39
baryon your sustainable business solution

Baryon HP_Company Profile_Brief_v1.4_A1

Embed Size (px)

Citation preview

bary

on

your sustainable business solution

bary

on

po

nd

pas

siv

e c

oo

lin

gg

rou

nd

co

oli

ng

evap

ora

tive

co

oli

ng

bary

on

BARYON was born from the high demands for businesses with sustainable

solutions, hence design with sustainable approach is a must, not only

from the climate change point of view but also from the context of

resource efficiency. Facing an emerging market in ASIA, BARYON gives

its years of experiences as well as multinational talents’ background.

The market often requires a custom, tailor-made approach to meet their

specific requirements, one fits all design, less complicated design

process by avoiding multiple consultant for one project and so on.

BARYON provide a one-stop-shop solution of engineering and procurement in

sustainable manner as a way of doing business. With a complete

package of experts in the area of electrochemistry, bio-chemical,

waste treatment, IT system, automation and control system, energy

management system, renewable energy, computational fluid

dynamic, energy efficiency, green building to green manufacturing;

the company would bring all clients into a different dimension, where

inefficiency of energy, waste, water and production process will be

history.

With experts who have over 15-25 years of working experiences under their

belts, with global experiences, PhD degrees, and prior cooperation with

reputable companies and institutions, the capabilities of experts at

BARYON are proven.

BARYON have the best team ready to work the way clients want. Our team

consists of 100% highly trained personnel who can do both inbound and

outbound, all of our personnel are experienced driving forces and most of

them have been working in research and development of sustainable

engineering and construction environment for more than 15-25 years.

BARYON also very strong in the area of energy, water, and environmental

management, as well as quality and safety management. We help our

customers to improve their system reliability, availability, maintainability,

and safety performances. We have a good Human Resource

Management to evaluate new staff that are trained, to make sure that we

have the best agents on the floor. Our staff were chosen by the HRM

because of their experience and achievement of being the top most in the

campaigns they worked on in the past. We do not stop training after the

campaign start, we continue monthly so our personnel stay fresh and

excited and on top of their game.

BARYON do have a team of around 8 (eight) Ph.D.’s and many professionals

of different expertise with capacity of expansion, depending on fields of

operation.

NUKI AGYA UTAMA, PhD

PRESIDENT DIRECTOR

DR. ROSSI SETIADJI

OPERATIONAL DIRECTOR

BARYON

BARYON

bary

onrenewable energy

cooling system

contractors and interior

waste to energysolar thermal

Integrated photovoltaic

Green - Lean - Smart

bary

on

Dr. HANDRI SANTOSO

SOLUTION SPECIALIST IN AUTOMATION SYSTEM

DESIGN AND ENGINEERING

PhD information science and control engineering

Mastering in sensor system, automation and instrumentation

The era of modernization reflected inthe design concept for factories andbuilding designed by BARYON. Thesmart thermal sensor for fireprevention, automatic guided vehiclewith line follower for an easy use andless human involvement in thefactory will definitely helping ourclient to have their cutting edgetechnology in their own backyard

bary

on

Design with simulations process creatinga perfection, less cost and less wasteThermal analysis and ComputationalFluid Dynamic is a default analysis forour design

DR. DENA HENDRIANA

COMPUTATIONAL FLUID DYNAMIC expert

PhD in Mechanical Engineering from MIT

Thermal analysis and aerodynamics analysis of vehicles (FORD motor).

mastering in computational fluid dynamic for industrial, automotive and renewable energy

bary

on

UPVC

NUKI AGYA UTAMA, PhD

EXPERT IN GREEN BUILDING DESIGN,

THERMAL ANALYSIS AND MATERIAL

DESIGN

PhD in Energy and Environmental Technology

Post Doctoral Energy Science, Kyoto

University

Mastering in green and passive design for

building and manufacture

It is important to analysed priorconstructing any building, the analysisincluding facade thermal resistant, roomcooling load, human comfort as well asits cost analysis.

therm

al co

mfo

rt s

imu

lati

on

bary

on

Experiences:University of Ha’il SAUDI ARABIA, MedicalSchool LaboratoryUniversity of INDONESIA, JAKARTA,INDONESIA. Medical Education and ResearchCenter (MERC-FK UI)

DR. KHOLIS A. AUDAH

LIFE SCIENCES AND LABORATORY DESIGN expert

PhD in Biochemistry from Auburn University, USA, mastering in genetic and protein

engineering and Postdoctoral in Infectious Diseases from Yale University School of

Medicine, USAin

teg

rate

d g

reen

lab

ora

tory

Current laboratory design requires not onlysafety and quality, but also requireengineering touch when the energyconsumption is minimum, system aremostly automatic with users friendlydesign. BARYON’s green and lean conceptfor the future laboratory design will giveclients a brand new perspective for thenew age of laboratory design andprocurement.

Expertises:Bio-chemist and bio medical scientist [antiaging-anti oxidant] from natural products

bary

on

With the tagline of zero run offconcept, our design ofperfection will optimally reducewater losses thereforereducing client expensesRain harvesting concept and100% reusable grey waterBARYON green and lean designwill give non waste concept forits client.

ROSSI SETIADJI, PhD

WATER AND WASTE expert

Mastering in IW, STP and WWTP design.

Process Design for pharmaceutical, cosmetics , food and beverage

industry

bary

on

Smart class

Sm

art

lab

ora

tory

Smart hospital

Smart home

Dr. AKHMAD UNGGUL PRIANTORO

SMART SYSTEM expert

PhD in Information Systems from Nara Institute of Science and Technology

(Japan)

IT Infrastructure design and management (IIU Malaysia)

mastering in IT infrastructure design for enterprise network

In the efficiency terminology,automation and smart IT are theimportant factors to fast forwardthe process. However thesesystem can be a backfiring whenthe concept avoiding an overallaspects. BARYON’s Green smartIT system will be a break throughsolution for the future buildingdesign

bary

on

Dr. RUDI IRAWAN

SENSING AND ENERGY SOLUTION Expert

PhD in Physics and Electronics Engineering (Australia)

Mastering in sensor technology, renewable energy, energy efficiency and energy

audit.

Energy efficiency is one of theimportant key factor to saveenergy intensive in human modernliving, the combination withrenewable energy will be theperfect match to reduce globalwarming effect as well as releasinghuman dependency with fossilfuel.

bary

on

FERDINAND ARIESTA, ST,

PROJECT MANAGEMENT Expert

Quantity surveyor and Project

Management certificate and Scheduler

expert certificate

LEAN construction has beenknown worldwide as one ofthe system which help bothowner and main contractor toreduce its cost. Combined withthe personal expertise on QSand mastering in schedulerswill bring BARYON leading inthe business.

HAMPTONS PARK, PONDOK INDAH

bary

on

EKI YOGASWARA, ST

SENIOR ARCHITECT designing various high-rise building and green factory

GREEN DESIGN architect willgive a natural and moderntouch to the factory buildingswith an optimum natural windventilation as well as daylighting system.

EXPERT

DIRECTOR OPERATIONAL

ROSSI SETIADJI, PhD

LE

GA

L a

nd H

RD

(part

ner)

AD

YO

LA

BD

O K

UM

OL

O,

SH

, M

.Kn

AR

CH

ITE

CT

UR

E n

ST

RU

CT

UR

ED

I S

ISW

AN

TO

, S

T

EK

I Y

OG

AS

WA

RA

, S

T

RU

DIY

AN

TO

FA

HR

UR

RO

ZY

INT

ER

IOR

DE

AS

Y,

ST

, M

T

HE

NY

NO

OR

HA

YA

TI, S

T,

MT

PR

OC

UR

EM

EN

T

MO

H.

AR

DH

AN

A A

ZW

IR,

SS

CO

NS

TR

UC

TIO

N

Ir.

SA

SO

NO

TA

NT

RO

GA

RJIT

O W

AH

YU

DI, S

T

Ir.

KA

RT

IKO

BU

DI U

TO

MO

,ST

PR

OD

UC

T (

part

ner)

RO

MD

HO

NI S

AP

UT

RA

, S

T

AD

MIN

IST

RA

TIO

N

KA

RIN

A R

AM

AD

IYA

NT

I

MA

RIA

RO

HM

AH

HID

AY

AN

TI

RE

SE

AR

CH

and D

EV

ELO

PM

EN

T

JO

AN

RO

SS

I

AK

HM

AD

FLUID DYNAMIC EXPERT

Dr. DENA HENDRIYANA

BIO ENGINEERING EXPERT

KHOLIS AUDAH, PhD

SYSTEM CONTROL EXPERT

Dr. HANDRI SANTOSO

WASTE SOLID n WATER EXPERT

ANANTO WIMBAJI, ST

DIR. ENERGY

DR. RUDI IRAWAN

DIR. SMART system

Dr. UNGGUL PRIYANTORO

PROJECT DIRECTOR

FERDINAND ARIESTA, ST

PRESIDENT DIRECTOR

NUKI AGYA UTAMA, PhD

CONTRACTUAL PROJECT BASED STAFF

bary

on

bary

on

your sustainable business solution

Client : PT. SCI

Location : Salatiga, Central Java

Area : 22 hectares

bary

on

GREEN and LEAN design

Master plan

Architecture design

Project monitoring

Infrastructure concept

Structural design

Factory [6000 workers]

Office [200 staff]

Dormitory [48 rooms]

bary

on

Client : PT. CEMINDOI

Location : Lebak, Banten

Area :

bary

on

GREEN and LEAN design

General Construction

Structural design

MEP design

CONTAINER design

Workshop [60 workers]

Office [20 staff]

bary

on

GREEN interior design and built

Interior concept and 3D

Detail drawing

Cooling simulation

Heat resistant walls

Automatic censor lamp

Client : PT. KMK global sports

Location : Tangerang, Banten

Area : 1700 m2

Workshop [100

workers]

Office [40 staff]

bary

on

bary

on

Factory [±600 staff]SIMMULATION

Cooling system

Computational fluid Dynamics

Thermal analysis

Client : PT. KMK global sports

Building : Assembly building

Location : Tangerang, Banten

Area : 3000 m2

bary

on

PT. POU YEN [6000m2], Cianjur, West Java

Office [200-400 staff]

GREEN design conceptMaster plan

Rainwater harvesting

Day lighting

bary

on

bary

on

PT. NIKOMAS [6000m2], Cikande, West Java

Office [200-400 staff]

RENOVATION with SIMULATION

Architecture design

Wind and thermal simulation

bary

on

FLUID DYNAMIC

and THERMAL

ANALYSIS

bary

on

Esa Unggul University, Jakarta

High-rise building [n/a]

Mini hospital [10 staff]

Basement and parking lot [2 level]

GREEN building design concept

Master plan

Architectural concept

Cooling system

bary

on

SOLAR GEOMETRIC,

GREEN MATERIAL

and RENEWABLE

ENERGY

bary

on

Client : PT. KMK global sports

Building : Recycle Material Consolidation Center [RMCC]

Location : Tangerang, Banten

Area : 700 m2

GREEN building design concept

Green Storage design

Architectural concept

Green material design

bary

on

Client : PT. KMK global sports

Building : Kitchen and Canteen

Location : Tangerang, Banten

Area : 700 m2 and 4800 m2

Users : 10,000 people

GREEN building design concept

Green Storage design

Architectural concept

Green material design

bary

on

Confidential, Cimanggis, West Java

Factory [200 staff]

Office [10 staff]

FACTORY design and built

Lay out design

Cooling system

bary

on

LABIRYNT

CHAMBER bary

on

bary

on

Machin

e 1

Machin

e 2

Water from ground tank

Humid warm working air released to atmosphere

Evaporator

Heat

Exchanger

Ground TANK

Warm supply air from outdoor

Warm working air from outdoor

Cooled supply air sent to thebuilding/room. Its absolutehumidity is the same as thehumidity of outdoor air

In the evaporator, theworking air vaporizescool water supplied byground tank. This processlowers working airtemperature, butincreases its humidity.In the Heat Exchanger,the working air willabsorb heat in the supplyair causing thetemperature of supply airlowers down.

Warm outdoor air enters the evaporative coolingmachine through two inlet channels. One directlygoes to the Heat Exchanger, and then enters thebuilding/room as cooled fresh supply air. Theother as working air goes to the evaporator,passes through the Heat Exchanger, and then isreleased to the atmosphere or ground watertank.

Part of supply air is also returned to the evaporator to help better efficiency of cooling system

In the evaporator, the working air vaporize coolwater which is supplied by ground tank/reservoir.This process lowers working air temperature, butincreases its humidity

In the Heat Exchanger, the working air will absorb heat in the supply air which causes the temperature of supply air lowers down

Through these whole processes, the supply air is lower temperature than the outdoor air, but the absolute air humidity does not increase.

bary

on

Ground water tank

machine

Cool air to building

Humid air to ground water tank

Warm air to indirect

evaporative cooler

bary

on

bary

on

How many degrees that theair temperature will reducedepend on the air humidity.For an example, if airtemperature is 30 C and airrelative humidity is 60%, theoutput air temperature islikely 23 C.

Ground cooling-IndirectEvaporative air cooler isenable to lower ambientair temperature, and keepthe absolute humidity ofoutput air is the same asambient air humidity.

75% - 80% energy saving as compared to AC

Less maintenance

no chemical

no refrigerant

no green-house gas emission

no air pollutant emission CASE. SALATIGA

HUMIDITY ± 60%

TEMPERATURE ± 30 °C

bary

on

bary

on

INDONESIA

bary

on

BARYON hasta persadae. [email protected]

a. ruko jalur sutera 16a no 15, alam Sutera, tangerang

w. www.baryon-hp.com

bary

on