Sr. No. Consumer No. Consumer Name Meter Type / No. 01 34170013322 Samundri CNG IMRM-7M, 2081838 02 34170011111 Saahil CNG RC-5M, 1117247 03 34120012948 Wali Bhai CNG RC-5M, 0745150 04 34100011415 Nayab CNG RC-5M, 0753227 05 34120013930 Bismillah CNG IMRM-7M, 20900913 06 1556780290 RC-7M, 0334257 07 8709049214 Hassan Spinning RC-16M, 1117509 08 0888771511 IMRM-16M, 2072896 09 31100009356 IMRM-16M, 2072896 10 31100010565 RC-7M, 0753679 11 31100010598 RC-7M, 0042149 12 13 Shalimar CNG 14 31100010361 Zafar Fabrics - 15 34130012983 IMRM-7M, 2076280 16 34130012303 IMRM-7M, 21000702 17 34100010434 Chenab Spinning IMRM-16M, 2081361 18 34130013254 IMRM-7M, 2081637 19 31100008030 Asghar Sizing RC-7M, 0516697 20 21 34100009571 Gohar Textile RC-11M, 0219477 22 Fair Deal Textiles Bin Bashir Textiles Al-Rehmat Textiles Faisal Fabrics (C.P.) M.K. Sons (C.P.) Shaheen CNG, Shorkot Shafiq CNG, Shorkot Farooq CNG, Shorkot

Book1 F.xlsx

Embed Size (px)

Citation preview

Sheet2Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required0134170013322Samundri CNGIMRM-7M, 2081838Fault Volume: 1.08 MCF (Uncorrected)Booking of unregistered volume is recommended.O0234170011111Saahil CNGRC-5M, 1117247Fault Volume: 63.1 MCF (Uncorrected)Booking of unregistered volume is recommended.O0334120012948Wali Bhai CNGRC-5M, 0745150EVC battery found dead.Rectification is required for proper calculation of corrected volume.O0434100011415Nayab CNGRC-5M, 0753227EVC data not retrieved . Mismatch: 2.0 MCF (Uncorrected) EVC reading behind of Mech. CounterRectification is required.O0534120013930Bismillah CNGIMRM-7M, 20900913Fault Volume: 1.34 MCF (Uncorrected)Booking of unregistered volume is recommended.O061556780290Fair Deal TextilesRC-7M, 0334257Mismatch: 5.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter. EVC push button is faultyRectification is required.A078709049214Hassan SpinningRC-16M, 1117509Mismatch: 1.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.N080888771511Bin Bashir TextilesIMRM-16M, 2072896Fault Volume: 1.8 MCF (Uncorrected)Booking of unregistered volume is recommended.A0931100009356Al-Rehmat TextilesIMRM-16M, 2072896Mismatch: 1.5 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.1031100010565Faisal Fabrics (C.P.)RC-7M, 0753679Mismatch: 8.71 MCF (Uncorrected) EVC reading behind of Mech. Counter.H1131100010598M.K. Sons (C.P.)RC-7M, 0042149Mismatch: 6.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.Asif Sb1213Shalimar CNGData logs missing from 26-Apr-13 to 30-Apr-13N1431100010361Zafar Fabrics-Consumer did not allow for CMS inspection & data retrivalAction is required as per company policy.N1534130012983Shaheen CNG, ShorkotIMRM-7M, 2076280EVC battery found dead.Rectification is required for proper calculation of corrected volume.A1634130012303Shafiq CNG, ShorkotIMRM-7M, 21000702Mismatch: 14.43 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.N1734100010434Chenab SpinningIMRM-16M, 2081361Mismatch: 4.6 MCF (Uncorrected) EVC reading behind of Mech. Counter.H1834130013254Farooq CNG, ShorkotIMRM-7M, 2081637EVC magnetic problem1931100008030Asghar SizingRC-7M, 0516697EVC data not retrievedRectification is required.A202134100009571Gohar TextileRC-11M, 0219477EVC data not retrievedRectification is required.H222331100001534AL-Mumtaz TextilesRC-11M, 0641212Mismatch: 34.8 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Meter UnderSize and is generating excessive pulsesRectification is required.Asif Sb2431100002430Madina Oil MillsRW-1600, 110538Mismatch: 6.1 MCF (Uncorrected) EVC reading behind of Mech. Counter. Temperature probe not connectedAsif Sb2531100008836Batala dyeingRC-11M, 0844027Gas Leakage from gauge pointRectification is required.Asif Sb267821487648Midway CNGRC-5M, 0753186 Reduced flowA273110008676Ittefaq DyeingRC-3M, 0843788Mismatch: 7.45 MCF (Uncorrected) EVC reading behind of Mech. Counter.H2831100008386New Kashmir Sizing-Consumer did not allow for CMS inspection & data retrivalAction is required as per company policy.H293031311000Ahmed Jamal RM-23000, 083090Mismatch: 427.1 MCF (Uncorrected) EVC reading behind of Mech. Counter.
Sheet3Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required0131100013661Ahmad Jamal TextileRM23000, 083090Mismatch: 427 MCF (Uncorrected) EVC reading behind of Mech. Counter.Rectification is required.asif sb023696917733Amar CNGIMRM 7M, 2081865Fault Volume: 12.99 MCF (Uncorrected)Booking of fault volume is recommended.abdullah0339100011614Millac FoodsRC-5M, 0334244Mismatch: 5.02 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.abdullah0439100011647Pakistan CNGIMRM 5M, 2080048Oil Plug not sealedRectification is recommended.abdullah0539100009480Shakarganj Mill-Data logs are not available in EVCEVC faulty, rectification is recommended.hassaan06-Davis Energen RM23000, 111065Mismatch: 7.62 MCF (Uncorrected) EVC reading behind of Mech. Counter.Rectification is required.hassaan0831100013401Star Sizing RC-11M, 516787EVC Found Dead. Replacement of batteries is recommendedasif sb0931100010264Modren Sizing RVG G100, 31687EVC Found Dead. Replacement of batteries is recommendedhassaan1031100013951Usman Cloth MillsRC-16M, 640674Meter UndersizedUncorrected Flow Rate often exceeds 20 MCF/h at normal pressuresReplacement & Flow Proving of Meter is recommended.nabeel1131100010071Abdul-Hameed BleachingRW-3000, 58736An extra commercial meter and a S/L exists outside the factory premises.Rectification is recommendedasif sb1231100009312Sahil Limited CNG Filling StationRVG G100, 28947Magnet link is missing.Rectification is recommendednabeel1339100013858Al-Muqeet CNGIMRM 7M, 20922911Pin hole at back side of counter casing observed, moreover Seal wire found loose. Thus declared suspected as Tampered. Replacement & Flow Proving of Meter is recommended. Replacement & Flow Proving of Meter is recommended.hassaan1439100012093Rawal CNGRC-5M, 9818503Mismatch: 31.3 MCF (Uncorrected)EVC Reading ahead of Mech. Counter readingnabeel1531100013746Farooq Faiz Textile Mills RM 23000, 50314Meter UndersizedUncorrected Flow Rate often exceeds 30 MCF/h at normal pressures, moreover, excessive pulses are being generated by EVCReplacement & Flow Proving of Meter is recommendedhassaan1731100010576Arif TextileRC-11M, 940584Mismatch: 1.45 MCF (Uncorrected)EVC Reading ahead of Mech. Counter readingRectification is recommendedabdullah1831100010123Yasir TextileRVG G250, 75079037EVC Found Dead. Replacement of batteries is recommendedasif sb1931100012055Al-Hassan SizingRC-5M, 0334206EVC data not retrievedRectification is recommendedabdullah2031100009345Masood Textile MillsRM 23000, 083243Mismatch: 3.53 MCF (Uncorrected)EVC Reading ahead of Mech. Counter readingRectification is recommendednabeel2131100007725Al-Badar TextileRC-7M, 0516702EVC data not retrievedRectification is recommendednabeel2231100013188Abu Bakar Anees DyeingIMRM 7M, 20710636Loose coupling of EVC with meterRectification is recommended.asif sb
Sheet4Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100012293Hermain CNGRC-11M, 0527133Fault Volume: 73.85 MCF (Uncorrected)Pressure values often drops down to -2 psig.Booking of unregistered volume is recommended.AB231100010747Moheet Textiles RC-11M, 0334303Mismatch: 1.3 MCF (Uncorrected) EVC Reading ahead of mech. Counter reading. Moreover, EVC Data could not be retrieved due to failure in connection with MC. Rectification is recommended.AB331100009710Kamal Fabrics 2RC-7M, 0753390Oil Plug not sealedRectification is recommended.AB431100010060M B Sizing RC-3M, 0640771EVC malfunctioning, EVC data does not display Flow.Correct configuration of EVC is recommended.Asif Sb531100012914City Gas Ways, Jhang RoadIMRM 7M, 2080570Fault Volume: 7.6785 MCF (Uncorrected). S.H.E. intervals with Zero Flows observedBooking of unregistered volume is recommended.N631100012356Chenab CNGIMRM-7M, 2080574Gas Leakage from RegulatorRectification is recommended.Asif Sb731100012709Al Raheem CNGIMRM-5M, 2081281Fault Volume: 64.21 MCF (Uncorrected)Booking of unregistered volume is recommended.Asif Sb831100012248Al Rehman CNGRC-5M, 0743260Mismatch: 4.85 MCF (Uncorrected) EVC reading ahead of Mech. CounterRectification is recommended.AB9 1031100001802Hussain SizingIMRM-5M, 2080895Fault Volume: 104.21 MCF (Uncorrected)Booking of unregistered volume is recommended.N1131100001697Lyallpur SizingRC-3M, 948459EVC data not retrieved . Rectification is required.N1231100008171Mujahid Textile-Consumer did not allow for CMS inspectionAction is required as per company policy.N1331100012958Madina Pak CNGRVG G-100, 75078910Mismatch: 3.06 MCF (Uncorrected) EVC reading ahead of Mech. counterRectification is recommended.Asif Sb
Sheet5Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100002797Arif Zahid HoiseryRW-3000, 14579312Leakage from RegulatorRectification is recommended.AB 231100010338Safe Way CNGRC-7M, 0640957Oil Plug not sealedRectification is recommended.Asif sb331100012011City Gas CNG-Consumer did not allow for CMS inspectionAction is required as per company policy.Asif sb431100010190Safron CNGRC-7M, 1117368Mismatch: 1.15 MCF (Uncorrected) EVC reading behind of Mech. Counter.Rectification is required.AB531100010822Faiz CNGIMRM-7M, 2081675Fault Volume: 29.36 MCF (Uncorrected) Pressure values drops down to -4 psig.Booking of fault volume is recommended.AB632100011787Quality CNGRC-7M, 0242126Mismatch: 1.25 MCF (Uncorrected) EVC reading ahead of Mechanical Counter.Rectification is recommended.Asif sb731100006410Faisalabad Oil MillsRC-11M, 0516751Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mechanical Counter, moreover EVC data was not retrieved .Rectification is recommended.Asif sb831100011900Mian Petroleum CNG, Samundri RoadRC-5M, 0640829Reduced consumption 33 % of connected load Suspected replacement & Flow proving of meter is recommendedAB9Qadri SizingEVC Dead due to BatteryReplacement of batteries is recommendedN1031100013070Kamran TextileRM-23000, 083208Illegal shifting of House Line, moreover EVC data could not be retrieved Rectification is recommended.N11Shams Textile (Bulk)RC-5M, 0516530EVC data could not be retrieved . Mismatch: 9.63 MCF (Uncorrected) EVC reading ahead of Mechanical Counter.Rectification is required.N1231100008030Asgher Sizing RC-7M, 0516697EVC data not retrieved . Rectification is required.N1331100012958Madina Pak CNGRVG G-100, 75078910Mismatch: 3.06 MCF (Uncorrected) EVC reading ahead of Mech. counterRectification is recommended.Asif Sbfile://///10.140.126.5/tariq/Meter%20Replacement%202009/Faisalabad%20Oil%20Refienary,%20Chiniot.jpgfile://///10.140.126.5/tariq/Tariq%20Wahla/Application%20Data/Microsoft/EVC%20Data/Kamran%20Textile%20Pvt,%20Khurrianwala
Sheet6Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100010219Ameen CNGRC-3M, 0843695Fault Volume: 7 MCF (uncorrected)Booking of unregistered Volume is recommendedAsif Sb23110013199Al Hamra FabricsRM 23000, 083210Fault volume : 9.4 MCF (uncorrected)Booking of Unregistered Volume is recommendedH35863590309A.B Export PVT. LTD.RC-11M, 0516782EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .H431100012613Commander CNGRC-5M, 0640824No company lock at CMS door. Rectification is recommended531100010554Jeea Textile RC-5M, 0640942EVC Data Logs unavailable. Faulty EVC needs to be replacedH631100008278sargodha spining-Consumer didnt allow the inspection of CMSAction is required as per company Policy.H731100043401Star textile printing-Consumer didnt allow the inspection of CMSAction is required as per company Policy.N831100013951Usman Cloth MillsRC-16M, 0640674Meter UndersizedUncorrected Flow Rate often exceeds 20 MCF/h at normal pressuresReplacement & Flow Proving of Meter is recommendedAsif Sb931100010071Abdul-Hameed BleachingRW 3000, 58736Leakage from EVC Mechanical Index observed. Provision of fiddling with Meter exists. (Declared Suspected)Replacement & Flow Proving of Meter is recommendedAsif Sb1031100006380Hamid Processing Plant -EVC data could not be retrieved . Moreover, Meter Serial # is unreadable due to abrassion marks. (Declared Suspected as Tampered) Replacement & Flow Proving of Meter is recommendedN1131100008568Data Hajveri SizingIMRM 7M, 21000736Fault Valume: 242.2 MCF (Uncorrected)EVC Data could not be retrieved due to Faulty/ poor configured EVC.Booking of Unregistered volume along with replacement & Flow rpoving of Meter is recommended.H1231100009312Sahil Limited CNG RVG G-100, 00028947Magnet link of EVC is missing.Rectification is recommended.Asif Sb4733985692SubhanAllah ProcessingRC-5M, 0940506Zero Flow observed in many logs of EVC data at Night time during non curtailment days. (Declared Suspected)Replacement & Flow Proving of Meter is recommendedN65272288443A.A. SpinningRC-16M, 1117466Meter revesal observed in many logs of EVC data, Totalling of 10.1 MCFH (corrected)Rectification is recommended.AB31100007598Kausar TextileRC-16M, 0516875EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .AB31100010543Ittehad TextileIMRM 16M, 2080666Gas Leakage observed from RegulatorRectification is recommended.AB31100012334Raheem IndustryRW-3000, 5878Temperature probe is not connectedRectification is recommended.Asif Sb31100012282Tanveer SoapA-1000, 5416899Temperature probe is not connectedRectification is recommended.AB3132100013880Sayazar CNGRC-5M, 0753294Mech. Counter bolt is looseReplacement & Flow Proving of Meter is recommendedAB3231100005785Rafhan Maize StorageRW-3000, 48088Temperature probe is not connectedRectification is recommended.N28293031323304
Sheet7Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100008290Magna Textile MillsIMRM 16M, 2080784EVC counter sticker seems to be re-fixedFlow proving of meter is recommendedA231100009828Aarzoo Textile Mills (C.P.)RC-16M, 05168821) Loose EVC seal. 2)EVC counter bolt. 3)Reverse Flow observed totalling to 7562 SCFH. 4)Leakage observed from RegulatorFlow proving of meter is recommendedAsif sb331100007822Aarzoo Textile MillsRC-56M, 0516836Temperature Probe not connectedRectification is recommended.Asif sb431100010598M.K. Sons (C.P.)RC-7M, 0042149Mismatch: 6.06 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Loose EVC sealRectification is recommended.N531100008966Firdous Cloth MillsRC-16 M, 1117533EVC data logs missing, EVC data only available after 31-May-13A631100010189Interloop-3RC-11M, 0843974Temperature sensor fixing screw openRectification is recommended.N731100010565Faisal Fabrics (C.P.)RC-7M, 0753379Mismatch: 8.49 MCF (Uncorrected) EVC reading ahead of Mechanical Counter.Rectification is recommended.Asif sb831100007844Faisal FabricsRM-38000, 075597Temperature Probe not connectedRectification is recommended.H935100012693City Gas station, Jaranwala RC-5M, 0640924Meter Seal wire brokenReplacement & Flow Proving of Meter is recommendedN1031100009356Al Rehmat TextileIMRM 16M, 2081397Mismatch: 183.96 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Meter Undersize, Uncorrected Flow Rate often exceeds 20 MCF/h at normal pressures and its maximum value reaches 385 MCFReplacement & Flow Proving of Meter is recommendedA1131100013683Five Star TextileIMRM 7M, 2077104Low battery & EVC configuration fault, EVC data does not displays correction factorBattery Replacement & Correct configuration of EVC is recommended.A1231100010521Noor Fatima Textile (C.P.)RC-7M, 0527300EVC counter glass damaged. EVC data showns running load to be 60% of connectedReplacement & Flow Proving of Meter is recommendedH1331100010372Noor Fatima TextileRC 38M, 0242152EVC counter glass damaged. EVC data showns running load to be 60% of connectedReplacement & Flow Proving of Meter is recommendedH1431100004384Ali SizingRVG G65, 75065080Fault Volume: 106 MCF (Uncorrected), due to malfunctioning of Pressure TransducerBooking of fault volume is recommended. Rectification of Pressure Transducer recommendedH157276116092AL-Raheem ProcessingRC-7M, 0036429Meter Undersize, Uncorrected Flow Rate often exceeds 9 MCF/h at normal pressuresReplacement & Flow Proving of Meter is recommendedN1631100010899Crescent Textile Mills-1RC-56M, 0839087Mismatch: 66.4 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.Asif sb1731100000058Crescent Textile Mills-2RM-38000, 083266Mismatch: 70.9 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.Asif sb3031323304
Sheet1Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required0131100011267City CNGIMRM-7M, 21000718Mismatch: 1.43 MCF(Uncorrected) EVC reading behind of Mech. CounterRectification is required.0231100010231Saahil CNGRC-7M, 0312002Gas Leakage from Regulator CaplliaryRectification is required.0331100012594Z.A. FoodsSensus 3000, 14579279Gas Leakage from Regulator CaplliaryRectification is required.HS0431100010811Khawaja CNGRC-5M, 1117186Fault Volume: 4.55MCF (Uncorrected)Booking of unregistered volume is recommended.Asif Sb0531100012743Saddique CNGG-65, 00030355EVC Found Dead.Replacement and flow proving of meter is recommended.Asif Sb0631100013003Zulqernain CNGIMRM-7M, 2081531Fault Volume: 4.35MCF (Uncorrected)Booking of unregistered volume is recommended.HS0731100007349Azhar CoorporationRC-16M, 1117470Reduced flow 22% of connected loadAsif Sb0831100009215Aftab TextileRM-23000, 083093Mismatch: 402.8 MCF (Uncorrected) EVC reading behind of Mech. CounterN094733985692Subhan Allah ProcessingRC-5M, 0940506Mismatch: 10.29 MCF (Uncorrected)EVC reading ahead of Mech. CounterRectification is required.HS1031100010918Al Haram TextileRC-7M, 0640978Mismatch: 10.16 MCF (Uncorrected)EVC reading ahead of Mech. counterRectification is required.N1131100008234Rafique ProcessingRM-23000, 083225Gas Leakage from Regulator Caplliary, Meter oil seems to be less than indicated levelRectification is required.AB1231100013649Rehman CNGIMRM-7M, 2077093Meter seal wire is loose, passing through Mech. CounterRectification is required.N1331100009549Nishat Mills- 3RM-38000, 093937EVC held, not registering Gas Flow. Only mechanical counter is increasingAsif Sb1431100000122Nishat Mills- 1RC-38M, 0334390Reading Reversal totaling 4.5 MCF, 16 eventsRectification is required.AB1537989969649Jamia Ghausia Rasheedabad (Bulk Consumer)G-4, 27213041Counter Glass brokenAsif Sb1635900000045Social Security hospital (Bulk Consumer)Al-1000A, 6032758EVC data not retrieved , EVC push button is faultyRectification is required.WS176555536697Head Master Govt. Islamia School (Bulk Consumer)MR, 2421316Meter Sticky, but gas is passingReplacement of meter and flow proving is recommended.AB18-Crescent Jute Products (Bulk Consumer)RW-3000, 27502EVC data not retrievedRectification is required.WS1931100010219Ameen CNGRC-3M, 0843695Fault Volume: 7.0MCF (Uncorrected)Booking of fault volume is recommended.N2031100007606Sahib TextilesRC-16M, 0242136Mismatch: 3.9 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Booking of fault volume is recommended.N2131100013199Al Hamra FabricsRM-23000, 083210Fault Volume: 7.1 MCF (Uncorrected), Mismatch: 98.79 MCF (Uncorrected) EVC reading ahead of Mech. CounterBooking of fault volume is recommended.WS2231100008278Sargodha Cloth MillsConsumer did not allow for CMS inspectionAction is required as per company policy.HS23Sadiq ProcessingConsumer did not allow for CMS inspectionAction is required as per company policy.N245863590000AB ExportsRC-11M, 0516782EVC data not retrieved Rectification is required.WS
Sheet8Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100008676Ittefaq DyeingRC-3M, 0843788Mismatch: 7.37 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Ab231100005406Punjab CeramicsRW-3000, 14468129Fault Volume: 19.86 MCF (Uncorrected)Pressure values often drops down to -5.19 psig.Booking of unregistered volume & Calibration of Pressure Transducer is recommended.Ab331100006313Fazal Textile-Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Ab431100008494Al-Kareem TextileRC-16M, 0640665Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Ab531100011267City Gas IMRM-7M, 2100718Mismatch: 56.8 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Asif sb631100011397Lyallpur CNGRC-5M, 0753285Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Asif sb731100013928Rachna SweetsRVG G65, 00031571Mismatch: 2.47 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Asif sb831100012839Faiq CNGRC-11M, 9017353Fault Volume: 13.99 MCF (Uncorrected) Pressure values often drops down to -3.32 psig.Booking of unregistered volume & Calibration of Pressure Transducer is recommended.Asif sb931100006700Al-Firdous ProcessingRC-3M, 007511Hourly Data logs are not available in EVCCorrect configuration of EVC is required.Ab1031100005945Al Noor TextileAL-1400, 5653705Mismatch: 18.71 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Ab1131100012840Bright Way CNGRC-11M, 0753464Magnetic Link of EVC is defectiveRectification is recommended.H1231100006346Gulzar dyeingRC-5M, 0516632Mismatch: 2.25 MCF (Uncorrected) EVC reading behind of Mech. Counter.H1431100010424Ali Raza Sizing RC-5M, 0753202Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.3110013199Al Hamra FabricsROMET 23000Consumer resisted the inspection of CMSAsif sb31100010219Ameen CNGRC-3M/0843099Fault Volume: 7 MCF (uncorrected)Booking of unregistered Volume is recommendedH31100010208Ch. & Company CNGRC-5M, 1117201Extended Intervals of Negative Pressure (upto -7 PSIg) observed. Moreover, certain Values of Corrected & Uncorrected Flow found where "No change in Corrected Readings" observed Data Logs. EVC seems to be Suspected tampered. Replacement & Flow proving of Meter is recommended.H31100011881Dawood Usman textileRC-5M,0743254Consumer resisted the inspection of CMSAsif sb31100013746Farooq Faiz Textile Mills RM 23000, 083069Fault Volume: 1.5 MCF (Uncorrected)Excessive pulses are being generated by Faulty EVC.Booking of unregistered volume is recommended. H5512978396Shell Pakistan Pvt-2.5Km Flow Rate often drops to Zero during night hours for more than 8 hours. Declared Suspected as Tampered. Replacement & Flow proving of Meter is recommendedH
June ConsolidatedSr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100010219Ameen CNGRC-3M, 0843695Fault Volume: 7 MCF (uncorrected).Booking of unregistered Volume is recommendedFault Volume: 7 MCF (uncorrected). Booking of unregistered Volume is recommended23110013199Al Hamra FabricsRM 23000, 083210Fault volume : 9.4 MCF (uncorrected).Booking of Unregistered Volume is recommendedFault volume : 9.4 MCF (uncorrected). Booking of Unregistered Volume is recommended35863590309A.B Export PVT. LTD.RC-11M, 0516782EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .431100012613Commander CNGRC-5M, 0640824No company lock at CMS door. Rectification is recommendedNo company lock at CMS door. Rectification is recommended531100010554Jeea Textile RC-5M, 0640942EVC Data Logs unavailable. Faulty EVC needs to be replacedEVC Data Logs unavailable. Faulty EVC needs to be replaced631100008278sargodha spining-Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.731100043401Star textile printing-Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.831100013951Usman Cloth MillsRC-16M, 0640674Meter UndersizedUncorrected Flow Rate often exceeds 20 MCF/h at normal pressures.Replacement & Flow Proving of Meter is recommendedMeter UndersizedUncorrected Flow Rate often exceeds 20 MCF/h at normal pressures. Replacement & Flow Proving of Meter is recommended931100010071Abdul-Hameed BleachingRW 3000, 58736Leakage from EVC Mechanical Index observed. Provision of fiddling with Meter exists. (Declared Suspected).Replacement & Flow Proving of Meter is recommendedLeakage from EVC Mechanical Index observed. Provision of fiddling with Meter exists. (Declared Suspected). Replacement & Flow Proving of Meter is recommended1031100006380Hamid Processing Plant -EVC data could not be retrieved . Moreover, Meter Serial # is unreadable due to abrassion marks (Declared Suspected as Tampered).Replacement & Flow Proving of Meter is recommendedEVC data could not be retrieved . Moreover, Meter Serial # is unreadable due to abrassion marks (Declared Suspected as Tampered). Replacement & Flow Proving of Meter is recommended1131100008568Data Hajveri SizingIMRM 7M, 21000736Fault Valume: 242.2 MCF (Uncorrected)EVC Data could not be retrieved due to Faulty/ poor configured EVC.Booking of Unregistered volume along with replacement & Flow rpoving of Meter is recommended.Fault Valume: 242.2 MCF (Uncorrected)EVC Data could not be retrieved due to Faulty/ poor configured EVC. Booking of Unregistered volume along with replacement & Flow rpoving of Meter is recommended.1231100009312Sahil Limited CNG RVG G-100, 00028947Magnet link of EVC is missing.Rectification is recommended.Magnet link of EVC is missing. Rectification is recommended.134733985692SubhanAllah ProcessingRC-5M, 0940506Zero Flow observed in many logs of EVC data at Night time during non curtailment days (Declared Suspected).Replacement & Flow Proving of Meter is recommendedZero Flow observed in many logs of EVC data at Night time during non curtailment days (Declared Suspected). Replacement & Flow Proving of Meter is recommended1465272288443A.A. SpinningRC-16M, 1117466Meter revesal observed in many logs of EVC data, Totalling of 10.1 MCFH (corrected).Rectification is recommended.Meter revesal observed in many logs of EVC data, Totalling of 10.1 MCFH (corrected). Rectification is recommended.1531100007598Kausar TextileRC-16M, 0516875EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .EVC data could not be retrieved due to failure in connection with MC. Rectification is recommended .1631100010543Ittehad TextileIMRM 16M, 2080666Gas Leakage observed from Regulator.Rectification is recommended.Gas Leakage observed from Regulator. Rectification is recommended.1731100012334Raheem IndustryRW-3000, 5878Temperature probe is not connected.Rectification is recommended.Temperature probe is not connected. Rectification is recommended.1831100012282Tanveer SoapA-1000, 5416899Temperature probe is not connected.Rectification is recommended.Temperature probe is not connected. Rectification is recommended.1932100013880Sayazar CNGRC-5M, 0753294Mech. Counter bolt is loose.Replacement & Flow Proving of Meter is recommendedMech. Counter bolt is loose. Replacement & Flow Proving of Meter is recommended2031100005785Rafhan Maize StorageRW-3000, 48088Temperature probe is not connected.Rectification is recommended.Temperature probe is not connected. Rectification is recommended.2131100008290Magna Textile MillsIMRM 16M, 2080784EVC counter sticker seems to be re-fixed.Flow proving of meter is recommendedEVC counter sticker seems to be re-fixed. Flow proving of meter is recommended2231100009828Aarzoo Textile Mills (C.P.)RC-16M, 05168821) Loose EVC seal. 2)EVC counter bolt. 3)Reverse Flow observed totalling to 7562 SCFH. 4)Leakage observed from Regulator.Flow proving of meter is recommended1) Loose EVC seal. 2)EVC counter bolt. 3)Reverse Flow observed totalling to 7562 SCFH. 4)Leakage observed from Regulator. Flow proving of meter is recommended2331100007822Aarzoo Textile MillsRC-56M, 0516836Temperature probe is not connected.Rectification is recommended.Temperature probe is not connected. Rectification is recommended.2431100010598M.K. Sons (C.P.)RC-7M, 0042149Mismatch: 6.06 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Loose EVC seal.Rectification is recommended.Mismatch: 6.06 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Loose EVC seal. Rectification is recommended.2531100008966Firdous Cloth MillsRC-16 M, 1117533EVC data logs missing, EVC data only available after 31-May-13.EVC data logs missing, EVC data only available after 31-May-13. 2631100010189Interloop-3RC-11M, 0843974Temperature sensor fixing screw open.Rectification is recommended.Temperature sensor fixing screw open. Rectification is recommended.2731100010565Faisal Fabrics (C.P.)RC-7M, 0753379Mismatch: 8.49 MCF (Uncorrected) EVC reading ahead of Mechanical Counter.Rectification is recommended.Mismatch: 8.49 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.2831100007844Faisal FabricsRM-38000, 075597Temperature probe is not connected.Rectification is recommended.Temperature probe is not connected. Rectification is recommended.2935100012693City Gas station, Jaranwala RC-5M, 0640924Meter Seal wire broken.Replacement & Flow Proving of Meter is recommendedMeter Seal wire broken. Replacement & Flow Proving of Meter is recommended3031100009356Al Rehmat TextileIMRM 16M, 2081397Mismatch: 183.96 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Meter Undersize, Uncorrected Flow Rate often exceeds 20 MCF/h at normal pressures and its maximum value reaches 385 MCF.Replacement & Flow Proving of Meter is recommendedMismatch: 183.96 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Meter Undersize, Uncorrected Flow Rate often exceeds 20 MCF/h at normal pressures and its maximum value reaches 385 MCF. Replacement & Flow Proving of Meter is recommended3131100013683Five Star TextileIMRM 7M, 2077104Low battery & EVC configuration fault, EVC data does not displays correction factor.Battery Replacement & Correct configuration of EVC is recommended.Low battery & EVC configuration fault, EVC data does not displays correction factor. Battery Replacement & Correct configuration of EVC is recommended.3231100010521Noor Fatima Textile (C.P.)RC-7M, 0527300EVC counter glass damaged. EVC data showns running load to be 60% of connected.Replacement & Flow Proving of Meter is recommendedEVC counter glass damaged. EVC data showns running load to be 60% of connected. Replacement & Flow Proving of Meter is recommended3331100010372Noor Fatima TextileRC 38M, 0242152EVC counter glass damaged. EVC data showns running load to be 60% of connected.Replacement & Flow Proving of Meter is recommendedEVC counter glass damaged. EVC data showns running load to be 60% of connected. Replacement & Flow Proving of Meter is recommended3431100004384Ali SizingRVG G65, 75065080Fault Volume: 106 MCF (Uncorrected), due to malfunctioning of Pressure Transducer.Booking of fault volume is recommended. Rectification of Pressure Transducer recommendedFault Volume: 106 MCF (Uncorrected), due to malfunctioning of Pressure Transducer. Booking of fault volume is recommended. Rectification of Pressure Transducer recommended357276116092AL-Raheem ProcessingRC-7M, 0036429Meter Undersize, Uncorrected Flow Rate often exceeds 9 MCF/h at normal pressures.Replacement & Flow Proving of Meter is recommendedMeter Undersize, Uncorrected Flow Rate often exceeds 9 MCF/h at normal pressures. Replacement & Flow Proving of Meter is recommended3631100010899Crescent Textile Mills-1RC-56M, 0839087Mismatch: 66.4 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.Mismatch: 66.4 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.3731100000058Crescent Textile Mills-2RM-38000, 083266Mismatch: 70.9 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.Mismatch: 70.9 MCF (Uncorrected) EVC reading ahead of Mechanical Counter. Rectification is recommended.3831100008676Ittefaq DyeingRC-3M, 0843788Mismatch: 7.37 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Mismatch: 7.37 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.3931100005406Punjab CeramicsRW-3000, 14468129Fault Volume: 19.86 MCF (Uncorrected)Pressure values often drops down to -5.19 psig.Booking of unregistered volume & Calibration of Pressure Transducer is recommended.Fault Volume: 19.86 MCF (Uncorrected)Pressure values often drops down to -5.19 psig. Booking of unregistered volume & Calibration of Pressure Transducer is recommended.4031100006313Fazal Textile-Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.4131100008494Al-Kareem TextileRC-16M, 0640665Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4231100011267City Gas IMRM-7M, 2100718Mismatch: 56.8 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Mismatch: 56.8 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.4331100011397Lyallpur CNGRC-5M, 0753285Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 3.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4431100013928Rachna SweetsRVG G65, 00031571Mismatch: 2.47 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 2.47 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4531100012839Faiq CNGRC-11M, 9017353Fault Volume: 13.99 MCF (Uncorrected) Pressure values often drops down to -3.32 psig.Booking of unregistered volume & Calibration of Pressure Transducer is recommended.Fault Volume: 13.99 MCF (Uncorrected) Pressure values often drops down to -3.32 psig. Booking of unregistered volume & Calibration of Pressure Transducer is recommended.4631100006700Al-Firdous ProcessingRC-3M, 007511Hourly Data logs are not available in EVC.Correct configuration of EVC is required.Hourly Data logs are not available in EVC. Correct configuration of EVC is required.4731100005945Al Noor TextileAL-1400, 5653705Mismatch: 18.71 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 18.71 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4831100012840Bright Way CNGRC-11M, 0753464Magnetic Link of EVC is defective.Rectification is recommended.Magnetic Link of EVC is defective. Rectification is recommended.4931100006346Gulzar dyeingRC-5M, 0516632Mismatch: 2.25 MCF (Uncorrected) EVC reading behind of Mech. Counter.Mismatch: 2.25 MCF (Uncorrected) EVC reading behind of Mech. Counter. 5031100010424Ali Raza Sizing RC-5M, 0753202Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.513110013199Al Hamra FabricsROMET 23000Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.5231100010219Ameen CNGRC-3M/0843099Fault Volume: 7 MCF (uncorrected)Booking of unregistered Volume is recommendedFault Volume: 7 MCF (uncorrected) Booking of unregistered Volume is recommended5331100010208Ch. & Company CNGRC-5M, 1117201Extended Intervals of Negative Pressure (upto -7 PSIg) observed. Moreover, certain Values of Corrected & Uncorrected Flow found where "No change in Corrected Readings" observed Data Logs. EVC seems to be Suspected tampered. Replacement & Flow proving of Meter is recommended.Extended Intervals of Negative Pressure (upto -7 PSIg) observed. Moreover, certain Values of Corrected & Uncorrected Flow found where "No change in Corrected Readings" observed Data Logs. EVC seems to be Suspected tampered. Replacement & Flow proving of Meter is recommended.5431100011881Dawood Usman textileRC-5M,0743254Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.5531100013746Farooq Faiz Textile Mills RM 23000, 083069Fault Volume: 1.5 MCF (Uncorrected)Excessive pulses are being generated by Faulty EVC.Booking of unregistered volume is recommended. Fault Volume: 1.5 MCF (Uncorrected)Excessive pulses are being generated by Faulty EVC. Booking of unregistered volume is recommended. 565512978396Shell Pakistan Pvt-2.5Km Flow Rate often drops to Zero during night hours for more than 8 hours. Declared Suspected as Tampered. Replacement & Flow proving of Meter is recommendedFlow Rate often drops to Zero during night hours for more than 8 hours. Declared Suspected as Tampered. Replacement & Flow proving of Meter is recommended5731100012527Arif Mehmood Malik Textile -Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.5831100008030Asgher Sizing RC 7M, 0516697EVC dead.Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended5934100009571Gohar TextileRC-11M, 08219477EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.6039100011614Millac Foods, JhangRC-5M, 0334244EVC dead.Battery Replacement of EVC is recommended.EVC dead. Battery Replacement of EVC is recommended.6139100009480Shaker Gunj MillsRC-56M, 0516837Hourly & Daily data logs are not available in EVC DataRe-configuration of EVC is recommendedHourly & Daily data logs are not available in EVC Data Re-configuration of EVC is recommended62Davis EnergenRM-23000, 111065Mismatch: 13.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 13.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.6339100013245Al Mubarik CNGIMRM 7M, 21000654Reduced consumption 40 % of connected load.Suspected Replacement & Flow proving of meter is recommendedReduced consumption 40 % of connected load. Suspected Replacement & Flow proving of meter is recommended6431100005406Punjab CeramicsRW-3000, 14468129Fault Volume: 19.86 MCF (Uncorrected), EVC data shows 0% battery life.Booking of unregistered volume & Battery Replacement is recommended.Fault Volume: 19.86 MCF (Uncorrected), EVC data shows 0% battery life. Booking of unregistered volume & Battery Replacement is recommended.6539100013029Al-Yousaf CNG3M, 0443409Fault Volume: 48.5 MCF (Uncorrected).Booking of unregistered volume is recommendedFault Volume: 48.5 MCF (Uncorrected). Booking of unregistered volume is recommended6634100007069Bilal IndustryRVG-G65,00029065EVC has stopped. Only Mechanical Counter is working.Suspected Tampered, Replacement & Flow Proving of Meter is recommendedEVC has stopped. Only Mechanical Counter is working. Suspected Tampered, Replacement & Flow Proving of Meter is recommended6739100012093Rawal CNG5M, 8918503(A-Series)Intermittent Flow Pattern observed in EVC Data Logs. Zero flows (for more than 5 hours) found after 5-6 operational hours. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.Intermittent Flow Pattern observed in EVC Data Logs. Zero flows (for more than 5 hours) found after 5-6 operational hours. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.6831100012022Bawa Jee CNG Filling StationConsumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.6934100006903Altaf IndustryRW-3000,48076CMS is without fence boundry and is inside premises.Outlet gauge was not working.Action is required as per company Policy.CMS is without fence boundry and is inside premises.Outlet gauge was not working. Action is required as per company Policy.7032100011527Sheraz (Rapid) CNGRC-5M, 0443425EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.7131100011364Kalash Pvt. LtdRC-7M, 0640625Flow rate often drops to Zero at mid night till morning. Leakage from regulator capillary.Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.Flow rate often drops to Zero at mid night till morning. Leakage from regulator capillary. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.7231100011427Kay & EmmsRC-16M, 1117500EVC dead.Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended7334150012004Paris CNGRC-7M, 0311928EVC dead.Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended7434160011938Kamalia CNGRC-3M, 516408EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.7531100006410Faisalabad Oil Refienry, ChiniotRC-11M, 0516751EVC data not retrieved . Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.EVC data not retrieved . Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.file://///10.140.126.5/tariq/Meter%20Replacement%202009/Faisalabad%20Oil%20Refienary,%20Chiniot.jpg
Sheet924-Jun ~ 7 Jul-2013Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100012527Arif Mehmood Malik Textile -Consumer didnt allow the inspection of CMSAction is required as per company Policy.AB231100008030Asgher Sizing RC 7M, 0516697EVC deadBattery Replacement of EVC is recommendedAB334100009571Gohar TextileRC-11M, 08219477EVC data not retrieved . Rectification is required.AB439100011614Millac Foods, JhangRC-5M, 0334244EVC deadBattery Replacement of EVC is recommended.AB539100009480Shaker Gunj MillsRC-56M, 0516837Hourly & Daily data logs are not available in EVC DataRe-configuration of EVC is recommendedAB6-Davis EnergenRM-23000, 111065Mismatch: 13.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.AB739100013245Al Mubarik CNGIMRM 7M, 21000654Reduced consumption 40 % of connected load.Suspected Replacement & Flow proving of meter is recommendedAB831100005406Punjab CeramicsRW-3000, 14468129Fault Volume: 19.86 MCF (Uncorrected), EVC data shows 0% battery lifeBooking of unregistered volume & Battery Replacement is recommended.ABHassaan139100013029Al-Yousaf CNG3M, 0443409Fault Volume: 48.5 MCF (Uncorrected)Booking of unregistered volume is recommended234100007069Bilal IndustryRVG-G65,00029065EVC has stopped. Only Mechanical Counter is working Suspected Tampered, Replacement & Flow Proving of Meter is recommended339100012093Rawal CNG5M, 8918503(A-Series)Intermittent Flow Pattern observed in EVC Data Logs. Zero flows (for more than 5 hours) found after 5-6 operational hours. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.431100012022Bawa Jee CNG Filling StationConsumer didnt allow the inspection of CMSAction is required as per company Policy.534100006903Altaf IndustryRW-3000,48076CMS is without fence boundry and is inside premises.Outlet gauge was not working.Action is required as per company Policy.Asif Sb132100011527Sheraz (Rapid) CNGRC-5M, 0443425EVC data not retrieved . Rectification is required.231100011364Kalash Pvt. LtdRC-7M, 0640625Flow rate often drops to Zero at mid night till morning. Leakage from regulator capillarySuspected as Tampered. Replacement & Flow Proving of Meter is recommended.331100011427Kay & EmmsRC-16M, 1117500EVC deadBattery Replacement of EVC is recommended434150012004Paris CNGRC-7M, 0311928EVC deadBattery Replacement of EVC is recommended534160011938Kamalia CNGRC-3M, 516408EVC data not retrieved . Rectification is required.631100006410Faisalabad Oil Refienry, ChiniotRC-11M, 0516751EVC data not retrieved . Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.file://///10.140.126.5/tariq/Meter%20Replacement%202009/Faisalabad%20Oil%20Refienary,%20Chiniot.jpg
Sheet1208-Jul ~ 21 Jul-2013Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required17276116092AL-Raheem ProcessingIMRM 7M, 21000688Fault Volume: 4.122 MMCF (Uncorrected)Temperature values often exceeds to 212 FBooking of unregistered volume & Calibration of Temperature Transducer is recommended.231100008234Rafique ProcessingRM-23000, 83225Removal attempts on EVC sticker Suspected replacement & Flow proving of meter is recommended331100007918Mian FabricsIMRM 16M, 2081418Reduced consumption 30 % of connected load. Some time zero flow is observed in non curtailment days. Suspected Replacement & Flow proving of meter is recommended431100008494Al- Kareem IndustryRC-16M, 0640665Mismatch: 3.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.531100006197Tajammal Dyeing-Door lock of CMS is jammed, hence data retrival could not be done.Rectification is recommended.631100007253Sharif TextileRC-5M, 0743171Mismatch: 3.92 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops to Zero on nightsReplacement & Flow Proving of Meter is recommended731100008085Nawab SizingRC-7M, 0312123Gas Leakage form adjustment bolt of Inlet Filter. Zero Flow is observed during night hours. Suspected Urgent rectification is recommended.Chances of gas pilferage exists through Filter831100008007Aala Processing-Consumer didnt allow the inspection of CMSAction is required as per company Policy.931100012970Mian CNGRC 5M, 0640597Mismatch: 2.63 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops on nightsReplacement & Flow Proving of Meter is recommended1031100008126Rays HotelAL-425, 195227Gas leakage from Regulator before meter.Rectification is recommended.1131100008654Sajid Rehman TextileRC-5M, 0640877EVC data not retrieved . Rectification is required.1231100008353Fateh TextileRM-23000, 083072Mismatch: 15.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.134733985692Subhan Allah ProcessingRC-5M, 0940506Mismatch: 10.49 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1431100009895General Chemicals1000A, 6032751EVC data not retrieved . Old Mercury version needs replacement with latest versions.Rectification is required.1531100009613Zaheer BrothersRVG-G65, 00031478Gas leakage from Inlet Service Valve.Rectification is required.1631100013360Fazal -e- Rabbi TextileIMRM 7M, 20900893Mismatch: 6.07 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1731100007048Syed DyeingRC-7M, 0311959Mismatch: 17.13MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.1831100007190Dooab TextileRC-7M, 0312029Mismatch: 1.9MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.ASIF Sb131100012839Faiq CNGRC 11M, 9017353Fault Volume: 289.23 MCF (Uncorrected), due to malfunctioning of Pressure Transducer.Booking of unregistered volume & Calibration of Pressure Transducer is recommended.231100009549Nishat Mills-3RC-38M, 0516832EVC data not retrieved . Mismatch: 5.4 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.331100000122Nishat Mills 1RC-56 M, 0334133Multiple reversals observed in EVC hourly data logs.Rectification is required.431100004265Lyallpur FoundaryRC-5M, 6040493Flow Rate drops to zero during night hours (12 pm ~ 8 am), along with reduced consumption. Suspected Replacement & Flow Proving of Meter is recommended531100012431Madni CNGIMRM 5M, 2081286EVC deadBattery Replacement of EVC is recommended.631100009107Al Ghafoor dyeing RC-5M, 0743233Flow Rate drops to zero during night hours Suspected Replacement & Flow Proving of Meter is recommended731100012226Lyallpur CNG-Consumer didnt allow the inspection of CMSAction is required as per company Policy.831100006379Madina Printing-Consumer didnt allow the inspection of CMSAction is required as per company Policy.931100006959Ittehad (unit-1)IMRM 16M, 2080744Mismatch: 4.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1031100005945Al-Noor TextileAL 1400, 5653705Mismatch: 22.24 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1131100001697Lyallpur SizingRC-3M, 0948459EVC data not retrieved . Mismatch: 1.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is required.1231100001705Jalandher sizingRC-5M, 0753252EVC data not retrieved . Rectification is required.1331100004317Chanda Sizing-Consumer didnt allow the inspection of CMSAction is required as per company Policy.1431100011041Kahloon CNGRC-3M, 0843434Hourly data logs are not available in EVC Memory.Re-configuration of EVC is recommended.1531100000199National Silk MillsRM-23000, 111059Mismatch: 3.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1631100010725National Silk Mills (C.P.)RC-11M, 0843957Mismatch: 40.06 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.1731100011579Vega CNGRC-3M, 0843827EVC data not retrieved . Mismatch: 153.86 MCF (Uncorrected) EVC reading beind of Mech. Counter.Rectification is required & Booking of unbilled volume is recommended.Hassaan131100010071Abdul-Hameed BleachingRW-3000, 48043Flow Rate usually remains b/w 0.3 - 0.6 MCF/hr, though having small intervals of Flow Rate b/w 4-5 MCF/hr. Suspicion of Gas theft exists. A raid with C.P Team is underway231100012293Harmain CNG, Chak No. 73/JB JhapalRC-11M, 0527133Fault Volume: 2081 m (Uncorrected)Booking of Unbilled Volume along with Replacement & Flow Proving of Meter is Recommended331100004243Iftikhar Sizing RC-7M, 0940435Flow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with meter exist. Suspected Replacement & Flow Proving of Meter is recommended431100009958Saad Sizing RVG G65, 00030440Reduced Flow Rate observed as per analysis of EVC Data. Suspicion of Fiddling with meter exist. Suspected Replacement & Flow Proving of Meter is recommended531100013003Zulqarnain CNGIMRM 7M, 2081531Fault Volume: 4.3 MCF (Uncorrected)Booking of unbilled volume is recommended.631100005990Mehboob Finishing Ayub ColonyRVG G65,75065032Flow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with Meter exist. Suspected Replacement & Flow Proving of Meter is recommended731100006380Hamid Processing Factory-EVC data could not be retrieved due to bad configuration. Meter serial no. is not visible from plate.Replacement & Flow Proving of Meter is recommended along with re-configuration of EVC.87443581207Abdullah Husnain DyeingRVG G65, 00031378Plastic Strip on EVC Mechanical Index found loose.Rectification is required931100013768Talha Saad CNG, Chak No. 66IMRM 7M, 2080635Magnetic link at EVC (for Data Cable connection) is missingRectification is required1031100011557Sangam Petroleum Total PARCO outlet, Sudhuar by-passRVG G100, 00031779Regulator found damaged, Plastic Strip on EVC Mechanical Index found looseRectification is required1131100012914City Gas Ways-II CNG Filling station, 74/JBIMRM-7M, 2081677Mismatch: 42.6 MCF (Uncorrected)Booking of Un-billed Volume along with Replacement & flow Proving of Meter is recommended1231100012248Al Rehman CNG, Chak No. 73/JB JhapalRC-5M, 0743260Plastic Strip on EVC Mechanical Index found loose.Rectification is required1331100012055Al Hasan Sizing Industries, Yousaf ChowkRC-5M, 0334206EVC data not could not be retrieved . Mismatch: 17.2 MCF (Uncorrected) EVC Reading ahead of Mech. Counter ReadingReplacement & Flow Proving of Meter is recommended1434100011459Qurai CNGIMRM 5M, 2080009Reduced consumption 30 % of connected load. Never goes to full load despite of Healthy pressure. Suspected replacement & Flow proving of meter is recommended1531100011397Lyallpur CNGRC-5M, 0753285Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1634100013446Kahloon CNGRC-5M, 0516602Mismatch: 1.0 MCF (Uncorrected) EVC reading behind of Mech. Counter. Zero Flows observed during night hoursReplacement & Flow Proving of Meter is recommended
Sheet1122-Jul ~ 4 Aug-2013Sr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100011580Akbar CNGRC-11M, 0527153EVC data not retrieved . (0% Battery life remaining).Rectification is recommended.231100009743Blue Moon CNGRC-5M, 0743204EVC data not retrieved . (0% Battery life remaining).Rectification is recommended.331100011955Laraib CNGRC-5M, 0753278Fault Volume: 1.2 MCF (Uncorrected), due to malfunctioning of Temperature Transducer (value sometime reaches to 159 F).Booking of unbilled volume & calibration of Pressure Transducer is recommended.431100011665Touseef EnterprisesRC-7M, 0753342EVC dead.Rectification is recommended.531100009260Al Jamia SizingRVG G65, 00030425Mismatch: 418.6 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Replacement & Flow proving of meter is recommended631100011267City CNGIMRM-7M, 21000718Mismatch: 56.82 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.77278384186Naveed EnterprisesIMRM 7M, 2081592Temperature probe not connected.Rectification is recommended.878214876480Mid Way CNGRC-5M, 0753186Reduced consumption 33 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommended931100000586United TextileRM-23000, 083231Hourly data logs are not available in EVC.Re-configuration of EVC is recommended.1031100006937Ahmed TextileRC-11M, 0940548Mismatch: 4.13 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1131100010424Ali Raza SizingRC-5M, 0334213Reduced consumption 25 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommended1231100006658Serena HotelRC-5M, 0011452Mismatch: 5.03 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1331100005536Qadria Callendering800-A, 715155Zero Flow is observed during night hours from 12:00 AM to 11:00 AMConsumer is to be kept under vigilence.1431100004759Shahdman CeramicsRW-3000, 14579363Mismatch: 2.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Zero Flow is observed throughoutFactory under maintenance. Consumer is to be kept under vigilence.1531100006766Madni SizingRW-3000, 48829EVC dead.Rectification is recommended.1631100010974Gulzar Dyeing CPRVG G65, 00029028Zero Flow is observed during night hours from 12:00 AM to 6:00 AMSuspected Replacement & Flow proving of meter is recommended1731100006346Gulzar DyeingRC-5M, 0444471EVC data not retrieved . Rectification is recommended.1831100002850Insaf SizingRW-3000, 56400Temperature probe not connected.Rectification is recommended.1931100006476Jelani textile-Consumer didnt allow the inspection of CMS.Action is required as per company Policy.2031100013081Latif ExportRC-7M, 1117369Mismatch: 3.26 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.2131100004997New Sitara SizingRW-3000, 48026No company lock at CMS.Rectification is recommended.2231100000531Insaf TextileRC-16M, 1117480No company lock at CMS.Rectification is recommended.Asif Sb131100010800Al Haq ExportRVG G65, 00030348Mismatch: 18 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.21/7/13231100012453Al Qasim CNGRC-5M, 8918454EVC dead.Rectification is recommended.31556780290Fair Deal TextilesRC-7M, 0334257EVC data not retrieved . (connection problem)Rectification is recommended.431100011104Magna ProcessingIMRM 16M, 2081392Hourly data logs are not available in EVC.Re-configuration of EVC is recommended.25/7/1353696917733Amar CNG StationIMRM 7M, 2081865 Removal attempts seems on EVC counter Sticker. Fault Volume: 12.99 MCF (Uncorrected)Suspected Replacement & Flow proving of meter is recommended631100009345Masood TextileRM-23000, 083243Mismatch: 3.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.73110009431Ishaq TextileRM-23000, 083073Mismatch: 708.5 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.831100008591Ibrahim FibersRM-38000, 0242153EVC data not retrieved .Rectification is recommended.931100011687Friends CNGRC-3M, 0843757Time difference; EVC lags behind 24 MinRectification is recommended.1031100008609Bismillah TextileRC-38M,0516825 Mismatch: 2.9 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1131100010565Faisal Fabrics unit 2 (CP)RC-7M,0753379Mismatch: 8.68 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.12888771511Bin Bashir TextileIMRM-11M, 2072896Fault Volume: 1.16 MCF (Uncorrected)Booking of unbilled volume is recommended.1331100010543Ittehad Textile-CMS lock jammed, due to which CMS checking & data retrival was not possible.Rectification is recommended.1431100008966Firdous Cloth MillsRC-16M, 1117533Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.158709049214Hassan Spining MillRC-16M, 1117509Mismatch: 2.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.163364629652Kamal LimitedRC-38M, 0516831Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1731100011234Madni CNGRC-5M, 0753117Mismatch: 2.72 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1831100009635Zahid Jee TextileRC-11M, 0940592Mismatch: 1.16 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Hassaan131100006926Asif Textile Industries RC-3M, 0743244Mismatch: 6.46 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended231100011494Ali Hajwari Sizing IndRC-7M, 8826321Mismatch: 63.4 MCF (Uncorrected) EVC reading ahead of Mech. Counter. EVC is malfunctioning, thus generates extra pulses (more than 200 mcf/h) occasionally, without pressure variations. Rectification is recommended331100010060MB Sizing Chanchal walaRC-3M, 0540771Sticker at EVC Mechanical Index found Loose Suspected Replacement & flow proving of meter is recommended.431100011148Paracha Chemical, Chak No. 67/JBRC-7M, 007594Mismatch: 1.46 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Moreover, Oil Plug at Meter back body bottom found unsealed.Rectification is recommended531100009992Aysha Sizing -EVC dead.Rectification is recommended.632100009928Areeha Pvt Ltd. (C.P.)RC-3M, 0640787Hourly EVC Data could not be retrieved due to faulty EVC.Rectification is recommended732100007483Madina Enterprises RM-23000, 083071Severe Leakage observed at downstream Service Valve.Rectification is recommended831100006410Faisalabad Oil Refienry, ChiniotRC-11M, 0516751Mismatch: 210.8 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Replacement & flow proving of meter is recommended.931100012958Madina Pak CNG StationRVG G100, 75078910EVC dead.Rectification is recommended.1031100010907Dawood Exports Pvt Ltd RM-23000, 083085Mismatch: 34 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of Unbilled Volume is recommended1131100010219Amin CNG Filling RC-3M, 0843695Fault Volume: 7 MCF (Uncorrected)Booking of Unregistered Volume is recommended.1231100009129Imran Textile 9-Km -Consumer didn't allow the inspection of CMS. Action is required as per company policy1331100007349Azhar Corporation PvtRC-16M, 1117476Fault Volume: 2.8 MCF (Uncorrected)Booking of Unregistered Volume is recommended.1431100008803Z Gas Private LimitedRVG G100, 00031839EVC data could not be retrieved due to damaged EVC logs.Rectification is recommended.1531100010208Ch. & Company Attock PetroleumRC-5M, 1117201Fault Volume: 1193.6 MCF (Uncorrected) due to malfunctioning of Pressure Transducer.Booking of Unregistered Volume along with Replacement & Flow Proving of meter is recommended.1631100007606Sahib Textile (Pvt) LtdRC-16M, 0242136Mismatch: 4.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.175863590000AB Export (PVT) LTD 10-KM Sargodha Road FsdRC-11M, 0516782EVC Data not Retrieved (Connection problem)Rectification is recommended.1831100012613Commander CNGRC-5M, 1117218No company lock at CMS.Rectification is recommended.1931100013199Al Hamra FabricsRM-23000, 083210Mismatch: 219.9 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Fault Volume: 9.5 MCF (Uncorrected)Booking of unregistered volume is required along with replacement & Flow Proving of meter.2031100008278Sargodha Cloth Processing-Consumer didn't allow the inspection of CMS. Action is required as per company policy2131100007275Moon Textile IndustriesRC-11M, 0334314Mismatch: 549.7 MCF (Uncorrected) EVC Reading ahead. Replacement & Flow proving of meter is recommended
July ConsolidatedSr. No.Consumer No.Consumer NameMeter Type / No.AnomalyAction Required131100012527Arif Mehmood Malik Textile -Consumer didnt allow the inspection of CMS.Action is required as per company Policy.Consumer didnt allow the inspection of CMS.Action is required as per company Policy.231100008030Asgher Sizing RC 7M, 0516697EVC dead. Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended334100009571Gohar TextileRC-11M, 08219477EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.439100011614Millac Foods, JhangRC-5M, 0334244EVC dead. Battery Replacement of EVC is recommended.EVC dead. Battery Replacement of EVC is recommended.539100009480Shaker Gunj MillsRC-56M, 0516837Hourly & Daily data logs are not available in EVC Data. Re-configuration of EVC is recommendedHourly & Daily data logs are not available in EVC Data. Re-configuration of EVC is recommended6Davis EnergenRM-23000, 111065Mismatch: 13.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 13.15 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.739100013245Al Mubarik CNGIMRM 7M, 21000654Reduced consumption 40 % of connected load. Suspected, Replacement & Flow proving of meter is recommendedReduced consumption 40 % of connected load. Suspected, Replacement & Flow proving of meter is recommended831100005406Punjab CeramicsRW-3000, 14468129Fault Volume: 19.86 MCF (Uncorrected), EVC data shows 0% battery life. Booking of unregistered volume & Battery Replacement is recommended.Fault Volume: 19.86 MCF (Uncorrected), EVC data shows 0% battery life. Booking of unregistered volume & Battery Replacement is recommended.939100013029Al-Yousaf CNG3M, 0443409Fault Volume: 48.5 MCF (Uncorrected) Booking of unregistered volume is recommendedFault Volume: 48.5 MCF (Uncorrected) Booking of unregistered volume is recommended1034100007069Bilal IndustryRVG-G65,00029065EVC has stopped. Only Mechanical Counter is working. Suspected Tampered, Replacement & Flow Proving of Meter is recommendedEVC has stopped. Only Mechanical Counter is working. Suspected Tampered, Replacement & Flow Proving of Meter is recommended1139100012093Rawal CNG5M, 8918503(A-Series)Intermittent Flow Pattern observed in EVC Data Logs. Zero flows (for more than 5 hours) found after 5-6 operational hours. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.Intermittent Flow Pattern observed in EVC Data Logs. Zero flows (for more than 5 hours) found after 5-6 operational hours. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.1231100012022Bawa Jee CNG Filling StationConsumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.1334100006903Altaf IndustryRW-3000,48076CMS is without fence boundry and is inside premises.Outlet gauge was not working. Action is required as per company Policy.CMS is without fence boundry and is inside premises.Outlet gauge was not working. Action is required as per company Policy.1432100011527Sheraz (Rapid) CNGRC-5M, 0443425EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.1531100011364Kalash Pvt. LtdRC-7M, 0640625Flow rate often drops to Zero at mid night till morning. Leakage from regulator capillary. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.Flow rate often drops to Zero at mid night till morning. Leakage from regulator capillary. Suspected as Tampered. Replacement & Flow Proving of Meter is recommended.1631100011427Kay & EmmsRC-16M, 1117500EVC dead. Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended1734150012004Paris CNGRC-7M, 0311928EVC dead. Battery Replacement of EVC is recommendedEVC dead. Battery Replacement of EVC is recommended1834160011938Kamalia CNGRC-3M, 516408EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.1931100006410Faisalabad Oil Refienry, ChiniotRC-11M, 0516751EVC data not retrieved . Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.EVC data not retrieved . Mismatch: 20.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.207276116092AL-Raheem ProcessingIMRM 7M, 21000688Fault Volume: 4.122 MMCF (Uncorrected)Temperature values often exceeds to 212 F. Booking of unregistered volume & Calibration of Temperature Transducer is recommended.Fault Volume: 4.122 MMCF (Uncorrected)Temperature values often exceeds to 212 F. Booking of unregistered volume & Calibration of Temperature Transducer is recommended.2131100008234Rafique ProcessingRM-23000, 83225Removal attempts on EVC sticker. Suspected replacement & Flow proving of meter is recommendedRemoval attempts on EVC sticker. Suspected replacement & Flow proving of meter is recommended2231100007918Mian FabricsIMRM 16M, 2081418Reduced consumption 30 % of connected load. Some time zero flow is observed in non curtailment days. Suspected Replacement & Flow proving of meter is recommendedReduced consumption 30 % of connected load. Some time zero flow is observed in non curtailment days. Suspected Replacement & Flow proving of meter is recommended2331100008494Al- Kareem IndustryRC-16M, 0640665Mismatch: 3.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 3.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.2431100006197Tajammal Dyeing-Door lock of CMS is jammed, hence data retrival could not be done. Rectification is recommended.Door lock of CMS is jammed, hence data retrival could not be done. Rectification is recommended.2531100007253Sharif TextileRC-5M, 0743171Mismatch: 3.92 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops to Zero on nights. Replacement & Flow Proving of Meter is recommendedMismatch: 3.92 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops to Zero on nights. Replacement & Flow Proving of Meter is recommended2631100008085Nawab SizingRC-7M, 0312123Gas Leakage form adjustment bolt of Inlet Filter. Zero Flow is observed during night hours. Suspected Urgent rectification is recommended.Chances of gas pilferage exists through FilterGas Leakage form adjustment bolt of Inlet Filter. Zero Flow is observed during night hours. Suspected Urgent rectification is recommended.Chances of gas pilferage exists through Filter2731100008007Aala Processing-Consumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.2831100012970Mian CNGRC 5M, 0640597Mismatch: 2.63 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops on nights. Replacement & Flow Proving of Meter is recommendedMismatch: 2.63 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Flow often drops on nights. Replacement & Flow Proving of Meter is recommended2931100008126Rays HotelAL-425, 195227Gas leakage from Regulator before meter.Rectification is recommended.Gas leakage from Regulator before meter.Rectification is recommended.3031100008654Sajid Rehman TextileRC-5M, 0640877EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.3131100008353Fateh TextileRM-23000, 083072Mismatch: 15.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 15.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.324733985692Subhan Allah ProcessingRC-5M, 0940506Mismatch: 10.49 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 10.49 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.3331100009895General Chemicals1000A, 6032751EVC data not retrieved . Old Mercury version needs replacement with latest versions. Rectification is required.EVC data not retrieved . Old Mercury version needs replacement with latest versions. Rectification is required.3431100009613Zaheer BrothersRVG-G65, 00031478Gas leakage from Inlet Service Valve. Rectification is required.Gas leakage from Inlet Service Valve. Rectification is required.3531100013360Fazal -e- Rabbi TextileIMRM 7M, 20900893Mismatch: 6.07 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 6.07 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.3631100007048Syed DyeingRC-7M, 0311959Mismatch: 17.13MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.Mismatch: 17.13MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.3731100007190Dooab TextileRC-7M, 0312029Mismatch: 1.9MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 1.9MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.3831100012839Faiq CNGRC 11M, 9017353Fault Volume: 289.23 MCF (Uncorrected), due to malfunctioning of Pressure Transducer. Booking of unregistered volume & Calibration of Pressure Transducer is recommended.Fault Volume: 289.23 MCF (Uncorrected), due to malfunctioning of Pressure Transducer. Booking of unregistered volume & Calibration of Pressure Transducer is recommended.3931100009549Nishat Mills-3RC-38M, 0516832EVC data not retrieved . Mismatch: 5.4 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is required.EVC data not retrieved . Mismatch: 5.4 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is required.4031100000122Nishat Mills 1RC-56 M, 0334133Multiple reversals observed in EVC hourly data logs. Rectification is required.Multiple reversals observed in EVC hourly data logs. Rectification is required.4131100004265Lyallpur FoundaryRC-5M, 6040493Flow Rate drops to zero during night hours (12 pm ~ 8 am), along with reduced consumption. Suspected Replacement & Flow Proving of Meter is recommendedFlow Rate drops to zero during night hours (12 pm ~ 8 am), along with reduced consumption. Suspected Replacement & Flow Proving of Meter is recommended4231100012431Madni CNGIMRM 5M, 2081286EVC dead. Battery Replacement of EVC is recommended.EVC dead. Battery Replacement of EVC is recommended.4331100009107Al Ghafoor dyeing RC-5M, 0743233Flow Rate drops to zero during night hours . Suspected, Replacement & Flow Proving of Meter is recommendedFlow Rate drops to zero during night hours . Suspected, Replacement & Flow Proving of Meter is recommended4431100012226Lyallpur CNG-Consumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.4531100006379Madina Printing-Consumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.4631100006959Ittehad (unit-1)IMRM 16M, 2080744Mismatch: 4.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 4.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4731100005945Al-Noor TextileAL 1400, 5653705Mismatch: 22.24 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 22.24 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.4831100001697Lyallpur SizingRC-3M, 0948459EVC data not retrieved . Mismatch: 1.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is required.EVC data not retrieved . Mismatch: 1.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is required.4931100001705Jalandher sizingRC-5M, 0753252EVC data not retrieved . Rectification is required.EVC data not retrieved . Rectification is required.5031100004317Chanda Sizing-Consumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.5131100011041Kahloon CNGRC-3M, 0843434Hourly data logs are not available in EVC Memory. Re-configuration of EVC is recommended.Hourly data logs are not available in EVC Memory. Re-configuration of EVC is recommended.5231100000199National Silk MillsRM-23000, 111059Mismatch: 3.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 3.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.5331100010725National Silk Mills (C.P.)RC-11M, 0843957Mismatch: 40.06 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.Mismatch: 40.06 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.5431100011579Vega CNGRC-3M, 0843827EVC data not retrieved . Mismatch: 153.86 MCF (Uncorrected) EVC reading beind of Mech. Counter. Rectification is required & Booking of unbilled volume is recommended.EVC data not retrieved . Mismatch: 153.86 MCF (Uncorrected) EVC reading beind of Mech. Counter. Rectification is required & Booking of unbilled volume is recommended.5531100010071Abdul-Hameed BleachingRW-3000, 48043Flow Rate usually remains b/w 0.3 - 0.6 MCF/hr, though having small intervals of Flow Rate b/w 4-5 MCF/hr. Suspicion of Gas theft exists. A raid with C.P Team is underwayFlow Rate usually remains b/w 0.3 - 0.6 MCF/hr, though having small intervals of Flow Rate b/w 4-5 MCF/hr. Suspicion of Gas theft exists. A raid with C.P Team is underway5631100012293Harmain CNG, Chak No. 73/JB JhapalRC-11M, 0527133Fault Volume: 2081 m (Uncorrected). Booking of Unbilled Volume along with Replacement & Flow Proving of Meter is RecommendedFault Volume: 2081 m (Uncorrected). Booking of Unbilled Volume along with Replacement & Flow Proving of Meter is Recommended5731100004243Iftikhar Sizing RC-7M, 0940435Flow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with meter exist. Suspected, Replacement & Flow Proving of Meter is recommendedFlow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with meter exist. Suspected, Replacement & Flow Proving of Meter is recommended5831100009958Saad Sizing RVG G65, 00030440Reduced Flow Rate observed as per analysis of EVC Data. Suspicion of Fiddling with meter exist. Suspected, Replacement & Flow Proving of Meter is recommendedReduced Flow Rate observed as per analysis of EVC Data. Suspicion of Fiddling with meter exist. Suspected, Replacement & Flow Proving of Meter is recommended5931100013003Zulqarnain CNGIMRM 7M, 2081531Fault Volume: 4.3 MCF (Uncorrected). Booking of unbilled volume is recommended.Fault Volume: 4.3 MCF (Uncorrected). Booking of unbilled volume is recommended.6031100005990Mehboob Finishing Ayub ColonyRVG G65,75065032Flow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with Meter exist. Suspected, Replacement & Flow Proving of Meter is recommendedFlow Rate usually drops to Zero during night (22:00 to 06:00 PST), suspicion of fiddling with Meter exist. Suspected, Replacement & Flow Proving of Meter is recommended6131100006380Hamid Processing Factory-EVC data could not be retrieved due to bad configuration. Meter serial no. is not visible from plate. Replacement & Flow Proving of Meter is recommended along with re-configuration of EVC.EVC data could not be retrieved due to bad configuration. Meter serial no. is not visible from plate. Replacement & Flow Proving of Meter is recommended along with re-configuration of EVC.627443581207Abdullah Husnain DyeingRVG G65, 00031378Plastic Strip on EVC Mechanical Index found loose. Rectification is requiredPlastic Strip on EVC Mechanical Index found loose. Rectification is required6331100013768Talha Saad CNG, Chak No. 66IMRM 7M, 2080635Magnetic link at EVC (for Data Cable connection) is missing. Rectification is requiredMagnetic link at EVC (for Data Cable connection) is missing. Rectification is required6431100011557Sangam Petroleum Total PARCO outlet, Sudhuar by-passRVG G100, 00031779Regulator found damaged, Plastic Strip on EVC Mechanical Index found loose. Rectification is requiredRegulator found damaged, Plastic Strip on EVC Mechanical Index found loose. Rectification is required6531100012914City Gas Ways-II CNG Filling station, 74/JBIMRM-7M, 2081677Mismatch: 42.6 MCF (Uncorrected). Booking of Un-billed Volume along with Replacement & flow Proving of Meter is recommendedMismatch: 42.6 MCF (Uncorrected). Booking of Un-billed Volume along with Replacement & flow Proving of Meter is recommended6631100012248Al Rehman CNG, Chak No. 73/JB JhapalRC-5M, 0743260Plastic Strip on EVC Mechanical Index found loose. Rectification is requiredPlastic Strip on EVC Mechanical Index found loose. Rectification is required6731100012055Al Hasan Sizing Industries, Yousaf ChowkRC-5M, 0334206EVC data not could not be retrieved . Mismatch: 17.2 MCF (Uncorrected) EVC Reading ahead of Mech. Counter Reading. Replacement & Flow Proving of Meter is recommendedEVC data not could not be retrieved . Mismatch: 17.2 MCF (Uncorrected) EVC Reading ahead of Mech. Counter Reading. Replacement & Flow Proving of Meter is recommended6834100011459Qurai CNGIMRM 5M, 2080009Reduced consumption 30 % of connected load. Never goes to full load despite of Healthy pressure. Suspected, replacement & Flow proving of meter is recommendedReduced consumption 30 % of connected load. Never goes to full load despite of Healthy pressure. Suspected, replacement & Flow proving of meter is recommended6931100011397Lyallpur CNGRC-5M, 0753285Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 1.2 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.7034100013446Kahloon CNGRC-5M, 0516602Mismatch: 1.0 MCF (Uncorrected) EVC reading behind of Mech. Counter. Zero Flows observed during night hoursReplacement & Flow Proving of Meter is recommendedMismatch: 1.0 MCF (Uncorrected) EVC reading behind of Mech. Counter. Zero Flows observed during night hoursReplacement & Flow Proving of Meter is recommended7131100011580Akbar CNGRC-11M, 0527153EVC data not retrieved . (0% Battery life remaining). Rectification is recommended.EVC data not retrieved . (0% Battery life remaining). Rectification is recommended.7231100009743Blue Moon CNGRC-5M, 0743204EVC data not retrieved . (0% Battery life remaining). Rectification is recommended.EVC data not retrieved . (0% Battery life remaining). Rectification is recommended.7331100011955Laraib CNGRC-5M, 0753278Fault Volume: 1.2 MCF (Uncorrected), due to malfunctioning of Temperature Transducer (value sometime reaches to 159 F). Booking of unbilled volume & calibration of Pressure Transducer is recommended.Fault Volume: 1.2 MCF (Uncorrected), due to malfunctioning of Temperature Transducer (value sometime reaches to 159 F). Booking of unbilled volume & calibration of Pressure Transducer is recommended.7431100011665Touseef EnterprisesRC-7M, 0753342EVC dead. Rectification is recommended.EVC dead. Rectification is recommended.7531100009260Al Jamia SizingRVG G65, 00030425Mismatch: 418.6 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Replacement & Flow proving of meter is recommendedMismatch: 418.6 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Replacement & Flow proving of meter is recommended7631100011267City CNGIMRM-7M, 21000718Mismatch: 56.82 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.Mismatch: 56.82 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.777278384186Naveed EnterprisesIMRM 7M, 2081592Temperature probe not connected. Rectification is recommended.Temperature probe not connected. Rectification is recommended.7878214876480Mid Way CNGRC-5M, 0753186Reduced consumption 33 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommendedReduced consumption 33 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommended7931100000586United TextileRM-23000, 083231Hourly data logs are not available in EVC. Re-configuration of EVC is recommended.Hourly data logs are not available in EVC. Re-configuration of EVC is recommended.8031100006937Ahmed TextileRC-11M, 0940548Mismatch: 4.13 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 4.13 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.8131100010424Ali Raza SizingRC-5M, 0334213Reduced consumption 25 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommendedReduced consumption 25 % of connected load (never goes near full load), while line pressures are within healthy range. Suspected Replacement & Flow proving of meter is recommended8231100006658Serena HotelRC-5M, 0011452Mismatch: 5.03 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 5.03 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.8331100005536Qadria Callendering800-A, 715155Zero Flow is observed during night hours from 12:00 AM to 11:00 AMConsumer is to be kept under vigilence.Zero Flow is observed during night hours from 12:00 AM to 11:00 AMConsumer is to be kept under vigilence.8431100004759Shahdman CeramicsRW-3000, 14579363Mismatch: 2.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Zero Flow is observed throughoutFactory under maintenance. Consumer is to be kept under vigilence.Mismatch: 2.28 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Zero Flow is observed throughoutFactory under maintenance. Consumer is to be kept under vigilence.8531100006766Madni SizingRW-3000, 48829EVC dead. Rectification is recommended.EVC dead. Rectification is recommended.8631100010974Gulzar Dyeing CPRVG G65, 00029028Zero Flow is observed during night hours from 12:00 AM to 6:00 AM. Suspected Replacement & Flow proving of meter is recommendedZero Flow is observed during night hours from 12:00 AM to 6:00 AM. Suspected Replacement & Flow proving of meter is recommended8731100006346Gulzar DyeingRC-5M, 0444471EVC data not retrieved . Rectification is recommended.EVC data not retrieved . Rectification is recommended.8831100002850Insaf SizingRW-3000, 56400Temperature probe not connected. Rectification is recommended.Temperature probe not connected. Rectification is recommended.8931100006476Jelani textile-Consumer didnt allow the inspection of CMS. Action is required as per company Policy.Consumer didnt allow the inspection of CMS. Action is required as per company Policy.9031100013081Latif ExportRC-7M, 1117369Mismatch: 3.26 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Mismatch: 3.26 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.9131100004997New Sitara SizingRW-3000, 48026No company lock at CMS. Rectification is recommended.No company lock at CMS. Rectification is recommended.9231100000531Insaf TextileRC-16M, 1117480No company lock at CMS. Rectification is recommended.No company lock at CMS. Rectification is recommended.9331100010800Al Haq ExportRVG G65, 00030348Mismatch: 18 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 18 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.9431100012453Al Qasim CNGRC-5M, 8918454EVC dead. Rectification is recommended.EVC dead. Rectification is recommended.951556780290Fair Deal TextilesRC-7M, 0334257EVC data not retrieved . (connection problem) Rectification is recommended.EVC data not retrieved . (connection problem) Rectification is recommended.9631100011104Magna ProcessingIMRM 16M, 2081392Hourly data logs are not available in EVC. Re-configuration of EVC is recommended.Hourly data logs are not available in EVC. Re-configuration of EVC is recommended.973696917733Amar CNG StationIMRM 7M, 2081865 Removal attempts seems on EVC counter Sticker. Fault Volume: 12.99 MCF (Uncorrected). Suspected, Replacement & Flow proving of meter is recommendedRemoval attempts seems on EVC counter Sticker. Fault Volume: 12.99 MCF (Uncorrected). Suspected, Replacement & Flow proving of meter is recommended9831100009345Masood TextileRM-23000, 083243Mismatch: 3.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 3.7 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.993110009431Ishaq TextileRM-23000, 083073Mismatch: 708.5 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.Mismatch: 708.5 MCF (Uncorrected) EVC reading behind of Mech. Counter.Booking of unbilled volume is recommended.10031100008591Ibrahim FibersRM-38000, 0242153EVC data not retrieved . Rectification is recommended.EVC data not retrieved . Rectification is recommended.10131100011687Friends CNGRC-3M, 0843757Time difference; EVC lags behind 24 Min. Rectification is recommended.Time difference; EVC lags behind 24 Min. Rectification is recommended.10231100008609Bismillah TextileRC-38M,0516825 Mismatch: 2.9 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.Mismatch: 2.9 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommended.10331100010565Faisal Fabrics unit 2 (CP)RC-7M,0753379Mismatch: 8.68 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.Mismatch: 8.68 MCF (Uncorrected) EVC reading behind of Mech. Counter. Booking of unbilled volume is recommended.104888771511Bin Bashir TextileIMRM-11M, 2072896Fault Volume: 1.16 MCF (Uncorrected) Booking of unbilled volume is recommended.Fault Volume: 1.16 MCF (Uncorrected) Booking of unbilled volume is recommended.10531100010543Ittehad Textile-CMS lock jammed, due to which CMS checking & data retrival was not possible.Rectification is recommended.CMS lock jammed, due to which CMS checking & data retrival was not possible.Rectification is recommended.10631100008966Firdous Cloth MillsRC-16M, 1117533Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1078709049214Hassan Spining MillRC-16M, 1117509Mismatch: 2.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 2.1 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.1083364629652Kamal LimitedRC-38M, 0516831Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 1.0 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.10931100011234Madni CNGRC-5M, 0753117Mismatch: 2.72 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 2.72 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.11031100009635Zahid Jee TextileRC-11M, 0940592Mismatch: 1.16 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.Mismatch: 1.16 MCF (Uncorrected) EVC reading ahead of Mech. Counter.Rectification is recommended.11131100006926Asif Textile Industries RC-3M, 0743244Mismatch: 6.46 MCF (Uncorrected) EVC reading ahead of Mech. Counter. Rectification is recommendedMismatch: 6.46 MCF (Uncorrected) EVC r