3
Baumer Page 1 / 3 www.baumer.com Special Features Application GOST - R GOST Specifications AR SS Case Test Gauge (ACC + 0.25%) Bourdon type Standard Version : 150 mm, 200 mm & 250 mm : : : : 31- 08 -12 Design and specifications subject to change without notice < < < < < < Stainless steel case & high precision measuring system High resolution dial Anti parallax mirror band (eye friendly) Socket directly welded to case Standard followed in general EN 837-1 Calibration certificate with traceability to National / International standards. < Calibration / testing in laboratory < Fits for various process Industries and all gaseous / liquid media that will not obstruct the pressure system Accuracy Ambient temperature Process temperature Operating pressure range ±0.25% of F. S. Maximum 65°C Maximum 65°C 75% of the Scale Value (At +20 °C) : : : : : Case Bourdon Socket Movement Integral Dampening Screw & Bezel AISI 304 SS (Bayonet Type) Beryllium Copper AISI 316L SS High Precision Jewel Bearing Type AISI 316 SS Protection Dial Pointer Pointer Stopper Gasket Welding Window Blow Off Disc Carrying Case Calibration certificate IP 65 Aluminum, Green with Black Marking & Anti Parallax Mirror Band Balanced, Knife Edge Micrometer Adjustable Spring Type Neoprene Alloy Brazing Shatter proof / Safety Glass Neoprene Wooden carrying case Calibration certificate traceable to National / International standard. Temperature effect : The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified accuracy while measurement :- Formula : ± 0.04 x (t2 - t1) % of F. S. where t1 = reference temperature (+20°C) and t2 = ambient temperature in °C. : : : : : : : : : :

AR - ITOPPLUSdemoweb644.itopplus.com/Files/Name2/CONTENT1058108600598.… · GOST - R GOST Specifications AR SS Case Test Gauge (ACC + 0.25%) Bourdon type Standard Version : 150 mm,

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AR - ITOPPLUSdemoweb644.itopplus.com/Files/Name2/CONTENT1058108600598.… · GOST - R GOST Specifications AR SS Case Test Gauge (ACC + 0.25%) Bourdon type Standard Version : 150 mm,

Baumer

Page 1 / 3www.baumer.com

Special Features

Application

GOST - R

GOST

Specifications

ARSS Case Test Gauge (ACC + 0.25%)Bourdon type

Standard Version : 150 mm, 200 mm & 250 mm

:

:

:

:

31-

08 -

12 D

esi

gn a

nd s

peci

ficatio

ns

subje

ct to c

hange w

ithout notic

e

<

<

<

<

<

<

Stainless steel case & high precision measuring system

High resolution dial

Anti parallax mirror band (eye friendly)

Socket directly welded to case

Standard followed in general EN 837-1

Calibration certificate with traceability to National /

International standards.

< Calibration / testing in laboratory

< Fits for various process Industries and all gaseous / liquid media that

will not obstruct the pressure system

Accuracy

Ambient temperature

Process temperature

Operating pressure range

±0.25% of F. S.

Maximum 65°C

Maximum 65°C

75% of the Scale Value

(At +20 °C)

:

:

:

:

:

Case

Bourdon

Socket

Movement

Integral Dampening Screw

& Bezel AISI 304 SS (Bayonet Type)

Beryllium Copper

AISI 316L SS

High Precision Jewel Bearing Type

AISI 316 SS

Protection

Dial

Pointer

Pointer Stopper

Gasket

Welding

Window

Blow Off Disc

Carrying Case

Calibration certificate

IP 65

Aluminum, Green with Black Marking & Anti Parallax Mirror Band

Balanced, Knife Edge Micrometer Adjustable

Spring Type

Neoprene

Alloy Brazing

Shatter proof / Safety Glass

Neoprene

Wooden carrying case

Calibration certificate traceable to National / International standard.

Temperature effect :

The variation of indication caused by effects of temperature is to be calculated by below formula; which is to be added in the specified

accuracy while measurement :- Formula :

± 0.04 x (t2 - t1) % of F. S. where t1 = reference temperature (+20°C)

and t2 = ambient temperature in °C.

:

:

:

:

:

:

:

:

:

:

Page 2: AR - ITOPPLUSdemoweb644.itopplus.com/Files/Name2/CONTENT1058108600598.… · GOST - R GOST Specifications AR SS Case Test Gauge (ACC + 0.25%) Bourdon type Standard Version : 150 mm,

Page 2 / 3www.baumer.com

31-

08 -

12 D

esi

gn a

nd s

peci

ficatio

ns

subje

ct to c

hange w

ithout notic

e

Dimensions - standard version

Baumer ARSS Case Test Gauge (ACC + 0.25%)Bourdon type

TYPE 1

ØD ØC

B

A

120°

ØN

ØU

HS

E

ØI

M

TYPE 2

A

B

ØCØD

E

NS

150 15 46.5 149 161 6 1160.0

Weight in gram

(With Box)

1.5230245 7

6186 168

18 49 201.5 216.5

E

22200

ØUØN ØI SØDØCBA

2050.0

22

14.5

14.5

HM

229

174

1.5276290 718 52 250 263 22250 2450.014.5286.5

NS

150 15 49 149 161

18 49 201.5 216.5

E

22200

ØDØCBA

22

18 52 250 263 22250

1100.0

Weight in gram

(With Box)

1975.0

2375.0

TYPE 5

AB

ØCØD

120°

ØN

ØU

E

ØI

S

TYPE 3

ØD ØC

B

A

E

NS

150 15 49 149 161

18 49 201.5 216.5

E

22200

ØDØCBA

22

18 52 250 263 22250

1075.0

Weight in gram

(With Box)

1950.0

2350.0

NS

150 15 49 149 161 5 1160.0

Weight in gram

(With Box)

1.5230245 7

6186 168

18 49 201.5 216.5

E

22200

ØUØN ØI SØDØCBA

2030.0

22

1.5276290 718 52 250 263 22250 2480.0

TYPE 9

V

J

K

ØDØC

AB

E

NS

150 15 49 149 161 1120.0

Weight in gram

(With Box)

16165 208

166106.5 16

18 49 201.5 216.5

E

22200

KJ VØDØCBA

1950.0

22

30180 27018 52 250 263 22250 2300.0

Notes : • Drawings are not to scale. • All Dimensions are in mm. • NS = Nominal Size.

Page 3: AR - ITOPPLUSdemoweb644.itopplus.com/Files/Name2/CONTENT1058108600598.… · GOST - R GOST Specifications AR SS Case Test Gauge (ACC + 0.25%) Bourdon type Standard Version : 150 mm,

Page 3 / 3www.baumer.com

Baumer

Range Table

Pressure range

Single scale (kg/cm² or bar)

psi kg/cm² psi kg/cm² psi kg/cm²

Dual scale (psi with kg/cm²)

Vacuum range

Single scale

- 1/0

Overload protector (gauge saver)**

Needle valve

ED

*

Type of Mounting

Code

Nominal Size

Basic Model

1

2

Gauge Connection

Wall / surface / projection

Mounting with bottom entry

Direct bottom entry

3

5

9

Direct lower back entry

Lower back entry with front flange

Lower back entry with mounting bracket

1/4 “ NPT (M) 2NM 4NM4BM ½" BSP (M) Standard

ARSS Case Test Gauge (ACC + 0.25%)Bourdon type

2Note : We offer National / International Scales like kPa, MPa, bar, psi, kg/cm & Dual Scale like kPa with psi, kPa with bar, bar with psi or 2 Equivalent scales as per the requirement can be provided on request. Following are the example tables for kg/cm or bar

0/0.6

0/1

0/1.6

0/2.5

0/4

0/6

0/10

0/16

0/25

0/40

0/60

0/100

0/160

0/250

0/400

0/600

0/1000

0/15

0/30

0/60

0/100

0/150

0/220

0/300

0/1

0/2

0/4

0/7

0/10

0/16

0/20

0/400

0/500

0/600

0/1000

0/1500

0/2200

0/3000

28

0/35

0/40

0/70

0/100

0/160

0/200

0/ 0/4000

0/5000

0/6000

0/10000

0/15000

0/

0/350

0/420

0/700

0/1000

280

(kg/cm² or bar) (mmHg)

- 760/0

Accessories (Refer Datasheet for complete specifications)

* Refer catalogue for Valves & Manifolds. ** For Pressure Ranges.Note : Other Scale are available on customer request.

Please refer to factory. Compound ranges are not preferred.

31-

08 -

12 D

esi

gn a

nd s

peci

ficatio

ns

subje

ct to c

hange w

ithout notic

e

Refer range table

Range

Optional Extras

J

250 mm

I

200 mm

H

150 mm

½ ”NPT (M) Standard

RH

SW

SX

Custom designed dial

Dial tag marking

SS tag plate

Helium leak test

Plexi glass

TB

RW

2Ordering Example: AR . X . X . XXX . 0/10 kg/cm . XX

For other optional items, please contact factory for delivery and minimum quantity of order.

Note : Specifications and dimensions given in this product catalogue represents the state of engineering at the time of printing.

Modifications may take place and materials specified may be replaced by others without prior notice.

Note : Female Gauge Connections are available on request.

X

AR

X

XXX

XX

0/102kg/cm

How To Order Example