Upload
wissam-jarmak
View
59
Download
5
Tags:
Embed Size (px)
DESCRIPTION
carrier
Citation preview
Econo Mode / EcoMode | The Economymode allows up to 25%energy saving.It operates at the highestpossible performance withthe least power consumption.
its can be set to function ortimer clock.
and assured with the new Carriernce, each unit is equipped with apor ts the unit's status to ensure fast
Up to three Operating Modes plus Auto Mode |There are three operating modes in every Carrier Air Conditioner: Cooling,Dehumidification, and Fan-Only. This ensures that you can control roomtemperature to within thatof your comfort zone allyear round. There is alsoAutomatic mode that allowsthe microprocessor tochoose how to achieve yourpreferred temperaturewithout human intervention.
sing unit has been
Single-Split Air-Con now comes in stylish, compact and economical units loaded with powerful
and private dwellings. With its Triple Clean Filter, which effectively kills bacteria, removes odour and
ured of clean and fresh air all the time. Enjoy the comfort you deserve!
Room temp.-Set temp.
+4
+1
-1
Cooling Mode Louver downward
Cooling Mode
Dry Mode
Fan only Mode
+4cThermostat
Setting
RoomTemp.
COOLING
Set
+2
+1
Set temp.is changed
Set temp.is changed
Time0Hr 1Hr 2Hr
Air Quality, More Energy Saving
w Useful Features & Functions
Triple Clean Filter | Threelayers of extra protection againstthe elements. This includes a dustcollecting filter, a static filter forsmaller dust particles, and a carbonfilter for trapping odours andbacteria. Our technology ensuresthat you are reminded every 40days that the filter needs cleaning.
Econo Mode / EcoMode | The Economymode allows up to 25%energy saving.It operates at the highestpossible performance withthe least power consumption.
12 hr On-Off Timer | Units can be set to function ordiscontinue function via a 12-hour timer clock.
Auto Diagnosis | Feel save and assured with the new CarrierAir Conditioner. For your convenience, each unit is equipped with asmart auto system diagnosis that repor ts the unit's status to ensure fastand effective repair.
Up to three Operating Modes plus Auto Mode |There are three operating modes in every Carrier Air Conditioner: Cooling,Dehumidification, and Fan-Only. This ensures that you can control roomtemperature to within thatof your comfort zone allyear round. There is alsoAutomatic mode that allowsthe microprocessor tochoose how to achieve yourpreferred temperaturewithout human intervention.
Continuous | Carrier condensing unit has beentested under the strict quality control system. Especially,A compressor, key component for air conditioners hasbeen tested over 3,500 hours as a life test.
Carrier Pure Dew Series Single-Split Air-Con now comes in stylish, compact and economical units loaded with powerfulfeatures, which is ideal for HDB and private dwellings. With its Triple Clean Filter, which effectively kills bacteria, removes odour and
prevents mould, you can be assured of clean and fresh air all the time. Enjoy the comfort you deserve!
3 - Stage Fan Speed Control
Room temp.-Set temp.
+4
+1
-1
Cooling Mode Louver downward
Cooling Mode
Dry Mode
Fan only Mode
+4c
+2c
High Medium Low
ThermostatSetting
RoomTemp.
Fan Speed
COOLING
Set
+2
+1
Set temp.is changed
Set temp.is changed
Time0Hr 1Hr 2Hr
Better Air Quality, More Energy Saving
New Useful Features & Functions
42CJR Series42CJR Series
Washable Front Panel | An easily removable frontpanel provides quick, effor tless cleaning.
Random Pitch Fan with Skew Blade | With our SkewBlade technology, out-put noise has been reduced to only 26 dB.
Multi-Bending Heat Exchanger | The bends onour new Heat Exchanger create greater surface area, whereas
heat can escape easier and the room is cooled faster with muchless energy.
42CJR010/38CJR010Amount of output:
1 HP (2.57 - 2.62 kw.)Recommended space:12-15 square meters.
42CJR013/38CJR013Amount of output:
1.5 HP (3.60 - 3.65 kw.)Recommended space:16-20 square meters.
42CJR018/38CJR018Amount of output:
2.0 HP (5.20 - 5.25 kw.)Recommended space:20-30 square meters.
42CJR024/38CJR024Amount of output:
3.0HP (6.40 - 6.45 kw.)Recommended space:30-35 square meters.
User friendly Remote Control | Wireless, trouble-free remote controls for maximumease of use.
Temperature Button ( ).....The set temperature is increased up to30oC......The set temperature is dropped down to19oC
START/STOP Button
Fan Speed Button (FAN)Press this button to select fan speed. when youselect AUTO, the fan speed is automaticallyadjusted according to the room temperature. Youcan also manually select the desire fan speed fromamong four settings.
(QUIET, LOW , MED , HIGH )
ECO Button (ECO)Press this button to start the ECO operation.
Auto Diagnosis (CHK)Service man pushes this button to check thelocation of a problem.
Cancel Button (CLR)Press this button to cancel ON timer and OFF
timer.
Reserve Button (SET)Press this button to reserve time settings.
AUTO COOL DRY AUTO FAN
Infrared Signal Emitter
Set Louver Button (FIX)Press this button to adjust the air flow
direction.
Auto Louver Button (SWING)Press this button to swing the horizontal
louver.Press the SWING button again to stopthe louver swinging.
Mode Select Button (MODE)Press this button to select a mode.Each time you press the button, a mode isselected in a sequence as following order.
Reset Button (RTS)Push this button when the batteries of theremote control have been replaced.
On Timer Button (ON)
Off Timer Button (OFF)
Temperature Button ( ).....The set temperature is increased up to30oC......The set temperature is dropped down to19oC
START/STOP Button
Fan Speed Button (FAN)Press this button to select fan speed. when youselect AUTO, the fan speed is automaticallyadjusted according to the room temperature. Youcan also manually select the desire fan speed fromamong four settings.
(QUIET, LOW , MED , HIGH )
ECO Button (ECO)Press this button to start the ECO operation.
Auto Diagnosis (CHK)Service man pushes this button to check thelocation of a problem.
Cancel Button (CLR)Press this button to cancel ON timer and OFF
timer.
Reserve Button (SET)Press this button to reserve time settings.
AUTO COOL DRY AUTO FAN
Infrared Signal Emitter
Set Louver Button (FIX)Press this button to adjust the air flow
direction.
Auto Louver Button (SWING)Press this button to swing the horizontal
louver.Press the SWING button again to stopthe louver swinging.
Mode Select Button (MODE)Press this button to select a mode.Each time you press the button, a mode isselected in a sequence as following order.
Reset Button (RTS)Push this button when the batteries of theremote control have been replaced.
On Timer Button (ON)
Off Timer Button (OFF)
Washable Front Panel | An easily removable frontpanel provides quick, effor tless cleaning.
Random Pitch Fan with Skew Blade | With our SkewBlade technology, out-put noise has been reduced to only 26 dB.
Multi-Bending Heat Exchanger | The bends onour new Heat Exchanger create greater surface area, whereas
heat can escape easier and the room is cooled faster with muchless energy.
42CJR010/38CJR010Amount of output:
1 HP (2.57 - 2.62 kw.)Recommended space:12-15 square meters.
42CJR013/38CJR013Amount of output:
1.5 HP (3.60 - 3.65 kw.)Recommended space:16-20 square meters.
42CJR018/38CJR018Amount of output:
2.0 HP (5.20 - 5.25 kw.)Recommended space:20-30 square meters.
42CJR024/38CJR024Amount of output:
3.0HP (6.40 - 6.45 kw.)Recommended space:30-35 square meters.
User friendly Remote Control | Wireless, trouble-free remote controls for maximumease of use.
3 Selectable fan speeds, plus Auto mode and Quiet mode | Choose yourdesired airflow among the three fan speeds offered by the new Carrier 42CJR series air-conditioner orselect the Auto fan-speed mode, which the air-conditioner choose optimal fan speed from High, Middle andLow, depending on the room temperature condition. For more choices, the Quiet fan-speed mode providesyou with most lowest fan speed at very low noise: 25dB.
Auto Restart | The indoor unit is equipped with an automatic restarting function which allows theunit to restart operating with the set operating conditions in the event of power supply being accidentallyshut down. The operation will resume without warning three minutes after power is restored.
Temperature Button ( ).....The set temperature is increased up to30oC......The set temperature is dropped down to19oC
START/STOP Button
Fan Speed Button (FAN)Press this button to select fan speed. when youselect AUTO, the fan speed is automaticallyadjusted according to the room temperature. Youcan also manually select the desire fan speed fromamong four settings.
(QUIET, LOW , MED , HIGH )
ECO Button (ECO)Press this button to start the ECO operation.
Auto Diagnosis (CHK)Service man pushes this button to check thelocation of a problem.
Cancel Button (CLR)Press this button to cancel ON timer and OFF
timer.
Reserve Button (SET)Press this button to reserve time settings.
AUTO COOL DRY AUTO FAN
Infrared Signal Emitter
Set Louver Button (FIX)Press this button to adjust the air flow
direction.
Auto Louver Button (SWING)Press this button to swing the horizontal
louver.Press the SWING button again to stopthe louver swinging.
Mode Select Button (MODE)Press this button to select a mode.Each time you press the button, a mode isselected in a sequence as following order.
Reset Button (RTS)Push this button when the batteries of theremote control have been replaced.
On Timer Button (ON)
Off Timer Button (OFF)
Temperature Button ( ).....The set temperature is increased up to30oC......The set temperature is dropped down to19oC
START/STOP Button
Fan Speed Button (FAN)Press this button to select fan speed. when youselect AUTO, the fan speed is automaticallyadjusted according to the room temperature. Youcan also manually select the desire fan speed fromamong four settings.
(QUIET, LOW , MED , HIGH )
ECO Button (ECO)Press this button to start the ECO operation.
Auto Diagnosis (CHK)Service man pushes this button to check thelocation of a problem.
Cancel Button (CLR)Press this button to cancel ON timer and OFF
timer.
Reserve Button (SET)Press this button to reserve time settings.
AUTO COOL DRY AUTO FAN
Infrared Signal Emitter
Set Louver Button (FIX)Press this button to adjust the air flow
direction.
Auto Louver Button (SWING)Press this button to swing the horizontal
louver.Press the SWING button again to stopthe louver swinging.
Mode Select Button (MODE)Press this button to select a mode.Each time you press the button, a mode isselected in a sequence as following order.
Reset Button (RTS)Push this button when the batteries of theremote control have been replaced.
On Timer Button (ON)
Off Timer Button (OFF)
Temperature Button ( ).....The set temperature is increased up to30oC......The set temperature is dropped down to19oC
START/STOP Button
Fan Speed Button (FAN)Press this button to select fan speed. when youselect AUTO, the fan speed is automaticallyadjusted according to the room temperature. Youcan also manually select the desire fan speed fromamong four settings.
(QUIET, LOW , MED , HIGH )
ECO Button (ECO)Press this button to start the ECO operation.
Auto Diagnosis (CHK)Service man pushes this button to check thelocation of a problem.
Cancel Button (CLR)Press this button to cancel ON timer and OFF
timer.
Reserve Button (SET)Press this button to reserve time settings.
AUTO COOL DRY AUTO FAN
Infrared Signal Emitter
Set Louver Button (FIX)Press this button to adjust the air flow
direction.
Auto Louver Button (SWING)Press this button to swing the horizontal
louver.Press the SWING button again to stopthe louver swinging.
Mode Select Button (MODE)Press this button to select a mode.Each time you press the button, a mode isselected in a sequence as following order.
Reset Button (RTS)Push this button when the batteries of theremote control have been replaced.
On Timer Button (ON)
Off Timer Button (OFF)
38CJR010,013 38CJR018,024
Manufacturer reserves the right to discontinue or change at any time, specifications or designs without notice & without incurring any obligations.The Manufacturer reserves the right to change any of the above contents, at its discretion.All Carrier products sold locally are covered under Carrier standard warranty. Please ensure that your warranty cards sent to Carrier Singapore (Pte) Limited for registration.Nominal capacity are based on indoor condition of (27 deg C DB, 19 deg C WB) and outdoor condition of 35 deg C DB.
Carrier Singapore (Pte) Ltd 28 Teban Garden Crescent, Singapore 608926 Tel: 65675522 Fax: 65676818Email: [email protected] Website: www.carrier.com.sg
To find out more about the Carrier Pure Dew Series, please call our cool-line at 64100369
Your Carrier Dealer
Model
Power Supply
Cooling Capacity*
Power Input
EER
Operating Current (RLA)**
Indoor Air Circulation
Noise
Dimension
Net weight
Refrigerant
Type of Compresor
Connections
DESCRIPTION
(V/ph/Hz)
(Kw)
(Watt)
(AMP.)
CFM
(dB)
(dB)
(dB)
(mm)
(mm)
(mm)
(kg)
High
Medium
Low
Height
Width
Depth
Outdoor
Indoor
Liquid
Suction
(inch)
(inch)
TYPE
38CJR010
42CJR010
2.57 - 2.62
800 - 850
10.95 - 10.51
3.75 - 3.73
370
44 / 39
- / 33
- / 26
550 / 275
780 / 790
270 / 208
30 / 10
3/8
R - 22
Rotary
1/4
1/2
38CJR024
42CJR024
6.40 - 6.45
2420 - 2510
9.01 - 8.87
10.73 - 11.30
560
56 / 45
- / 41
- / 37
690 /298
880 /998
310 / 208
58 / 12
5/8
38CJR018
42CJR018
5.20 - 5.25
1920 - 2000
9.21 - 8.91
9.45 - 9.70
440
51 / 42
- / 39
- / 35
538 / 298
780 / 998
300 / 208
46 / 12
38CJR013
42CJR013
3.60 - 3.65
1250 - 1290
9.79 - 9.62
5.75 - 5.60
370
47 / 41
- / 35
- / 31
550 / 275
780 / 790
270 / 208
35 / 10
HI-WALL
220 - 240/1/50
* C O O L I N G C A PAC I T Y B A S E D O N E N T E R I N G A I R T E M P. 8 0oF. D B / 6 7
oF. W B, A M B I E N T T E M P. 9 5
oF. D B
* * R L A = R AT E D L OA D A M P E R E
Speci f icat ions
THE CARRIER MAN CAN