54
Operating Instructions http://www.fujiimpulse.co.jp FA Series Automatic Impulse Sealer Printed JAN 2011 2nd Edition 2.01E

Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Operating Instructions

http://www.fujiimpulse.co.jp

FA Series

Automatic Impulse Sealer

Printed JAN 20112nd Edition 2.01E

Page 2: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA Series Operating Instructions Ver2.01E

Page 3: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

This manual is designed to cover machines of various voltages and plug configurations

About the warning labels

Foreword

The warning labels indicate when there is a danger of injury to the operator or damage to the ma-chine.

Below is a list of what each label denotes.

Caution Minor injuries or damages to the unit may occur when the instruction is ignored.

Warning Critical injuries or fatal accidents will almost certainly occur when the instruction is ignored.

Danger Critical injuries or fatal accidents will almost certainly occur when the instruction is ignored.

Attention! Important Notes and Restrictions - Read the directions in order to avoid misuse of the unit.

TIPS Great Tips and References when using the unit - Highly recommend reading through the information.

Before using, always verify the voltage specification of your particular unit and operate it at the correct voltage.

Please note the following:

1) The voltage specification of your unit is listed on the label which displays the serial number. This label can be found on the machine body.

2) The explanations and illustrations in this operators' manual utilize the following standard plug configurations most common in Japan. However, due to the various configurations in use worldwide, these may not necessarily correspond with the one attached to your specific unit.

100V15A以下

200V20A

100V20A

200V30A

100V20A、30AWarning Voltages and plug configurations differ according to various worldwide specifications.

Always verify those of your particular unit before beginning operation. Connecting the power cord to an outlet of a different specification is extremely hazardous.

Thank you for purchasing the Fuji Impulse FA series sealer. Please read all of the safety and operating instructions before operating this machine. Periodic maintenance and proper operation are necessary to ensure safety when using this impulse sealer.Keep this manual on hand when operating the sealer. Set the heating time according to the material and thickness of the film. As a result of research to further improve the FA series, some details in the operating instructions may differ from your actual machine. For operating problems or product information, please contact your local dealer or fax Fuji Impulse at (81)6-6335-1828.

FA Series Operating Instructions Ver2.01E

3

Page 4: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Table of contents1 Specification ………………………………………………………………………………………… 5

2 Package contents …………………………………………………………………………………… 6

3 Replacement parts …………………………………………………………………………………… 7

4 Proper use of the sealer …………………………………………………………………………… 7

5 Warning-caution label location and content …………………………………………………… 8

6 Operating precautions ……………………………………………………………………………… 9For safety operation…………………………………………………………………………………………………………………………… 9

For smooth operation ……………………………………………………………………………………………………………………… 11

Other safeguards …………………………………………………………………………………………………………………………… 12

7 Major parts and function ………………………………………………………………………… 13

8 Proper use of the sealer ………………………………………………………………………… 148-1 Setting the machine ………………………………………………………………………………………………………………… 14

8-2 Mounting the table ………………………………………………………………………………………………………………… 14

8-3 Insert the air hose…………………………………………………………………………………………………………………… 15

8-4 Plugging in the electrical power cord. …………………………………………………………………………………………… 15

8-5 Power switch ON …………………………………………………………………………………………………………………… 16

8-6 Select the operation mode ………………………………………………………………………………………………………… 16

How to set each operation mode …………………………………………………………………………………………………… 17

8-7 Setting the sealing condition with the control unit ……………………………………………………………………………… 17

8-8 Adjust the seal pressure …………………………………………………………………………………………………………… 20

8-9 Perform test sealing ………………………………………………………………………………………………………………… 20

8-10 Seal with the selected operation mode …………………………………………………………………………………………… 21

8-11 Finishing sealing …………………………………………………………………………………………………………………… 22

8-12 Counter reset………………………………………………………………………………………………………………………… 22

8-13 Power switch OFF ………………………………………………………………………………………………………………… 22

8-14 Inspection after operation ………………………………………………………………………………………………………… 22

9 Replacing the routine maintenance parts …………………………………………………… 239-1 Preparation ………………………………………………………………………………………………………………………… 23

9-2 Sliding the Teflon sheet …………………………………………………………………………………………………………… 24

9-3 Replacing the heating element …………………………………………………………………………………………………… 25

9-4 Replacing the glass tape and Sarcon sheet……………………………………………………………………………………… 27

9-5 Replacing the silicone rubber ……………………………………………………………………………………………………… 28

9-6 Replacing the pressure rubber …………………………………………………………………………………………………… 28

9-7 Replacing the microswitch ………………………………………………………………………………………………………… 29

10 Adjusting each part ……………………………………………………………………………… 3010-1 Adjusting the seal pressure………………………………………………………………………………………………………… 30

10-2 Table switch plate actuator pressure adjustment ……………………………………………………………………………… 30

11 About the optional hot stamp printer ………………………………………………………… 31

12 Electric diagram …………………………………………………………………………………… 32

13 Common problems and solutions ……………………………………………………………… 34Exploded view and spare parts list ……………………………………………………………………………………………………… 37

FA Series Operating Instructions Ver2.01E

4

Page 5: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Code ModelVoltage

VPower

W

Sealing Width mm

Sealing Length mm

Weightkg

Machine Dimention mm

W x D x H

Printer Special Table

Standard Table

Table Switch-plateInner Outer

- FA-200-10 110 1150 10 200 16 260x580x360 ---

- FA-200-10W (D) 110 1450 10 200 17 260x580x360 ---

- FA-300 110 1100/520 5/2 300 16 360x580x360

- FA-300-5W (D) 110 1150 5 300 17.5 360x580x360 ---

- FA-300-10 110 1500 10 300 16.5 360x590x360

- FA-300-10W (D) 110 1500 10 300 18 360x590x360 ---

- FA-450-5 110 1200 5 450 15 520x510x360 ---

- FA-450-5W (D) 110 1350 5 450 16.5 520x380x360 --- ---

- FA-450-10 220 2200 10 450 16 520x380x370 ---

- FA-450-10W (D) 220 2200 10 450 18 520x380x370 --- ---

- FA-600-2 110 1050 2 600 19 680x370x360 --- ---

- FA-600-5 110 1500 5 600 19 680x390x360 --- ---

- FA-600-5W (D) 110 1500 5 600 21.5 680x390x360 --- --- ---

- FA-600-10 220 2700 10 600 23.5 680x380x370 --- ---

- FA-600-10W (D) 220 2700 10 600 24.5 680x380x370 --- --- ---

1 Specification

...Standard equipped ...Optional

FA Series Operating Instructions Ver2.01E

Optional special table can be mounted only when it is used along with the FA stand.

5

Page 6: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

富士インパルス

Model Accessories

FA-200-10 Heating element/ 5pcs, Philips screwdriver, Table-switch plate (with air pedal), Seal gauge

FA-200-10W (D) Heating element/ 5pcs, Philips screwdriver, Table-switch plate (with air pedal)

FA-300 2 & 5mm-width heating element/ 5pcs each, Philips screwdriver, Seal gauge, Table-switch plate (with air pedal)

FA-300-10 Heating element/ 5pcs, Philips screwdriver, Seal gauge, Table-switch plate (with air pedal)

FA-300-5W, 10W (D) Heating element/ 5pcs, Philips screwdriver, Table-switch plate (with air pedal)

FA-450-5 Heating element/ 5pcs, Philips screwdriver, Seal gauge, Standard table, Air pedal

FA-450-10 Heating element/ 5pcs, Philips screwdriver, Seal gauge, Air pedal

FA-450-5W, 10W (D) Heating element/ 5pcs, Philips screwdriver, Air pedal

FA-600-2, 5, 10 Heating element/ 5pcs, Philips screwdriver, Air pedal, Seal gauge

FA-600-5W, 10W (D) Heating element/ 5pcs, Philips screwdriver, Air pedal

Please make sure that all of the accessories described below are included.If not, please contact your dealer.

2 Package contents

Options

These illustrations are not reduced equally.

Heating element

Philips screwdriver

Seal gauge

Table-switch plate

Standard table

Air pedal

Special table

FA stand

(Only for single side heating models.)

(Air pedal is mounted to the table-switch plate at the time of factory shipment.

(Optional product except for FA-450-5.)

FA Series Operating Instructions Ver2.01E

6

Page 7: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Parts Name Sales Unit

Heating element 20 pcs./set or 10 pcs./set

Teflon 2 pcs./set

Silicone rubber 2 pcs./set

Glass tape 5M or 10M roll ... 1 roll

Sarcon sheet 2 pcs./set or 5M roll ... 1 roll

Plastic nut black 6mm 5 pcs./set

Microswitch 1 pc.

Microswitch cover 1 pc.

Models Heating element Silicone rubber Teflon Glass tape Sarcon sheet

FA-200-10, FA-200-10W (D)

FA-300, FA-300-10

FA-450-5, FA-450-10

FA-600-2, FA-600-5

FA-600-10

3 pcs. 1 pc. 2 pcs. 5M roll/ 1roll 1 pc.

FA-300-5W (D), FA-300-10W (D)

FA-450-5W (D), FA-450-10W (D)

FA-600-5W (D), FA-600-10W (D)

5 pcs. 1 pc. 2 pcs. 5M roll/ 1roll 1 pc.

Routine maintenance parts, which will need to be replaced after extensive use, are sold individually as detailed below. Also the maintenance parts kits that includes all the consumable parts are available. Replacement parts can be purchased through your local Fuji Impulse dealer.

1 The impulse sealer is a machine which sends strong electric current quickly to the thin ribbon heater, which presses against the film and instantly heat seals the package. Though this machine yields superior quality sealing, it is not compatible with films thicker than that indicated in the diagram below, sponge-like sheets, and materials which are not able to withstand high heat.

2 Film thickness limits for the FA series are described below. The machine cannot seal bags which are thicker than that indicated. The machine may malfunction if you try to exceed the limits of the machine.

3 Replacement parts

4 Proper use of the sealer

Replacement parts sales unit

Maintenance parts kit detail

FA Series Operating Instructions Ver2.01E

7

Heating method Heater width Film thickness (total thickness of piled film)

Single side heating 2mm Less than 0.3mm

Single side heating 5mm Less than 0.3mm

Single side heating 10mm Less than 0.4mm

Double side heating 5, 10mm Less than 0.5mm

Page 8: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Do not place your fingers near the seal surface. They may get jammed.

●The seal surface will become hot after prolonged use. Do not touch or burns may result.

●Always unplug before performing maintenance.

HOT WARNINGCAUTION

W2079

5 Warning-caution label location and contentWarning - Caution labels are placed in locations where there is a danger of injury to a person or damage to the machine. Label location details are illustrated below. Please check them before beginning operation. Labels not readily apparent are indicated by dotted lines.

This label is adhered to the bottom plate.

When opening the cover for maintenance checks, the machine must unplug from the wall outlet. Otherwise jamming or electrick shock may occure.

CAUTION

UNPLUG BEFORE PERFORMING MAINTENANCE.

Adhered on the left side of the body frame.

WARNING�electric shock

When removing the control unit, you will see this label adhered on the backside of it. Do not remove the control unit unless it is necessary.

This label is adhered on the pressure lever.

If Warning - Caution labels peel off or are lost, please purchase the proper la-bels and place them in the appropriate location.

FA Series Operating Instructions Ver2.01E

8

Page 9: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

6 Operating precautionsFor safety operation

Warning In an emergency, unplug the power cord immediately

This sealer incorporates a number of safety devices and is carefully designed to prevent fires or other malfunctions. However, should all of the safety devices fail simultaneously, there is a possibility of the Teflon catching fire due to a failure of the heating circuit's tripping mechanism that results in the heating element overheating. Should smoke or fire appear from the Teflon, immediately release the foot pedal or turn OFF the power.

Warning Confirm proper electric power source

Make sure power source has the specified voltage and electric power as explained in “1 Specification” of this manual. DO NOT use an extension cord, as the machine may malfunction due to voltage drop or may result in fire. Machine will malfunction if connected to anything other than the specified voltage. Insert the electric power plug fully into the wall outlet.

Warning Do not use for packaging liquids

Do not splash water on the machine or use machine for packaging liquids since machine is not waterproof. There is a danger of electrocution or malfunction of the machine.

Warning Do not insert any metal objects into the sealing area

Please do not place any metal objects into the sealing area during operation. This could cause electrocution.

Warning When replacing parts, unplug the power plug

Maintenance of the machine is important. Parts should be replaced in accordance with the operating instructions. There is a risk of danger if the parts are not replaced properly. Before replacing parts, unplug the machine from the power source and replace parts referring to “Replacing the routine maintenance parts” thoroughly.

Warning Do not modify the machine

Modification of the FA series or the use of unspecified parts may not only lead to damage of the machine, but there is also a risk of danger to the operator. Please do not tamper with the machine. Accidents or damage caused by modification by the customer is the sole responsibility of the customer.

FA Series Operating Instructions Ver2.01E

9

Page 10: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Caution Do not use in the following places

Do not operate machine in the following places since there is a danger of malfunction:

1 Dusty locations.2 Locations not within normal temperatures.

3 Locations with high humidity.

Warning Do not use parts other than those specified

When replacing parts, always use only specified parts sold through Fuji Impulse. Not responsible for malfunctions caused by the use of unspecified parts.

Warning If the power switch automatically turns to the OFF position

If after 3 seconds heating is not complete after it has been initiated, the power switch will automatically turn OFF. There is a possibility of malfunction of the machine. Do not operate the machine until the cause of the shut down is ascertained and the problem has been addressed.

Caution Do not place hands in the sealing area

1 With prolonged use, the sealing area will retain heat and become hot. If you place your fingers in this area, there is a possibility of burns.

2 Do not place hands between the seal jaws (pressure lever and seal frame).

3 Should the foreign objects such as fingers are clamped between the sealing area and the sealer cannot move to the heating process within 0.8 seconds, the lever automatically returns to the initial position. However, the strong pressure is applied especially to the both ends to the sealing area, and there a danger that the sealing process may start without notice.

Caution Use the machine properly

Read “Proper use of the sealer” in this manual carefully and operate sealer correctly. Accidents or damage caused by misuse of the machine not in accordance with the operating instructions are the sole responsibility of the customer.

FA Series Operating Instructions Ver2.01E

10

Page 11: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

For smooth operation

● To achieve a strong seal

Proper sealing pressure is important in achieving a strong seal. Sealing pressure for FA series can be adjusted by the power to depress the pedal. Apply the optimum pressure when sealing.

● When operating machine for extended periods of time

The machine's temperature will rise upon prolonged use of the machine. As the temperature of the machine rises, the condition of the seal will change. Thus, heating time should be shortened and cooling time should be lengthened accordingly.

● Dust in the sealing area

Dust will prevent attainment of a smooth seal. It could also cause damage to heating element and/or other routine maintenance parts. Before using the machine, clean the sealing area.

● Heating time should be set at a minimum

Set sealer so that an acceptable seal is completed in the least amount of heating time. Excessively long heating times (increasing the heat setting unnecessarily) will damage the Teflon, glass tape and other consumables, as well as result in heating element breakage. This will lead to decreased work productivity and unnecessary power consumption.

● Allow sufficient cooling time

Cooling time is important when using an impulse sealer. After the film is heated, the film must cool with the frame and pressure lever in the closed position. Take the cooling time 1.5 times longer than the heating time. For the detail, please refer to “8-7 Setting the sealing condition with the control unit”.

● When the Teflon, silicone rubber becomes damaged

The Teflon, silicone rubber will start to wear with use. Once they are damaged, it will be difficult to achieve smooth and strong seals. Thoroughly read how to replace the parts and be careful when doing so.

FA Series Operating Instructions Ver2.01E

11

Page 12: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Do NOT attempt to plug any other electronic devices into this outlet.

Other safeguards

The power cord from the heater section (white)

Power cord of the printer (black)

●Run test trials before beginning operation

Achieving a superior seal with an impulse sealer is determined by heating / cooling / pressure strength. Depending on the type of film being used and the contents of the bag, heating / cooling / pressure strength conditions may drastically differ. Find the optimum sealing conditions by conducting seal tests before proceeding.

● The Fuji Impulse FA series is an impulse sealer

Do not become alarmed if the sealing area does not become hot after the power switch is turned to the ON position. The machine has not malfunctioned.The Fuji impulse sealer uses an impulse method so the heating element will not become hot just by plugging the unit in or turning the power switch to the ON position. The heater will only become hot for an instant when the heating process is in operation. However, after extended periods of use, the sealing area may become hot.

● Printer outlet

The printer outlet is located on the underside of the seal frame head. It is to be used ONLY when mounting the optional printer.

FA Series Operating Instructions Ver2.01E

12

Page 13: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Arrows▲ and ▼increase or decrease the numeric value by one digit every time they are pushed.If you hold the button in, the numeric value will increase or decrease continuously. Use this method when making wide range changes in setting.

7 Major parts and function

Control Unit Panel

Display

Pressure adjusting nut

Pressure adjusting nut mounting screw

Pressure lever

Electrode

Plastic nut (black)

Teflon

Table switch plate

Air pedal

Body frame air switch with elbow joint

Power cord

Power switch

Control unit1. Turns on when

the power is on.2. Displays each set

value.

Adjust the seal pressure depending on the packaging material thickness.

Depress the air pedal to start operation.

1. Adjust the heating time depending on the thickness and type of film.

The greater the set value is, the longer the heating time will be.

2. Set the cooling time. The greater the set value is, the longer

the cooling time will be.3. Set the auto interval time.4. Turn ON or OFF the auto cycle interval

mode.

Push to turn ON the sealer.Push again to turn OFF.

Digital DisplayMode indicator lights

Mode selection buttonAllows for changes in the mode setting.

Numerical setting arrows

Auto cycle START/STOP

ABORT CYCLE

Counter and setting display

Setting can be increased or decreased during counter mode... COUNTER RESET

All operations are stopped and the sealer returns to the initial position.

The table switch plate can be mounted to the FA-200 and FA-300 series and can be activated by setting the air pedal.(The air pedal is set to the table-switch plate at the time of factory shipment.)

FA Series Operating Instructions Ver2.01E

13

Page 14: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA series is the table-top type sealer. Place the machine on a flat, horizontal working table.The optional FA stand is available when you cannot secure the proper working place.

A Mount the table-switch plateSkip this procedure when using the air pedal as a foot switch.

1 FA-200, FA-300 Series

Fix the table-switch plate to the body frame using the wing nut. The height can be adjusted to the optimum level depending on the application. (The wing nut is installed to the bolt of the body frame where the table is installed.)

2 FA-450, FA-600 Series

The table-switch plate cannot be mounted to these sealer models. (Refer to "8-6 Select the operation mode >>> How to set each operation mode.")

B Mount the standard tableFor the FA series of sealers, the standard table will be optional parts except for FA-450-5.Fix to the seal frame using the wing nuts and bolts. The height can be adjusted to the optimum level depending on the application.

Use only as described in this manual. There is a risk of danger and malfunctions may result if the machine is used not in accordance with this manual.

8 Proper use of the sealer

8-1 Setting the machine

8-2 Mounting the table

Table-switch plate

Air pedal

Wing nut

Body frame

Wing nut

Table Seal frame

A Table-switch plate

B Standard table

FA Series Operating Instructions Ver2.01E

14

Page 15: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Insert the air pedal hose securely into the elbow of the main frame air switch.

C Mount the special table (Optional)The special table can be mounted to the FA stand, which is sold individually. (The air pedal cannot be installed to the special table.)

8-3 Insert the air hose

8-4 Plugging in the electrical power cord.

Special table

FA stand

C Special table

Body frame air switch with elbow joint

Air hose

Securely insert the hose

The power cord is located on the right side of the machine, when facing toward it. Make sure the electrical outlet has adequate current carrying capacity as described at “1. Specification.” Insert the electric power plug fully into the wall outlet.

Warning There is a danger of fire if the electrical power source does not meet proper specification.

FA Series Operating Instructions Ver2.01E

15

Page 16: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

● Auto-cycle interval mode OFF (Auto cycle interval lamp OFF)

1 Air pedal operation ..... The machine operates when the air pedal is depressed.

The control unit display will turn on when the power switch, located on the side of the common frame, is pushed on.

The "Auto cycle START/STOP" button allows you to select between manual and continuous automatic operation. Turn ON or OFF the auto-cycle interval mode after selecting the operation mode referring to "8-7 Setting the sealing condition.”For the detail, refer to “8-6 Select the operation mode >>> How to set each operation mode.”

2 Table switch plate operation ..... The machine operates when the table switch plate is pushed.

● Auto-cycle interval mode ON (Auto cycle interval lamp ON)

3 Auto cycle mode ..... Automatic operation takes place based on the preset intervals.

8-5 Power switch ON

8-6 Select the operation mode

Push to turn ON

1 Air pedal operation

2 Table-switch operation

3 Auto-cycle mode

FA Series Operating Instructions Ver2.01E

16

Page 17: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

The heating time, cooling time and auto-cycle interval can be set with the control unit.The setting values will vary depending on the pouch/film material, thickness, etc. Reset the seal conditions every time you change the bag.

Pushing the SET button changes the modes in the following order:COUNTER→HEATING TIME→COOLING TIME→AUTO CYCLE INTERVAL.The mode indicator lights show which mode is currently displayed. If no light is lit, the machine is in the counter mode.

How to set each operation mode

8-7 Setting the sealing condition with the control unit

DIGITAL DISPLAY

MODE INDICATOR LIGHTS

ALLOWS FOR CHANGEDNUMERICAL SETTING ARROWS

AUTO CYCLE START/STOP

Counter and setting display

In the mode setting Setting can be increased or decreased during counter mode... counter reset.

Operation mode FA-200, FA-300 series FA-450, FA-600 series

Air pedal operation

Push the Auto Cycle START/STOP button to turn OFF the auto cycle mode. Remove the air pedal set to the table-switch plate. Place the air pedal on the floor or the other place.

Push the Auto Cycle START/STOP button to turn OFF the auto cycle mode. Set the air pedal included in the accessories referring to "8-3 Insert the air hose".

Table-switch plate

operation

Push the Auto Cycle START/STOP button to turn OFF the auto cycle mode. Mount the table-switch plate referring to "8-2 Mount the table".

Table-switch plate operation cannot be

selected.

Auto-cycle modeSet the auto-cycle interval time. Turn ON the auco-cycle mode by pusing the Auto Cycle START/STOP button.

FA Series Operating Instructions Ver2.01E

17

Page 18: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Setting the auto-cycle interval

● Activate the "auto-cycle interval" mode. Use ▲/▼ arrows to set the interval. [Setting range : (set heating time x 3 times) - 5.0 sec.]

● The interval time for the auto-cycle interval mode is set 3 times longer than the heating time, and cannot be set shorter than that.

When the heating time is made longer, the control unit will automatically adjust the auto-cycle interval time if it is shorter than 3 x heating time.

Setting the heating time● Activate the "heating time" mode. Use ▲/▼

arrows to set the heating time. [Setting range : 0.1 - 1.6 sec. ]

● The optimum heating time will differ depending on the voltage when the machine is used, the thickness and type of film.

● Set the heating time at minimum to make a sufficient seal. This will increase the productivity and also prevent unnecessary power consumption.

Setting the cooling time

● Activate the "cooling time" mode. Use ▲/▼ arrows to set the cooling time. [Setting range : (set heating time) - 5.0 sec.]

● The cooling time should be set1.5 to 2 times longer than the heating time. In order to guarantee sufficient cooling time, the FA series is designed that the cooling time cannot be set shorter than the set heating time.

● When setting the heating time, the control unit will automatically correct the cooling time to the same amount as the set heating time if the heating time is set longer than the cooling time.

FA Series Operating Instructions Ver2.01E

18

Page 19: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Power ON

MODE DIGITAL DISPLAY

SET FIRST TIMEPUSH

PUSH SET SECOND TIME

SET THIRD TIME

RETURN TO COUNTER DISPLAY

DECREASE VALUE INCREASE VALUE

.................

.................

.................

NOTE1 .... Cooling time cannot be set less than the set heating time.

DISPLAY RANGE

NOTE1

.................NOTE2

PUSH

SET FOURTH TIMEPUSH

COUNTER VALUE

HEATING TIME

COOLING TIME

AUTO CYCLE

Set the interval time only when using the auto-cycle interval mode

NOTE2 .... Auto cycle interval cannot be set less than three times the time of set heating time.

POWER ON

MODE

DIGITAL DISPLAY

COUNTER VALUE

HEATING TIME

COOLING TIME

AUTO CYCLE

FIRST TIME

PUSH

PUSH

PUSH

PUSH

PUSH

SECOND TIME

PUSH THIRD TIME

setPUSHING FOUR TIMES WILL

RETURN YOU TO THE COUNTER MODE.

INCREMENTS OF 0.1

INCREMENTS OF 0.1

INCREMENTS OF 0.1

TO RESET THE VALUES

SETTING COMPLETE

HEATING TIME DISPLAY

COOLING TIME DISPLAY

AUTO CYCLE ITNERVAL DISPLAY

set

set

set

Setting the different modes

Example)Settings : Heating 0.8 sec. Cooling 1.2 sec. Auto cycle 2.4 sec.

FA Series Operating Instructions Ver2.01E

19

Page 20: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

The pressure adjusting nut is adjusted to the "NORMAL" position for the film of 0.1 to 0.2 mm thickness at the time of factory shipment.The required sealing pressure varies depending on the type and thickness of the film. Adjust the sealing pressure according to each of the film to be used.

After completing the control unit and seal pressure adjustment, turn off the auto-cycle mode and manually perform the seal test to find the optimum sealing condition for your film.

8-8 Adjust the seal pressure

8-9 Perform test sealing

Pressure adjusting nut

Attention! Perform the pressure adjustment referring to “10-1 Adjusting the sealing pressure.” Change the pressure setting every time you change the film.

FA Series Operating Instructions Ver2.01E

20

Page 21: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

1 Air pedal operationPlace a pouch to the sealing area. Depressing the air pedal will lower the pressure lever to start sealing.

2 Table-swtich plate operationPlace a pouch to the sealing area. Lightly press the part of the table-switch plate where indicated by the label to lower the pressure lever and start sealing.

3 Auto-cycle interval modeAutomatic operation takes place based on the preset intervals. Place a pouch to the sealing area according to the timing that the pressure lever descends. You can deactivate the auto-cycle mode by pushing the Auto-Cycle START/STOP button.

● ABORT CYCLE buttonTo stop the operation after the machine started working, push the “ABORT CYCLE” button. The lever will return to the initial position. The set value will not be erased even if the “ABORT CYCLE” button is pressed.

8-10 Seal with the selected operation mode

1 Air pedal operation

2 Table-switch plate operation

3 Auto-cycle mode

Caution The sealing area become hot with the prolonged use, and there is a danger of burning.

Also, it is extremely dangerous to place fingers to the sealing area where the strong pressure is applied. The machine is designed to release the pressure when the microswitch is not activated within 0.8 seconds due to the foreign objects being inserted to the sealing area. However, the strong pressure is applied especially to both ends of the sealing jaws. Please be careful as the sealer may start heating. (Especially for FA-450 and 600 series.)

FA Series Operating Instructions Ver2.01E

21

Page 22: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

加 熱 中

冷 却 中

連続運転中

連続運転ON/OFF

中 止

加 熱 中

冷 却 中

連続運転中

連続運転ON/OFF

中 止

After the heating and cooling cycle has finished, the pressure lever returns to the initial position, and the sealing is complete. If a sealing is not clean enough, adjust the heating/ cooling time or sealing pressure.

As the sealing operation proceeds, the numeric value of the counter increases one at a time from 0000 to 9999.When you want to reset the counter to 0000, push either ▲ or ▼ arrow buttons while the machine is in the counter mode.

After finishing operation, always turn OFF the power switch.

As the set value and the seal count are retained by the control unit, there is no need to put the value every time after turning OFF the power switch.

Unplug the power outlet in the case of not using the machine for a while.

After use, please clean up the parts. Inspect parts such as Teflon and heating element to make sure that they are not damaged. If the parts appear to be damaged, replace them referring to operating instruction.

8-11 Finishing sealing

8-12 Counter reset

8-13 Power switch OFF

8-14 Inspection after operation

Push to turn OFF

FA Series Operating Instructions Ver2.01E

22

Page 23: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Daily maintenance or replacement of parts at an early stage can prevent the machine from being damaged, and keeps the machine at the optimum condition. Replace parts according to the following directions in order to maintain your machine in optimum operating condition.

The sealing section consists of the parts as in the illustration below. When replacing parts, be careful to arrange the parts exactly in the same order.

●Before replacing partsWhen replacing parts, lift up the pressure lever for easier replacement.

How to lift up the pressure leverTurn the pressure adjusting nut at the center of the pressure lever fully counterclockwise, and remove the pressure adjusting nut. Lift up the pressure lever. For the installment method, please refer to “10-1 Adjusting the sealing pressure >>> Attention! .”

9 Replacing the routine maintenance parts

Structure of the sealing section

9-1 Preparation

Always unplug the machine before maintenance.

Pressure leverSilicone rubber (white)

Teflon

Glass tapeSarcon sheet

Heating element

Glass tape

TeflonHeating element

Double side heating

Pressure leverSilicone rubber

Teflon

Glass tape

Sarcon sheet

Heating element

Single side heating

Pressure adjusting nut

Small lever

Pressure rubber

Pressure lever

Sliding shaft

Warning Always unplug the power plug before replacing parts. There is a danger of electrocution if it has been done without unplugging.

Warning Follow the directions on this manual when replacing parts. Replacing parts in the way ignoring this manual could cause malfunction of the machine as well as electrocution and fire.

Warning Always use only specified parts sold through Fuji Impulse. Unspecified parts may cause malfunction of the machine.

Warning When the pressure lever is lifted up, you can activate the microswitch by clicking it with a thin stick, etc. Do not activate the microswitch as it will start heating and may result in fire if the plug is not unplugged. Please refer to warning of “9-7 Replacing the microswitch.)

FA Series Operating Instructions Ver2.01E

23

Page 24: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Essential tools: Scissors, a Philips screwdriver

Replace when: The Tedlon burns, or when the seal becomes messy.

Teflon is either sold individually or included in the maintenance parts kit. It is rolled to the Teflon roll bar about 25 - 30cm as an extra.

Lower Teflon sheet1 Loosen two black plastic nuts at the front side of

the machine to remove the lower Teflon sheet holding plate.

2 Loosen two black plastic nuts that fix the Teflon roll bar fastening plates so the Teflon roll bar can be moved, and slide the Teflon toward you.

3 Cut the damaged part of the Teflon with scissors.4 Insert the edge of the Teflon between the lower

Teflon holding plate and Teflon sheet holder support. And then fix the lower Teflon sheet holding plate with black plastic nuts.

5 Roll up the Teflon to the Teflon roll bar so it does not get wrinkled.

6 Tighten the black plastic nuts to secure the Teflon roll bar with Teflon roll bar fastening plates.

Upper Teflon sheet (For FA-200, FA-300 double side heating

type)

1 Loosen the screws that fix the upper Teflon sheet holding plate and slid off the edge of the Teflon.

2 Loosen the screws of the Teflon sheet holding brackets so the Teflon roll bar can be moved. Slide the Teflon toward you.

3 Cut the damaged part of the Teflon with scissors.4 Insert the edge of the Teflon between the upper

Teflon sheet holding plate and pressure lever and tighten the screw loosened at procedure 1 to fix the Teflon edge.

5 Roll up the Teflon to the Teflon roll bar so it does not wrinkled.

6 Tighten the screws of the Teflon sheet holding brackets to secure the Teflon roll bar.

9-2 Sliding the Teflon sheet

Teflon roll bar fastening platePlastic nut (black)

Teflon roll bar

Teflon sheet holding plate (lower)

Slide off the Teflon sheet

Plastic nut (black)

Teflon sheet holding plate (upper) Teflon sheet

Teflon roll bar holding bracket

FA Series Operating Instructions Ver2.01E

24

Page 25: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Upper Teflon sheet (For FA-450, FA-600 double side heating

type)

1 Loosen the white plastic nuts at the backside of pressure lever so the Teflon roll bar can be moved.

2 Loosen the screws that fixes the upper Teflon sheet holding plate and slide off the Teflon to the direction of allow.

3 Cut the damaged part of the Teflon with scissors.4 Insert the edge of Teflon between the upper

Teflon sheet holding plate and pressure lever, and tighten the screws to fix the Teflon sheet holding plate.

5 Roll up the Teflon to the Teflon roll bar so it does not wrinkled.

6 Tighten the white plastic nuts to secure the Teflon roll bar with upper Teflon roll bar fastening plates.

Electrodes that mount the heating element consist of parts as in the right illustration.

Essential tools: A Philips screwdriver

Replace when: The heating element breaks, unevenness is generated, or when the

seal becoms messy.The heating element is either sold individually or included in the maintenance parts kit.

Warning If you loose the screw C, do not substitute ones longer than the screw C (M4x6) as there is a danger of short circuit by the longer screw touching screw D.

Warning When replacing the heating element, replace the glass tape and Sarcon sheet as well if they are appear to be damaged. If they are damaged and cannot properly insulate the heating element from the body frame, the short circuit may result.

TIPS The heating element can be replaced without removing the electrode cover so you will not loose the cover or screw.

9-3 Replacing the heating element

Teflon sheet holding plate (upper)

Teflon roll bar fastening plate (upper)

Plastic nut (white)

Teflon roll bar

Electrode mounding bracket

Electrode plate

Electrode plate spring

Electrode cover

Terminal coverScrew A

Screw C(M4x6)

Screw B

Screw D

Mounted only to the single side heating models.

FA Series Operating Instructions Ver2.01E

25

Page 26: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Lower heating element (for all models)

1 Remove the Teflon sheet. (Refer to “9-2 Sliding the Teflon sheet.”)

2 Loosen the screw A of both electrodes with a Philips screwdriver, and remove the terminal covers. The illustration on the right describes the electrode after the terminal cover is removed.

3 Loosen screw B of both electrodes to loosen the tension of the heating element. It is not necessary to remove the electrode covers.

4 Insert a Philips screwdriver into the hole of the electrode cover and loosen screw C. The heating element can be removed.

5 When mounting the new heating element, insert each terminal between the electrode plate and electrode plate spring. While pushing down the terminal with your fingers so it stays in place, tighten the screw C with a Philips screwdriver.

6 Tighten the screw B loosened at the procedure 3 so the heating element is stretched tight. When the screw B is not tightened enough, the heating element will not be stretched tight enough, which may result in damaging the heating element.

7 Fix the terminal covers to the electrodes with screw A.

Upper heating element (for double side heating models)

1 Remove the Teflon sheet. (Refer to “9-2 Sliding the Teflon sheet.”)

2 Loosen the screw B of both electrodes with a Philips screwdriver, and remove the terminal covers. The illustration on the right describes the electrode after the terminal cover is removed.

3 Insert a Philips screwdriver into the hole of the electrode cover and loosen screw C. The heating element can be removed.

4 When mounting a new heating element, insert each terminal between the electrode plate and electrode plate spring. While pushing down the terminal with your fingers so it stays in place, tighten screw C with a Philips screwdriver.

5 Tighten the screw B loosened at the procedure 2 so the heating element is stretched tight. When the screw B is not tightened enough, the heating element will not be stretched tight enough, which may result in damaging the heating element.

Push

Turn while pushing

Teflon sheet

Heating element terminal

Turn

Screw B

Teflon sheet

Heating element

Screw C

Electrode plate spring

Electrodeplate

Screw B

Push

Screw C

Turn while pushing

Electrode plate spring

Electrodeplate

Teflon sheet

Heating element terminal

Teflon sheet

Turn

Heating element

Caution Without loosening the screw B, the heating element will be kept stretched tight. Thus the heating element terminal cannot be inserted between the electrode plate and plate spring.

Caution Without loosening the screw B, the heating element will be kept stretched tight. Thus the heating element terminal cannot be inserted between the electrode plate and plate spring.

FA Series Operating Instructions Ver2.01E

26

Page 27: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Seal area length

About 5mm

About 2mm

About 5mm

About 2mm

Essential tools: Scissors, A Philips screwdriver

Replace when: The heating element breaks often, the seal becomes messy, etc.

The glass tape and Sarcon sheet are either sold individually or included in the maintenance parts kit.

1 Carefully read the respective replacement instructions on the Teflon and heating element and remove all of them.

2 Completely remove the glass tape and Sarcon sheet.

3 Cut the new Sarcon sheet 2mm longer than the seal area for left and right sides and adhere it to the lever.

4 Adhere the glass tape over the Sarcon sheet so it covers the electrode about 5mm.

Attention! Applying the Sarcon sheet and glass tape to a surface with adhesive residues will negatively affect the sealing surface.

Attention! If the adhesive of the Sarcon sheet is weak when replacing the glass tape, please replace the Sarcon sheet as well.

9-4 Replacing the glass tape and Sarcon sheet

Sarcon sheet

Glass tape

Electrode

Adhere the glass tape over the Sarcon sheet.

FA Series Operating Instructions Ver2.01E

27

Page 28: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

3mm

Essential tools: Industrial-purpose alcohol (Ethanol)

Replace when: The seal becomes messy, etc.The silicone rubber is either sold individually or included in the maintenance parts kit.

1 Remove the damaged (old) silicone rubber.2 Using an industrial purpose alcohol, etc.,

completely remove the adhesive residues remaining on the metal portion of the pressure lever.

3 Adhere the new silicone rubber starting from the edge.

Attention! Adhere the silicone rubber carefully as it cannot be reapplied.

Essential tools: N/A

Replace when: The height of the shock absorbing clearance become lower than 2mm. (New pressure rubber has 3mm in height.)

The pressure rubber is sold individually. Please inspect the height of shock absorbing clearance periodically.Lift up the pressure lever referring to “9-1 Preparation” for the easier replacement.

9-5 Replacing the silicone rubber

9-6 Replacing the pressure rubberShock absorbing clearance for the new product

Pressure rubber cross section diagram

Silicone rubber

Pressure lever

Adhere from the edge

Warning New pressure rubber has 3mm-high shock absorbing clearance. The long-term use of the machine could cause the wear-out of the pressure rubber. If the shock absorbing clearance become lower than 2mm, sealing pressure increases and too much pressure can be applied to the sealing area. This is extremely dangerous especially when a finger is caught in the sealing area by any chance.

Inspect the pressure rubber before the operation and replace it if necessary.

FA Series Operating Instructions Ver2.01E

28

Page 29: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

NC

NO

COM

Gray

Yellow

Gray

Gray

Warning If the wiring of the microswitch is not correct, the timer may be damaged. Regarding the triac connection, the label is adhered to the timer.

Warning If you activate the microswitch by pushing it with a thin object, it may bring the heat to the heating element and there is a danger of burning or fire.

Essential tools: A Philips screwdriver

The microswitch is sold individually.

1 Referring to “9 Replacing the routine maintenance parts >>> 9-1 Preparation,” lift up the pressure lever.

2 Loosen the screws that fix the microswitch case to the common frame, and remove the microswitch case.

3 Next, loosen the screws that fix the microswitch, and remove it from the microswitch case.

4 Remove all of the cables.

Installation5 When reattaching the microswitch, wire properly

referring to “12 Electric diagram.” If the wiring is not correct, the timer may be damaged.

Warning Always unplug the power cord from the outlet when replacing the microswitch.

6 Attach the microswitch to the microswitch case removed at the procedure 3 using the screws. Please refer to the illustration on the right for how to install to the microswitch case.

7 Attach the microswitch case to the common frame.

8 Return the pressure lever etc. removed at the procedure 1 to the initial state.

9-7 Replacing the microswitchCommon frame

Microswitch case

Microswitch case

Microswitch

Microswitch case

Microswitch

FA Series Operating Instructions Ver2.01E

29

Page 30: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

When the thickness of a bag is 0.6mm

0.1mm~0.5m

0.1mm~0.2mm

Less than 0.1mm

NO

MA

L

0.1m /m

or less

0.6m

/m

or m

ore

To

read

just

dial

, tur

n it

fully

clo

ckw

ise,

then

turn

itba

ck to

NO

RM

AL.

NOMAL0.1 m/m

or less

0.6m /m

or more

To readjustdial, turn itfully clockwise,then turn itback to NORMAL.

NO

MA

L

0.1m/mor less

0.6m

/mor

mor

eTo

read

just

dial

, tur

n it

fully

clo

ckw

ise,

then

turn

itba

ck to

NO

RM

AL.

NOMAL0.1 m/m

or less

0.6m /m

or more

To readjustdial, turn itfully clockwise,then turn itback to NORMAL.

Adjust the pressure strength indicated on the seal pressure adjusting nut using the pointer on the small lever.

1 Loosen the pressure adjusting nut fastening screw.

2 Turn the pressure adjusting nut to adjust the sealing pressure to a level suited for the thickness of the packaging material used. Use the compatible thickness described on the pressure adjusting nut as guidance. (Turn the pressure adjusting nut fully clockwise as it stops at the pressure for less than 0.1mm, then turn counterclockwise to adjust.)

3 Once the adjustment is made, always use the securing screw to secure the pressure adjusting nut.

When the bag contents are heavy, the table switch may be turned on immediately and activate the sealer. Adjust the table pressure adjustment screw so the table does nor activate the sealer.

10 Adjusting each part10-1 Adjusting the seal pressure

10-2 Table switch plate actuator pressure adjustment

Seal pressure adjusting nut

Pressure adjusting nut

fastening screw

Pressure rubber

Shock absorbing clearance (about 3mm)

Maximum compression (about 2mm)

Table switch plate pressure adjustment screw

The pressure adjusting spring is installed inside the screw.

Seal pressure adjusting nut

Pointer

Small lever

Pressure adjusting nut fastening screw

Pointer Pointer

Warning Operating while the nut is turned excessively clockwise (the direction for handling thinner packaging material) may cause sealing failure or cause the pressure lever to remain at the lowered position due to the solenoid suction strength dropping and the microswitch not being activated. In addition, it is very dangerous due to the excessive pressure. Always operate by following the instructions in the following

Attention! and the setting within the red range described on the label on the adjusting nut.

Warning Operating while the nut is turned excessively counterclockwise (the direction for handling thicker packaging material) will increase the sound of the pressure lever movement.

Attention! What to do if you loosen the pressure adjusting nut too much. In the case you have loosened and caused to remove the pressure adjusting nut at the time of parts replacement:

Turn the pressure adjusting nut fully clockwise so that it stops at [Less than 0.1mm] scale. Then adjust the pointer on the scale for the packaging material. Normally, operation is done in the [NORMAL] position.

FA Series Operating Instructions Ver2.01E

30

Page 31: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

EXP DATE 12.12.10MFG DATE 12.12.00

EXP DATE 12.12.10MFG DATE 12.12.00

● Optional hot stamp printer can be installed to the FA series of sealers.● Manufacturing date and lot number etc. can be printed at the same time as sealing.● There are two types for FEP-N2 series: One is inner printing type that prints below the sealing

surface, and the other is outer printing type that prints above the sealing surface.

11 About the optional hot stamp printer

You can choose either 1 or 2-line printing by changing the setting.

Inner printing Outer printing

Sealing surface

Models Inner Printer Outer Printer

FA-200-10 FEP-N2 ×

FA-200-10W (D) FEP-N2 ×

FA-300, FA-300-10 FEP-N2 FEP-OS-N2

FA-300-5W (D), FA-300-10W (D) FEP-N2 ×

FA-450-5, FA-450-10 FEP-N2 FEP-OS-N2

FA-450-5W (D), FA-450-10W (D) FEP-N2 ×

FA-600-2, FA-600-5, FA-600-10 FEP-N2 FEP-OS-N2

FA-600-5W (D), FA-600-10W (D) FEP-N2 ×

FA Series Operating Instructions Ver2.01E

31

Page 32: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Cooling FAN

Microswitch

DC solenoid

Heating elementElectrode

Transformar

Air pedal

Air switch

110V outletfor FEP

Control unit

COMMON

OPEN

Power cord

Power switch

Red

Red

BlackBlack

Gray

GrayBrown

Brown

Yellow

Gray

Gray

Black Black

Black

Black

Black

Black

Red

Gray

Fuseholder

15A

Double heating type

Thermister

(Blue fordouble type)

5 3

46

Gray

Red

Triac

12 Electric diagram

110V

FA Series Operating Instructions Ver2.01E

32

Refer to the exploded view and spare parts list for the electric parts.

Page 33: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Cooling FAN

Microswitch

DC solenoid

Heating elementElectrode

Transformer

Air pedal

Air switch

Control unit

COMMON

OPEN

Power switch

White

White

BlackBlack

White

WhiteBrown

Brown

Yellow

Red

Gray

Gray

Black Black

Black

Black

Black

Black

Red

Gray

FUSEHolder

15A

Double heating type

Thermister

(Blue fordouble type)

5 3

46

Blue

Blue

Gray

Gray

Transformarfor FEP

200V

100V

100V outletfor FEP

Gray

Earth

Green

White

Black

Triac

WhiteBlack

Green(Earth)

220V

Refer to the exploded view and spare parts list for the electric parts.

FA Series Operating Instructions Ver2.01E

33

Page 34: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Problems Check Solutions

The digital display does not turn ON even

after turning ON the power switch.

Does the electricity come to the outlet? Make sure the electricity flows to the outlet.

Is the power plug fully plugged in? Insert the power plug fully to the outle.

Is the power plug damaged? *Replace the power cord or power plug.

Is the fuse on the back of the control unit

blown?Replace the fuse.

When stepping on the air pedal, the

pressure lever does not descend even

when the auto cycle is OFF. (With beep

sound)

When stepping on the air pedal, does it click

from the microswitch accommodated in the

body frame air switch?

In case it does not click:

→*Replace the body frame air switch.

In case it clicks:

→*Replacement of the control unit is

necessary.

-----*Defects in the control unit are assumed.

Replacement is necessary.

When stepping on the air pedal, the

pressure lever does not lower even when

the auto cycle is OFF. (No beep sound)

-----* Defects in the control unit are assumed.

Replacement is necessary.

Is the air hose securely inserted to the body

frame air switch?

Securely insert the air hose to the elbow

joint of body frame air switch.

In case it is securely inserted:

→*Replacement of the control unit is

necessary.

Heating lamp turns on, but there is no heat

and sealing is not performed.

Is the heating element servered? Replace the heating element.

Is there bad connection between the

electrode and the heating element?

Polish the metal area where the electrode

and the heating element meet with the sand

paper.

Is the black (blue) wire from the transformer

to the electrode disconnected?

* Securely attach the black (blue) wire from

the transformer to the electrode.

-----* Defects in the triac of control unit are

assumed. Replacement is necessary.

If you are experiencing problems with the machine, please refer to the chart below.Carefully follow the directions in the operating instructions when replacing parts.Please consult your dealer or Fuji Impulse if after referring to the chart, the problem cannot be resolved. Please refer any questions regarding replacement of parts not listed in the operating instructions or adjustment of such parts to your dealer or Fuji Impulse.Items marked with an asterisk ※ in the “Solutions” column refer to the fact that these problems should be addressed by an electrician. If there are any problems, please contact your dealer or Fuji Impulse.

Warning Always unplug the power plug before replacing parts.

13 Common problems and solutions

FA Series Operating Instructions Ver2.01E

34

Page 35: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Problems Check Solutions

Heating element breaks easily .

Is the set heating time too long?Set the heating time at minimum required to

make a sufficient seal.

Is the cooling time too short? Allow sufficient cooling time.

Is the glass tape and/or Sarcon sheet

damaged?Replace the glass tape and/or Sarcon sheet.

Heating element is convex and liable to

break at the center.Is the electrode damaged? * Replace the electrode.

Sealing is not clean.

Have the pressure lever and seal frame

become hot?

(As the temperature of the pressure lever

and frame rises, the film may melt without

changing the heating time.)

Wait until the pressure lever and frame

being cooled off, and take enough operation

interval.

Is the Teflon sheet, glass tape, Sarcon sheet

or silicone rubber damaged?

Replace the Teflon sheet, glass tape,

Sarcon sheet or silicone rubebr.

Is the cooling time too short? Allow sufficient cooling time.

Is the pressure setting suitable for the

thickness of your pouch?Precisely adjust the sealing pressure.

Sealing finish differs on the right and left

side.

Is the surface of the silicone rubber uneven? Replace the silicone rubber.

When the pressure lever is lowered, do you

recognize the gap between the pressure lever

and seal frame?

If you do, please contact your local dealer

or Fuji Impulse as the machine needs to be

repaired.

The power switch automatically turns

OFF. -----

* The control unit may be broken. Replace

the control unit.Heating lamp continues to be ON and the

heating element and Teflon burn.

The following error numer is displayed

-----

* The microswitch may be broken. Replace

the microswitch.The following error numer is displayedThe error message appears when the

microswitch is turned OFF during the

heating process.

The following error numer is displayed

-----

After restarting the machine by turning

OFF and On the machine, set the sealing

condition again

Solutions marked with an asterisk * mark should be addressed by electrician or experts in replacing electric parts. If you have any troubles is solving the problems, please contact with your local dealer or Fuji Impulse.

FA Series Operating Instructions Ver2.01E

35

Page 36: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA Series Operating Instructions Ver2.01E

36

Page 37: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

When ordering spare parts, please consult the exploded view

diagram/spare parts list on the following pages and provide both

the part name and code number to your local dealer.

Exploded View Spare Parts list

FA Series Operating Instructions Ver2.01E

37

Page 38: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

加 熱 時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

@7@7

6

4

7 5

ba

a

a

b

b

b

c

a

a

=

8

2

1

2

310

17

45

48

4636

37

73

25

2426

23

72

50

44

43

32

32

32

49

21

20

38

40

39

4241

3335

55

302914

13

13

19

56

61

60

51

50

53

59

58

57

66

6263

16

15

1918

17

9

FA-200-10 Exploded View G Type FA-200-10

38

Page 39: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-200-10 Spare Parts List G Type FA-200-10

39

*Pressure lever complete set/ Code 24210D for single heating type consists of numbers 1 , 2 , 4 - 10 , 51 .

Parts Code No. Parts name Sales unit

1 24200 Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24299 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

9 33230B Silicone rubber 2 pcs/set

13 33031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 33210 Teflon sheet 1 pc.

19 a,b 33200 Teflon sheet holder support (with screw, nut) 1 pc.

20 33005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 33240 Heating element (L-shaped terminal) 20 pcs./set

59016 Heating element (L-shaped terminal) 10 pcs./set

24 33192 Teflon sheet 2 pcs/set

25 33193 Teflon sheet roll bar 2 pcs/set

26 33191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

30 421702B Terminal cover (with Screw) 2 pcs/set

32 a,b,c 30032B Common frame (S) 1 pc.

33 39141B # Microswitch 1 pc.

35 39142 # Microswitch case 1 pc.

36 30530 Tramsformer mounting frame 1 pc.

Parts Code No. Parts name Sales unit

37 ----- Transformer (with core cover) 1 pc.

38 27350 Transformer core cover 1 pc.

39 30130 Transformer cover 1 pc.

40 33131 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 ----- Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 ----- Power switch 1 pc.

46 ----- Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24291 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 ----- Solenoid set 1 set

55 ----- Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

62 24341 Table switch plate 1 set

63 24345 Table switch plate spring 2 pcs/set

66 24342 FA pedal holder (with nut) 1 pc.

Page 40: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

a

=

加 熱 時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

6

4

7 5

b

b

c

a

1a2

8

b

a

b

229

64

65

12

21

23

45

36

37

38

39

40

46

48

4241

43

32

32

32

44

50

4955

56

56

50

51

53

61

60

58

59

6362

66

16

15

14

13

13

19

72

23

29

24

25

73

17

26

21

20

3335

1918

17

3

26

FA-200-10 Exploded View F Type FA-200-10W

40

Page 41: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-200-10W (D) Spare Parts List F Type FA-200-10W

41

*Pressure lever complete set/ Code 24215D for double heating type consists of numbers 1 , 2 , 4 - 8 , 12 , 21 , 23 , 26 , 29 , 51 ,

64 , 65 .

Parts Code No. Parts name Sales unit

1 24201 Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24299 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

12 33531 Silicone rubber (white) 2 pcs/set

13 33031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 33210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 33200 Teflon sheet holder support (with screw, nut) 1 pc.

20 33005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 33240 Heating element (L-shaped terminal) 20 pcs./set

59016 Heating element (L-shaped terminal) 10 pcs./set

24 33192 Teflon sheet 2 pcs/set

25 33193 Teflon sheet roll bar 2 pcs/set

26 33191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

32 a,b,c 30033B Common frame (W) 1 pc.

33 39141B # Microswitch 1 pc.

35 39142 # Microswitch case 1 pc.

36 30530 Tramsformer mounting frame 1 pc.

Parts Code No. Parts name Sales unit

37 ----- Transformer (with core cover) 1 pc.

38 33355 Transformer core cover 1 pc.

39 33130 Transformer cover 1 pc.

40 33132 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 ----- Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 ----- Power switch 1 pc.

46 ----- Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24291 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 ----- Solenoid set 1 set

55 ----- Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

62 24341 Table switch plate 1 set

63 24345 Table switch plate spring 2 pcs/set

64 33215 Upper Teflon sheet holding plate (w/ screw, spring) 1 pc.

65 39497 Upper Teflon sheet holding bracket 2 pcs/set

66 24342 FA pedal holder (with nut) 1 pc.

Page 42: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

@7

加熱時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

6

4

7 5

b

a

b

a

b

b

c

a

=

a

3

9

22

1

8

4532

32

32

48

46

49

44

50

55

17

73

2625

2423

72

21

20

1918

3533

43

36

37

40

38

39

4241

19

3029

13

13

14

15

16

56

57

61

50

51

53

59

58

60

66

6263

17

FA300 S Exploded View G Type FA-300

G Type FA-300-10

42

Page 43: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-300 S Spare Parts List G Type FA-300

G Type FA-300-10

43

*Pressure lever complete set/ Code 26 for single heating type consists of numbers 1 , 2 , 4 - 9 , 51 .

Parts Code No. Parts name Sales unit

1 24300 Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24299 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

9 3 Silicone rubber 2 pcs/set

13 30031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 30210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 30200 Teflon sheet holder support (with screw, nut) 1 pc.

20 30005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

Heating element (L-shaped terminal) 10 pcs./set

24 30192 Teflon sheet 2 pcs/set

25 30193 Teflon sheet roll bar 2 pcs/set

26 30191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

30 421702B Terminal cover (with Screw) 2 pcs/set

32 a,b,c 30032B Common frame (S) 1 pc.

33 39141B # Microswitch 1 pc.

35 39142 # Microswitch case 1 pc.

36 30530 Tramsformer mounting frame 1 pc.

Parts Code No. Parts name Sales unit

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 15 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 ----- Power switch 1 pc.

46 ----- Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24291 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 ----- Solenoid set 1 set

55 ----- Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

62 24341 Table switch plate 1 set

63 24345 Table switch plate spring 2 pcs/set

66 24342 FA pedal holder (with nut) 1 pc.

Special Parts ListCode Parts Name FA-300 FA-300-10

3 Silicone rubebr 30230B 34230B

7Heating element (20pcs/set)

30247(2mm width)30246(5mm width)

34240

Heating element (10pcs/set)5902059022

59024

12 Transformer - -

13 Transformer core cover 30350 32350

14 Transformer cover 30130 27130

15 Transformer fastening screw 30131 32131

16 Powre cord - -

26 Pressure lever complete set 24301D 24302D

Page 44: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

b

@7

加熱時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

a

b

c

a

b

=

a

8292

1

4

62

64

65

48

46

40

3739

3836

43

45

32

32

32

4142

5655

49

50

44

3335

51

50

53

57

59

58

61

60

6362

66

16

15

14

13

13

19

72

4324

25

73

26

29

3

17

26

23

21

12

21

20

191817

b

a

7 5

FA300 W (D) Exploded View F Type FA-300-5W

F Type FA-300-10W

44

Page 45: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-300 W (D) Spare Parts List F Type FA-300-5W

F Type FA-300-10W

45

*Pressure lever complete set/ Code 26 for double heating type consists of numbers 1 , 2 , 4 - 8 , 12 , 21 , 23 , 26 , 29 , 51 , 64 , 65 .

Parts Code No. Parts name Sales unit

1 24304B Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24299 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

12 30511 Silicone rubber (white) 2 pcs/set

13 30031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 30210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 30200 Teflon sheet holder support (with screw, nut) 1 pc.

20 30005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

24 30192 Teflon sheet 2 pcs/set

25 30193 Teflon sheet roll bar 2 pcs/set

26 30191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

32 a,b 30033B Common frame (W/D) 1 pc.

33 39141B # Microswitch 1 pc.

35 39142 # Microswitch case 1 pc.

36 30530 Tramsformer mounting frame 1 pc.

Parts Code No. Parts name Sales unit

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 15 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 ----- Power switch 1 pc.

46 ----- Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24291 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 ----- Solenoid set 1 set

55 ----- Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

62 24341 Table switch plate 1 set

63 24345 Table switch plate spring 2 pcs/set

64 30215 Upper Teflon sheet holding plate (w/ screw, spring) 1 pc.

65 39497 Upper Teflon sheet holding bracket 2 pcs/set

66 24342 FA pedal holder (with nut) 1 pc.

Special Parts ListCode Parts Name FA-300-5D FA-300-10D

7Heating element (20pcs/set) 30246 34240

Heating element (10pcs/set) 59022 59024

12 Transformer - -

13 Transformer core cover 27350 32350

14 Transformer cover 30130 27130

15 Transformer fastening screw 30131 34131

16 Powre cord - -

26 Pressure lever complete set 24305D 24310D

Page 46: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA-450-10

加 熱 時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

FA-450-10

6

4

7 5

b

a

bc

a

=

a

2

21

9

3

45

48

4636

43

39

38

40

37

41

42

42

50 44

75

4955

56

30

29

24

72

19

23

2526

4433

35

51

50

53

59

57

61

58

60

1718 19

20

21

15

14

13

13

8

32

32

32

16

73

17

@7

b

a

FA-450 S Exploded View G TypeFA-450-5

G TypeFA-450-10

46

Page 47: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-450 S Spare Parts List G TypeFA-450-5

G TypeFA-450-10

47

*Pressure lever complete set/ Code 26 for single heating type consists of numbers 1 , 2 , 4 - 9 , 51 .

Parts Code No. Parts name Sales unit

1 24399 Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24599 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22067 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

9 3 Silicone rubber 2 pcs/set

13 27031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 27210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 27200 Teflon sheet holder support (with screw, nut) 1 pc.

20 27005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

24 27192 Teflon sheet 2 pcs/set

25 27193 Teflon sheet roll bar 2 pcs/set

26 27191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

30 421702B Terminal cover (with Screw) 2 pcs/set

32 a,b 30032B Common frame (S) 1 pc.

33 39141B # Microswitch 1 pc.

Parts Code No. Parts name Sales unit

35 39142 # Microswitch case 1 pc.

36 11 Tramsformer mounting frame 1 pc.

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 15 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 28 Power switch 1 pc.

46 17 Control unit 1 pc.

29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24591 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 19 Solenoid set 1 set

55 21 Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

75 53601 FEP outlet transformer 1 pc.

Special Parts ListCode Parts Name FA-450-5 FA-450-10

3 Silicone rubebr 27230B 27620B

7Heating element (20pcs/set) 27246 27610

Heating element (10pcs/set) 59038 59039

11 Tramsformer mounting frame 30530 -

12 Transformer - -

13 Transformer core cover 27350 27355

14 Transformer cover 30130 32130

15 Transformer fastening screw 30131 27132

16 Power cord - -

17 Control unit - -

19 Solenoid set - -

21 Cooling fan - -

26 Pressure lever complete set 24401D 24402D

28 Power switch - -

Page 48: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA-450-10W/D

FA-450-10W/D

加 熱 時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

6

4

7 5

b

b

a

b

c

a

b

=

a

8

12

29

2

32

32

32

45

3373

67

26

44

29

4636

37

38

41

43

40

42

3948

42

44

75

49

50

5556

57

50

53

51

59

58

61

60

29

19

23

72

24

2526

13

14

13

15

16

1918

17

20

21

73

17

1221

23

64

3

a

35

FA-450 W (D) Exploded View F typeFA-450-5W

F typeFA-450-10W

48

Page 49: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-450 W (D) Spare Parts List F typeFA-450-5W

F typeFA-450-10W

49

*Pressure lever complete set/ Code 26 for double heating type consists of numbers 1 , 2 , 4 - 8 , 12 , 21 , 23 , 26 , 29 , 51 , 64 , 65 .

Parts Code No. Parts name Sales unit

1 24400B Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24599 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

12 27521 Silicone rubber (white) 2 pcs/set

13 27031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 30181 Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 27210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 27200 Teflon sheet holder support (with screw, nut) 1 pc.

20 27005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

24 27192 Teflon sheet 2 pcs/set

25 27193 Teflon sheet roll bar 2 pcs/set

26 27191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

32 a,b,c 30033B Common frame (W/D) 1 pc.

33 39141B # Microswitch 1 pc.

Parts Code No. Parts name Sales unit

35 39142 # Microswitch case 1 pc.

36 11 Tramsformer mounting frame 1 pc.

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 32132 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 28 Power switch 1 pc.

46 17 Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24591 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 19 Solenoid set 1 set

55 21 Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

64 27215 Upper Teflon sheet holding plate (w/ screw, spring) 1 pc.

67 18115 Plastic nut (white) 5mm 5 pcs/set

75 53601 FEP outlet transformer 1 pc.

Special Parts ListCode Parts Name FA-450-5D FA-450-10D

7Heating element (20pcs/set) 27246 27610

Heating element (10pcs/set) 59038 59039

11 Tramsformer mounting frame 30530 -

12 Transformer - -

13 Transformer core cover 32350 27355

14 Transformer cover 27130 32130

16 Power cord - -

17 Control unit - -

19 Solenoid set - -

21 Cooling fan - -

26 Pressure lever complete set 24405D 24410D

28 Power switch - -

Page 50: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

FA-600-10

FA-600-10

加 熱 時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

6

4

7 5

b

c

b

a

a

ba

3

1921

2023

1724

25

26

73

17

3029

8

72

45

68

68

68

15

50

4142

43

3335

44

42

40

39

3836

37

48

46

75

2930

13

14

4955

56

44

51

50

5361

58

59

60

57

1918

17

92

21

FA-600 S Exploded View G TypeFA-600-5

G TypeFA-600-10

G TypeFA-600-2

50

Page 51: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-600 S Spare Parts List G TypeFA-600-5

G TypeFA-600-10

G TypeFA-600-2

51

*Pressure lever complete set/ Code 26 for single heating type consists of numbers 1 , 2 , 4 - 10 , 51 .

Parts Code No. Parts name Sales unit

1 24600 Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24599 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure adjustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

9 3 Silicone rubber 2 pcs/set

13 32030B Seal frame (with Teflon sheet holding screw) 1 pc.

14 24680B Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 32210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 32200 Teflon sheet holder support (with screw, nut) 1 pc.

20 32005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

24 32192 Teflon sheet 2 pcs/set

25 32193 Teflon sheet roll bar 2 pcs/set

26 32191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

30 421702B Terminal cover (with Screw) 2 pcs/set

33 39141B # Microswitch 1 pc.

Parts Code No. Parts name Sales unit

35 39142 # Microswitch case 1 pc.

36 11 Tramsformer mounting frame 1 pc.

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 15 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 28 Power switch 1 pc.

46 17 Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24591 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 19 Solenoid set 1 set

55 21 Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

68 a,b,c 24675B Teflon sheet center holder (w/ nut, screw, s washer, rubber) 1 set

75 53601 FEP outlet transformer 1 pc.

Special Parts List Code Parts Name FA-600-2 FA-600-5 FA-600-10

3 Silicone rubebr 32230B 32230B 32231B

7Heating element (20pcs/set) 32247 32246 38246

Heating element (10pcs/set) 59043 59045 59046

11 Tramsformer mounting frame 30530 30530 -

12 Transformer - - -

13 Transformer core cover 32351 32350 32355

14 Transformer cover 30130 27130 32130

15 Transformer fastening screw 32131 32132 32133

16 Power cord - - -

17 Control unit - - -

19 Solenoid set - - -

21 Cooling fan - - -

26 Pressure lever complete set 24601D 24601D 24602D

28 Power switch - - -

Page 52: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

b

a

c

b

a

a

@7

b

加熱時 間冷 却 時 間運 転 間 隔 加熱中冷

却中連続運転中連続運転ON/OFF

モード切 替

中止

FA-600-10W/D

FA-600-10W/D

29

1

2

8

2

6773

26

3

721921

2023

45

73

68

681516

5014

4955

56 44

3533

75

44

57

53

50

51

61

60

1918

48

46

37

3638

39

40

43

1341

29

42

42

17

6817

172524

26

64

23

21

12

58

59

6

4

7 5

FA-600 W (D) Exploded View F TypeFA-600-5W

F TypeFA-600-10W

52

Page 53: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

●Specify the part number and product name when ordering.

●Specify the part name if there is no part number. ● The parts with # mark are common parts with FA series.

FA-600 W (D) Spare Parts List F TypeFA-600-5W

F TypeFA-600-10W

53

*Pressure lever complete set/ Code 26 for double heating type consists of numbers 1 , 2 , 4 - 8 , 12 , 21 , 23 , 26 , 29 , 51 , 64 , 67 , 73 .

Parts Code No. Parts name Sales unit

1 24608B Pressure lever 1 pc.

2 a,b 30020 # Lever fastening bolt (w/ nut, whashers) 2 pcs/set

3 24599 Large pressure spring 1 pc.

4 24010 # Pressure adjusting nut with label 1 pc.

5 24030C # Small lever (w/ screw, spring, switch pin) 1 pc.

6 24071B # Switch pin set (w/ nut, s washer) 1 set

7 22007 # Pressure a djustment nut mounting screw 1 pc.

8 22080 # Pressure rubber 1 pc.

12 32235 Silicone rubber (white) 2 pcs/set

13 32031B Seal frame (with Teflon sheet holding screw) 1 pc.

14 24680B Teflon sheet holding screw (with lead wire hoder) 2 pcs/set

15 24040B # Thermistor 1 pc.

16 24045 # Thermistor metal fitting (with screw) 1 pc.

17 30171 # Plastic nut (black) 6mm 5 pcs/set

18 32210 Teflon sheet holding plate (lower) 1 pc.

19 a,b 32200 Teflon sheet holder support (with screw, nut) 1 pc.

20 32005 Sarcon sheet 2 pcs/set

21 39434 # Glass tape 25mm width x 5M roll 1 roll

39435 # Glass tape 25mm width x 10M roll 1 roll

23 7 Heating element (L-shaped terminal) 20 pcs./set

24 32192 Teflon sheet 2 pcs/set

25 32193 Teflon sheet roll bar 2 pcs/set

26 32191 Teflon sheet with roll bar 2 pcs/set

73 18018 # Teflon roll bar fastening plate 2 pcs/set

72 30190 # Teflon cushioning rubber 1 pc.

29 421700B # H-type electrode 2 pcs/set

33 39141B # Microswitch 1 pc.

Parts Code No. Parts name Sales unit

35 39142 # Microswitch case 1 pc.

36 11 Tramsformer mounting frame 1 pc.

37 12 Transformer (with core cover) 1 pc.

38 13 Transformer core cover 1 pc.

39 14 Transformer cover 1 pc.

40 15 Transformer fastening screw (with s-washer) 4 pcs/set

41 30275 # Seal plate (with screw) 1 pc.

42 16 Power cord (with rubber bush) 1 pc.

43 24005 # Main frame mounting bolt (with s-washer, nut) 2 pcs/set

44 39495B # Bottom cover (with outlet) 1 pc.

45 28 Power switch 1 pc.

46 17 Control unit 1 pc.

- 29115 # Fuse 1 pc.

48 30150B # Control unit mounting screw 4 pcs/set

49 24591 Body frame 1 pc.

50 24080 # Air damper (w/ holding plate) 1 pc.

51 24075B # Slide shaft (with lifter) 1 pc.

53 19 Solenoid set 1 set

55 21 Cooling fan 1 pc.

56 24091 # Cooling fan guard (w/ screw) 1 pc.

57 24100 # Body frame air switch (w/ elbow joint) 1 pc.

58 24002 # Bottom plate (w/ sponge) 1 pc.

59 24068 # Rubber feet (w/ screw) 4 pcs/set

60 24170 # Air pedal (with horse) 1 pc.

61 24171 # Air pedal horse only 1 pc.

64 32215 Upper Teflon sheet holding plate (w/ screw, spring) 1 pc.

67 18115 Plastic nut (white) 5mm 5 pcs/set

68 a,b,c 24675B Teflon sheet center holder (w/ nut, screw, s washer, rubber) 1 set

75 53601 FEP outlet transformer 1 pc.

Special Parts ListCode Parts Name FA-600-5D FA-600-10D

7Heating element (20pcs/set) 32246 38246

Heating element (10pcs/set) 59045 59046

11 Tramsformer mounting frame 30530 -

12 Transformer - -

13 Transformer core cover 32350 32355

14 Transformer cover 27130 32130

15 Transformer fastening screw 32132 32133

16 Power cord - -

17 Control unit - -

19 Solenoid set - -

21 Cooling fan - -

26 Pressure lever complete set 24605D 24606D

28 Power switch - -

Page 54: Automatic Impulse Sealer FA Series - fujiimpulse-vn.comfujiimpulse-vn.com/vi/UserGuide/Máy ép vận hành bán tự động... · The impulse sealer is a machine which sends strong

Y6598 JAN 2011 2nd EditionFA Series Operating Instructions Ver2.01E