API570_Printable Flash Cards

  • Upload
    tipu321

  • View
    227

  • Download
    0

Embed Size (px)

Citation preview

  • 7/30/2019 API570_Printable Flash Cards

    1/45

    Term 1

    The service (s) that has potential

    for none or very few CMLs oncircuit

    Definition 1

    1. Olefin Cold Side,

    2. Anhydrous Ammonia

    Answer found API 570: 5.6.2

    Term 2

    Service (s) that Valves should be

    inspected for thermal fatigue

    Definition 2

    Cat Reformer

    See API 570 section 5.10

    Term 3

    Service(s) with reatively uniform

    Definition 3

    1. Sulfidation,

    2. Sour Water

  • 7/30/2019 API570_Printable Flash Cards

    2/45

    corrosion Answer found API 570: 5.6.3

  • 7/30/2019 API570_Printable Flash Cards

    3/45

    Term 4

    What class abbreviation is used to

    help define theAPI 570 Repair Organization

    Definition 4

    JOC

    J= one who is autherized by the

    Jurisdiction

    O= Owner/Userwho repairs thierown equipment

    C= Contractorthat is acceptble toOwner/User

    Term 5

    What class abbreviation is used to

    help define the

    API 570 Authorized Inspection Agency

    (AI's Employer)

    Definition 5

    JUIC

    J= Inspection Org. of the Jurisdiction

    U = Owner/Userwho maintians

    inspection Org.

    I = Inspection Org. of an Insurance

    Company

    C= Contractorem lo ed b Owner

    Term 6

    The class abbreviation that is used to

    help:

    Determine of corrosion Rate for New

    Definition 6

    SOPI

    S= Same orSimilarService,

    O= Owners Experience,

    P= Published Data, or

  • 7/30/2019 API570_Printable Flash Cards

    4/45

    Service or Change in Service

    is?I= Inspection in 3 months

    Answer found in API 570:7.1.2

  • 7/30/2019 API570_Printable Flash Cards

    5/45

    Term 7

    What is the Class Abbreviation to

    help reminber the

    Primary Resonsiblities of API 570Authorized Inspector

    Definition 7

    TIET= Testing

    I= Inspection

    E= Examination

    Answer found in API 570: 4.3.4

    Term 8

    AIRRis the Class Abbreviation

    for?

    Definition 8

    API 570 Scope which is:A = Alteration,

    I = Inspection,

    R = Repair,

    R = Rerate.

    Answer found in API 570: 1.1.1

    Term 9

    On repairs the minimum radius of an

    Definition 9

    Min of a 1" Radius

    Answer found

  • 7/30/2019 API570_Printable Flash Cards

    6/45

    insert patch is API 570: 8.1.4.2.c/ Fig C.2

  • 7/30/2019 API570_Printable Flash Cards

    7/45

    Term 10

    When performing NDE inspection what

    is the maximum diameter of the CML

    examination point for lines equal to orless than 10 NPS

    Definition 10

    max dia. of 2"

    Answer found API 570 : 3.1.20

    Term 11

    When performing NDE examinations of

    lines greater than 10 NPS what is the

    maximum diameter of the CML

    Definition 11

    Max dia. of 3"

    Answer found API 570 : 3.1.20

    Term 12

    For partially buried pipe What is the

    soil-to-air distance above the soil

    Definition 12

    6" above soil interace shall be

    considered

  • 7/30/2019 API570_Printable Flash Cards

    8/45

    interface that is considered for

    corrosion

    Answer found API 570:3.1.87

  • 7/30/2019 API570_Printable Flash Cards

    9/45

    Term 13

    What is the distance below the soil

    interface to dig when inspecting for

    soil-to-air corrosion

    Definition 13

    dig 6"-12" when inspection for soil-to-

    air corrosion

    Answer found API 570: 7.4.5

    Term 14

    For partially buried pipe What is the

    soil-to-air distance below the soil

    interface that is to be considered for

    corrosion

    Definition 14

    12" below soil interface

    Answer found

    API 570: 3.1.87

    Term 15

    At an Injection point curcuit what is the

    minimum upsteam limit of a more

    Definition 15

    minimum 12" upsteam of the injection

    nozzle shall be examined

  • 7/30/2019 API570_Printable Flash Cards

    10/45

    extensive examination.

    Answer found API 570: 5.5.9

  • 7/30/2019 API570_Printable Flash Cards

    11/45

    Term 16

    For underground piping what is the

    minimum length of buried pipe to

    expose when excavating forinspection

    Definition 16

    6 to 8 feet will need to be excavated for

    inspection

    Answer found API 570: 9.3.6

    Term 17

    Difine:

    ALTERATION

    Definition 17

    Alteration is a Physical change in any

    component that has design

    implications.

    Note:Comparable or duplicate

    replacements and the addition of

    small-bore attachments that do not

    require reinforcement or additional

    support are not considered an

    alteration

    Answer found in API 570: 3.1.2Term 18

    Define:

    Definition 18

    Restore to Suitable

    condictionfor safe operation at

    designed condition

  • 7/30/2019 API570_Printable Flash Cards

    12/45

    Repair Answer found in API 570: 3.1.78

  • 7/30/2019 API570_Printable Flash Cards

    13/45

    Term 19

    Define:

    Defect

    Definition 19

    Defect is difined as

    AnInperfection that exceeds

    acceptance criteria

    Answer found in API 570: 3.1.17

    Term 20

    Define:

    Inperfection

    Definition 20

    Discontinuity that may or may not

    exceed the acceptance criteria

    Answer found in API 570: 3.1.30

    Term 21 Definition 21

    1. Probability of failure

  • 7/30/2019 API570_Printable Flash Cards

    14/45

    RBI's two Primary factors are? 2. Consequence of failure

    Answer found in API 570:5.2

  • 7/30/2019 API570_Printable Flash Cards

    15/45

    Term 22

    What word is used to define the

    number of CML's to obtain

    thickness readings during NDEinspection

    Definition 22

    Represent-ative

    Representative sampling should

    include data for all the various types of

    components and orientations found ineach cicuit.

    Answer found in API 570: 6.5

    Term 23

    CML's that shall be measured

    during a Thickness NDE

    Inspections, are?

    Definition 23

    CMLs with the earliest renewal

    date

    as of the previous inspection

    Answer found in API 570: 6.5

    Term 24

    Intervals for Pressure-relieving

    Definition 24

    Performance

    The API 570 sec 6.7.3.1 states that

    PRD's shall be tested and inspected at

  • 7/30/2019 API570_Printable Flash Cards

    16/45

    devices (PRD's) are

    determined by:

    intervals that are frequent enough to

    verify that the valves perform reliably

    in the particular service conditions.

    Answer found in API 570: 6.7.3.1

  • 7/30/2019 API570_Printable Flash Cards

    17/45

    Term 25

    API 570 Piping

    Classification Inspection scheme

    in section 6.3.4 is based on:

    Definition 25

    Consequence of failure

    See API 570 6.3.1

    Term 26

    Corrosion -Method by which

    process leaks can lead to brittle

    failure is

    Definition 26

    Auto-Refigeration

    API 570 section 6.3.4.2.a

    Term 27

    Crrosion- Type of soil that is most

    Definition 27

    Low Resistivity

  • 7/30/2019 API570_Printable Flash Cards

    18/45

    corrosive is soil with Answer found inAPI 570 section 9.2.4

  • 7/30/2019 API570_Printable Flash Cards

    19/45

    Term 28

    Number of Repairs of new flange

    assemblies to be inspected

    during repairs and alterations isrefered to as

    Definition 28

    Representative

    API 570 section 5.12 States: The

    markings on a representative sample

    of newly installed fasteners and

    gaskets should be examined todetermine whether they meet the

    material specification.

    Answer found API 570: 5.12

    Term 29

    What pipe size is RT preferred for

    thickness readings

    Definition 29

    1 NPS

    570: 5.7.1

    Term 30

    What is the pipe size where UT

    thickness reading may require

    Definition 30

    2 NPS

  • 7/30/2019 API570_Printable Flash Cards

    20/45

    specialized UT equipment 570 5.7.1

  • 7/30/2019 API570_Printable Flash Cards

    21/45

    Term 31

    The term small bore piping refers to

    piping that is

    Definition 31

    2 NPS

    570 3.1.86

    Term 32

    What P-numbers allow the use of pre-

    heat in lieu of PWHT

    Definition 32

    P1 & P3

    570: 8.2.3.2

    Term 33

    For flanges, the thread engagement

    Definition 33

    -1

    570: 5.12

  • 7/30/2019 API570_Printable Flash Cards

    22/45

    acceptance criteria is B31.3:335.2.3

  • 7/30/2019 API570_Printable Flash Cards

    23/45

    Term 34

    What is the minimum # of

    thremocouples required when

    performing a local PWHT instead of a360 degree band

    Definition 34

    2

    570:8.2.3.3.d

    Term 35

    When performing an Internal

    Inspection on piping, What code

    should be followed ?

    Definition 35

    API 510Pressure Vessel

    Inspection Code

    Answer found API 570 5.5.1

    Term 36

    What recommended practice is

    used for

    Definition 36

    API 578

    The Recommedned Pratice for:

    P iti M t i l I d tifi ti M t i l V ifi ti P f

  • 7/30/2019 API570_Printable Flash Cards

    24/45

    Positive Meterial Indentification

    (PMI)

    Material Verification Program for

    New and Existing Piping Systems

    Answer can be found in API 570 sec

    5.9

  • 7/30/2019 API570_Printable Flash Cards

    25/45

    Term 37

    What Standard is used for

    Fitness for Service (FFS)

    Definition 37

    API 579

    Answer is found in API 570: 7.4

    Term 38

    What Recommended Practicecovers

    Risk based Inspections

    Answer found API 570: 5.2

    Definition 38

    API 580

    Answer found in

    API 570: 5.2

    Term 39

    Which standard covers

    Definition 39

    API 598

    Valve Inspection and Testing

  • 7/30/2019 API570_Printable Flash Cards

    26/45

    Valve Inspection and Testing Answer is found API 570: 5.10

    T 40 D fi iti 40

  • 7/30/2019 API570_Printable Flash Cards

    27/45

    Term 40

    What is the Recommended

    Practice for

    Cathodic Protection

    Definition 40

    API 651

    Cathodic Protection of abovegroundPetroleum Storage Tanks

    Answer found in API 570: 9.3.5

    Term 41

    When

    Welding on In-Service Equipment

    containing Flammbles,

    What Publication shall

    be followed?

    Definition 41

    API 2201

    Safe Hot Tapping Practices in the

    Protroleum and Petrochemical

    Industries

    Answer found in

    API 570: 8.2.1

    Term 42

    What is the minimum flash point temp

    Definition 42

    120F

    of hydrocorbons used for leak testing Answer found

  • 7/30/2019 API570_Printable Flash Cards

    28/45

    of hydrocorbons used for leak testing Answer found

    API 570: 5.8.1

    Term 43 Definition 43

  • 7/30/2019 API570_Printable Flash Cards

    29/45

    Term 43

    At what temperature are special

    procedures needed for UT thickness

    readings

    Definition 43

    >150F

    Answer found

    API 570 5.7.1

    Term 44

    When welding, What minimum pre-heat

    temp is substituted for PWHT

    Definition 44

    300F

    API 570: 8.2.3.2

    Term 45

    What is the minimum pre-heat

    temperature, when a local PWHT is

    Definition 45

    300F

    substituted for a full encirclement 570: 8.2.3.3.c

  • 7/30/2019 API570_Printable Flash Cards

    30/45

    PWHT

    Term 46 Definition 46

  • 7/30/2019 API570_Printable Flash Cards

    31/45

    When developing a Inspection

    plan, at what operating temperature

    should a Corrosion Specialist be

    consulted

    >750F

    570:5.1.1.1

    Term 47

    What is the Minimum base metal temp

    during pressure testing when the wall

    thickness is 2" thick

    Definition 47

    (Minimum design metal temperature)

    MDMT + 10F

    570:5.8.3

    Term 48

    What is the Minimum base metal temp

    during pressure testing when the wall

    Definition 48

    (Minimum design metal temperature)

    MDMT + 30F

    thickness is > 2" thick

  • 7/30/2019 API570_Printable Flash Cards

    32/45

    570:5.8.3

    Term 49 Definition 49

  • 7/30/2019 API570_Printable Flash Cards

    33/45

    Whats the minimum duration of a

    hydro test to evluate integrity of buried

    pipe

    8 hr's

    570: 9.3.7

    Term 50

    Whats the Maximum time for obtaining

    thickness reading when corrosion rate

    on new pipe is not known (no other

    data available)

    Definition 50

    3 months

    API 570: 7.1.2.c

    Term 51

    Whats the suggested interval for

    above-grade Visual surveillance of

    Definition 51

    6 months

    buried pipe 570: 9.3.1

  • 7/30/2019 API570_Printable Flash Cards

    34/45

    Term 52 Definition 52

  • 7/30/2019 API570_Printable Flash Cards

    35/45

    What is the length of time a API 570 AI

    must recertify

    3 years

    API 570 A.3.1

    Term 53

    What is the max thickness

    inspection interval for an injection

    point

    Definition 53

    Lesser 3yrs or 1/2 life

    Term 54

    What is the Max External Inspection

    interval for

    Definition 54

    5 Years

    Class 1 & 2 Piping API 570 6.7.3.2

  • 7/30/2019 API570_Printable Flash Cards

    36/45

    Term 55 Definition 55

  • 7/30/2019 API570_Printable Flash Cards

    37/45

    What is the Maximum Interval for Relief

    devices in fouling or corrosive service

    5 years

    API 570: 6.7.3.2

    Term 56

    What is the suggested interval for

    closed-interval Potential Survey of

    buried pipe with poor CP

    Definition 56

    5 Years

    API 570: 9.3.2

    Term 57

    What the suggested interval fo

    evaluation of Soil Corrosivity for

    Definition 57

    5 years

    buried pipe with no CP API 570 9.3.4

  • 7/30/2019 API570_Printable Flash Cards

    38/45

    Term 58 Definition 58

  • 7/30/2019 API570_Printable Flash Cards

    39/45

    What is the max thickness inspection

    interval for Class 1 Piping

    Lesser of

    5 years or 1/2 life

    570 table 2

    Term 59

    What is the maximum interval for Relief

    devices in non- fouling or no-corrosive

    srvice

    Definition 59

    10 years

    570: 6.7.3.2

    Term 60

    Whats is the Maximum External

    Definition 60

    10 years

    Inspection interval for Class 3 Piping 570: Table 2

  • 7/30/2019 API570_Printable Flash Cards

    40/45

    Term 61 Definition 61

  • 7/30/2019 API570_Printable Flash Cards

    41/45

    Whats the maximum Thickness

    Inspection interval for Class 3 piping

    10 years

    570: table 2

    Term 62

    What the maximum interval for RBI Re-

    assessment

    Definition 62

    Per table 2

    570: 5.2.4

    Term 63

    When should temporary welded

    Definition 63

    Next Opportunity

    piping repairs be replaced 570: 8.1.4.1

  • 7/30/2019 API570_Printable Flash Cards

    42/45

    Term 64 Definition 64

  • 7/30/2019 API570_Printable Flash Cards

    43/45

    When shall non-welded repairs &

    temporary leak sealing devices be

    removed and pipe repaired

    Next turnaround

    570: 8.1.5

    Term 65

    What is the maximum size fillet weld

    patch on pipe repairs

    Definition 65

    Size of a the fillet weld patch should

    not exceed 1/2" the pipe diameter

    Answer found

    API 570: Fig C.2

    Term 66

    At an Injection point curcuit what is the

    minimum upsteam limit that is to be

    Definition 66

    12" or 3 pipe dia. whichever is greater

    examined Answer found

    API 570: 5.5.9

  • 7/30/2019 API570_Printable Flash Cards

    44/45

    Term 67 Definition 67

  • 7/30/2019 API570_Printable Flash Cards

    45/45

    At an Injection point curcuit what is the

    minimum downstream limit of a more

    extensive examination

    10 pipe dia. downstream of the

    injection point

    Term 68

    What is the minimum downstream limit

    of an Injection point curcuit

    Definition 68

    Lesser of:1st change in direction + 25'

    or

    2nd change in direction

    API 570: 5.5.9