6
Whitlam Housing Development Guide – Stage 1 Suburban Land Agency – 470 Northbourne Avenue, Dickson ACT 2602 GPO BOX 158, Canberra ACT 2016 | P: 02 6205 0600 | E: [email protected] Annexure C - Block Details Plans Below are the Block Details Plans for Whitlam Stage 1 - Sections 4,5,6,13,14 & 15.

Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

Whitlam Housing Development Guide – Stage 1

Suburban Land Agency – 470 Northbourne Avenue, Dickson ACT 2602 GPO BOX 158, Canberra ACT 2016 | P: 02 6205 0600 | E: [email protected]

Annexure C - Block Details Plans

Below are the Block Details Plans for Whitlam Stage 1 - Sections 4,5,6,13,14 & 15.

Page 2: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

THIS PAGE IS INTENTIONALLY LEFT BLANK

Page 3: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

Z

Z Z

Z

Z

Z

Z

Z

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

##

##

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

M

M

M

M

M

*

*

2ST

2ST

2ST

*

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

M

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0 6.0 6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0

6.0

Z

Z

MM

M

M

/

ROA

D0

4

R

O

A

D

0

4

RO

AD

35

RO

AD

34

R

O

A

D

0

6

RO

AD

06

R

O

A

D

0

5

R

O

A

D

0

4

R

O

A

D

0

1

504m² 425m² 425m² 538m²

674m²

638m²

637m²

639m²

637m²

552m²

558m²

558m²

558m²

643m²

501m²

501m²

501m²

562m²

569m²

577m²

580m²

592m²

643m²

651m²

651m²

651m²

604m²

438m²

498m²

462m²

465m²

542m² 625m²

565m²

566m²

571m²

572m²

575m²

550m²

527m²

558m²

651m²

643m²

279m² 246m² 246m² 241m² 241m² 248m² 241m² 291m² 290m² 243m² 241m² 241m² 248m² 241m² 248m²294m²

270m² 244m² 244m² 244m² 243m² 244m² 270m² 273m² 286m² 240m² 240m² 244m² 244m² 243m²312m²

489m²505m²

442m²516m²

444m²

573m²

558m²

558m²

569m²555m²

594m²559m²

481m²555m²

567m²617m²

587m² 563m²

602m²651m²

778m²

6.1

5.45.5

7.5

5.6

5.6

26.2

A20.5

A17.8

25.9

20.9

3

2.9

2.83

6.7

30.5

31.2

30.7

31.4

31.5

30.9

30.2

30.1

30

30.1

30.4

30.3

1.5

17

17

3030

30.8

29.9

30.2

30.2

30.5

30.4

30.9

30.3

31.2

30.6

31.4

6.5

6.9

30.8

29.9

30.8

8

19.6

21.2

4.6

2.2

14.4

11.2

5.7

0.5

10

7.5

5.7

5.7

31

31

31

31

31

31

5.7

31

31

31

31

31

31

31

3127

A12.5

A11.9

A7.1

A8.2

A8

A12.5A7.1

6.6

A23.1

A23

A23.1

A23

A7.5

20.5

18

17177

17

17

17.3

17.3

29.7

17

1711.2

17

1710.7

17

10.3

5.2

8.3

27272727

27272727272727272727272727

2727

272727272727 27

2727

11.5

18

14

31.8

18.7

32.1

3231.7

31.3

30.9

30.9

30.830.8

30.330.3

30.5

18.7

17.3

3.318

9.7

18

27

A14

A14

A15

A13

A15.8

1.5A1

3.8A1

5

A15

A15

18

18

18

17

18

18

18

29

21

21

21

21

17

16.2

16.2

16.2

1.4

16.7

17

18

21

17

17

18

21

21

21

21

A8.8 A8.8 A8.8A9 A8.8 A8.8 A8.8 A9 A8.5

A8.9 A8.9 A8.9 A8.8 A8.9 A10 A9.8 A10.1 A8.9 A8.9 A8.9 A8.9 A8.9 A7.1

A9.1 A9.1 A9.1 A11 A9 A9.1 A9.1 A9.3 A9.1A7.1

A14 A14 A15

A9.2 A9.2 A9.2A8.9 A8.9

A9.1 A9

31

31

13.9

9.2

2.8

A19.8

A19.8

A19.9

A11.1

A18

A18

A18.3

A15

A19

A17.5

A19.1

A19

A19.1

A18.7

A19.4

A19

13.6

27

31

A11.1A9.2 A9.2 A9.2 A10.9

A8.5

A19.4

A14

15.8

3

20

11

10

14.5

A19.9

A19.8

16.8

15.9

21

21

A11.9

17.8 1431.3

14.7

6.5

18

12.8

17

16.2

16.2

16.2

A16.8

A9.2 A9.3 A9.3 A11.1

A9.3

A9 A10.6 A10.4A9

A9.2 A9.2 A10 A10.5

5.85.4

6.24.9

16.9A9

.9

A28.2 A25.9A26.7

A25.8

10.9

14.2

15.7

16

27.1

2

3

4

5

6

3

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

7654321

14131211109815

21

22

23

1 2 3

6

4

5

15

16

17

18

19

12

13

14

20

8

9

10

11

7

2

3

4

5

6

18

19

20

21

1

7

8

9

10

11

15

16

17

13

14

1

27

26

25

24

23

2

3

4

5

6

7

8

9

10

22

21

20

19

1

580.0

585.0

590.0

585.0

590.0

590.0

595.0

589.0

592.0

588.0

592.0594.0

587.0

589.0

593.0

591.0

588.0

583.0

583.0

585.0

M

BLOCK IDENTIFIER

SECTION IDENTIFIER

BLOCK DIMENSIONS (m)

BLOCK AREA (m²)

DRIVEWAY LOCATION

STREET LIGHT

UTILITY MAINTENANCE ACCESS EASEMENT

STORMWATER AND SEWER EASEMENT

FOOTPATH

ESTATE BOUNDARY

INDICATIVE TREE LOCATIONS

Z

LEGEND

1. CONTOUR INTERVAL IS 1m. CONTOURS REPRESENTS PRELIMINARY DESIGNCONTOURS AND MAY BE SUBJECT TO CHANGE, LEVELS SHOULD BE VERIFIEDBY LESSEES

2. PLAN SUBJECT TO SURVEY- FINAL DIMENSIONS, AREAS & BLOCK NUMBERSTO BE OBTAINED FROM DEPOSITED PLANS.

3. REFER TO HOUSING DEVELOPMENT GUIDELINES FOR DETAILS OF;· MAXIMUM RETAINING WALL HEIGHTS.· MAXIMUM LEVEL CHANGES.· SDHDC = SINGLE DWELLING HOUSING DEVELOPMENT CODE

DISCLAIMERTHE SUBURBAN LAND AGENCY MAKES NO WARRANTY REGARDING THEACCURACY OR COMPLETENESS OF INFORMATION ON THIS PUBLICATION ANDRECOMMENDS OBTAINING INDEPENDENT LEGAL ADVICE BEFORECONSIDERING PURCHASING LAND OR MAKING AN OFFER TO PURCHASELAND.

651m²

31

2

1

MID SIZE CODE APPLIED TO THESE BLOCKS (500m2-<550m²) (FORTHE PURPOSE OF R21 OF THE SDHDC)

MANDATORY HABITABLE ROOM ABOVE GARAGE

*

#

FACADES FACING JOHN GORTON DRIVE AND WILLIAM HOVELL DRIVEREQUIRE ACOUSTIC PROTECTION MEASURES TO ADDRESSEXTERNAL ROAD NOISE. REFER TO SDHDC FOR DETAILS.

MANDATORY 2 STOREY BUILT FORM2ST

STAGE BOUNDARY

BLOCKS OVER 500m2 - SIDE SETBACKS ARE MINIMUM 3.0m AND1.5m FOR GARAGE. NO ZERO SETBACK (PROVISION OF R14SDHDC DOES NOT APPLY)

MANDATORY COURTYARD WALL TO MAX HEIGHT OF 1.5m ,CONSTRUCTED OF RENDERED BRICK, BLOCK OR STONEWORK INCOMBINATION WITH FEATURE PANELS, AND SETBACK 600m FROMTHE FRONT BOUNDARY TO INCORPORATE LANDSCAPING, REFER TODRAWING PCP1, DETAIL-1, TYPE 1 & TYPE 2 COURTYARD WALLALONG SECONDARY FRONTAGE TO TERMINATE @ 5m FROMPRIMARY FRONTAGE

INTEGRATED HOUSING DEVELOPMENT

LIMITED DEVELOPMENT POTENTIAL BLOCK(R.49 ESTATE DEVELOPMENT CODE)

567.0

NOTES

MANDATORY ZERO SETBACK (NOMINATED AS SIDE BOUNDARY 2FOR THE PURPOSE OF R15 OF SDHDC)

6.0MINIMUM BUILDING HEIGHT ( IN METRES) ALONGTHE PRIMARY BLOCK FRONTAGES FOR ACOUSTICPROTECTION OF 1 OR 2 STOREY BUILT FRONT

BUS STOP PAD

DESIGN CONTOUR (@ INTERVAL 1m)

DATE

AMENDMENT DETAILS

APPROVEDCHECKDRAWN

N

E

M

A

ISSUE

FIRST

DESIGN

N

E

M

S

T

D

DRAWING No. REVISIONPROJECT No.

PROJECT DRAWING TITLESTATUS SCALE WAE No.

DISCLAIMERALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTORPRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DONOT SCALE. NOT FOR CONSTRUCTION UNLESS STAMPED BYCERTIFYING AUTHORITY

Authorised for Issue:

SIGN: DATE:

BY:

CLIENT

calibregroup.comC

0 5 10 15 20 25 30 35 40

SCALE 1:1000 (A3)SCALE 1:500 (A1)

N

16-003589 2000

BLOCK DETAILS PLAN

SHEET 1 OF 13

WHITLAM ESTATE STAGE 1

----

DETAIL DESIGN----JW JW 26/02/2020

Page 4: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

Z

Z

Z

Z Z

Z

Z

Z

Z

Z

Z

Z

Z

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

#

M

2ST

2ST

2ST

2ST

2ST

2ST

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

ZZ

Z

Z

Z

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

6.0

M

M

M

R

O

A

D

0

6

R

O

A

D

0

5

R

O

A

D

0

4

R

O

A

D

1

0

R

O

A

D

1

1

R

O

A

D

0

9

RO

AD

0

7

R

O

A

D

0

1

R

O

A

D

0

1

R

O

A

D

0

1

MU (2 to 3)

558m²

558m²

643m²

643m²

651m²

651m²

651m²

604m²

438m²

572m²

575m²

550m²

527m²

558m²

651m²

643m²

569m²555m²

594m²559m²

481m²555m²

567m²617m²

587m² 563m²

602m²651m²

650m²

651m²

651m²

651m²

651m²

643m²

643m²

644m²

643m²

567m²

567m²

567m²

567m²

567m²

701m²

660m²

1027m²

802m²

683m²

652m²

652m²

592m²

632m²

576m²

540m²

774m²

576m²

826m²548m²632m²

486m²

451m²

723m²

613m²

778m²

1010m²

12.9

4.3

15.1

30.5

31.2

30.7

31.4

31.5

30.9

30.1

30

30.1

30.4

30.3

17

17

31.8

20.9

18.530

42.9

33.6

30.4 30.6

31.4

30.8

16

5.7

21

19.4

5.721

17

5.7

32

11.5

5.714

.5

A15.9

2.2

5.7

A2.9

16

A12.5

0.5

5.7

10

7.5

5.7

17

5.720

31.1

31

31

31

31

31

31

27

5.7

32

32

32

28

5.7

31

31

31

31

27

5.7

31

31

31

31

31

31

27

5.7

31

31

31

3127

5.7

13.9

5.7

31.5

20

16

26.1 2.2

12.3

20.5

18

17177

17

17

17

1711.2

18.7

A15.8

18.717.9

A18.2

18

15.3

A8.6

18

18

18

17

18

29

21

21

21

21

17

21

21

18

18

11.7

18

18

15.3

21

21

4.7

17

18

21

17

17

17

18

21

21

21

21

21

17

31

27

31

31

31

31

26

30

30

27.1

31.1

A19.9

A11.1

A18

A18.3

A15

A19

A17.5 A1

8.7

A19.4

A19

A20.4

A1.6

13.6

27

31

35.9

33.3

33.8

3

20

11

10

14.5

A19.9

A19.8

15.9

21

21

16.2

A16.8

A14.2

38.8

21

21

A11.4

7.516.1

A3.8

18.3

18.3

18.3

18.3

18.3

18.3

18.3

26.2

18.3

26.1

18.3

18.319

21

21

17

21

A27

14.5

28

15.8

31.621.3

16

13.6

29

27.1

4.8 19.618.7 2.1

26.4

12.6

A6.3A24.9

4

5

7

9

8

7

15 12

13

14

5

6

7

8

9

10

11

15

16

17

12

13

14

24

23

7

8

9

10

22

21

20

11

12

13

15

19

18

17

16

14

1

2

3

4

5

6

3

7

910

11

1

8

2

5

6

7

8

9

10

11

12

1

18 2

3

4

13

590.0

595.0

588.0

592.0594.0

587.0

585.0

585.0

595.0

595.0

590.0

587.0

589.0

590.0

M

BLOCK IDENTIFIER

SECTION IDENTIFIER

BLOCK DIMENSIONS (m)

BLOCK AREA (m²)

DRIVEWAY LOCATION

STREET LIGHT

UTILITY MAINTENANCE ACCESS EASEMENT

STORMWATER AND SEWER EASEMENT

FOOTPATH

ESTATE BOUNDARY

INDICATIVE TREE LOCATIONS

Z

LEGEND

1. CONTOUR INTERVAL IS 1m. CONTOURS REPRESENTS PRELIMINARY DESIGNCONTOURS AND MAY BE SUBJECT TO CHANGE, LEVELS SHOULD BE VERIFIEDBY LESSEES

2. PLAN SUBJECT TO SURVEY- FINAL DIMENSIONS, AREAS & BLOCK NUMBERSTO BE OBTAINED FROM DEPOSITED PLANS.

3. REFER TO HOUSING DEVELOPMENT GUIDELINES FOR DETAILS OF;· MAXIMUM RETAINING WALL HEIGHTS.· MAXIMUM LEVEL CHANGES.· SDHDC = SINGLE DWELLING HOUSING DEVELOPMENT CODE

DISCLAIMERTHE SUBURBAN LAND AGENCY MAKES NO WARRANTY REGARDING THEACCURACY OR COMPLETENESS OF INFORMATION ON THIS PUBLICATION ANDRECOMMENDS OBTAINING INDEPENDENT LEGAL ADVICE BEFORECONSIDERING PURCHASING LAND OR MAKING AN OFFER TO PURCHASELAND.

651m²

31

2

1

MID SIZE CODE APPLIED TO THESE BLOCKS (500m2-<550m²) (FORTHE PURPOSE OF R21 OF THE SDHDC)

MANDATORY HABITABLE ROOM ABOVE GARAGE

*

#

FACADES FACING JOHN GORTON DRIVE AND WILLIAM HOVELL DRIVEREQUIRE ACOUSTIC PROTECTION MEASURES TO ADDRESSEXTERNAL ROAD NOISE. REFER TO SDHDC FOR DETAILS.

MANDATORY 2 STOREY BUILT FORM2ST

STAGE BOUNDARY

BLOCKS OVER 500m2 - SIDE SETBACKS ARE MINIMUM 3.0m AND1.5m FOR GARAGE. NO ZERO SETBACK (PROVISION OF R14SDHDC DOES NOT APPLY)

MANDATORY COURTYARD WALL TO MAX HEIGHT OF 1.5m ,CONSTRUCTED OF RENDERED BRICK, BLOCK OR STONEWORK INCOMBINATION WITH FEATURE PANELS, AND SETBACK 600m FROMTHE FRONT BOUNDARY TO INCORPORATE LANDSCAPING, REFER TODRAWING PCP1, DETAIL-1, TYPE 1 & TYPE 2 COURTYARD WALLALONG SECONDARY FRONTAGE TO TERMINATE @ 5m FROMPRIMARY FRONTAGE

INTEGRATED HOUSING DEVELOPMENT

LIMITED DEVELOPMENT POTENTIAL BLOCK(R.49 ESTATE DEVELOPMENT CODE)

567.0

NOTES

MANDATORY ZERO SETBACK (NOMINATED AS SIDE BOUNDARY 2FOR THE PURPOSE OF R15 OF SDHDC)

6.0MINIMUM BUILDING HEIGHT ( IN METRES) ALONGTHE PRIMARY BLOCK FRONTAGES FOR ACOUSTICPROTECTION OF 1 OR 2 STOREY BUILT FRONT

BUS STOP PAD

DESIGN CONTOUR (@ INTERVAL 1m)

DATE

AMENDMENT DETAILS

APPROVEDCHECKDRAWN

N

E

M

A

ISSUE

FIRST

DESIGN

N

E

M

S

T

D

DRAWING No. REVISIONPROJECT No.

PROJECT DRAWING TITLESTATUS SCALE WAE No.

DISCLAIMERALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTORPRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DONOT SCALE. NOT FOR CONSTRUCTION UNLESS STAMPED BYCERTIFYING AUTHORITY

Authorised for Issue:

SIGN: DATE:

BY:

CLIENT

calibregroup.comC

0 5 10 15 20 25 30 35 40

SCALE 1:1000 (A3)SCALE 1:500 (A1)

N

JW JW 26/02/2020

16-003589 2001

BLOCK DETAILS PLAN

SHEET 2 OF 13

WHITLAM ESTATE STAGE 1

----

DETAIL DESIGN----

JOHN GORTON DRIVE

Page 5: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

Z

Z Z

Z

Z

M

M

#

#

#

#

#

#

##

#

#

#

#

M

M

MM

*

*

#

*

#

#

Z

Z

Z

Z

Z

Z

Z

Z

Z

Z

6.0

6.06.0

6.06.0 6.0 6.0 6.0 6.0 6.0 6.0

6.06.0

6.0 6.0

Z

M

RO

AD

0

7

R

O

A

D

0

1

R

OA

D

01

ROAD 39

R

O

A

D

0

8

ROAD16

R

O

A

D

1

6

A

R

O

A

D

1

6

ROAD15

RO

AD

1

4

RO

AD

1

3

RO

AD

08

MU (2 to3)

BULK WATER SUPPLY MAIN EASEMENT 20m W

IDE

EASE

MENT

20m

WID

E

BULK

WAT

ER S

UPPL

Y MA

IN

526m²

399m²

399m²401m²

399m² 399m²431m² 180m² 434m² 393m² 393m² 395m²

393m²480m²

441m²

448m²

462m²340m² 346m² 309m² 310m² 311m² 312m² 347m² 350m²

459m²

707m²

594m²

466m²

522m²420m²

420m²

570m²

570m²

450m²

420m²

420m²

420m²

569m²539m²

459m²

420m²

510m²420m²

420m²420m²

420m² 420m²

390m² 390m²

465m² 465m²

629m²

569m²

596m²

488m²583m²

435m² 450m²

450m²435m²

435m² 450m²

435m² 450m²

435m² 450m²

493m² 510m²

493m² 510m²

85m²

1171m²

1196m²

A5.7 23.2

14

6

7

5.8

6.1

2.8

2.9

2.9

2.9

5.9

6.1

29.3

20.5

29

29.1

14.9

29

29

29

29

29

29

29

30

30

30

30

30

30

30

30

30

30

30

30

30

30

30

30

30

30

30

A17.6

A22.7

A13.3

18.6

5.7

30

30

30

15 15

5.711

.5

A23.5

A12.7

4.3

A24.3

23.7

A8.2

A11.7

A9

A15.5

25.8

A9.7 A9.4 A10 A10 A10 A10.1 A9.6 A10.1 A10.430.6

3131.231

.331.2313130.930.6

30.7

30

30

303030

3030303030

10

9.7

A14A10.6

30

30

30

30

30

30

30

30

30

18

30

30

30

A13.9 A14 A13.9A14

A16A12.5

A12.5A12.6 A12.5 A12.5 A13.5 A6 A13.2 A12.3 A12.3 A12.4 A12.3 A12.5

A12.5 A13.1 A10 A10 A10 A10.1 A12.7 A12.5 A14.4

A28.2

A14.1A14.1

A14.2A14.1 A14.1 A15.3 A6 A15.8 A13.9

38.5

18

60

1519

19

21.3

7.7

11.4

4.6

5.85.9

4.9

A26.1A26

15.5

15.5

10.7

15.5

A30.8

A28.3

1919

15

1714

1413

1417 14

1414

13

A25

7.1

0.9

1414

1414

14

17.4

1414

1414

1414

1515

1515

1517

17

1515

15

15

1717

14.5

1515

1515

1717

1414

1414

13

28.2

30.1

10.7

17.1

14

510m²1710

.8A1

3.5A6

.6

17.4

16.2

15.3

A20

29.7

4.826

.4

10.7

7.3

A17

15.6

17

30

15.3

4.3

11

13

15

1616

16

14

15

14

13

12 17

1811

10 19

209

8 21

227

6 23

245

10 7

9 8

1

2

314

13 4

12 5

611

7654321

109

82

1

3

4

56

78 9 10 11 12

1314

15

16

17

10

9

8

7

6

5

15

16

17

18

11

12

13

14

16

570.0

575.0

580.0

575.0

580.0

580.0

580.0

585.0585.0

585.0

585.0

M

BLOCK IDENTIFIER

SECTION IDENTIFIER

BLOCK DIMENSIONS (m)

BLOCK AREA (m²)

DRIVEWAY LOCATION

STREET LIGHT

UTILITY MAINTENANCE ACCESS EASEMENT

STORMWATER AND SEWER EASEMENT

FOOTPATH

ESTATE BOUNDARY

INDICATIVE TREE LOCATIONS

Z

LEGEND

1. CONTOUR INTERVAL IS 1m. CONTOURS REPRESENTS PRELIMINARY DESIGNCONTOURS AND MAY BE SUBJECT TO CHANGE, LEVELS SHOULD BE VERIFIEDBY LESSEES

2. PLAN SUBJECT TO SURVEY- FINAL DIMENSIONS, AREAS & BLOCK NUMBERSTO BE OBTAINED FROM DEPOSITED PLANS.

3. REFER TO HOUSING DEVELOPMENT GUIDELINES FOR DETAILS OF;· MAXIMUM RETAINING WALL HEIGHTS.· MAXIMUM LEVEL CHANGES.· SDHDC = SINGLE DWELLING HOUSING DEVELOPMENT CODE

DISCLAIMERTHE SUBURBAN LAND AGENCY MAKES NO WARRANTY REGARDING THEACCURACY OR COMPLETENESS OF INFORMATION ON THIS PUBLICATION ANDRECOMMENDS OBTAINING INDEPENDENT LEGAL ADVICE BEFORECONSIDERING PURCHASING LAND OR MAKING AN OFFER TO PURCHASELAND.

651m²

31

2

1

MID SIZE CODE APPLIED TO THESE BLOCKS (500m2-<550m²) (FORTHE PURPOSE OF R21 OF THE SDHDC)

MANDATORY HABITABLE ROOM ABOVE GARAGE

*

#

FACADES FACING JOHN GORTON DRIVE AND WILLIAM HOVELL DRIVEREQUIRE ACOUSTIC PROTECTION MEASURES TO ADDRESSEXTERNAL ROAD NOISE. REFER TO SDHDC FOR DETAILS.

MANDATORY 2 STOREY BUILT FORM2ST

STAGE BOUNDARY

BLOCKS OVER 500m2 - SIDE SETBACKS ARE MINIMUM 3.0m AND1.5m FOR GARAGE. NO ZERO SETBACK (PROVISION OF R14SDHDC DOES NOT APPLY)

MANDATORY COURTYARD WALL TO MAX HEIGHT OF 1.5m ,CONSTRUCTED OF RENDERED BRICK, BLOCK OR STONEWORK INCOMBINATION WITH FEATURE PANELS, AND SETBACK 600m FROMTHE FRONT BOUNDARY TO INCORPORATE LANDSCAPING, REFER TODRAWING PCP1, DETAIL-1, TYPE 1 & TYPE 2 COURTYARD WALLALONG SECONDARY FRONTAGE TO TERMINATE @ 5m FROMPRIMARY FRONTAGE

INTEGRATED HOUSING DEVELOPMENT

LIMITED DEVELOPMENT POTENTIAL BLOCK(R.49 ESTATE DEVELOPMENT CODE)

567.0

NOTES

MANDATORY ZERO SETBACK (NOMINATED AS SIDE BOUNDARY 2FOR THE PURPOSE OF R15 OF SDHDC)

6.0MINIMUM BUILDING HEIGHT ( IN METRES) ALONGTHE PRIMARY BLOCK FRONTAGES FOR ACOUSTICPROTECTION OF 1 OR 2 STOREY BUILT FRONT

BUS STOP PAD

DESIGN CONTOUR (@ INTERVAL 1m)

DATE

AMENDMENT DETAILS

APPROVEDCHECKDRAWN

N

E

M

A

ISSUE

FIRST

DESIGN

N

E

M

S

T

D

DRAWING No. REVISIONPROJECT No.

PROJECT DRAWING TITLESTATUS SCALE WAE No.

DISCLAIMERALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTORPRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DONOT SCALE. NOT FOR CONSTRUCTION UNLESS STAMPED BYCERTIFYING AUTHORITY

Authorised for Issue:

SIGN: DATE:

BY:

CLIENT

calibregroup.comC

N

JW JW 26/02/2020

16-003589 2003

BLOCK DETAILS PLAN

SHEET 4 OF 13

WHITLAM ESTATE STAGE 1

----

DETAIL DESIGN----

0 5 10 15 20 25 30 35 40

SCALE 1:1000 (A3)SCALE 1:500 (A1)

Page 6: Annexure C - Block Details Plans...20 31.1 31 31 31 31 31 31 27 5.7 32 32 32 28 5.7 31 31 31 31 27 5.7 31 31 31 31 31 31 27 5.7 31 31 31 31 27 5.7 13.9 5.7 31.5 20 16 26.1 2.2 12.3

Z

Z

Z Z

Z

M

M

M

M

M

M

M

MM

M

M

M

M

Z

Z

Z

Z

Z

Z

Z

Z

Z

ZZ

Z Z

Z

Z Z

Z Z

Z

M

/

/

/

RO

AD

0

7

ROAD 39

R

O

AD

44

RO

AD

1

4

RO

AD

1

3

RO

AD

0

8

R

O

A

D

1

6

ROAD15

R

O

A

D

1

2

RO

AD

1

4

RO

AD

1

3

RO

AD

08

BULK WATER SUPPLY MAIN EASEMENT 20m W

IDE

448m²

707m²

594m²

466m²

522m²420m²

420m²

570m²

570m²

450m²

450m²

420m²

540m² 540m²

420m²

420m²

420m²

420m²

420m²

420m²

600m²

540m² 540m²

569m²539m²

459m²

420m²

510m²420m²

420m²420m²

420m² 420m²

390m² 390m²

465m² 465m²

297m

²

175m

²

175m

²

175m

²

227m

²

227m

²

175m

²

175m

²

175m

²

297m

²

600m²

350m

²

205m

²

202m

²

207m

²

246m

²

249m

²

188m

²

185m

²

182m

²

310m

²

596m²

488m²583m²

435m² 450m²

450m²435m²

435m² 450m²

435m² 450m²

435m² 450m²

493m² 510m²

493m² 510m²

522m² 540m²

590m²

522m² 540m²

622m²

654m²

738m²

1171m²

478m²

469m²

590m²

4.614

32.1

30

30

30

30

30

30.2

6.1

2.8

2.9

6.1

29.1

14.9

28.9

29

29

29

29

29

29

29

29

29

29

29

30

30

30

30

30

30

30

30

8.5

8.5

8.5

30

30

30

30

30

30

30

30

30

30

30

30

30

30

A17.6

A22.7

9.8

29.8

32.3

29.8

30.4

A13.5

10

18

1518

35 35 35 35 35 35

41.4

40.8

40.2

39.5

38.7

37.9

3537

.335

36.7

3536

.1

15

A23.5

A12.7 A9.7 A9.4 A10 A10 A10.1 A9.6 A10.1 A10.4

A9.5 A19.9

A21

57.7

24.86.2

30.6

A10.6

30

30

30 5556.56.35.2

30

30

30

30

30

30

30

30

30

30

30

30

30

5556.56.35.25

558.5

5556.56.55558.5

5556.56.55558.5

30

30

30

1818 14 A17.6

A14.9

18

59

59

60

60

60

60

1519

1519

A17.9

A4.4

4.6

5.85.9

4.9

A26.1 A26

15.5

15.5

10.7

15.5

A30.8

A28.3

1919

1515

14

1714

1413

3510

22.5

1417 14

1414

13

0.912

.1

1414

1414

1414

1414

1810

8.5

17.4

1414

1414

1414

1414

18

3510

14

1515

1515

1517

1718

1018

16.5

1515

15

15

1717

18

1515

1515

1717

1810

183.6

1414

1414

13

28.2

30.1

10.7

17.1

14

510m²1710

.8A1

3.5A6

.6

17.4

16.2

15.3

A20

29.7

10.7

7.3

A17

15.6

17

30

15.3

4.3

60.8

61.2

A10.5

A10.5A23.4

A6.4

11

11

12

12

13

16

14

14

30

3 26

2

1

27

28

13

12 17

1811

10 19

209

8 21

227

6 23

245

4 25

29

10 7

9 8

1

2

314

13 4

12 5

611

8 9 101 2 3 4 5 6 7

11121314151617181920

21

1

1 22

4

2

3

10

9

8

7

6

5

15

16

17

18

19

20

21

11

12

13

14

23

590.0

580.0

580.0

585.0585.0

585.0

585.0

595.0

590.0

580.0

M

BLOCK IDENTIFIER

SECTION IDENTIFIER

BLOCK DIMENSIONS (m)

BLOCK AREA (m²)

DRIVEWAY LOCATION

STREET LIGHT

UTILITY MAINTENANCE ACCESS EASEMENT

STORMWATER AND SEWER EASEMENT

FOOTPATH

ESTATE BOUNDARY

INDICATIVE TREE LOCATIONS

Z

LEGEND

1. CONTOUR INTERVAL IS 1m. CONTOURS REPRESENTS PRELIMINARY DESIGNCONTOURS AND MAY BE SUBJECT TO CHANGE, LEVELS SHOULD BE VERIFIEDBY LESSEES

2. PLAN SUBJECT TO SURVEY- FINAL DIMENSIONS, AREAS & BLOCK NUMBERSTO BE OBTAINED FROM DEPOSITED PLANS.

3. REFER TO HOUSING DEVELOPMENT GUIDELINES FOR DETAILS OF;· MAXIMUM RETAINING WALL HEIGHTS.· MAXIMUM LEVEL CHANGES.· SDHDC = SINGLE DWELLING HOUSING DEVELOPMENT CODE

DISCLAIMERTHE SUBURBAN LAND AGENCY MAKES NO WARRANTY REGARDING THEACCURACY OR COMPLETENESS OF INFORMATION ON THIS PUBLICATION ANDRECOMMENDS OBTAINING INDEPENDENT LEGAL ADVICE BEFORECONSIDERING PURCHASING LAND OR MAKING AN OFFER TO PURCHASELAND.

651m²

31

2

1

MID SIZE CODE APPLIED TO THESE BLOCKS (500m2-<550m²) (FORTHE PURPOSE OF R21 OF THE SDHDC)

MANDATORY HABITABLE ROOM ABOVE GARAGE

*

#

FACADES FACING JOHN GORTON DRIVE AND WILLIAM HOVELL DRIVEREQUIRE ACOUSTIC PROTECTION MEASURES TO ADDRESSEXTERNAL ROAD NOISE. REFER TO SDHDC FOR DETAILS.

MANDATORY 2 STOREY BUILT FORM2ST

STAGE BOUNDARY

BLOCKS OVER 500m2 - SIDE SETBACKS ARE MINIMUM 3.0m AND1.5m FOR GARAGE. NO ZERO SETBACK (PROVISION OF R14SDHDC DOES NOT APPLY)

MANDATORY COURTYARD WALL TO MAX HEIGHT OF 1.5m ,CONSTRUCTED OF RENDERED BRICK, BLOCK OR STONEWORK INCOMBINATION WITH FEATURE PANELS, AND SETBACK 600m FROMTHE FRONT BOUNDARY TO INCORPORATE LANDSCAPING, REFER TODRAWING PCP1, DETAIL-1, TYPE 1 & TYPE 2 COURTYARD WALLALONG SECONDARY FRONTAGE TO TERMINATE @ 5m FROMPRIMARY FRONTAGE

INTEGRATED HOUSING DEVELOPMENT

LIMITED DEVELOPMENT POTENTIAL BLOCK(R.49 ESTATE DEVELOPMENT CODE)

567.0

NOTES

MANDATORY ZERO SETBACK (NOMINATED AS SIDE BOUNDARY 2FOR THE PURPOSE OF R15 OF SDHDC)

6.0MINIMUM BUILDING HEIGHT ( IN METRES) ALONGTHE PRIMARY BLOCK FRONTAGES FOR ACOUSTICPROTECTION OF 1 OR 2 STOREY BUILT FRONT

BUS STOP PAD

DESIGN CONTOUR (@ INTERVAL 1m)

DATE

AMENDMENT DETAILS

APPROVEDCHECKDRAWN

N

E

M

A

ISSUE

FIRST

DESIGN

N

E

M

S

T

D

DRAWING No. REVISIONPROJECT No.

PROJECT DRAWING TITLESTATUS SCALE WAE No.

DISCLAIMERALL DIMENSIONS TO BE CHECKED ON SITE BY CONTRACTORPRIOR TO CONSTRUCTION. USE WRITTEN DIMENSIONS ONLY, DONOT SCALE. NOT FOR CONSTRUCTION UNLESS STAMPED BYCERTIFYING AUTHORITY

Authorised for Issue:

SIGN: DATE:

BY:

CLIENT

calibregroup.comC

0 5 10 15 20 25 30 35 40

SCALE 1:1000 (A3)SCALE 1:500 (A1)

N

JW JW 26/02/2020

16-003589 2004

BLOCK DETAILS PLAN

SHEET 5 OF 13

WHITLAM ESTATE STAGE 1

----