Page 1 of 3 Corgan Internal File Location: G:\PROJECTS\19340\0000\D-Contract Admin\01-Bidding\Bid Addenda\Addendum 1\ROISD Ag Science Project Center - Addendum #01.docx
Addendum Summary 19340.0000, AG SCIENCE PROJECT CENTER
Date: 12/9/2019 12:00 PM
To: Kevin Freels
Assistant Superintendent for District Operations Red Oak ISD
109 W. RED OAK RD.
RED OAK, TX 75154
Addendum: 001 Prepared
By:
Rebekah Gallagher
This addendum contains changes to the requirements of the contract drawings and/or project manual.
Such changes shall be incorporated into the contract documents and shall apply to the work with the
same meaning and force as if they had been included in the original documents. Wherever this
addendum modifies a portion of the paragraph of project manual or any portion of the drawing, the
remainder of the paragraph of drawing affected shall remain in force.
The conditions of the basic project manual shall govern all work described in this addendum.
Wherever the conditions of work and the quality of quantity of materials or workmanship are not fully
described in this Addendum, the conditions of work, etc. included in the basic project manual for
similar items of work shall apply to the work described in this addendum.
The “Conditions of the Contract” apply to all work described in this Addendum. The following changes
shall be and are hereby made:
Summary of Revisions
SPECIFICATON REVISIONS:
ITEM 1.001. Section 08 71 00 Door Hardware
1. Revise Part 2.6 Keying
Factory construction master keyed locksets.
A. Owner will establish keying based on GMK system. Provide following
number of keys:
1. GMK: Six each.
2. MK: Six each.
3. Change Keys: Three for each lock
12/9/2019
Page 2 of 3 Corgan Internal File Location: G:\PROJECTS\19340\0000\D-Contract Admin\01-Bidding\Bid Addenda\Addendum 1\ROISD Ag Science Project Center - Addendum #01.docx
4. Construction keys: 12 master keys.
B. Construction Keying: Provide keyed construction cores for locks during
construction.
C. Index, tag and deliver permanent keys in sealed container to Owner.
D. Contractor to provide keyed permanent cores for installation by Owner.
Owner to provide permanent cores and keys (Everest Primus and Everest
as Required.)
2. Remove Hardware Group No. 001.
3. Remove Hardware Group No. G004.
ITEM 1.002. Section 08 33 23 Overhead Coiling Doors
1. Revise Part 2.2 Door Assembly
I Manual Door Operator
1. 8’ x 8’ Doors: Chain Hoist Operation
2. 12’ x 10’ Doors: Chain Hoist Operation
3. Revise Part 2.8 Manual Door Operators
B. Omit Reference to Push-Up Door Operation.
C. Omit reference to Crank Operator. Provide Manual Chain Hoist
Operation equal to ControlGard Model CG by Cornell Iron Works, Inc.
Provide chain keeper locks for chain hoist operation.
DRAWING REVISIONS:
ITEM 1.003. The following STUCTURAL SHEETS, Issued in their entirety:
Sheet Number Sheet Name
1. S01-01 General Notes
2. S01-02 Statement of special Inspections
3. S02-01 Foundation Plan
4. S03-01 Typical Concrete Details
5. S03-02 Concrete Details
6. S04-01 Typical Masonry Details
7. S05-01 Typical Steel Details
ITEM 1.004. Sheet A08-01 WINDOW, DOOR & FRAME DETAILS & DOOR SCHEDULE
1. Revise Door Schedule to Delete all hardware Group No 001. District to provide
locking hardware.
ITEM 1.005. Sheet EP02-01 – ELECTRICAL FLOOR PLAN, Reissued in its entirety
1. See attached revised sheet EP02-01 for added panel “AL3”
2. See revised Wash rack area to include added circuits.
3. See revised Office 06 for added power to IT Rack, refer to plan note 12.
Page 3 of 3 Corgan Internal File Location: G:\PROJECTS\19340\0000\D-Contract Admin\01-Bidding\Bid Addenda\Addendum 1\ROISD Ag Science Project Center - Addendum #01.docx
ITEM 1.006. Sheet EP08-01 – ELECTRICAL PANELBOARD SCHEDULE & RISER DIAGRAM
Reissued in its entirety
1. See attached sheet EP08-01 for changes to panelboard schedule and riser diagram.
ITEM 1.007. Sheet EL02-01 – LIGHTING FLOOR PLAN, Reissued in its entirety
1. See attached revised sheet EL02-01 for changes to switching layouts.
ITEM 1.008. Sheet MH02-01 – MECHANICAL FLOOR PLAN, Reissued in its entirety
1. See attached revised sheet MH02-01 for duct changes.
ITEM 1.009. Sheet MH08-01 – MECHANICAL SCHEDULE, Reissued in its entirety
1. See attached revised sheet MH08-01 for changes to the grille schedule.
End of Addendum Summary
CC: David Safir
Attachments: S01-01, S01-02, S02-01, S03-01, S03-02, S04-01, S05-01, EP02-01, EP08-01, EL02-
01, MH02-01, MH08-01
Please review this information and advise writer of any corrections, misunderstandings, or additions within 3 business days.
STANDARD ABBREVIATIONS
ABADDL
ADJAESS
AFF
AGGRALT
ARCHBLBL
BLDGBLK
BMBOT, B
BRGBTWN
CCFMFCGS
CIPCJ
CLCMU
COLCOMPCONC
CONNCONSTR
CONTCOORD
CTRCW
dbDBADEG
DETDIA or Ø
DIMDWG
DWLEA
EFEJEL
ELEVENGR
EQEW
EXP BTEXSTEXT
FFABR
FDTNFIN
FIN FLR, FFFLR
FSFVGC
GNGR
GR BMHORIZ, H
HSAHSS
HTIFINFO
INTINTERM
JSTJT
K
Anchor BoltAdditional
AdjacentArchitectural Exposed
Structural SteelAbove Finished Floor
AggregateAlternate
Architect(ural)Building LineBrick Ledge
BuildingBlock
BeamBottom
BearingBetween
ChannelCold-Formed Metal FramingCenter of Gravity of Steel
Cast-in-PlaceConstruction Joint
Center LineConcrete Masonry
ColumnCompressionConcrete
Connect(ion)Construction
ContinuousCoordinate
CenterCurtain Wall
Bar Diameter(s)Deformed Bar AnchorDegree(s)
DetailDiameter
DimensionDrawing
DowelEach
Each FaceExpansion JointElevation
ElevatorEngineer
EqualEach Way
Expansion BoltExistingExterior
Force (Axial)Fabricator
FoundationFinish
Finish FloorFloor
Far SideField VerifyGeneral Contractor
General NotesGrade
Grade BeamHorizontal
Headed Stud AnchorHollow Structural Section
HeightInside FaceInformation
InteriorIntermediate
JoistJoint
Kip (1,000 pounds)
K-FTLBF
LLBBLLH
LLVLSH
LSVLT
MMATLMAX
MECHMEP
MFRMIN
MKMTL
NICNONS
NSGNTS
OCOF
OP HDOPNGP
P-TPCC
PENPI
PILPL
PNLPSFPSI
PTR
RECTREF
REINFREQD
RTSCSCHED
SECTSHT
SIMSOG
SPASPECSQ
STSTD
STIFSTL
STRUCTSUPPT
SYMMTT&B
TEMPTOC
TOFTOJ
TOPTOS
TOWTYPULT
UNOV
VERT, VWD
WP
Kip-Feet (Moment)Pound-Force
Long Leg Back-to-BackLong Leg Horizontal
Long Leg VerticalLong Side Horizontal
Long Side VerticalLeft
MomentMaterialMaximum
MechanicalMech/Elec/Plumbing
ManufacturerMinimum
MarkMetal
Not in ContractNumberNear Side
Non-Shrink GroutNot to Scale
On CenterOutside Face
Opposite HandOpeningPan (form)
Post-TensioningPrecast Concrete
PenetrationPlasticity Index
PilasterPlate
PanelPounds Per Square FootPounds Per Square Inch
PointRadius
Rectangle(ular)Refer (to)
ReinforcingRequired
RightSlip-CriticalSchedule
SectionSheet
SimilarSlab-on-Grade
Space(ing)SpecificationsSquare
Stirrup(s)Standard
StiffenerSteel
Structure(al)Support
SymmetricalTensionTop and Bottom
TemperatureTop of Concrete
Top of FootingTop of Joist
Top of PierTop of Steel
Top of WallTypicalUltimate (force)
Unless Noted OtherwiseShear
VerticalWood
Working or Work Point
21 17 13 9 5 1
22 18 14 10 6 2
23 19 15 11 7 3
24 20 16 12 8 4
DETAIL REFERENCENUMBER
DETAIL SHEET LAYOUT
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S01-01
GENERAL NOTES
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
G E N E R A L N O T E S
DRAWING LIST
SHEET
NUMBER SHEET NAME
S01-01 GENERAL NOTES
S01-02 STATEMENT OF SPECIAL INSPECTIONS
S02-01 FOUNDATION PLAN
S03-01 TYPICAL CONCRETE DETAILS
S03-02 CONCRETE DETAILS
S04-01 TYPICAL MASONRY DETAILS
S05-01 TYPICAL STEEL DETAILS
SECTION 1 - GENERAL INFORMATION AND DESIGN CRITERIA
SECTION 1.1 - DOCUMENTS
1.1.1 Structural Drawings are not stand-alone documents. They are
augmented by technical specifications and must be coordinated
with Architectural, Civil and
Mechanical/Electrical/Plumbing/HVAC documents.
1.1.2 General Notes and Typical Details apply generally throughout
the project wherever conditions similar to those depicted exist
and are not necessarily referenced specifically in the documents.
1.1.3 Structural documents are protected by U.S.A. Copyright Laws,
and shall not be used for any purpose other than construction
of the building described in the Architectural documents and
at the geographic location shown. The structural design
described in these documents is not valid for any other purpose,
use or location.
1.1.4 The Geotechnical Report referenced herein is not part of the
Structural Documents. However, a copy should be obtained for
reference during installation of foundations and subgrade
preparation.
COORDINATION
1.1.5 Contractor is responsible for coordinating Structural Documents
with other trades and disciplines including; architectural,
civil, mechanical, electrical, HVAC and fire protection. Some
requirements are not known prior to issue and may change as
layout and fabrication drawings are developed. Promptly report
deviations and interferences with structural components for
resolution by the Engineer.
1.1.6 Contractor shall verify dimensional location and depth of slab
recesses and offsets with Architectural Drawings.
1.1.7 Contractor shall verify weights, location and details of
structurally supported mechanical equipment prior to
construction of the supporting structure. Report deviations from
assumed conditions to the Engineer prior to fabricating
materials.
1.1.8 Contractor shall verify size, location and detail of roof
openings and curbs for mechanical equipment prior to fabricating
materials. Report deviations from assumed conditions to the
Engineer before proceeding with work.
1.1.9 Contractor shall verify size and location of floor and roof
penetrations shown on structural drawings with other
disciplines. Submit for approval a composite drawing showing
all proposed openings and sleeves through structural members
for engineering review prior to or simultaneous with shop
drawings for affected framing.
1.1.10 Do not scale plans, details and sections for quantity, length
or fit of materials.
REFERENCE ELEVATIONS
1.1.11 Heights of floor and roof decks and various framing components
are given on the drawings relative to a reference elevation of
100'-0". This reference elevation is equivalent to a Mean Sea
Level Elevation of 552.00', as noted in the Civil drawings.
TEMPORARY BRACING
1.1.12 Structural systems are designed for in-place conditions only.
Contractor shall provide temporary bracing of structural
components (including but not limited to beams and walls)
for conditions that will exist during construction and to
meet all regulatory requirements for safety of workmen.
1.1.13 Temporary frame bracing shall remain until installation of
permanent structural bracing elements, member connections and
floor and roof diaphragms are complete.
SECTION 1.2 - CODES AND STANDARDS
1.2.1 Building Code of jurisdiction : 2012 International Building Code
1.2.2 Structural Concrete Code - American Concrete Institute (ACI) 318
1.2.3 Structural Steel Code - American Institute of Steel Construction
(AISC) 360
1.2.4 Structural Masonry Code - Masonry Standards Joint Committee (MSJC)
TMS 402-11/ACI 530-11/ASCE 5-11
SPECIAL INSPECTIONS
1.2.5 See Statement of Special Inspections for minimum special
inspections and testing per the Building Code.
1.2.6 See Technical Specifications for other materials testing and
inspection requirements.
SECTION 1.3 - DESIGN CRITERIA
1.3.1 Metal Building System Structural Loads
Dead, Live, Wind and Seismic loading used to design
Pre-Engineered Metal Building shall be submitted for approval
per General Note Section 5.6.
1.3.2 Live Loads
Mezzanine Storage 125 psf
1.3.3 Dead Loads
Mezzanine Collateral 10 psf (1)
(1) Collateral loads include: lighting, ductwork,
miscellaneous framing.
1.3.4 Wind Loads
Ultimate Design Wind Speed (Vult) 115 psf
Nominal Design Wind Speed (Vasd) 90 psf
Risk Category II
Wind Exposure Classification C
1.3.5 Seismic Loads
Risk Category II
Seismic Importance Factor 1.00
Mapped Spectral Acceleration, Ss 0.087
Mapped Spectral Acceleration, S1 0.049
Site Class C
Spectral Response Coeff, Sds 0.070
Spectral Response Coeff, Sd1 0.056
Seismic Design Category A
SECTION 2 - FOUNDATIONS AND RELATED EARTHWORK
GEOTECHNICAL REPORT
2.1 Design of foundations and structural components in contact with
soil is based on the recommendations given in the following:
Report by : Alpha Testing
Date of Report : November 20, 2019
Report Number : G192627 (1)
(1) Report Addendum Issued on December 3, 2019
2.2 Refer to the soil report for subsoil conditions that may be
encountered in the installation of foundations, and other
information relevant to foundations and site preparation.
SOIL IMPROVEMENT UNDER BUILDING SLABS
2.3 Design of soil-supported building slabs is based on a range of
soil movement of 0 to 1 inch, based on the recommendations of
Geotechnical Report.
2.4 Refer to Specifications for soil stabilization under
soil-supported building slabs.
STRAIGHT SHAFT PIERS
2.5 Design Criteria:
Bearing Stratum : Gray Limestone
Top of Stratum Elevation : 70'-0"
(for Bidding Purposes Only)
Allowable End Bearing : 50,000 psf
Positive Side Friction : 7,500 psf
Upheaval Side Friction : 2,000 psf
Upheaval Design Depth : 12 ft
Negative Side Friction : 6,000 psf
2.6 Pier depths indicated are for bidding purposes only. Actual pier
depths may vary depending on depth to bearing stratum.
2.7 See typical details for steel dowels at tops of piers.
2.8 Top of pier elevations given are relative to reference elevation
100'-0".
2.9 Overpour at tops of piers ("mushrooms") shall be removed to the
required pier diameter.
SECTION 3 - STRUCTURAL CONCRETE
SECTION 3.1 - CONCRETE FORMS
3.1.1 Formed Voids - Provide retained void spaces between bottom of
structural members and subgrade as follows:
Grade Beams 8 inches
3.1.2 Grade Beams - shall be formed both sides unless specifically
shown or noted otherwise in the details.
SECTION 3.2 - STEEL REINFORCING
STEEL REINFORCING
3.2.1 All bars shall be deformed in accordance with ASTM A615.
Reinforcing indicated to be welded shall conform to ASTM A706.
3.2.2 Strength of bars shall be as follows:
All Bars Grade 60
SPLICING OF REINFORCING BARS
3.2.3 Top bars in beams, slabs or joists shall be spliced at midspan
between supports, unless noted otherwise.
3.2.4 Bottom bars in beams, slabs or joists shall be spliced at
supports, unless noted otherwise.
LAPPED SPLICE LENGTHS
3.2.5 Lap reinforcing 24 bar diameters at splices unless noted or
detailed otherwise.
3.2.6 Tension splice lengths shall be calculated in accordance with
ACI 318. Use Class "B" splices unless noted otherwise
3.2.7 Welded wire fabric splice length (overlap), measured between
outermost cross wires of each fabric sheet, shall be at least
one spacing of cross wires plus 2 inches, but in no case less
than 6 inches.
CONCRETE COVER TO REINFORCING
3.2.8 Clearance from face of concrete to face of reinforcing:
Piers 3"
Formed Grade Beams 1 1/2" top, 2" sides, 3" bottom
PLACEMENT OF REINFORCING
3.2.9 Offsets in reinforcing bars shall be bent at a ratio of 1
(normal to bar axis) to 6 (parallel to bar axis).
3.2.10 Provide corner bars at intersections of beams and walls in
accordance with Typical Details.
3.2.11 Provide dowels from grade beams or foundation equal in size and
spacing to vertical bars in walls or pilasters and extend one
splice length above and below joint line, unless noted otherwise.
3.2.12 Start stirrup spacing in beams 2 inches outside of face of
supports.
3.2.13 Place welded wire reinforcing in slabs on concrete joists, in
toppings, or in slabs poured on metal deck at center of slab
unless noted otherwise.
SECTION 3.3 - CONCRETE MIX DESIGNS
3.3.1 Concrete Mix Schedule:
a) "HRC" refers to hardrock concrete having air dry unit
weight of approximately 145 PCF.
b) "LWC" refers to sand lightweight concrete having an air
dry unit weight not to exceed 120 PCF.
c) Where w/c ratio is not indicated in the Concrete Mix
Schedule, it shall be as necessary to meet strength requirements.
d) Where the w/c ratio is shown, it shall be adhered to regardless
of strength requirements.
e) "Strength" is required compressive cylinder strength
at an age of 28 days.
---------------------------------------------------------
Conc. Strength Agg. Agg. Slump Max
Class psi Type Size Inches w/c Notes
---------------------------------------------------------
A 4000 HRC 1-1/2" 5-7 ---
B 4000 HRC 1" 3-5 ---
C 3500 HRC 1" 3-5 ---
D 3500 HRC 3/4" 3-5 ---
E 3000 LWC 3/4" 2-4 ---
3.3.2 Mix Usage Schedule:
---------------------------------------------------------
Concrete Air
Description of Use Class Content
---------------------------------------------------------
Drilled Piers A ------
Grade Beams & Pedestals B 3-6%
Slab-on-Grade C 3-6%
Slab on Composite Metal Deck D 3-6%
Housekeeping Pads E ------
SECTION 3.4 - CONCRETE SLABS
3.4.1 Slabs Placed on Grade
Location Thickness Reinforcing
---------------------------------------------------------
Typical 5 inches See Typical Details
See Plan 6 inches See Typical Details
a) Provide construction joints in slabs where indicated on
Plans. Allow minimum of 4 days interval between placing
adjacent sections of slab.
3.4.2 Slabs on Composite Metal Deck
Composite Slab Schedule:
Type Overall Typ Slab
Mark T-inches Reinf
----------------------------------------------------------
A 5.0 #3 @ 12 EW
Slab types correspond to deck type (see Composite Metal Deck).
Locate Typ Slab Reinf at center of slab above deck.
Top Cover for Addnl Top Reinf: 1".
SECTION 3.8 - DRILLED IN ANCHORS
3.8.1 Drill holes with rotary impact hammer drill using carbide tipped
bits. Drill bits shall be of the diameter as specified by the
anchor manufacturer. All holes shall be drilled perpendicular
to the concrete or masonry surface.
3.8.2 Embedded items: Identify position of reinforcing steel and other
embedded items prior to drilling holes for anchors. Exercise
care in drilling to avoid damaging existing reinforcing or
embedded items. Notify the Engineer if reinforcing steel or
other embedded items are encountered during drilling. Take
precautions as necessary to avoid damaging electrical and
telecommunications conduit, and gas lines.
3.8.3 Base Material Strength: Unless otherwise specified, do not drill
holes in concrete or masonry until concrete, mortar, or grout
has achieved full design strength.
TESTING
3.8.4 Continuous special inspection is required for adhesive anchors.
Remove and replace mis-placed or malfunctioning anchors. Clean
and fill empty anchor holes and patch failed anchor locations
with high-strength nonshrink, nonmetallic grout. Anchors that
fail to meet proof load or installation torque requirements
shall be regarded as malfunctioning.
EXPANSION, UNDERCUT, SCREW AND ADHESIVE ANCHORS
3.8.5 Concrete base material: provide anchors of size and type shown
with ICC-ES or IAPMO-UES compliance required
Expansion Anchors: Hilti Kwik Bolt TZ (ICC-ES ESR-1917)
Screw Anchors: Hilti Kwik HUS-EZ (ICC-ES ESR-3027)
Adhesive Anchors: Hilti HIT-HY 200 Safe Set System
(ICC-ES ESR-3187) for use with Hilti
HIT-Z Rod, HAS-E Rod, & Hollow Drill Bit
3.8.6 Grout filled CMU (Concrete Masonry Unit) base material: provide
anchors of size and type shown with ICC-ES or IAPMO-UES
compliance required
Screw Anchors: Hilti Kwik HUS EZ (ICC-ES ESR-3056)
Adhesive Anchors: Hilti HIT-HY 70 (ICC-ES ESR-2682)
INSTALLATION
3.8.7 Perform anchor installation in accordance with manufacturer's
printed installation instructions (MMPII).
3.8.8 Protect threads from damage during anchor installation.
3.8.9 IBC 2012 requires ACI/CRSI certification for adhesive anchor
installers (AAI) when installing adhesive anchors of
horizontally or upwardly inclined conditions. Installers of
adhesive anchors shall hold a current AAI certification as
accredited by ACI/CSRI in accordance with ACI 318-11 D.9.2.2.
Anchor Manufacturer Installation Training is acceptable as a
supplement to ACI\CRSI AAI certification. Installers shall
submit their certifications to the inspector (testing lab) for
each installation.
SECTION 4 - STRUCTURAL MASONRY
GENERAL
4.1 Refer to Architectural layout and Drawings and Specifications
for details and exact dimensions of brick masonry work including
rustications, corbels, coursing, reglets, weep holes,
waterproofing and flashing.
4.2 Grouting of reinforced masonry walls shall be accomplished in
accordance with TMS 602.
STRUCTURAL PROPERTIES
4.3 Required prism strength of structural assembly = 2000 psi
4.4 Concrete Masonry Units: 8" (Nominal Thickness) ASTM C90
Lightweight with a maximum unit weight of 105 pcf and a
minimum net area compressive strength of 2800 psi
4.5 Masonry Mortar: ASTM C270, Type S (Proportion Specification)
Masonry cement shall not be used for mortar.
Required 28-day compressive strength = 1800 psi
4.6 Masonry Grout: ASTM C476 (Proportion Specification)
Required 28-day compressive strength = 2000 psi
REINFORCING
4.7 Horizontal joint reinforcing shall be "Ladder Type" 9 ga. welded
wire spaced 16 inches on center vertically.
4.8 Provide special "L" and "T" shaped sections at wall
intersections. Lap horizontal wires at least 12" at splices.
4.9 The first cell at corners, ends of walls, and each side of
openings shall be grouted and reinforced with 1 #5 vertical.
SECTION 5 - STRUCTURAL STEEL
SECTION 5.1 - STRUCTURAL FRAME
5.1.1 Structural Steel Properties:
High Strength Steel ASTM A992 Grade 50
Use High Strength Steel for W Shapes and WT's, u.n.o.
Structural Steel (Normal Strength) ASTM A36
Use for Angles, Channels, and Plates, u.n.o.
Steel Pipes ASTM A53, Grade B
Hollow Structural Sections (HSS) ASTM A500, Grade B
Erection Bolts ASTM A307
High Strength Bolts ASTM A325N
Anchor Bolts ASTM F1554 Grade 36
High Strength Anchor Bolts ASTM F1554 Grade 105
WELDING
5.1.2 Unless otherwise noted, angles, plates, rods, and miscellaneous
framing shall be welded at contact joints and supports. Weld
sizes shall conform to AWS D1.1 minimums, except where noted
otherwise.
5.1.3 Where fillet weld sizes are not indicated on weld symbols,
fillet size shall be 1/16th inch smaller than thickness of
thinner of materials being joined.
5.1.4 Complete penetration welds are indicated by notation "CP" on
weld symbols, partial penetration by "PP".
STRUCTURAL BOLTS
5.1.5 Bolts indicated on details shall be 3/4 inch diameter, unless
noted otherwise.
5.1.6 Bolts shall be tightened by the AISC "Snug Tight" method unless
noted otherwise.
MISCELLANEOUS
5.1.7 Shelf angles supporting masonry shall have 1/4 inch wide
expansion joints spaced not more than 40 feet apart.
5.1.8 Edge angles at perimeters of floors and roofs noted as "CHORD
MEMBERS" or "CONTINUOUS" on details shall be butt welded at
splices to develop full allowable tensile strength of member.
5.1.9 Edge angles supporting floor or roof deck shall be spliced only
over supports.
5.1.10 Steel members shown to be curved shall be rolled in a manner
that will not cause distortion or buckling. Should alterations
to the member size, such as a thicker flange or web, be required
to ensure this outcome, the additional steel shall be provided
at no additional cost to the contract.
COMPOSITE STEEL BEAMS
5.1.11 Beams shall have shear studs spaced at 2 feet maximum on center,
whether shown or not.
5.1.12 Composite steel beams do not require shoring during placement
of concrete slab, unless noted otherwise.
SHEAR STUDS
5.1.13 Shear studs shall be fusion-welded, headed studs of high
strength steel.
5.1.14 Unless noted otherwise, studs shall have a shank diameter of
3/4-inch and a length of 4 inches, after being welded.
SECTION 5.3 - COMPOSITE METAL DECK
5.3.1 Contractor shall provide composite metal decking to meet the
following criteria:
1. Decking alone shall be capable of supporting the wet weight
of concrete plus construction loads without requiring
intermediate shoring for all span conditions on the project,
unless noted otherwise.
2. Composite slab and deck system shall be capable of supporting
design loads indicated on the drawings for all span conditions
on the project.
Deck thickness, indicated by gauge in Composite Steel Deck Schedule,
is a minimum and shall be increased as necessary to meet these
requirements, at no additional cost to the Contract.
5.3.2 Composite Steel Deck Schedule:
Type Deck Min Min Min Min Min
Mark Height Gauge +Ix-in4 -Ix-in4 +Sx-in3 -Sx-in3
------------------------------------------------------------
A 2.0" 20 0.409 0.406 0.341 0.346
a) Yield Strength = 50 ksi min
(Deck Type A applies throughout)
5.3.3 Composite floor system minimum load capacity requirements:
Type Superimposed Concentrated
Uniform Load (psf) Load (lbs) *
---------------------------------------------------------
A 150 2000
*Concentrated load acting on area 2.5 ft x 2.5 ft; not
acting simultaneously with uniform load.
5.3.4 Composite Deck Connections:
Type A - 5/8" puddle welds at each valley at each support, and
at 18" o.c. parallel to deck edge.
Sidelaps - button punch at 3'-0"
SECTION 5.6 - PRE-ENGINEERED METAL BUILDING (PEMB)
5.6.1 Superstructure is Pre-Engineered Metal Building (PEMB).
Contractor shall coordinate with PEMB Manufacturer for EOR
structural review of delegated design prior to fabrication.
5.6.2 The PEMB shall be a manufacturer's standard prefabricated
metal structure of the approximate inside area shown.
Rigid frames shall be spaced as shown on the plan. Overall
dimensions and construction details may vary to suit
manufacturer's standard design. However, minimum web
thickness of rigid frames shall be 3/16".
5.6.3 The PEMB shall be designed and fabricated according to the
contract specifications, AISC, MBMA, and AISI latest
specifications. American institute of steel construction
certification is required of the metal building system
manufacturer and a certificate to verify compliance shall
be submitted with the design analysis. The dimensional
tolerances outlined in the AWS code under workmanship and
the tolerances applicable to hot rolled steel under the
AISC "Standard Mill Practice" section shall be required in
the fabrication of the steel building frames.
5.6.4 PEMB individual components and frame deflections and drift
shall be designed in accordance with Technical Specification.
5.6.5 A complete design analysis showing all the calculations for
the rigid frames, girts, purlins, and x-bracing for wind and
seismic loads and a layout of anchor bolts and other
embedded items shall be submitted for approval with the
erection drawings, pior to fabrication.
5.6.6 The PEMB shall be designed to support all mechanical equipment
including heaters, sprinklers, exhaust systems, fans and all
other such devices. Additional girts or purlins shall be
placed in convenient locations for attachment of all mechanical
equipment.
5.6.7 Design loads shall conform with criteria given in the general
notes, plus collateral load from mechanical equipment, ceilings,
and sprinklers as applicable. Load combinations and design
stresses should comply with AISC specifications for
structural steel buildings.
5.6.8 Rigid frame anchor bolts shall be designed and furnished by
the contractor. Bolts shall be designed by a professional
engineer for the frame reactions furnished by the metal
building manufacturer. The anchor bolt design analysis shall
be submitted for approval.
S T A T E M E N T O F S T R U C T U R A L S P E C I A L I N S P E C T I O N S2 0 1 2 I N T E R N A T I O N A L B U I L D I N G C O D E
STATEMENT OF SPECIAL INSPECTIONS NOTES:
This Statement of Special Inspections is submitted in accordance with Section 1704 of the 2012 International Building Code (referenced hereforth as Code). It includes a Schedule of Special Inspection Services applicable to the Project.
If applicable, it includes Requirements for Seismic Resistance and/or Requirements for Wind Resistance.
The Owner shall employ one or more qualified Special Inspectors to perform this work. The Special Inspector(s) shall keep records of all inspections and shall furnish interim inspection reports to the Building Official and to the Registered Design Professional in
Responsible Charge. Discrepancies shall be brought to the immediate attention of the Contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the Building Official and the Registered Design Professional in Responsible Charge prior to completion of that phase of work. A Final Report of Special Inspections
documenting required special inspections and corrections of any discrepancies noted in the inspections shall be submitted to the Building Official and the Registered Design Professional in Responsible Charge at the conclusion of the project.
The Special Inspection program does not relieve the Contractor of responsibility to comply with the Contract Documents. Jobsite
safety and means and methods of construction are solely the responsibility of the Contractor.
See specifications for additional testing requirements. Where conflicts occur, the most stringent requirement shall control.
INSPECTION OF FABRICATORS:
Where fabrication of structural load-bearing members and assemblies is being performed on the premises of a
fabricator's shop, special inspection of the fabricated items shall be required by Section 1704.2 and as required elsewhere in the Code.
INSPECTION OF WELDING:
Welding inspection shall be in compliance with AWS D1.1. The basis for welding inspector qualification shall beAWS D1.1.
INSPECTION OF STRUCTURAL STEEL:
Special inspection of structural steel shall be in accordance with the quality assurance inspection requirements ofAISC 360.
INSPECTION OF STRUCTURAL MASONRY:
Structural masonry construction shall be inspected and verified in accordance with TMS 402/ACI 530/ASCE 5
and TMS 602/ACI 530.1/ASCE 6 Level B Quality Assurance Program requirements.
SCHEDULE OF SPECIAL INSPECTION SERVICES
TABLE 1705.3: REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
1. Inspection of reinforcing steel, including prestressing
tendons, and placement.
5. Verifying use of required design mix.
9. Inspection of prestressed concrete:
a. Application of prestressing forces.b. Grouting of bonded prestressing tendons in
the seismic-force-resisting system.
CHECK IF
REQD
2. Inspection of reinforcing steel welding in accordance
with Table 1705.2.2, Item 2b.
3. Inspection of anchors cast in concrete where allowableloads have been increased or where strength
design is used.
6. At the time fresh concrete is sampled to fabricate
specimens for strength tests, perform slump and aircontent tests, and determine the temperature of
the concrete.
7. Inspection of concrete and shotcrete placement
for proper application techniques.
8. Inspection for maintenance of specified curing
temperature and techniques.
10. Erection of precast concrete members.
11. Verification of in-situ concrete strength, prior to
stressing of tendons in post-tensioned concrete andprior to removal of shores and forms from beams
and structural slabs.
12. Inspect formwork for shape, location, and dimensions
of the concrete member being formed.
SCHEDULE OF SPECIAL INSPECTION SERVICES
TABLE 1705.6: REQUIRED VERIFICATION AND INSPECTION OF SOILS
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
1. Verify materials below shallow foundations are adequate to
achieve the design bearing capacity.
CHECK IF
REQD
2. Verify excavations are extended to proper depth and have
reached proper material.
3. Perform classification and testing of compacted fill materials.
5. Prior to placement of controlled fill, observe subgrade and
verify that site has been prepared properly.
4. Verify use of proper materials, densities, and lift thicknesses
during placement and compaction of controlled fill.
SCHEDULE OF SPECIAL INSPECTION SERVICESTABLE 1705.8: REQUIRED VERIFICATION AND INSPECTION OF CAST-IN-PLACE
DEEP FOUNDATION ELEMENTS
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
1. Observe drilling operations and maintain complete and
accurate records for each element.
CHECK IF
REQD
2. Verify placement locations and plumbness, confirm element
diameters, bell diameters (if applicable), lengths, embedmentinto bedrock (if applicable), and adequate end-bearing strata
capacity. Record concrete or grout volumes.
3. For concrete elements, perform additional inspections in
accordance with Table 1705.3.
X---
--- ---
X---
X ---
X ---
X---
X
X---
X---
X---
X---
X---
X---
X---
X ---
X---
X ---
X ---
--- ---
4. Inspection of anchors post-installed in hardened
concrete members.X---
SCHEDULE OF SPECIAL INSPECTION SERVICES TABLE 1705.2.2:
REQUIRED VERIFICATION AND INSPECTION OF STEEL CONSTRUCTION OTHER THAN STRUCTURAL STEEL
VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
1. Material verification of cold-formed steel deck:
CHECK IF
REQD
2. Inspection of welding:
X---
X---
a. Identification markings to conform to ASTM standards specified in the approved construction
documents.
b. Manufacturer's certified test reports.
a. Cold-formed steel deck:
1) Floor and roof deck welds. X---
b. Reinforcing steel:
1) Verification of weldability of reinforcing
steel other than ASTM A706.X---
2) Reinforcing steel resisting flexural and axial forces in intermediate and special moment
frames, and boundary elements of special structural walls of concrete and shear
reinforcement.
X ---
3) Shear reinforcement.
4) Other reinforcing steel. X---
X ---
X---
TOC 99' - 0" TOP OF CONCRETE ELEVATION
TOW 124' - 0" TOP OF WALL ELEVATION
SECTION
SYMBOL LEGEND
ENLARGED PLAN OR
PLAN DETAIL
LEVEL ELEVATION(RELATIVE TO DATUM
ELEVATION 100' - 0")
TOS 120' - 0" TOP OF STEEL ELEVATION
(BOTTOM OF METAL DECK)
CAST-IN-PLACE
CONCRETE WALL
CONCRETE MASONRY
WALL
EL 120' - 0" SPOT ELEVATION
DROP IN STRUCTURE
SLOPE IN STRUCTURE
MECHL. EQUIPMENT
SEE PLAN FOR WEIGHT
1
S101
LEVEL 2
115' - 0"
PEMB COLUMN
P2
PIER MARK
99' - 0"TOP OF PIERELEVATION
(REFER PLAN)
SP
OT
ELE
VA
TIO
NS
AR
ER
ELA
TIV
E T
O D
AT
UM
ELE
VA
TIO
N10
0' -
0"CONCRETE TOPPING
SLAB
1
S101ELEVATION
1
S101
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S01-02
STATEMENT OF
SPECIAL
INSPECTIONS
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
1
1
2
2
3
3
4
4
5
5
6
6
A
B
C
D
E
F
G
H
J
K
L
2.2 3.5 4.8
1' - 3 1/2" 20' - 0" 20' - 0" 19' - 4" 19' - 4" 19' - 4" 1' - 3 1/2"
16' -
1"
15' -
7"
15' -
7"
15' -
7"
15' -
7"
16' -
6"
16' -
6"
16' -
6"
17' -
1"
1' - 3 1/2" 20' - 0" 20' - 0" 19' - 4" 19' - 4" 19' - 4" 1' - 3 1/2"
SLOPE TO
DRAIN, TYP
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P3
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
165'
- 0
"
3' -
6"
1' -
0"
1' - 0"
SLOPE DOWN
1/4" PER FT
24' - 6" 24' - 6" 24' - 6" 24' - 6"
98' - 0"
4' - 10" 4' - 4" 24' - 0" 6' - 9 1/2"
1' - 0"
30' - 7"
6"63
' - 9
"
14
S03-02
1
S03-02
5
S03-02SIM
5
S03-02 TYP @
SLAB
TOC 100' - 0"
TOC 100' - 0" TOC 100' - 0"
SAWJOINTS @ 15'-0" OC MAX
TYP WHERE SHOWN
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
97' - 0"
P2
9 5/
8"6"
3
S03-02
3
S03-02
3
S03-02
1
S03-02
NO SLAB
NO SLAB
6
S03-02 TYP @
INT SOIL
6
S03-02 TYP @
INT SOIL
6
S03-02 TYP @
INT SOIL
5
S03-02
TYP
9
S03-02
9
S03-02
9
S03-02
8
S03-02 TYP
8
S03-01 TYP @ INTERIOR NON-
LOAD BEARING CMU
13
S03-02
13
S03-02
78' -
5"
66' -
7"
20' -
0"
98' - 0"
6"9
5/8"
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
97' - 0"
P1
10' - 0" 20' - 0 1/2" 19' - 8 1/2" 9' - 7" 5' - 7"12' -
0"
12' -
9"
3"
2
S03-02 @ OVERHEAD
DOOR
4
S03-02 @ OVERHEAD
DOOR
4
S03-02 @ OVERHEAD
DOOR
2
S03-02 @ OVERHEAD
DOOR
5
S03-02 TYP @
SLAB
1
S03-02
2
S03-02 @ OVERHEAD
DOOR
9
S03-02
9
S03-02
SLOPE DOWN
1/4" PER FT
7
S03-01
12' -
0"
12
S03-02
TYP
SLAB ON GRADE THICKNESS TO BE 6" @
AREAS SHOWN HATCHED
5
S03-02 SIM
97' - 0"
P2
16' - 0"
11'-3 1/4"
14
S03-02
10
S03-02
EXTENTS OF ROOF ABOVE
- SEE ARCH
CMU CONTROL JOINTS, TYP WHERE SHOWN. 24' - 0" OC MAX.
SUBMIT LOCATIONS FOR REVIEW.
ME
TA
L B
UIL
DIN
G
BR
AC
ED
BA
Y
ME
TA
L B
UIL
DIN
G
BR
AC
ED
BA
Y
5"
10 1/2"
10 1/2"
5"
PROVIDE
THICKENED SLAB & FDN DWLS PER
@ NOTCH 8/S03-01
1 2
A
B
C
D
E
16' -
1"
15' -
7"
15' -
7"
15' -
7"
1' -
5"
20' - 0" 11' - 7"
W18x35 (30)
W18x35 (30)
W18x35 (30)
W18x35 (30)
W18x35 (30)
W18x35 (30)
W18x35 (30)
63' -
9"
6"
1' - 0" 30' - 7"
TOS 111' - 7"TOS 112' - 2 3/4"
TOS 111' - 7"TOS 112' - 2 3/4"
18
S04-01
17
S04-01
17
S04-01
18
S04-01
8 E
QU
AL
SP
AC
ES
CMU TO MAINTAIN 4" CLR FROM METAL BUILDING STRUCTURE.
COORD CMU LOCATION W/ METAL BLDG DESIGNER & ARCH PRIOR
TO SUBMITTING SHOP DWGS.
SEE & FOR PIPE PENETRATIONS & OPNGS
SMALLER THAN 18".
13/S05-01 14/S05-01
FOR OPNGS LARGER THAN 18", FRAME OPENING W/ W12x24 W/
STUDS @ 2'-0". COORD OPENINGS W/ ARCH & MEP. SUBMIT
OPENINGS AND REQUIRED FRAMING FOR REVIEW PRIOR TO
FABRICATION.
4" T
YP
FOUNDATION LEVEL PLAN NOTES:
1. TOP OF SLAB = RELATIVE ELEVATION 100'-0" UNLESS
NOTED OTHERWISE
2. TYPICAL SLAB ON GRADE FLOOR SLAB THICKNESS = 5",
UNLESS NOTED OTHERWISE
3. SHEET INDEX:
GENERAL NOTES S01-01
STATEMENT OF SPECIAL INSPECTIONS S01-02
TYPICAL CONCRETE DETAILS S03-01
DRILLED PIER SCHEDULE S03-01
TYPICAL MASONRY DETAILS S04-01
TYPICAL STEEL DETAILS S05-01
MEZZANINE LEVEL PLAN NOTES:
1. TYPICAL MEZZANINE FLOOR IS TYPE A COMPOSITE SLAB:
3" CONCRETE ON 2" COMPOSITE METAL DECK (5" TOTAL)
2. FOR BEAM SIZE CALLOUTS, NUMBERS IN PARENTHESES ()
INDICATE THE QUANTITY OF SHEAR STUDS REQUIRED FOR THAT
BEAM. SEE TYPICAL DETAILS FOR PLACEMENT OF STUDS."C = ##"
INDICATES THE REQUIRED CAMBER AT THE CENTER OF THE BEAM.
3. SHEET INDEX:
GENERAL NOTES S01-01
STATEMENT OF SPECIAL INSPECTIONS S01-02
TYPICAL CONCRETE DETAILS S03-01
DRILLED PIER SCHEDULE S03-01
TYPICAL MASONRY DETAILS S04-01
TYPICAL STEEL DETAILS S05-01
FINISH GRADESLAB ON GRADE
DE
PT
H P
ER
GE
OT
EC
H R
PT
2' -
0"
SE
LEC
T F
ILL
CA
P
MOISTURE CONDITIONED SOILS
7' - 0" DEPTH PER GEOTECH RPT
GE
OT
EC
H R
PT
1' -
0"
DE
PT
H P
ER
EXTEND MOISTURE CONDITIONING BEYOND EDGE OF SLAB 5' - 0" AS
REQD PER GEOTECH RPT
VAPOR BARRIER PER
GEOTECH RPT
VAPOR BARRIER
SEE ARCH
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S02-01
FOUNDATION
PLAN
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
1/8" = 1'-0"
1 FOUNDATION PLAN1/8" = 1'-0"
2 MEZZANINE FRAMING PLAN
FOUNDATION DESIGNS ARE BASED ON ANTICIPATED METAL BUILDING SYSTEM STRUCTURAL LOADS. FOUNDATION DESIGNS ARE TO BE REVIEWED BASED ON ACTUAL LOADINGS PROVIDED BY THE ENGINEER OF THE METAL BUILDING. SUBMIT METAL BUILDING LOADS FOR REVIEW PRIOR TO SUBMITTING FOUNDATION SHOP DRAWINGS.
3/4" = 1'-0"
3 SUBGRADE PREP SCHEMATIC DETAIL
STRAIGHT SHAFT PIER
BEARING STRATUM
SEE GENERAL NOTES
TOP OF BEARING STRATUM
PENETRATION MEASURED FROM TOP
OF BEARING STRATUM OR BOTTOM OF STEEL CASING, WHICHEVER RESULTS
IN DEEPER PIER
TOP OF PIER ELEVATION
SEE PLAN
PIER REINFORCING -
SEE SCHEDULE
PIER TIES - SEE SCHEDULE
(SPIRAL REQUIRED IN LIEU OF TIES FOR 24" DIA PIERS AND SMALLER. SEE
NOTE BELOW FOR OTHER INFO).
FINISH FLOOR ELEVATION
PIER MARK
P2
98' - 0"TOP OF PIEREL OTHER
THAN TYPICAL
VA
RIE
S
SE
E P
LAN
SA
ND
DE
TA
ILS
PE
NE
TR
AT
ION
3" C
LR
DIA
SH
AF
T
3" C
LR
6" MIN
3" C
LR
TIE
SP
A
TY
P
SEE REBAR BENDS AND HOOKS DETAIL FOR ROUND TIE DETAIL. STAGGER TIES
SO THAT ADJACENT TIES DO NOT ENGAGE THE SAME VERTICAL BAR WITH
END HOOKS. SPIRAL REINFORCING OF EQUAL SIZE AND PITCH TO MATCH TIE
SPACING IS AN ACCEPTABLE ALTERNATIVE. PROVIDE 1 1/2 TURNS
TOP AND BOTTOM.
DOWELS / ANCHOR BOLTS
1. USE 4 #5(4-0) IN 6" x 6" PATTERN UNO.2. SEE COL SCHEDULE AND BASE PLATE
DETAILS FOR ANCHOR BOLTS.3. SEE COL SCHEDULE FOR DOWELS TO
CONCRETE COLUMNS.4. SEE PIER CAP DETAILS FOR DOWELS
TO CAPS.
2 ADDL TIES EQUALLY SPACED (SEE TYP
DETAILS FOR TIES AT STEEL COLUMN
ANCHOR BOLTS)
TIES (OR SPIRAL)
VOID BOX - BM OR WALL
GRADE BEAM
OR WALL
VOID
RETAINER
BACKFILL
CONTINUOUS MOISTURERESISTANT CARDBOARD
VOID FORM BETWEENFOUNDATION ELEMENTS,
RECTANGULAR SHAPED.
UNDISTURBED OR COMPACTED
SUBGRADE
TOP OF
FOUNDATION ELEMENT
BEYOND
SE
E G
N N
OT
ES
VO
ID D
EP
TH
DIM
"A
"
2 1/
2" M
IND
EP
TH
CO
NT
TR
EN
CH
DIM "B"
VOID
DEPTHDIM "A" DIM "B"
8" 3" MIN 3" MIN
5" MAX
WALL OR GRADE BEAM
PLAN VIEW
PROVIDE CORNER BARS
SAME SIZE & SPACINGAS HOR. WALL OR
GRADE BEAM REINF WITHCLASS A LAP SPLICE
EACH WAY
CORNER BARS
GRADE BM
BOT BARS
ELEVATION
STEP IN GRADE BEAM
6"30db
12db
REINFORCING AT SLAB-ON-GRADEBLOCKOUT
SLAB ON GRADE
BLOCKOUT FOR
PLUMBING, ETC.
#3(4-0) @
EA. CORNER
SLAB-ON-GRADE RECESSES
GREATER THAN SLAB THICKNESS LESS THAN SLAB THICKNESS
#3 @ 18
DOWELS TO MATCHSIZE AND SPACING
OF TYPICAL SLABREINFORCING -
LAP 48db
SE
E P
LAN
8"
8"
DEPTH6 X RECESS
SE
E P
LAN
(30"
MA
X)
2 #4 CONT TOP
AND BOT
#4 @12
CONT
DOWELS TO MATCH
SIZE AND SPACINGOF TYPICAL SLAB
REINFORCING
LAP 48db
CONT WATERSTOP
THICKENED SLAB
#3 @ 18
3 #5 CONTINUOUS
1' -
0"
TYP.
1' - 0"
SLAB ON GRADE
REINF CONT
1' - 0" 1' - 0"
NON-LOAD BEARING CMU CL8" NON-LOAD BEARING
CMU TO BE REINFORCED W/ #5 @ 48 IN GROUTED
CELLS UNO
#5(0-10/4-8) @ 48
SLAB ON-GRADE
1ST POUR 2ND POUR
1/8" RADIUS EACH SIDE OFJOINT, PROVIDE SAW CUT
IF JOINTS ARE TO BE SEALED
COAT WITH OIL PRIOR
TO 2ND POUR
FORMED BUTT JOINT
SMOOTH DOWEL
OR TIE BAR
SLAB ON-GRADE SCHEDULE
SLAB
THICKNESS (T)
CLEAR
COVER
SLAB
REINFORCING SMOOTH DOWELS
5" 1 3/4" #3 @ 18 EW 3/4" DIA X 1' - 2" @ 12
6" 2" #4 @ 18 EW 3/4" DIA X 1' - 2" @ 12
SAW CUT JOINTREINF CONTINUOUS THRU
SAW JOINT LOCATIONS
CONSTRUCTION JOINT DETAIL
SAW JOINT DETAIL
TIE BARS
#6(3-9) @ 12
#6(3-9) @ 12
CONSTRUCTION JOINTS
T
T/2
T/2
TT/4
CONSTRUCTION JOINTS SHALL BE "SMOOTH DOWEL" TYPE UNLESS
SPECIFICALLY NOTED ON PLAN
CO
VE
R
CLE
AR
CO
VE
R
CLE
AR
ELEVATION
FIRST POUR SECOND POUR
CONTINUE REINFORCING
THROUGH JOINT
4 #5 (4-0) CENTERED
ON JOINT
SHEAR KEY TO BE 6"
NARROWER THAN BEAMWIDTH WITH 1/2"
BEVEL 4 SIDES
GRADE BM CONSTRUCTION JOINT
2"
1/3
1/3
1/3
TOP BARS CONT AT CANTILEVERS,CANTILEVER BACKSPANS AND
SPANS LESS THAN 10' - 0".
TYP ST SPA
SPANCL SUPPORT CL SUPPORT
SPLICE BOT
BARS @ CL SUPPORT,
TYP
2"
TO FIRST
ST, TYPHOOK TOP BARS @ ENDS,
TYP AT ALLEND
CONDITIONS
SPLICE TOP BARS
@ MIDSPAN, TYP
STIRRUPS,
TYP
TYP GRADE BEAM REINF
ELEVATION
CANTILEVER
TYP ST SPA
DROP IN GRADE BEAM
ELEVATION
SAME AS TOP REINFORCING
CLASS B LAP SPLICE
DROP IN GRADE BEAM
ELEVATION
1:6 SLOPE MAXIMUM
2 ADDL STIRRUPS
2"
OFFSET BARS
STANDARD END HOOKS
STIRRUPS AND TIES
6
1 M
AX
#3 - #5
#6 - #8
12db
4db (2 1/2" MIN)
D
D
D90°
180°
D
BAR SIZE
#3 - #8#9 - #11
#14, #18
MIN BEND
DIA, D
6db8db
10db
SEE STANDARD
END HOOKBEND SCHEDULE,
TYPD
12db FOR #6 - #86db FOR #3 - #5
DD
D6db
BAR SIZEMIN BEND
DIA, D
4db
6db
ROUND STIRRUPS AND TIES
6" M
IN
REBAR BENDS AND HOOKS
"db" = NOMINAL BAR DIA
IN INCHES, TYP
SEE STIRRUPAND TIE DETAIL
FOR HOOKS
EN
GA
GE
VE
RT
RE
INF
END HOOKS (EXCLUSIVEOF STIRRUPS AND TIES)
SHALL BE STANDARDHOOKS UNLESS NOTED
OTHERWISE.
WELD SIZE
BAR SIZE WELD SIZE
#3#4
#5#6
#7#8
#9#10
#11
3/16"1/4"
5/16"3/8"
7/16"1/2"
9/16"5/8"
11/16"
STEEL
PLATE
BAR PERPENDICULAR TO PLATE
REBAR WELDING
BAR PARALLEL TO PLATE
BAR SIZE WELD LENGTH
#3#4
#5#6
#7#8
#9#10
#11
1 1/4"1 3/4"
2 1/4"2 3/4"
3 3/4"5"
6 1/4"8"
9 3/4"
BAR SPLICE
tw =
0.3
db BAR SIZEMINIMUM
SPLICE LENGTH
#3#4
#5#6
#7#8
#9#10
#11
1"1 1/4"
1 1/2"1 3/4"
2"2 1/4"
2 1/2"3"
3 1/4"
tw =
0.2
db db
WELD LENGTHSTEEL PLATE
0.2db, TYP
15° MAX
E1 E2
E3 E4
2- 1/2" D.
x 0-4 HSA
PL. 3/8"
C.L. PL.
PL. 3/8"
C.L. PL.
3-1/2" D.
x 0-6 HSA
4- 1/2" D.
x 0-4 HSA
PL. 3/8"
6- 1/2" D.
x 0-4 HSA
PL. 3/8"
C.L. PL.L-1 1/2 x1 1/2x
1/4 x0-10
EMBEDDED PLATES
4"
8"
2"4"
2"
5"
2"3"
3"2"
10"
3/16
2" 4" 4" 2"
1' - 0"
2 1/
2"6"
2 1/
2"
11"
2" 4" 2"
8"
2"4"
2"
8"
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S03-01
TYPICAL
CONCRETE
DETAILS
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
STRAIGHT SHAFT DRILLED PIER SCHEDULE
PIER MARKSHAFT
DIAMETERVERTICAL
REINF PENETRATION TIES
P1 18" 6 #7 7' - 0" #3 @ 16
P2 24" 7 #8 7' - 0" #3 @ 16
P3 30" 9 #8 7' - 0" #3 @ 16
TYPICAL DETAILNO SCALE
2XTD02110A
TYPICAL DETAILNO SCALE
3TD02526
TYPICAL DETAILNO SCALE
4TD03026
TYPICAL DETAILNO SCALE
5TD03028
TYPICAL DETAILNO SCALE
6TD03042
TYPICAL DETAILNO SCALE
7XTD03101
TYPICAL DETAILNO SCALE
8XTD03102
TYPICAL DETAILNO SCALE
9XTD03111
TYPICAL DETAILNO SCALE
10TD03140
TYPICAL DETAILNO SCALE
11TD03141
TYPICAL DETAILNO SCALE
12TD03142
TYPICAL DETAILNO SCALE
13TD03143
TYPICAL DETAILNO SCALE
24TD03201
TYPICAL DETAILNO SCALE
20TD03202
TYPICAL DETAILNO SCALE
14TD03691
1' - 6"
2' -
4"
8"
SEE PLANFACE OF BLDG
RECESS PER ARCH
EXTERIOR GRADE
#4(2-0/2-0) @ 18
W/ #4 CONT
4 #6 T&B
#4 ST @ 12
2' - 0" x 2' - 0" PEDESTAL
SEE PLAN
FACE OF BLDG
TOC EL - 102' - 0"
GR BM REINF CONT
THRU PEDESTALSEE
FOR ADDL INFO
CONSTRUCTION JOINT AT TOP OF GRADE BM.
PEDESTAL REINF TO BE CONT FROM TOP OF PIER UP
TO TOP OF PEDESTAL.
1/S03-02
CHAMFER CORNERS, TYP
FACE OF GR BM BEYOND
EXTERIOR GRADE
PEDESTAL REINF:4 #6 VERT W/
#3 TIES @ 12
PIER DOWELS:6#7 VERT W/ #3 CONTINUOUSLY
WOUND TIE. PITCH AS REQD FOR 8" SPACING & PROVIDE 1 1/2
TURNS T&B. EMBED DOWEL CAGE 4'-0" INTO PIER & EXTEND TO TOP
OF PEDESTAL W/ STD HOOK
18"
DIA
PROVIDE 4#4 TIES @ 2" AT TOP OF PEDESTAL. TIES
TO HAVE 135º HOOKS
METAL BUILDING COL ANCHORS TO HAVE
18" MIN EMBED
#3(6-0) CNTRD
ON PEDESTAL
RECESS PER ARCH
8"
#4(0-6/2-6) @ 12
CL OF PIER & PEDESTAL
2' -
4"
8"2'
- 0
"
1' - 6"
2' -
4"
1' -
0"
SEE PLANFACE OF BLDG
RECESS PER ARCH
EXTERIOR GRADE
INTERIOR GRADE
CHAMFER CORNER
SEE ARCH FOR
EXTENTS OF CURB
TOP OF CURB @ DOOR.
SEE ARCH FOR LOCATIONS & ELEVATIONS. LOWER
HAIRPINS AS REQD
4 #6 T&B
#4 ST @ 12
#4(2-6) HAIRPIN @ 12
W/ 3#4 CONT TOP
SEE
FOR ADDL INFO5/S03-02
INTERIOR GRADE
2' - 0" x 2' - 0" PEDESTAL
SEE PLAN
FACE OF BLDG
TOC EL - 102' - 0"
GR BM REINF CONT
THRU PEDESTALSEE
FOR ADDL INFO
CONSTRUCTION JOINT
1/S03-02
CHAMFER CORNERS, TYP
FACE OF GR BM BEYOND
EXTERIOR GRADE
RECESS PER ARCH
CL OF PIER & PEDESTAL
1' - 6"
2' -
4"
8"
CHAMFER CORNER
INTERIOR GRADE
#4(2-0/2-0) @ 18
W/ #4 CONT
4 #6 T&B
#4 ST @ 12
INTERIOR GRADE
2' - 0" x 2' - 0" PEDESTAL
TOC EL - 102' - 0"
GR BM REINF CONT
THRU PEDESTALSEE
FOR ADDL INFO
CONSTRUCTION JOINT AT TOP OF GRADE BM.
PEDESTAL REINF TO BE CONT FROM TOP OF PIER UP
TO TOP OF PEDESTAL.
9/S03-02
CHAMFER CORNERS, TYP
FACE OF GR BM BEYOND
PEDESTAL REINF:4 #6 VERT W/
#3 TIES @ 12
EXTEND PIER VERT REINF
TO TOP OF PEDESTAL
PROVIDE 4#4 TIES @ 2" AT TOP OF PEDESTAL. TIES
TO HAVE 135º HOOKS
METAL BUILDING COL ANCHORS TO HAVE
18" MIN EMBED
4 #6(2-0) HAIRPINS @ TOP
OF PEDESTAL EQ SPA
#4(0-6/2-6) @ 12
8"
CL OF PIER & PEDESTAL
2' -
4"
2' -
8"
1' - 6"
2' -
4"
8"
5 #6 T&B
#4 ST @ 12
1' -
8"
#5(6-0) @ 24
#4(2-0/2-0) @ 18
ALT HOOK DIRECTION
8" PARTIALLY GROUTED
CMU W/ #5 @ 24 VERT
BOTTOM 3'-0" OF CMU WALL TO BE
FULLY GROUTED
SEE PLANFACE OF BLDG
BEYOND
RECESS & SLOPE
PER ARCH
SITE PAVING
SEE
FOR ADDL INFO1/S03-02
SEE ARCH
L4 x 3 x 1/4 (LLH) CONT (GALV)
W/ 1/2" DIA x 4" HSA @ 12
3/4" DIA (2-0) SMOOTH DWL
@ 12 INTO SITE PAVING
SEE PLANFACE OF BLDG
BEYOND
SLOPE & ELEVATION
PER ARCH INTERIOR GRADE
L4 x 3 x 1/4 (LLH) CONT (GALV)
W/ 1/2" DIA x 4" HSA @ 12
SEE
FOR ADDL INFO3/S03-02
3/4" DIA (2-0) SMOOTH DWL
@ 12 INTO SITE PAVING
SITE PAVING
EXTERIOR GRADE 2' - 0" x 2' - 0" PEDESTAL
TOC EL - 102' - 0"
CHAMFER CORNERS, TYP
PEDESTAL REINF:4 #6 VERT W/
#3 TIES @ 12
EXTEND PIER VERT REINF
TO TOP OF PEDESTAL
PROVIDE (3) PEDESTAL TIES WITHIN TOP 5" OF
PEDESTAL
METAL BUILDING COL ANCHORS TO HAVE
18" MIN EMBED
4 #6(2-0) HAIRPINS @ TOP
OF PEDESTAL EQ SPA
SITE PAVING
CL OF PIER & PEDESTAL
3' - 0"
2' -
4"
8"
SEE PLANFACE OF BLDG
RECESS PER ARCH
EXTERIOR GRADE
REINF CONTINUOUS
FROM GR BM BEYOND
135º TIES
ADDL 4 #6 T&B
#4 ST @ 12
FACE OF GR BM
BEYOND
SEE
FOR ADDL INFO13/S03-02
TRENCH DRAINCOORD GEOMETRY
W/ MEP
6" TYP
1' - 0" LAP, TYP
#3 @ 18 EA WAY
6"
#3(2-0/AS REQD) @ 18, TYP
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S03-02
CONCRETE
DETAILS
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
3/4" = 1'-0"
1
3/4" = 1'-0"
5
3/4" = 1'-0"
3
3/4" = 1'-0"
6
3/4" = 1'-0"
9
3/4" = 1'-0"
8
3/4" = 1'-0"
13
3/4" = 1'-0"
2
3/4" = 1'-0"
43/4" = 1'-0"
12
3/4" = 1'-0"
143/4" = 1'-0"
10
1"BB-3 CONT
2 GROUT FILLED CELLS TO FOUNDATION W/ 1 #5 EA
CELL AT BM CENTERLINE
1/4
COURSING
ELEVATION
E2 EMBED
FULLY GROUT BM POCKET AFTER BM
IS INSTALLED
BEAM BEARING ON CMU
8" M
IN
5 1/2"
SEE
FOR ADDL INFO
18/S04-01
PROVIDE E2 DECK BEARING EMBED ON EA SIDE OF BM
POCKET & 4' - 0" OC MAX BTWN
SEE 11/S05-01
1/4" x 3" PL CONTSEE
FOR ADDL INFO
18/S04-01
BB-1 CONT
3/16
E2 EMBED @ ENDS OF WALLS
& 4' - 0" OC MAX BTWN
TOS EL - VARIES
SEE PLAN
C9x15 CONT W/ #4 (2-0)
A706 DWL @ 12" OCMITER CHANNEL & BUTT
WELD AT CORNERS
SEE PLAN FOR DECK
SPAN DIRECTION
RAILING - SEE ARCH
1 1/
2"
1/4" x 3" PL CONT
CMU LINTELS
CMU LINTEL SCHEDULE
8"
NOTES:1. BOTTOM COURSE OF LINTEL SHALL BE CONSTRUCTED OF
SOLID-BOTTOM,TROUGH-STYLE BLOCKS, UNLESS OTHERWISE NOTED.2. A CMU LINTEL IS REQUIRED FOR OPENINGS GREATER THAN
16 INCHES IN WIDTH.3. LINTEL REINFORCEMENT MAY NOT BE LAP SPLICED ABOVE AN
OPENING.4. CONTROL JOINTS ARE NOT PERMITTED TO OCCUR WITHIN LINTEL
REINFORCEMENT.5. SEE CMU WALL REINFORCING DETAIL FOR VERTICAL REINFORCEMENT PLACEMENT AT JAMBS
6. EXTEND HORIZONTAL REINFORCEMENT 24 INCHES OR 40 BAR DIAMETERS BEYOND THE FACE OF OPENING. PROVIDE STD HOOK AT
END OF BAR IF HORIZONTAL EXTENSION IS NOT POSSIBLE. 7. PRECAST CONCRETE LINTELS OF THE SAME SIZE AND LENGTH MAY
BE SUBSTITUTED EXCEPT THAT TOP BARS SHALL BE PROVIDED EQUAL TO SCHEDULED BOTTOM BARS.
FU
LLY
GR
OU
TE
D
NO
MIN
AL
LIN
TE
L D
EP
TH
WALL
THICKNESS
LINTEL
DEPTH
MAX
OPENING
TOP
REINF
BOT
REINF
MA
X
4"
2 #4
2 #4
2 #4
2 #4
16"
24"
6' - 0"
10' - 0"
TOP REINF
BOT REINF
2" C
LR
MIN
1 1/
2" C
LR
SUPPORT TOP REINF
ON SAW-CUT CROSS-WEBS
SUPPORT BOT REINF
WITH BAR POSITIONER
8" CMU
SHEAR
REINF
NONE
#3 @ 8
SHEAR REINF
WHERE REQD
CMU w/ 1 VERTICAL BAR
(8" NOMINAL):
PLAN VIEW
BAR POSITIONER
LOCATE HORIZ BAR REINF
OUTSIDE OF VERTICAL BARS
CMU REINFORCEMENT LAYOUT, BOND BEAMS, AND SPLICE SCHEDULE
CENTER
VERT BAR
BB-1
BB-3
7 5/
8"
7 5/8"
2 #5 CONT
1' -
3 5
/8"
7 5/8"
1 #5 T&B CONTOFFSET BARS
AROUND VERT
CMU REINFORCEMENT LAYOUT NOTES:1. LOCATE VERTICAL OR HORIZONTAL REINFORCEMENT AT LEAST 1/2" FROM CMU SHELL
TO ALLOW FOR PROPER GROUT CONSOLIDATION.2. THESE BOND BEAMS APPLY TO WALLS WHERE BOND BEAMS ARE NOT SPECIFICALLY
REFERENCED. REFER TO SECTIONS & DETAILS FOR SPECIAL BOND BEAMS THAT ARE REQUIRED.3. CONSTRUCT BOTTOM COURSE OF A BOND BEAM USING SOLID BOTTOM,
TROUGH-STYLE MASONRY UNITS, UNO.
HORIZONTAL CMU BOND BEAM REINFORCEMENT
MASONRY SPLICE SCHEDULE - GRADE 60
BAR
SIZE
#4 24"
#5 36"
#6 54"
64"
72"
#7
#8
NOTES:
1. SPLICE LENGTHS GIVEN ARE FOR GRADE 60 REINFORCING BARS.2. USE LONGEST LENGTH WHEN SPLICING BARS OF DIFFERENT SIZE.
3. INCREASE SPLICE LENGTH OF EPOXY-COATED REINFORCEMENT 50% OVER TABLE VALUES, UP TO A MAXIMUM OF 96 BAR DIAMETERS
4. SEE PLAN VIEWS FOR DEFINITION OF HORIZ, EDGE VERT, AND CENTER VERT BARS.
1900 - 2000 PSI 2500 PSI
16"
24"
45"
62"
72"
20"
32"
54"
64"
72"
HORIZ OR
EDGE VERT
CENTER
VERT
14"
22"
40"
54"
72"
HORIZ OR
EDGE VERT
CENTER
VERT
f'm
REINFORCEMENT SPACING
2" T
YP
STEP IN BOND BEAM
PROVIDE STD HOOKON BOND BEAM REINF
@ END OF STEP, TYP
ELEVATION
CONTINUOUS
BOND BEAM REINFORCIN
G
STEP LENGTH
4' - 0"4' - 0"
5' - 4"
#4#5
#6
BAR
SEE SCHEDULE
STEP LENGTH
8" M
AX
2" 2"
BOND BEAM INTERSECTIONS
PLAN VIEW
CORNER BARS NOT REQUIRED WHERE
CONTROL JOINT IS SPECIFIED AT THIS SIDE
OF T-INTERSECTION PROVIDE CORNER BARS
THAT ARE THE SAME SIZE & SPACING AS HORIZONTAL
BOND BEAM REINFORCINGW/ TYPICAL LAP SPLICE
LENGTH EACH WAY
PROVIDE CORNER BARS THAT ARE THE SAME
SIZE & SPACING AS HORIZONTAL BOND
BEAM REINFORCINGW/ TYPICAL LAP SPLICE
LENGTH EACH WAY
CONTROL JOINT
WHERE SPECIFIED
CMU WALL OPENING REINFORCING
CMU JAMB REINFORCING SCHEDULE
MAX OPNG
WIDTHJAMB WIDTH
NOTES:1. SEE CMU LINTEL SCHEDULE FOR REINFORCEMENT ABOVE OPENINGS.
2. SEE TABLE FOR CMU SILL BEAM REINFORCEMENT BELOW OPENINGS.
3. SEE TABLE FOR CMU JAMB REINFORCEMENT ADJACENT TO TYPICAL
OPENINGS UNLESS NOTED OTHERWISE. JAMB REINFORCEMENT IS REQUIRED FOR ALL OPENINGS GREATER THAN 16 INCHES IN WIDTH.
4. SEE RELATED WALL SECTIONS AND ELEVATIONS FOR SIZE AND LOCATIONS OF BOND BEAMS
5. SEE LAP SPLICE SCHEDULE FOR MINIMUM REQUIRED SPLICE LENGTHS.
6. EXTEND VERTICAL REINFORCEMENT TO TOP OF WALL FOR OPENINGS IN AN EXTERIOR WALL. EXTEND VERTICAL REINFORCEMENT TO TOP OF WALL OR
A MINIMUM OF LAP SPLICE LENGTH PER SCHEDULE PAST FLOOR LEVEL ABOVE FOR OPENINGS IN AN INTERIOR WALL.
7. TYPICAL WALL REINFORCEMENT IS NOT SHOWN FOR CLARITY. THE MAXIMUM
SPACING BETWEEN ANY TWO ADJACENT GROUTED AND REINFORCED VERTICAL OR HORIZONTAL CELLS SHALL NOT EXCEED REQUIREMENTS SHOWN IN GENERAL NOTES, DETAILS, OR ELEVATIONS.
8. MISCELLANEOUS MEP OPENINGS 16" WIDE OR SMALLER DO NOT REQUIRE
JAMB OR LINTEL REINFORCEMENT.
CMU SILL REINFORCING SCHEDULE
MAX OPNG
WIDTHDEPTH REINF
ELEVATION VIEW
CMU
OPNG WIDTHOPNG WIDTH
3
3
5
1
2
1
4 6
8" CMU8' - 8"
12' - 8"
8"
16"
2 #4
2 #5 T&B
6' - 0" 16"
10' - 0" 24"
OPNG WIDTH
8
TOS 100' - 0"FLOOR OR ROOF
TOS 100' - 0"LEVEL 1
TOS 100' - 0"TOP OF WALL EL
LEVEL
MIN
2' - 0"
OPNG WIDTH
8
MASONRY CONSTRUCTION JOINT
HORIZONTALCONSTRUCTION
JOINT
SE
E S
CH
ED
ULE
FO
R L
AP
SP
LIC
E
PROVIDE BAR POSITIONERS
BETWEEN BLOCKS,IN BED JOINTS, AT SPLICES
SEE REINFORCEMENT LAYOUT
1 1/
2" G
RO
UT
KE
Y, T
YP
DO NOT FORM GROUT KEY WITHIN A BEAM OR LINTEL. DO NOT
INSTALL HORIZONTAL CONSTRUCTION JOINT WITHIN LAP
SPLICE.
MASONRY WALL BRACING
STEEL BEAM ORJOIST REFER
TO PLANS
L-3x3x 1/4
@ 4-0 O.C.
L-3x2x 1/4 x 0-4(LLV) EA. SIDE @
4-0 OC MAX
1" C
LRTYP.
TYP.
MASONRY WALL BRACING
STEEL BEAM ORJOIST REFER
TO PLANS
1" C
LR
L-3x2x 1/4 x 0-8(LLV) EA. SIDE @
EA. BM. OR JSTTYP.
MASONRY WALL BRACING
STEEL BEAM ORJOIST REFERTO PLANS
3"
1" C
LR
BENT PL- 1/4 "x4"LONG SPACED @4-0 OC
TYP.
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S04-01
TYPICAL
MASONRY
DETAILS
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
TYPICAL DETAILNO SCALE
17
1" = 1'-0"
18
TYPICAL DETAILNO SCALE
5XTD04101
TYPICAL DETAILNO SCALE
10XTD04102
TYPICAL DETAILNO SCALE
3TD04103
TYPICAL DETAILNO SCALE
4TD04104
TYPICAL DETAILNO SCALE
12XTD04120
TYPICAL DETAILNO SCALE
9TD04130
TYPICAL DETAILNO SCALE
13TD04170
TYPICAL DETAILNO SCALE
14TD04171
TYPICAL DETAILNO SCALE
15TD04172
BEAMSIZE
ANGLELENGTH (L)
NO. OF ROWSOF BOLTS (N)
5-1/2"
8-1/2"
14-1/2"
14-1/2"
20-1/2"
REFER TO AISC TABLES 10-1 & 10-2.
NO. OF ROWSOF BOLTS (N)
ANGLELENGTH (L)
11-1/2"
23-1/2"
1 3/
4" M
AX
. W33
& W
36
HEAVYSTANDARD
NOTES:
2
5-1/2" 8-1/2"
W8, W10
W14, W16
3
14-1/2"W18
17-1/2"W21
11-1/2"
11-1/2"
W24 20-1/2"
W27
W30
W33
17-1/2" 26-1/2"
29-1/2"
23-1/2"W36 29-1/2"
W12
1. WELD A IS 3/16" FOR STANDARD 1/4" FOR HEAVY.
2. BOLTS ARE ASTM A325N U.N.O.3. BEAM CONNS ARE STANDARD UNLESS DENOTED
BY AN HC ON PLAN. COPE AS REQ'D. @
BM. TO BM. CONN.
5/16" THICK DBL. ANGLES
w/ 3/4" DIA. A325 BOLTS
BM. OR COL. WEB,
OR COL. FLANGE
1 1/
4" M
AX
. UP
TO
W30
L
1-1/
4" VARIES t
GAGE
N B
OLT
S @
3"
2
3
4
4
5
5
6
7
8
4
5
6
7
8
9
10
10
BOLTED/BOLTED CONN.
BOLTED/WELDED CONN.SIMPLE SHEAR STEEL BEAM CONN.
WELD A
1. EXTENDED CONNECTIONS (IN WHICH THE END OF THE SUPPORTED BEAM STOPS SHORT OF THE COLUMN OR GIRDER FLANGES) ARE NOT ALLOWED, UNLESS SPECIFICALLY DETAILED IN THE DRAWINGS.
NOTES:
SUBMIT CALCULATIONS FOR EACHDIFFERENT CONNECTION, SIGNED ANDSEALED BY A PE REGISTERED IN THE
STATE OF THE PROJECT
PROVIDE AISC STANDARD CONNECTIONDETAIL TO MEET MINIMUM REQUIREDSTRENGTH AS LISTED IN THE TABLE
USE DOUBLE ANGLECONNECTION AS
DETAILED
YES, BUT FABRICATOR WISHES TOSUBSTITUTE EITHER DIFFERENT
CONNECTION COMPONENTS OR ADIFFERENT CONNECTION TYPE
NOYES
DOES CONNECTION GEOMETRY ALLOWFOR THE USE OF DOUBLE ANGLE
CONNECTION AS DETAILED?
SIMPLE SHEAR CONNECTION FLOW CHART
66
58
50
46W14
W16
260181
308242
300215
230150
170
130
94
38
N.A.W10
W36
W33
W30
W27
W24
92
78
W21
W18
W12
W8
21
N.A.
MINIMUM CONNECTION DESIGN STRENGTH(LRFD, KIPS)
128
28
17
HEAVYSTANDARDBEAM SIZE
N.A. N.A.
SLAB REINF.
CENTERED INSLAB ABOVE
DECK
COMPOSITE BEAM
TANDEM ROW TRIPLE ROWMIN. BEAM FLANGE = 9"
SINGLE ROWMIN BEAM FLANGE = 6"
1 1/
2" M
IN.
AB
OV
E D
EC
KA
FT
ER
WE
LDIN
G
1 1/
2" M
IN.
AB
OV
E D
EC
KA
FT
ER
WE
LDIN
G
1 1/
2" M
IN.
AB
OV
E D
EC
KA
FT
ER
WE
LDIN
G
1-1/2" FOR 3/4" DIA. STUDS1-3/4" FOR 7/8" DIA. STUDS
3" FOR 3/4" DIA. STUDS3 1/2" FOR 7/8" DIA. STUDS
STUD WELDING DETAILS
C.L. BEAM &
SHEAR STUDS
C.L. BEAM &
SHEAR STUDS
A. UNIFORM STUD LAYOUT. EXAMPLE 1. PLACE STUDS EVENLY DISTRIBUTED ALONG
LENGTH OF BEAM AT 2'-0" O.C., STARTING AT 3" FROM EACH END OF BEAM.
2. PLACE ADDITIONAL STUDS AT 6" O.C. FROM EACH END OF BEAM. USE TANDEM OR TRIPLE
ROWS AS REQUIRED. 3. TOTAL NUMBER OF STUDS SHALL NOT BE LESS
THAN SHOWN ON PLAN.
GIRDER
B. SEGMENTED STUD LAYOUT. EXAMPLE 1. PLACE STUDS EVENLY DISTRIBUTED ALONG
LENGTH OF BEAM AT 2'-0" O.C. STARTING AT 3" FROM EACH END OF BEAM.
2. PLACE ADDITIONAL STUDS BETWEEN IN- FRAMING BEAMS TO PROVIDE FOR NUMBER OF STUDS SHOWN ON PLAN. USE TANDEM
OR TRIPLE ROWS AS REQUIRED. 3. MINIMUM STUD SPACING ALONG LENGTH OF
BEAM IS 6" O.C.
W24x55 (42)
W24x55
20 2010
1. PLACE STUDS EVENLY DISTRIBUTED ALONG LENGTH OF BEAM AT 2'-0" O.C.
2. PLACE ADDITIONAL STUDS AT 1'-0" O.C. FROM EACH END OF BEAM. USE TANDEM OR
TRIPLE ROWS AS REQUIRED.3. TOTAL NUMBER OF STUDS SHALL NOT BE
LESS THAN SHOWN ON PLAN.
SIMPLE BEAM
LOCATE STUD IN SIDEOF FLUTE CLOSEST
TO END OF BEAM
3"3"
STUD LAYOUT - COMPOSITE BEAMS
"B"
"A"
"D2"
"D1"
THIS IS CONSIDERED A
SINGLE OPENING
WEBS OF DECK
BEAM BELOW
TYPICAL L1 3/4 x 1 3/4 x 1/4 EXTEND
ANGLE 3 DECK WEBS PAST EDGE OF OPENING
1/8 1/2
EA DECK
FLUTE
NOTES:1. DO NOT CUT MORE THAN 2 ADJACENT WEBS.
2. SINGLE HOLES LESS THAN 6" IN DIAMETER AND CUTTING NO MORE THAN 1 DECK WEB NEED
NO REINFORCING.3. ANGLES SHALL BE PLACED ON TOP OF DECK.
4. IF DIMENSION "A" IS GREATER THAN 4D1, 4D2, OR 32" (WHICHEVER IS LARGEST), THEN THERE IS NO RESTRICTION ON DIMENSION "B".
5. IF DIMENSION "B" IS GREATER THAN 4D1, 4D2, OR 32" (WHICHEVER IS LARGEST), THEN THERE
IS NO RESTRICTION ON DIMENSION "A".6. IF DIMENSIONS "A" AND "B" ARE LESS THAN 4D1, 4D2, OR 32" (WHICHEVER IS LARGEST),
THE OPENING GROUP WILL BE CONSIDERED AS A SINGLE HOLE, AND MUST BE REINFORCED AS
REQD FOR LARGER OPENING AS SHOWN IN 14/S05-01
CLR
3/4"
1/8 1 1/2"@ FLUTE
MIN
"W" "W"
MIN
"W"
MAX3"
MAX3"
OPNG
18" MAX
SECTION
SECTION
#4 TRIM BAR - EXTEND 2'-0"
BEYOND OPNG, TYP @ CONC DECK
L 1 3/4 x 1 3/4 x 1/4 WHERE "W" IS 6" TO 12"L 2 x 2 x 1/4 WHERE "W" IS 12" TO 18"
INSTALL PRIOR TO CUTTING HOLE
OPNG
18" MAX
OPEN
TYP
"W"
#4 (3'-0") DIAG BARSOVER ANGLES, TYP AT
RE-ENTRANT CORNERS
#4 TRIM BARS TYP
REINF ANGLE
DECK
SPAN
PLAN VIEW
REINFORCING AT 6" TO 18" WIDE OPENING IN COMPOSITE SLAB
COPED CHANNEL OR BEAM
A572 GR. 50 PLATE
TO MATCH WIDTH & THICKNESS OF BEAM
FLANGE (1/2" MIN.) 1/4
SE
CT
ION
SR
EF
ER
TO
AS REQ'D. 8"UNO
OVERHANG POUR STOP POUR STOP
1/4 " BENT PL
14 GA
12 GA
10 GA
1/4 " BENT PL
3/16 " BENT PL
10 GA
12 GA< 5"
T < 6 1/2 T <6 1/2 < 7 1/2"
REFER PLANT POUR STOP
SEE PLAN FOR
DECK DIRECTION
OVERHANG
SLAB EDGE - COMPOSITE DECK
2-12
5 < 8"
8" < 11"
EXTEND SLAB REINF
TO EDGE OF SLAB
1/2" MAX
2" @ Bf 5"
1 1/2" @ Bf 5"
1/8 10 GAGE
3/16 PL-3/16
DECK BRG LENGTH PER DECK
SUPPLIER, 1 1/2" MIN
11" < 14"
L.A. FUESS PARTNERS, INC.Structural Engineers3333 Lee Parkway, Suite 300 • Dallas, TX 75219214.871.7010 • www.lafp.com
DATE
JOB
SHEET
ISSUES
Date of issue:
REVISIONS
LAFP PROJ. NO. 19273 FIRM REG. NO. F-537
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
1 12.09.2019 ADDENDUM #01
2
3
4
5
6
7
8
9
10
S05-01
TYPICAL STEEL
DETAILS
12.09.2019
19340.0000
12.09.2019
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
TYPICAL DETAILNO SCALE
6TD05200
TYPICAL DETAILNO SCALE
12TD05350
TYPICAL DETAILNO SCALE
8TD05355
TYPICAL DETAILNO SCALE
7TD05356
3/4" = 1'-0"
13 TYPICAL PIPE PENETRATIONS THRU COMPOSITE SLAB
TYPICAL DETAILNO SCALE
14
TYPICAL DETAILNO SCALE
11XTD05210
TYPICAL DETAILNO SCALE
15TD05323
EF
EF
PS
P
J J J
J
JJJ
J
EF
EF
EF
EF
WALKWAY
10
WALKER AREA
09
SHOW RING
07
STORAGE
01
MULTI-PURPOSE ROOM
02
WASHRACK
189
WASHRACK
190
WASHRACK
191
RR
03
RR
04
W/H & W/D
05
OFFICE
06
TREADMILL AREA
08
ANIMAL PENS
11
5
5
5
5
5
6
6
6
4
4
4
4
4
4
4
2
4
44
4
4
WH
2
2
555 5 5 5
2
2
2
2
5
3
UH #
04
UH #
03
UH #
02
EF #
11A
EF #
11B
EF #
11C
EF #
11D
UH #01
AC #
06
AC #
02
UH #
08
UH #
07
UH #
06
UH #05
EF #
04
EF #
03
5
5
5
5
AH
ADP
AL2
9
9
9
9
15
222
2
2
2
2 2
2
2
2
2
4
4
4
4
5 5 5
TXAL
11
1111
11
1111
4
AL
AL-6
ADP-8
AH-26
AL2-10
AL2-4
12
11 11 11
2 2 2 2
4
HVLS #
11A
HVLS #
11B
HVLS #
11C
HVLS #
11D
HVLS #
11E
HVLS #
11F
HVLS #07
AL-1 AL-9
AL-17AL-21
AL-13
AL-5
AH-20
AH-14
AH-25
AH-19AH-13AH-7
AH-1
AL2-3
AL2-5
AL2-1
AL2-29
AL2-31
AL2-27
AL2-2
AL2-9
AL2-11
AL2-13
AL2-17
AL2-20AL2-22
AL2-24
AL2-18AL2-14 AL2-16
AL2-23
AL2-25
AL2-15
AL2-7
AL-2
AL2-8
AL-18AL-22
AL-14
AL-28
AL-26
AL-27
AL-25
10
10
10
10
10
10 10
1016
AL2-26
AL2-28
17
18
19
19
AL3
AL3-2
AL3-4 AL3-6 AL3-8
AL3-11AL3-1 AL3-3
AL3-5 AL3-7AL3-9 AL3-10
1
119
12AL3-12
1
4
4
AL-10
AL-18
AH #
06
AH #
02
ADP-7
Tyler | Austin | Houston | DFW | El PasoTBPE Firm Registration No. F-893www.EMAengineer.comPhone: 1 . 800 . 933 . 0538
EMA Engineering & Consulting
NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE AND WORKINGSYSTEM.
SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTING AND
DATE
JOB
SHEET
ISSUES
REVISIONS
12/9
/201
9 8
:24:0
5 A
M
EP02-01
ELECTRICALFLOOR PLAN
12/03/2019
19340.0000
EP
02-0
1E
LE
CT
RIC
AL F
LO
OR
PLA
N
CORGAN401 N. Houston StDallas, TX 75202T: 214-748-2000
2
1 12/03/2019 ISSUE FOR CONSTRUCTION
3
4
5
6
7
8
9
10
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
SEE SHEET E07-01 FOR GENERAL NOTES AND PLAN NOTES APPLICABLE TO THE ENTIRE DRAWING SET.
CIRCUIT ALL FIRE ALARM SAFETY FUNCTION DEVICES IN THIS AREA TO AL2-1. SEE GENERAL NOTES ON NOTES SHEET FOR MORE INFORMATION ON THESE DEVICES.
ELECTRICAL GENERAL NOTES(SOME NOTES MAY NOT BE USED)
1.
2.
1/8" = 1'-0"1 ELECTRICAL FLOOR PLAN
WEATHERPROOF GFCI MAINTENANCE OUTLET MOUNTED BELOW DISCONNECT.
GFCI OUTLET INSTALLED 48" A.F.F.
EWC OUTLET INSTALLED 20" A.F.F. - ON GFCI BREAKER.
GFCI OUTLET INSTALLED 18" A.F.F.
WEATHERPROOF GFCI MAINTENANCE OUTLET 18" A.F.F.
GFCI OUTLET INSTALLED 44" A.F.F.
HAND DRYER - COORDINATE EXACT MOUNTING HEIGHT WITH ARCHITECT. REFER TO SPECIFICATIONS FOR MORE INFORMATION.
PROVIDE MOMENTARY SWITCH FOR MOTORIZED OVERHEAD DOOR.
PROVIDE AND INSTALL SWITCH AT 48"A.F.F. TO CONTROL FAN. VERIFY EXACT LOCATION WITH ARCHITECT/OWNER. SEE SHEET MH08-01 MECHANICAL SCHEDULE FOR MORE INFORMATION.
SEE SHEET MH08-01 MECHANICAL SCHEDULE FOR CONTROL TO UNIT HEATER. VERIFY EXACT LOCATION WITH ARCHITECT/OWNER.
CEILING-MOUNTED OUTLET FOR 208V ELECTRIC CORD REEL. SEE DETAIL #4 ON SHEET EP07-02 FOR MORE INFORMATION. COORDINATE EXACT LOCATION AND ELEVATION WITH ARCHITECT/OWNER PRIOR INSTALLATION.
PROVIDE A (120V 20A) OUTLET FOR RACK. COORDINATE EXACT REQUIREMENT AND HEIGHT WITH OWNER.
LAWN IRRIGATION CONTROLS. RUN A 3/4" CONDUIT TO ENERGY MANAGEMENT CONTROL PANEL. PROVIDE TWO 3" CONDUITS FOR CONTROL WIRING UNDERGROUND TO LANDSCAPE AREA. EXTEND CONDUIT 5'-0" BEYOND CONCRETE OR BUILDING IN LANDSCAPE AREA. CAP EACH END.
MILLWORK RECEPTACLES - PROVIDE A 1" CONDUIT FROM ACCESSIBLE ATTIC SPACE, RUN DOWN INSIDE NEAREST WALL AND UNDER SLAB TO J-BOXES. RUN CONDUIT CONCEALED IN MILLWORK TO OUTLETS SHOWN. DO NOT MOUNT OUTLET FACEPLATE FACING UP IN MILLWORK. VERIFY EXACT LOCATION OF J-BOX PRIOR TO CONCRETE POUR WITH FURNITURE INSTALLER.
PROVIDE A KNOX BOX FOR EMERGENCY POWER SHUT OFF. PROVIDE A SHUNT TRIP AT SERVICE DISCONNECT. REFER TO EMERGENCY POWER DISCONNECT DETAIL. PROVIDE NECESSARY CONTROL WIRING FROM SHUNT LOCATED IN SWITCHGEAR TO THE KNOX BOX WITH A POWER OFF SWITCH LOCATED INSIDE THE KNOX BOX. CONFIRM WITH THE CITY ORDINANCE THE EXACT TYPE OF SWITCH REQUIRED.
WEATHERPROOF GFCI MAINTENANCE OUTLET. COORDINATE EXACT LOCATION AND HEIGHT WITH ARCHITECT PRIOR INSTALLATION. SEE DETAIL #10 ON SHEET EP07-02 FOR MORE INFORMATION.
PROVIDE A NEMA 3R ENCLOSURE DISCONNECT AS SHOWN, FOR LOW VOLTAGE 120/208V PANEL "AL" REFER TO SHEET EP09-01 RISER DIAGRAM FOR MORE INFORMATION. CONFIRM WITH THE OWNER/ARCHITECT THE EXACT TYPE OF SWITCH REQUIRED.
FIRE ALARM PANEL. PROVIDE CONDUITS TO ATTIC SPACE PER FIRE ALARM CONTRACTOR SHOP DRAWINGS. INSTALL EMPTY 3/4" CONDUIT TO ATTIC SPACE FOR FUTURE.
PROVIDE SURFACE MOUNTED PANELS. REFER TO EP08-01 ELECTRICAL PANELBOARD SCHEDULE & RISER DIAGRAM FOR MORE INFORMATION.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ELECTRICAL PLAN NOTES(SOME NOTES MAY NOT BE USED)
1/8" = 1'-0"2 ELECTRICAL FLOOR PLAN - MEZZANINE
16
17
1 12/09/2019 ADDENDUM #01
18
19
EP08-01
ELECTRICAL
PANELBOARD
SCHEDULE &
RISER DIAGRAM
DATE
JOB
SHEET
ISSUES
REVISIONS
10
/2
2/2
01
9 9
:4
5:5
6 A
M
12/03/2019
19340.0000
ET
02
-0
1E
LE
CT
RIC
AL
C
OM
MU
NIC
AT
IO
NS
F
LO
OR
P
LA
N
CORGAN
401 N. Houston St
Dallas, TX 75202
T: 214-748-2000
2
1 12/03/2019ISSUE FOR CONSTRUCTION
3
4
5
6
7
8
9
10
AG
S
CIE
NC
E
PR
OJE
CT
C
EN
TE
R
15
4 L
ou
ise
R
itte
r B
lvd
, R
ed
O
ak, T
X 7
51
54
AND NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE AND
WORKING SYSTEM.
SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOB
CONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTING
Tyler | Austin | Houston | DFW | El PasoTBPE Firm Registration No. F-893www.EMAengineer.comPhone: 1 . 800 . 933 . 0538
EMA Engineering & Consulting
12/09/2019ADDENDUM #01
GENERAL RISER NOTES:
1. WHEREVER THE LENGTH OF THE SECONDARY CONDUCTORS OF ANY
TRANSFORMER EXCEEDS TEN FEET, AN ENCLOSED CIRCUIT BREAKER OR
FUSED DISCONNECT IS REQUIRED TO BE PROVIDED WITHIN TEN FEET OF THE
TRANSFORMER SECONDARY TERMINALS IN ACCORDANCE WITH NEC ARTICLE
240-21(C)(2). THIS OVERCURRENT DEVICE SHALL HAVE AN AMP RATING EQUAL
TO THE AMP RATING OF THE PANEL BEING SERVED. IF THIS OCCURS AND THE
PANEL IS IN THE SAME ROOM, THE PANEL BEING FED MAY BE CHANGED TO
MAIN LUG ONLY.
2. SERVICE ENTRANCE FEEDERS DO NOT REQUIRE AN EQUIPMENT GROUNDING
CONDUCTOR.
3. PROVIDE AND INSTALL BURNDY OR NSI (OR APPROVED EQUIVALENT) UL RATED
COMPRESSION REDUCING PIN TERMINALS ON COPPER / ALUMINUM
CONDUCTORS AS REQUIRED. SEE IMAGE TO THE RIGHT
4. UTILITY WORK SHOWN HERE IS PROPOSED AND MAY NOT INCLUDE ALL UTILITY
COMPANY REQUIREMENTS. COORDINATE FINAL UTILITY LOCATION, EASEMENT
REQUIREMENTS, TRANSFORMER SIZE AND LOCATION, TRANSFORMER PAD
SIZE, MEANS OF DISCONNECT REQUIREMENTS, ETC. WITH UTILITY COMPANY
BEFORE BIDDING.
500 2-2 1/2"C. WITH 4-#250 MCM, 1-#2 GRN IN EACH
300G #2/0 GRN
4-#4, 1-#10 GRN, 1 1/2"C.60
15G #8 GRN
45G
75G
30G
#4 GRN
#2 GRN
#6 GRN
3-#1/0, 1-#6 GRN, 1 1/2"C.
3-#6, 1-#10 GRN, 1"C.
3-#10, 1-#10 GRN, 3/4"C.
3-#4, 1-#8 GRN, 1"C.
PRIMARY SIDE OF XFMR [480 VOLT]
45P
75P
15P
30P
225G
150G
#2/0 GRN
#1/0 GRN
4-#1/0, 1-#6 GRN, 2"C.
4-#6, 1-#8 GRN, 1"C.
4-#250 MCM, 1-#2 GRN, 2 1/2"C.
2-2"C. WITH 4-#3/0, 1-#2 GRN IN EACH.
4-#2/0, 1-#4 GRN, 2"C.
SECONDARY SIDE OF XFMR [208]
30S
75S
112S
45S
15S
112P 112G #2 GRN3-#2/0, 1-#6 GRN, 1 1/2"C.
TRANSFORMER GROUNDS
80
125
150
100
225
250
200
400
600
300
800
175
3-3"C. WITH 4-#300 MCM, 1-#1/0 GRN IN EACH
2-3"C. WITH 4-#350 MCM, 1-#1 GRN IN EACH
ELECTRICAL RISER NOTES: (SOME NOTES MAY NOT BE USED)
4-#1/0, 1-#6 GRN, 2"C.
4-#1/0, 1-#6 GRN, 2"C.
4-#1, 1-#8 GRN, 1 1/2"C.
4-#3, 1-#8 GRN, 1 1/2"C.
4-#2/0, 1-#6 GRN, 2"C.
4-#3/0, 1-#6 GRN, 2"C.
4-#4/0, 1-#4 GRN, 2 1/2"C.
4-#250, 1-#4 GRN, 2 1/2"C.
4-#350, 1-#4 GRN, 3"C.
2-2"C. WITH 4-#3/0, 1-#3 GRN IN EACH
SAMPLE REDUCING PIN TERMINAL
ALL TRANSFORMERS TO BE 150°C RISE.
ALL TRANSFORMERS SERVING PANELS WITH AN ISOLATED GROUND OR
DOUBLE SIZED NEUTRAL ARE TO HAVE A RATING OF K-13 OR GREATER. ALL
OTHER TRANSFORMERS ARE TO BE RATED K-1 OR GREATER.
TRANSFORMER INFORMATION
PANEL
AL2
125
PANEL
AL
PANEL
ADP
112S
112G
TRANSFORMER112.5 KVA
TXAL112P
UTILITYTRANSFORMER
8002-4"C.
PAD MOUNTED TRANSFORMER
PROVIDED BY POWER COMPANY
POWER COMPANY
FOR COORDINATION WITH
CONTACT ONCOR
METER
PAD TO BE PROVIDED
BY CONTRACTOR
400
PANEL
AH
NEW DISCONNECT SIZED FOR
THE LOW VOLTAGE PANELS
INSIDE THE BUILDING TO BE
PROVIDED BY E.C.
400A
DISC
NEMA 3R
112S
PANEL
AL3
100
1
1
1
1
WALKWAY
10
WALKER AREA
09
SHOW RING
07STORAGE
01
MULTI-PURPOSE ROOM
02
WASHRACK
189WASHRACK
190
WASHRACK
191
RR
03
RR
04
W/H & W/D
05
OFFICE
06
TREADMILL AREA
08
ANIMAL PENS
11
LS
LS
LDLS
DE
D
D
DE
D
D DE
D DE
DD DED
D D
DDED
D D
D D DE
D
D
D3E D3D3
G2 G2 G2 G2
G2E G2 G2E G2
G2 G2
G2 G2 G2 G2
G2E G2 G2 G2E
G2 G2 G2 G2
XW
XW
XW
XW
XW
LW
LW
LS
LW
LD
LS
3
4
3
4
WP3E
WPE
WP
WPWPE
WP3
WP3
WPE
L1L1
L1
L1
L1 L1
L1
L1
LS
GE
G
G
GE
G
G
G
G
G
GE
G
G
G
G
G
GE
G G
G G
L3L3
L3
L3
L3
L3L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2
L2 L2 L2
L2 L2 L2 L2
L2 L2
L2 L2 L2 L2
L2 L2
L2 L2 L2 L2
L2 L2 L2
LW
3 LS
AH-2
AH-4
AH-8
AH-10
AH-10
AH-10
AH-10 AH-10
AH-10
AH-10
AH-10
G
G
G
G
G
G
L2
L2
L2
L2
L2
L2
G
G
G
G
G
G
L2
L2
L2
L2
L2
L2
LW d
c
d
c
4
3
dc3
LS
b
a4
ba
LS
3
LS
LW
3b
a3
LS
LW
3ba3
LS
AH-6
a
a
aa
b b b b b
b b b b
b bb
bb
b bb
bb b
b b bb
b b bb
d
c
d
d
d
c c c
c c
cc
cc cc
ccc
ccc
L5
WP2
WP2WP2
WP2
WP3
L1
AH-10
WP3
L1
AH-10
AL2-30AL2-30
AL2-30 AL2-30
LE3
L4
4ab4
LSLW
1
3LE
DE
D
DE
DL3
L4
ADP-4
Tyler | Austin | Houston | DFW | El PasoTBPE Firm Registration No. F-893www.EMAengineer.comPhone: 1 . 800 . 933 . 0538
EMA Engineering & Consulting
NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE AND WORKINGSYSTEM.
SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTING AND
DATE
JOB
SHEET
ISSUES
REVISIONS
12/9
/201
9 8
:26:0
6 A
M
EL02-01
LIGHTING FLOORPLAN
12/03/2019
19340.0000
EL02-0
1LIG
HT
ING
FLO
OR
PLA
N
CORGAN401 N. Houston StDallas, TX 75202T: 214-748-2000
2
1 12/03/2019 ISSUE FOR CONSTRUCTION
3
4
5
6
7
8
9
10
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
1/8" = 1'-0"1 LIGHTING FLOOR PLAN
REFER TO SHEET EL7-01 FOR ALL GENERAL NOTES PERTAINING TO ENTIRE DRAWING SET.
REFER TO SPECIFICATIONS, LUMINAIRE SCHEDULE, LUMINAIRE CONTROLS DETAIL, SWITCH FUNCTION DETAIL AND LIGHTING CONTROL CHART FOR ADDITIONAL REQUIREMENTS AND MORE INFORMATION.
LIGHTING GENERAL NOTES
1.
2.
INSTALL LUMINAIRE AT 7'-2" A.F.F. VERIFY EXACT INSTALLATION HEIGHT WITH ARCHITECT.
INSTALL LUMINAIRES IN THIS SPACE LEVEL WITH THE BOTTOM OF FANS. VERIFY EXACT HEIGHT WITH ARCHITECT.
INSTALL LUMINAIRES IN THIS SPACE SURFACE MOUNTED TO CEILING. INSTALL LUMINAIRES TO AVOID MECHANICAL EQUIPMENT.
3-WAY SWITCH TO CONTROL LIGHTS IN MEZZANINE.
COORDINATE SWITCH(ES) LOCATION WITH MECHANICAL CONTRACTOR.
L1
L2
LIGHTING PLAN NOTES
L3
1/8" = 1'-0"2 LIGHTING FLOOR PLAN - MEZZANINE
L4
L5
1 12/09/2019 ADDENDUM #01
WALKWAY
10
WALKER AREA
09
SHOW RING
07
STORAGE
01
MULTI-PURPOSE ROOM
02
WASHRACK
189WASHRACK
190
WASHRACK
191
RR
03
RR
04
W/H & W/D
05
OFFICE
06
TREADMILL AREA
08
ANIMAL PENS
11
22"x14"
20"ø
8"ø8"ø
14"ø
12"ø
14"x12"
10"ø
14"ø
10"ø10"ø
10"ø
8"ø
6"ø
6"ø
8"ø
BB
50 CFM
F
50 CFM
F
EF #
04
EF #03
10"ø
AC #
06
AC #
02
AH #
06
AH #
02
UH #
01
UH #02
UH #
04
UH #
03
UH #06
UH #
07UH #
08
EF #
11B
EF #
11C
EF #
11D
EF #
11A
18"x14"
UH #05
T
T
HVLS #
07
HVLS #
11F
HVLS #
11E
HVLS #
11D
HVLS #
11B
HVLS #
11A
HVLS #
11C
G
G
G
G
I
H
J
M1
M1
M2
M2M2
M2 M2 M2
M2
M3
M4
M4
M4
M4
M3
M3
M3M3
M3
M3 M3
M1
M1
M1
M1
M5
300 CFM
D
400 CFM
D
14"x12"6"ø
240 CFM
C240 CFM
C
L
L
MM
20"ø
375 CFM
K
375 CFM
K
375 CFM
K
375 CFM
K22"x14"
12"ø
ALL DUCT BELOW MEZANINE DECK TO BE DOUBLE WALL, PAINT GRIP, SPIRAL. REFER TO ARCHITECT FOR PAINT COLOR.
1
Tyler | Austin | Houston | DFW | El PasoTBPE Firm Registration No. F-893www.EMAengineer.comPhone: 1 . 800 . 933 . 0538
EMA Engineering & Consulting
NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE AND WORKINGSYSTEM.
SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTING AND
DATE
JOB
SHEET
ISSUES
REVISIONS
12/9
/201
9 8
:55:1
4 A
M
MH02-01
MECHANICALFLOOR PLAN
12/03/2019
19340.0000
MH
02-0
1M
EC
HA
NIC
AL F
LO
OR
PLA
N
CORGAN401 N. Houston StDallas, TX 75202T: 214-748-2000
2
1 12/03/2019 ISSUE FOR CONSTRUCTION
3
4
5
6
7
8
9
10
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
1/8" = 1'-0"1 MECHANICAL FLOOR PLAN
1. MECHANICAL CONTRACTOR TO PROVIDE TO THE PLUMBING CONTRACTOR THE RECOMMENDED AC MANUFACTURER'S DATA FOR CONDENSATE TRAPS PER EACH TYPE OF UNIT.
2. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OR ADJUSTMENT OF ALL HOLD DOWN BOLTS ON COMPRESSORS AT HVAC EQUIPMENT TO ALLOW FOR PROPER VIBRATION ISOLATION.
3. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL ABANDONED SCREWS, PIPING, TAPE, PAPERS, PACKING PRODUCTS, ETC.
4. ALL EQUIPMENT SHALL BE PROPERLY LABELED PER SPECIFICATIONS.
5. CLOSE ALL OUTSIDE AIR DAMPERS UPON INSTALLATION AND KEEP ALL OUTSIDE AIR DAMPERS CLOSED UNTIL THE "TEST AND BALANCE" IS PERFORMED.
6. PROVIDE AND INSTALL MANUAL VOLUME CONTROL DAMPERS ON SUPPLY AND RETURN BRANCH DUCT SERVING A DIFFUSER OR REGISTER.
7. ALL MANUAL DAMPERS INSTALLED ABOVE HARD CEILINGS OR AT OTHER INACCESSIBLE AREAS SHALL BE SUPPLIED WITH A CABLE OPERATED DAMPER EQUAL TO "YOUNG REGULATOR MODEL 830A-CC".
8. DUCT MOUNTED SMOKE DETECTORS SHALL BE FURNISHED BY THE FIRE ALARM CONTRACTOR, INSTALLED BY THE MECHANICAL CONTRACTOR, AND FINAL TIE-IN BY THE FIRE ALARM CONTRACTOR.
9. SEAL WITH FIRE RETARDING SEALANT AROUND PIPE THROUGH ANY PENETRATION OF FIRE WALLS. REFER TO ARCHITECTURAL SHEETS FOR FIRE WALLS.
10. ALL GRILLES ARE SHOWN IN APPROXIMATE LOCATION. FIELD VERIFY PLACEMENT WITH CEILING GRID.
11. ALL DIFFUSERS/FLEX CONNECTIONS SHALL HAVE A RIGID METAL ELBOW UNLESS COMING DIRECTLY DOWN FROM A UNIT OR HEIGHT OF CEILING IS EXTREME. ALL FLEX DUCT TO HAVE AT LEAST ONE SUPPORT STRAP.
12. THE SPACE AROUND DUCTS AND PENETRATING ITEMS OF SMOKE PARTITION WALLS SHALL BE FILLED WITH AN IBC APPROVED MATERIAL LIMITING THE FREE PASSAGE OF SMOKE.
13. ALL FAN CURBS TO BE INSTALLED LEVEL. PROVIDE SEAL BETWEEN CURB AND ROOF.
14. COORDINATE WITH THE PLUMBING CONTRACTOR LOCATION OF ALL SUPPLY FANS WITH PLUMBING VENTS. MAINTAIN 10'-0" MINIMUM SEPARATION.
C24. INSTALL CONDENSERS PER MANUFACTURER CLEARANCES.
C25. MECHANICAL CONTRACTOR SHALL SUBMIT TO ARCHITECT / ENGINEER REFRIGERANT LINE SET DESIGN AND ROUTING PER MANUFACTURER FOR REVIEW BEFORE INSTALLATION BEGINS.
C26. THE MECHANICAL CONTRACTOR SHALL APPLY ULTRA-VIOLET PROTECTIVE COATING OVER REFRIGERANT INSULATION PER MANUFACTURER.
C27. COORDINATE ALL UNITS, DUCTWORK, GRILLES, AND NEW REFRIGERANT LINES WITH ALL TRADES BEFORE INSTALLING.
A28. ALL HORIZONTAL AIR HANDLERS ABOVE CORRIDOR CEILINGS SHALL BE LOCATED TO POSITION SERVICE ACCESS PANEL TO FACE TOWARD CENTER OF CORRIDOR.
A29. ALL AIR HANDLERS: NO PIPING, CONDUITS, DUCTS, WIRING, DISCONNECTS, ETC. WILL BE ALLOWED TO BE INSTALLED CLOSER THAN 3'-0" (THREE FEET) IN FRONT OF THE SERVICE ACCESS PANEL.
A30. PROVIDE AND INSTALL 18 GAUGE 2" DEEP GALVANIZED DRAIN PAN UNDER EACH AIR HANDLER (PER DETAIL).
A31. ALL THERMOSTAT WIRING TO A/C UNITS SHALL BE SECURED TO REFRIGERANT LINES UTILIZING TEFLON TY-WRAPS.
P32. ALL VARIABLE FREQUENCY DRIVES (VFD'S) ARE TO BE PROVIDED BY THE MECHANICAL CONTRACTOR, INSTALLED AND POWERED BY THE ELECTRICAL CONTRACTOR, AND CONTROLLED BY THE CONTROL CONTRACTOR.
MECHANICAL GENERAL NOTESMECHANICAL PLAN NOTESKEY VALUE KEYNOTE TEXT
M1 COORDINATE EXACT HEIGHT OF OUTSIDE AIR LOUVERWITH ARCHITECT AND OWNER PREFERENCES.
M2 INSTALL HVLS FANS PER MANUFACTURERRECOMMENDATIONS.
M3 INSTALL ALL UNIT HEATERS PER MANUFACTURERRECOMMENDATIONS.
M4 COORDINATE EXACT HEIGHT OF EXHAUST FANS WITHARCHITECT AND OWNER PREFERENCES.
M5 ROUTE DRYER VENT UP IN WALL TO GOOSENECK ONROOF PER DETAIL. COORDINATE LOCATION WITH OWNERPREFERENCE FOR DRYER. SIZE VENT PERMANUFACTURER RECOMMENDATIONS 4" MINIMUM.
1 12/09/2019 ADDENDUM #01
M50506
PU
TONSMARK
NOM.MFG. USED IN DESIGN
PART NO.
CAPACITYCOOLING
(MBTUH)(KW) TOTAL SENS.
INPUT
HEAT
AH
UNIT
WEIGHTS (LB.)REMARKS:
SEER / EER AFTERE.S.P.
COIL AC
MOP
MOCP
AH AC
ELECTRICAL
DATA
AH AC
HEAT
(MBTUH)OUTPUT
AUX.
PROVIDE
LOWSPEED
CFM
HIGHSPEED
CFM
(SPLIT SYSTEM - HEAT PUMP)A/C SCHEDULE
MARKCFM
DATAACCESSORIES:PROVIDESONES
H.P./WMOTOR
MODELMANUFACTURER
CONTROL
FAN SCHEDULE
DESCRIPTION REMARKS: PROVIDENECKFINISHMODELXX
GRILLE SCHEDULE
UH # 01, 02, 03, 04, 05, 07, 08
@ 480V MOUNTING BRACKET, FAN TIME DELAY SWITCH
30.0 SUMMER/WINTER SWITCH, UNIT MOUNT THERMOSTAT,2100/1800 480V., 3PH40HUHAA-3048
BERKO
MOUNT AT 9'-0" AFF. MIN.
1/4
NOTE: UNITS RECEIVING IONIZER SHALL HAVE 2 POSITION DAMPERS(OPEN AND CLOSED)
AH/AC #06 BASED ON OUTDOOR AIR TEMPERATURE OF 17°F HEATING AND 80°F DB/67°F WB - 105°F AMBIENT.OUTSIDE AIR DAMPER PROVIDED BY CONTROLS CONTRACTOR AND INSTALLED BY THE MECHANICAL CONTRACTOR
AH/AC #02
EF #03, 04
NOTE: ALL SIDEWALL GRILLES/LOUVERS SHALL HAVE EXACT LOCATION AND HEIGHT VERIFIED WITH ARCHITECT BEFORE INSTALLING.
EF #11A, 11B, 11C, 11D
HVLS # N/A
HVLS #07, 11A, 11B, 11C, 11D, 11E, 11F
PLASMA AIR7100
BULB-LESS DESIGN, 24V POWER.
PLASMA AIR7200
BULB-LESS DESIGN, 24V POWER.
1.5 - 3.0
4.0 & 5.0
REMARKS: ALL REMARKS MAY NOT BE USED PER EACH UNIT. VERIFY WITH REMARKS COLUMN.1. FILTERS/RACK2. HAIL COIL GUARD3. THERMAL EXPANSION VALVE4. R410-A
5. UNITS 3 TO 5 TONS: TWO STAGE COMPRESSORS6. ECONOMIZER MODE WITH FDD
7. MOTORIZED OUTSIDE AIR DAMPER.
LENNOX
O/ACFMMAX
O/ACFMMIN
-
A75.25
60 WCOOK
GC-240120 V.,1 ph. 1.3 LIGHTS
FACTORY INSTALLED SPEED CONTROLLER,GEMINI DELUXE ALUMINUM GRILLE - WHITE
BCEILING RETURNGRILLE
PRICE80
WHITE22" x 22"
MODULE SIZE 24x24,(FLUSH MOUNT ADD TRIM FRAME AND ADJUSTABLE DAMPER)
GOUTSIDE AIRINTAKE LOUVER
POTTORFFEBE-445
BAKEDENAMEL
48" x 42"MOTORIZED DAMPER TO CLOSE WHEN UNIT IS OFF,COLOR TO BE DETERMINED BY ARCHITECT/OWNER
JEXHAUSTLOUVER
POTTORFFEFD-445
BAKEDENAMEL
18" x 12"BACKDRAFT DAMPER,COLOR TO BE DETERMINED BY ARCHITECT/OWNER
D..
1.5 HPBIG ASS FAN
POWERFOIL X 3.0208 V., 1 ph. . SWITCH
12'-0", WALL KEYPAD, MOUNTING KIT, COLOR BY ARCH,MANUFACTURER CONTROL BOX W/ VFD, CONTROL RELAY
C..
1.0 HPBIG ASS FAN
POWERFOIL X 3.0208 V., 1 ph. . SWITCH
8'-0", WALL KEYPAD, MOUNTING KIT, COLOR BY ARCH,MANUFACTURER CONTROL BOX W/ VFD, CONTROL RELAY
B36000.25
0.41 HPCOOK
24XW32D17 (VF)120 V., 1 ph. 13.9 SWITCH
WIRE GUARD, WALL COLLAR, WEATHER HOOD,STANDARD WALL SHUTTER, INTERLOCK WITH LOUVER
ACEILING SUPPLYDIFFUSER
PRICESCD
WHITE12" dia.
MODULE SIZE 24x24,(FLUSH MOUNT ADD TRIM FRAME AND ADJUSTABLE DAMPER)
EEXHAUSTRELIEF
COOKPR12
ALUM.PER PLANS
ROOF CURB,BACKDRAFT DAMPER, MIN. SIZE 12"x12"
HOUTSIDE AIRINTAKE LOUVER
POTTORFFEBE-445
BAKEDENAMEL
48" x 24"MOTORIZED DAMPER TO CLOSE WHEN UNIT IS OFF,COLOR TO BE DETERMINED BY ARCHITECT/OWNER
IOUTSIDE AIRINTAKE LOUVER
POTTORFFEBE-445
BAKEDENAMEL
24" x 24"MOTORIZED DAMPER TO CLOSE WHEN UNIT IS OFF,COLOR TO BE DETERMINED BY ARCHITECT/OWNER
B 5.0 1990 1600 320 0AIR HANDLER - CBA27UHE-060-G
CONDENSER - TPA-060H4-460 480V., 3ph 480V., 1ph 30 15 15.0 / - 32.015.0
@ 480V., 3ph.52.9 37.9 .5 200 375
1, 2, 3, 4, 5, 6, 7
A 2.0 800 550 160 0AIR HANDLER - CBA27UHE-024
CONDENSER - XP16-024-230 208V., 1ph 208V., 1ph 35 20 14.0 / - 15.36.0
@ 208V.20.6 11.4 .5 140 225
1, 2, 3, 4, 5, 6, 7
DROUND CEILINGDIFFUSER
PRICERCDE
WHITE10" dia.
OPPOSED BLADE DAMPER,(FLUSH MOUNT ADD TRIM FRAME AND ADJUSTABLE DAMPER)
KDRUM LOUVERDIFFUSER
PRICEHCD1
WHITE18" x 6"
OPPOSED BLADE DAMPER, GRILLE AT 30° ANGLE,PLENUM TAP TO MATCH GRILLE SIZE
CROUND CEILINGDIFFUSER
PRICERCDE
WHITE8" dia.
OPPOSED BLADE DAMPER,(FLUSH MOUNT ADD TRIM FRAME AND ADJUSTABLE DAMPER)
FROUND CEILINGDIFFUSER
PRICERCDE
WHITE6" dia.
OPPOSED BLADE DAMPER,(FLUSH MOUNT ADD TRIM FRAME AND ADJUSTABLE DAMPER)
LSPIRAL DUCT RETURNDIFFUSER
PRICESDGER
WHITE14" x 12"
PLENUM TAP TO MATCH GRILLE SIZE
MSPIRAL DUCT RETURNDIFFUSER
PRICESDGER
WHITE12" x 6"
PLENUM TAP TO MATCH GRILLE SIZE
(ELEC.)
KW REMARKS:PROVIDEH.P.
SYSTEMC.F.M.
MOTOR ELECTRICALDATA
AMPSMARKMFG. USED IN DESIGN
PART NO.
UNIT HEATER SCHEDULE
AIR IONIZER SCHEDULE
MANUFACTURERSPLIT SYSTEMS REMARKS
TONS MODEL #
A
A
A
B
A
B
C
D
Tyler | Austin | Houston | DFW | El PasoTBPE Firm Registration No. F-893www.EMAengineer.comPhone: 1 . 800 . 933 . 0538
EMA Engineering & Consulting
NEW WORK REQUIRED FOR INSTALLATION OF A COMPLETE AND WORKINGSYSTEM.
SUBMISSION OF BID WILL BE CONSIDERED ACKNOWLEDGMENT THAT THE
CONTRACTOR HAS VISITED THE SITE AND HAS VERIFIED ALL EXISTING JOBCONDITIONS AND INCLUDED ANY NECESSARY MODIFICATION TO EXISTING AND
DATE
JOB
SHEET
ISSUES
REVISIONS
12/9
/201
9 8
:55:1
4 A
M
MH08-01
MECHANICALSCHEDULE
12/03/2019
19340.0000
MH
08-0
1M
EC
HA
NIC
AL S
CH
ED
ULE
CORGAN401 N. Houston StDallas, TX 75202T: 214-748-2000
2
1 12/03/2019 ISSUE FOR CONSTRUCTION
3
4
5
6
7
8
9
10
AG
SC
IEN
CE
PR
OJE
CT
CE
NT
ER
154
Lo
uis
e R
itte
r B
lvd,
Re
d O
ak,
TX
75
15
4
1 12/09/2019 ADDENDUM #01
1