Calibration Laboratory Since 2001 ISO/IEC 17025 NABL Accredited Lab Electro- Technical Time Thermal Temperature, Humidity Mechanical Mass, Volume, Dimension, Acoustics, Acceleration, Force Contact : Ahmedabad Textile Industry’s Research Association (ATIRA) Dr. Vikram Sarabhai Road, P. O. Ambawadi Vistar, Ahmedabad -380 015 Phone : (079) 26307921-22 Ext : 383 Website : www.atira.in email: [email protected]

Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

  • Upload
    others

  • View
    8

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Calibration Laboratory Since 2001

ISO/IEC 17025 NABL Accredited Lab

Electro-

Technical Time

Thermal Temperature,

Humidity

Mechanical Mass, Volume,

Dimension, Acoustics,

Acceleration, Force

Contact :

Ahmedabad Textile Industry’s Research Association (ATIRA)

Dr. Vikram Sarabhai Road, P. O. Ambawadi Vistar, Ahmedabad -380 015

Phone : (079) 26307921-22 Ext : 383

Website : www.atira.in

email: [email protected]

Page 2: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Textile and allied Industry

Dairy Industry

Pharmaceutical Companies

Engineering and Chemical Units

Clinical Research Organization

Coke Industries

Hospitals and Pathological Laboratories

Instrument Manufacturers & Suppliers

Paint Industry

Calibration Laboratories

Government Organizations like : ISRO, ONGC, IPR, GPCB

We are here to help to improve your quality.

Provide better & prompt responsive service.

Fully equipped calibration lab for onsite & at lab.

Maintain Quality system as per ISO/IEC 17025:2017.

International Standard methods adopted.

Delivered reliable & accurate results .

Ensuring confidentiality of results.

Well qualified & skilled staff.

Why Calibration from ATIRA

Page 3: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Scope

o Mass/Weights : Ranges 1 mg to 50 kg

o Weighing Balance : Ranges 1 mg to 50 kg

Calibration of Instruments

o Analytical Weighing balance, Weighing scales.

o F1 & M1 Class Weight box.

o CI Weights & others.

Mass

Scope

o Piston pipette : 10 μl to 1000 μl

o Volume : 1 ml to 1000 ml

o Viscous

Calibration of Instruments

o Micro Pipette, Measuring Cylinder, Rotameter, Infusion

Pump, Sand Content Tube, Gravity Cup, Flask, Beaker,

Burette, etc.

o Viscometer, Viscosity Cup, Viscosity Liquid, etc.

Volume & Viscosity

Page 4: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Scope o Pressure: 0 to 30 bar o Vacuum : 0 to -1 bar o Velocity : 0 to 35 m/s

Calibration of Instruments o B.P. apparatus, Oxygen Gauge, Pressure Gauge,

Vacuum Gauge, Digital Manometer, Pressure Switch, Pressure Transmitter, etc.

o Anemometer, Air Velocity Sensors etc.

Pressure & Velocity

Scope o Acoustics : 94 dB & 114 dB o Speed : 50 to 20000 RPM o Illumination

Calibration of Instruments o Sound Level meter. o Contact & Non-contact type Tachometer. o Lux meter, Holmium Filter, Didymium filter, o Validation of Sodium Light source, etc.

Acoustics, Speed & Illumination

Page 5: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Scope

o External Micrometer : 0 to 50 mm

o Vernire Caliper : 0 to 300 mm o Dial/ Wobble Gauge : 0 to 25 mm o Thickness Gauge : 0 to 25 mm o Depth Gauge : 0 to 30 mm o Measuring Scale : 0 to 600 mm o Plug Gauge : 0 to 50 mm o Mandrel : 0 to 50 mm

Calibration of Instruments o Micrometer, Vernier, Crimp, Cross Hatch, Film Applicator, Measuring

Tape, Slip Gauges, Dial Gauge, Stature Meter, S.S. Scale, Crimp meter, Mandrill, Height Scale, Sieves, Filter Pad, Angle Dekor, Crease Recovery Tester, GSM cutter, Wobble Gauge, GO NO GO Tester.

Dimension

Calibration of Instruments o Tarp Gauge, Tablet Hardness Tester, Proving Ring,

Push-Pull Indicator, Tensile Tester, Tension Meter, Torque Tester, Durometer.

Force

Page 6: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Standard : o Digital Density hydrometer.

Capability to calibrate

o Hydrometer, Butyrometer, Lactometer, Twaddle meter, Mud Balance

Density

Standard o pH / conductivity Buffers, Temperature sensor

Capability to calibrate

o pH / Conductivity meter

Standard o Breath alcohol simulator for 0.0% to 1.0% .

Capability to calibrate

o Breath analyzer .

Electro-Chemical

Alcohol Content

Page 7: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Scope o DC Voltage : 1 mV to 1000 V o DC Current : 100 μA to 10 A o Resistance : 1 Ω to 100 MΩ o AC Voltage : 100 mV to 1000 V o AC Current : 100 μA to 10 A o Frequency : 45 Hz to 100KHz o Capacitance : 10 nF to 1 mF o Temperature simulation : -200ºc to 600ºc o Time : 40 s to 24 hours

Calibration of Instruments o Digital Multi meter, Clamp Meter, Megger, Universal

calibrator, Resistor Bank, Earth Resistance tester. o Stop watch, Timer, Digital clock.

Electro-Technical

Page 8: Calibration Laboratory · Scope o Mass/Weights: Ranges 1mg to 50kg o Weighing Balance: Ranges 1mg to 50 kg Calibration of Instruments o Analytical Weighing balance, eighing scales

Scope o Temperature at Lab for sensors : -80º c to 1200º c o Temperature at site : -80º c to 1200º c o Humidity at site & Lab : 22% to 95% RH

Calibration of Instruments o Liquid glass thermometer. o RTD/ Thermo couple with or with out indicator. o Oven Muffle Furnace, Water bath, Deep freezer, COD,

BOD. o Thermo hygrometer, Humidity Chamber.

Thermal