20
* Available up to 100 GPM systems Aquavar e-ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS • 1 HP thru 5 HP - Pressure Booster Packages • 1AB2 and 2AB2 Prewired Pump/Controller Kits TECHNICAL BROCHURE BAQUAeABII R6

Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

* Available up to 100 GPM systems

Aquavar e-ABIIVARIABLE SPEED CONSTANT PRESSURE SYSTEMS• 1 HP thru 5 HP - Pressure Booster Packages

• 1AB2 and 2AB2 Prewired Pump/Controller Kits

TECHNICAL BROCHUREBAQUAeABII R6

Page 2: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 2

Residential and Commercial Water SystemsCentriPro

Flow

Pressu

re

Typical home water pressure drops when demand is high.

Pressu

re

FlowThe AquaBoost makes up the pressure difference at peak demandfor constant home water pressure.

The AquaBoost Advantage

0

+

0

+

+ +

FEATURES

The e-AB2 variable speed pump controller and complete booster package kits, provide an economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefit. As water use increases, the controller changes pump speed to maintain pressure. Large supply tanks are eliminated and less wear and tear on your pump and motor.

Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration and fire suppression systems. Light commercial applications up to 100 GPM at 55 PSI boost. The e-AB2 is available as either a separate controller or as part of a complete pump package with everything you need to plumb it to a domestic water line.

NEW FEATURES

• Programmed to motor electrical characteristics; just select set pressure.

• Application specific “Start-Up Genie” guides you through quick and easy commissioning

• Removable, graphical control panel with display

• Alarm Log records the last 5 alarms

• Hand on, Auto on, and Off buttons for easy pump operation at the keypad – No toggling between local and remote operation!

• Capable of controlling up to 2 fixed speed pumps, with one standard drive

• Duplex variable speed pumping control with auto lead/lag and alternate

AQUAVAR IPC CONTROLLER PROVIDES CONSTANT PRESSURE CONTROL PLUS MORE FOR THE 3 HP AND 5 HP MOTOR SIZES (REPLACES 3AB2 AND 5AB2 CONTROLLER)

1 HP and 2 HP Controller

3 HP and 5 HP Controller

Page 3: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 3

Residential and Commercial Water SystemsCentriPro

e-AB2 HYDRAULIC SELECTION (e-HM and MCS)

e-AB2 CONFIGURATIONS (e-HM and MCS)

FEET PSI BOOST

GPM

5-10 20 30 40 50 60 70 80 90 100

46 20 1 4 4 9 9 9 9 9 14 14

58 25 1 4 4 9 9 9 9 14 14 14

69 30 1 4 4 10 10 14 14 14 14 14

81 35 1 4 4 10 10 14 14 14 14 14

92 40 2 4 5 11 11 14 14 14 14 14

104 45 2 5 5 11 11 14 14 14 14 14

116 50 2 5 5 11 11 14 14 14 14 15

127 55 2 5 6 11 11 14 14 15 15 15

139 60 3 6 6 12 12 15 15 15 15

150 65 3 6 7 12 12 15 15 15

162 70 3 6 7 12 12 15 15 15

173 75 3 7 8 12 12 13

185 80 3 7 8 12 13 13

Selection Part Number Description

11151AB21HM04 115V 1HP 1" disch, 1" suct V6P N3R wired

1AB21HM04 230V 1HP 1" disch, 1" suct V6P N3R wired

21151AB21HM06 115V 1HP 1" disch, 1" suct V6P N3R wired

1AB21HM06 230V 1HP 1" disch, 1" suct V6P N3R wired

3 2AB23HM06 230V 2HP 1" disch, 1" suct V6P N3R wired

41151AB25HM03 115V 1HP 1" disch, 1.25" suct V15P N3R wired

1AB25HM03 230V 1HP 1" disch, 1.25" suct V15P N3R wired

5 2AB25HM04 230V 2HP 1" disch, 1.25" suct V15P N3R wired

6 2AB25HM05 230V 2HP 1" disch, 1.25" suct V15P N3R wired

7 2AB25HM06 230V 2HP 1" disch, 1.25" suct V15P N3R wired

83AVN35HM07 230V 3HP 1" disch, 1.25" suct IPC-N3R

3AVN15HM07 230V 3HP 1" disch, 1.25" suct IPC-N1

9 2AB22MS1G2D2 230V 2HP 1.25" disch, 1.5" suct V15P N3R wired

10 2AB210HM02 230V 2HP 1.25" disch, 1.5" suct V15P N3R wired

113AVN310HM03 230V 3HP 1.25" disch, 1.5" suct IPC-N3R

3AVN110HM03 230V 3HP 1.25" disch, 1.5" suct IPC-N1

125AVN310HM04 230V 5HP 1.25" disch, 1.5" suct IPC-N3R

5AVN110HM04 230V 5HP 1.25" disch, 1.5" suct IPC-N1

135AVN310HM05 230V 5HP 1.25" disch, 1.5" suct IPC-N3R

5AVN110HM05 230V 5HP 1.25" disch, 1.5" suct IPC-N1

145AVN32MS1J2K2 230V 5HP 1.25" disch, 1.5" suct IPC-N3R

5AVN12MS1J2K2 230V 5HP 1.25" disch, 1.5" suct IPC-N1

155AVN315HM03 230V 5HP 1.5" disch, 2" suct IPC-N3R

5AVN115HM03 230V 5HP 1.5" disch, 2" suct IPC-N1

* 1 HP available in 115 volt input models. Items 8, 11 thru 15 do not include tank. Recommend bladder tank, sized to 20% of pump flow (gpm). Pressure Transducer supplied with all configurations. NOTE: PSI is boosting pressure, NOT total system pressure.

Page 4: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 4

Residential and Commercial Water SystemsCentriPro

ADDENDUM: e-AB2 WITH HSC SELECTION

PSI FEETGPM

10 20 30 40 50

10 23

11

1 2 420 46

30 69

40 922 3

50 1162

60 1392

3 4

70 1623

4

80 1853

90 208 4

95 219 4

Part Number Description

11AB2HSC07B 230V 1HP 1" disch, 1.25" suct V15P wired

1151AB2HSC07B 115V 1HP 1" disch, 1.25" suct V15P wired

2 2AB2HSC15B 230V 2HP 1" disch, 1.25" suct V15P wired

3 2AB2HSC20B 230V 2HP 1" disch, 1.25" suct IPC-N3R

43AVN1HSC30B 230V 3HP 1" disch, 1.25" suct IPC-N1

3AVN3HSC30B 230V 3HP 1" disch, 1.25" suct IPC-N3R

NOTES:• MAWP is 125 PSI; performance per chart accounts for zero lift conditions• Motors are 230V three-phase, ODP design• 1HP and 2HP packages - Tank included, wiring by GWT; supplied with Aquavar AB2 drive• 3HP packages - Tank not included and wiring by others; supplied with Aquavar IPC drive• Pressure transducer supplied with all configurations.

Page 5: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 5

Residential and Commercial Water SystemsCentriPro

ADDENDUM: e-AB2 WITH NPE SELECTION

PSI FEETGPM

60 80 100 120 140

10 23

11

12

315 35

20 46

225 582

330 692

35 81

3340 92

345 104

50 116

55 127

Part Number Description

1 2AB2HSC20B 230V 2HP 1" disch, 1.25" suct V15P wired

23AVN1HSC20B 230V 3HP 1" disch, 1.25" suct IPC-N1

3AVN3HSC20B 230V 3HP 1" disch, 1.25" suct IPC-N3R

35AVN12ST1J9G2 230V 5HP 1.25" disch, 1.5" suct IPC-N1

5AVN32ST1J9G2 230V 5HP 1.25" disch, 1.5" suct IPC-N3R

NOTES:• NPE product is 316L Stainless Steel• MAWP is 125 PSI; performance per chart accounts for zero lift conditions• Motors are 230v three-phase, TEFC design• 2HP packages - Tank included, wiring by GWT; supplied with Aquavar AB2 drive• 3HP and 5HP packages - Tank not included and wiring by others; supplied with Aquavar IPC drive• Pressure transducer supplied with all configurations.

Page 6: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 6

Residential and Commercial Water SystemsCentriPro

1151AB21HM04• 115v SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 4 stg) and Tank (V6P) included• Wall mount set; Transducer; pre-wired

1AB21HM04• 230v SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 4 stg) and Tank (V6P) included• Wall mount set; Transducer; pre-wired

1151AB21HM06• 115V SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 6 stg) and Tank (V6P) included• Wall mount set; Transducer; pre-wired

1AB21HM06• 230v SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 6 stg) and Tank (V6P) included• Wall mount set; Transducer; pre-wired

2AB23HM06• 230v SINGLE PHASE INPUT• 2 HP variable speed controller (2AB2); Nema 3R• Pump (e-HM 6 stg) and Tank (V6P) included• Wall mount set; Transducer; pre-wired

1151AB25HM03• 115V SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 3 stg) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

1AB25HM03• 230v SINGLE PHASE INPUT• 1 HP variable speed controller (1AB2); Nema 3R• Pump (e-HM 3 stg) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

2AB25HM04• 230v SINGLE PHASE INPUT

• 2 HP variable speed controller (2AB2); Nema 3R

• Pump (e-HM 4 stg) and Tank (V15P) included

• Wall mount set; Transducer; pre-wired

2AB25HM05• 230v SINGLE PHASE INPUT• 2 HP variable speed controller (2AB2); Nema 3R• Pump (e-HM 5 stg) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

2AB25HM06• 230v SINGLE PHASE INPUT• 2 HP variable speed controller (2AB2); Nema 3R• Pump (e-HM 6 stg) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

3AVN35HM07• 230v SINGLE PHASE INPUT• 3 HP variable speed controller (Aquavar IPC); Nema

3R• Pump (e-HM 7 stg) and Transducer (included)• Tank (not included) and wiring (by others)

3AVN15HM07• 230v SINGLE PHASE INPUT• 3 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (e-HM 7 stg) and Transducer (included)• Tank (not included) and wiring (by others)

2AB22MS1G2D2• 230v SINGLE PHASE INPUT• 2 HP variable speed controller (2AB2); Nema 3R• Pump (MCS) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

2AB210HM02• 230v SINGLE PHASE INPUT• 2 HP variable speed controller (2AB2); Nema 3R• Pump (e-HM 2 stg) and Tank (V15P) included• Wall mount set; Transducer; pre-wired

3AVN310HM03• 230v SINGLE PHASE INPUT• 3 HP variable speed controller (Aquavar IPC);

Nema 3R• Pump (e-HM 3 stg) and Transducer (included)• Tank (not included) and wiring (by others)

INPUT AND OUTPUT POWER (VOLTAGE AND PHASE)• All 1AB2 and 2AB2 require single-phase input power • All controllers output three-phase, 230 Volt power

o All will work on 1Ø, 208-230V input power • All pumps are equipped with three-phase motorso 1151AB2’s will work on 1Ø, 115V input power

Page 7: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 7

Residential and Commercial Water SystemsCentriPro

INPUT AND OUTPUT POWER (VOLTAGE AND PHASE) continued

3AVN110HM03• 230v SINGLE PHASE INPUT• 3 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (e-HM 3 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN310HM04• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC); Nema

3R• Pump (e-HM 4 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN110HM04• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (e-HM 4 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN310HM05• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 3R• Pump (e-HM 5 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN110HM05• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (e-HM 5 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN32MS1J2K2• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 3R• Pump (MCS) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN12MS1J2K2• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (MCS) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN315HM03• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 3R• Pump (e-HM 3 stg) and Transducer (included)• Tank (not included) and wiring (by others)

5AVN115HM03• 230v SINGLE PHASE INPUT• 5 HP variable speed controller (Aquavar IPC);

Nema 1• Pump (e-HM 3 stg) and Transducer (included)• Tank (not included) and wiring (by others)

CONTROLLERS ONLY

1AB2• 4.2 Amp, 230v 1HP Nema 3R, transducer & cable• Single phase Input; Three phase Output

1151AB2• 4.2 Amp, 115v 1HP Nema 3R, transducer & cable• Single phase Input; Three phase Output

2AB2• 6.9 Amp, 230v 2HP Nema 3R, transducer & cable• Single phase Input; Three phase Output

AVB10030C0X0X0X1• 10.6 Amp, 230v 3HP Nema 3R, transducer & cable• Single phase Input; Three phase Output

AVB10030A0X0X0X1• 10.6 Amp, 230v 3HP Nema 1, transducer & cable• Single phase Input; Three phase Output

AVB10050C0X0X0X1• 16.7 Amp, 230v 3HP Nema 3R, transducer & cable• Single phase Input; Three phase Output

AVB10050A0X0X0X1• 16.7 Amp, 230v 3HP Nema 1, transducer & cable• Single phase Input; Three phase Output

Page 8: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 8

Residential and Commercial Water SystemsCentriPro

11.0 Ref. = V15P 15.1 Ref. = V15P

32.0 Ref.

2.9

4.32 — HSC07BHSC15B

5.75 — HSC20B

3.7 Ref. Check Valve Not Included

Suction1.25" NPTSuction

1.25" NPT

Discharge .1" NPT26.5 Ref.

4.3

8.53

7.00.79

17.75 Ref. — HSC07B19.62 Ref. — HSC15B21.06 Ref. — HSC20B

5.19 Ref. — HSC07B5.19 Ref. — HSC15B6.63 Ref. — HSC20B

Ø 5.63 Ref.

3.50

4.03 Ref.

4.50

8.00 Ref.

8.06

3 x ¼" NPT Plug

1AB2HSC07B• 230V SINGLE PHASE INPUT

• 1 HP variable speed controller (1AB2); Nema 3R

• Pump (HSC07B) with Tank (V15P) included

• Wall mount set; Transducer; pre-wired

1151AB2HSC07B• 115V SINGLE PHASE INPUT

• 1 HP variable speed controller (1AB2); Nema 3R

• Pump (HSC07B) with Tank (V15P) included

• Wall mount set; Transducer; pre-wired

2AB2HSC15B• 230V SINGLE PHASE INPUT

• 2 HP variable speed controller (2AB2); Nema 3R

• Pump (HSC15B) with Tank (V15P) included

• Wall mount set; Transducer; pre-wired

3AVN1HSC20B• 230V SINGLE PHASE INPUT

• 3 HP variable speed controller (Aquavar IPC); Nema 1

• Pump (HSC20B) and Transducer included

• Tank (not included) and wiring (by other)

3AVN3HSC20B• 230V SINGLE PHASE INPUT

• 3 HP variable speed controller (Aquavar IPC); Nema 3R

• Pump (HSC20B) and Transducer included

• Tank (not included) and wiring (by other)

INPUT AND OUTPUT POWER (VOLTAGE AND PHASE) WITH HSC• All 1AB2 and 2AB2 require single-phase input power • All controllers output three-phase, 230 Volt power

o All will work on 1Ø, 208-230V input power • All pumps are equipped with three-phase motorso 1151AB2 will work on 1Ø, 115V input power

Page 9: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 9

Residential and Commercial Water SystemsCentriPro

SUGGESTED AB2 INSTALLATION FOR MUNICIPAL WATER SYSTEM

Home Supply Water Main

Check Valve*

Isolation Valves

Unions

Check Valve*

To Drain

ReliefValve

GaugeTank

AquaBoost Controller

CircuitBreaker

DisconnectTransducer

Motor/PumpFigure 1

SUGGESTED AQUABOOST INSTALLATION FOR WELL PUMP SYSTEM

Home Supply Well Supply

Check Valve*

Isolation Valves

Unions

Check Valve*

To Drain

ReliefValve

GaugeTank

AquaBoostController

Controller

CircuitBreaker

Disconnect

AtmosphericStorage Tank

Transducer

Motor/Pump

Isolation Valve

Figure 2

*Spring check valve - provided by installer

*Spring check valve - provided by installer

Page 10: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 10

Residential and Commercial Water SystemsCentriPro

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

100

140

80

0

40

60

160

120

180

5 10 15

20

0

1HM04, 1HM06Performance at 0 suctionVariable Speed Curves

1AB21HM041151AB21HM04

30 Hz

1AB21HM061151AB21HM06

60 Hz

60 Hz

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

100

200

0

50

150

250

5 10 15 20 250

2AB23HM06

60 Hz

30 Hz

3HM06Performance at 0 suctionVariable Speed Curves

Page 11: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 11

Residential and Commercial Water SystemsCentriPro

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

100

200

0

50

150

250

25 50 75 100 125 1500

5AVN315HM035AVN115HM03

60 Hz

30 Hz

15HM03Performance at 0 suctionVariable Speed Curves

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

100

75

0

50

125

150

25 50 100 125 15075

25

0

5AVN32MS1J2K25AVN12MS1J2K2

2MS1G2D2, 2MS1J2K2Performance at 0 suctionVariable Speed Curves

2AB22MS1G2D2

60 Hz

60 Hz

30 Hz

Page 12: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 12

Residential and Commercial Water SystemsCentriPro

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

100

200

0

50

150

5 10 20 25 3015 40 5045350

2AB25HM05

2AB25HM04

60 Hz

60 Hz

60 Hz

30 Hz

5HM03, 5HM04, 5HM05Performance at 0 suctionVariable Speed Curves

1AB25HM031151AB25HM03

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

200

100

0

250

300

150

5 10 20 25 3015 40 504535

50

0

2AB25HM06

60 Hz

30 Hz

5HM06, 5HM07Performance at 0 suctionVariable Speed Curves

3AVN35HM073AVN15HM07

Page 13: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 13

Residential and Commercial Water SystemsCentriPro

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

150

100

0

175

200

125

10 20 7030 40 50 8060

50

75

25

0

2AB210HM02

60 Hz

60 Hz

30 Hz

10HM02, 10HM03Performance at 0 suctionVariable Speed Curves

3AVN310HM033AVN110HM03

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

)

150

100

0

250

300

200

10 20 7030 40 50 8060

50

0

5AVN310HM045AVN110HM04

60 Hz

60 Hz

30 Hz

10HM04, 10HM05Performance at 0 suctionVariable Speed Curves5AVN310HM05

5AVN110HM05

Page 14: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 14

Residential and Commercial Water SystemsCentriPro

FEET

CAPACITY (Q)

U.S. GPM

TOTA

L D

YN

AM

IC H

EA

D (H

) 100

140

0

20

40

60

80

120

4020 80 10060 140 1601200

2ST1J9G2

2ST1H9B2

60 Hz

60 Hz

60 Hz

30 Hz

2ST1F9D2, 2ST1H9B2, 2ST1J9G2Performance at 0 suctionVariable Speed Curves

2ST1F9D2

Page 15: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 15

Residential and Commercial Water SystemsCentriPro

(135.36)5.33

(259.08)10.20

(237.06)9.33

(12.07).48

(157.90)6.22

(99.06)3.90

(114.30)4.50

(57.15)2.25

(8.38).33

(242.04)9.53 (232.56)

9.16

(81.28)3.20

(16.51).65

(135.36)5.33

(259.08)10.20

(237.06)9.33

(12.07).48

(157.90)6.22

(99.06)3.90

(114.30)4.50

(57.15)2.25

(8.38).33

(242.04)9.53 (232.56)

9.16

(81.28)3.20

(16.51).65

(135.36)5.33

(259.08)10.20

(237.06)9.33

(12.07).48

(157.90)6.22

(99.06)3.90

(114.30)4.50

(57.15)2.25

(8.38).33

(242.04)9.53 (232.56)

9.16

(81.28)3.20

(16.51).65

AQUAVAR ABII CONTROLLER FEATURES

Input Power* — 208-230V ±15%, single phase (controller only)

Output Power — Up to 230V three phase (based on input voltage). Motor rated for 208-230V, ±10%.

Maximum Output Current — 4.2 amps – 1AB2 (1 HP) — 6.9 amps – 2AB2 (2 HP)

Input Controls — Up and down buttons to set pressure.

Signal Lights — Power on, pump running, inverter stopped, pump stopped, standby, faults/errors.

Electrical Efficiency — Over 95% at full load

Protection Against — Short circuit, under voltage, over-load, motor temperature, dead heading, run out, suc-tion loss, sensor fault, bound pump, over voltage, static discharge. Note: Suction loss/run out is set for minimum 10 psi at discharge!

Ambient Temperature — 34º F to 104º F

Maximum Humidity — 95% at 104º F, non-condensing

Air Pollution — Avoid mounting in areas with excessive dust, acids, corrosives and salts.

Approvals — (Listing on Controller Only)

Controller Enclosure — Outdoor, NEMA 3R, IP 43 (Rain-tight)

Mounting — Wall mount with mounting hardware.

Cooling — Convection with cast aluminum heat sink. — 3 HP, 5 HP with temperature fan

Transducer — 0.5 - 4.5 VDC with 5 VDC power supply, 100 psi range, 10-foot 3-wire shielded cable.

Input Wire — 5 feet of 14, 10 or 8 gauge cable. Depend-ing on size, cable is pre-wired to controller and motor conduit box.

Output Wire — 10 feet of 14 gauge cable. Cable is pre-wired to controller and pump motor (when provided).

*Low input voltage may affect motor operation.

PRESSURE RANGENominal Range — Field adjustable from 20 - 85 psi, total system pressure.

DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. PLUMB RELIEF VALVE OUTSIDE OR TO A DRAIN.

WARNING

1AB22AB2

(135.36)5.33

(259.08)10.20

(237.06)9.33

(12.07).48

(157.90)6.22

(99.06)3.90

(114.30)4.50

(57.15)2.25

(8.38).33

(242.04)9.53 (232.56)

9.16

(81.28)3.20

(16.51).65

C US

Tested to UL 778 andCSA 22.2 108 StandardsBy Canadian StandardsAssociationFile #LR38549

UL®

½"LiquidTight

Page 16: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 16

Residential and Commercial Water SystemsCentriPro

AQUAVAR IPC FEATURES

Input Power* — 200V to 240V ±10%, single phase (controller only)

Output Power — Up to 230V three phase (based on input voltage).

Maximum Output Current — 10.6 amps (3 HP) — 16.7 amps (5 HP)

Input Controls — Keypad; LCD graphical display

Signal Lights — Power on, inverter stopped, standby, warning/alarms; auto ON.

Electrical Efficiency — Over 95% at full load

Protection Against — MOTOR: Ground Fault, Motor Stall, Motor Over Temperature, Motor Condensation, Motor Overload. PUMP: Pump No-Flow, Under Pressure, No Water / Loss of Prime, Short-Cycle.

Ambient Temperature — 34º F to 114º F

Maximum Humidity — 93% at 114º F, non-condensing

Air Pollution — Avoid mounting in areas with excessive dust, acids, corrosives and salts.

Approvals — (Listing on Controller Only)

Controller Enclosure — Outdoor, NEMA 3R, IP 43 (Rain-tight); Indoor, NEMA 1, IP 21

Mounting — Wall mount

Cooling — Convection with cast aluminum heat sink. — With temperature fan

Transducer — 4-20 mA power supply, 300 psi range, 16-foot shielded cable.

Input Wire — Supplied by installer, refer to instruction manual

Output Wire — Supplied by installer, refer to instruction manual

*Low input voltage may affect motor operation.

PRESSURE RANGENominal Range — Field adjustable through 300 psi, total system pressure.

DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. PLUMB RELIEF VALVE OUTSIDE OR TO A DRAIN.

WARNING

3 HP5 HP

C US

Tested to UL 778 andCSA 22.2 108 StandardsBy Canadian StandardsAssociationFile #LR38549

UL®

Top and bottom mounting holes

HEIGHT

Enclosure: 18.90 in (480 mm)

Distance Between Mounting Holes (a): 17.87 in (454 mm)

WIDTH

Enclosure: 9.53 in (242 mm)

Distance Between Mounting Holes (b): 8.27 in (210 mm)

DEPTH

Without A/B Option Card*: 10.24 in (260 mm)

SCREW HOLES

c: 0.47 in (12 mm)

d: 0.75 in (19 mm)

e: 0.35 in (9 mm)

f: 0.35 in (9 mm)

Maximum Weight: 51 lbs (23.1 kg)

* Depth of enclosure will vary with different options installed.

Page 17: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 17

Residential and Commercial Water SystemsCentriPro

DIMENSIONS (For Reference Only - Do not use for construction purposes)

MCS PUMP WITH TANK AND TEE

Capacities — to 120 GPM Pump Connections — 1¼ x 1½ NPT

Rotation — Right hand clockwise, Maximum Temperature of Water — 120º F viewed from motor end NOTE: Tank Liquid Temperature Limit is 120º F Pump Liquid Temperature Limit is 140º F

Materials — 316L stainless steel casing Maximum System Working Pressure — 125 psi 316L impeller

Motor — 1 HP, ODP, Three Phase, Seal — Carbon / Silicon Carbide / EPR 208-230/460V

Overload protection, starters, heaters not required.Dimensions are in inches.

11.0 Ref. = V15P 15.1 Ref. = V15P

32.0 Ref.

2.9

2.1

3.7 Ref. Check Valve Not Included

Suction1.5" NPT

Discharge1.25" NPT

26.5 Ref.

4.3

5.5 5.7 5.4

6.8 Ref. 11.8 Ref.

L Ref.8.5 Ref.

Page 18: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 18

Residential and Commercial Water SystemsCentriPro

DIMENSIONS (For Reference Only - Do not use for construction purposes)

e-HM PUMPS

Capacities — to 12 GPM (1HM)

to 23 GPM (3HM)

to 45 GPM (5HM)

Rotation — Right hand clockwise, viewed from motor end

Materials — 316L stainless steel for all liquid handling components

Motor — 1 HP, TEFC, Three Phase,208-230/460V

— 1.5 HP, TEFC, Three Phase,208-230/460V

— 2 HP, TEFC, Three Phase,208-230/460V

D Ref.13.6 Ref. = V6P

15.1 Ref. = V15P

H Ref.

L3

3.7 Ref.

Suction NPT

Discharge NPT

17.0 Ref.

3.5

4.9L5

L4

6.0 Ref.

L Ref.

L2 Ref.L1

Overload protection, starters, heaters not required. Dimensions are in inches.

Pipe Connections — 1 x 1 NPT (1HM/3HM)

— 1 x 1¼ NPT (5HM)

Maximum Temperature of Water — 120º F

NOTE: Tank Liquid Temperature Limit is 120º F Pump Liquid Temperature Limit is 212º F

Maximum System Working Pressure — 145 psi

Seal — Carbon / Silicon Carbide / EPR

Check Valve Not Included

Page 19: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

PAGE 19

Residential and Commercial Water SystemsCentriPro

DIMENSIONS (For Reference Only - Do not use for construction purposes)

e-HM PUMPS

Capacities — to 45 GPM (5HM) to 75 GPM (10HM) to 127 GPM (15HM)

Rotation — Right hand clockwise, viewed from motor end

Materials — 316L stainless steel for all liquid handling components

Motor — 2 HP, TEFC, Three Phase,208-230/460V (5HM/10HM) — 3 HP, TEFC, Three Phase,208-230/460V (10HM) — 4 HP, TEFC, Three Phase,208-230/460V (10HM) — 5.5 HP, TEFC, Three Phase,208-230/460V (10HM/15HM)

11.0 Ref. 15.1 Ref. = V15P

H Ref.

L5

L1

Suction NPT

Discharge NPT

H1 Ref.

3.6

W1 L2 L4L3

W Ref. L Ref.

Overload protection, starters, heaters not required. Dimensions are in inches.

Pipe Connections — 1 x 1¼ NPT (5HM)

— 1¼ x 1½ NPT (10HM)

— 1½ x 2 NPT (15HM)

Maximum Temperature of Water — 120º F

NOTE: Tank Liquid Temperature Limit is 120º F Pump Liquid Temperature Limit is 212º F

Maximum System Working Pressure — 85 psi

Seal — Carbon / Silicon Carbide / EPR

3.7 Ref. Check Valve Not Included

Page 20: Aquavar e-ABII...Think of it as “Cruise Control” for your pump! The e-AB2 is available with a range of flow rates to handle homes with up to four baths, irrigation, filtration

CentriPro and AquaBoost are trademarks of Xylem Inc. or one of its subsidiaries. © 2020 Xylem Inc. BAQUAeABII R6 February 2020

Xylem Inc.2881 East Bayard Street Ext., Suite ASeneca Falls, NY 13148Phone: (866) 325-4210 • Fax: (888) 322-5877www.xylem.com/centripro

ALTERNATE PUMP MODELS FOR USE WITH 2AB2 CONTROLLER3642 — 1½, 2 HP, 3 ph, ODP or TEFC motor versionsGT — 1½, 2 HP, 3 ph, ODP or TEFC motor versionsHSC — 1½, 2 HP, 3 ph, ODP or TEFC motor versions10GB — 1½, 2 HP, 3 ph, ODP or TEFC motor versionsNPE — 1½, 2 HP, 3 ph, ODP or TEFC motor versionsNPO — 1½, 2 HP, 3 ph, ODP or TEFC motor versionsICS — 1½, 2 HP, 3 ph, ODP or TEFC motor versions

ALTERNATE PUMP MODELS FOR USE WITH 1AB2 CONTROLLERMCC — ½, ¾, 1 HP, 3 ph, ODP or TEFC motor versions3642 — 1⁄3, ½, 1 HP, 3 ph, ODP or TEFC motor versionsGT073, GT103 — 3 ph, ODP or TEFC motor versionsHSC07, HSC10 — 3 ph, ODP or TEFC motor versions5GB, 7GB — ½, ¾, 1 HP, 3 ph, ODP or TEFC motor versionsNPE — ½, ¾, 1 HP, 3 ph, ODP or TEFC motor versionsNPO — ½, ¾, 1 HP, 3 ph, ODP or TEFC motor versionsICS — ½, ¾, 1 HP, 3 ph, ODP or TEFC motor versionsLB — ½ and ¾ HP, 3 ph, ODP or TEFC motor versions

Note: These pumps are not currently offered as a packaged kit. All units require three phase motors. Size pumps and controllers according to service factor amps of the motor.

SUBMERSIBLE PUMPS: Use Aquavar SOLO or S-Drive controllers for submersible applications, they have filters built-in and are programmed for submersibles; alternatively Aquavar IPC with use with DV/DT filter can be used for submersible applications.

PACKAGED HARDWARE WITHOUT PUMP AND MOTOR (SEE PRICING PAGE)

Part Number 15K40KIT INCLUDES:

1) Tank – V6P (2 gallons) 3) Pipe Plug – 1⁄2", 6K682) 1" Bronze Discharge Tee – AV20-6 4) Pressure Gauge

Part Number 15K108KIT INCLUDES:

1) Tank – V15P 3) Pipe Plug – 1⁄2", 6K682) 1¼" Bronze Discharge Tee – AV20-12 4) Pressure Gauge

Tank and Tee assembly incl. L L1 L2 L3 L4 L5 D H

Suction NPT

Discharge NPT Page

2MS1G2D2BP Yes 15.9 13

2MS1J2K2BP No 18.3 13

1HM04N05T6PBQEBP Yes 17.8 4.2 10.4 2.8 2.2 1.0 8.25" 21.1 1" 1" 14

1HM06N05T6PBQEBP Yes 20.9 5.8 11.9 2.8 2.2 1.0 8.25" 21.1 1" 1" 14

3HM06N11T6PBQEBP Yes 20.9 5.8 11.9 2.8 2.2 1.0 8.25" 21.1 1" 1" 14

5HM03N07T6PBQEBP Yes 19.2 4.1 11.9 2.8 3.9 3.7 11" 22.5 1.25" 1" 14

5HM04N11T6PBQEBP Yes 20.2 5.1 11.9 2.8 3.9 3.7 11" 22.5 1.25" 1" 14

5HM05N15T6PBQEBP Yes 21.2 6.1 11.9 2.8 3.9 3.7 11" 22.5 1.25" 1" 14

L L1 L2 L3 L4 L5 H H1 W W1Suction

NPTDischarge

NPT Page

5HM06N15T6PBQEBP Yes 22.0 6.2 4.2 11.9 3.9 2.8 23.4 17.9 6.5 5.5 1.25" 1" 15

5HM07N22T6PBQEBP No 25.1 7.2 4.2 14.7 4.9 2.8 23.4 17.9 6.5 5.5 1.25" 1" 15

10HM02N15T6PBQEBP Yes 17.5 4.9 4.3 4.8 3.9 2.9 30.7 25.2 7.7 6.6 1.5" 1.25" 15

10HM03N22T6PBQEBP No 19.5 4.9 4.3 5.7 4.9 2.9 30.7 25.2 7.7 6.6 1.5" 1.25" 15

10HM04N30T6PBQEBP No 20.8 6.2 4.3 6.9 4.9 2.9 30.7 25.2 7.7 6.6 1.5" 1.25" 15

10HM05N40T6PBQEBP No 23.3 7.5 4.3 9.0 5.5 2.9 30.7 25.2 7.7 6.6 1.5" 1.25" 15

15HM03N40T6PBQEBP No 22.2 5.8 4.3 6.9 5.5 2.9 30.7 25.2 7.7 6.6 2" 1.5" 15

ELEVATION DIMENSIONS - REFERENCES PAGES 14 - 16