12
ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE ISOLATION UNITS ALTERNATE CARE FACILITY (ACF)

ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE ISOLATION UNITSALTERNATE CARE FACILITY (ACF)

Page 2: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

E9E8 E7

NO

TO

ILET

E1

E2

E5

E6

E3

E10E4

ENGINEERING CHANGES

• Field modified isolation room entry door

• Add louver with gravity damper and balancing damper

• Add exhaust fan with HEPA filtering

• Add mounted lighting• Add emergency back-up power• Add electrical and data outlets• Add washable wall and floor

covering

MEDICAL EQUIPMENT

E1. Ventilator capable: Storage CabinetE2. Telemetry/Pump on IV Stand E3. StoolE4. Over bed tableE5. Mobile work stationE6. Linen hamperE7. Sharps/GlovesE8. Hand sanitizer stationE9. Infectious wasteE10. Patient bed

A2HC – COVID ACUTE CONTAINER(PROOF OF PRINCIPLE)

CONCEPT

8 ft

16 ft

VIEW

WAL

L

Page 3: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

MSC TotalLRD 4283MVD 326NAD 4681NWD 3314POD 29SAD 7487SPD 2687SWD 2592

PODS Inventory by MSC

4283

4681

7487

326

2592

3314

2687

ESTIMATED CONTAINER AVAILABILITY

* Verified from 1 source –PODS LLC; working others

Note 1: This concept will work with multiple versions of portable moving containers.

Page 4: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

E1

E2

E5

E6

E9

E3

E10E4

E8 E7

VIEW

WAL

L

ENGINEERING CHANGES

• Field modified isolation room entry door • Add louver with gravity damper and balancing damper• Add exhaust fan with HEPA filtering• Add mounted lighting• Add emergency back-up power• Add electrical and data outlets• Provide washable wall and floor covering

NEW EQUIPMENT

E1. Ventilator capable: Storage CabinetE2. Telemetry/Pump on IV Stand E3. StoolE4. Over bed tableE5. Mobile work stationE6. Linen hamperE7. Sharps/GlovesE8. Hand sanitizer stationE9. Infectious wasteE10. Patient bed

8’x12’

CONCEPT / NOT TO SCALE

8’X12’ CONTAINER TYPICAL LAYOUT

Page 5: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

E9E8 E7

E11

E12

E1

E2

E5

E6

E9

E3

E10E4

E8 E7

NO

TO

ILET

OPT

ION

AL T

OIL

ET

E1

E2

E5

E6

E3

E10E4

CONCEPT / NOT TO SCALE

ENGINEERING CHANGES

• Field modified isolation room entry door • Add louver with gravity damper and balancing damper• Add exhaust fan with HEPA filtering• Add mounted lighting• Add emergency back-up power• Add electrical and data outlets• Add washable wall and floor covering

NEW EQUIPMENT

E1. Ventilator capable: Storage CabinetE2. Telemetry/Pump on IV Stand E3. StoolE4. Over bed tableE5. Mobile work stationE6. Linen hamperE7. Sharps/GlovesE8. Hand sanitizer stationE9. Infectious wasteE10. Patient bedE11. Patient toilet (optional)E12. Patient sink (optional)

8’X16’ CONTAINER TYPICAL LAYOUT

VIEW

WAL

LVI

EW W

ALL

Page 6: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

LIGHTING

PATIENT BED

LIGHTING

PATIENT BED

DOORDOOREXHAUST FANEXHAUST FAN

DUCT (IF REQUIRED)ELECTRICAL, COMMS, ETC

SUPPORTS

CONCEPT / NOT TO SCALE

LOUVER LOUVER

NOTES

• Louver may be placed on ceiling or wall depending on orientation.• Louver should close when exhaust fan is off.• Provide manual balancing damper for louver.• Utility chase may not be required depending on orientation.• This concept assumes units will be placed inside a conditioned space.

UTILITY LAYOUT BACK-TO-BACK (12’ OR 16’)

Page 7: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

• Materials are readily available nationwide• Fabricated in a local warehouse and transported to the

final location• Units can be fabricated and organized in the warehouse

for efficient setup.• This method allows for an assembly line approach

increasing productivity.• This allows for continuous fabrication with simultaneous

setup• Delivered and setup with the use of flat bed truck with

hoist/crane to reduce manhandling of panels.

A2HC- BUILT IN PLACE STRUCTURES

NEW EQUIPMENT: Same as Container concept

Rear view with potential exhaust duct

Page 8: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

ARENA PROVIDED- Field house ice machine

ENGINEERING CHANGES

• All typical floor plan additions• Build chases for exhaust and utilities • Construct steps and ramps per unit• Power/Data distribution

SPECIAL MEDICAL EQUIPMENT

• All typical floor plan additions• Nurse call• Patient monitoring• Portable med gases• Pharmacy

SITE REQUIREMENTS FOR ARENA LAYOUTS

Page 9: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

8’X16’ HORSESHOE LAYOUT

SUPPORT

NURSE

PODS

POD

S

POD

S

SUPPORT

NURSE

POD

S

POD

S

PODS

SUPPORT

NURSE

PODS

POD

S

POD

S

SUPPORT

NURSE

POD

S

POD

SPODS

SUPPORT

NURSE

PODS

POD

S

POD

S

SUPPORT

NURSE

POD

S

POD

S

PODS

SUPPORT

NURSE

PODS

POD

S

POD

S

SUPPORT

NURSE

POD

S

POD

S

PODS

• TOTAL: 120 PODS• TOTAL: 8 NURSE STATIONS

Note: Notional only. Local life safety egress distances and ABA/ADA must be coordinated with AHJ.

Page 10: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

NU

RSE

POD

S

NU

RSE

POD

S

POD

S

POD

S

SUPPORT

POD

S

POD

S

NU

RSE

NU

RSE

NU

RSE

NU

RSE

NU

RSE

NU

RSE

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

SUPPORT SUPPORT SUPPORT

8’X16’ ROW LAYOUT • TOTAL: 140 PODS• TOTAL: 10 NURSE STATIONS

Note: Notional only. Local life safety egress distances and ABA/ADA must be coordinated with AHJ.

Page 11: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

8’X12’ HORSESHOE LAYOUT

SUPPORT

NURSE

PODS

POD

S

POD

S

SUPPORT

NURSE

POD

S

POD

S

PODS

SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT SUPPORT

NURSE

PODS

POD

S

POD

S

NURSE

PODS

POD

S

POD

S

NURSE

PODS

POD

S

POD

S

NURSE

POD

S

POD

SPODS

NURSE

POD

S

POD

S

PODS

NURSE

POD

S

POD

S

PODS

• TOTAL: 136 PODS• TOTAL: 8 NURSE STATIONS

Note: Notional only. Local life safety egress distances and ABA/ADA must be coordinated with AHJ.

Page 12: ARENA TO HEALTHCARE CONCEPT (A2HC) – COVID ACUTE …...LOUVER LOUVER NOTES • Louver may be placed on ceiling or wall depending on orientation. • Louver should close when exhaust

8’X12’ ROWS LAYOUT

NU

RSE

NU

RSE

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

POD

S

POD

S

SUPPORT

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

NU

RSE

NU

RSE

POD

S

POD

S

POD

S

POD

S

SUPPORTSUPPORTSUPPORTSUPPORT

• TOTAL: 154 PODS• TOTAL: 12 NURSE STATIONS

Note: Notional only. Local life safety egress distances and ABA/ADA must be coordinated with AHJ.