHT

WALL PER 6/S-2

MINIMUM EQUIVALENT THICKNESS1 (IN) BEARING

OR NON-BEARING CONCRETE MASONRY WALLS

F.B.C. TABLE 722.3.2

TYPE OF AGGREGATEFIRE - RESISTANCE RATING (HOURS)

1. PUMICE OR EXPANDED SLAG

2. EXPANDED SHALE, CLAY OR SLATE

3. LIMESTONE, CINDERS, OR

UNEXPANDED SLAG

2 HR

3.2"

3.6"

4.0"

FOR THE 2 HOUR FIREWALL, PURCHASE ONLY BLOCK WITH 2 HOUR FIRE

RATED MARKING, LABEL OR DOCUMENTATION.

2 HOUR FIREWALL USING 8" MASONRY PER

FBC 721 "PRESCRIPTIVE FIRE RESISTANCE"

4.2"4. CALCAREOUS OR SILICEOUS

GRAVEL

MODEL 1526 VILLA (EACH UNIT): ATTIC VENTILATION FBCR R806

SOFFIT ONLY (1/150) WITH ROOF VENTS (1/300)

AREAS (SQ. FT.) ATTIC VENTILATION REQUIRED ATTIC VENTILATION REQUIRED

MARK SOFFIT

2100.0 SQ. FT.

ATTIC AREA/150

10.20% 7.0 SQ. FT. 2.98%

COORDINATE VENTING REQUIREMENTS WITH ENERGY CALCULATIONS

(R.V.)

ROOF VENTS ARE REQUIRED

32" BASE

22

-3/8

" BASE

LOMANCO 770-D

0.97 SQ. FT. FREE AIR

(NO ROOF VENTS)

14.0 SQ.FT.

"SOFFIT ONLY" DOES NOT QUALIFY

SOFFIT MODEL

ACM QUAD 4, FULL VENT,

NARROW PATTERN,

8.15% FREE AIR FLOW

ATTIC

137.3 SQ. FT.

MIN AIR FLOW OF SOFFIT

ROOF VENT MODEL

1st STORY

REQ'D AIR FLOW

OF SOFFIT

QUAD 4 SOFFIT

HAS

8.15%

ATTIC AREA/300QUANTITY OF

ROOF VENTS

3

ROOF SHEATHING

8d RING SHANK @

6" O.C.

16d NAILS

@ 8" O.C.

2" X () BLOCKING W/

BEVEL CUT TOP

ROOF TRUSS

BEVELED BLOCKING DETAIL

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-4

ROOF

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

3/16" = 1'-0"

ROOF FRAMING PLAN

TRUSS BEARING CONDITIONS AND

STRAPPING BASED ON TRUSS LAYOUT

PREPARED BY SCOSTA JOB#: 44151GB

DATED: 06/18/19 REVISED: 09/30/19

Page 6: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

WH WH

P

P

P

P

TV TV

TVTV

TV

TV

TV TV

J

ELECTRICAL NOTES:

ALL OUTLETS IN WET AREAS AND ALL

ALL ELECTRIC, ELECTRICAL EQUIPMENT AND APPLIANCES TO BE SET AT

OR ABOVE BASE FLOOD ELEVATIONS PLUS 1'-0" FREEBOARD.

ARC-FAULT CIRCUIT-INTERRUPTERS AND TAMPER

RESISTANT RECEPTACLES SHALL BE INSTALLED

INSTALL PHONE AND T.V PER CONTRACT.

IN DWELLING UNITS PER N.E.C 210.12 AND 406.11

EXTERIOR OUTLETS TO BE GFI'S.

NOTE: NOT ALL SYMBOLS ARE USED FOR THIS

PROJECT.

SURFACE MOUNTED CEILING LIGHT

TELEVISION RECEPTION OUTLET

AC/DC SMOKE DETECTOR

TO BE INTERCONNECTED

WALL MTD. BRACKET LIGHT

DIMMER SWITCH

3 WAY SWITCH

SINGLE POLE SWITCH

TELEPHONE OUTLET

MOTION SENSOR SWITCH

A/C DISCONNECT

DUPLEX FLOOD LIGHT

TRACK MTD. LIGHTS

EXHAUST FAN

PUSH BUTTON (PB) / DOOR BELL (DB)

FLUSH MOUNTED LIGHT

1/2 SWITCHED DUPLEX OUTLET

DUPLEX RECEPTACLE OUTLET

4-PLEX RECEPTACLE OUTLET

220 V RECEPTACLE OUTLET

SINGLE RECEPTACLE OUTLET

DUPLEX RECEPTACLE AT ELEV. A.F.F.

ELECTRICAL PANEL

ELECTRICAL METER

120 V JUNCTION BOX

DUPLEX RECEPTACLE - ABOVE COUNTER

3

D

SD

TV

ELECTRICAL LEGEND

2' UNDER COUNTER LIGHT

4' FLUORESCENT LIGHT

INTERCOMIC

KP

KEYPAD

ANY RESIDENT HAVING A FOSSIL-BURNING

HEATER OR APPLIANCE, A FIREPLACE, OR

AN ATTACHED GARAGE SHALL HAVE AN

OPERATIONAL CARBON MONOXIDE ALARM

INSTALLED WITHIN 10 FEET OF EACH

ROOM USED FOR SLEEPING PERPOSES.

PER RULE 9B-3.04.72

SD (SMOKE DETECTOR)

SCD (CARBON MONOXIDE/ SMOKE

DETECTOR)

AFF

MS

INSTALL ALL ELECTRICAL PER NEC 2014

SCD

T

ELECTRICAL PLAN

200 AMP SERVICE

TAG

A

B

C

D

E

F

G

H

I

J

K

L

M

N

O

P

Q

QUANTITY PRODUCT

(26)

(4)

(4)

(8)

(2)

(4)

(X)

(2)

(X)

(1)

(2)

(X)

(X)

(X)

(X)

(X)

(X)

(FLUSH MOUNTED LT)

(VAPORS)

(PENDANT LIGHT

(10" MUSHROOMS)

(24" AVALON 3 LT)

(36" AVALON 4 LT)

(NOT USED)

(COACH LIGHTS)

(COACH LIGHTS)

(J BOX)

(4' FLUORESCENT)

(2' FLUORESCENT)

(5LT CHANDELIER)

(3 LT AVALON)

(PENDANT/ NOOK)

(X)

(X)

FOUNDATION STEEL 1 #4

(3) 3/0 W/ #6 GND. THWN CU

IN 2" CONDUIT

METER

2P-200A M.C.B.

22,000 A.I.C.

NEMZ-3R ENCL.

(3) 3/0 THWN CU

IN 2" CONDUIT

A/C DISC #1 2P 60/50

NEMA-3RK5-FUSES

A.H.U. 2P-60

AMP C.B.

(2) #6'S THWN

(1) #10 GND.

THWN CU 3/4" COND.

150A

BRKR

PANEL POOL PUMP 2P 30/30

NEMA-3R RK5-FUSES

#(2) #10 THWN

(1) #10 GND.

THWN CU 3/4" C

UNDERGROUND

SERVICE PROVIDED

BY LOCAL ELECT.

COMPANY (1) #4 CU GND. TO 5/8" DIA X 8'-0"

LONG METAL ROD AS PER 250-83C

& COLD WATER PIPE

NOTE: ALUMINUM WIRE

OF EQUAL AMPERAGE

MAY SUBSTITUTED

C.W.P.

1#4

F

F

M

ELECTRICAL RISER DIAGRAM150 AMP SERVICE RISER

ELECTRICAL OUTLETS PLACED IN FIRE RATED WALLS SHALL BE IN

CONFORMANCE WITH THE UNDERWRITERS LABORATORIES, INC.,

FIRE RESISTANCE DIRECTORY, CURRENT EDITION. THESE

REQUIREMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE

FOLLOWING SPECIFIC ITEMS:

A) INDIVIDUAL OUTLET/SWITCH BOXES SHALL OT EXCEED (16 )

SQUARE INCHES IN AREA.

B) AGGREGATE AREA OF OUTLET/SWITCH BOXES SHALL NOT

EXCEED (100) SQUARE INCHES WITHIN (100) SUARE FEET OF

WALL AREA.

C) OUTLET/SWITCH BOXES LOCATED ON OPPOSITE SIDE OF THE

SAME WALL SHALL BE SEPERATED BY A MINIMUM OF (24)

INCHES.

D) ALL OUTLET/SWITCH BOXES SHALL BE SECURELY ATTACHED

TO THE STUDS AND THE OPENING IN THE WALL BOARD FACING

SHALL BE CUT SO THAT THE CLEARANCE BETWEEN THE BOX

AND THE WALLBOARD DOES NOT EXCEED 1/8 INCH.

ELECTRICAL NOTES FOR FIRE RATED WALLS

AIR CONDITIONING COORDINATION REQUIRED.

PRIOR TO ORDERING ROOF TRUSSES, THE CONTRACTOR SHALL WORK WITH THE AIR CONDITIONING SUB CONTRACTOR TO DESIGN/PLAN AND LAYOUT THE LOCATION OF AIR

HANDLING EQUIPMENT, AIR DUCT SIZE AND LOCATION AND COORDINATE THAT DESIGN WITH THE TRUSSES FOR SPACE, CONNECTIVITY, AND POSITION REQUIREMENTS.

THE CONTRACTOR MUST ADVISE THE TRUSS COMPANY PRIOR TO ANY CONSTRUCTION OF TRUSSES OF THE AIR CONDITIONING/HANDLING EQUIPMENTS SIZES AND WEIGHT

AND DUCT LAYOUT CONCERNS OR REQUIREMENTS THAT MAY HAVE THE POTENTIAL TO CHANGE OR MODIFY THE TRUSSES TO ACCOMODATE THE SAME.

THE CONTRACTOR SHALL COORDINATE CONDENSATION DISCHARGE LINE LOCATION, AND ELECTRICAL SERVICE TO AIR EQUIPMENT, AND PROVIDE ANY LOCAL DISCONNECTS,

LIGHTS AND SERVICE PLATFORMS THAT MAY BE REQUIRED.

ELECTRIC METER

200 AMP PANEL

SD

SCD

SDSCD

SCDSD

A/C DISCONNECT

A/C DISCONNECT

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI @

42"

A.F.F.

GFI @ 42"

A.F.F.

STUB OUT FOR GARAGE

DOOR OPENER

DB

FAN W/

LIGHT FAN W/

LIGHT

FAN W/

LIGHT

FAN W/

LIGHT

FAN W/

LIGHT

ELECTRIC METER200 AMP PANEL

A/C DISCONNECT

A/C DISCONNECT

GFI

GFI

GFI

GFI

GFI

GFI

GFI

GFI @ 42"

A.F.F.

GFI @ 42"

A.F.F.

STUB OUT FOR GARAGE

DOOR OPENER

FAN W/

LIGHTFAN W/

LIGHT

FAN W/

LIGHT

FAN W/

LIGHT

FAN W/

LIGHT

SD

SCD

SDSCD

EXH.

FAN

EXH.

FAN

EXH.

FAN W/

LIGHT

EXH.

FAN W/

LIGHT

VP VP

SD SCD

ATTIC ACCESS ATTIC ACCESS

KEYLESS KEYLESS

AA

A A

AA

AA

AAAA

AA

A

A

AAA A

A

A

AA

A A

DD

D D

DD

C

C

C

CD D

KK

H H

VP VPB B

BB F

F

F

F

EE

OPT.

OPT. OPT.

OPT. OPT. OPT.

OPT.OPT.

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-5

ELECTRICAL

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

3/16" = 1'-0"

ELECTRICAL PLAN

Page 7: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

RESIDENTIAL SPECIFICATIONS

1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT

THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL

REPORT ALL DISCREPENCIES BETWEEN THE DRAWINGS AND EXISTING

CONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.

2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK

ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,

HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO

ATTACH AND ACCOMMODATE OTHER WORK.

3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED

TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR

SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT

DETAIL IS SHOWN.

4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE

FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000

PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO

THE DESIGNER PRIOR TO COMMENCING WORK.

5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUCTION WITH JOB

SPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL,

PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR

SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON

STRUCTURAL DRAWINGS.

6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE

ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERS

SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.

SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITY

AND EQUIVALENT STRENGTH PRODUCT.

ALL BOLTS, NUTS, WASHERS, STRAPS AND FASTENERS INCLUDING

NAILS, SHALL BE HOT MOPED DIPPED GALVANIZED OR STAINLESS STEEL

CONTINUOUS ANCHORAGE SHALL BE PROVIDED BETWEEN ALL TRUSSES,

WALL SECTIONS, BEAMS, POSTS AND FOOTINGS WITH USE OF STRAPS

AND CONNECTORS AS SPECIFIED HEREIN.

7. TREATED WOOD REQUIREMENTS:-

ALL TREATED WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,

OR NATURALLY RESISTANT TO DECAY.

ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, OR

PRESSURE TREATED.

8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER

THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILTY

TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF

THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE

NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.

9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.

SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5

10. LANAI CEILINGS & COVERED ENTRY CEILINGS

1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"

EXTERIOR GYP. BOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALL

SCREWS @ 6" O.C. EDGE AND FIELD.

GENERAL NOTES

1

ROOF SHEATHING

SHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.

INSTALL PANELS WITH LONG DIMENSION PLACED PERPENDICULAR TO TRUSSES.

A 1/8" SPACE BETWEEN ADJACENT SHEETS SHALL BE MAINTAINED . INSTALL "H"

CLIPS AT UNSUPPORTED PANEL EDGES. THE ROOF SHEATHING SHALL BE NAILED WITH

8d RING SHANK NAILS @ 4" O.C. EDGE AND 6" O.C. FIELD. ENSURE THAT ALL NAILS

PENETRATE THE TOP CHORD OF THE TRUSSES WITHOUT SPLITTING. RING SHANK NAILS

PER R803.2.3.1 - 0.113" NOMINAL SHANK DIAMETER, RING DIAMETER OF 0.012"

OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL

ROUND HEAD, 2" NAIL LENGTH.

FLASHING

FLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL 0.0179" THICK,

26 GAUGE AZ50 ALUM ZINC, OR GALVANIZED STEEL 0.0179" THICK, 26 GAUGE

ZINC COATED G90. FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIP

SYSTEM ROOF SHEATHING MANUFACTURES PUBLISHED REQUIREMENTS. ALL

FLASHING AND INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).

DRIP EDGE

DRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLES ROOFS,

LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A MINIMUM

OF 1/2" BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINMUM

OF 2". DRIP EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE SHALL

BE A MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE.

GENERAL ROOF ASSEMBLY

3

INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE

LAYER APPLICATION UNDER TILE ROOF.

THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLY

WITH THE PROVISIONS OF R905.3 F.B.C.

MARKING: EACH ROOF TILE SHALL HAVE A PERMANENT

MANUFACTURER'S IDENTIFICATION MARK.

APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTEN

APPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALL

INCLUDED BUT NOT BE LIMITED TO THE FOLLLOWING:

1. TILE PLACEMENT AND SPACING,

2. ATTACHMENT SYSTEM NECESSARY TO COMPLY

WITH CURRENT WIND CODE,

A. AMOUNT AND PLACEMENT OF MORTART

B. AMOUNT AND PLACEMENT OF ADHESIVE

C. TYPE, NUMBER, SIZE AND LENGTH OF FASTENERS AND CLIPS.

3. UNDERLAYMENT

4. SLOPE REQUIREMENT.

CLAY AND CONCRETE ROOF TILE SPECS

4

SHINGLES

15# FELT SHALL BE INSTALLED UNDER ASPHALT SHINGLES. ALL

ASPHALT SHINGLES SHALL HAVE SELD-SEALING STRIPS OR BE

INTERLOCKING AND COMPLY WITH ASTM D 225 OR D 3462, AND

SHALL BE SECURED TO THE ROOF WITH NO LESS THAN 6

FASTENERS PER SHINGLE STRIP, OR A MINIMUM OF 2 FASTENERS

PER SHNGLE TAB, AND SHALL IN NO CASSE BE FASTENED WITH

LESS FASTENERS THAN THAT REQUIRED BY THE MANUFACTURE.

INSTALLATION SHALL COMPLY WITH MANUFACTURES REQUIREMENTS

FOR INSTALLATION IN THE GIVEN FLORIDA WIND ZONE, AS

DETERMINED BY ASTM D 3161.

FASTENERS

FASTENERS FOR ASPHALT SHINGLES SHALL COMPLY WITH ASTM F

1667, AND SHALL BE MADE WITH GALVANIZED STEEL, STAINLESS

STEEL OR ALUMINUM WITH A MINIMUM SHANK SIZE OF 12 GAUGE

(0.105") WITH A MINIMUM 3/8" DIAMETER HEAD SHANK AND SHALL

BE A LENGTH TO PENTRATE THE SHEATHING

THE NAIL COMPONENT OF PLASTIC CAP NAILS SHALL MEET OR EXCEED

THE REQUIREMENTS OF ASTM A 641, CLASS 1, OR EQUAL, AND

SHALL BE CORROSION RESTITANT BY ELECTRO GALVANIZATION,

MECHANICAL GALVANIZATION, HOT DIPPED GALVANIZATION OR

SHALL BE MADE OF STAINLESS STEEL, NON-FERROUS METAL

ASPHALT SHINGLE ROOF SPEC'S

6

A.P.A. RATED STURDI-FLOOR, EXPOSURE 1, TONGUE & GROOVE EDGES

SPAN RATING 48/24 OR BETTER, GLUED AND NAILED

FLOOR SHEATHNG AT 2ND FLOOR

5

PRESSURE TREATED

WOOD BUCK PER

TABLE 2 ON A-6

SL. GL. DOOR TRACK SEE

ENGINEERING

FROM MANFG. FOR DETAILS OF

BUCK TO FRAMEBLOCK WALL

1/2" DRYWALL

CEMENT PLASTER

METAL SASH

PRECAST SILL

CEMENT PLASTERPRESSURE TREATED WOOD

BUCK PER TABLE 2 ON A-6.

MARBLE SILL

1/2" DRYWALL W/ 1"X2"

P.T. TO BLOCK

BLOCK WALL

1"X4" TRIM

GARAGE DOOR BUCK PER

DETAIL ON STRUCTURALCEMENT PLASTER

CEMENT PLASTER

BLOCK WALL

PRESS. TREATED WOOD BUCK

PER TABLE 2 ON A-6.

METAL THRESHOLD

CEMENT PLASTEREXTERIOR DOOR

NOTE: INSTALL 2" X4" PT WHEN

RMAX IS USED FOR INSULATION

1/2" DRYWALL W/ 1"X2"

P.T. TO BLOCK

BLOCK WALL

ROOF SHEATHING PER SCHEDULES

AND PER NOTES ON TABLE 3 ON A-6

ROOF FINISHING PER PLAN

WOOD TRUSSES @ 24" O.C. (TYPICAL)

DESIGNED BY DELEGATED TRUSS ENGINEER

STRAP AT TRUSS PER

ROOF FRAMING PLAN

FLASHING AND DRIP EDGE PER

NOTES IN TABLE 3 ON A-6

BEAM PER

FRAMING PLAN

CEILING ON LANAI PER NOTE

10 IN TABLE 1 ON A-6

BOND BEAMINSTALL BLOCKING @

16" O.C. TYPICAL

4" DIA. HOLE FOR

INSULATION INSPECTION

1/2" CDX PLY

2X4 BLK.

2" APART

A-34

1/4" X 3-3/4" TAPCON

16" O.C. TYPICAL

2X4 PT BUCK

PRECAST LINTEL

CONC. BLOCK WALL CONC. BLOCK WALL

SILL

WINDOW OR DOOR ARCH

SPACE FRAMING ABOVE

SPECIAL NOTE:FRAMING OF DECORATIVE ARCHES AT

WINDOW AND DOOR OPENINGS SHALL

COMPLY WITH THE FOLLOWING:

1 X 4 MIN. BLOCKING

ATTACH W/ (2) 8d NAILS

TYPICAL EACH END

4" DIA. HOLE FOR

INSULATION INSPECTION

ATTACH 1X4 OR 1X8 PT W/ (2)

8d NAILS STAGGERED 8" O.C.

FOR FRAME APPLICATIONS OR 1-1/2"

0.113" CASE HARDENED PNEUMATIC

DRIVEN NAILS STAGGERED @ 8" O.C.

15/32" C-D PLYWOOD,

BOTH SIDES. ATTACH

W/ 8d NAILS 6" O.C.

EDGE.

FILL IN FRAMING

CONC. FOOTING

SEE FOUNDATION PLAN

FOR SIZE AND

REINFORCING.

1/2" DRYWALL W/

TEXTURED WALLS

1X2 P.T. FURRING STRIPS @ 24"

O.C. W/ INSULATION (MIN. R4.1)

WOOD BASE

4" CONC. SLAB ON 6 MIL.

VISQUEEN VAPOR BARRIER ON

MECHANICALLY COMPACTED FILL

@ 95%.

DECO. CEMENT

FINISH PER ASTM C-926

SILL SET IN MORTAR

SEE ENERGY CODE FORMS FOR

INSULATION R-VALUES

1X4 P.T. STRIP

ROOF SHEATHING PER SCHEDULE

2/S-1. AND PER NOTES IN TABLE 3

ON A-6

WOOD TRUSSES @ 24" O.C. (TYPICAL.)

DESIGNED BY DELEGATED TRUSS

ENGINEER.

EMBEDDED STRAP AT EACH

TRUSS PER ROOF FRAMING PLAN.

FLASHING AND DRIP

EDGE PER NOTES IN

TABLE 2 ON A-6

2X6 MIN. SUB FASCIA

VENTED SOFFIT SHALL

MEET R703.1.2.1 SEE

TABLE 3 ON S-3

WINDOW, SEE SCHEDULE AND PLAN

DRYWALL CEILING PER

NOTE 9 IN TABLE 1 ON A-6

GRADE

TYPICAL WALL SECTION

TILE ROOF PER NOTE 6 ON A-6.

PROVIDE VENTILATION

PER R806.1 PRECAST LINTEL SEE FRAMING PLAN

WINDOW BUCKS SEE TABLE 2 ON A-6

1X4 P.T. BUCK W. BED OF

CONTINUOUS CAULK UNDER

8X8 CONTINUOUS BOND

BEAM W/ 1 #5, GROUT

SOLID

SLOPE TO EXTERIOR

PRECAST CONCRETE SILL

PROVIDE TERMITE

TREATMENT WITH "BORA

CARE".

D

W

12" M

IN.

4" M

IN.

R310.2.1 MINMUM OPENING AREA- ALL EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF

5.7 SQUARE FEET (0.530 m2).

EXCEPTION- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET

CLEAR OPENING OF 5 SQUARE FEET (0.465 m2).

R310.2.1 MINMUM OPENING HEIGHT- THE MINIMUM NET CLEAR OPENING

HEIGHT SHALL BE 24 INCHES (610mm).

R310.2.1 MINMUM OPENING WIDTH- THE MINIMUM NET CLEAR OPENING

WIDTH SHALL BE 20 INCHES (508mm).

R310.1.1 OPERATIONAL CONSTRAINTS- EMERGENCY ESCAPE AND RESCUE

OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM

WITHOUT THE USE OF KEYS OR TOOLS.

R310.2.3 WINDOW WELLS- THE MINIMUM HORIZONTAL AREA OF THE WINDOW

WELL SHALL BE 9 SQUARE FEET (0.84 m2), WITH A MINIMUM HORIZONTAL

PROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOW

WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE

FULLY OPENED.

MINIMUM EGRESS WINDOW DETAIL

1'-8" MIN.

2'-0

" M

IN.

3'-8

" M

AX.

FINISH FLOOR

5.7 SQ. FT.

CLEAR OPENING

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-6

SECTIONS

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

3/4" = 1'-0"

SL. GL. DR. JAM TO BLOCK DETAIL

3/4" = 1'-0"

WINDOW JAM TO BLOCK DETAIL

3/4" = 1'-0"

GARAGE DOOR JAM DETAIL

3/4" = 1'-0"

DOOR JAM TO BLOCK DETAIL

3/4" = 1'-0"

LANAI/ ENTRY ROOF ASSEMBLY

Page 8: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

WALL SHEATHING

WITH HOUSE WRAP

OR ZIP SYSTEM

WALL SHEATHING

PAPER BACK

METAL LATH

MID WALL

WEEP SCREED

OVER FELT STRIP

MASONRY NAIL

6" WIDE FELT

MASONRY WALL

WOOD FRAMING EITHER

FLOOR TRUSS OR GABLE

END TRUSS

FELT AND

WEEP SCREED

WO

OD F

RAM

EM

ASO

NRY W

ALL

CORNER OF

BUILDING

CORNER BEAD

MITER OUT CORNER

BEAD AT MID WALL

WEEP SCREED

CAULK CENTER JOINT

IN MID WALL WEEP

SCREED 2" IN EA.

DIRECTION AT CORNER

CORNER OF

BUILDING

FULLY EMBED BACK FACE

OF WEEP SCREED IN

CAULK. LET OOZE OUT AT

CORNER AND SCREED 2"

MIN. WIDTH

WIRE LATH

WITH FELT

OVER FRAME

WALL

EXPANSION JOINT

EXPANSION JOINT OVER

WIRE LATH

DECO. TEXTURE FINISH

OVER WIRE LATH

WO

OD F

RAM

EM

ASO

NRY W

ALL

MASONRY WALLMASONRY WALL

DECO. TEXTURE FINISH

OVER WIRE LATH

EXPANSION JOINT

MASONRY WALL

EXPANSION JOINT

AMICO M-TYPE

CONTROL JOINT

AMCJM-780 OR

APPROVED EQUAL

OVER LATH (CUT

LATH BEHIND

CONTROL JOINT 1/4"

MIN. GAP) LOCATE

OVER STUD ONLY

AND PER NOTE 1

*

*NOTE 1:(AT WOOD

FRAME ONLY)

MAX OF 144 SQ. FT.

BETWEEN CONTROL

JOINTS. NOT GREATER

THAN 18'-0" O.C. MAX

AREA RATIO OF

CONTROL JOINTS-2-2/1 TO 1

WIRE THE CONTROL

JOINT TO LATH WITH

18 GA. GALVANIZED

WIRE AT 7' O.C. MAX.

WIRE LATH

OVER FELT

FELT PAPER

FRAME WALL

FELT STRIP

WIRE LATH OVER

MID WALL

WEEP SCREED

OVER FELT STRIPMID WALL

WEEP SCREED

OVER FELT STRIP

MITER OVER SCREED

FELT STRIP

OVER BLOCK WALL

BUILDING

MASONRY WALL

MID WALL WEEP SCREED DETAIL

WEEP SCREED DETAILINSTALL AT ALL EXTERIOR WALL LOCATIONS WHERE

WOOD STUD FRAMING IS ABOVE MASONRY WALLS.

GABLE WALL ROOF

EXTERIOR

ATTICATTICEXTERIOR

HOUSE WRAP

EXTERIOR PLYWOOD W/

RADIANT BARRIER ON

ATTIC SIDE

EXTERIOR STUD

WALL OR TRUSS

RADIANT BARRIER

GLUED TO PLYWOOD

TOP CHORD

RADIANT BARRIER: SCALE: N.T.S.

NOTE: EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVE

RADIANT BARRIER AND HOUSE WRAP.

R703.4 - WHERE FLASHING INSTRUCTIONS OR DETAILS ARE NOT PROVIDED BY THE WINDOW

OR DOOR MANUFACTURER OR BY THE FLASHING MANUFACTURER, "PAN FLASHING" AHLL BE

INSTALLED AT THE SILL OF EXTERIOR WINDOW AND DOOR OPENINGS. PAN FLASHING SHALL

BE SEALED OR SLOPED IN SUCH A MANNER AS TO DIRECT WATER TO THE SURFACE OF THE

EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR SUBSEQUENT DRAINAGE.

OPENINGS USING PAN FLASHING SHALL ALSO INCORPORATE FLASHING OF PROTECTION AT

THE HEAD AND SIDES.

"PAN FLASHING" IS A GENERIC TERM THAT USED TO REFER TO "METAL PAN FLASHING".

HOWEVER MANY MODERN MATERIALS HAVE BEEN DEVELOPED FOR THE SAME FUNCTION

SUCH AS:

- FLEXIBLE PEEL AND STICK FLASHING MEMBRANE

-FLUID APPLIED FLASHING

FOR SUCH PRODUCTS FOLLOW THE MANUFACTURER'S INSTALLATION REQUIREMENTS

FOR IN-DEPTH FLASHING INSTRUCTIONS, REFER TO THE FOLLOWING PUBLICATIONS:

FMA/AAMA 100

FMA/AAMA 200

FMA/WDMA 250

FMA/AAMA/WDMA 300

INSTALL "PAN" FLASHING AT THE WINDOW SILL

OPENING FOR WINDOW OR DOOR

WHERE "PAN" FLASHING IS

USED AT THE SILL, ALSO

INCORPORATE FLASHING

OR PROTECTION AT THE

HEAD AND SIDES

THE FLASHING INSTRUCTIONS FROM THE WINDOW/ DOOR MFR., OR THE FLASHING MFR.,

SHALL SUPERCEDE THIS DETAIL

PAN FLASHING PER R703.4

SCALE: N.T.S.

SCALE:

DATE:

DRAWN BY:

CHECKED BY:

PLAN:

REVISED:

DESIGN IN ACCORDANCE WITH THE RESIDENTIAL

FLORIDA BUILDING CODE 2017 - 6TH EDITION

As indicated

K:\1-M

ASTER 2

019\2

019-B

UIL

DERS\D

R H

ORTO

N 2

019\S

UBD

IVIS

IONS\L

IND

SFO

RD

II

TV'S

\11270 L

OT 0

312-0

313 1

526 A

R\R

EVIT

\11270 1

526 A

R.r

vt

A-7

BANDING DETAILS

15

26 V

ILLA

MO

DEL

JWC

JSL

10/17/19

LOT:

03

12

-031

3

SUBD

IVIS

ION:

LIND

SFO

RD

II TVs

AD

DRS:

44

71

-44

67

DUTC

HESS P

ARK R

D

D.R

.H.

#:

578

91

01

59

-160

GC

D J

OB #

11

270

Page 9: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4

” ”

AutoCAD SHX Text
2
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
1
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES: 1) PROVIDE SAWCUTS TO CREATE APPROXIMATE 20' X 20' MAXIMUM SQUARES. 2) SAWCUT CONCRETE SLAB WITHIN 4 TO 12 HOURS OF CONCRETE PLACEMENT.
AutoCAD SHX Text
~w" DEEP SAWCUT w/ ELASTOMERIC SEALANT
AutoCAD SHX Text
SLAB ON GRADE, SEE PLAN
AutoCAD SHX Text
%%USLAB SAWCUT DETAIL
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
11
AutoCAD SHX Text
%%UCORNER BARS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%USTEP FOOTING
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
3" CLEAR COVER TO REINFORCING
AutoCAD SHX Text
EMBED DOWELS 5" WITH 10" STD HOOK
AutoCAD SHX Text
MONOLITHIC FOOTING, SEE PLAN
AutoCAD SHX Text
DOWEL TO MATCH WALL REINFORCING, LAP 25"
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
%%UMONOLITHIC FOOTINGS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%UINTERIOR
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
%%UEDGE
AutoCAD SHX Text
%%UGARAGE
AutoCAD SHX Text
D
AutoCAD SHX Text
%%USTEPDOWN
AutoCAD SHX Text
C
AutoCAD SHX Text
9
AutoCAD SHX Text
3" COVER
AutoCAD SHX Text
MAINTAIN FOOTING WIDTH & DEPTH AT ALL VERT. AND HORIZ. SEGMENTS
AutoCAD SHX Text
FOOTING REINF., SEE PLAN. LAP 40 BAR DIAMETERS
AutoCAD SHX Text
MAINTAIN RUN TO RISE OF 2:1 OR MORE
AutoCAD SHX Text
%%UFOOTING
AutoCAD SHX Text
%%UPLAN VIEW
AutoCAD SHX Text
FOOTING REINF., SEE PLAN
AutoCAD SHX Text
LAP CORNER BARS 40 BAR DIAMETERS
AutoCAD SHX Text
CONCRETE FOOTING, SEE PLAN
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%UROOF DECK NAILING PATTERN
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
8d RING SHANK NAILS 6" O.C. EDGE AND 6" OC FIELD. ENSURE THAT ALL NAILS PENETRATE THE TOP CHORD OF THE TRUSS WITHOUT SPLITTING.
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UCORNER
AutoCAD SHX Text
%%UCORNER BAR DETAIL IN BOND BEAMS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UINTERSECTION
AutoCAD SHX Text
%%UBOND BEAM REINFORCING DETAIL
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
8"x8" BOND BEAM w/ 1-#5
AutoCAD SHX Text
TRUSS BEARING
AutoCAD SHX Text
#5 VERTICAL IN GROUTED CELL AT DOT LOCATIONS ON PLAN
AutoCAD SHX Text
7" STANDARD HOOK INTO TOP OF BOND BEAM (MAY USE 7"x25" BENT BAR)
AutoCAD SHX Text
LINTEL AT LANAI OR ENTRY, '8F16-1B/1T' (8"x16" FILLED SOLID, 1#5 BOTTOM, 1-#5 TOP)
AutoCAD SHX Text
#5 VERT. AT INTERSECTION OF BOND BEAM w/ 7" HOOK AT TOP
AutoCAD SHX Text
DESIGN CRITERIA: DESIGN IN ACCORDANCE WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 6TH EDITION (2017) RESIDENTIAL 1. FLOOR & ROOF UNIFORM LOADS: ELEVATED FLOORS: LIVE LOAD 40 PSF, DEAD LOAD 20 PSF ROOF: LIVE TOP CHORD 20 PSF LIVE BOTTOM CHORD 10 PSF (NON-CONCURRENT w/ TCLL) CEMENT ROOF TILE DEAD LOAD 25 PSF TOTAL SHINGLE/METAL ROOFING DEAD LOAD 15 PSF TOTAL MINIMUM DEAD LOAD FOR WIND: TC 5 PSF, BC 5 PSF DEFLECTION CRITERIA: FLOOR L/480 LIVE, L/360 TOTAL ROOF L/240 LIVE, L/180 TOTAL 2. WIND LOADS: WIND DESIGN PER ASCE7-10 BASIC WIND SPEED (ASCE7-10) 160 MPH NOMINAL WIND SPEED (Vasd TABLE R301.2.1.3) 124 MPH BUILDING CATEGORY II IMPORTANCE FACTOR 1.00 EXPOSURE C MEAN ROOF HEIGHT = 15 FT ROOF PITCH 5/12 ENCLOSURE CLASS. ENCLOSED INTERNAL PRES. COEFF. +/- 0.18 WINDOW/DOOR DESIGN WIND PRESSURE, SEE TABLE IN DETAIL 3. SOFFITS - PER R703.1.2.1, ALL SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED IN TABLE R301.2(2) FOR WALLS. 3. REINFORCED CONCRETE: DESIGN AS PER ACI 318-14 REQUIRED COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON GRADE f'c = 2500 PSI 3~8" MINIMUM THICKNESS REINFORCED WITH 6x6 w1.4xw1.4 WWF OR FIBERMESH. CONVENTIONAL SHALLOW FOOTINGS f'c = 2500 PSI BEAMS AND COLUMNS f'c = 3000 PSI ALL OTHER CONCRETE (U.N.O.) f'c = 3000 PSI UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE AS FOLLOWS: FOOTINGS 3" SLAB ON GRADE CENTERED BEAMS 1~8" COLUMNS 1~8" ALL REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAMS AND PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. ALL REINFORCING STEEL SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. REINFORCING STEEL - ASTM A615 GRADE 40 FOR #3 GRADE 60 FOR #4 TO #11 WELDED WIRE FABRIC - ASTM A185 SPLICES IN REINFORCING, SHALL BE 40 BAR DIAMETERS. NON-CONTACT LAP SPLICES MAY BE USED PROVIDED REINFORCING IS NOT SPACED MORE THAN 5" APART FOR #5 BARS. FORMWORK AND SHORING SHALL REMAIN IN PLACE UNTIL CONCRETE HAS REACHED AT LEAST 2/3 OF THE REQUIRED 28 DAY STRENGTH. 4. REINFORCED MASONRY: DESIGN PER ACI 530-13 REQUIRED COMPRESSIVE STRENGTHS: MASONRY WALLS f'm = 1500 PSI REINFORCING STEEL - ASTM A615 GRADE 60. SPLICES IN REINFORCING, SHALL BE 48 BAR DIAMETERS. ALL CONCRETE MASONRY UNITS SHALL BE COMPOSED OF ASTM C90, GRADE N-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH 3000 PSI PEA ROCK CONCRETE GROUT. ALL CELLS BELOW FINISHED GRADE SHALL BE GROUTED SOLID. ALL EXTERIOR WALLS SHALL BE REINFORCED FULL HEIGHT AT DOT LOCATIONS ON PLAN. 5. DELEGATED-ENGINEERED WOOD ROOF & FLOOR TRUSSES: ALL WOOD ROOF AND FLOOR TRUSSES SHALL BE DESIGNED BY A DELEGATED TRUSS ENGINEER PER RULE 61G15-31.003 OF THE FLORIDA ADMINISTRATIVE CODE. ALL TRUSSES SHALL HAVE TEMPORARY BRACING PER "COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES, HIB-91." FOR OTHER BRACING REQUIREMENTS, NOTIFY ENGINEER. PROVIDE PERMANENT BRACING PER TRUSS MFR. SHOP DRAWINGS. IF PERMANENT BRACING IS NOT SPECIFIED, CONTACT ENGINEER. 6. FOUNDATION: CONVENTIONAL SHALLOW CONCRETE FOOTINGS SOIL BEARING CAPACITY 2000 PSF THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL CONDITIONS FOR THE INTENDED STRUCTURE AND ASSUMED SOIL BEARING CAPACITY. IT IS RECOMMENDED THAT A GEOTECHNICAL FIRM BE HIRED TO PERFORM A SITE EVALUATION. 7. DIMENSIONS: VERIFY ALL DIMENSIONS WITH HOUSE PLANS. SEE HOUSE PLANS, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES, ETC. WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS. 8. MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO SUPPORT STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE OF ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 9. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE PREPARED AND SUBMITTED TO THE ENGINEER FOR REVIEW FOR ALL STRUCTURAL ELEMENTS UTILIZING PREFABRICATED COMPONENTS. ONE SET OF SIGNED & SEALED TRUSS ENGINEERING SHALL BE DELIVERED TO THE ENGINEER OF RECORD FOR THE STRUCTURE PER FLORIDA ADMINISTRATIVE CODE 61G15-30.005 AND 61G15-31.003.
AutoCAD SHX Text
8" CMU, SEE PLAN FOR REINFORCING
AutoCAD SHX Text
NOTE: THIS BUCK FASTENING DETAIL IS INTENDED FOR FLANGED WINDOW/DOOR PRODUCTS THAT FASTEN THRU THE FLANGE WITH WOOD SCREWS TO THE BUCK. FOR WINDOW/DOOR PRODUCTS THAT DO NOT HAVE A FLANGE AND FASTEN INSTEAD OUTWARD THRU THE FRAME, USE MASONRY SCREWS PER MFR. THAT ARE LONG ENOUGH TO PENETRATE 2-1/4" INTO THE MASONRY. IN THIS CASE, THE BUCK MATERIAL IS SIMPLY A SPACER AND MAY BE 1x4 OR 1x6 OR OMITTED ENTIRELY AND THE SPACER MAY BE TACKED IN PLACE WITH MASONRY NAILS OR PINS.
AutoCAD SHX Text
%%UBUCK FASTENING
AutoCAD SHX Text
~4"x3~w" TAPCON @ 24" OC, 3 SCREWS MIN. (SEE NOTE)
AutoCAD SHX Text
2x4 or 2x6 P.T. BUCK @ FLANGED WINDOWS (SEE NOTE)
AutoCAD SHX Text
8" CMU WALLS
AutoCAD SHX Text
~8"~D EXPANSION BOLT, 4" MIN. EMBEDMENT, SPACE 24" OC AND 12" FROM TOP & BOT.
AutoCAD SHX Text
%%UGARAGE DOOR
AutoCAD SHX Text
2x8 OR 2x6 P.T. SYP#2
AutoCAD SHX Text
2x2x~2" WASHER
AutoCAD SHX Text
APPROVED ISOLATION PLATE
AutoCAD SHX Text
8"x8" CONTINUOUS MASONRY BOND BEAM w/ 1-#5, GROUT SOLID. PROVIDE CORNER BARS PER DETAIL 6/S-1
AutoCAD SHX Text
#5 VERT. IN GROUTED CELL AT DOT LOCATIONS ON PLAN (48" OC MAX EXTERIOR)
AutoCAD SHX Text
12
AutoCAD SHX Text
EMBEDDED STRAP AT EACH ROOF TRUSS, SEE ROOF PLAN. BREAK OUT WEB OF BLOCK AS NEEDED TO PROPERLY LOCATE EACH STRAP
AutoCAD SHX Text
#5 VERTICAL SHALL HAVE 7" STANDARD HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
%%UTRUSS STRAP TO BOND BEAM
AutoCAD SHX Text
WOOD TRUSSES @ 24" OC, DESIGNED BY DELEGATED TRUSS ENGINEER
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE 2/S-1
AutoCAD SHX Text
5
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
TRUSS BEARING
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
SOFFITS SHALL MEET WIND DESIGN PRESSURES PER R703.1.2.1. FOR FIELD FRAMING, SEE TABLE 2/S-1
AutoCAD SHX Text
5
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
(Vasd=124 MPH, RISK CAT II, ENCLOSED, kd=0.85, h=15')
AutoCAD SHX Text
INTERIOR ZONE 4
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
(SEE PLAN FOR OTHER SPECIFIC PRESSURES)
AutoCAD SHX Text
1) TABLE MAY BE USED FOR ANY SIZE WINDOW OR DOOR IN EACH TYPE. 2) USE "INTERIOR ZONE 4" PRESSURES UNLESS WINDOW OR DOOR IS LOCATED WITHIN THE "END ZONE 5" (SEE DIAGRAM BELOW), THEN USE THE HIGHER PRESSURES UNDER THE "END ZONE 5" COLUMN. 3) ALL GLASS / GLAZING SHALL BE IMPACT RATED OR USE IMPACT RATED SHUTTERS. 4) SUBMIT PRODUCT APPROVALS TO THE BUILDING DEPARTMENT AS REQUIRED BY THE LOCAL JURISDICTION. 5) MANUFACTURED SOFFIT PRODUCTS SHALL BE INSTALLED PER MFR ENGINEERING SPEC SHEETS.
AutoCAD SHX Text
WINDOW/DOOR/SOFFIT DESIGN WIND PRESSURES
AutoCAD SHX Text
TO ALLOWABLE STRESS DESIGN PRESSURES USING 0.6W LOAD FACTOR.
AutoCAD SHX Text
WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND CONVERTED
AutoCAD SHX Text
* ON IRREGULAR SHAPED BUILDINGS, THERE IS NO GUIDANCE IN THE CODE FOR HOW FAR A CORNER MUST PROTRUDE FROM THE MAIN BUILDING TO BE CONSIDERED 'ZONE 5'. WE HAVE CHOSEN >15'. THIS IS SUBJECT TO JUDGEMENT CALL BY THE AUTHORITY HAVING JURISDICTION.
AutoCAD SHX Text
IN ZONE 5, MANUFACTURED SOFFIT PRODUCTS MAY REQUIRE ADDITIONAL BATTONS OR FASTENING PER MFR ENGINEERING SPEC SHEETS TO MEET THE PRESSURE REQUIREMENTS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
8' OR 9' GARAGE DOORS
AutoCAD SHX Text
TYPICAL WINDOWS & DOORS
AutoCAD SHX Text
16' OR 18' GARAGE DOORS
AutoCAD SHX Text
SOFFIT
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
END ZONE 5 PRESSURES OCCUR AT "PRIMARY" OUTSIDE CORNERS OF BUILDING (BOLD LINES)
AutoCAD SHX Text
FACE OF WALL
AutoCAD SHX Text
MEASURED FROM
AutoCAD SHX Text
ZONE
AutoCAD SHX Text
4
AutoCAD SHX Text
INTERIOR ZONE 4 PRESSURES
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
5'-0"
AutoCAD SHX Text
WIDTH = ______
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
END ZONE 5
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
+29.4 -33.3
AutoCAD SHX Text
+28.2 -31.5
AutoCAD SHX Text
END
AutoCAD SHX Text
10
AutoCAD SHX Text
%%URETROFIT UPLIFT CONNECTOR SCHEDULE
AutoCAD SHX Text
SHEATHING SCHEDULE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
N/A
AutoCAD SHX Text
EXTERIOR STUD WALL
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
EXTERIOR CEILING AND SOFFIT
AutoCAD SHX Text
OPTIONS: 1) 1x4 STRIPPING @ 16"OC w/ 2-8d NAILS TO EACH TRUSS, ~0" EXTERIOR GYPBOARD CEILING, FASTEN w/8d NAILS OR 1~0" DRYWALL SCREWS @ 6"OC EDGE & FIELD. 2) ~6" BC PLYWOOD NAILED w/ 6d COMMON @ 6" OC EDGE & FIELD. 3) VINYL OR ALUMINUM PERFORATED SOFFIT INSTALLED PER MANUFACTURER INSTRUCTIONS TO MEET WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
A.P.A. RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER. FASTEN WITH 8d RING SHANK NAILS @ 6" O.C. EDGE AND 6" O.C. FIELD.
AutoCAD SHX Text
(RING SHANK NAILS PER R803.2.3.1: 0.113" NOMINAL SHANK DIAMETER, RING DIA. OF 0.012" OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL ROUND HEAD, 2" NAIL LENGTH)
AutoCAD SHX Text
NOTE: EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED : EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED HERE MEET THE DESIGN WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
7/16" ZIP SYSTEM WALL SHEATHING BY HUBER ENGINEERED WOODS LLC, NAILED W/ 8d COMMON WIRE @ 6" O.C. EDGE AND 6" O.C. FIELD. PROVIDE 2x4 BLOCKING AT ALL JOINTS. INSTALL SHEATHING AND SEAM TAPE IN STRICT ACCORDANCE WITH MFR. WRITTEN INSTRUCTIONS.
AutoCAD SHX Text
(WHEN ~8" ZIP BRAND ROOF SHEATHING IS USED, H-CLIPS ARE NOT REQUIRED) REQUIRED)
AutoCAD SHX Text
NOTES: 1) WHERE EMBEDDED STRAP IS MISSING OR MIS-LOCATED, PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE. 2) CONNECTORS ARE USP. ALL CONNECTORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH USP PRINTED INSTRUCTIONS. 3) CONCRETE SCREW SHALL BE WEDGE-BOLT+, TITEN, TAPCON OR EQUIVALENT.
AutoCAD SHX Text
1-HTWM16 or 20
AutoCAD SHX Text
2-LUGT2
AutoCAD SHX Text
HGT-2/3
AutoCAD SHX Text
2-HTWM16 or 20
AutoCAD SHX Text
CONNECTOR
AutoCAD SHX Text
1-HTWM16 or 20
AutoCAD SHX Text
RETROFIT STRAPS TO CONCRETE/MASONRY
AutoCAD SHX Text
TO 9790
AutoCAD SHX Text
TRUSS UPLIFT (LBS)
AutoCAD SHX Text
TO 1145
AutoCAD SHX Text
TO 4520
AutoCAD SHX Text
TO 2290
AutoCAD SHX Text
TO 3610
AutoCAD SHX Text
TO 1145
AutoCAD SHX Text
@ 24" OC
AutoCAD SHX Text
HTT16
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
EPOXY 12" EMBED WITH USP SET.
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 CONCRETE SCREW
AutoCAD SHX Text
16-16d, 7-~4"x2~4" CONCRETE SCREW
AutoCAD SHX Text
18-10d, ~0"~D ALLTHREAD, DRILL
AutoCAD SHX Text
& EPOXY 10" EMBED w/ USP SET.
AutoCAD SHX Text
TWO ~w"~D ALTHREAD, DRILL &
AutoCAD SHX Text
%%UOUTLOOKER DETAIL
AutoCAD SHX Text
12
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%UOUTLOOKER DETAIL
AutoCAD SHX Text
SCALE: N.T.S.
AutoCAD SHX Text
13
AutoCAD SHX Text
2x4 OUTLOOKER @ 24" O.C.
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE
AutoCAD SHX Text
2x4 TOP CHORD
AutoCAD SHX Text
TRUSS B10
AutoCAD SHX Text
GABLE END TRUSS GE11
AutoCAD SHX Text
At Exterior Stud Walls and Gable Ends with Wall Sheathing, apply plaster over metal lath over water resistive barrier as follows: Plaster R703.7.2: 3-coat 7/8" thick : 3-coat 7/8" thick thick portland cement based plaster per ASTM C926. Metal Lath R703.7.1: Self furring paper : Self furring paper backed 2.5lb diamond mesh metal lath per ASTM C847, G60 galvanized, fastened per ASTM C1063 with 1-1/2” long, 11 long, 11 gage nails with 7/16” head (roofing nails) head (roofing nails) at 7” oc, or 1-1/2” long, 16 gage staples oc, or 1-1/2” long, 16 gage staples long, 16 gage staples at 6” oc, into the framing members (ie, oc, into the framing members (ie, the nails or staples must align with and penetrate 3/4” into the framing studs). into the framing studs). Water Resistive Barrier (WRB) R703.7.3: : Water-resistive vapor-permeable barrier with a performance at least equivalent to 2 layers of Grade D paper. The individual layers shall be installed independently. An approved house wrap may be used for the 1st layer and metal lath with approved paper backing may be the 2nd layer (Note: ZIP wall sheathing with seam tape qualifies as the first layer).
AutoCAD SHX Text
ROOF COVERING AS SELECTED BY BUILDER PER: FBCR905.2 ASPHALT SHINGLES FBCR905.3 CLAY AND CONCRETE TILE FBCR 905.4 METAL ROOF
AutoCAD SHX Text
2x4 BLOCKING FOR BOTH EDGES OF SHEATHING
AutoCAD SHX Text
B TRUSSES
AutoCAD SHX Text
ROOF SHEATHING PER SCHEDULE 2/S-3
AutoCAD SHX Text
ROOF SHEATHING PER SCHEDULE 2/S-3
AutoCAD SHX Text
2x4 BLOCKING FOR EDGE OF SHEATHING
AutoCAD SHX Text
DO NOT BLOCK AIR FLOW FROM SOFFIT
AutoCAD SHX Text
GABLE END BRACING NOT REQUIRED
AutoCAD SHX Text
1-HTA16-18, TYPICAL
AutoCAD SHX Text
2-16d TOENAILS FROM TRUSS CHORD TO TOP & BOTTOM OF GABLE END
AutoCAD SHX Text
GABLE END BRACING NOT REQUIRED
AutoCAD SHX Text
9'-4"
AutoCAD SHX Text
9'-4"
AutoCAD SHX Text
S-1
AutoCAD SHX Text
1
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DWB/DWB
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/15/19
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DR11270
AutoCAD SHX Text
3
AutoCAD SHX Text
FOR SCOSTA TRUSSES, JOB # 44151GB, DATED 06/18/19, REVISED: 09/30/19
AutoCAD SHX Text
1526 SIGNATURE VILLA
AutoCAD SHX Text
STRUCTURAL DETAILS FOR
AutoCAD SHX Text
4467, 4471 DUTCHESS PARK ROAD FORT MYERS, FLORIDA LOTS: 312, 313 SUBDIVISION: LINDSFORD II
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
Page 10: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4
AutoCAD SHX Text
CONCRETE RAKE BEAM w/ 1#5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
ROOF SHEATHING, FIRE RETARDANT TREATED PLYWOOD, 4'-0" EACH SIDE OF WALL
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
1B
AutoCAD SHX Text
%%UTOP OF FIREWALL
AutoCAD SHX Text
FILL AIR GAP WITH "Thermafiber brand FireSpan insulation", OR EQUIVALENT
AutoCAD SHX Text
2x6 PT BLOCKING AGAINST ROOF SHEATHING
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
FIRE CAULK
AutoCAD SHX Text
2 HOUR FIRE RATED BLOCK WALL
AutoCAD SHX Text
CONCRETE RAKE BEAM w/ 1#5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
ROOF TRUSS
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
1A
AutoCAD SHX Text
%%UTOP OF FIREWALL
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
2 HOUR FIRE RATED BLOCK WALL
AutoCAD SHX Text
RAKE BEAM AT TOP OF FIREWALL HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
BLOCKING AT UNDERSIDE OF ROOF SHEATHING FILL AIR GAP WITH THERMAFIBER FIRESPAN INSULATION (OR EQUIVALENT).
AutoCAD SHX Text
CONCRETE RAKE BEAM w/ 1#5
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
2B
AutoCAD SHX Text
%%UTOP OF FIREWALL
AutoCAD SHX Text
2x6 PT BLOCKING AGAINST ROOF SHEATHING
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
FIRE CAULK
AutoCAD SHX Text
2 HOUR FIRE RATED BLOCK WALL
AutoCAD SHX Text
CONCRETE RAKE BEAM w/ 1#5
AutoCAD SHX Text
ROOF TRUSS
AutoCAD SHX Text
SCALE: 1-1/2" = 1'-0"
AutoCAD SHX Text
2A
AutoCAD SHX Text
%%UTOP OF FIREWALL
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
2 HOUR FIRE RATED BLOCK WALL
AutoCAD SHX Text
ROOF SHEATHING, FIRE RETARDANT TREATED PLYWOOD, 4'-0" EACH SIDE OF WALL
AutoCAD SHX Text
%%USLOPED TRUSSES
AutoCAD SHX Text
%%UFLAT TRUSSES
AutoCAD SHX Text
1-1/2" PLUS OR MINUS 1/2"
AutoCAD SHX Text
1-1/2" PLUS OR MINUS 1/2"
AutoCAD SHX Text
RAKE BEAM AT TOP OF FIREWALL HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
BLOCKING AT UNDERSIDE OF ROOF SHEATHING FILL AIR GAP WITH THERMAFIBER FIRESPAN INSULATION (OR EQUIVALENT).
AutoCAD SHX Text
FILL AIR GAP WITH "Thermafiber brand FireSpan insulation", OR EQUIVALENT
AutoCAD SHX Text
PROVIDE UL301 DETAIL WITHIN OVERHANG
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
9'-4"
AutoCAD SHX Text
%%UFOR 5:12 ROOF PITCH
AutoCAD SHX Text
%%USECTION FOR 1526 VILLA
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
8x8 BOND BEAM w/ 1#5
AutoCAD SHX Text
PROVIDE UL301 DETAIL WITHIN OVERHANG
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
TRUSS GE11
AutoCAD SHX Text
PROVIDE UL301 DETAIL WITHIN VALLEY
AutoCAD SHX Text
6
AutoCAD SHX Text
TRUSS B7
AutoCAD SHX Text
TRUSS B6
AutoCAD SHX Text
2 HOUR FIREWALL USING 2 HOUR FIRE RATED 8" MASONRY PER FBC721 "PRESCRIPTIVE FIRE RESISTANCE". SEE TABLE ON A-4.
AutoCAD SHX Text
5'-0" OFFSET CONTROL LINE USED BY SHELL CONTRACTOR
AutoCAD SHX Text
PROVIDE UL301 DETAIL WITHIN OVERHANG
AutoCAD SHX Text
AIR GAP TO ROOF SHEATHING
AutoCAD SHX Text
TRUSS A13
AutoCAD SHX Text
TRUSS A3
AutoCAD SHX Text
TRUSS A10
AutoCAD SHX Text
TRUSS A20
AutoCAD SHX Text
TOP EDGE OF ROOF TRUSSES
AutoCAD SHX Text
AIR GAP TO ROOF SHEATHING
AutoCAD SHX Text
AIR GAP TO TO ROOF SHEATHING
AutoCAD SHX Text
TRUSS A10
AutoCAD SHX Text
PROVIDE UL301 DETAIL WITHIN OVERHANG
AutoCAD SHX Text
#5 VERTICAL IN GROUTED CELL @ 7'-4" O.C. AT INTERIOR
AutoCAD SHX Text
S-2
AutoCAD SHX Text
2
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DWB/DWB
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/15/19
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DR11270
AutoCAD SHX Text
3
AutoCAD SHX Text
FOR SCOSTA TRUSSES, JOB # 44151GB, DATED 06/18/19, REVISED: 09/30/19
AutoCAD SHX Text
1526 SIGNATURE VILLA
AutoCAD SHX Text
STRUCTURAL DETAILS FOR
AutoCAD SHX Text
4467, 4471 DUTCHESS PARK ROAD FORT MYERS, FLORIDA LOTS: 312, 313 SUBDIVISION: LINDSFORD II
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
Page 11: A-1...F3 F3 F3 F3 F3 F3 F6A F3 W/ CURB F5 W/ CURB F6 F3 F3 F3 F3 F3 W/ CURB F6A F6 F3 F3 F3 F3 F3 F3 F3 F3 F5 F5 F A SINK & DISP. SINK & DISP. 5'-0" TUB W W 5'-0" TUB C 6'-6 1/2" 2'-4
AutoCAD SHX Text
8" MASONRY
AutoCAD SHX Text
2x4 PT LEDGER
AutoCAD SHX Text
FOOTING AS NOTED ON FOUNDATION PLAN
AutoCAD SHX Text
#5 IN GROUTED CELL @ 7'-4" O.C. AT INTERIOR (48" O.C. EXTERIOR)
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%U2 HOUR FIREWALL AT GARAGE
AutoCAD SHX Text
#5 DOWEL @ 7'-4" O.C., LAP 25"
AutoCAD SHX Text
4" CONCRETE SLAB
AutoCAD SHX Text
DRYWALL CEILING
AutoCAD SHX Text
ROOF TRUSSES @ 24" O.C., RUN PARALLEL TO FIREWALL. NO BEARING ON FIREWALL
AutoCAD SHX Text
#5 IN GROUTED CELL @ 7'-4" O.C. AT INTERIOR (48" O.C. EXTERIOR)
AutoCAD SHX Text
CONCRETE RAKE BEAM, 8" MINIMUM DEPTH w/ 1#5 CONTINUOUS
AutoCAD SHX Text
NO PENETRATIONS IN FIREWALL
AutoCAD SHX Text
8" MASONRY
AutoCAD SHX Text
FOOTING AS NOTED ON FOUNDATION PLAN
AutoCAD SHX Text
#5 IN GROUTED CELL @ 7'-4" O.C. AT INTERIOR (48" O.C. EXTERIOR)
AutoCAD SHX Text
2
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%U2 HOUR FIREWALL AT LIVING AREA
AutoCAD SHX Text
#5 DOWEL @ 7'-4" O.C., LAP 25"
AutoCAD SHX Text
4" CONCRETE SLAB
AutoCAD SHX Text
DRYWALL CEILING
AutoCAD SHX Text
ROOF TRUSSES @ 24" O.C.
AutoCAD SHX Text
TRUSS PROFILES VARY, SEE PLAN
AutoCAD SHX Text
8" MASONRY BOND BEAM w/ 1#5
AutoCAD SHX Text
CONCRETE RAKE BEAM, 8" MINIMUM DEPTH w/ 1#5 CONTINUOUS
AutoCAD SHX Text
NO PENETRATIONS IN FIREWALL
AutoCAD SHX Text
BLOCKING AT MID HEIGHT
AutoCAD SHX Text
DOUBLE TOP PLATE w/ SPTH4 OR SPTH6 @ 16" O.C.
AutoCAD SHX Text
2x4 OR 2x6 SPF #2 @ 16" O.C.
AutoCAD SHX Text
MTW16 STRAP
AutoCAD SHX Text
2x4 OR 2x6 PT SILL PLATE w/ SPTH4 OR SPTH6 @ 16" O.C. AND ~8"x6" EXP BOLTS @ 32" O.C. w/ 2" WASHER
AutoCAD SHX Text
9'-4"
AutoCAD SHX Text
9'-4"
AutoCAD SHX Text
#5 IN GROUTED CELL @ 7'-4" O.C. AT INTERIOR (48" O.C. EXTERIOR)
AutoCAD SHX Text
8" MASONRY BOND BEAM w/ 1#5
AutoCAD SHX Text
2 HOUR MASONRY FIREWALL PER FBC721 "PRESCRIPTIVE FIRE RESISTANCE". SEE TABLE ON A-4
AutoCAD SHX Text
ROOF SHEATHING SHALL BE FIRE RETARDANT TREATED PLYWOOD WITHIN 4'-0" OF EACH SIDE OF DIVIDING WALL PER FBC 706.4.1.1
AutoCAD SHX Text
2x6 PT BLOCKING, FASTEN w/ 10d CASE HARDENED NAILS @ 8" O.C.
AutoCAD SHX Text
NAIL ROOF SHEATHING TO BLOCKING w/ 8d RING SHANK @ 6" O.C.
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
FILL AIR GAP WITH "Thermafiber brand FireSpan insulation", OR EQUIVALENT
AutoCAD SHX Text
ROOF SHEATHING SHALL BE FIRE RETARDANT TREATED PLYWOOD WITHIN 4'-0" OF EACH SIDE OF DIVIDING WALL PER FBC 706.4.1.1
AutoCAD SHX Text
2x6 PT BLOCKING, FASTEN w/ 10d CASE HARDENED NAILS @ 8" O.C.
AutoCAD SHX Text
NAIL ROOF SHEATHING TO BLOCKING w/ 8d RING SHANK @ 6" O.C.
AutoCAD SHX Text
TOP OF RAKE BEAM, HOLD DOWN APPROXIMATELY 1~8" FROM TOP OF TRUSS
AutoCAD SHX Text
FILL AIR GAP WITH "Thermafiber brand FireSpan insulation", OR EQUIVALENT
AutoCAD SHX Text
S-3
AutoCAD SHX Text
3
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
SHEET OF
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
DWB/DWB
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/15/19
AutoCAD SHX Text
AS NOTED
AutoCAD SHX Text
DR11270
AutoCAD SHX Text
3
AutoCAD SHX Text
FOR SCOSTA TRUSSES, JOB # 44151GB, DATED 06/18/19, REVISED: 09/30/19
AutoCAD SHX Text
1526 SIGNATURE VILLA
AutoCAD SHX Text
STRUCTURAL DETAILS FOR
AutoCAD SHX Text
4467, 4471 DUTCHESS PARK ROAD FORT MYERS, FLORIDA LOTS: 312, 313 SUBDIVISION: LINDSFORD II
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL