Beams Stephen Krone, DSc, PE University of Toledo

Beams Krone.ppt

Embed Size (px)

Citation preview

Page 1: Beams Krone.ppt

Beams

Stephen Krone, DSc, PEUniversity of Toledo

Page 2: Beams Krone.ppt

Shear and Moment

A beam is a structural member subjected to transverse loads and negligible axial loads.

Page 3: Beams Krone.ppt

Internal Shear Causes Moment

These internal shear forces and bending moments cause longitudinal axial stresses and shear stresses in the cross-section.

Page 4: Beams Krone.ppt

Increasing Loads

Maximum bending moment is reached at extreme fibers first, where the stress reaches the yield stress limit.

Page 5: Beams Krone.ppt

The Moment - Curvature (M-f) response With Increasing Moment

Page 6: Beams Krone.ppt

My is the yield and Mp is the plastic moment capacity of the cross-section. The ratio Mp to My is the shape factor f. For a rectangular section, f is equal to 1.5. For a wide-flange section, f is equal to 1.1.

Page 7: Beams Krone.ppt

Developing the Plastic Moment

Page 8: Beams Krone.ppt

LRFD Raised the ASD Limit State

Page 9: Beams Krone.ppt

Columns’ Slenderness Ratio Controls the Critical Buckling Stress

Page 10: Beams Krone.ppt

Lateral Torsional Buckling Behavior

Compression flange begins to buckle out of plane.Bracing on the compression flange makes it more difficult to fail.

Page 11: Beams Krone.ppt

Methods of Bracing Compression Flange

Page 12: Beams Krone.ppt

Beam and Column Similarities• The design of the beam is usually

based on the compression flange.

• The braced length of support of the compression flange, Lb, usually determines the type of failure.

• There are three zones of failure: plastic, inelastic buckling, and elastic buckling.

• Each failure zone has its own set of equations.

Page 13: Beams Krone.ppt

Lateral Torsional Buckling: Lb Lp

AISC F2-1 AISC F2-

2

Mn = Fcr Sx <= Mp

AISC F2-3

AISC F2-5Lp = 1.76 ry yFE /

Lr AISC F2-6 AISC 16.1-48

Plastic

Inelastic Buckling

Elastic Buckling

Page 14: Beams Krone.ppt

Plastic Buckling• Most beams fall in the plastic zone. • AISC Table 3-10

• Fully braced reaches full Mp. This is closely spaced lateral bracing, where Lb < Lp

AISC F2-1 AISC F2-2

Mn = Fcr Sx <= MpAISC F2-3

Page 15: Beams Krone.ppt

Plastic centroid. A1

A2

y

y

yA1

yA2

y1

y2

22

11

21y

21

2y1y

Aofcentroidy

Aofcentroidy,Where

)yy(2

AM

2/AAA

0AAF

Plastic centroid. A1

A2

y

y

yA1

yA2

y1

y2

22

11

21y

21

2y1y

Aofcentroidy

Aofcentroidy,Where

)yy(2

AM

2/AAA

0AAF

Plastic Section Modulus

Page 16: Beams Krone.ppt

Mp, Plastic Moment and Plastic Section Modulus

Page 17: Beams Krone.ppt

W Shapes – Braced => Mp

Page 18: Beams Krone.ppt

Mp, Plastic Moment

Concrete floor slab provides lateral bracing.Lb= 0.

Page 19: Beams Krone.ppt

Beam Example: Compact & Braced

Design a simply supported beam subjected to uniformly distributed dead load of 450 lbs/ft. and a uniformly distributed live load of 550 lbs/ft. The dead load does not include the self-weight of the beam.

Step I. Calculate the factored design loads (without self-weight).

• wU = 1.2 wD + 1.6 wL = 1.42 kips / ft.

• MU = wuL2/8 = 1.42 x 302/8 = 159.75 kip-ft.

Page 20: Beams Krone.ppt

Beam Example (Cont.)Step II. Select the lightest section

from the AISC Manual design tables.

• From the AISC manual, select W16 x 26 made from 50 ksi steel with fbMp = 166.0 kip-ft.

Step III. Add self-weight of designed section and check design

• wsw = 26 lbs/ft• Therefore, wD = 476 lbs/ft = 0.476

lbs/ft.• wu = 1.2 x 0.476 + 1.6 x 0.55 = 1.4512

kips/ft.• Therefore, Mu = 1.4512 x 302 / 8 =

163.26 kip-ft. < fbMp of W16 x 26.• OK!

Page 21: Beams Krone.ppt

Step IV. Check deflection at service loads.

• w = 0.45 + 0.026 + 0.55 kips/ft. = 1.026 kips/ft.

• D = 5 w L4 / (384 E Ix) = 5 x(1.026/12) x (30 x 12)4/(384 x

29000 x 301) • D = 2.142 in. > L/360

Step V. Redesign with service-load deflection as design criteria

• L /360 = 1.0 in. > 5 w L4/(384 E Ix)

• Therefore, Ix > 644.8 in4

Beam Example (Cont.)

Page 22: Beams Krone.ppt

Example (Cont.)

• Select the section from the moment of inertia tables in the AISC Table 3-3. (p. 3-21) Ix > 644.8 in4

• Select W21 x 44.

• W21 x 44 with Ix = 843 in4 and fbMp = 358 kip-ft. (50 ksi steel).

• Deflection at service load D = 0.765 in. < L/360 -

OK!

Page 23: Beams Krone.ppt

Step VI. Check shear for W16 x 26 .

wu = 1.2 wD + 1.6 wL = 1.42 kips / ft.V = wl/2 = 1.42(30)/2 = 21.3 kips

Vn = 0.6FyAwCv

= 0.6 (50ksi)(0.25x15.7)(1.0)= 118 kips > 21.3 kips

Vn can be compared with Z Table (3-2) of

fvVnx = 106.0 kips > 21.3 kips

Beam Example (Cont.)

Page 24: Beams Krone.ppt

Non-plastic Failure

The development of a plastic stress distribution over the cross-section can be hindered by two different length effects:

(1)Local buckling of the individual plates (flanges and webs) of the cross-section fail before they develop the compressive yield stress sy.

(2) Lateral-torsional buckling of the unsupported length of the beam / member fail before the cross-section develops the plastic moment Mp.

Page 25: Beams Krone.ppt

Lateral-Torsional Buckling• Lb of a beam-member

can undergo lateral-torsional buckling due to the applied flexural loading (bending moment).

• Lateral-torsional buckling is similar to the flexural buckling or flexural-torsional buckling of a column subjected to axial loading.

• There is one very important difference. For a column, the axial load causing buckling remains constant along the length. But, for a beam, usually the lateral-torsional buckling causing bending moment varies along the unbraced length.

Page 26: Beams Krone.ppt

LTB: Lateral-Torsional Buckling• bMn is a function of:

– Beam section properties – (Zx, ry, x1, x2, Sx, G, J, A, Cw, Iy)

– Unbraced length, Lb – Lb = distance between points

which are either braced against lateral displacement of compression flange or braced against twist of the cross section

– Lp : Limiting Lb for full plastic bending capacity

– Lr : Limiting Lb for inelastic LTB

• E : Modulus of elasticity, ksi

• Cb: Bending coefficient based on moment gradient.

Page 27: Beams Krone.ppt

Lateral Torsional Buckling: Lp Lb Lr

• If the laterally unbraced length Lb is less than or equal to a plastic length Lp then lateral torsional buckling is not a problem and the beam will develop its plastic strength Mp.

• - for I members & Channels (See Pg. 16.1-48, F2-5)

• If Lb is greater than Lp then lateral torsional buckling will occur and the moment capacity of the beam is reduced below the plastic strength Mp.

Lp = 1.76 ry yFE /

Page 28: Beams Krone.ppt

Lateral Torsional Buckling: Lp Lb Lr

AISC F2-1 AISC F2-

2

Mn = Fcr Sx <= Mp

AISC F2-3

AISC F2-5Lp = 1.76 ry yFE /

Lr AISC F2-6 AISC 16.1-48

Page 29: Beams Krone.ppt

Lateral Torsional Buckling: Lp Lb Lr

• When Lp Lb Lr, then the lateral-torsional buckling Mn is given by:

Mn= Cb[Mp – (Mp -0.7Fy Sx )(Lb- Lp / Lr–Lp)]

• Linear interpolation between (Lp, Mp) and (Lr, Mr)

• AISC Table 3-2 - Lp, Lr, Mp, MrMp

Mr

Lp Lb Lr

Page 30: Beams Krone.ppt

• As the spacing of lateral bracing increases but not all compression fibers will reach Fy.

• This is referred to as inelastic buckling.

• Easier to use BF: – Mn= Mp – (BF )(Lb- Lp)

• Lr is the point where the transition is to elastic buckling.

Lateral Torsional Buckling: Lp Lb Lr

Page 31: Beams Krone.ppt

Lateral Torsional Buckling: Lb > Lr

AISC F2-1

AISC F2-2

AISC F2-3

• Elastic Buckling

• The buckling moment becomes smaller and smaller as the unbraced length increases.

• AISC p. 16.1-47

Page 32: Beams Krone.ppt

Lateral Torsional Buckling: Lb > Lr

AISC F2-1 AISC F2-

2

Mn = Fcr Sx <= Mp

AISC F2-3

AISC F2-5Lp = 1.76 ry yFE /

Lr AISC F2-6 AISC 16.1-48

Plastic

Inelastic Buckling

Elastic Buckling

Page 33: Beams Krone.ppt

Compact, Non-Compact, and Slender

• Slender sections cannot develop Mp due to elastic local buckling. Non-compact sections can develop My but not Mp before local buckling occurs.

• Only compact sections can develop the plastic moment Mp.

• Applies to major and minor axis bending

Page 34: Beams Krone.ppt

Local Buckling of Flange Due to Compressive Stress• Equations for local

buckling of steel plates have limiting slenderness ratios for the individual plate elements of the cross-sections.

• AISC B4 (page 16.14), Table B4.1 (16.1-13) and Page 16.1-223

• Steel sections are classified as compact, non-compact, or slender depending upon the slenderness (l) ratio of the individual plates of the cross-section.

M

M

M

M

Page 35: Beams Krone.ppt

Local Buckling

Page 36: Beams Krone.ppt

Limit States for Local BucklingTable B4.1 (p 16.1-16)

Page 37: Beams Krone.ppt

Limit States for Local BucklingTable B4.1 (p 16.1-16)

Page 38: Beams Krone.ppt

Strength Limit State for Local Buckling

• = Slenderness parameter; must be calculated for flange and web buckling (actually no web slender for W, M, C)

• p= limiting slenderness parameter for compact element

• r = limiting slenderness parameter for non-compact element

• p : Section capable of developing fully plastic stress distribution

Page 39: Beams Krone.ppt

Strength Limit State for Local Buckling

• p r : Section capable of developing yield stress before local buckling occurs; will buckle before fully plastic stress distribution can be achieved.

• r : Slender compression elements; will buckle elastically before yield stress is achieved.

Page 40: Beams Krone.ppt

Compact, Non Compact, or Slender• For inelastic buckling because of

unbraced length:Mn= Mp – (Mp -0.7Fy Sx )(Lb- Lp / Lr–Lp)]

• For Flange Local Buckling because flange in not compact:

Mn= Mp – (Mp -0.7Fy Sx )( - p / r - p)

AISC F2-2

AISC F3-1

Page 41: Beams Krone.ppt

The Bending Coefficient, Cb

• Worse case scenario is for compression flange under constant uniform moment

• Moments usually vary over unbraced length, so AISC uses Cb

to modify for only segment that undergoes LTB under the highest moment.

• This factor is similar to the effective length K that we modified in column buckling. – (Old formula like G/G)– Cb =1.75 +

1.05(M1/M2)+0.3(M1/M2 )

Page 42: Beams Krone.ppt

• Cb can always be taken as 1.

Cb =12.5 Mmax/(2.5Mmax+3Ma +4Mb + 3Mc)

• Mmax = maximum value in braced section

• Ma = value at quarter point

• Mb = value at center point

• Mc = value at three quarter point

The Bending Coefficient, Cb

Page 43: Beams Krone.ppt

The AISC Specification says that:• Cb is a multiplier.

• Cb is always greater than 1.0 for non-uniform bending moment.

– Cb is equal to 1.0 for uniform bending moment.

– If you cannot calculate or figure out Cb, then it can be conservatively assumed as 1.0.

Page 44: Beams Krone.ppt

Moment Capacity versus Lb

(for non-uniform moment case)

Page 45: Beams Krone.ppt

• Bending Coefficient, Cb

• AISC Table 3-1

Page 46: Beams Krone.ppt

Example

• Design the beam shown below. The unfactored uniformly distributed live load is equal to 3 kips/ft. There is no dead load. Lateral support is provided at the end reactions.

Page 47: Beams Krone.ppt

Step I. Calculate the factored loads assuming a reasonable self-weight.

• Assume self-weight = wsw = 100 lbs/ft.

• Dead load = wD = 0 + 0.1 = 0.1 kips/ft.

• Live load = wL = 3.0 kips/ft.• Ultimate load =

– wu = 1.2wD + 1.6wL = 4.92 kips/ft.

• Factored ultimate moment = – Mu = wu L2/8 = 354.24 kip-ft.

Page 48: Beams Krone.ppt

Step II. Determine unsupported length Lb & Cb

• One unsupported span with Lb = 24 ft.

• Cb = 1.14 for the parabolic bending moment diagram, See values of Cb shown in Table 3-1.

Step III. Select a wide-flange shape• The moment capacity of the selected

section fb Mn > Mu (Note fb = 0.9)

• fbMn = moment capacity = Cb x (fbMn for the case with uniform moment) fbMn

• Table 3-10 in the AISC-LRFD manual shows plots of fbMn - Lb for the case of uniform bending moment (Cb =1.0)

Page 49: Beams Krone.ppt

Therefore, in order to select a section, calculate Mu/ Cb and use it with Lb to find the first section with a solid line.

• Mu/ Cb = 354.24/1.14 = 310.74 kip-ft.

• Select W16 x 67 (50 ksi steel) fbMn =357 kip-ft. for Lb = 24 ft. and Cb =1.0

• For the case with Cb = 1.14,

• fbMn = 1.14 x 357 = 406.7 kip-ft., which must be fbMn = 491 kip-ft. OK!

• Thus, W16 x 67 made from 50 ksi steel with moment capacity equal to 406.7 kip-ft. for an unsupported length of 24 ft. is the designed section.

Page 50: Beams Krone.ppt

Step IV. Check for local buckling. Also found in footnotes of sections.

• l = bf / 2tf = 7.7; lp = 0.38 (E/Fy)0.5 = 9.192

Therefore, l < lp - compact flange

• l = h/tw = 34.4; lp = 3.76 (E/Fy)0.5 = 90.5

Therefore, l < lp - compact web

Page 51: Beams Krone.ppt

Step V. Check shear. (W16 x 67 made from 50 ksi steel)

wu = 1.2wD + 1.6wL = 4.92 kips/ft.

V = wl/2 = 4.92(24)/2 = 59 kipsVn = 0.6FyAwCv

= 0.6 (50ksi)(0.395x16.3)(1.0)

= 193 kipsOK

Page 52: Beams Krone.ppt

Step VI. Check deflection. (W16 x 67 made from 50 ksi steel)

D = Wl3/384 EID = (4.92 klf x 24ft)(24 x 12) 3/384(29,000 ksi)

(954 in4)

D = 0.27inDallow = L /360 = 24 x 12/ 360 = 0.8

in.

OK

Page 53: Beams Krone.ppt

Summary LRFD Beam Design1. Determine the location and

magnitude of the loads and draw a load diagram.

2. Determine if the shape is compact by calculating slenderness parameter

p Full plastic moment, Mp

p r Mn= Mp – (Mp 0.7Fy Sx )( - p / r - p)

> r Mn= Fcr Sx

Page 54: Beams Krone.ppt

Summary LRFD Beam DesignCheck Shape: If the shape is non

compact because of the flange, (calculate slenderness parameter)

p Full plastic moment, Mp

p r Mn= Mp – (Mp 0.7Fy Sx )( - p / r - p)

> r Mn= Fcr Sx

Page 55: Beams Krone.ppt

Summary LRFD Beam Design 3. Find Moment - Lateral Torsional Buckling

AISC F2-1 AISC F2-

2

Mn = Fcr Sx <= Mp

AISC F2-3

AISC F2-5Lp = 1.76 ry yFE /

Lr AISC F2-6 AISC 16.1-48

Page 56: Beams Krone.ppt

Summary LRFD Beam Design4. Check shear in the web

AISC G2-3

AISC G2-1

AISC G2-3 and AISC G2-3

yFE /h/tw = 2.24

Most cases with W shapesfv = 1 and Cv = 1,

fv = 0.9

Page 57: Beams Krone.ppt

Summary LRFD Beam Design5. Check deflection.

Page 58: Beams Krone.ppt

Summary

• Local buckling is not an issue for most beams for A992 beams

• Effective bracing is provided at ends to restrain rotation about the longitudinal axis.

• Effective bracing reduces Lb and prevents twist of the cross section and/or lateral movement of the compression flange.

• Cb is important in economical design when plastic moment is not developed

Page 59: Beams Krone.ppt

Works Cited

• Segui, William T. 2007. Steel Design. 4th ed. Thompson Engineering.

• Steel Construction Manual, 13th ed. AISC, 2005.

• CE 405: Design of Steel Structures –Dr. A. Varma