NORTH PROJECT LOCATION 0 1X 1 A101 1 A101 1 A101 GRID HEAD / LINES DOOR TAG / NUMBER WALL TYPE TAG KEYNOTE TAG REVISION TAG A401 1 1 3 2 4 A601 ROOM TAG EXTERIOR ELEVATION INTERIOR ELEVATION DETAIL REFERENCE SECTION REFERENCE CALLOUT DESIGNATION ELEVATION NUMBER SHEET NUMBER ELEVATION NUMBER SHEET NUMBER DETAIL NUMBER SHEET NUMBER SECTION NUMBER SHEET NUMBER CALLOUT NUMBER SHEET NUMBER 10' - 0" SPOT ELEVATION 9' - 0" CEILING HEIGHT TAG COLOR TAG CMU - 1 SEE SHEET A702 1 101 ROOM NUMBER ROOM NAME 101A BN000 CEILING HEIGHT PER REFLECTED CEILING PLAN SHEET NO: SHEET DESCRIPTION: JOB NO: CLIENT: PROJECT NAME: DATE: DRAWN: CHECK: ARCHITECT: ENGINEER: 14471 CHAMBERS RD, SUITE 210 TUSTIN, CA 92780 (714) 508-1780 508-1790 FAX Rev. Date Description No. NOT FOR CONSTRUCTION westberg white architecture PDW STATE: ARCHITECT: CONSULTANT: C:\Users\emercado\Documents\c20030-Master_emercado.rvt 1/21/2021 3:47:26 PM G001 SHEET INDEX, SYMBOLS, ABBREVIATIONS, AND NOTES NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT Fullerton College JG EM 01/21/2021 20030 BLDG 1000 IMPROVEMENTS 321 E Chapman Ave Fullerton Ca. 92832 1830 W. ROMNEYA DRIVE, ANAHEIM, CA 92801 VICINITY MAP TYPICAL SYMBOLS CENTERLINE & AND @ AT OR ABOUT ' FOOT " INCH OR REPEAT # POUND OR NUMBER +/ - VERIFY IN FIELD A.B. ANCHOR BOLT A.C. ASPHALTIC CONCRETE ACC. ACCESSIBLE ADJ. ADJUSTABLE / ADJACENT A.F.F. ABOVE FINISH FLOOR AGGR. AGGREGATE ALUM. ALUMINUM ANOD. ANODIZED APPROX. APPROXIMATE ARCH. ARCHITECTURAL ASPH. ASPHALT BD. BOARD BITUM. BITUMINOUS BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING B.M. BENCHMARK BOT. BOTTOM B/S BOTH SIDES B.W. BOTH WAYS C.B. CATCH BASIN CEM. CEMENT CLR. CLEAR CONC. CONCRETE IN. INCH INCND. INCANDESCENT INV. INVERT JT. JOINT LB. POUND L.F. LINEAL FEET LLH. LONG LEG HORIZONTAL LLV. LONG LEG VERTICAL L.P. LOW POINT LT. LIGHT LT. WT. LIGHT WEIGHT MACH. MACHINE MAT. MATERIAL MAX. MAXIMUM M.B. MACHINE BOLT MDF MAIN DISTRIBUTION FRAME MED. MEDIUM MEMB. MEMBRANE MET. METAL MFR. MANUFACTURER MH. MANHOLE MIN. MINIMUM / MINUTE MISC. MISCELLANEOUS MPOE MAIN POINT OF ENTRY MTD. MOUNTED (N) NEW NAT. NATURAL NT. GR. NATURAL GRADE N.I.C. NOT IN CONTRACT NO. NUMBER R.O. ROUGH OPENING RWD. REDWOOD S. SOUTH / SPANDREL S.C. SOLID CORE SCHED. SCHEDULE SECT. SECTION SERV. SERVICE / SERVING S.F. SQUARE FOOT SHT. SHEET SIM. SIMILAR SL. SLIDING SPEC. SPECIFICATION SQ. SQUARE S.S. STAINLESS STEEL STA. STATION STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL SUSP. SUSPENDED SYM. SYMMETRICAL T.C. TOP OF CURB OR CONCRETE TEL. TELEPHONE TEMP. TEMPERED / TEMPORARY T&G TONGUE AND GROOVE THK. THICK TOIL. TOILET T.O.W. TOP OF WALL TYP. TYPICAL TRNSF. TRANSFORMER CONN. CONNECTION CONSTR. CONSTRUCTION CONT. CONTINUOUS CONTR. CONTRACTOR CSK. COUNTERSUNK DBL. DOUBLE DEPT. DEPARTMENT DET. DETAIL D.F. DRINKING FOUNTAIN DIA. DIAMETER DIAG. DIAGONAL DIM. DIMENSION DISP. DISPENSER / DISPOSAL DN. DOWN DR. DOOR D.S.P. DRY STANDPIPE DWG. DRAWING (E) EXISTING E. EAST / ENAMEL EA. EACH EE EACH END E.G. EXISTING GRADE E.J. EXPANSION JOINT EL. ELEVATION ELEC. ELECTRICAL ELEV. ELEVATOR / ELEVATION EMER. EMERGENCY ENCL. ENCLOSURE E.O.S. EDGE OF SLAB EQ. EQUAL EQPT. EQUIPMENT E.S. EACH SIDE E.W. EACH WAY EXIST. EXISTING EXP. EXPANSION EXPO. EXPOSED FLUOR. FLUORESCENT FNDN. FOUNDATION F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.S. FULL SIZE / FINISH SURFACE FT. FOOT OR FEET FTG. FOOTING FURR. FURRING FUT. FUTURE GA. GUAGE / GAGE GALV. GALVANIZED IRON GEN GENERAL G.I. GALVANIZED IRON GR. GRADE H.B. HOSE BIBB H.C. HOLLOW CORE HDWD. HARDWOOD HDWR. HARDWARE HGT. HEIGHT H.M. HOLLOW METAL HORIZ. HORIZONTAL H.P. HIGH POINT HR. HOUR I.B.C INTERNATIONAL BUILDING CODE I.D. INSIDE DIAMETER / DIMENSION IDF INTERMEDIATE DISTRUBUTION NOM. NOMINAL N.T.S. NOT TO SCALE O/ OVER O.A. OVERALL / OUTSIDE AIR OBS. OBSCURE O.C. ON CENTER O.D. OUTSIDE DIAMETER / DIMENSION ORN. ORNAMENTAL IRON PH PANIC HARDWARE P.I.V. PRESSURE INDICATOR VALVE PL. PLATE PLUMB. PLUMBING P.M. PRESSED METAL PNL. PANEL P/P PUSH - PULL PR. PAIR PREFAB. PREFABRICATED PT. POINT R. RISER / RADIUS RAD. RADIUS REC. RECESSED / RECIEVING RECPT. RECEPTACLE REF. REFERENCE REV. REVERSE REG. REGISTER / REGULAR REINF. REINFORCED REQ. REQUIRED RESIL. RESILIENT R.H. ROUND HEAD RM. ROOM U.L. UNDERWRITER'S LAB UNFIN. UNFINISHED U.N.O. UNLESS NOTED OTHERWISE VERT. VERTICAL VEST. VESTIBULE V.I.F. VERIFY IN FIELD W. WEST / WOMEN W/ WITH WD. WOOD W/O WITHOUT WP. WATERPROOF W.R. WATER RESISTANT W.S. WOOD SCREW WT. WEIGHT W.W.M. WOVEN WIRE MESH KEYNOTES SPECIFIC TO BUILDING WORK BE BUILDING EXISTING BD BUILDING DEMOLITION BN BUILDING NEW KEYNOTES SPECIFIC TO SITE WORK SE SITE EXISTING SD SITE DEMOLITION SN SITE NEW 04 - XXXXXX 30 - C1 XX - XX - 20 SCOPE OF WORK THIS PROJECT CONSISTS OF BUT NOT LIMITED TO: DEMOLITION: 1. PARTIAL DEMOLITION OF INTERIOR WALLS AND CEILINGS G001 SHEET INDEX, SYMBOLS, ABBREVIATIONS, AND NOTES G002 OVERALL SITE PLAN (7 Sheets) ARCHITECTURAL BLDG 1000 IMPROVEMENTS North Orange County Community College District A001 ENLARGED PARTIAL SITE PLAN ABBREVIATIONS SHEET INDEX STATEMENT OF GENERAL CONFORMANCE PRINT NAME I FIND THAT: ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET THIS DRAWING OR PAGE IS/ARE IN GENERAL CONFORMANCE WITH THE PROJECT DESIGN, AND LICENSE NUMBER IS/ARE IN GENERAL CONFORMANCE WITH THE PROJECT DESIGN INTENT, AND SIGNATURE DATE C11045 ARCHITECT OR ENGINEER DESIGNATED TO BE IN GENERAL RESPONSIBLE CHARGE ARCHITECT OR ENGINEER DELEGATED RESPONSIBILITY FOR THIS PORTION OF THE WORK LICENSE NUMBER EXPIRATION DATE PRINT NAME EXPIRATION DATE Paul D. Westberg SEPTEMBER, 2019 HAS/HAVE BEEN COORDINATED WITH THE PROJECT PLANS AND SPECIFICATIONS. HAS/HAVE BEEN COORDINATED WITH THE PROJECT PLANS AND SPECIFICATIONS. SIGNATURE DATE STATEMENT OF GENERAL CONFORMANCE FOR ARCHITECTS/ENGINEERS WHO UTILIZE PLANS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PREPARED BY OTHER LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS (APPLICATION NO. _____________________FILE NO._________________) THE DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET INDICATED WITH AN ' * ' THIS DRAWING, PAGE OF SPECIFICATIONS/CALCULATIONS 1) DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND 2) COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FOR INCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT. THIS STATEMENT OF GENERAL CONFORMANCE "SHALL NOT BE CONSTRUED AS RELIEVING ME OF MY RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER SECTIONS 17302 AND 81138 OF THE EDUCATION CODE AND SECTIONS 4 - 336, 4 - 341 AND 4 - 344" OF TITLE 24, PART 1. (TITLE 24, PART 1, SECTION 4 - 317 [b]) HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARE LICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. IT HAS BEEN EXAMINED BY ME FOR: DSA 1R A - 18 ARCHITECTURE AND PLANNING WESTBERG + WHITE, INC. 14471 CHAMBERS ROAD TUSTIN, CALIFORNIA 92780 - 6964 (714) 508 - 1780 (714) 508 - 1790 FAX CONTACT: JOHN GARAKIAN, PROJECT MANAGER ELECTRICAL FBA ENGINEERING 150 PAULARINO AVENUE, SUITE A120 COSTA MESA, CA 92626 (949) 852 - 9995 (949) 852 - 1657 FAX CONTACT: ROBERT J. ROGERS, PRINCIPAL CONTACT INFORMATION Submittal Drawings January 21, 2021 A101 ENLARGED DEMO AND RENOVATION PLANS NEW: 1. FLOORING 2. ACOUSTICAL CEILING SYSTEM AND LIGHTING 3. POWER AND DATA PORTS ELECTRICAL * (5 Sheets) E000 SYMBOL LIST, NOTES SHEET INDEX AND DETAILS E001 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES AND DETAILS E100 ENLARGED LIGHTING AND FIRE ALARM PLANS E101 ENLARGED POWER AND SIGNAL PLANS E200 TITLE 24 FORMS A820 DETAILS A850 CEILING NOTES A851 CEILING DETAILS

BLDG 1000 IMPROVEMENTS - NOCCCD

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

NORTH

PROJECT LOCATION

0

1X

1

A101

1

A101

1

A101

GRID HEAD / LINES

DOOR TAG / NUMBER

WALL TYPE TAG

KEYNOTE TAG

REVISION TAG

A401

1

1

3

24 A601

ROOM TAG

EXTERIOR ELEVATION

INTERIOR ELEVATION

DETAIL REFERENCE

SECTION REFERENCE

CALLOUT DESIGNATION

ELEVATION NUMBER

SHEET NUMBER

ELEVATION NUMBER

SHEET NUMBER

DETAIL NUMBER

SHEET NUMBER

SECTION NUMBER

SHEET NUMBER

CALLOUT NUMBER

SHEET NUMBER

10' - 0"SPOT ELEVATION

9' - 0"CEILING HEIGHT TAG

COLOR TAGCMU-1SEE SHEET A702

1

101 ROOM NUMBER

ROOM NAME

101A

BN000

CEILING HEIGHT

PER REFLECTED

CEILING PLAN

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

NO

T FO

R C

ON

ST

RU

CT

IO

N

westbergwhitearchitecture

PDW

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:26 PM

G001

SHEET INDEX, SYMBOLS,ABBREVIATIONS, ANDNOTES

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

VICINITY MAPTYPICAL SYMBOLS

CENTERLINE& AND@ AT OR ABOUT' FOOT" INCH OR REPEAT# POUND OR NUMBER+/- VERIFY IN FIELDA.B. ANCHOR BOLTA.C. ASPHALTIC CONCRETEACC. ACCESSIBLEADJ. ADJUSTABLE / ADJACENTA.F.F. ABOVE FINISH FLOORAGGR. AGGREGATEALUM. ALUMINUMANOD. ANODIZEDAPPROX. APPROXIMATEARCH. ARCHITECTURALASPH. ASPHALTBD. BOARDBITUM. BITUMINOUSBLDG. BUILDINGBLK. BLOCKBLKG. BLOCKINGB.M. BENCHMARKBOT. BOTTOMB/S BOTH SIDESB.W. BOTH WAYSC.B. CATCH BASINCEM. CEMENTCLR. CLEARCONC. CONCRETE

IN. INCHINCND. INCANDESCENTINV. INVERTJT. JOINTLB. POUNDL.F. LINEAL FEETLLH. LONG LEG HORIZONTALLLV. LONG LEG VERTICALL.P. LOW POINTLT. LIGHTLT. WT. LIGHT WEIGHTMACH. MACHINEMAT. MATERIALMAX. MAXIMUMM.B. MACHINE BOLTMDF MAIN DISTRIBUTION FRAMEMED. MEDIUMMEMB. MEMBRANEMET. METALMFR. MANUFACTURERMH. MANHOLEMIN. MINIMUM / MINUTEMISC. MISCELLANEOUSMPOE MAIN POINT OF ENTRYMTD. MOUNTED(N) NEWNAT. NATURALNT. GR. NATURAL GRADEN.I.C. NOT IN CONTRACTNO. NUMBER

R.O. ROUGH OPENINGRWD. REDWOODS. SOUTH / SPANDRELS.C. SOLID CORESCHED. SCHEDULESECT. SECTIONSERV. SERVICE / SERVINGS.F. SQUARE FOOTSHT. SHEETSIM. SIMILARSL. SLIDINGSPEC. SPECIFICATIONSQ. SQUARES.S. STAINLESS STEELSTA. STATIONSTD. STANDARDSTL. STEELSTOR. STORAGESTRUCT. STRUCTURALSUSP. SUSPENDEDSYM. SYMMETRICALT.C. TOP OF CURB OR CONCRETETEL. TELEPHONETEMP. TEMPERED / TEMPORARYT&G TONGUE AND GROOVETHK. THICKTOIL. TOILETT.O.W. TOP OF WALLTYP. TYPICALTRNSF. TRANSFORMER

CONN. CONNECTIONCONSTR. CONSTRUCTIONCONT. CONTINUOUSCONTR. CONTRACTORCSK. COUNTERSUNKDBL. DOUBLEDEPT. DEPARTMENTDET. DETAILD.F. DRINKING FOUNTAINDIA. DIAMETERDIAG. DIAGONALDIM. DIMENSIONDISP. DISPENSER / DISPOSALDN. DOWNDR. DOORD.S.P. DRY STANDPIPEDWG. DRAWING(E) EXISTINGE. EAST / ENAMELEA. EACHEE EACH ENDE.G. EXISTING GRADEE.J. EXPANSION JOINTEL. ELEVATIONELEC. ELECTRICALELEV. ELEVATOR / ELEVATIONEMER. EMERGENCYENCL. ENCLOSUREE.O.S. EDGE OF SLABEQ. EQUALEQPT. EQUIPMENTE.S. EACH SIDE

E.W. EACH WAYEXIST. EXISTINGEXP. EXPANSIONEXPO. EXPOSEDFLUOR. FLUORESCENTFNDN. FOUNDATIONF.O.C. FACE OF CONCRETEF.O.F. FACE OF FINISHF.S. FULL SIZE / FINISH SURFACEFT. FOOT OR FEETFTG. FOOTINGFURR. FURRINGFUT. FUTUREGA. GUAGE / GAGEGALV. GALVANIZED IRONGEN GENERALG.I. GALVANIZED IRONGR. GRADEH.B. HOSE BIBBH.C. HOLLOW COREHDWD. HARDWOODHDWR. HARDWAREHGT. HEIGHTH.M. HOLLOW METALHORIZ. HORIZONTALH.P. HIGH POINTHR. HOURI.B.C INTERNATIONAL BUILDING CODEI.D. INSIDE DIAMETER / DIMENSIONIDF INTERMEDIATE DISTRUBUTION

NOM. NOMINALN.T.S. NOT TO SCALEO/ OVERO.A. OVERALL / OUTSIDE AIROBS. OBSCUREO.C. ON CENTERO.D. OUTSIDE DIAMETER / DIMENSIONORN. ORNAMENTAL IRONPH PANIC HARDWAREP.I.V. PRESSURE INDICATOR VALVEPL. PLATEPLUMB. PLUMBINGP.M. PRESSED METALPNL. PANELP/P PUSH-PULLPR. PAIRPREFAB. PREFABRICATEDPT. POINTR. RISER / RADIUSRAD. RADIUSREC. RECESSED / RECIEVINGRECPT. RECEPTACLEREF. REFERENCEREV. REVERSEREG. REGISTER / REGULARREINF. REINFORCEDREQ. REQUIREDRESIL. RESILIENTR.H. ROUND HEADRM. ROOM

U.L. UNDERWRITER'S LABUNFIN. UNFINISHEDU.N.O. UNLESS NOTED OTHERWISEVERT. VERTICALVEST. VESTIBULEV.I.F. VERIFY IN FIELDW. WEST / WOMENW/ WITHWD. WOODW/O WITHOUTWP. WATERPROOFW.R. WATER RESISTANTW.S. WOOD SCREWWT. WEIGHTW.W.M. WOVEN WIRE MESH

KEYNOTES SPECIFIC TO BUILDING WORK

BE BUILDING EXISTINGBD BUILDING DEMOLITIONBN BUILDING NEW

KEYNOTES SPECIFIC TO SITE WORK

SE SITE EXISTINGSD SITE DEMOLITIONSN SITE NEW 04-XXXXXX 30-C1

XX-XX-20

SCOPE OF WORK

THIS PROJECT CONSISTS OF BUT NOT LIMITED TO:

DEMOLITION:

1. PARTIAL DEMOLITION OF INTERIOR WALLS AND CEILINGS

G001 SHEET INDEX, SYMBOLS, ABBREVIATIONS, AND NOTES

G002 OVERALL SITE PLAN

(7 Sheets)ARCHITECTURAL

BLDG 1000 IMPROVEMENTS

North Orange County Community College District

A001 ENLARGED PARTIAL SITE PLAN

ABBREVIATIONS

SHEET INDEX

STATEMENT OF GENERAL CONFORMANCE

PRINT NAME

I FIND THAT: ALL DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET

THIS DRAWING OR PAGE

IS/ARE IN GENERALCONFORMANCE WITH THEPROJECT DESIGN, AND

LICENSE NUMBER

IS/ARE IN GENERALCONFORMANCE WITH THEPROJECT DESIGN INTENT, AND

SIGNATURE DATE

C11045

ARCHITECT OR ENGINEER DESIGNATED TO BE IN GENERAL RESPONSIBLE CHARGE

ARCHITECT OR ENGINEER DELEGATEDRESPONSIBILITY FOR THIS PORTION OFTHE WORK

LICENSE NUMBER EXPIRATION DATE

PRINT NAME

EXPIRATION DATE

Paul D. Westberg

SEPTEMBER, 2019

HAS/HAVE BEEN COORDINATEDWITH THE PROJECT PLANS ANDSPECIFICATIONS.

HAS/HAVE BEEN COORDINATEDWITH THE PROJECT PLANS ANDSPECIFICATIONS.

SIGNATURE DATE

STATEMENT OF GENERAL CONFORMANCE

FOR ARCHITECTS/ENGINEERS WHO UTILIZE PLANS,INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PREPARED BY OTHER

LICENSED DESIGN PROFESSIONALS AND/OR CONSULTANTS

(APPLICATION NO. _____________________FILE NO._________________)

THE DRAWINGS OR SHEETS LISTED ON THE COVER OR INDEX SHEET INDICATED WITH AN '*'

THIS DRAWING, PAGE OF SPECIFICATIONS/CALCULATIONS

1) DESIGN INTENT AND APPEARS TO MEET THE APPROPRIATE REQUIREMENTS OF TITLE 24, CALIFORNIA CODE OF REGULATIONS AND THE PROJECT SPECIFICATIONS PREPARED BY ME, AND

2) COORDINATION WITH MY PLANS AND SPECIFICATIONS AND IS ACCEPTABLE FORINCORPORATION INTO THE CONSTRUCTION OF THIS PROJECT.

THIS STATEMENT OF GENERAL CONFORMANCE "SHALL NOT BE CONSTRUED ASRELIEVING ME OF MY RIGHTS, DUTIES, AND RESPONSIBILITIES UNDER SECTIONS17302 AND 81138 OF THE EDUCATION CODE AND SECTIONS 4-336, 4-341 AND 4-344"OF TITLE 24, PART 1. (TITLE 24, PART 1, SECTION 4-317 [b])

HAVE BEEN PREPARED BY OTHER DESIGN PROFESSIONALS OR CONSULTANTS WHO ARELICENSED AND/OR AUTHORIZED TO PREPARE SUCH DRAWINGS IN THIS STATE. IT HASBEEN EXAMINED BY ME FOR:

DSA 1R A-18

ARCHITECTURE AND PLANNINGWESTBERG + WHITE, INC.

14471 CHAMBERS ROAD

TUSTIN, CALIFORNIA 92780-6964(714) 508-1780 (714) 508-1790 FAX

CONTACT: JOHN GARAKIAN, PROJECT MANAGER

ELECTRICALFBA ENGINEERING

150 PAULARINO AVENUE, SUITE A120

COSTA MESA, CA 92626(949) 852-9995 (949) 852-1657 FAX

CONTACT: ROBERT J. ROGERS, PRINCIPAL

CONTACT INFORMATION

Submittal DrawingsJanuary 21, 2021

A101 ENLARGED DEMO AND RENOVATION PLANS

NEW:

1. FLOORING2. ACOUSTICAL CEILING SYSTEM AND LIGHTING

3. POWER AND DATA PORTS

ELECTRICAL* (5 Sheets)

E000 SYMBOL LIST, NOTES SHEET INDEX AND DETAILS

E001 PARTIAL SINGLE LINE DIAGRAM, PANEL SCHEDULES AND DETAILS

E100 ENLARGED LIGHTING AND FIRE ALARM PLANSE101 ENLARGED POWER AND SIGNAL PLANS

E200 TITLE 24 FORMS

A820 DETAILS

A850 CEILING NOTES

A851 CEILING DETAILS

ASPH

ASPHASPHASPH

ASPH ASPH

ASPH

ASPHASPH

ASPH

ASPH

ASPH

ASPH

ASPH

ASPH

CONC

CONC

CONC

CONC

CONC

CONC

CONC

CONC

CONC

TS

TS

STAIR

STAIR

TS

PARKING STRUCTURE

TS

PP

PPPP

PP

PP

PP

PP

PP

PP

PP

PP

PPPP

PP PP

PP

PP

PP

PP

PP

PP

PP

DI

DI

FLAG

C SCCCCCCCCCCCCCCC SSSSS S S S S S S S SSS

N BERKELEY AVENUE

LE

MO

N S

TR

EE

T

NUTWOOD PL

E CHAPMAN AVENUE

N B

ER

KE

LE

Y A

VE

NU

E

FULLERTON COLLEGE DR

LE

MO

N S

TR

EE

T

E CHAPMAN AVENUE

N B

ER

KE

LE

Y A

VE

NU

E

1700

1400

900

700

840

800500

1200

400

200

1000

1300

1100

300

2300

1500

600

2200

100

2001

2000

WILSHIRE AUDITORIUM

W1W2 W3

2100

1955 - 1960

1901-1902

1903-1904

LA

WR

EN

CE

AV

E.

WILSHIRE AVENUE

BASEBALL FIELD SOFTBALL FIELD

SOCCER FIELD

1600

3000

3100

PARKING 4

PARKING 5

AQUATIC CENTER

PARKING B-2 EAST

PARKING 7

PARKING 8

TENNIS COURTS

SHERBECK FIELD

A001

1

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

NO

T FO

R C

ON

ST

RU

CT

IO

N

westbergwhitearchitecture

PDW

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:29 PM

G002

OVERALL SITE PLAN

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1" = 100'-0" 1OVERALL SITE PLAN

0 200' 400'100'

NORTH

ASPH

ASPH ASPH

TS

A101

3

E CHAPMAN AVENUE

1200400

200

1000

1955 - 1960

AQUATIC

CENTER

PARKING 8

AREA OF WORK

EXISTING BUILDING(S) NOT PART OF THIS CONRACT

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

NO

T FO

R C

ON

ST

RU

CT

IO

N

westbergwhitearchitecture

PDW

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:19 PM

A001

ENLARGED PARTIAL SITEPLAN

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1" = 20'-0" 1ENLARGED PARTIAL SITE PLAN

LEGENDGENERAL NOTES

FOR TYPICAL SYMBOLS AND ABBREVIATIONS, SEE SHEET G001.

PROVIDE TEMPORARY 6' HIGH CHAIN LINK FENCE ENCLOSURES WITH LOCKABLE GATES AS REQUIRED FOR CONSTRUCTION ACCESS AT CONTRACTOR'S STAGING AREA AND AROUND ALL CONSTRUCTION SITES AS DICTATED BY THE PHASING SCHEDULE.

WHERE REMOVAL OF CONCRETE WALKS, MOWSTRIPS, CURBS AND GUTTERS IS REQUIRED TO INSTALL UNDERGROUND UTILITIES, REMOVE THE CONCRETE WORK TO THE NEAREST EXISTING EXPANSION OR CONTROL JOINT (SAWCUT IF REQUIRED). MOWSTRIPS, CURBS AND GUTTERS MAY BE REMOVED IN MINIMUM LENGTHS OF 6' IF THE DISTANCE BETWEEN EXISTING JOINTS IS 12' OR MORE. REPLACE REMOVED WORK WITH REINFORCED CONCRETE TO MATCH ADJACENT EXISTING WORK IN PROFILE, JOINT LAYOUT AND FINISH.

ALL ITEMS SHOWN OR NOTED ARE EXISTING, UNLESS INDICATED OTHERWISE AS NEW.

PROTECT AND SAFEGUARD FROM DAMAGE ALL EXISTING FINISHES AND WORK TO REMAIN.

1.

2.

4.

5.

6.

COORDINATE THE REMOVAL, RELOCATION OR MODIFICATION OF EXISTING IRRIGATION LINES WITH THE DISTRICT PRIOR TO ANY TRENCHING, CLEARING AND GRUBBING, OR OTHER SITE EXCAVATIONS REQUIRED FOR NEW CONSTRUCTION.

7.

RUN-OFF FROM PETROLEUM PRODUCTS, LIME AND MORTAR, SOIL STERILANTS, AND THE WASHING OF EQUIPMENT USED TO APPLY THESE MATERIALS, IS PROHIBITED WITHIN PLANTED AREAS.

8.

CONTRACTOR SHALL MAINTAIN EXISTING PLANTING WITHIN THE JOB SITE FENCE ENCLOSURE DURING DEMOLITION AND CONSTRUCTION PHASES. EXISTING IRRIGATION SYSTEMS SHALL EITHER REMAIN OPERATIONAL FOR CONTRACTOR'S USE OR CONTRACTOR SHALL HAND-WATER EXISTING PLANT MATERIALS AT LEAST ONCE A WEEK. TURF SHALL BE MOWED AT LEAST ONCE EVERY TWO WEEKS.

9.

REPAIR EXISTING IRRIGATION SYSTEMS DAMAGED DURING THE EXECUTION OF THIS CONTRACT. REPLACE PLANT MATERIALS DAMAGED, DECLINING IN HEALTH, SUFFERING DIEBACK, THAT HAVE LOST FORM AND SIZE, OR THAT DIE DURING THE CONSTRUCTION PERIOD, WITH THE SAME SPECIE OF EQUAL OR GREATER SIZE.

11.

REPAIR ASPHALT PARKING LOTS, SPEED BUMPS AND PAINTED CROSSWALKS DAMAGED BY THE EXECUTION OF THIS CONTRACT TO ORIGINAL OR BETTER CONDITION. REPAINT CROSSWALKS AND SPEED BUMP STRIPING THEIR FULL LENGTHS ACROSS ROADWAYS.

12.

FOR SITE REPAIR WORK NOT SHOWN ON ARCHITECTURAL PLANS, SEE ELECTRICAL, PLUMBING AND MECHANICAL SITE PLANS.

10.

PROVIDE SPLASH BLOCKS AT ALL DOWNSPOUTS IN PLANTED AREAS.13.

MAXIMUM SLOPE ON NON-RAMPED CONCRETE IS 5% IN THE DIRECTION OF TRAVEL AND 2% CROSS-SLOPE.

14.

PROVIDE IRRIGATION SLEEVES UNDER HARDSCAPE AT "PLANTED AREAS" (WITHIN PROJECT LIMITS) - COORDINATE WITH DISTRICT.

15.

TREES, SHRUBS, TURF, AND IRRIGATION ARE BY THE DISTRICT. PRIOR TO THE START OF CONSTRUCTION THE CONTRACTOR SHALL COORDINATE PLANTING AND IRRIGATION WITH DISTRICT.

16.

FOR WATER SERVICE DURING CONSTRUCTION, CONTRACTOR SHALL OBTAIN TEMPORARY WATER METER FROM THE CITY OF LONG BEACH FOR CONNECTION TO EXIST. FIRE HYDRANT.

17.

GRATINGS LOCATED IN THE SURFACE OF ANY PEDESTRIAN WAY IN THE PATH OF TRAVEL, GRID/OPENINGS IN GRATINGS SHALL BE LIMITED TO 1/2" MAXIMUM CLEAR IN THE DIRECTION OF TRAFFIC FLOW. IF SUCH CONDITION OCCURS, PROVIDE MANUFACTURERS CUT-SHEETS REVIEW.

20.

19.

21.

SEE SHEET F001 FOR FIRE ACCESS PLAN AND CODE ANALYSIS3.

18.

ALL BARRIERS IN THE PATH OF TRAVEL HAVE BEEN REMOVED, WILL BE REMOVED, OR MODIFIED TO COMPLY WITH CBC SECTION 11B-402 UNDER THIS PROJECT. CONTRACTOR TO NOTIFY ARCHITECT IF ANY BARRIERS ARE DISCOVERED PRIOR TO PROCEEDING WITH WORK.

ALL UNCERTIFED (E) P.O.T. IN THE PROJECT SCOPE SHALL NOT EXCEED 5% MAXIMUM RUNNING SLOPE AND 2% MAXIMUM CROSS SLOPE UNLESS OTHERWISE NOTED. MAXIMUM SLOPE SHALL NOT EXCEED 2% IN ALL DIRECTIONS WHERE P.O.T. TRAFFIC FLOW IS MULTIDIRECTIONAL , AT CHANGE OF DIRECTIONS, OR IN ANY ACCESSIBLE SPACE OR AREA WITH SLOPES TO DRAINS OR CATCH BASINS, ETC. CONTRACTOR IS TO VERIFY P.O.T. SHOWN IS IN COMPLIANCE, SEE NOTE 19 BELOW.

PATH OF TRAVEL (P.O.T.) AS INDICATED IS A BARRIER FREE ROUTE WITHOUT ANY ABRUPT VERTICAL CHANGES EXCEEDING 1/2" BEVELED AT 1:2 MAXIMUM SLOPE, EXCEPT THAT LEVEL CHANGES DO NOT EXCEEDS 1/4" VERTICAL AND IS AT LEAST 48" WIDE . SURFACE IS SLIP RESISTANT, STABLE, FIRM AND SMOOTH. CROSS-SLOPE DOES NOT EXCEEDS 2% AND SLOPE IN THE DIRECTION OF TRAVEL IS LESS THAN 5% UNLESS OTHERWISE INDICATED (11B-403.3). (POT) SHALL BE MAINTAINED FREE OF OVERHANGING OBSTRUCTIONS TO 80" MINIMUM (11B-307.4) AND PROTRUDING OBJECTS GREATER THAN 4" PROJECTION FROM WALL AND ABOVE 27" AND LESS THAN 80" (11B-307.2) ARCHITECT TO VERIFY THAT ALL BARRIERS IN THE PATH OF TRAVEL HAVE BEEN REMOVED OR WILL BE REMOVED UNDER THIS PROJECT, AND PATH OF TRAVEL COMPLIES WITH CBC 11B-206.

DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE STATEMENT:THE POT IDENTIFIED IN THESE CONSTRUCTION DOCUMENTS IS COMPLIANT WITH THE CURRENT APPLICABLE CALIFORNIA BUILDING CODE ACCESSIBILITY PROVISIONS FOR PATH OF TRAVEL REQUIREMENTS FOR ALTERATIONS, ADDITIONS AND STRUCTURAL REPAIRS. AS PART OF THE DESIGN OF THIS PROJECT, THE POT WAS EXAMINED AND ANY ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WERE DETERMINED TO BE NONCOMPLIANT 1) HAVE BEEN IDENTIFIED AND 2) THE CORRECTIVE WORK NECESSARY TO BRING THEM INTO COMPLIANCE HAS BEEN INCLUDED WITHIN THE SCOPE OF THIS PROJECT’S WORK THROUGH DETAILS, DRAWINGS AND SPECIFICATIONS INCORPORATED INTO THESE CONSTRUCTION DOCUMENTS. ANY NONCOMPLIANT ELEMENTS, COMPONENTS OR PORTIONS OF THE POT THAT WILL NOT BE CORRECTED BY THIS PROJECT BASED ON VALUATION THRESHOLD LIMITATIONS OR A FINDING OF UNREASONABLE HARDSHIP ARE SO INDICATED IN THESE CONSTRUCTION DOCUMENTS. DURING CONSTRUCTION, IF POT ITEMS WITHIN THE SCOPE OF THE PROJECT REPRESENTED AS CODE COMPLIANT ARE FOUND TO BE NONCONFORMING BEYOND REASONABLE CONSTRUCTION TOLERANCES, THEY SHALL BE BROUGHT INTO COMPLIANCE WITH THE CBC AS A PART OF THIS PROJECT BY MEANS OF A CONSTRUCTION CHANGE DOCUMENT.”

NORTH

0 40' 80'20'

KEYNOTES

EXISTING SECT'Y

127A

EXISTING STOR.

127B

EXISTING OFFICE

127C

OFFICE

127D

(N.I.C.)

EXISTING WORK RM.

127

28' - 3"3' -

4"

10' -

9"

11' -

3"

14' -

7"

16' - 10"7' - 3"13' - 9"

24' - 1"

9' - 11"BD001

BD002BD002

BD003

BD003

BD004

BD005

TYP.

BD004

BD002BD002

LIMIT OF WORK

LIM

IT O

F W

OR

K

BE004

BE001

BE001

BE001

BE004

BD004BD004BD004OFFICE

127D

(N.I.C.)

669 SF

OPEN OFFICE

102

200 SF

PRIVATE OFFICE

101

LIMIT OF WORK

LIM

IT O

F W

OR

K

BN002

BE001

BE001

BE002

BE001

BE002

BN010

BE002 TYP.

BE002

BN006

BN006

BN004

BN004

BN004

BE004

BE004

BE002

BN004

BN008BN008

TYP.

BN009

TYP.

BN008BN008

BN009 TYP.

BN006

BN009 TYP.

BN002

BN007

3' - 6"

BE006

BE006

6"

BN011

EXISTING WALL TO REMAIN

FURNITURE N.I.C.

MODULAR FURNITURE PROVIDED BY AND INSTALLED BY COLLEGE

EXISTING WALL TO BE REMOVED

REMOVE DOOR AND FRAME ASSEMBLY

EXISTING CASEWORK TO BE REMOVED

EXISTING LIGHT FIXTURE TO BE REMOVED

EXISTING MECHANICAL REGISTERS TO BE REMOVED

RENOVATION

DEMOLITION

NEW LIGHT FIXTURE

NEW MECHANICAL REGISTERS

NEW WALL

BD010

BD008

BD009 TYP.

TYP.

TYP.

TYP.BD010

BD008

BD009

TYP.

TYP.

LIMIT OF WORK

LIM

IT O

F W

OR

K

BE005BE005BE005

BD009

BD010TYP.

TYP.

TYP.

BD008 TYP.

BE002

BE002BE004BE004

BE002

BE002

BD001

BD001

LIMIT OF WORK

LIM

IT O

F W

OR

K

BN001

BN003

BN005

BN001

BN003

BN005 TYP.

TYP.

TYP.

TYP.

TYP.

TYP.

6

A820

6

A820

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

NO

T FO

R C

ON

ST

RU

CT

IO

N

westbergwhitearchitecture

PDW

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:22 PM

A101

ENLARGED DEMO ANDRENOVATION PLANS

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1/4" = 1'-0" 1DEMOLITION FLOOR PLAN 1/4" = 1'-0" 3RENOVATION FLOOR PLAN LEGEND

BD001 REMOVE (E) FINISH, STUDS, INSULATION AND ANCHORS.

BD002 REMOVE (E) FLOORING FINISH AND WALL BASE.

BD003 REMOVE (E) DOOR, FRAME, HARDWARE AND ANCHORS.

BD004 REMOVE (E) CASEWORK IN ITS ENTIRETY.

BD005 REMOVE (E) CASEWORK WITH SINK AND ASSOCIATED PLUMBING LINES.

BD008 REMOVE (E) CEILING SYSTEMS, LIGHT FIXTURES, REGISTERS, SPEAKERS AND ALL ASSOCIATED COMPONENTS.

BD009 REMOVE (E) MECHANICAL REGISTERS, TO BE REPLACED.

BD010 REMOVE (E) LIGHT FIXTURES AND ALL ASSOCIATED PARTS, TYP.

BE001 (E) DOOR TO REMAIN. PROTECT IN PLACE

BE002 (E) WALL TO REMAIN, PROTECT IN PLACE. PATCH,REPAIR AND PAINT AS REQUIRED.

BE004 (E) WINDOW TO REMAIN. PROTECT IN PLACE

BE005 (E) MECHANICAL DUCTING TO REMAIN. PROTECT IN PLACE.

BE006 (E) COLUMN TO REMAIN, PROTECT IN PLACE.

BN001 INSTALL (N) LIGHT FIXTURE, TYP. REFERENCE ELECTRICAL DRAWINGS FOR DETAILS.

BN002 INSTALL (N) DOOR/ROOM SIGNAGE. SEE ROOM SIGNAGE DETAIL 1/A820. MATCH (E) SIGNAGE VERBIAGE IN KIND.

BN003 PROVIDE (N) MECHANICAL DIFFUSERS AND REGISTER PER DISTRICT STANDARDS

BN004 PATCH, REPAIR AND PAINT ALL (E) WALL SURFACES, AS REQUIRED

BN005 INSTALL (N) SUSPENDED CEILING SYSTEM,TYP.

BN006 PROVIDE (N) PAINT ON (E) DOORS, SEE COLOR SCHEDULE FOR DETAILS.

BN007 CAP (E) WATER SUPPLIES IN WALL AND CAP WASTE BELOW FLOOR. PATCH WALL AND FLOOR PER RENNOVATION PLANS.

BN008 INSTALL (N) CARPET PER COLOR SCHEDULE.

BN009 (N) MODULAR FURNITURE N.I.C., PROVIDED AND INSTALLED BY DISTRICT.

BN010 PROVIDE (N) 6" METAL STUD FURRING WITH 5/8" TYPE 'X' GYP. FINISH AT EXPOSED FACE

BN011 PROVIDE (N) ELECTRICAL PANEL AND MAINTAIN 3' CLEAR SPACE

1. FOR TYPICAL SYMBOLS AND ABBREVIATIONS, SEE SHEET G001.

ALL GYPSUM BOARD SHALL BE 5/8" THICK TYPE "X" (U.N.O.).

SEE FINISH SCHEDULE ON DETAIL 8A/A101 FOR ADDITIONAL FINISHES OVER 5/8" "X" GYPSUM BOARD.

PROVIDE FIRE-RESISTANT SEALANT MATERIAL AT ALL PENETRATIONS THROUGH FIRE WALLS, FIRE BARRIERS, CORRIDOR WALLS AND RATED HORIZONTAL ASSEMBLIES.

2.

3.

4.

ALL DIMENSIONS TO EXTERIOR WALLS ARE TO FACE OF STUD U.N.O.5.

6.

7.

PROTECT AND SAFEGUARD FROM DAMAGE ALL EXISTING FINISHES AND WORK TO REMAIN.

FOR ADDITIONAL ROOM SIGNAGE NOT SHOWN, SEE DETAIL 9/A003.

8. INTERIOR SIDE OF ALL CMU WALLS (AND BOTH SIDES OF INTERIOR CMU WALLS) TO BE FLUSH GROUTED, SEALED AND PAINTED.

9. ALL EXPOSED INTERIOR MASONRY WALLS TO BE PRIMED AND PAINTED

10. ALL ROOF ELEVATIONS ARE ABOVE FIRST FINISH FLOOR

GENERAL NOTES

KEYNOTES

1/4" = 1'-0" 2DEMOLITION REFLECTED CEILING PLAN 1/4" = 1'-0" 4RENOVATION REFLECTED CEILING PLAN

DIFFUSER, REGISTERS AND GRILLES:

1. MANUFACTURER TO BE KRUEGER, PER DISTRICT STANDARDS

2. ALL REGISTERS/ DIFUSERS IN A SINGLE ROOM SHALL HAVE THE SAME SIZE AND NUMBER OF SLOTS.

3. DIFFUSERS: SQUARE MODULAR CORE, ADJUSTABLE DIRECTION PATTERN TYPE DIFFUSER WITH OPPOSED BLADE VOLUME DAMPER. FILLER PANEL MOUNT FOR T BAR LAY-IN APPLICATION. FABRICATE OF STEEL WITH BAKED ENAMEL FINISH.

4. RETURN REGISTERS: T BAR LAY-IN APPLICATION - PERFORATED FACE WITH OPPOSED BLADE VOLUME DAMPER, FABRICATE

OF STEEL WITH BAKED ENAMEL FINISH.

ATYPE

NOTE #1:COLORS TO BE SELECTED BY THE ARCHITECTS. NOTE #2: PROVIDE EASED EDGES ON GEOMETRIC SYMBOLS.

9"

NAME

123

ROOM

6"

3/8

"1/2

"1"

5/8" HIGH TACTILE LETTERING, RAISED 1/32"

(COORDINATE ROOM NAMES WITH DISTRICT)

5'-

0"

TO

CEN

TER

LIN

E O

F S

IGN

INSTALL PERMANENT TACTILE IDENTIFICATION

SIGNAGE ON THE WALL SURFACE ADJACENT TO

THE LATCH SIDE OF THE DOOR AS SHOWN. AT

DOUBLE DOORS, PLACE SIGNS ON THE RIGHT

SIDE. THE MOUNTING LOCATION MUST ALLOW A PERSON TO APPROACH WITHIN 3" OF THE SIGN

WITHOUT ENCOUNTERING PROTRUDING

OBJECTS OR STANDING WITHIN THE SWING OF

THE DOOR, U.N.O.

DOOR SIDELIGHT WHERE OCCURS

EQ EQ

RESTROOM SIGN WHERE OCCURS

PER S

IGN

AG

E P

LAN

4' -

6"

LO

CATIO

NACCESSIBLE ENTRANCE SIGN, WHERE OCCURS

9"

NOTES:

1.

LETTERS SHALL BE UPPER CASE, OFFICINA SANS BOOK FONT TYPE. AT TACTILE SIGN LOCATIONS SIGN SHALL BE

ACCOMPANIED BY CALIF. CONTRACTED GRADE 2 BRAILLE WITH CHARACTER TYPE AND HEIGHT PER DETAIL ON THIS SHEET.

3.

INSTALL ALL EXIT AND EXIT ROUTE SIGNAGE ON WALL AT INTERIOR SIDE OF ROOM

SIGNS ADHESIVELY APPLIED TO GLASS SHALL HAVE ADDITIONAL PLASTIC BACKING SAME SIZE AS SIGN ADHESIVELY

APPLIED TO OTHER SIDE OF GLASS.

2.

SIGN MATERIAL SHALL BE MIN. 1/4" THICK ACRYLIC PLASTIC WITH SURFACE PAINTED FINISH. SIGN GRAPHICS, NUMBERS

AND LETTERS SHALL BE RAISED 1/32" .

4.

INSTALL ALL ROOM NAME/NUMBER SIGNAGE ON WALL AT EXTERIOR SIDE OF ROOM U.N.O.

SIGN BACKGROUND SHALL HAVE A 70% MIN. CONTRAST COLOR W/ TEXT LETTERS AND BORDER W/ NON GLARE FINISH.5.

6.

ALL SIGNAGE TO BE ATTACHED WITH 3M VHB TAPE AND SILCONE ADHESIVE.7.

VERIFY SIGN TEXT AND ROOM NUMBER WITH OWNER.8.

REFER TO DETAIL 5G/G005 FOR MULTI LINE TEXT SIGNAGE REQUIREMENTS.9.

10. PROVIDE EASED EDGES ON ALL SIDES OF SIGNAGE.

MEN

60" MAX.A.F.F. TYP.

MIN

.

3/8

"

48" MIN.A.F.F. TYP.

BOTT. OF LOWEST BRAILLE ROWM

IN.

3/8

"

BOTT. OF LETTERING HIGHEST ROW

CHARACTER TYPE: CHARACTERS ON SIGNS SHALL BE RAISED 1/32 INCH MINIMUM AND SHALL BE SANS

SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE.

CHARACTER HEIGHT: RAISED CHARACTERS SHALL BE A MINIMUM OF 5/8 INCH AND A MAXIMUN OF 2

INCHES HIGH.

FINISH AND CONTRAST: CONTRAST BETWEEN CHARACTERS, SYMBOLS AND THEIR BACKGROUND MUST

BE 70% MINIMUM AND HAVE A NON-GLARE FINISH. (11B-703.5.1)

1.

2.

3.

BRAILLE: CONTRACTED CALIFORNIA GRADE 2 BRAILLE SHALL BE USED WHENEVER BRAILLE IS

REQUIRED IN OTHER PORTIONS OF THESE STANDARDS. DOTS SHALL BE 1/10 INCH ON CENTERS

IN EACH CELL WITH 2/10 INCH SPACE BETWEEN CELLS, MEASURED FROM THE SECOND COLUMN OF DOTS IN THE FIRST CELL TO THE FIRST COLUMN OF DOTS IN THE SECOND CELL. DOTS

SHALL BE RAISED A MINIMUM OF 1/40 INCH ABOVE THE BACKGROUND. (11B-703.3).

4.

BRAILLE CELL BRAILLE DOT

INTRA-CELL

.025"

-

ROUNDED DOT

(ACCEPTABLE)

SQUARE DOT

(NOT ACCEPTABLE)VERTICAL OR

HORIZONTAL

REQUIRED ROUNDED OR DOMED CALIFORNIA BRAILLE DOTS, EACH DISTINCT AND SEPARATE.

DOTS WITH STRAIGHT SIDES AND FLAT TOPS ARE NOT READABLE FOR MANY BRAILLE USERS.

INTER-CELL SPACING = .20" SPACING = .10"VERTICAL OR

HORIZONTAL

.037"

SUBSURFACE APPLIED COMPUTER CUT 3M SCOTCHCAL OPAQUE VINYL BACKER

SIGN

INT.EXT.

NOTE: FOR APPLICATION TO GLASS PROVIDE A MATCHING BACK-UP PLATE & MOUNT TO INTERIOR SURFACE OF GLASS WITH ADHESIVE.

DETAIL B

1. FOR MOUNTING SIGNAGE AT WINDOW SEE DETAIL B.2. VERIFY ALL SIGN TEXT WITH DISTRICT PRIOR TO MANUFACTURING SIGNAGE.3. PROVIDE AN ADDITIONAL 10 BUILDING SIGNS WITH 40 CHARACTERS PER SIGN TO BE DETERMINED DURING CONSTRUCTION PER THE DISTRICT'S DIRECTION.

SIGN

WALL PER PLAN

ATTACH TO WALL WITH 3M VHB TAPE AND SILICONE ADHESIVE

DETAIL A

GLAZING

NOTES:

(E) CONCRETE WALL

1/4" DIA. x 2.5" MIN. EMBED SIMPSON

TITEN HD (ICC-ES-ESR #1056) @ 8"

O.C., TYP.

ROLLER SHADE

RS-1

(E) WINDOW SYSTEM

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

NO

T FO

R C

ON

ST

RU

CT

IO

N

westbergwhitearchitecture

PDW

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:23 PM

A820

DETAILS

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

COLOR SCHEDULE

SPECIFICATION SECTION MFG / PRODUCT LOCATION DESIGNATION COLOR FINISH / MATERIAL REMARKS

09 9100

PAINTINGP-1

P-2

DUNN EDWARDS PAINT

DUNN EDWARDS PAINT

DEW 340 WHISPER

DEC 717 BAKED POTATO

ALL INTERIOR WALLS EGGSHELL

EGGSHELLINTERIOR DOORS AND DOOR

AND WINDOW TRIMS

09 5100

ACOUSTICAL CEILINGS

USG CEILING SOLUTIONS ALL AREAS ACP-1 MARS HIGH-NRC/ HIGH-CAC

COLOR: WHITE

SIZE: 24" X 24"

09 6800

CARPET

TANDUS CARPET ALL AREAS CPT-1 STYLE: AFTERMATH

COLOR:

RWB-2 COLOR: 283 TOAST RUBBER BASEALL CARPETED SPACES

SIZE: 24" X 24" TILE

STRAIGHT 4.5 INCHES HIGH

RS-112 2413

ROLLER SHADES

DRAPER/ROLLER SHADES ALL WINDOWS COLOR: BASIC (BASIC - P04)

WHITE/BONE, OPACITY: 3%

FIRST FLOORROOM FLOOR WALL FINISH CEILING

CASEWORK FACE

MATERIAL

COUNTERTOP

MATERIAL REMARKSNO. NAME FINISH BASE

NORTH EAST SOUTH WEST

MAT'L FINFIN MAT'L FIN MAT'L FIN MAT'L FIN MAT'L101 PRIVATE OFFICE CPT RWB PE GB PE GB PE GB PE GB ACP FF

102 OPEN OFFICE CPT RWB PE GB PE GB PE GB PE GB ACP FF

FINISH SCHEDULE

3" = 1'-0" 1TYPICAL ROOM SIGNAGE TYPES

1/2" = 1'-0" 2ROOM SIGNAGE NOTES

3" = 1'-0" 4ROOM SIGNAGE BRAILLE NOTES

3" = 1'-0" 3ROOM SIGNAGE INSTALL NOTES

3" = 1'-0" 6ROLLER SHADES

FLOOR/BASE:

CPT CARPETFF FACTORY FINISHRWB RUBBER WALL BASE

WALL/CEILING:ACP ACOUSTICAL CEILING PANEL - SEE R.C.P. FOR SIZESFF FACTORY FINISHGB 5/8" TYPE 'X' GYPSUM WALLBOARDPF PAINT FLAT PE PAINT EGGSHELLPSG PAINT SEMI-GLOSSPG PAINT GLOSS

FINISH ABBREVIATIONS

JOHNSONITE RUBEBR BASE

1. GENERAL REQUIREMENTS: CBC SECTION 1616A.1.21(1616.10.16*) REQUIRES THE DESIGN AND INSTALLATION TO BE INCOMPLIANCE WITH ASTM C635, C636, AND E580, SECTION 5, WITHMODIFICATIONS.NOTE: AMENDMENTS IN CBC SECTION 1616A.1.21 (1616.10.16*)REPLACE AND APPEND ASCE 7, SECTION 13.5.6.THE REQUIREMENTS IN THIS IR APPLY TO FLAT AND LEVEL CEILINGSYSTEMS WHOSE TOTAL WEIGHT, INCLUDING CEILING MOUNTED AIRTERMINALS, SERVICES AND LIGHT FIXTURES, DOES NOT EXCEED FOUR(4) PSF. HEAVIER SYSTEMS, SYSTEMS THAT ARE NOT FLAT AND LEVEL,THOSE SUPPORTING LATERAL LOADS FROM PARTITIONS, AND FREEFLOATING CEILINGS SUPPORTED BY CHAINS OR CABLES, ARE BEYONDTHE MINIMUM REQUIREMENTS OF THIS IR AND WILL REQUIRE SPECIALDESIGN AND DETAILS.

2. CEILING DESIGN & INSTALLATION REQUIREMENTS.2.1 CEILING SYSTEM COMPONENTS:

a) SHALL COMPLY WITH ASTM C635 AND SECTION 5.1 OF ASTM E580.b) THE CEILING GRID SYSTEM MUST BE RATED HEAVY DUTY AS

DEFINED BY ASTM C635.c) MAIN RUNNERS, CROSS RUNNERS, SPLICES, EXPANSION

DEVICES, AND INTERSECTION CONNECTORS SHALL BE DESIGNEDTO CARRY A MEAN ULTIMATE TEST LOAD OF NOT LESS THAN 180LBS. IN COMPRESSION AND TENSION PER ASTM E580 SECTION5.1.2.

d) CEILING WIRE SHALL BE CLASS 1 ZINC COATED (GALVANIZED)CARBON STEEL CONFORMING TO ASTM A641. WIRE SHALL BE #12GAGE (0.106" DIAMETER) WITH SOFT TEMPER AND MINIMUMTENSILE STRENGTH = 70 KSI. THE MAXIMUM ALLOWABLE (ASD)TENSION LOAD FOR WIRE MEETING THIS SPECIFICATION IS 350POUNDS.

• FOUR (4) TURNS OF THE WIRE WITHIN 1.5" WILL DEVELOP THEWIRE ALLOWABLE LOAD.

• THREE (3) TURNS OF THE WIRE WITHIN 3" IS ASSUMED TODEVELOP NO MORE THAN 50 PERCENT OF WIRE ALLOWABLELOAD.

2.2 SUSPENSION SYSTEM INSTALLATION:a) SHALL COMPLY WITH ASTM C636 AND SECTION 5.2 OF ASTM E580.b) #12 GAGE HANGER WIRES MAY BE USED FOR UP TO AND

INCLUDING A 4 FOOT BY 4 FOOT GRID SPACING AND SHALL BEATTACHED TO MAIN RUNNERS. SPLICES IN HANGER WIRES SHALLDEVELOP 50 PERCENT OF THE WIRE ALLOWABLE LOAD.

c) PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF ALL MAINAND CROSS RUNNERS WITHIN EIGHT (8) INCHES OF THE SUPPORTOR WITHIN ONE-FOURTH (1/4) OF THE LENGTH OF THE END TEE,WHICHEVER IS LEAST, FOR THE PERIMETER OF THE CEILING AREA. PERIMETER WIRES ARE NOT REQUIRED WHEN THE LENGTH OFTHE END TEE IS EIGHT (8) INCHES OR LESS.

d) CEILING GRID MEMBERS SHALL BE ATTACHED TO TWO (2)ADJACENT WALLS PER ASTM E580, SECTION 5.2.3. CEILING GRIDMEMBERS SHALL BE AT LEAST 3/4 INCH CLEAR OF OTHER WALLS.IF WALLS RUN DIAGONALLY TO CEILING GRID SYSTEM RUNNERS,ONE END OF MAIN AND CROSS RUNNERS SHOULD BE FREE, AND AMINIMUM OF 3/4 INCH CLEAR OF WALL.

e) THE WIDTH OF THE PERIMETER SUPPORTING CLOSURE ANGLESHALL BE NOT LESS THAN TWO (2) INCHES. USE OF ANGLESWITH SMALLER WIDTHS IN CONJUNCTION WITH PROPRIETARYPERIMETER CLIPS MAY BE ACCEPTABLE IN ACCORDANCE WITHSECTION 5 OF THIS IR.

f) AT THE PERIMETER OF THE CEILING AREA, WHERE MAIN ORCROSS RUNNERS ARE NOT CONNECTED TO THE ADJACENT WALL,PROVIDE INTERCONNECTION BETWEEN THE RUNNERS AT THEFREE END TO PREVENT LATERAL SPREADING. A METALSTABILIZER OR A #16 GAGE WIRE WITH A POSITIVE MECHANICALCONNECTION TO THE RUNNER MAY BE USED AND PLACED WITHINEIGHT (8) INCHES OF THE WALL. WHERE THE PERPENDICULAR

DISTANCE FROM THE WALL TO THE FIRST PARALLEL RUNNER ISEIGHT (8) INCHES OR LESS, THE STABILIZER OR #16 GAGE WIRE

IS NOT REQUIRED.

2.3 LATERAL FORCE BRACING ASSEMBLY INSTALLATION:a)LATERAL FORCE BRACING ASSEMBLIES CONSISTING OF A

COMPRESSION STRUT AND FOUR (4) #12 GAGE SPLAYED

BRACING WIRES ORIENTED 90 DEGREES FROM EACH OTHERARE REQUIRED FOR ALL CEILING AREAS.

EXCEPTION: LATERAL FORCE BRACING MAY BE OMITTED FORSUSPENDED ACOUSTICAL CEILING SYSTEMS WITH A CEILING

AREA NOT TO EXCEED 144 SQUARE FEET, FOR ALL VALUES OF SDS

WHEN PERIMETER SUPPORT IS PROVIDED IN ACCORDANCE WITHSECTION 2.2 OF THIS IR AND PERIMETER WALLS ARE

DESIGNED TO CARRY THE CEILING LATERAL FORCES.b) LATERAL FORCE BRACING ASSEMBLIES SHALL BE SPACED PER

DETAIL 2.12/A851 FOR ALL VALUES OF THE COMPONENT IMPORTANCE

FACTOR (IP) OF THE CEILING.c) THERE SHALL BE A BRACE ASSEMBLY A DISTANCE OF NOT MORE

THAN ONE HALF OF THE ABOVE SPACING FROM EACHSURROUNDING WALL, EXPANSION JOINT AND AT THE EDGES OFANY CEILING VERTICAL OFFSET. FOR EXAMPLE, WHERE THE

BRACE SPACING IS 8' X 12', THE EDGE DISTANCE SHALL BE 4FEET IN THE DIRECTION OF THE 8 FOOT SPACING AND 6 FEET IN

THE DIRECTION OF THE 12 FOOT SPACING.d) THE SLOPE OF BRACING WIRES SHALL NOT EXCEED 45 DEGREES

FROM THE HORIZONTAL PLANE AND WIRES SHALL BE TAUT.SPLICES IN BRACING WIRES SHALL DEVELOP THE WIRE

ALLOWABLE LOAD.e) COMPRESSION STRUTS SHALL MEET THE FOLLOWING

REQUIREMENTS:

• THE STRUT SHALL BE SIZED TO ADEQUATELY RESIST THE

VERTICAL COMPONENT FORCE INDUCED BY THE CEILINGBRACING WIRES AND HAVE A MAXIMUM KL/R NOT TO EXCEED

300. THE STRUTS LISTED IN APPENDIX A MEET THISREQUIREMENT FOR CEILINGS COMPLYING WITH THE GENERAL

REQUIREMENTS OF THIS IR.

• THE STRUT SHALL NOT BE MORE THAN ONE (HORIZONTAL) INSIX (VERTICAL) OUT OF PLUMB.

FOOTNOTES:

a. WHERE, AS DEFINED IN ASCE 7, SECTION 13.3.1:

Z = HEIGHT IN STRUCTURE OF POINT OF ATTACHMENT OFCEILING WITH RESPECT TO THE BASE. H = AVERAGE ROOF

HEIGHT OF THE STRUCTURE WITH RESPECT TO THE BASE.b. IT SHALL BE PERMITTED TO USE THE BRACE ASSEMBLY SPACING

FOR “Z/H > 0.5” FOR THE FULL BUILDING HEIGHT.

2.4 ATTACHMENT OF HANGER AND BRACING WIRES:a) FASTEN HANGER WIRES WITH NOT LESS THAN THREE (3) TIGHT

TURNS IN THREE (3) INCHES. HANGER WIRE LOOPS SHALL BETIGHTLY WRAPPED AND SHARPLY BENT TO PREVENT ANY

VERTICAL MOVEMENT OR ROTATION OF THE MEMBER WITHIN THE

LOOPS (SEE ASTM E580, SECTION 5.2.7.2).b) FASTEN BRACING WIRES WITH NOT LESS THAN FOUR (4) TIGHT

TURNS IN ONE AND ONE-HALF (1-1/2) INCHES.c) HANGER AND BRACING WIRE ANCHORAGE TO THE STRUCTURE

SHALL BE INSTALLED IN SUCH A MANNER THAT THE DIRECTIONOF THE ANCHORAGE ALIGNS CLOSELY WITH THE DIRECTION OF

THE WIRE. (E.G. BRACING WIRE CEILING CLIPS MUST BE BENT ASSHOWN IN THE DETAILS AND ROTATED AS REQUIRED TO ALIGN

CLOSELY WITH THE DIRECTION OF THE WIRE, SCREW EYES INWOOD MUST BE INSTALLED SO THEY ALIGN CLOSELY WITH THE

DIRECTION OF THE WIRE, ETC.).d) SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST

SIX (6) INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT,

ETC.e) HANGER AND BRACING WIRES SHALL NOT ATTACH TO OR BEND

AROUND OBSTRUCTIONS INCLUDING BUT NOT LIMITED TO:

PIPING, DUCTWORK, CONDUIT AND EQUIPMENT. PROVIDETRAPEZE OR OTHER SUPPLEMENTARY SUPPORT MEMBERS AT

OBSTRUCTIONS TO ALLOW TYPICAL HANGER SPACING. BRACEASSEMBLIES MUST BE CONFIGURED AND/OR LOCATED IN ORDERTO AVOID OBSTRUCTIONS IN ADDITION TO MAINTAINING THE

REQUIRED BRACE ASSEMBLY SPACING.f) PROVIDE ADDITIONAL HANGERS, STRUTS AND BRACE

ASSEMBLIES AS REQUIRED AT ALL CEILING BREAKS, SOFFITS, OR

DISCONTINUOUS AREAS.g)HANGER WIRES THAT ARE MORE THAN ONE (HORIZONTAL) IN SIX

(VERTICAL) OUT OF PLUMB SHALL HAVE COUNTER-SLOPING

WIRES.NOTE: SEE ASTM C636, FIGURE 1, FOR COUNTER-SLOPING

METHODS.h) ATTACHMENT OF THE BRACING WIRES TO THE STRUCTURE ABOVEAND TO THE MAIN RUNNERS SHALL BE ADEQUATE FOR THE LOAD

IMPOSED. THE WEIGHT (WP) SHALL BE TAKEN AS NOT LESS THAN

FOUR (4) PSF FOR CALCULATING SEISMIC FORCES (FP).i) POST-INSTALLED ANCHORS (E.G. EXPANSION ANCHORS, SCREW

ANCHORS AND POWER ACTUATED FASTENERS) SHALL HAVE A

CURRENT EVALUATION REPORT ACCEPTABLE TO DSA IN

ACCORDANCE WITH IR A-5.j) POWER-ACTUATED FASTENERS IN CONCRETE ARE NOT PERMITTED

FOR BRACING WIRES.

k) DSA APPROVAL OF A CONSTRUCTION PLAN IS REQUIRED PRIORTO INSTALLING POST-INSTALLED ANCHORS IN PRESTRESSED

CONCRETE. THE CONSTRUCTION PLAN SHALL DEMONSTRATE HOWTHE LOCATION OF EXISTING PRESTRESSING TENDONS AND

STRANDS WILL BE LOCATED AND DENOTED AS NECESSARY TO

AVOID INTERFERENCE.

2.5 EXPANSION JOINTS, SEISMIC SEPARATION JOINTS:a) EXPANSION JOINTS SHALL BE PROVIDED IN THE CEILING AT

INTERSECTIONS OF CORRIDORS AND AT JUNCTIONS OF

CORRIDORS AND LOBBIES OR OTHER SIMILAR AREAS.b) FOR CEILING AREAS EXCEEDING 2,500 SQUARE FEET, A SEISMIC

SEPARATION JOINT SHALL BE PROVIDED TO DIVIDE THE CEILING

INTO AREAS NOT EXCEEDING 2,500 SQUARE FEET IN

ACCORDANCE WITH ASTM E580, SECTION 5.2.9.

2.6 CEILING FIXTURES, TERMINALS, AND DEVICES:a) ALL FIXTURES, TERMINALS, AND OTHER DEVICES SHALL BE

MOUNTED IN A MANNER THAT WILL NOT COMPROMISE CEILING

PERFORMANCE IN ACCORDANCE WITH SECTION 13.5.6.2.2 ITEM 5OF ASCE 7 AS AMENDED BY CBC SECTION 1616A.1.20

(1616.10.16*) AND ASTM E580 SECTIONS 5.3 AND 5.4.b) CEILING PANELS SHALL NOT SUPPORT ANY LIGHT FIXTURES, AIR

TERMINALS OR DEVICES.c) PENETRATIONS THROUGH THE CEILING FOR SPRINKLER HEADS

AND OTHER SIMILAR DEVICES THAT ARE NOT INTEGRALLY TIED

TO THE CEILING SYSTEM IN THE LATERAL DIRECTION SHALL HAVEA TWO (2) INCH OVERSIZED RING, SLEEVE OR ADAPTER

THROUGH THE CEILING TILE TO ALLOW FREE MOVEMENT OF ONE(1) INCH IN ALL HORIZONTAL DIRECTIONS. ALTERNATIVELY, PER

ASTM E580, SECTION 5.2.8.5, A FLEXIBLE SPRINKLER HOSEFITTING THAT CAN ACCOMMODATE ONE (1) INCH OF CEILING

MOVEMENT SHALL BE PERMITTED TO BE USED IN LIEU OF THE

OVERSIZED RING, SLEEVE, OR ADAPTER.d) SLACK SAFETY WIRES SHALL BE CONSIDERED HANGER WIRES

FOR INSTALLATION AND TESTING REQUIREMENTS.

2.6.1 LIGHT FIXTURES:a) ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE

CEILING SUSPENSION SYSTEMS BY MECHANICAL MEANS PER CEC

ARTICLE 410.36 TO RESIST A HORIZONTAL FORCE EQUAL TO THEWEIGHT OF THE FIXTURE. A MINIMUM OF TWO SCREWS OR

APPROVED FASTENERS ARE REQUIRED AT EACH LIGHT FIXTURE,

PER ASTM E580, SECTION 5.3.1.b) SURFACE-MOUNTED LIGHT FIXTURES SHALL BE ATTACHED TO THE

MAIN RUNNER WITH AT LEAST TWO POSITIVE CLAMPING DEVICESON EACH FIXTURE. THE CLAMPING DEVICE SHALL COMPLETELY

SURROUND THE SUPPORTING CEILING RUNNER AND BE MADE OFSTEEL WITH A MINIMUM THICKNESS OF #14 GAGE. ROTATIONAL

SPRING CATCHES DO NOT COMPLY. A #12 GAGE SLACK SAFETYWIRE SHALL BE CONNECTED FROM EACH CLAMPING DEVICE TO

THE STRUCTURE ABOVE. PROVIDE ADDITIONAL SUPPORTS WHENLIGHT FIXTURES ARE EIGHT (8) FEET OR LONGER OR EXCEED 56

LB. MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED

EIGHT (8) FEET.c) LIGHT FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB.

SHALL HAVE A MINIMUM OF ONE #12 GAGE SLACK SAFETY(1)

WIRE CONNECTED FROM THE FIXTURE HOUSING TO THE

STRUCTURE ABOVE.d) LIGHT FIXTURES WEIGHING GREATER THAN 10 LB. BUT LESS

THAN OR EQUAL TO 56 LBS. MAY BE SUPPORTED DIRECTLY ONTHE CEILING RUNNERS, BUT THEY SHALL HAVE A MINIMUM OF

TWO (2) #12 GAGE SLACK SAFETY WIRES CONNECTED FROM THEFIXTURE HOUSING AT DIAGONAL CORNERS TO THE STRUCTURE

ABOVE.EXCEPTION: ALL LIGHT FIXTURES GREATER THAN TWO BY FOUR FEET

WEIGHING LESS THAN 56 LBS. SHALL HAVE A #12 GAGE SLACK SAFETYWIRE AT EACH CORNER.

e) ALL LIGHT FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE

INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4) TAUT#12 GAGE HANGER WIRES (ONE AT EACH CORNER) ATTACHED

FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE OROTHER APPROVED HANGERS. THE FOUR (4) TAUT #12 GAGE

WIRES OR OTHER APPROVED HANGERS, INCLUDING THEIRATTACHMENT TO THE STRUCTURE ABOVE, SHALL BE CAPABLE OF

SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE FIXTURE.

2.6.2 SERVICES WITHIN THE CEILING:a) ALL FLEXIBLE SPRINKLER HOSE FITTING MOUNTING BRACKETS,

CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES SHALLBE POSITIVELY ATTACHED TO THE CEILING SUSPENSION

SYSTEMS BY MECHANICAL MEANS TO RESIST A HORIZONTALFORCE EQUAL TO THE WEIGHT OF THE COMPONENT. SCREWS OR

APPROVED FASTENERS ARE REQUIRED. A MINIMUM OF TWO

ATTACHMENTS ARE REQUIRED AT EACH COMPONENT.b) CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES

WEIGHING LESS THAN OR EQUAL TO 20 LB. SHALL HAVE ONE (1)#12 GAGE SLACK SAFETY WIRE ATTACHED FROM THE TERMINAL

OR SERVICE TO THE STRUCTURE ABOVE.c) FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR

TERMINALS OR OTHER SERVICES WEIGHING MORE THAN 20 LB.BUT LESS THAN OR EQUAL TO 56 LB. SHALL HAVE TWO (2) #12

GAGE SLACK SAFETY WIRES (AT DIAGONAL CORNERS)CONNECTED FROM THE TERMINAL OR SERVICE TO THE

STRUCTURE ABOVE.d) FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR

TERMINALS OR OTHER SERVICES WEIGHING MORE THAN 56 LB.

SHALL BE SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BYNOT LESS THAN FOUR (4) TAUT #12 GAGE HANGER WIRES

ATTACHED FROM THE TERMINAL OR SERVICE TO THE STRUCTUREABOVE OR OTHER APPROVED HANGERS. THE FOUR (4) TAUT #12

GAGE WIRES OR OTHER APPROVED HANGERS, INCLUDING THEIRATTACHMENT TO THE STRUCTURE ABOVE, MUST BE CAPABLE OF

SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE UNIT.

2.6.3 OTHER DEVICES WITHIN THE CEILING:

ALL LIGHTWEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBELIGHTS, OCCUPANCY SENSORS, SPEAKERS, EXIT SIGNS, ETC.,

SHALL BE ATTACHED TO THE CEILING GRID PER SECTION 2.6.2 A)OF THIS IR. IN ADDITION, DEVICES WEIGHING MORE THAN 10LBS. SHALL HAVE A #12 GAGE SLACK SAFETY WIRE ANCHORED

TO THE STRUCTURE ABOVE PER SECTION 2.6.1 B) OF THIS IR.DEVICES WEIGHING MORE THAN 20 LBS. SHALL BE SUPPORTED

FROM THE STRUCTURE ABOVE USING DETAILS PROVIDED BY THEREGISTERED DESIGN PROFESSIONAL (RDP).

3. ADDITIONAL REQUIREMENTS:

3.1 PENDANT MOUNTED LIGHT FIXTURES:a) WHERE PENDANT MOUNTED LIGHT FIXTURES ARE TO BE

INSTALLED IN AREAS WITH A SUSPENDED CEILING, THECONSTRUCTION DOCUMENTS SHALL INCLUDE COMPLETE

SUPPORT DETAILS COMPLYING WITH THIS IR AND DSA IR 16-9.b) SUPPORT PENDANT-MOUNTED LIGHT FIXTURES DIRECTLY FROM

THE STRUCTURE ABOVE WITH HANGER WIRES OR CABLESPASSING THROUGH EACH PENDANT HANGER AND CAPABLE OF

SUPPORTING TWO(1) TIMES THE WEIGHT OF THE FIXTURE.

c) IF A PENDANT MOUNTED LIGHT FIXTURE IS DIRECTLY AND

INDEPENDENTLY BRACED BELOW THE CEILING (I.E., AIRCRAFTCABLES TO WALLS), THEN A BRACE ASSEMBLY IS NOT REQUIRED

ABOVE THE CEILING.d) IF A PENDANT MOUNTED LIGHT FIXTURE IS FREE TO SWING 45

DEGREES FROM VERTICAL IN ALL DIRECTIONS, AND IS NOTDIRECTLY AND INDEPENDENTLY BRACED BELOW THE CEILING,

THEN A BRACING ASSEMBLY IS ONLY REQUIRED WHERE THEPENDANT HANGER PENETRATES THE CEILING. SPECIAL DETAILS

ARE REQUIRED TO ATTACH THE PENDANT HANGER TO THEBRACING ASSEMBLY TO TRANSMIT THE HORIZONTAL AND

VERTICAL FORCES. EXCEPTION: WHERE THE WEIGHT OF THEFIXTURE IS LESS THAN 20 POUNDS, THE VERTICAL COMPONENT OF THE BRACE FORCE

NEED NOT BE CONSIDERED SO NO COMPRESSION STRUT/POST

e) RIGID CONDUIT SHALL NOT BE USED FOR ATTACHMENT OF THE

FIXTURES.

3.2 FIRE RATED CEILINGS:a) PROVIDE A DETAIL AND TESTED ASSEMBLY NUMBER FOR RATED CEILING

ASSEMBLIES FROM AN AUTHORIZED TESTING AGENCY. THECOMPONENTS AND INSTALLATION DETAILS MUST CONFORM IN

EVERY RESPECT WITH THE LISTED DETAIL AND NUMBER. DETAILSSHALL CLEARLY DEPICT ALL COMPONENTS, INCLUDING

INSULATION MATERIALS, FRAMING AND ATTACHMENT OF THEDESIGN SO THAT THE ASSEMBLY CAN BE CONSTRUCTED AND

INSPECTED ACCORDINGLY.b) POP RIVETS, SCREWS, OR OTHER ATTACHMENTS ARE NOT

ACCEPTABLE UNLESS SPECIFICALLY DETAILED IN THE DRAWINGS

OR AN APPROVED LISTING BY A STATE FIRE MARSHAL (SFM)

RECOGNIZED LABORATORY.

3.3 ACOUSTICAL CEILING TILE PANEL INSTALLATION

FOR CEILING INSTALLATIONS UTILIZING ACOUSTICAL TILE PANELS OFMINERAL OR GLASS FIBER, IT IS NOT MANDATORY TO PROVIDE ¾"CLEARANCE BETWEEN THE ACOUSTICAL TILE PANELS AND THE WALL ON

THE SIDES OF THE CEILING WHICH ARE FREE TO SLIP.

3.4 OTHER PANEL TYPES:

PANELS WEIGHING MORE THAN ONE-HALF (1/2) PSF, OTHER THANMINERAL FIBER AND GLASS FIBER ACOUSTICAL TILE, AND ALL METALAND WOOD PANELS SHALL BE POSITIVELY ATTACHED TO THE CEILING

SUSPENSION RUNNERS BY MECHANICAL MEANS, SUCH AS BOLTS,SCREWS, OR RIVETS, AND EACH ATTACHMENT SHALL HAVE THE

ALLOWABLE DESIGN STRENGTH TO SUPPORT 100 PERCENT OF THEWEIGHT OF THE PANEL ACTING IN ANY DIRECTION. A MINIMUM OF TWO

ATTACHMENTS ARE REQUIRED FOR EACH PANEL. FOR CEILINGINSTALLATIONS UTILIZING PANELS OTHER THAN MINERAL OR GLASS

FIBER, ¾" CLEARANCE SHALL BE PROVIDED BETWEEN THE CEILINGPANEL AND THE WALL ON THE SIDES OF THE CEILING AREA WHICH ARE

FREE TO SLIP, UNLESS OTHERWISE JUSTIFIED BY SEISMICQUALIFICATION INDICATED BELOW.

THE USE OF OTHER TYPES OF ATTACHMENT, SUCH AS CLIPS, SNAP-INDEVICES, PERFORATED LIPS, CLAMPING DEVICES, OR SPRING LOADED

DEVICES OR HOOKS, SHALL BE LISTED PER DSA IR A-5 AND IDENTIFIEDFOR USE WITH THE TYPE OF CEILING FRAMING MEMBERS AND PANELS.

THE LISTING SHALL BE SEISMICALLY QUALIFIED IN ACCORDANCE WITHASCE 7 SECTION 13.2.5 OR 13.2.6.AN ALTERNATE MEANS OF COMPLIANCE PER CAC 4-304 MAY BE

PROPOSED AND REVIEWED ON A PROJECT BY PROJECT BASIS WHENUSING UNLISTED MEANS OF ATTACHMENT. THE ALTERNATE MEANS

OF ATTACHMENT SHALL HAVE THE ALLOWABLE DESIGN STRENGTHTO SUPPORT 100 PERCENT OF THE WEIGHT OF THE PANEL ACTING

IN ANY DIRECTION AND SHALL BE CAPABLE OF MAINTAINING THATSTRENGTH IF THE CEILING GRID IS DISTORTED OR OUT OF LEVEL.

IT IS ALSO ALTERNATELY PERMITTED TO PROVIDE A SECONDARYMEANS OF CONNECTING THE PANEL TO THE GRID OR STRUCTURE

TO RETAIN THE PANEL IN CASE OF PANEL DROPOUT, CEILING GRIDDISTORTION, AND CEILING GRID BECOMING OUT-OF-LEVEL. THE

SECONDARY ATTACHMENT SHALL HAVE THE ALLOWABLE DESIGNSTRENGTH TO SUPPORT TWO (2) TIMES THE WEIGHT OF THE PANEL

ACTING IN ANY DIRECTION, SUCH AS A SLACK WIRE OR CABLE.SPECIAL ATTACHMENT DETAILS COMPLYING WITH ONE OF THE

METHODS OUTLINED ABOVE, SUCH AS SCREWS OR CABLES, SHALLBE PROVIDED AT THE PERIMETER OF THE CEILING, WHERE PANELSARE CUT OR ALTERED, OR WHERE NON-STANDARD PANEL SIZES OR

EDGE CONDITIONS OCCUR.EXITWAYS: EXITWAYS OF ESSENTIAL SERVICES BUILDINGS SHALL BE

INSTALLED IN ACCORDANCE WITH SECTION13.5.6.2.2 ITEM 1 OF ASCE 7 AS AMENDED BY CBC SECTION

1616A.1.20 (1616.10.16*). A MAIN OR CROSS RUNNER SHALL BEINSTALLED ON ALL SIDES OF EACH PIECE OF TILE, BOARD OR

PANEL AND EACH LIGHT FIXTURE OR GRILL. SPLICES ORINTERSECTION OF SUCH RUNNERS SHALL BE ATTACHED WITH

THROUGH CONNECTORS SUCH AS POP RIVETS, SCREWS, PINS,PLATES WITH END TABS OR OTHER APPROVED CONNECTORS.

3.6 FREE FLOATING CEILINGS:

FREE FLOATING CEILINGS (CEILINGS NOT ATTACHED TO ANYWALLS) SUPPORTED BY WIRES IN ACCORDANCE WITH THIS IR

SHALL BE BRACED IN ACCORDANCE WITH THIS IR, REGARDLESS OFTHE CEILING AREA, UNLESS IT CAN BE DEMONSTRATED THE

ANTICIPATED CEILING MOVEMENT WILL NOT CAUSE FAILURE OFTHE CEILING COMPONENTS OR FAILURE OF MECHANICAL,

ELECTRICAL, PLUMBING, AND FIRE AND LIFE SAFETYCOMPONENTS/SYSTEMS WITHIN THE CEILING AREA AND WITHIN

THE AREA OF ANTICIPATED MOVEMENT.THE PERIMETER OF FREE FLOATING CEILINGS SHALL BE SUPPORTEDBY A CONTINUOUS RUNNER WHICH IS SPLICED IN ACCORDANCE

WITH ASTM E580 SECTION 5.1.2.

4. CEILING SYSTEM ALTERATION: THE ENTIRE CEILING IN THE

AFFECTED SPACE SHALL BE UPGRADED TO MEET THE CURRENTREQUIREMENTS OF THE CBC IF ANY PORTION OF THE GRID SYSTEM IS CUT

OR ALTERED AND THE CEILING HAS NO LATERAL BRACING ASSEMBLIES

(4-WAY SPLAY WIRES AND COMPRESSION POST) OR HAS LATERAL BRACING

ASSEMBLIES SPACED MORE THAN 12 FEET ON-CENTER.

EXEPTION: IF THE CEILING HAS LATERAL BRACING ASSEMBLIES SPACED

NO MORE THAN 12 FEET ON-CENTER, A CEILING UPGRADE WILL ONLY BE

REQUIRED IF THE AREA CUT OR ALTERED EXCEEDS 10 PERCENT OF THE

ENTIRE CEILING AREA.

NOTES:

1. THE "ENTIRE" CEILING IN THE AFFECTED SPACE IS DEFINED AS THE AREA OF

CEILING BOUNDED BY FOUR WALLS OR A COMBINATION OF WALLS AND EXPANSION

JOINTS OR SEISMIC SEPARATION JOINTS.

2. WITH DSA CONCURRENCE, OTHER EXISTING LATERAL BRACING SYSTEMS MAY BE

DEEMED EQUIVALENT TO A 4-WAY SPLAY WIRE AND COMPRESSION POST LATERAL

FORCE BRACING SYSTEM.

4.1 WHERE THE CEILING GRID IS NOT CUT OR ALTERED, AND THE SCOPE OF

WORK INCLUDES ONLY THE FOLLOWING:

• REPLACEMENT OF EXISTING CEILING PANELS WITH LIKE

PANELS OF EQUAL OR LESSER WEIGHT.

• REPLACEMENT OF LIGHT FIXTURES AND/OR TERMINALS WITH

LIKE UNITS (UNITS OF EQUAL SIZE AND OF EQUAL OR LESSER

WEIGHT) PLACED IN THE SAME LOCATION.

NO UPGRADE TO THE CEILING GRID, SUSPENSION SYSTEM OR LATERALFORCE BRACE ASSEMBLIES IS REQUIRED.

4.2 RE-USE OF EXISTING CEILING HANGER WIRES AND BRACING

WIRES: EXISTING CEILING HANGER AND BRACING WIRES MAY BE

REUSED PROVIDED THEY COMPLY WITH THE FOLLOWING:a) THE GAGE AND SPACING OF THE WIRES MUST COMPLY WITH THE

CURRENT APPLICABLE CODES AND THIS IR.b) IF A NEW WIRE IS TO BE SPLICED TO AN EXISTING WIRE, THE

ARCHITECT OR STRUCTURAL ENGINEER IN GENERAL

RESPONSIBLE CHARGE MUST SUBMIT TO THE DSA FOR APPROVALA DETAIL AND SPECIFICATION DESCRIBING HOW THE SPLICE ISTO BE MADE. ACCEPTABLE WIRE SPLICE DETAILS ARE PROVIDED

IN APPENDIX A.c) SEE SECTION 7 FOR TESTING REQUIREMENTS FOR THE RE-USE OF

EXISTING HANGER AND BRACING WIRE ASSEMBLIES.

5. DSA ACCEPTANCE OF EVALUATION REPORTS: CEILING GRID

SYSTEMS OR COMPONENTS, WITH VALID EVALUATION REPORTS ISSUEDBY QUALIFIED EVALUATION AGENCIES, IN ACCORDANCE WITH DSA

IR A-5, ARE ACCEPTED BY THE DSA, PROVIDED THE SYSTEM ORCOMPONENT MEETS THE REQUIREMENTS OF CBC SECTION 1616A.1.20

(1616.10.16*), ASTM C635, C636 AND E580. WHERE A QUALIFIEDEVALUATION REPORT IS UTILIZED, THE INSTALLATION SHALL COMPLYWITH ALL THE REQUIREMENTS SPECIFIED IN THE EVALUATION REPORT,

I.E., CONNECTIONS, MEMBER SIZES, PERIMETER DETAILS, SPECIAL

CLIPS TO WALL ANGLES, ETC.IN ACCORDANCE WITH DSA IR A-5, DSA WILL ACCEPT OSHPD

PREAPPROVED DETAILS (OPD) “2013 CBC STANDARD SUSPENDEDCEILING DETAILS FOR ACOUSTICAL TILE OR LAY-IN PANEL CEILINGS.”

6. TESTING: ALL FIELD TESTING MUST BE PERFORMED IN THE

PRESENCE OF THE PROJECT INSPECTOR OR A SPECIAL INSPECTOR.6.1 NEW INSTALLATIONS:

POST-INSTALLED ANCHORS IN CONCRETE USED TO SUPPORT HANGER

WIRES SHALL BE TESTED AT A FREQUENCY OF 10 PERCENT. POWERACTUATED FASTENERS IN CONCRETE SHALL BE FIELD TESTED FOR 200

LBS. IN TENSION. ALL OTHER POST-INSTALLED ANCHORS IN CONCRETESHALL BE TESTED IN ACCORDANCE WITH CBC SECTION 1913A.7.

POST-INSTALLED ANCHORS IN CONCRETE USED TO ATTACH BRACINGWIRES SHALL BE TESTED AT A FREQUENCY OF 50 PERCENT IN

ACCORDANCE WITH CBC SECTION 1913A.7.

6.2 RE-USE OF EXISTING CEILING HANGER WIRES AND BRACINGWIRES:

a) ALL EXISTING CEILING HANGER WIRE/ANCHOR ASSEMBLIES

MUST BE TESTED TO 200 LBS.b) ALL EXISTING BRACING WIRE/ANCHOR ASSEMBLIES MUST BE

FIELD TESTED TO 440 LBS.c) WHERE A NEW WIRE IS SPLICED TO AN EXISTING WIRE, EACH

SPLICED WIRE/ANCHOR ASSEMBLY MUST BE FIELD TESTED TO

THE LOADS GIVEN FOR EXISTING ASSEMBLIES ABOVE.

REFERENCES:CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24

PART 2, 2016 CALIFORNIA BUILDING CODE (CBC), SECTION1616A.1.21, 1616.10.16* PART 3, 2016 CALIFORNIA ELECTRICAL

CODE (CEC), ARTICLE 410.36ASCE 7-10 MINIMUM DESIGN LOADS FOR BUILDING AND OTHER

STRUCTURES ASTM C635.07, C636-08, AND E580-10A DSA IR 25-2.13

APPENDIX A1. CEILING SYSTEM GENERAL NOTES:

1.1 CEILING SYSTEM COMPONENTS SHALL COMPLY WITH ASTM C635-07 AND

SECTION 5.1 OF ASTM E580-10A.

1.2 THE CEILING GRID SYSTEM MUST BE RATED HEAVY DUTY AS DEFINED BY

ASTM C635-08.

1.3 CEILING SYSTEMS. THE FOLLOWING CEILING SYSTEM(S) IS/ARE PART OF

THE SCOPE OF THIS PROJECT: SEE SPECIFICATIONS SECTION 09 5100 PART 2

MANUFACTURER'S NAME: SEE SPECIFICATIONS SECTION 09 5100 PART 2

PRODUCT EVALUATION REPORT TYPE AND NUMBER: SEE SPECIFICATIONS

SECTION 09 5100 PART 2

.

MANUFACTURER'S MODEL NUMBER - MAIN RUNNER: SEE SPECIFICATIONS

SECTION 09 5100 2.01 B

MANUFACTURER'S CATALOG NUMBER - CROSS RUNNER: SEE SPECIFICATIONS

SECTION 09 5100 2.01 B

.

1.4 SEISMIC WALL CLIP: SEE SPECIFICATIONS

1.5 CEILING PANELS SHALL NOT SUPPORT ANY LIGHT FIXTURES, AIR

TERMINALS OR DEVICES.

1.6 FOR CEILING INSTALLATIONS UTILIZING ACOUSTICAL TILE PANELS OF

MINERAL OR GLASS FIBER, IT IS NOT MANDATORY TO PROVIDE ¾”

CLEARANCE BETWEEN THE ACOUSTICAL TILE PANELS AND THE WALL ON

THE SIDES OF THE CEILING WHICH ARE FREE TO SLIP. FOR ALL OTHER

CEILING PANEL TYPES, PROVIDE ¾” CLEARANCE BETWEEN THE CEILING

PANEL AND THE WALL ON THE SIDES OF THE CEILING FREE TO SLIP.

2. MATERIALS:

2.1 CEILING WIRE SHALL BE CLASS 1 ZINC COATED (GALVANIZED) CARBON

STEEL CONFORMING TO ASTM A641-09A. WIRE SHALL BE #12 GAGE

(0.106” DIAMETER) WITH SOFT TEMPER AND MINIMUM TENSILE

STRENGTH = 70 KSI.

2.2 GALVANIZED SHEET STEEL (INCLUDING THAT USED FOR METAL STUD AND

TRACK COMPRESSION STRUTS/POST) SHALL CONFORM TO ASTM A653-11,

OR OTHER EQUIVALENT SHEET STEEL LISTED IN SECTION A2.1 OF THE

NORTH AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED

STEEL STRUCTURAL MEMBERS 2007, INCLUDING SUPPLEMENT 2 DATED

2010 (AISI S100-07/S2-10). MATERIAL 43 MIL (18 GAGE) AND LIGHTER

SHALL HAVE MINIMUM YIELD STRENGTH OF 33 KSI. MATERIAL 54 MIL (16

GAGE) AND HEAVIER SHALL HAVE A MINIMUM YIELD STRENGTH OF 50 KSI.

2.3 ELECTRICAL METALLIC TUBE (EMT) SHALL BE ANSI C80.3/UL 797 CARBON

STEEL WITH G90 GALVANIZING. EMT SHALL HAVE MINIMUM YIELD STRENGTH

(FY) OF 30 KSI AND MINIMUM ULTIMATE STRENGTH (FU) OF 48 KSI.

ATTACHMENT OF HANGER AND BRACING WIRES:

3.1 SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST SIX (6)

INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC.

3.2 HANGER AND BRACING WIRES SHALL NOT ATTACH TO OR BEND AROUND

OBSTRUCTIONS INCLUDING BUT NOT LIMITED TO: PIPING, DUCTWORK,

CONDUIT AND EQUIPMENT.

3.3 HANGER WIRES THAT ARE MORE THAN ONE (HORIZONTAL) IN SIX

(VERTICAL) OUT OF PLUMB SHALL HAVE COUNTER-SLOPING WIRES.

3.4 SLACK SAFETY WIRES SHALL BE CONSIDERED HANGER WIRES FOR

INSTALLATION AND TESTING REQUIREMENTS.

3.5 HANGER AND BRACING WIRE ANCHORAGE TO THE STRUCTURE SHALL BE

INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHORAGE

ALIGNS CLOSELY WITH THE DIRECTION OF THE WIRE. (E.G. BRACING

WIRE CEILING CLIPS MUST BE BENT AS SHOWN IN THE DETAILS AND

ROTATED AS REQUIRED TO ALIGN CLOSELY WITH THE DIRECTION OF THE

WIRE, SCREW EYES IN WOOD MUST BE INSTALLED SO THEY ALIGN

CLOSELY WITH THE DIRECTION OF THE WIRE, ETC.)

3.

FASTENERS AND WELDING:4.SHEET METAL SCREWS SHALL COMPLY WITH ASTM C1513-10, ASME

B18.6.4-89 (R2005). PENETRATION OF SCREWS THROUGH JOINED

MATERIAL SHALL NOT BE LESS THAN THREE EXPOSED THREADS.

4.1 EXPANSION ANCHORS SHALL BE: AS NOTED ON DETAILS

4.2 POWER-ACTUATED FASTENERS SHALL BE: AS NOTED ON DETAILS

4.3 IF NOT OTHERWISE SPECIFIED IN THE EVALUATION REPORT,

POWER-ACTUATED FASTENERS INSTALLED IN STEEL SHALL BE INSTALLED

SO THE ENTIRE POINTED END OF THE FASTENER IS DRIVEN THROUGH

THE STEEL MEMBER.

4.4 POWER-ACTUATED FASTENERS IN CONCRETE ARE NOT PERMITTED FOR

BRACING WIRES.

4.5 CONCRETE REINFORCEMENT AND PRESTRESSING TENDONS SHALL BE

LOCATED BY NON-DESTRUCTIVE MEANS PRIOR TO INSTALLING POST -

INSTALLED ANCHOR.

4.6 WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 USING E60XX

SERIES ELECTRODES.

5. TESTING: ALL FIELD TESTING MUST BE PERFORMED IN THE PRESENCE

OF THE PROJECT INSPECTOR.

5.1 POST-INSTALLED ANCHORS IN CONCRETE USED TO SUPPORT HANGER

WIRES SHALL BE TESTED AT A FREQUENCY OF 10 PERCENT. POWER

ACTUATED FASTENERS IN CONCRETE SHALL BE FIELD TESTED FOR 200

LBS. IN TENSION. ALL OTHER POST-INSTALLED ANCHORS IN CONCRETE

SHALL BE TESTED IN ACCORDANCE WITH CBC SECTION 1913A.7.

5.02 POST-INSTALLED ANCHORS IN CONCRETE USED TO ATTACH BRACING

WIRES SHALL BE TESTED AT A FREQUENCY OF 50 PERCENT IN ACCORDANCE

WITH CBC SECTION 1913A.7.

6. LIGHT FIXTURES:

6.1 ALL LIGHT FIXTURES SHALL BE POSITIVELY ATTACHED TO THE CEILING

SUSPENSION SYSTEMS BY MECHANICAL MEANS TO RESIST A HORIZONTAL

FORCE EQUAL TO THE WEIGHT OF THE FIXTURE. A MINIMUM OF TWO

SCREWS OR APPROVED FASTENERS ARE REQUIRED AT EACH LIGHT

FIXTURE, PER ASTM E580, SECTION 5.3.1.

6.2 SURFACE-MOUNTED LIGHT FIXTURES SHALL BE ATTACHED TO THE MAIN

RUNNER WITH AT LEAST TWO POSITIVE CLAMPING DEVICES. THE CLAMPING

DEVICE SHALL COMPLETELY SURROUND THE SUPPORTING CEILING RUNNER AND

BE MADE OF STEEL WITH A MINIMUM THICKNESS OF #14 GAGE. ROTATIONAL

SPRING CATCHES DO NOT COMPLY. A #12 GAGE SLACK SAFETY WIRE SHALL BE

CONNECTED FROM EACH CLAMPING DEVICE TO THE STRUCTURE ABOVE.

PROVIDE ADDITIONAL SUPPORTS WHEN LIGHT FIXTURES ARE EIGHT (8) FEET

OR LONGER OR EXCEED 56 LB. MAXIMUM SPACING BETWEEN SUPPORTS SHALL

NOT EXCEED EIGHT (8) FEET.

6.3 LIGHT FIXTURES WEIGHING LESS THAN OR EQUAL TO 10 LB. SHALL HAVE A

MINIMUM OF ONE (1) #12 GAGE SLACK SAFETY WIRE CONNECTED FROM THE

FIXTURE HOUSING TO THE STRUCTURE ABOVE.

6.4 LIGHT FIXTURES WEIGHING GREATER THAN 10 LB. BUT LESS THAN OR EQUAL

TO 56 LBS. MAY BE SUPPORTED DIRECTLY ON THE CEILING RUNNERS, BUT THEY

SHALL HAVE A MINIMUM OF TWO (2) #12 GAGE SLACK SAFETY WIRES

CONNECTED FROM THE FIXTURE HOUSING AT DIAGONAL CORNERS TO THE

STRUCTURE ABOVE.

EXCEPTION: ALL LIGHT FIXTURES GREATER THAN TWO BY FOUR FEET

WEIGHING LESS THAN 56 LBS. SHALL HAVE A #12 GAGE SLACK SAFETY

WIRE AT EACH CORNER.

6.5 ALL LIGHT FIXTURES WEIGHING GREATER THAN 56 LB. SHALL BE

INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR (4) TAUT #12

GAGE HANGER WIRES (ONE AT EACH CORNER) ATTACHED FROM THE

FIXTURE HOUSING TO THE STRUCTURE ABOVE OR OTHER APPROVED

HANGERS. THE FOUR (4) TAUT #12 GAGE WIRES OR OTHER APPROVED

HANGERS, INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE,

SHALL BE CAPABLE OF SUPPORTING FOUR (4) TIMES THE WEIGHT OF THE

FIXTURE.

7. SERVICES WITHIN THE CEILING:

7.1 ALL FLEXIBLE SPRINKLER HOSE FITTING MOUNTING BRACKETS,

CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES SHALL BE

POSITIVELY ATTACHED TO THE CEILING SUSPENSION SYSTEMS BY

MECHANICAL MEANS. SCREWS OR APPROVED FASTENERS ARE REQUIRED.

A MINIMUM OF TWO ATTACHMENTS ARE REQUIRED AT EACH COMPONENT.

7.2 CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES WEIGHING LESS

THAN OR EQUAL TO 20 LB. SHALL HAVE ONE (1) #12 GAGE SLACK

SAFETY WIRE ATTACHED FROM THE TERMINAL OR SERVICE TO THE

STRUCTURE ABOVE.

7.3 FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR TERMINALS

OR OTHER SERVICES WEIGHING MORE THAN 20 LB. BUT LESS THAN OR

EQUAL TO 56 LB. SHALL HAVE TWO (2) #12 GAGE SLACK SAFETY WIRES

(AT DIAGONAL CORNERS) CONNECTED FROM THE TERMINAL OR SERVICE

TO THE STRUCTURE ABOVE.

7.4 FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR TERMINALS

OR OTHER SERVICES WEIGHING MORE THAN 56 LB. SHALL BE SUPPORTED

DIRECTLY FROM THE STRUCTURE ABOVE BY NOT LESS THAN FOUR (4) TAUT #12

GAGE HANGER WIRES ATTACHED FROM THE TERMINAL OR SERVICE TO THE

STRUCTURE ABOVE OR OTHER APPROVED HANGERS.

8. OTHER DEVICES WITHIN THE CEILING:

8.01 ALL LIGHTWEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBE LIGHTS,

OCCUPANCY SENSORS, SPEAKERS, EXIT SIGNS, ETC., SHALL BE ATTACHED TO

THE CEILING GRID. IN ADDITION, DEVICES WEIGHING MORE THAN 10 LBS.

SHALL HAVE A #12 GAGE SLACK SAFETY WIRE ANCHORED TO THE STRUCTURE

ABOVE. DEVICES WEIGHING MORE THAN 20 LB. SHALL BE SUPPORTED

INDEPENDENTLY FROM THE STRUCTURE ABOVE.

ICC-ES REPORT ESR-1308 (VALID UNTIL 12/19)

IS REQUIRED.

3.5

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

westbergwhitearchitecture

PDW

TC

D

D

LU

A

RA

NEC

BE

RG

SN WES

TIL

ES

ETIHC

ATA

T

EOF

S

I

C-11045EXP.9-2021

NE

P

CA L I FO

RN

I

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:24 PM

A850

CEILING NOTES

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

FREE JOINT

ATTACHED

JOINT

CROSS RUNNERS TYP.

BRACING WIRELOCATION-TYP.

CONT ANGLE @ PERIMETER

NOTE:

BRACING WIRES AND COMP. STRUT SHALL OCCURAT EVERY 144 SQ. FT. MAX. IN ROOMS OVER 144 SQ. FT.

MAIN RUNNERS

STABILIZER BARS,

CROSS TEES OR

STRUTS 8" MAX. FROM WALL TYP. ALONG

FREE JOINTS

MAX

6' - 0"

MAX

12' - 0"

MAX

6' - 0"

MAX

6' -

0"

MAX

12' -

0"

MAX

6' -

0"

2.60

2.60

ATTACHED

JOINT

FREE JOINT

2.60 FREE

JOINT

2.60ATTACHED

JOINT

144 SQ

FT MAX

TYPICAL2.35

1.

REFER TO DETAIL 3.21/A851 FOR MAX. STRUT SPACING AND IR 25-2.132.

3.10

4.10

STRUTS SHALL NOT REPLACE HANGER WIRES.

THE MINIMUM ACCEPTABLE ANGLE IS DETERMINED SUCH THAT THE WIRES DO

NOT INTERFER WITH THE RUNNERS, LIGHT FIXTURES, ETC. AND REMAIN STRAIGHT AND UNOBSTRUCTED.

NOTES:

RIGID VERT. STRUT

SEE DET.

4.10

12 GA VERTICAL HANGERS AT

4'-0" O.C. EACH WAY AT MAIN RUNNER

WITH MINIMUM 3-TIGHT TURNS IN 3"

AT BOTH ENDS, SEE

12 GA. BRACING WIRE W/MIN. 4-

TIGHT TURNS IN 1 1/2" BOTH ENDS

OF WIRE CONNECTED TO MAIN RUNNERS 90º APART, 4-TOTAL AT

EACH STRUT (U.N.O.) SEE

SEE DETAIL 3.10 FOR

LOCATION OF BRACING

WIRES AND STRUT

MAIN RUNNER

CROSS RUNNER

1.

.

6 MIN

1

0° TO 45°

(NOTE 2)

2'-0" TYP

4'-0"

2'-0" TYP

2.

ATTACHED JOINT FREE JOINT

NOTES:

1. PROVIDE #12 GAGE HANGER WIRES AT THE ENDS OF

ALL MAIN AND CROSS RUNNERS WITHIN EIGHT

(8) INCHES OF THE SUPPORT OR WITHIN ONE-FOURTH

(1/4) OF THE LENGTH OF THE END TEE, WHICHEVER IS LESS, FOR THE PERIMETER OF THE CEILING AREA.

PERIMETER WIRES ARE NOT REQUIRED WHEN THE

LENGTH OF THE END TEE IS EIGHT (8) INCHES OR

LESS.

CONT. SLOTTED ANGLE STABILIZER BAR W/ HORIZ. 6d RINGSHANK NAIL

(NOTE 2). OMIT STRUT WHERE RUNNER IS WITHIN 8" OF WALL .

ALTERNATE STABILIZER LOCATION

W/O NAIL (NOTE 5)

HANGER WIRE

MAIN OR CROSS

RUNNER

CEILING

PANEL

STEEL POP RIVET @

ATTACHED SIDE ONLY

CHANNEL.

(STABILIZER BAR)

RUNNER

(SEE NOTE 1 BELOW)

8" MAX.

(SEE NOTE 1 BELOW)

8" MAX.

2. NAILS AT ENDS OF HORIZONTAL STABILIZERS

ARE TO BE PLACED WITH NAIL HEAD TOWARD

CENTER LINE OF SPAN OF STRUT.

3/4" MIN. CLR.

3.

APPROVED STABILIZER

1" x 2" x 25 GA. MIN. CONTINUOUS ANGLE WITH (1) #10 SMS INTO 20 GA.

MIN. WALL STUD @ 24" O.C.

(TYP.)

1/2

" M

IN.

(SEE NOTE 3)

NOTE #4

STABILIZER BAR MAY BE SLOTTED APPROVED ANGLES OR

CHANNELS WITH "DIAMOND POINTS" OF SPRING STEEL WHICH

SNAP TIGHT TO PREVENT MOVEMENT OF STRUT.

3.

(1) #10 SMS TO 20 GA. MIN. WALL STUD @ 24" O.C.4.

1"

2"

AIR TERMINAL OR

LIGHT FIXTURE

(56# MAX.)

(2) 12 GA. SLACK SAFETY WIRE HANGERS

FOR DEVICES THAT WEIGH LESS THAN 56

LBS PLACE ON DIAGONAL CORNERS.

EXCEPTION: FIXTURES GREATER THAN 2 FEET X 4 FEET WEIGHING LESS THAN 56

LBS. REQUIRE A 12 GA. SLACK SAFETY WIRE

HANGER AT EA. CORNER.

1-#8 S.M.S. IN OPPOSITE SIDES (2

TOTAL) LOCATE SCREWS NEAR THE

CENTER OF TERMINAL OR FIXTURE

HEAVY DUTY SYSTEM

5.10

4.10

FOR CONNECTION TOSTRUCTURE SEE

STRUCTURE

BRACE WIRES

SEE

(2) 1/4"DIA. MACHINE

BOLT

CROSS RUNNER

MAIN RUNNER

3/4" MIN. EDGE

DISTANCE,TYP.

HANGER WIRE

4 TIGHT TURNS IN 1

1/2" TYP. FOR

BRACE WIRE

3 TIGHT TURNS

IN 3" FOR

HANGER TYP.

MAX

1 1/2"

TY

P0º T

O 4

.

.

CHANNEL TYPE

COMPRESSION STRUT

PER TABLE 0N 3.21 CENTERED OVER CROSS

RUNNER

MAX

1 1/2"

MAX

4'-0" OC

TYP

3/4" MIN 1" MAX

A

NO

T T

O E

XCEED

TH

E A

LLO

WABLE

LEN

GTH

GIV

EN

IN

TH

E T

ABLE

ON

3.2

1 F

OR

TH

E C

OM

PR

ESSIO

N S

TR

UT S

ELE

CTED

MAIN RUNNER

CROSS RUNNER

BRACE WIRE BEYOND

HANGER WIRE

BEYOND

COPE FLANGE OR FLATTEN TO

ALLOW INSTALLATION OF

ACOUSTICAL TILE

CHANNEL COMPRESSION STRUT MAXIMUM LENGTH

250S125-33

250S137-33

362S137-33

250137-43

400S137-43

5'-0"

6'-10"

8'-0"

8'10"

10'-10"

NOTES:

1. REFER TO 4.10 FOR ADDITIONAL DETAILS.2. POST INSTALLED ANCHORS TO BE PLACED NO MORE THAN 1" OFFSET FROM CENTERLINE OF DECK LOW FLUTE

3. TEST POST INSTALLED ANCHORS IN ACCORDANCE WITH CEILING NOTE 5.01.

L BOLT & FLUTE (SEE NOTE 3)

LIGHTWEIGHT OR

NORMAL

WEIGHT

CONCRETE

12GA x 1" WIDE

CEILING CLIP MIN.

3/8" DIA. HILTI KB-TZ (ICC ESR-

1917). 2" MIN. EMBED.

OPTION 1

4.10

1/2" MAX. STEEL DECK,

20GA MIN.

METAL DECK (20 GA MIN.)

HILTI X-CR (0.145" DIA.) SHOT PIN (ICC ESR-1663) 1-1/4" MIN. EMBED.

L 1-1/2"x 1-1/2"x 12 GA

4.10

LIGHTWEIGHT OR

NORMAL WEIGHT

CONCRETE

12GAx3/4" WIDE

CEILING CLIP

4.10

3/4" MIN

HILTI X-CR (0.145" DIA.) SHOT PIN (ICC ESR-1663) 1-1/4" MIN. EMBED.

OPTION 2

OPTION 3

C

4.11

4.11

3 TURNS @ HANGER WIRE TYPICAL

@ EACH END

4 TURNS @ BRACE WIRES TYP.

@ EACH END

FOR CONNECTION TO

STRUCTURE SEE CONNECTION

MATRIX ON

FOR CONNECTION TO

STRUCTURE SEE CONNECTION

MATRIX ON

HANGER WIRE

BRACING WIRE

1 1/2" MAX.

10° TO 45°

3"

MAX.

1/2" MAX. U.O.N.

#12 GAGE WIRE

#12 GAGE WIRE

1/2

" TYP

1/2" TYP

U.N.O.

1/2" MAX

362S137-33 MIN. BACKING STUD. SPAN 2

WALL STUDS MINIMUM. FASTEN BACKING

TO WALL STUDS USING (2) #10X1-1/4"

SMS AT EACH STUD.

1"x1"x12GAx3/4" CLIP ANGLE. FASTEN TO

BACKING STUD USING #10 X 1-1/4"

SHEET METAL SCREW.

4.10

NOTES:

1. THIS IS APPLIED FOR PERIMETER

WIRE ATTACHEMENT OR WHERE OBSTRUCTION PREVENTS

ATTACHMENT TO STRUCTURE

ABOVE

1

6 MIN.

1

6

1"x1"x12GAx3" CLIP

ANGLE

2-#10 S.M.S. @

2" O.C.

WALL STUD PER RDP

20 GA MIN

1 LAYER OF GYP. BD.

4.10

WALL STUD PER

RDP 20 GA MIN

GYP. BD.

(2) #10 SMS

TO FRAMING

1"x1"x12GAx3/4"

CLIP ANGLE

4.10

A. "DIRECT"

(FOR NOTES SEE

"B"

"THRU GYP.)

B. "THRU GYP" 1

OPTION 1 OPTION 2

OPTION 3

(1) #10 SMS

6 MIN.

L1-1/2"x 1-1/2"x 12

GA x 0'-2" CLIP

STRUCTURAL STEEL

HANGER WIRE

NOTES :

1. BEAM FLANGE THICKNESS SHALL NOT BE LESS THAN 3/16".

2. RDP IN RESPONSIBLE CHARGE, IOR AND CONTRACTOR SHALL VERIFY THAT NO PAF IS INSTALLED IN THE PROTECTED ZONE OF ANY STEEL MEMBER. SEE ANSI/AISC 341-10

3. REFER TO 4.10 FOR ADDITIONAL DETAILS

1/2" MAX

HILTI X-U

(0.157" DIA.)

SHOT PIN (ICC

ESR-2269)

STRUCTURAL CONDITION

OF FLOOR/ ROOF ABOVE

SUSPENDED CEILING

METAL DECK

CONCRETE OVERMETAL DECK

CONCRETE SLAB, BEAM,OR JOIST

STRUCTURAL STEEL

METAL STUD WALL

SAWN TIMBER

WOOD I JOIST

WOOD CHORD TRUSS

OPEN WEB STEEL JOIST

APPLICABLE

HANGER WIREDETAIL

4.20

4.21

4.22

4.23

4.24

4.25, 4.29

4.26

4.27, 4.29

4.28, 4.29

APPLICABLE

BRACING WIRE

DETAIL

4.30

4.31

4.32

4.33

4.34

4.35

4.36, 4.37

4.38, 4.29

4.39, 4.29

NOTES:

1. IF SELF-TAPPING SCREWS ARE USED WITH CONCRETE FILL,

SET SCREWS BEFORE PLACING CONCRETE.

METAL DECK (20 GA MIN.)

(2) #8 x 1/2" SELF-

TAPPING SCREWS

STEEL STRAP 3" WIDE

x 4" LONG x 12 GA. MIN., BEND

TO ALIGN WITH WIRE

INSULATION OVER

METAL DECK

BRACING WIRE

4.10

MIN 5/8" DIA. HILTI KB-TZ (ICC

ESR-1917). 4" MIN. EMBED.

NOTES:

1. TEST POST INSTALLED ANCHORS IN ACCORDANCE WITH CEILING NOTE 5.02

2. REFER TO 4.10 FOR ADDITIONAL DETAILS3. POST INSTALLED ANCHORS TO BE PLACED NO MORE THAN 1" OFFSET FROM CENTERLINE OF

DECK LOW FLUTE.

1 1/2"x 1 1/2"x12GA x2" CEILING

CLIP, TYP

LIGHTWEIGHT OR NORMAL WEIGHT

CONCRETE

4.10

TYP

3/4" MIN

(2) 3/8" DIA HILTI KB-TZ (ICC ESR-1917).

2" MIN. EMBED.

LIGHTWEIGHT OR NORMAL

WEIGHT CONCRETE

OPTION 1

OPTION 2

1-1/2"x1-1/2"x12GA

4.10

1/2" MAX.

(3) HILTI X-U (0.157" DIA.) SHOT PIN (ICC ESR-2269)

BRACING WIRE

NOTES :

1. BEAM FLANGE THICKNESS SHALL NOT BE LESS THAN 3/16".

2. RDP IN RESPONSIBLE CHARGE, IOR, AND CONTRACTOR SHALL VERIFY THAT NO PAF IS INSTALLED IN THE PROTECTED ZONE OF ANY STEEL MEMBER. SEE ANSI/AISC 341-10

3. REFER TO 4.10 FOR ADDITIONAL DETAILS

1/2" MAX.

2" X 2" X 2" LONG X 12 GA. CLIP

METAL STUD PER RDP

MIN 18 GA

1 LAYER OF GYP. BD., MAX.

600S137-54 SPAN (2) WALL STUDS

MINIMUM USING

(4) #10 x 1-1/4" SMS AT EA STUD,

(ONLY (2) #10 SMS REQUIRED WHERE CLIP ATTACHES DIRECTLY TO WALL

STUD)

1-1/2"x1-1/2"x12GAx1" CLIP ANGLE W/ (2)

#10x1-1/4" SMS

1/2

" M

AX

4.10

STRUCTURAL CONDITION

OF FLOOR / ROOF ABOVE

COMPRESSION STRUT

APPLICABLE

DETAIL

METAL DECK

CONCRETE OVER

METAL DECK

CONCRETE SLAB, BEAM,

OR JOIST

STRUCTURAL STEEL

SAWN TIMBER WITH

GYPSUM BOARD

SAWN TIMBER WITHOUT

GYPSUM BOARD

5.20

5.21

5.30

5.40

5.50

5.60

LIGHTWEIGHT

OR NORMAL

WEIGHT CONCRETE

3/8" DIA. HILTI KB-TZ

(ICC ESR-1917). 2" MIN.

EMBED @ CENTER

OF FLUTE

CUT FLANGES

AND BEND

CHANNEL STRUT

3 7/8" MIN.

2"

1"

(2) #10 S.M.S L 1-1/2 x 1-1/2 x 12 GA.

3/4" MIN

OPTION 1 OPTION 2

3/8" DIA. HILTI KB-TZ (ICC ESR-

1917). 2" MIN. EMBED.

NOTES:

1. POST INSTALLED ANCHORS TO BE PLACED NO MORE THAN 1" OFFSET FROM CENTERLINE OF DECK LOW FLUTE

2. TEST POST INSTALLED ANCHORS IN ACCORDACE WITH CEILING NOTE 5.01

2"CUT FLANGES

AND BEND

(2) HILTI X-U (0.157" DIA.) SHOT PIN (ICC ESR-2269)

NOTES:

1. STRUCTURAL STEEL MEMBER SHALL NOT BE LESS THAN 3/16".

2. RDP IN RESPONSIBLE CHARGE, I.O.R. AND CONTRACTOR SHALL VERIFY THAT NO PAF IS

INSTALLED IN THE PROTECTED ZONE OF ANY STEEL MEMBER, SEE ANSI/AISC 341-10.

3. REFER TO 5.20 AND 5.30 FOR ADDITIONAL INFORMATION.

3 TURNS IN 3" TYPICAL

@ EACH END

HANGER WIRE ONLY

HANGER WIRE

4 TURNS IN 1-1/2" TYPICAL

@ EACH END

HANGER OR BRACE WIRE

BRACE OR HANGER

WIRE

NOTES:

WIRE SPLICES ARE SHOWN LOOSELY TIED FOR ILLUSTRATIVE PURPOSES ONLY

AND SHALL BE DRAWN TIGHT TO COMPLETE INSTALLATION WHEN CONSTRUCTED.

CHANNEL STRUT

(2) #10 S.M.S

L 2" x 2" x 12 GA.

3/4" MIN

OPTION 1 OPTION 2

#12 S.M.S

(2) #12 S.M.S.(2) #10 S.M.S

L 2" x 2" x 12 GA.

x 0'-8"

INSULATION OVER METAL DECK

METAL DECK

(20 GA. MIN.)

DS

A A

PP

RO

VA

L P

LA

NS

SHEET NO:

SHEET DESCRIPTION:

JOB NO:

CLIENT:

PROJECT NAME:

DATE:

DRAWN:

CHECK:

ARCHITECT:

ENGINEER:

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

Rev. Date DescriptionNo.

westbergwhitearchitecture

PDW

TC

D

D

LU

A

RA

NEC

BE

RG

SN WES

TIL

ES

ETIHC

ATA

T

EOF

S

I

C-11045EXP.9-2021

NE

P

CA L I FO

RN

I

STATE:

ARCHITECT:

CONSULTANT:

C:\Users\emercado\Documents\c20030-Master_emercado.rvt1/21/2021 3:47:26 PM

A851

CEILING DETAILS

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fullert

on C

ollege

JG

EM

01/21/2021

20030

BLD

G 1

000 I

MPRO

VEM

EN

TS

321 E

Chapm

an A

ve

Fullert

on C

a.

92832

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1/8" = 1'-0" 2.12TYP. 12'-0"X12'-0" CEILING PLAN

3" = 1'-0" 2.35SUSPENSION & BRACING ASSEMBLY

3" = 1'-0" 2.6CEILING PERIMETER

3" = 1'-0" 2.8LIGHT FIXT/AIR TERMINAL SUPPORT

1 1/2" = 1'-0" 3.10ACT - CHANNEL TYPE STRUT

1 1/2" = 1'-0" 3.21COMPRESSION STRUT TABLE

1 : 10 4.21HGR WIRE CONN TO CONC OVER MTL DECK

3" = 1'-0" 4.10TYP. WIRE TURNS

3" = 1'-0" 4.24HGR WIRE CONN TO METAL STUD WALL

1 1/2" = 1'-0" 4.23HGR WIRE CONN TO STRUCT STEEL

1" = 1'-0" 4.11COMPRESSION STRUT TABLE

1 : 10 4.30BRACING WIRE CONN AT METAL DECK

1 : 10 4.31CONN TO CONC OVER METAL DECK

1 1/2" = 1'-0" 4.33BRACING WIRE CONN TO STRUCT STL 3" = 1'-0" 4.34CONN TO METAL STUD WALL

1 1/2" = 1'-0" 5.10COMPRESSION STRUT TABLE

1 1/2" = 1'-0" 5.21STRUT CONN TO CONC OVER MTL DECK

1 1/2" = 1'-0" 5.40STRUT CONN TO STRUCTURAL STEEL

3" = 1'-0" 6.10CEILING WIRE SPLICES

1 1/2" = 1'-0" 5.20STRUT CONN TO METAL DECK

SYMBOL LIST, NOTES,SHEET INDEX ANDDETAILS

LIGHT FIXTURE SCHEDULE FBA #

TYPE LIGHT FIXTURE DESCRIPTION

FIXT

UR

E M

AXIM

UM

TOTA

L IN

PUT

WAT

TS

FIXT

UR

E M

INIM

UM

LUM

EN O

UTP

UT

EFFI

CIE

NC

Y

FIXTURE MOUNTING

LAM

P TY

PE

LAM

P C

OLO

RTE

MPE

RAT

UR

E K°

LAM

P C

RI,

NO

T LE

SSTH

AN

EAC

H L

AMP

INIT

IAL

MIN

IMU

M L

UM

ENO

UTP

UT

TOTA

L AL

L LA

MPS

INIT

IAL

MIN

IMU

MLU

MEN

OU

TPU

T

LAM

P Q

UAN

TITY

A1

2' X 4' RECESSED MOUNTED LED TROFFER, 4700 LUMENS, 35K,UNIVERSAL 0-10V DIMMING DRIVER.

FINELITE HPR LED SERIES#HPR LED-A-2X4-DCO-B-835-UNV-SC OR EQUAL

35 4742 RECESSED LED 35K 4742

A1EM

2' X 4' RECESSED MOUNTED LED TROFFER, 4700 LUMENS, 35K,UNIVERSAL 0-10V DIMMING DRIVER, 90 MINUTE EMERGENCYBATTERY PACK.

FINELITE HPR LED SERIES#HPR LED-A-2X4-DCO-S-835-UNV-SC-EM OR EQUAL

35 4742 RECESSED LED 35K 4742

X1

LED EXIT SIGN, DIE CAST ALUMINUM HOUSING IN WHITE FINISH,RED LETTERS, CEILING OR WALL MOUNT, BATTERY PACK FOR90 MINUTES OF EMERGENCY ILLUMINATION.

ISOLITE ELT SERIES #ELT-FT-EM-1C-BA-RC OR EQUAL

3 CEILING OR WALL LED

GENERAL NOTES1. THESE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER A COMPLETE INSTALLATION OF SYSTEMS. THE OMISSION OR EXPRESSED REFERENCE TO ANY ITEM OF LABOR OR MATERIALS REQUIRED FOR THE PROPER EXECUTION OF THE WORK IN ACCORDANCE WITH PRESENT PRACTICE OF THE TRADE SHALL NOT RELIEVE THE CONTRACTOR FROM PROVIDING SUCH ADDITIONAL LABOR AND MATERIALS.

2. THIS PROJECT IS A RENOVATION OF EXISTING RESTROOMS INAN EXISTING BUILDING ON AN EXISTING COLLEGE CAMPUS SITE.REFER TO THE ARCHITECTURAL DRAWINGS FOR NOTES ANDOTHER ELECTRICAL REQUIREMENTS NOT SHOWN ON THEELECTRICAL DRAWINGS AND TO DETERMINE EXISTINGCONSTRUCTION TO REMAIN AS WELL AS NEW CONSTRUCTION.IF THERE ARE OMISSIONS OR CONFLICTS BETWEEN THEELECTRICAL DOCUMENTS AND THE DOCUMENTS OF OTHERTRADES, CLARIFY THESE POINTS WITH THE ARCHITECT BEFORESUBMITTING A BID. NO EXTRA PAYMENT WILL BE ALLOWED FORFAILURE TO OBTAIN THIS INFORMATION.

3. THESE PLANS, SPECIFICATIONS, AND ALL MATERIALS SHALL BE IN FULL ACCORDANCE WITH ALL LEGAL AND INDUSTRY REQUIREMENTS, AND STANDARDS INCLUDING WITHOUT LIMITATION TO THE FOLLOWING:

a. CALIFORNIA CODE OF REGULATIONS TITLE 24, PARTS 1 AND 2 (CALIFORNIA BUILDING CODE), 2019 EDITION.

b. CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 3 (CALIFORNIA ELECTRICAL CODE), 2019 EDITION.

c. CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 6 (CALIFORNIA ENERGY CODE), 2019 EDITION.

d. CALIFORNIA CODE OF REGULATIONS TITLE 24, PART 9 (CALIFORNIA FIRE CODE), 2019 EDITION.

e. OTHER REGULATING AGENCIES WHICH MAY HAVE AUTHORITY OVER ANY PORTION OF THE WORK, INCLUDING THE STATE OF CALIFORNIA DIVISION OF INDUSTRIAL SAFETY, AND THOSE CODES AND STANDARDS LISTED IN THESE NOTES AND SPECIFICATIONS.

f. THE ELECTRICAL SYSTEMS FUNCTIONALITY STANDARDS SET FORTH IN TITLE 7 OF THE CALIFORNIA CIVIL CODE (THE "RIGHT TO REPAIR ACT").

g. THE MANUFACTURER'S REQUIREMENTS OR RECOMMEND- ATIONS FOR ANY INCORPORATED PRODUCTS.

h. THE MOST CURRENT APPROVED ISSUES OF ANY NOTED SPECIFICATIONS, CODES AND STANDARDS, INCLUDING SUPPLEMENTS, UNLESS NOTED OTHERWISE.

4. THE PLANS REPRESENT ONLY THE FINISHED ELECTRICAL, FIRE ALARM, AND LOW VOLTAGE SYSTEMS, AND THEY ARE NOT INTENDED TO INDICATE OR REQUIRE ANY CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES.

5. IN USING THE PLANS FOR BIDDING OR CONSTRUCTION PURPOSES, THE CONTRACTOR IS REQUIRED TO REVIEW ALL OF THE PROJECT'S CONSTRUCTION DOCUMENTS AS A WHOLE IN ORDER TO IDENTIFY ALL REQUIREMENTS THAT DIRECTLY OR INDIRECTLY AFFECT ITS PORTION OF THE ELECTRICAL WORK, EVEN REQUIREMENTS LOCATED IN SECTIONS DESIGNATED AS APPLICABLE TO OTHER TRADES. IN CASE OF CONFLICTS, THE CONTRACTOR SHALL EITHER OBTAIN DIRECTION FROM AN APPROPRIATE OWNER REPRESENTATIVE OR OTHERWISE APPLY THE MORE STRINGENT REQUIREMENT.

6. IN INTERPRETATING THE PLANS, THE FOLLOWING GENERAL RULES APPLY:

a. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DRAWINGS.

b. SCALED DIMENSIONS AND GRAPHICALLY SHOWN LOCATIONS ARE TO BE CONSIDERED ONLY APPROXIMATE. FIELD VERIFY DIMENSIONS PRIOR TO BID.

7. IN IMPLEMENTING THE PLANS, THE FOLLOWING GENERAL RULES APPLY:

a. BECAUSE THE PLANS ARE INTENDED TO SET FORTH THE REQUIREMENTS FOR CONSTRUCTION IN ONLY AN INDUSTRY-STANDARD LEVEL OF QUALITY AND DETAIL, AND THEREFORE ARE INTENDED TO BE SUPPLEMENTED BY APPROPRIATE REQUESTS FOR CLARIFICATION AND INFORMATION, ERRORS AND OMISSIONS ARE TO BE EXPECTED AND ANTICIPATED; AND THE CONT- RACTOR IS REQUIRED TO CAREFULLY REVIEW THE PLANS FOR ERRORS AND OMISSIONS AND TO BRING THESE ERRORS AND OMISSIONS TO THE ATTENTION OF AN APPROPRIATE OWNER REPRESENTATIVE IN A TIMELY MANNER AN ASSUMES THE RISK OF THE CONSEQUENCES OF FAILING TO DO SO BEFORE BIDDING OR OTHERWISE PROCEEDING.

b. THE CONTRACTOR SHALL REVIEW AND VERIFY ALL DIMENSIONS PRIOR TO STARTING CONSTRUCTION, AND NOTIFY THE ARCHITECT IMMEDIATELY OF ANY DISCRE- PANCIES OR INCONSISTENCIES..

8. SUBMITTALS WILL BE REVIEWED BY THE ELECTRICAL ENGINEER, IF AT ALL, ONLY PURSUANT TO THE INDUSTRY- STANDARD PROTOCOL SET FORTH IN A1A DOCUMENT A201, AND IN NO EVENT WILL THE SUBMITTAL REVIEW PROCESS RELIEVE OR LESSEN THE SUBMITTING CONTRACTOR'S RESPONSIBILITY FOR AN INAPPROPRIATE SUBMITTAL.

9. IN NO EVENT WILL ANY SITE VISITS BY THE ELECTRICAL ENGINEER CONCERN CONSTRUCTION MEANS AND METHODS OR CONSTRUCTION SAFETY, AND ALL SUCH MATTERS SHALL REMAIN THE SOLE RESPONSIBILITY OF THE CONTRACTOR.

10. COPIES OF THE PLANS PROVIDED IN ANY ELECTRONIC FORM ARE SUBJECT TO THE SAME PROVISIONS AS THE OTHER INSTRUMENTS OF SERVICE PREPARED BY OR ON BEHALF OF ELECTRICAL ENGINEER FOR THE PROJECT, INCLUDING WITHOUT LIMITATION THE ENGINEER'S COMMON LAW, STATUTORY OR OTHER RESERVED RIGHTS, INCLUDING COPYRIGHTS. A RECIPIENT IS GRANTED AT MOST A TRANSFERABLE NONEXCLUSIVE LICENSE TO REUSE THE PLANS SOLELY FOR PROJECT PURPOSES; AND NO RECIPIENT IS AUTHORIZED TO USE OR TO ALLOW THE USE OF ALL OR ANY PORTION OF THESE PLANS FOR ANY OTHER PURPOSE, AND ANY USE FOR ANY OTHER PURPOSE WOULD CONSTITUTE ACTIONABLE PLAGIARISM. ELECTRICAL ENGINEER PROVIDES DOCUMENTS IN AN ELECTRONIC FORM ONLY IN ITS STANDARD FORMATS AND CONVENTIONS AND WITH NO GUARANTEE OF COMPATIBILITY WITH ANY RECIPIENT'S SOFTWARE OR HARDWARE, AND ANY USE WITH OR CONVERSION TO OTHER FORMATS OR CONVENTIONS, OR THE USE WITH ANY PARTICULAR SOFTWARE OR HARDWARE, IS AT THE RECIPIENT'S SOLE RISK.

11. REFER TO THE DRAWINGS AND SHOP DRAWINGS OF OTHER TRADES FOR ADDITIONAL DETAILS WHICH AFFECT THE PROPER INSTALLATION OF THIS WORK.

12. BEFORE SUBMITTING A BID, THE CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH ALL FEATURES OF THE EXISTING BUILDING, AND ALL BUILDING DRAWINGS WHICH MAY AFFECT THE EXECUTION OF THE WORK. NO EXTRA PAYMENT WILL BE ALLOWED FOR FAILURE TO OBTAIN THIS INFORMATION.

13. PROTECT ALL WORK, MATERIALS AND EQUIPMENT FROM DAMAGE FROM ANY CAUSE WHATEVER AND PROVIDE ADEQUATE AND PROPER STORAGE FACILITIES DURING THE PROGRESS OF THE WORK. PROVIDE FOR THE SAFETY AND GOOD CONDITION OF ALL THE WORK UNTIL FINAL ACCEPTANCE OF THE WORK BY THE OWNER AND REPLACE ALL DAMAGED OR DEFECTIVE WORK, MATERIALS AND EQUIPMENT BEFORE REQUESTING FINAL ACCEPTANCE.

14. THE DRAWINGS INDICATE IN A DIAGRAMMATIC MANNER, THE DESIRED LOCATIONS OF ARRANGEMENT OF THE COMPONENTS OF ELECTRICAL WORK. DETERMINE EXACT CONDUIT ROUTING, CONDUIT BENDS, AUXILIARY JUNCTION BOXES, SUPPORTS, AND UNDEFINED CONSTRUCTION DETAILS AS A JOB CONDITION TO BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE CODE REQUIREMENTS. PROPER JUDGEMENT MUST BE EXERCISED IN EXECUTING THE WORK SO AS TO SECURE THE BEST POSSIBLE INSTALLATION IN THE AVAILABLE SPACE, AND TO OVERCOME LOCAL DIFFICULTIES DUE TO SPACE LIMITATIONS OR INTERFERENCE OF CONDITIONS ENCOUNTERED.

15. IN THE EVENT CHANGES IN THE INDICATED LOCATIONS OR ARRANGEMENTS ARE NECESSARY, DUE TO DEVELOPED CONDITIONS IN THE BUILDING CONSTRUCTION OR REARRANGEMENT OF EQUIPMENT, SUCH CHANGES SHALL BE MADE WITHOUT COST PROVIDING THE CHANGE IS ORDERED BEFORE THE CONDUIT RUNS, ETC., AND WORK DIRECTLY CONNECTED TO SAME IS INSTALLED AND NO EXTRA MATERIALS ARE REQUIRED.

16. THE DRAWINGS INDICATE APPROXIMATE LOCATIONS OF EXISTING CONDUITS. THE EXACT ROUTING SHALL BE VERIFIED IN FIELD AND LENGTH OF CONDUCTORS SHALL BE ADJUSTED TO THE LENGTH REQUIRED.

17. PERFORM CUTTING AND PATCHING ON THE CONSTRUCTION WORK WHICH MAY BE REQUIRED FOR THE PROPER INSTALLATION OF THE ELECTRICAL WORK. PATCHING SHALL BE OF THE SAME MATERIAL, WORKMANSHIP AND FINISH AS SPECIFIED AND ACCURATELY MATCH SURROUNDING WORK TO SATISFACTION OF THE ARCHITECT.

18. PROVIDE ALL EQUIPMENT WITH ENCLOSURES LISTED OR LABELED FOR USE AND LOCATION WHERE SUCH EQUIPMENT IS INSTALLED.

19. PROVIDE UL LISTED FIRE STOP FOR ALL PENETRATIONS THROUGH FIRE RATED FLOORS, WALLS AND CEILINGS TO MAINTAIN ALL FIRE RATINGS. THE FIRE STOP MATERIALS SHALL BE RE-ENTERABLE AND REUSABLE.

20. PROVIDE COORDINATED SHOP DRAWINGS. INDICATING DIMENSIONED LOCATIONS AND SIZES OF ALL CORE DRILLS FOR REVIEW AND APPROVAL. ALL CORE DRILL LOCATIONS SHALL BE VERIFIED AND APPROVED WITH OWNERS REPRESENTATIVE, STRUCTURAL AND ARCHITECT PRIOR TO CORE DRILL. UTILIZE X-RAY EQUIPMENT TO LOCATE AND VERIFY EXISTING STRUCTURAL ELEMENTS WITHIN SLAB.

21. WHERE EXISTING CIRCUITS ARE SHOWN ON PLANS, THE INFORMATION WAS OBTAINED FROM RECORD DRAWINGS. WHERE NEW CIRCUITS ARE SHOWN IN EXISTING PANELBOARD(S), THE CONTRACTOR SHALL VERIFY THAT THE INDICATED CIRCUITS ARE AVAILABLE IN THE EXISTING PANELBOARD(S), THE CONTRACTOR SHALL RELOCATE SUCH CIRCUITS TO AN AVAILABLE SPACE IN THE EXISTING PANELBOARD(S), AND "AS BUILT" PLANS. IF NO CIRCUIT SPACE IS AVAILABLE IN THE EXISTING PANELBOARD(S), THE CONTRACTOR SHALL REPORT THE DISCREPANCY TO THE ARCHITECT.

22. GROUNDING SHALL BE EXECUTED IN ACCORDANCE WITH ALL APPLICABLE CODES AND REGULATIONS, BOTH OF THE STATE OF CALIFORNIA AND LOCAL AUTHORITIES HAVING JURISDICTION.

FLOORFINISHED

CONTROL BOXTOP OF

MOUNTING HEIGHT

48" M

AX

OVER OBSTRUCTION

34" M

AX

24" MAX

44" M

AX F

RONT

APP

ROAC

H46

" MAX

SID

E AP

PROA

CH

TOP OFCONTROL BOX

AT W

ORKS

TATI

ONS

MOUNTING HEIGHT OVER OBSTRUCTION ASCALE

BOTTOM OFOUTLET BOX

15"MIN.

ABOVE FINISH FLOOR

ABOVE FINISH GRADE

AMERICAN WIRE GAUGE

AMPERE

AMP FRAME, AMP TRIP

AMP SWITCH, AMP FUSE

AUDIO VISUAL

AUTONOMOUS PUBLIC ADDRESS

CIRCUIT

CIRCUIT BREAKER

CONDUIT

CONDUIT ONLY

CONNECTED

DIAMETER

ENERGY MANAGEMENT CONTROL SYSTEM

ELECTRICAL METALLIC TUBING

ELECTRIC WATER COOLER

END-OF-LINE CIRCUIT TERMINATOR

EXHAUST FAN

EXISTING EQUIPMENT

FEET

FIRE ALARM

FULL LOAD AMPS

GROUND FAULT INTERRUPTER

GROUND

HEATING, VENTILATING AND AIR CONDITIONING

HEIGHT, WIDTH, DEPTH, LENGTH

HORSEPOWER

INTERMEDIATE DISTRIBUTION FRAME

INCHES

ISOLATED GROUND

JUNCTION BOX

KILOVOLT AMPERES

KILOWATT

LONG CONTINUOUS LOAD

LUGS ONLY

LIGHTING

MAIN CIRCUIT BREAKER

MAIN DISTRIBUTION FRAME

METAL HALIDE

MOTOR CONTROL CENTER

THOUSAND CIRCULAR MILS

MOTOR CIRCUIT PROTECTOR

MAIN LUGS ONLY

MOUNTED

NATIONAL ELECTRICAL CODE

NORMALLY CLOSED

NORMALLY OPENED

NOT IN CONTRACT

NUMBER

OVER 600 VOLTS

PHASE

FURNISH, INSTALL AND CONNECT

PUBLIC ADDRESS

PULL BOX

REMOVE EXISTING EQUIPMENT

RECEPTACLE

REFRIGERATOR

RIGID GALVANIZED STEEL

600 VOLTS AND LESS

INDICATES DEVICE ON SURFACE WALLMOUNTED OUTLET BOX.

TELEVISION

TYPICAL

UNLESS NOTED OTHERWISE

VOLTS

VOLT AMPERES

WEATHERPROOF

WIRE

DISTRICT FURNISHED CONTRACTOR INSTALLED

DISTRICT FURNISHED DISTRICT INSTALLED

BUILDING

AUDIO/VIDEO CABINET

SINGLE POLE

DOUBLE POLE

TRIPLE POLE

A.F.F.

A.F.G.

AWG

AMP, A

AF/AT

AS/AF

AV

APA

CIRC., CKT.

CB

C

C.O.

CONN

DIA

EMCS

EMT

EWC

E-O-L

EF

E

FT. OR '

FA

FLA

GFI

GRD

HVAC

H.,W.,D.,L.

HP

IDF

IN. OR "

IG

J-BOX

KVA

KW

LCL

L.O.

LTG, LTS

MCB

MDF

MH

MCC

MCM

MCP

MLO

MTD

NEC

NC

NO

NIC

NO. OR #

PRIMARY

PH. OR

PROVIDE

PA

PB

RE

REC, RECEPT

REF

RGS

SECONDARY

O

TV

TYP

U.N.O.

V

VA

WP

W

DFCI

DFDI

BLDG.

AVC

1P

2P

3P

ABBREVIATIONS

OS

a,b2,PS

1EF

B-5,7,9

CONDUIT, INSTALLED EXPOSED.

1/2" C - 3 #12, 1#12(GRD) 1" C - 7 #12, 1#12(GRD) 3/4" C - 4 #12, 1#12(GRD) 1" C - 8 #12, 1#12(GRD)

1/2" C - 2 #12, 1#12(GRD) 3/4" C - 6 #12, 1#12(GRD)

3/4" C - 5 #12, 1#12(GRD) 1 1/4" C - 9 #12, 1#12(GRD)

CONDUIT, INSTALLED CONCEALED IN OR UNDER FLOOR OR BELOW GRADE, 3/4" CONDUIT MINIMUM.

CONDUIT, INSTALLED CONCEALED IN WALL OR IN CEILING SPACE.

HOMERUN TO PANEL "B" FOR CIRCUITS 5, 7, 9 WITH COMMON NEUTRAL.

+45''

E-2C

1002

J

PLAN NOTE CALLOUT. REFER TO CORRESPONDING NOTE ON DRAWING WHERE CALLOUT OCCURS.

UNDERGROUND CONDUIT STUBOUT, STUB 5'-0" FROM BUILDING OR WALKWAY, CAP, MARK AND RECORD.

1

(ALL SYMBOLS NOT NECESSARILY USED ON THESE DRAWINGS)ALL SYMBOL DESCRIPTIONS ARE SUBJECT TO MODIFICATION AS NOTED ON THE DRAWINGS.

VERIFY EXACT LOCATIONS AND HEIGHTS OF OUTLETS WITH ARCHITECTURAL INTERIORELEVATIONS PRIOR TO ROUGH-IN.

MECHANICAL EQUIPMENT CALLOUT. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATIONS AND

DETAIL CALLOUT, "C" INDICATES DETAIL, "E-2" INDICATES DRAWING WHERE DETAIL OCCURS.

OCCUPANCY MOTION SENSOR ON FLUSH CEILING MOUNTED OUTLET BOX.

SINGLE POLE TOGGLE SWITCH, ON FLUSH WALL MOUNTED OUTLET BOX, +45". INSTALL MULTIPLE SWITCHES UNDER COMMON COVER PLATE. SUBSCRIPT OR SUPERSCRIPT AT SWITCH SYMBOL INDICATES THE FOLLOWING: 2 - DOUBLE POLE 4 - FOUR WAY M - MANUAL MOTOR STARTERS 3 - THREE WAY P - PILOT LIGHT K - KEY OPERATED R - SPDT MOMENTARY CONTACT RELAY SWITCH V - VAPOR PROOF a,b,c,d, ETC. - MULTIPLE SWITCHES WITH IDENTIFICATION OF OUTLET CONTROLLED.

FIXTURE SCHEDULE DESIGNATION: "2" INDICATES FIXTURE TYPE, "100" INDICATES FIXTURE TOTAL WATTAGE.

LIGHTING FIXTURE RECESSED MOUNTED WITH OUTLET BOX AND REMOTE MOUNTED JUNCTION BOX CONCEALED ABOVE ACCESSIBLE CEILING. PROVIDE FLEXIBLE CONDUIT CONNECTION 6 FT. MAXIMUM LENGTH,1/2" DIAMETER MINIMUM, FROM JUNCTION BOX TO FIXTURE OUTLET. PROVIDE CONDUCTORS IN CONDUIT,

LIGHTING FIXTURE WITH LAMPS ON NORMAL AND EMERGENCY LIGHTING CIRCUITS, PROVIDE SEPARATE

OUTLET ON EMERGENCY LIGHTING CIRCUIT.

LIGHTING FIXTURE, SURFACE OR FLUSH MOUNTED AS INDICATED ON FIXTURE SCHEDULE, ON WALL MOUNTED OUTLET BOX, +90". STEM INDICATES WALL MOUNTED OUTLET BOX, TYPICAL.

LIGHTING FIXTURE, RECESS MOUNTED, WITH OUTLET BOX.

LIGHTING FIXTURE, SURFACE OR PENDANT MOUNTED, ON FLUSH CEILING MOUNTED OUTLET BOX.

LIGHTING FIXTURE, SURFACE OR PENDANT MOUNTED ON FLUSH MOUNTED OUTLET BOX.

LIGHTING FIXTURE, RECESS MOUNTED, WITH OUTLET BOX.

MOUNTING HEIGHT TO CENTER LINE OF DEVICE FROM FINISH FLOOR OR EXTERIOR GRADE

REQUIREMENTS OF MECHANICAL EQUIPMENT.

LAMP BALLASTS AS REQUIRED.

QUANTITY AS REQUIRED FOR INDICATED CIRCUITS AND SWITCHING CONTROLS, #12 (AWG) MINIMUM.

23. PROVIDE GROUND WIRE IN EACH CONDUIT CONTAINING CIRCUITS FEEDING LIGHTING AND PANEL. THE CONDUIT SHALL NOT BE PERMITTED TO SERVE AS THE ONLY ELECTRICAL GROUND RETURN PATH.

24. WHERE CIRCUIT CHANGES OR ADDITIONS OCCUR IN PANELBOARDS UPDATE PANEL DIRECTORY CARDS WITH NEW TYPEWRITTEN CARDS INDICATING DESCRIPTION OF ALL CIRCUITS.

25. PROVIDE HANDLE TIES AT CIRCUIT BREAKERS TO SIMULTANEOUSLY DISCONNECT ALL UNGROUNDED CONDUCTORS OF MULTI-WIRE BRANCH CIRCUITS WITH A SHARED NEUTRAL.

26. UNLESS NOTED OTHERWISE ALL 120 VOLT HOMERUNS OVER 100 FEET SHALL BE #10 AWG MINIMUM. ADJUST CONDUIT SIZE ACCORDINGLY.

27. UNLESS NOTED OTHERWISE ALL 277 VOLT HOMERUNS OVER 200 FEET SHALL BE #10 AWG MINIMUM, OVER 300 FEET SHALL BE #8 AWG MINIMUM. ADJUST CONDUIT SIZE ACCORDINGLY.

28. CONDUIT FOR VOICE/DATA CABLING SHALL COMPLY WITH THE FOLLOWING ADDITIONAL REQUIREMENTS:

a. INSIDE BEND RADIUS SHALL BE AT LEAST 10 TIMES ITS INTERNAL DIAMETER.

b. PROVIDE PULL BOXES WHENEVER CONDUIT LENGTH EXCEEDS 150 FEET AND WHEN COMBINED BENDS ARE GREATER THAN 180 DEGREES.

c. ALL CONDUIT SHALL BE PROVIDED WITH INSULATED BUSHINGS.

d. MAINTAIN A MINIMUM CLEARANCE OF 4 FEET FROM MOTORS AND TRANSFORMERS.

e. MAINTAIN A MINIMUM CLEARANCE OF 12 INCHES FROM POWER CIRCUITS.

29. COORDINATE MOUNTING HEIGHTS OF RECEPTACLES, SWITCHES, A/V DEVICES, SECURITY DEVICES, ETC. MOUNTED ON COMMON WALLS SO THAT ALL OUTLETS ARE MOUNTED TO ALIGN HORIZONTALLY.

30. NOTIFY THE ARCHITECT IN WRITING WHEN INSTALLATION IS COMPLETE AND THAT A FINAL INSPECTION OF THIS WORK CAN BE PERFORMED. IN THE EVENT DEFECTS OR DEFICIENCIES ARE FOUND DURING THIS FINAL INSPECTION, THEY SHALL BE CORRECTED TO THE SATISFACTION OF THE ARCHITECT BEFORE FINAL ACCEPTANCE CAN BE ISSUED.

ANCHORAGE NOTES SYMBOL LIST

WALKWAY LIGHTING HEAD AND POLE ON CONCRETE BASE.

FIRE ALARM SUBMITTAL IS A COMPLETE PLANSUBMITTAL IN ACCORDANCE WITH PROJECTSUBMITTAL GUIDELINE, GL-2 (FLS) DATED 2/10/11

FIRE ALARM NOTES

MEP COMPONENT ANCHORAGE NOTE

ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON THE DSAAPPROVED CONSTRUCTION DOCUMENTS. THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE ANDDISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2019 CBC SECTIONS 1617A.1.18 THROUGH 1617A.1.26 AND ASCE 7-16 CHAPTER 13, 26AND 30.

1. ALL PERMANENT EQUIPMENT AND COMPONENTS.2. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY ATTACHED (E.G. HARD WIRED) TO THE BUILDING UTILITY SERVICESSUCH AS ELECTRICITY, GAS OR WATER. "PERMANENTLY ATTACHED" SHALL INCLUDE ALL ELECTRICAL CONNECTIONS EXCEPT PLUGS FOR110/220 VOLT RECEPTACLES HAVING A FLEXIBLE CABLE.3. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400 POUNDS OR HAS A CENTER OF MASS LOCATED 4 FEET ORMORE ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT ARE REQUIRED TO BE RESTRAINED IN AMANNER APPROVED BY DSA.

THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE BUT NEED NOTDEMONSTRATE DESIGN COMPLIANCE WITH REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLE CONNECTIONSPROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. FLEXIBLE CONNECTIONS MUUST ALLOWMOVEMENT IN BOTH TRANSVERSE AND LONGITUDINAL DIRECTIONS:

A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER OF MASS LOCATED 4 FEET OR LESS ABOVE THE ADJACENT FLOOROR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT.B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER FOOT, WHICHARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.

THE ANCHORAGE OF ALL MECHANICAL, ELECTRICAL AND PLUMBING COMPONENTS SHALL BE SUBJECT TO THE APPROVAL OF THE DESIGNPROFESSIONAL IN GENERAL RESPONSIBLE CHARGE OR STRUCTURAL ENGINEER DELEGATED RESPONSIBILITY AND ACCEPTANCE BY DSA.THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH ABOVEREQUIREMENTS.

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE

PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTSPRESCRIBED IN ASCE 7-16 SECTION 13.3 AS DEFINED IN ASCE 7-16 SECTIONS 13.6.5, 13.6.6, 13.6.7, 13.6.8; AND 2019 CBC, SECTIONS 1617A.1.24,1617A.1.25 AND 1617A.1.26.

THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED DISTRIBUTION SYSTEM ARE AS NOTEDBELOW. WHEN BRACING AND ATTACHMENTS ARE BASED ON A PREAPPROVED INSTALLATION GUIDE (e.g., OSHPD OPM FOR 2013 CBC ORLATER), COPIES OF THE BRACING SYSTEM INSTALLATION GUIDE OR MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OFAND DURING THE HANGING AND BRACING OF THE DISTRIBUTION SYSTEMS. THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THEADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS.

MECHANICAL PIPING (MP), MECHANICAL DUCTS (MD), PLUMBING PIPING (PP), ELECTRICAL DISTRIBUTION SYSTEMS (E):

MP MD PP E - OPTION 1: DETAILED ON THE APPROVED DRAWINGS WITH PROJECT SPECIFIC NOTES AND DETAILS.

MP MD PP E - OPTION 2: SHALL COMPLY WITH APPLICABLE OSHPD PRE-APPROVAL (OPM#) #________________.

DUPLEX CONVENIENCE RECEPTACLE, WITH INTERNAL GROUND FAULT INTERRUPTER, IN FLUSH WALL MOUNTED ENCLOSURE, +18".

(NOTE: REFER TO SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS)

1. FIXTURES WITH THE SAME TYPE # SHALL BE THE PRODUCTS OF THE SAME MANUFACTURER, (I.E., TYPE #1, 1A, 1B, ETC., SHALL BE THE SAME MANUFACTURER).

2. THE CONTRACTOR SHALL VERIFY DEPTH OF ALL RECESSED LIGHTING FIXTURES WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING FIXTURES. ANY DISCREPANCIES THAT WILL CAUSE RECESSED FIXTURES NOT TO FIT INTO CEILING/WALLSPACES SHALL BE REPORTED TO THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING SHOP DRAWINGS AND PRIOR TO ORDERING FIXTURES.

3. WALL AND CEILING INSULATION SHALL BE INSTALLED TO ALLOW 3" MINIMUM CLEARANCE FROM BOTTOM, SIDES AND TOP OF RECESSED LIGHT FIXTURES.

4. VERIFY MOUNTING HEIGHT OF ALL WALL MOUNTED FIXTURES WITH ARCHITECT PRIOR TO ROUGH-IN.

5. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS AND WALL ELEVATIONS FOR EXACT INSTALL LOCATION OF ALL FIXTURES.

6. VERIFY VOLTAGE BEING SUPPLIED TO FIXTURES PRIOR TO SUBMITTING SHOP DRAWINGS AND PRIOR TO ORDERING. FIXTURE VOLTAGE SHALL MATCH BRANCH CIRCUITS CONNECTING TO RESPECTIVE FIXTURE.

7. OCCUPANCY MOTION SENSOR SYSTEM SHALL BE PROVIDED IN EVERY ROOM/SPACE LOCATION WITHIN THE BUILDINGS AND AS DESCRIBED IN THE SPECIFICATIONS, WHETHER SYMBOLS ARE SHOWN OR NOT SHOWN ON THE PLANS.

8. PROVIDE TESTING CERTIFICATION AND COMMISSIONING OF LIGHTING FIXTURES, INSTALLATION, LIGHTING CONTROL SYSTEM AND LIGHTING SYSTEM OPERATION.

9. CONTRACTOR SHALL COORDINATE INSTALLATION OF RECESSED LIGHTING FIXTURES IN HARD LID OR STUCCO CEILING AREAS WITH FRAMING CONTRACTOR.

FIXTURE NOTES

SHEET INDEXSheet Number Sheet Title

E000 SYMBOL LIST, FIXTURE SCHEDULE, NOTES AND DETAILS

E100

E101

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

No.

NO

T FO

R C

ON

STR

UC

TIO

N

westbergwhitearchitecture

150 Paularino Avenue Suite A120Costa Mesa, CA 92626949.852.9995 949.852.1657 (fax)

FBAEngineeringConsulting Electrical Engineers

fbaengr.com

FBA Job Number: 223.103

FBA

Engi

neer

ing

/ P

lot D

ate:

1/2

6/20

21 1

1:01

AM

/ P

lotte

d by

: Don

Fle

isch

man

/ D

raw

ing

Loca

tion:

I:\2

23\1

03\E

000-

Sym

bol L

ist N

otes

and

Det

ails

.dw

g

ENLARGED LIGHTING AND FIRE ALARM PLANS

ENLARGED POWER AND SIGNAL PLANS

ENTRANCE LIGHTING DIMMING CONTROL STATION ON FLUSH WALL MOUNTED OUTLET BOX, +45"E

SINGLE RECEPTACLE, NEMA CONFIGURATION PER EQUIPMENT MANUFACTURER REQUIREMENTS, ON FLUSH

DUPLEX CONVENIENCE RECEPTACLE HORIZONTAL ON FLUSH WALL MOUNTED OUTLET BOX, +6" ABOVE

DUPLEX CONVENIENCE RECEPTACLE VERTICAL ON FLUSH WALL MOUNTED OUTLET BOX, +18". STEM INDICATES WALL MOUNTED OUTLET BOX, TYPICAL.

WALL MOUNTED OUTLET BOX, +18".

COUNTER SPLASH.

CEILING MOUNTED SPEAKER.S

E000

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fulle

rton

Col

lege

FBA

FBA

11/24/2020

20029

BLD

G 1

000

IMPR

OVEM

ENTS

321

E Cha

pman

Ave

Fulle

rton

Ca.

928

32

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
I
AutoCAD SHX Text
R
AutoCAD SHX Text
T
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
Z
AutoCAD SHX Text
A
AutoCAD SHX Text
J
AutoCAD SHX Text
I
AutoCAD SHX Text
C
AutoCAD SHX Text
E
AutoCAD SHX Text
K
AutoCAD SHX Text
E
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
P
AutoCAD SHX Text
H
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
R.
AutoCAD SHX Text
No. E 10372
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
P
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
T
AutoCAD SHX Text
S
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
R
AutoCAD SHX Text
A
AutoCAD SHX Text
R
AutoCAD SHX Text
E
AutoCAD SHX Text
E
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
G
AutoCAD SHX Text
N
AutoCAD SHX Text
E
AutoCAD SHX Text
L
AutoCAD SHX Text
A
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
I
AutoCAD SHX Text
S
AutoCAD SHX Text
S
AutoCAD SHX Text
L
AutoCAD SHX Text
I
AutoCAD SHX Text
F
AutoCAD SHX Text
O
AutoCAD SHX Text
R
AutoCAD SHX Text
N
AutoCAD SHX Text
I
AutoCAD SHX Text
A
AutoCAD SHX Text
S
AutoCAD SHX Text
T
AutoCAD SHX Text
A
AutoCAD SHX Text
T
AutoCAD SHX Text
E
AutoCAD SHX Text
O
AutoCAD SHX Text
F
AutoCAD SHX Text
C
AutoCAD SHX Text
Exp.
AutoCAD SHX Text
09-30-22

PARTIAL SINGLE LINEDIAGRAM, PANELSCHEDULES AND DETAILS

PARTIAL SINGLE LINE DIAGRAM 1SCALE

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

No.

NO

T FO

R C

ON

STR

UC

TIO

N

westbergwhitearchitecture

150 Paularino Avenue Suite A120Costa Mesa, CA 92626949.852.9995 949.852.1657 (fax)

FBAEngineeringConsulting Electrical Engineers

fbaengr.com

FBA Job Number: 223.103

FBA

Engi

neer

ing

/ P

lot D

ate:

1/2

0/20

21 3

:19

PM /

Plo

tted

by: D

on F

leis

chm

an /

Dra

win

g Lo

catio

n: I:

\223

\103

\E00

1-Si

ngle

Lin

e D

iagr

am P

anel

s an

d D

etai

ls.d

wg

E001

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fulle

rton

Col

lege

FBA

FBA

11/24/2020

20029

BLD

G 1

000

IMPR

OVEM

ENTS

321

E Cha

pman

Ave

Fulle

rton

Ca.

928

32

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

N.T.S.

FULLERTON COLLEGE BLDG 1000 IMPROVMENTS PROJECT NO. 223.103

VOLTS 120/208 PANELBOARD F1 MAIN 50APHASE 3PH, 4W BUS 100A MTG FLUSH LOCATION OPEN OFFICE 102

<-- LOAD (VA) --> LOAD OUTLET <-- LOAD (VA) --> LOAD OUTLET CKT A B C TYPE BKR QUAN DESCRIPTION CKT A B C TYPE BKR QUAN DESCRIPTION

1 360 ----- ----- R 20/1 2 OFFICE 101 CONV.RECEPTS A 2 360 ----- ----- R 20/1 2 FURNITURE FEED3 ----- 1000 ----- R 20/1 1 COPIER B 4 ----- 360 ----- R 20/1 2 FURNITURE FEED5 ----- ----- 20/1 SPARE C 6 ----- ----- 360 R 20/1 2 FURNITURE FEED7 ----- ----- 20/1 SPARE A 8 360 ----- ----- R 20/1 2 FURNITURE FEED9 ----- ----- 20/1 SPARE B 10 ----- 360 ----- R 20/1 2 FURNITURE FEED11 ----- ----- 20/1 SPARE C 12 ----- ----- 360 R 20/1 2 FURNITURE FEED13 ----- ----- PROVISION A 14 360 ----- ----- R 20/1 2 FURNITURE FEED15 ----- ----- PROVISION B 16 ----- 360 ----- R 20/1 2 FURNITURE FEED17 ----- ----- PROVISION C 18 ----- ----- 360 R 20/1 2 OPEN OFFICE 102 CONV RECEPTS19 ----- ----- PROVISION A 20 ----- ----- 20/1 SPARE21 ----- ----- PROVISION B 22 ----- ----- 20/1 SPARE23 ----- ----- PROVISION C 24 ----- ----- 20/1 SPARE25 ----- ----- PROVISION A 26 ----- ----- PROVISION27 ----- ----- PROVISION B 28 ----- ----- PROVISION29 ----- ----- PROVISION C 30 ----- ----- PROVISION31 ----- ----- PROVISION A 32 ----- ----- PROVISION33 ----- ----- PROVISION B 34 ----- ----- PROVISION35 ----- ----- PROVISION C 36 ----- ----- PROVISION37 ----- ----- PROVISION A 38 ----- ----- PROVISION39 ----- ----- PROVISION B 40 ----- ----- PROVISION41 ----- ----- PROVISION C 42 ----- ----- PROVISION

CONNECTED: L.C.L. @ 125% = LOAD TYPE: VA AMPS RECEPT. ( > 10 kVA @ 50%) = 4600

PHASE A = 1440 12 KITCHEN @ 65% = G - GENERAL (100%) M - MOTOR (100%) PHASE B = 2080 17 OTHER LOAD @ 100% = L - L.C.L. (125%) M1 - MOTOR (125%) PHASE C = 1080 9 TOTAL VA = 4600 R - RECEPTACLE ( 50%) X - X-RAY (100%)

(10 kVA @ 100%) X1 - X-RAY ( 50%) TOTAL = 4600 13 TOTAL AMPS = 13 K - KITCHEN ( 65%)

(E)PANEL

"F"

PANEL

"F1"

1 1/

4"C

-4#6

, 1#6

GR

D

PANELBOARD ANCHORAGE DETAIL - FLUSH SCALE

N.T.S.

#12-14 X LENGTH REQ'DTYPICAL AT 6 PLACES 1-1/2"

MIN. PENETRATES STUD

5/8" TYPE "X" GYPSUMBOARD

5/8" TYPE "X" GYPSUMBOARD

WHERE RATED WALLS OCCUR,PROVIDE DRYWALL ON ALL 5SIDES OF RECESSED BOX. ONTHE BACKSIDE, PROVIDE AN

ADDITIONAL DRYWALL LAYERAND AIR GAP

STUDS PER ARCH AT 16" O.C.(X 4" MIN.)

STUD HEADER/SILL TOP ANDBOTTOM 5/8" TYPE "X" GYPSUM

BOARD

PANELBOARDAPPROX. WEIGHT:100 LBS(48"H X 20"W X 5.79"D)

SILL TO BE 12"BELOW PANEL

21" MAX.

2

FULLERTON COLLEGE BLDG 1000 IMPROVMENTS PROJECT NO. 223.103

VOLTS 120/208 PANELBOARD EXISTING "F" MAIN M.L.O.PHASE 3PH, 4W BUS 225A MTG FLUSH LOCATION CORRIDOR

<-- LOAD (VA) --> LOAD OUTLET <-- LOAD (VA) --> LOAD OUTLET CKT A B C TYPE BKR QUAN DESCRIPTION CKT A B C TYPE BKR QUAN DESCRIPTION

1 ----- ----- 20/1 EXISTING LOAD A 2 ----- ----- 20/1 EXISTING LOAD3 ----- ----- 20/1 EXISTING LOAD B 4 ----- ----- 20/1 EXISTING LOAD5 ----- ----- 20/1 EXISTING LOAD C 6 ----- ----- 20/1 EXISTING LOAD7 ----- ----- 20/1 EXISTING LOAD A 8 ----- ----- 20/1 EXISTING LOAD9 ----- ----- 20/1 EXISTING LOAD B 10 ----- ----- 20/1 EXISTING LOAD11 ----- ----- 20/1 EXISTING LOAD C 12 ----- ----- 20/1 EXISTING LOAD13 ----- ----- 20/1 EXISTING LOAD A 14 ----- ----- 20/1 EXISTING LOAD15 ----- ----- 20/1 EXISTING LOAD B 16 ----- ----- 20/1 EXISTING LOAD17 ----- ----- 20/1 EXISTING LOAD C 18 ----- ----- 20/1 EXISTING LOAD19 ----- ----- 20/1 EXISTING LOAD A 20 ----- ----- 20/1 EXISTING LOAD21 ----- ----- 20/1 EXISTING LOAD B 22 ----- ----- 20/2 EXISTING LOAD23 ----- ----- 20/1 EXISTING LOAD C 24 ----- ----- -- --25 ----- ----- 20/1 EXISTING LOAD A 26 ----- ----- 20/1 EXISTING LOAD27 ----- ----- 20/1 EXISTING LOAD B 28 ----- ----- 20/1 EXISTING LOAD29 ----- ----- 20/1 EXISTING LOAD C 30 ----- ----- 20/1 EXISTING LOAD31 ----- ----- 20/1 EXISTING LOAD A 32 ----- ----- 20/2 EXISTING LOAD33 ----- ----- 20/1 EXISTING LOAD B 34 ----- ----- -- --35 ----- ----- 20/1 EXISTING LOAD C 36 ----- ----- 20/1 EXISTING LOAD37 ----- ----- 20/1 EXISTING LOAD A 38 1440 ----- ----- *50/3 NEW SUBFEED PANEL F139 ----- ----- 20/1 EXISTING LOAD B 40 ----- 2080 ----- -- --41 ----- ----- 20/1 EXISTING LOAD C 42 ----- ----- 1080 -- --

CONNECTED: L.C.L. @ 125% = LOAD TYPE: VA AMPS RECEPT. ( > 10 kVA @ 50%) =

PHASE A = 1440 12 KITCHEN @ 65% = G - GENERAL (100%) M - MOTOR (100%) PHASE B = 2080 17 OTHER LOAD @ 100% = 4600 L - L.C.L. (125%) M1 - MOTOR (125%) PHASE C = 1080 9 TOTAL VA = 4600 R - RECEPTACLE ( 50%) X - X-RAY (100%)

(10 kVA @ 100%) X1 - X-RAY ( 50%) TOTAL = 4600 13 TOTAL AMPS = 13 K - KITCHEN ( 65%)

* - PROVIDE NEW CIRCUIT BREAKER SIZE AS INDICATED, MATCH EXISTING TYPE AND AIC RATING. MOVE EXISTING BRANCH CIRCUITS THAT ARE TO REMAIN TO CIRCUIT BREAKERS THAT WERE CLEARED DURING DEMOLITION PHASE. UPDATE PANEL DIRECTORY.

OFFICE127D

(N.I.C.)

671 SF

OPEN OFFICE102

200 SF

PRIVATE OFFICE101

LIMIT OF WORK

LIMI

T OF

WOR

K

15cd

30cd

5

Z

V,Z V,Z

J

S,V,Z

S,V,Z

TO EXISTING FIRE ALARM CONTROL PANEL IN ROOM 1018-M

LIMIT OF WORK

LIMI

T OF

WOR

K

E

E

E

OS

OSOS

OSOS

A134 (TYPICAL)

A1EM34 (TYPICAL)

X13 (TYPICAL)4

J

JJ J

JJ

J

J

J

1 (TYPICAL)

2 (TYPICAL)

3

a

aaa

a a

a a a

b

bb

b

3

b a

a

LIMIT OF WORK

LIMI

T OF

WOR

K

OS

OS

OS

(RE)(RE)(RE)

(RE)(RE)(RE)

(RE)

(RE)(RE)(RE)

(RE) (RE)

(RE)

(RE)

(RE)

(RE)

(RE) (RE) (RE) (RE)

(RE)

(RE)

(RE)

(RE)

1 1

1 1

1

1 1 1

111

1

1 1 1 1

6

2

2

2

3

3

3

2

EXISTING SECT'Y127A

EXISTING STOR.127B

EXISTING OFFICE127C

OFFICE127D

(N.I.C.)EXISTING WORK RM.

127

LIMIT OF WORK

LIMI

T OF

WOR

K

(RE)

(RE)

(RE)

4

55

ENLARGED LIGHTING ANDFIRE ALARM PLANS

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

No.

NO

T FO

R C

ON

STR

UC

TIO

N

westbergwhitearchitecture

150 Paularino Avenue Suite A120Costa Mesa, CA 92626949.852.9995 949.852.1657 (fax)

FBAEngineeringConsulting Electrical Engineers

fbaengr.com

FBA Job Number: 223.103

FBA

Engi

neer

ing

/ P

lot D

ate:

1/2

0/20

21 3

:20

PM /

Plo

tted

by: D

on F

leis

chm

an /

Dra

win

g Lo

catio

n: I:

\223

\103

\E10

0-En

larg

ed L

ight

ing

and

Fire

Ala

rm P

lans

.dw

g

E100

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fulle

rton

Col

lege

FBA

FBA

11/24/2020

20029

BLD

G 1

000

IMPR

OVEM

ENTS

321

E Cha

pman

Ave

Fulle

rton

Ca.

928

32

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1/4" = 1'-0" 1DEMOLITION LIGHTING PLAN 1/4" = 1'-0" 3RENOVATION LIGHTING PLAN

1/4" = 1'-0" 2DEMOLITION FIRE ALARM PLAN 1/4" = 1'-0" 4RENOVATION FIRE ALARM PLAN

1

DEMOLITION PERFORMANCE NOTES2

RENOVATION NOTES:

LIGHTING DIMMING CONTROLS.

CEILING MOUNTED OCCUPANCY SENSOR.

INTERCEPT AND EXTEND EXISTING LIGHTING BRANCH CIRCUIT INEXISTING J BOX IN ACCESSIBLE CEILING SPACE.

PROVIDE NON SWITCHED CIRCUIT TO EXIT SIGN.

INTERCEPT AND EXTEND EXISTING FIRE ALARM NAC AND SLC LOOP. USEEXISTING CIRCUITS THAT WERE REMOVED DURING DEMOLITION.

DEMOLITION NOTES:

DISCONNECT AND REMOVE EXISTING LIGHTING FIXTURE ANDASSOCIATED CONDUIT AND WIRING BACK TO J BOX IN ACCESSIBLECEILING SPACE. PRESERVE ALL THROUGH WIRING. CAP OFF WIRING IN JBOX FOR RECONNECTION TO THE LIGHTING IN THE RENOVATION PHASEOF THE PROJECT.

DISCONNECT AND REMOVE EXISTING LIGHTING CONTROL SWITCHES ANDASSOCIATED WIRING BACK TO J BOX IN ACCESSIBLE CEILING SPACE.PROTECT CONCEALED CONDUIT AND BOX IN PLACE.

DISCONNECT AND REMOVE EXISTING LIGHTING CONTROL OCCUPANCYSENSOR AND ASSOCIATED CONDUIT AND WIRING BACK TO J BOX INACCESSIBLE CEILING SPACE.

DISCONNECT AND REMOVE EXISTING FIRE ALARM SPEAKER STROBE ANDASSOCIATED CONDUIT AND WIRING BACK TO J BOX IN ACCESSIBLECEILING SPACE. PRESERVE ALL THROUGH WIRING.

DISCONNECT AND REMOVE EXISTING FIRE ALARM STROBE ANDASSOCIATED CONDUIT AND WIRING BACK TO J BOX IN ACCESSIBLECEILING SPACE. PRESERVE ALL THROUGH WIRING.

DISCONNECT AND REMOVE EXISTING LIGHTING CONTROL SWITCH ANDASSOCIATED CONDUIT AND WIRING BACK TO J BOX IN ACCESSIBLECEILING SPACE.

1

2

3

4

5

1

2

3

4

5

6

1. ALL EXISTING ELECTRICAL WITHIN THE DEMOLITION AREAS OF THE BUILDING SHALLREMAIN UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE ELECTRICAL DRAWINGS.REFER TO ARCHITECTURAL WALL DEMOLITION DRAWINGS INCLUDED IN THIS SET FORDEMOLITION AREAS, AND EXISTING WALLS. THE SCOPE OF THE DEMOLITION WORK SHALLINCLUDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT REQUIRED FOR THEREMOVAL OF ALL EXISTING ELECTRICAL NOT INDICATED AS BEING REUSED. THIS WORKINCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:

a. ALL EXISTING WIRE SHALL BE REMOVED FROM CONDUIT.

b. ALL EXISTING CONDUIT, THAT INTERFERES WITH ANY NEW CONSTRUCTION SHALL BECUT BACK AS REQUIRED TO CLEAR NEW CONSTRUCTION.

c. REMOVE ALL EXISTING EXPOSED CONDUIT, SURFACE RACEWAYS AND CONDUITCONCEALED IN EXISTING CONSTRUCTION THAT IS TO BE REMOVED. RECONNECTOUTLETS AND LIGHTING FIXTURES WHICH ARE NOW FED THROUGH THE OUTLETS TO BEREMOVED.

d. REMOVE ALL EXPOSED CONDUIT, WIRE, OUTLETS, DISCONNECT SWITCHES ANDELECTRICAL MOUNTING HARDWARE FOR MECHANICAL EQUIPMENT BEING REMOVED.PROVIDE WEATHERPROOF CAPS ON ALL CONDUIT PENETRATING ROOF AND ABANDONCONDUIT. REPAIR ROOFING DAMAGED BY REMOVAL OF EXISTING ELECTRICAL.

e. EXCEPT WHERE EXPOSED CONDUITS ARE SHOWN ON PLANS, INSTALL ALL NEWCONDUITS CONCEALED IN WALLS, FURRED CEILING, OR UNDER FLOOR SPACE.

f. ALL REMOVED MATERIALS AND EQUIPMENT WHICH IN THE OPINION OF THE OWNER ARESALVAGEABLE, SHALL REMAIN THE PROPERTY OF THE OWNER. DELIVER SUCHSALVAGED MATERIALS AND EQUIPMENT ON PREMISES AS DIRECTED, AND NEATLY PILEOR STORE THEM AND PROTECT FROM DAMAGE.

g. DO NOT REUSE SALVAGED MATERIALS AND EQUIPMENT, UNLESS SPECIFICALLYINDICATED ON PLANS OR SPECIFIED. REMOVE FROM PREMISES AND DISPOSE OF ALLMATERIALS CONSIDERED BY THE OWNER TO BE SCRAP.

h. DO NOT REUSE SALVAGED MATERIALS AND EQUIPMENT, UNLESS SPECIFICALLY INDICATED ON PLANS OR SPECIFIED. REMOVE FROM PREMISES AND DISPOSE OF ALL MATERIALS CONSIDERED BY ARCHITECT TO BE SCRAP.

2. CONTRACTOR SHALL INCLUDE ALL WORK NECESSARY TO KEEP EXISTING ELECTRICAL,SIGNAL AND FIRE ALARM SYSTEMS IN ALL AREAS ADJACENT TO DEMOLITIONRECONSTRUCTION AREAS IN SERVICE CONTINUOUSLY UNTIL WORK IN THAT AREA ISCOMPLETE. THIS WORK SHALL INCLUDE, BUT IS NOT LIMITED TO, INSTALLATION OFTEMPORARY ELECTRICAL PANELS OR TEMPORARY RELOCATIONS OF EXISTINGELECTRICAL PANELS, TEMPORARY EXTENSION AND RECONNECTION FEEDERS ANDBRANCH CIRCUITS, TEMPORARY RELOCATION OF SIGNAL AND FIRE ALARM TERMINALCABINETS AND EQUIPMENT AND EXTENSION AND RECONNECTION OF SIGNAL CABLES, ETC.AS REQUIRED TO MAINTAIN ALL ELECTRICAL, SIGNAL AND FIRE ALARM FUNCTIONS. PRIORTO DISCONNECTING ANY ELECTRICAL, SIGNAL AND FIRE ALARM EQUIPMENT OR DEVICESLOCATED IN AREAS REQUIRED TO BE IN SERVICE, ALL EQUIPMENT, CONDUIT, WIRE,CABLING ETC. (TEMPORARY OR OTHERWISE) SHALL BE IN PLACE AND READY AS MUCH ASPRACTICABLE FOR IMMEDIATE RECONNECTION SO AS TO MINIMIZE DOWNTIME.CONTRACTOR SHALL SUBMIT A LETTER TO OWNER TWO (2) WEEKS PRIOR TO ANYPLANNED DISCONNECTION OF ELECTRICAL, SIGNAL AND FIRE ALARM FUNCTIONSINDICATING DESIRED DOWNTIME SCHEDULE AND SHALL NOT PROCEED WITH THIS WORKUNTIL SCHEDULE IS APPROVED.

3. ELECTRICAL DEMOLITION DRAWINGS DO NOT SHOW ALL ELECTRICAL WORK THAT IS TO BEREMOVED. REFER TO ALL DEMOLITION DRAWINGS OF OTHER TRADES/DISCIPLINES FORWORK THAT AFFECTS ELECTRICAL DEMOLITION WORK.

4. DISPOSAL OF HAZARDOUS MATERIALS SUCH AS LAMPS SHALL BE DISPOSED OF INACCORDANCE WITH ALL STATE AND FEDERAL REQUIREMENTS.

PLAN NOTES

LIGHTING PERFORMANCE NOTES1. 0-10V DIMMING AND CONTROL WIRING NOT SHOWN FOR CLARITY. CONTRACTOR SHALL PROVIDE A

COMPLETE NETWORKED LIGHTING CONTROL SYSTEM AS MANUFACTURED BY WATT STOPPER INACCORDANCE WITH THE DISTRICT STANDARDS AND SPECIFICATIONS. CONTRACTOR SHALL PROVIDE ALL0-10V DIMMING AND CONTROL WIRING IN MINIMUM 3/4" C. FOR A COMPLETE AND OPERABLE SYSTEM.

2. LOCATIONS OF LIGHTING OCCUPANCY SENSORS AND WALL CONTROLS ARE SHOWN DIAGRAMMATICALLY.LIGHTING ROOM CONTROLLERS SHALL BE MOUNTED ABOVE THE SWITCHES IN THE ACCESSIBLE CEILINGSPACE ABOVE THE T-BAR CEILING. ALL LIGHTING OCCUPANCY SENSORS AND WALL CONTROLS SHALL BEPLACED IN LOCATIONS IN ACCORDANCE WITH THE LIGHTING CONTROL SYSTEMS MANUFACTURER'SREQUIREMENTS.

3. ALL BRANCH CIRCUIT WIRING SHALL BE IN A MINIMUM 3/4" CONDUIT, UNLESS IT IS A SINGLE WHIP TOTERMINATE AT LIGHT FIXTURE. THEN CONDUIT SIZE CAN BE REDUCED TO 1/2" IN SIZE.

4. PROVIDE GROUND WIRE IN ALL LIGHTING BRANCH CIRCUIT CONDUITS.

SIZE

3/4"C.

CONDUCTORS

2#16TP (SLC LOOP), 2#12THHN (STROBE)

FIRE ALARM RACEWAY SCHEDULE

3/4"C.2#16TP (SLC LOOP)

3/4"C.& 2#16TSP (SPEAKER)

Z

S,V,Z

WIRETAGIN CONDUIT

2#16TP (SLC LOOP) & 2#12THHN (STROBE)V,Z

OFFICE127D

(N.I.C.)

671 SF

OPEN OFFICE102

200 SF

PRIVATE OFFICE101

LIMIT OF WORK

LIMI

T OF

WOR

K

WAP

2D 4D 4D

4D4D

4D

4D

2

S

S (ER)

(ER)

2D1

1

3(TYPICAL)

EXISTING SECT'Y127A

EXISTING STOR.127B

EXISTING OFFICE127C

OFFICE127D

(N.I.C.)EXISTING WORK RM.

127

LIMIT OF WORK

LIMI

T OF

WOR

K

+48"

+48"

+48"

+48"

(RE)

(RE) (RE)

(RE)

(RE)

(E)

SS (ER) (ER)

1

+48"

(RE)

1

2

3

3

EXISTING SECT'Y127A

EXISTING STOR.127B

EXISTING OFFICE127C

OFFICE127D

(N.I.C.)EXISTING WORK RM.

127

LIMIT OF WORK

LIMI

T OF

WOR

K

+72" +48"

J

+96"

J

(E)(E)

(E)

(RE)

(E)

(E)

(RE)

(RE)

(RE)

(RE)

(RE) (RE) (RE)

(RE)

(RE)

(RE)

(RE)

(RE)+48"

(RE)+48"

(RE)+48"

(RE)+48"

(RE)

+96"

(RE)

(RE)

4

5

4 4 4

4

4 4

4

4

4

4

4

44444 4

OFFICE127D

(N.I.C.)

671 SF

OPEN OFFICE102

200 SF

PRIVATE OFFICE101

LIMIT OF WORK

LIMI

T OF

WOR

K

J

J

JJ

(E)

(E)4(TYPICAL)

3

F-1,3 51

1

F-2,4,6,8 6

F1E001

FE001 (E)

F-10,12,14,16 6

18

18

F-18 7

ENLARGED POWER ANDSIGNAL PLANS

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

No.

NO

T FO

R C

ON

STR

UC

TIO

N

westbergwhitearchitecture

150 Paularino Avenue Suite A120Costa Mesa, CA 92626949.852.9995 949.852.1657 (fax)

FBAEngineeringConsulting Electrical Engineers

fbaengr.com

FBA Job Number: 223.103

FBA

Engi

neer

ing

/ P

lot D

ate:

1/2

0/20

21 3

:20

PM /

Plo

tted

by: D

on F

leis

chm

an /

Dra

win

g Lo

catio

n: I:

\223

\103

\E10

1-En

larg

ed P

ower

and

Sig

nal P

lans

.dw

g

E101

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fulle

rton

Col

lege

FBA

FBA

11/24/2020

20029

BLD

G 1

000

IMPR

OVEM

ENTS

321

E Cha

pman

Ave

Fulle

rton

Ca.

928

32

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801

1/4" = 1'-0" 1DEMOLITION POWER PLAN 1/4" = 1'-0" 3RENOVATION POWER PLAN

1/4" = 1'-0" 2DEMOLITION SIGNAL PLAN 1/4" = 1'-0" 4RENOVATION SIGNAL PLAN

1

2

DEMOLITION PERFORMANCE NOTES

2

RENOVATION NOTES:

INSTALL EXISTING SPEAKER, THAT WAS REMOVED IN DEMOLITION PHASE,AND CONNECT TO EXISTING CABLING IN ACCESSIBLE CEILING SPACE.

ALL DATA CABLING TO BE ROUTED IN ACCESSIBLE CEILING TO IDF ROOM1026 AND TERMINATED IN EXISTING IDF.

PROVIDE AND INSTALL DATA FURNITURE FEED IN ACCORDANCE WITH THEMANUFACTURER'S REQUIREMENTS. PROVIDE RACEWAY, CABLING, BOXES,DEVICES ETC. REFER TO FURNITURE DRAWINGS FOR LOCATION ANDADDITIONAL REQUIREMENTS.

PROVIDE AND INSTALL POWER FURNITURE FEED IN ACCORDANCE WITH THEMANUFACTURER'S REQUIREMENTS. PROVIDE RACEWAY, CONDUCTORS,BOXES, DEVICES ETC. REFER TO FURNITURE DRAWINGS FOR LOCATION ANDADDITIONAL REQUIREMENTS.

PROVIDE AND INSTALL 4#12, 1#12GRD - 3/4"C.

PROVIDE AND INSTALL 4#10 (HOT), 4#10 (NEUTRAL), 1#10GRD. - 3/4"C.

PROVIDE 2#12, 1#12GRD - 3/4"C.

DEMOLITION NOTES:

DISCONNECT AND REMOVE EXISTING PA SPEAKER, STORE THE SPEAKER TOAVOID DAMAGE, COIL CABLING ABOVE CEILING AND PROTECT FORRECONNECTION IN THE RENOVATIONS PHASE.

DISCONNECT AND REMOVE EXISTING DATA/TELECOM POLE WITH DATADEVICES, BOXES AND CABLING BACK TO IDF.

DISCONNECT AND REMOVE EXISTING WALL MOUNTED DATA DEVICES,CONDUIT, BOXES AND CABLING BACK TO THE IDF.

DISCONNECT AND REMOVE EXISTING WALL MOUNTED POWER OUTLETDEVICES, CONDUIT, BOXES AND WIRING. PRESERVE THROUGH WIRING.

DISCONNECT EXISTING PEDESTAL MOUNT RECEPTACLE AND J BOX.DISCONNECT WIRING BACK TO PANEL AND MARK BREAKER AS SPARE.PROVIDE FLUSH MOUNT COVER PLATE.

1

2

3

4

5

6

7

1

2

3

4

5

1. ALL EXISTING ELECTRICAL WITHIN THE DEMOLITION AREAS OF THE BUILDING SHALLREMAIN UNLESS SPECIFICALLY INDICATED OTHERWISE ON THE ELECTRICAL DRAWINGS.REFER TO ARCHITECTURAL WALL DEMOLITION DRAWINGS INCLUDED IN THIS SET FORDEMOLITION AREAS, AND EXISTING WALLS. THE SCOPE OF THE DEMOLITION WORK SHALLINCLUDE ALL LABOR, MATERIALS, SERVICES AND EQUIPMENT REQUIRED FOR THEREMOVAL OF ALL EXISTING ELECTRICAL NOT INDICATED AS BEING REUSED. THIS WORKINCLUDES, BUT IS NOT LIMITED TO, THE FOLLOWING:

a. ALL EXISTING WIRE SHALL BE REMOVED FROM CONDUIT.

b. ALL EXISTING CONDUIT, THAT INTERFERES WITH ANY NEW CONSTRUCTION SHALL BECUT BACK AS REQUIRED TO CLEAR NEW CONSTRUCTION.

c. REMOVE ALL EXISTING EXPOSED CONDUIT, SURFACE RACEWAYS AND CONDUITCONCEALED IN EXISTING CONSTRUCTION THAT IS TO BE REMOVED. RECONNECTOUTLETS AND LIGHTING FIXTURES WHICH ARE NOW FED THROUGH THE OUTLETS TO BEREMOVED.

d. REMOVE ALL EXPOSED CONDUIT, WIRE, OUTLETS, DISCONNECT SWITCHES ANDELECTRICAL MOUNTING HARDWARE FOR MECHANICAL EQUIPMENT BEING REMOVED.PROVIDE WEATHERPROOF CAPS ON ALL CONDUIT PENETRATING ROOF AND ABANDONCONDUIT. REPAIR ROOFING DAMAGED BY REMOVAL OF EXISTING ELECTRICAL.

e. EXCEPT WHERE EXPOSED CONDUITS ARE SHOWN ON PLANS, INSTALL ALL NEWCONDUITS CONCEALED IN WALLS, FURRED CEILING, OR UNDER FLOOR SPACE.

f. ALL REMOVED MATERIALS AND EQUIPMENT WHICH IN THE OPINION OF THE OWNER ARESALVAGEABLE, SHALL REMAIN THE PROPERTY OF THE OWNER. DELIVER SUCHSALVAGED MATERIALS AND EQUIPMENT ON PREMISES AS DIRECTED, AND NEATLY PILEOR STORE THEM AND PROTECT FROM DAMAGE.

g. DO NOT REUSE SALVAGED MATERIALS AND EQUIPMENT, UNLESS SPECIFICALLYINDICATED ON PLANS OR SPECIFIED. REMOVE FROM PREMISES AND DISPOSE OF ALLMATERIALS CONSIDERED BY THE OWNER TO BE SCRAP.

h. DO NOT REUSE SALVAGED MATERIALS AND EQUIPMENT, UNLESS SPECIFICALLY INDICATED ON PLANS OR SPECIFIED. REMOVE FROM PREMISES AND DISPOSE OF ALL MATERIALS CONSIDERED BY ARCHITECT TO BE SCRAP.

2. CONTRACTOR SHALL INCLUDE ALL WORK NECESSARY TO KEEP EXISTING ELECTRICAL,SIGNAL AND FIRE ALARM SYSTEMS IN ALL AREAS ADJACENT TO DEMOLITIONRECONSTRUCTION AREAS IN SERVICE CONTINUOUSLY UNTIL WORK IN THAT AREA ISCOMPLETE. THIS WORK SHALL INCLUDE, BUT IS NOT LIMITED TO, INSTALLATION OFTEMPORARY ELECTRICAL PANELS OR TEMPORARY RELOCATIONS OF EXISTINGELECTRICAL PANELS, TEMPORARY EXTENSION AND RECONNECTION FEEDERS ANDBRANCH CIRCUITS, TEMPORARY RELOCATION OF SIGNAL AND FIRE ALARM TERMINALCABINETS AND EQUIPMENT AND EXTENSION AND RECONNECTION OF SIGNAL CABLES, ETC.AS REQUIRED TO MAINTAIN ALL ELECTRICAL, SIGNAL AND FIRE ALARM FUNCTIONS. PRIORTO DISCONNECTING ANY ELECTRICAL, SIGNAL AND FIRE ALARM EQUIPMENT OR DEVICESLOCATED IN AREAS REQUIRED TO BE IN SERVICE, ALL EQUIPMENT, CONDUIT, WIRE,CABLING ETC. (TEMPORARY OR OTHERWISE) SHALL BE IN PLACE AND READY AS MUCH ASPRACTICABLE FOR IMMEDIATE RECONNECTION SO AS TO MINIMIZE DOWNTIME.CONTRACTOR SHALL SUBMIT A LETTER TO OWNER TWO (2) WEEKS PRIOR TO ANYPLANNED DISCONNECTION OF ELECTRICAL, SIGNAL AND FIRE ALARM FUNCTIONSINDICATING DESIRED DOWNTIME SCHEDULE AND SHALL NOT PROCEED WITH THIS WORKUNTIL SCHEDULE IS APPROVED.

3. ELECTRICAL DEMOLITION DRAWINGS DO NOT SHOW ALL ELECTRICAL WORK THAT IS TO BEREMOVED. REFER TO ALL DEMOLITION DRAWINGS OF OTHER TRADES/DISCIPLINES FORWORK THAT AFFECTS ELECTRICAL DEMOLITION WORK.

4. DISPOSAL OF HAZARDOUS MATERIALS SUCH AS LAMPS SHALL BE DISPOSED OF INACCORDANCE WITH ALL STATE AND FEDERAL REQUIREMENTS.

PLAN NOTES

SIGNAL PERFORMANCE NOTES1. THE DISTRICT WILL BE HANDLING THE WAPs & TELEPHONES INCLUDING REMOVAL, PACKING, STORAGE,

REINSTALLATION & PROGRAMMING TO THESE DEVICES.

2. VERIFY EXACT LOCATION OF EQUIPMENT/TELECOMMUNICATION OUTLETS WITH ARCHITECT/SCHOOL DISTRICTREPRESENTATIVE PRIOR TO ROUGH-IN.

3. EXISTING WALL MOUNTED CLOCK/SPEAKER TO REMAIN, PROTECT IN PLACE.

4. EXISTING TELEPHONE BOXES, CONDUIT PATHWAY AND CABLING SHALL BE PROTECTED IN PLACE FORTELEPHONE TO BE REINSTALLED BY THE DISTRICT IN SAME LOCATION AFTER CONSTRUCTION IS COMPLETEAS REQUIRED.

5. EXISTING DATA OUTLETS TO REMAIN, PROTECT IN PLACE.

POWER PERFORMANCE NOTES1. ROUTE CONDUIT CONCEALED IN WALLS AND ABOVE ACCESSIBLE CEILING. WHERE WALLS AND CEILINGS ARE

NOT ACCESSIBLE, PROVIDE SURFACE RACEWAY, WIREMOLD 2000 SERIES OR EQUIVALENT.

2. PROVIDE GREEN GROUND WIRE IN ALL LIGHTING AND POWER CONDUITS.

3. INSTALL ALL NEW ELECTRICAL PANELS AND TRANSFORMERS IN LOCATIONS TO PROVIDE ALL CODE REQUIREDCLEARANCES.

TITLE 24 FORMS

14471 CHAMBERS RD, SUITE 210TUSTIN, CA 92780

(714) 508-1780 508-1790 FAX

No.

NO

T FO

R C

ON

STR

UC

TIO

N

westbergwhitearchitecture

150 Paularino Avenue Suite A120Costa Mesa, CA 92626949.852.9995 949.852.1657 (fax)

FBAEngineeringConsulting Electrical Engineers

fbaengr.com

FBA Job Number: 223.103

FBA

Engi

neer

ing

/ P

lot D

ate:

1/2

0/20

21 3

:20

PM /

Plo

tted

by: D

on F

leis

chm

an /

Dra

win

g Lo

catio

n: I:

\223

\103

\E20

0-TI

TLE

24 F

OR

MS.

dwg

E200

NORTH ORANGECOUNTY COMMUNITYCOLLEGE DISTRICT

Fulle

rton

Col

lege

FBA

FBA

11/24/2020

20029

BLD

G 1

000

IMPR

OVEM

ENTS

321

E Cha

pman

Ave

Fulle

rton

Ca.

928

32

1830 W. ROMNEYADRIVE, ANAHEIM,

CA 92801