798
Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Catalyst 2960 Switch Software Configuration Guide Cisco IOS Release 12.2(44)SE January 2008 Text Part Number: OL-8603-05

Catalyst 2960 Switch Software Configuration Guide - … · Catalyst 2960 Switch Software ... Security Features 1-8 ... Catalyst 2960 Switch Software Configuration Guide OL-8603-05

Embed Size (px)

Citation preview

  • Catalyst 2960 Switch Software Configuration GuideCisco IOS Release 12.2(44)SEJanuary 2008

    Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706 USAhttp://www.cisco.comTel: 408 526-4000

    800 553-NETS (6387)Fax: 408 527-0883

    Text Part Number: OL-8603-05

    http://www.cisco.com

  • THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS, INFORMATION, AND RECOMMENDATIONS IN THIS MANUAL ARE BELIEVED TO BE ACCURATE BUT ARE PRESENTED WITHOUT WARRANTY OF ANY KIND, EXPRESS OR IMPLIED. USERS MUST TAKE FULL RESPONSIBILITY FOR THEIR APPLICATION OF ANY PRODUCTS.

    THE SOFTWARE LICENSE AND LIMITED WARRANTY FOR THE ACCOMPANYING PRODUCT ARE SET FORTH IN THE INFORMATION PACKET THAT SHIPPED WITH THE PRODUCT AND ARE INCORPORATED HEREIN BY THIS REFERENCE. IF YOU ARE UNABLE TO LOCATE THE SOFTWARE LICENSE OR LIMITED WARRANTY, CONTACT YOUR CISCO REPRESENTATIVE FOR A COPY.

    The Cisco implementation of TCP header compression is an adaptation of a program developed by the University of California, Berkeley (UCB) as part of UCBs public domain version of the UNIX operating system. All rights reserved. Copyright 1981, Regents of the University of California.

    NOTWITHSTANDING ANY OTHER WARRANTY HEREIN, ALL DOCUMENT FILES AND SOFTWARE OF THESE SUPPLIERS ARE PROVIDED AS IS WITH ALL FAULTS. CISCO AND THE ABOVE-NAMED SUPPLIERS DISCLAIM ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THOSE OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OR ARISING FROM A COURSE OF DEALING, USAGE, OR TRADE PRACTICE.

    IN NO EVENT SHALL CISCO OR ITS SUPPLIERS BE LIABLE FOR ANY INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR LOSS OR DAMAGE TO DATA ARISING OUT OF THE USE OR INABILITY TO USE THIS MANUAL, EVEN IF CISCO OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.

    CCVP, the Cisco logo, and Welcome to the Human Network are trademarks of Cisco Systems, Inc.; Changing the Way We Work, Live, Play, and Learn is a service mark of Cisco Systems, Inc.; and Access Registrar, Aironet, Catalyst, CCDA, CCDP, CCIE, CCIP, CCNA, CCNP, CCSP, Cisco, the Cisco Certified Internetwork Expert logo, Cisco IOS, Cisco Press, Cisco Systems, Cisco Systems Capital, the Cisco Systems logo, Cisco Unity, Enterprise/Solver, EtherChannel, EtherFast, EtherSwitch, Fast Step, Follow Me Browsing, FormShare, GigaDrive, HomeLink, Internet Quotient, IOS, iPhone, IP/TV, iQ Expertise, the iQ logo, iQ Net Readiness Scorecard, iQuick Study, LightStream, Linksys, MeetingPlace, MGX, Networkers, Networking Academy, Network Registrar, PIX, ProConnect, ScriptShare, SMARTnet, StackWise, The Fastest Way to Increase Your Internet Quotient, and TransPath are registered trademarks of Cisco Systems, Inc. and/or its affiliates in the United States and certain other countries.

    All other trademarks mentioned in this document or Website are the property of their respective owners. The use of the word partner does not imply a partnership relationship between Cisco and any other company. (0711R)

    Any Internet Protocol (IP) addresses used in this document are not intended to be actual addresses. Any examples, command display output, and figures included in the document are shown for illustrative purposes only. Any use of actual IP addresses in illustrative content is unintentional and coincidental.

    Catalyst 2960 Switch Software Configuration GuideCopyright 20042008 Cisco Systems, Inc. All rights reserved.

  • OL-8603-05

    C O N T E N T S

    Preface xxxi

    Audience xxxi

    Purpose xxxi

    Conventions xxxii

    Related Publications xxxii

    Obtaining Documentation, Obtaining Support, and Security Guidelines xxxiv

    C H A P T E R 1 Overview 1-1

    Features 1-1Ease-of-Deployment and Ease-of-Use Features 1-2Performance Features 1-3Management Options 1-4Manageability Features 1-5Availability and Redundancy Features 1-6VLAN Features 1-7Security Features 1-8QoS and CoS Features 1-10Monitoring Features 1-11

    Default Settings After Initial Switch Configuration 1-12

    Network Configuration Examples 1-14Design Concepts for Using the Switch 1-14Small to Medium-Sized Network Using Catalyst 2960 Switches 1-18Long-Distance, High-Bandwidth Transport Configuration 1-19

    Where to Go Next 1-20

    C H A P T E R 2 Using the Command-Line Interface 2-1

    Understanding Command Modes 2-1

    Understanding the Help System 2-3

    Understanding Abbreviated Commands 2-4

    Understanding no and default Forms of Commands 2-4

    Understanding CLI Error Messages 2-5

    Using Configuration Logging 2-5

    iiiCatalyst 2960 Switch Software Configuration Guide

  • Contents

    Using Command History 2-6Changing the Command History Buffer Size 2-6Recalling Commands 2-6Disabling the Command History Feature 2-7

    Using Editing Features 2-7Enabling and Disabling Editing Features 2-7Editing Commands through Keystrokes 2-7Editing Command Lines that Wrap 2-9

    Searching and Filtering Output of show and more Commands 2-10

    Accessing the CLI 2-10Accessing the CLI through a Console Connection or through Telnet 2-10

    C H A P T E R 3 Assigning the Switch IP Address and Default Gateway 3-1

    Understanding the Boot Process 3-1

    Assigning Switch Information 3-2Default Switch Information 3-3Understanding DHCP-Based Autoconfiguration 3-3

    DHCP Client Request Process 3-4Understanding DHCP-based Autoconfiguration and Image Update 3-4

    DHCP Autoconfiguration 3-5DHCP Auto-Image Update 3-5Limitations and Restrictions 3-5

    Configuring DHCP-Based Autoconfiguration 3-6DHCP Server Configuration Guidelines 3-6Configuring the TFTP Server 3-7Configuring the DNS 3-7Configuring the Relay Device 3-7Obtaining Configuration Files 3-8Example Configuration 3-9

    Configuring the DHCP Auto Configuration and Image Update Features 3-11Configuring DHCP Autoconfiguration (Only Configuration File) 3-11Configuring DHCP Auto-Image Update (Configuration File and Image) 3-12Configuring the Client 3-13

    Manually Assigning IP Information 3-14

    Checking and Saving the Running Configuration 3-15

    Modifying the Startup Configuration 3-16Default Boot Configuration 3-16Automatically Downloading a Configuration File 3-16Specifying the Filename to Read and Write the System Configuration 3-16

    ivCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Booting Manually 3-17Booting a Specific Software Image 3-18Controlling Environment Variables 3-18

    Scheduling a Reload of the Software Image 3-20Configuring a Scheduled Reload 3-20Displaying Scheduled Reload Information 3-21

    C H A P T E R 4 Configuring Cisco IOS CNS Agents 4-1

    Understanding Cisco Configuration Engine Software 4-1Configuration Service 4-2Event Service 4-3

    NameSpace Mapper 4-3What You Should Know About the CNS IDs and Device Hostnames 4-3

    ConfigID 4-3DeviceID 4-4Hostname and DeviceID 4-4Using Hostname, DeviceID, and ConfigID 4-4

    Understanding Cisco IOS Agents 4-5Initial Configuration 4-5Incremental (Partial) Configuration 4-6Synchronized Configuration 4-6

    Configuring Cisco IOS Agents 4-6Enabling Automated CNS Configuration 4-6Enabling the CNS Event Agent 4-8Enabling the Cisco IOS CNS Agent 4-9

    Enabling an Initial Configuration 4-9Enabling a Partial Configuration 4-13

    Displaying CNS Configuration 4-14

    C H A P T E R 5 Clustering Switches 5-1

    Understanding Switch Clusters 5-1Cluster Command Switch Characteristics 5-3Standby Cluster Command Switch Characteristics 5-3Candidate Switch and Cluster Member Switch Characteristics 5-3

    Planning a Switch Cluster 5-4Automatic Discovery of Cluster Candidates and Members 5-4

    Discovery Through CDP Hops 5-5Discovery Through Non-CDP-Capable and Noncluster-Capable Devices 5-6Discovery Through Different VLANs 5-6

    vCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Discovery Through Different Management VLANs 5-7Discovery of Newly Installed Switches 5-8

    HSRP and Standby Cluster Command Switches 5-9Virtual IP Addresses 5-10Other Considerations for Cluster Standby Groups 5-10Automatic Recovery of Cluster Configuration 5-11

    IP Addresses 5-12Hostnames 5-12Passwords 5-12SNMP Community Strings 5-13TACACS+ and RADIUS 5-13LRE Profiles 5-13

    Using the CLI to Manage Switch Clusters 5-13Catalyst 1900 and Catalyst 2820 CLI Considerations 5-14

    Using SNMP to Manage Switch Clusters 5-14

    C H A P T E R 6 Administering the Switch 6-1

    Managing the System Time and Date 6-1Understanding the System Clock 6-1Understanding Network Time Protocol 6-2Configuring NTP 6-3

    Default NTP Configuration 6-4Configuring NTP Authentication 6-4Configuring NTP Associations 6-5Configuring NTP Broadcast Service 6-6Configuring NTP Access Restrictions 6-8Configuring the Source IP Address for NTP Packets 6-10Displaying the NTP Configuration 6-11

    Configuring Time and Date Manually 6-11Setting the System Clock 6-11Displaying the Time and Date Configuration 6-12Configuring the Time Zone 6-12Configuring Summer Time (Daylight Saving Time) 6-13

    Configuring a System Name and Prompt 6-14Default System Name and Prompt Configuration 6-15Configuring a System Name 6-15

    viCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Understanding DNS 6-15Default DNS Configuration 6-16Setting Up DNS 6-16Displaying the DNS Configuration 6-17

    Creating a Banner 6-17Default Banner Configuration 6-17Configuring a Message-of-the-Day Login Banner 6-18Configuring a Login Banner 6-19

    Managing the MAC Address Table 6-19Building the Address Table 6-20MAC Addresses and VLANs 6-20Default MAC Address Table Configuration 6-21Changing the Address Aging Time 6-21Removing Dynamic Address Entries 6-22Configuring MAC Address Notification Traps 6-22Adding and Removing Static Address Entries 6-24Configuring Unicast MAC Address Filtering 6-25Displaying Address Table Entries 6-26

    Managing the ARP Table 6-26

    C H A P T E R 7 Configuring SDM Templates 7-1

    Understanding the SDM Templates 7-1

    Configuring the Switch SDM Template 7-2Default SDM Template 7-2SDM Template Configuration Guidelines 7-2Setting the SDM Template 7-3

    .Displaying the SDM Templates 7-3

    C H A P T E R 8 Configuring Switch-Based Authentication 8-1

    Preventing Unauthorized Access to Your Switch 8-1

    Protecting Access to Privileged EXEC Commands 8-2Default Password and Privilege Level Configuration 8-2Setting or Changing a Static Enable Password 8-3Protecting Enable and Enable Secret Passwords with Encryption 8-3Disabling Password Recovery 8-5Setting a Telnet Password for a Terminal Line 8-6Configuring Username and Password Pairs 8-6

    viiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring Multiple Privilege Levels 8-7Setting the Privilege Level for a Command 8-8Changing the Default Privilege Level for Lines 8-9Logging into and Exiting a Privilege Level 8-9

    Controlling Switch Access with TACACS+ 8-10Understanding TACACS+ 8-10TACACS+ Operation 8-12Configuring TACACS+ 8-12

    Default TACACS+ Configuration 8-13Identifying the TACACS+ Server Host and Setting the Authentication Key 8-13Configuring TACACS+ Login Authentication 8-14Configuring TACACS+ Authorization for Privileged EXEC Access and Network Services 8-16Starting TACACS+ Accounting 8-17

    Displaying the TACACS+ Configuration 8-17

    Controlling Switch Access with RADIUS 8-17Understanding RADIUS 8-18RADIUS Operation 8-19Configuring RADIUS 8-19

    Default RADIUS Configuration 8-20Identifying the RADIUS Server Host 8-20Configuring RADIUS Login Authentication 8-23Defining AAA Server Groups 8-25Configuring RADIUS Authorization for User Privileged Access and Network Services 8-27Starting RADIUS Accounting 8-28Configuring Settings for All RADIUS Servers 8-29Configuring the Switch to Use Vendor-Specific RADIUS Attributes 8-29Configuring the Switch for Vendor-Proprietary RADIUS Server Communication 8-31

    Displaying the RADIUS Configuration 8-31

    Configuring the Switch for Local Authentication and Authorization 8-32

    Configuring the Switch for Secure Shell 8-33Understanding SSH 8-33

    SSH Servers, Integrated Clients, and Supported Versions 8-34Limitations 8-34

    Configuring SSH 8-34Configuration Guidelines 8-35Setting Up the Switch to Run SSH 8-35Configuring the SSH Server 8-36

    Displaying the SSH Configuration and Status 8-37

    Configuring the Switch for Secure Socket Layer HTTP 8-37

    viiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Understanding Secure HTTP Servers and Clients 8-38Certificate Authority Trustpoints 8-38CipherSuites 8-39

    Configuring Secure HTTP Servers and Clients 8-40Default SSL Configuration 8-40SSL Configuration Guidelines 8-40Configuring a CA Trustpoint 8-40Configuring the Secure HTTP Server 8-41Configuring the Secure HTTP Client 8-43

    Displaying Secure HTTP Server and Client Status 8-44

    Configuring the Switch for Secure Copy Protocol 8-44Information About Secure Copy 8-44

    C H A P T E R 9 Configuring IEEE 802.1x Port-Based Authentication 9-1

    Understanding IEEE 802.1x Port-Based Authentication 9-1Device Roles 9-3Authentication Process 9-4Authentication Initiation and Message Exchange 9-6Ports in Authorized and Unauthorized States 9-8IEEE 802.1x Host Mode 9-8IEEE 802.1x Accounting 9-9IEEE 802.1x Accounting Attribute-Value Pairs 9-9Using 802.1x Readiness Check 9-10Using IEEE 802.1x Authentication with VLAN Assignment 9-11Using IEEE 802.1x Authentication with Guest VLAN 9-12Using IEEE 802.1x Authentication with Restricted VLAN 9-13Using IEEE 802.1x Authentication with Inaccessible Authentication Bypass 9-14Using IEEE 802.1x Authentication with Voice VLAN Ports 9-15Using IEEE 802.1x Authentication with Port Security 9-16Using IEEE 802.1x Authentication with Wake-on-LAN 9-17Using IEEE 802.1x Authentication with MAC Authentication Bypass 9-17Using Network Admission Control Layer 2 IEEE 802.1x Validation 9-19Using Web Authentication 9-19

    Web Authentication with Automatic MAC Check 9-20

    Configuring IEEE 802.1x Authentication 9-20Default IEEE 802.1x Authentication Configuration 9-21IEEE 802.1x Authentication Configuration Guidelines 9-22

    IEEE 802.1x Authentication 9-22

    ixCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    VLAN Assignment, Guest VLAN, Restricted VLAN, and Inaccessible Authentication Bypass 9-23MAC Authentication Bypass 9-24

    Upgrading from a Previous Software Release 9-24Configuring 802.1x Readiness Check 9-24Configuring IEEE 802.1x Authentication 9-25Configuring the Switch-to-RADIUS-Server Communication 9-26Configuring the Host Mode 9-28Configuring Periodic Re-Authentication 9-28Manually Re-Authenticating a Client Connected to a Port 9-29Changing the Quiet Period 9-29Changing the Switch-to-Client Retransmission Time 9-30Setting the Switch-to-Client Frame-Retransmission Number 9-31Setting the Re-Authentication Number 9-31Configuring IEEE 802.1x Accounting 9-32Configuring a Guest VLAN 9-33Configuring a Restricted VLAN 9-34Configuring the Inaccessible Authentication Bypass Feature 9-36Configuring IEEE 802.1x Authentication with WoL 9-38Configuring MAC Authentication Bypass 9-39Configuring NAC Layer 2 IEEE 802.1x Validation 9-40Configuring Web Authentication 9-41Disabling IEEE 802.1x Authentication on the Port 9-43Resetting the IEEE 802.1x Authentication Configuration to the Default Values 9-44

    Displaying IEEE 802.1x Statistics and Status 9-44

    C H A P T E R 10 Configuring Interface Characteristics 10-1

    Understanding Interface Types 10-1Port-Based VLANs 10-2Switch Ports 10-2

    Access Ports 10-2Trunk Ports 10-3

    EtherChannel Port Groups 10-3Dual-Purpose Uplink Ports 10-4Connecting Interfaces 10-4

    Using Interface Configuration Mode 10-5Procedures for Configuring Interfaces 10-5Configuring a Range of Interfaces 10-6Configuring and Using Interface Range Macros 10-7

    xCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring Ethernet Interfaces 10-9Default Ethernet Interface Configuration 10-9Setting the Type of a Dual-Purpose Uplink Port 10-10Configuring Interface Speed and Duplex Mode 10-12

    Speed and Duplex Configuration Guidelines 10-12Setting the Interface Speed and Duplex Parameters 10-13

    Configuring IEEE 802.3x Flow Control 10-14Configuring Auto-MDIX on an Interface 10-15 Adding a Description for an Interface 10-16

    Configuring the System MTU 10-16

    Monitoring and Maintaining the Interfaces 10-18Monitoring Interface Status 10-18Clearing and Resetting Interfaces and Counters 10-19Shutting Down and Restarting the Interface 10-19

    C H A P T E R 11 Configuring Smartports Macros 11-1

    Understanding Smartports Macros 11-1

    Configuring Smartports Macros 11-2Default Smartports Macro Configuration 11-2Smartports Macro Configuration Guidelines 11-2Creating Smartports Macros 11-4Applying Smartports Macros 11-5Applying Cisco-Default Smartports Macros 11-6

    Displaying Smartports Macros 11-8

    C H A P T E R 12 Configuring VLANs 12-1

    Understanding VLANs 12-1Supported VLANs 12-2VLAN Port Membership Modes 12-3

    Configuring Normal-Range VLANs 12-4Token Ring VLANs 12-5Normal-Range VLAN Configuration Guidelines 12-5VLAN Configuration Mode Options 12-6

    VLAN Configuration in config-vlan Mode 12-6VLAN Configuration in VLAN Database Configuration Mode 12-6

    Saving VLAN Configuration 12-7Default Ethernet VLAN Configuration 12-7Creating or Modifying an Ethernet VLAN 12-8

    xiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Deleting a VLAN 12-10Assigning Static-Access Ports to a VLAN 12-10

    Configuring Extended-Range VLANs 12-11Default VLAN Configuration 12-12Extended-Range VLAN Configuration Guidelines 12-12Creating an Extended-Range VLAN 12-12

    Displaying VLANs 12-14

    Configuring VLAN Trunks 12-14Trunking Overview 12-14

    IEEE 802.1Q Configuration Considerations 12-15Default Layer 2 Ethernet Interface VLAN Configuration 12-16Configuring an Ethernet Interface as a Trunk Port 12-16

    Interaction with Other Features 12-16Configuring a Trunk Port 12-17Defining the Allowed VLANs on a Trunk 12-18Changing the Pruning-Eligible List 12-19Configuring the Native VLAN for Untagged Traffic 12-20

    Configuring Trunk Ports for Load Sharing 12-20Load Sharing Using STP Port Priorities 12-21Load Sharing Using STP Path Cost 12-22

    Configuring VMPS 12-24Understanding VMPS 12-24

    Dynamic-Access Port VLAN Membership 12-25Default VMPS Client Configuration 12-25VMPS Configuration Guidelines 12-25Configuring the VMPS Client 12-26

    Entering the IP Address of the VMPS 12-26Configuring Dynamic-Access Ports on VMPS Clients 12-27Reconfirming VLAN Memberships 12-27Changing the Reconfirmation Interval 12-27Changing the Retry Count 12-28

    Monitoring the VMPS 12-28Troubleshooting Dynamic-Access Port VLAN Membership 12-29VMPS Configuration Example 12-29

    C H A P T E R 13 Configuring VTP 13-1

    Understanding VTP 13-1The VTP Domain 13-2VTP Modes 13-3

    xiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    VTP Advertisements 13-3VTP Version 2 13-4VTP Pruning 13-4

    Configuring VTP 13-6Default VTP Configuration 13-6VTP Configuration Options 13-7

    VTP Configuration in Global Configuration Mode 13-7VTP Configuration in VLAN Database Configuration Mode 13-7

    VTP Configuration Guidelines 13-8Domain Names 13-8Passwords 13-8VTP Version 13-8Configuration Requirements 13-9

    Configuring a VTP Server 13-9Configuring a VTP Client 13-11Disabling VTP (VTP Transparent Mode) 13-12Enabling VTP Version 2 13-13Enabling VTP Pruning 13-14Adding a VTP Client Switch to a VTP Domain 13-14

    Monitoring VTP 13-16

    C H A P T E R 14 Configuring Voice VLAN 14-1

    Understanding Voice VLAN 14-1Cisco IP Phone Voice Traffic 14-2Cisco IP Phone Data Traffic 14-2

    Configuring Voice VLAN 14-3Default Voice VLAN Configuration 14-3Voice VLAN Configuration Guidelines 14-3Configuring a Port Connected to a Cisco 7960 IP Phone 14-4

    Configuring Cisco IP Phone Voice Traffic 14-4Configuring the Priority of Incoming Data Frames 14-6

    Displaying Voice VLAN 14-6

    C H A P T E R 15 Configuring STP 15-1

    Understanding Spanning-Tree Features 15-1STP Overview 15-2Spanning-Tree Topology and BPDUs 15-3Bridge ID, Switch Priority, and Extended System ID 15-4Spanning-Tree Interface States 15-4

    xiiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Blocking State 15-6Listening State 15-6Learning State 15-6Forwarding State 15-6Disabled State 15-7

    How a Switch or Port Becomes the Root Switch or Root Port 15-7Spanning Tree and Redundant Connectivity 15-8Spanning-Tree Address Management 15-8Accelerated Aging to Retain Connectivity 15-8Spanning-Tree Modes and Protocols 15-9Supported Spanning-Tree Instances 15-9Spanning-Tree Interoperability and Backward Compatibility 15-10STP and IEEE 802.1Q Trunks 15-10

    Configuring Spanning-Tree Features 15-10Default Spanning-Tree Configuration 15-11Spanning-Tree Configuration Guidelines 15-12Changing the Spanning-Tree Mode. 15-13Disabling Spanning Tree 15-14Configuring the Root Switch 15-14Configuring a Secondary Root Switch 15-16Configuring Port Priority 15-16Configuring Path Cost 15-18Configuring the Switch Priority of a VLAN 15-19Configuring Spanning-Tree Timers 15-20

    Configuring the Hello Time 15-20Configuring the Forwarding-Delay Time for a VLAN 15-21Configuring the Maximum-Aging Time for a VLAN 15-21Configuring the Transmit Hold-Count 15-22

    Displaying the Spanning-Tree Status 15-22

    C H A P T E R 16 Configuring MSTP 16-1

    Understanding MSTP 16-2Multiple Spanning-Tree Regions 16-2IST, CIST, and CST 16-3

    Operations Within an MST Region 16-3Operations Between MST Regions 16-4IEEE 802.1s Terminology 16-5

    Hop Count 16-5Boundary Ports 16-6

    xivCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    IEEE 802.1s Implementation 16-6Port Role Naming Change 16-7Interoperation Between Legacy and Standard Switches 16-7Detecting Unidirectional Link Failure 16-8

    Interoperability with IEEE 802.1D STP 16-8

    Understanding RSTP 16-8Port Roles and the Active Topology 16-9Rapid Convergence 16-10Synchronization of Port Roles 16-11Bridge Protocol Data Unit Format and Processing 16-12

    Processing Superior BPDU Information 16-13Processing Inferior BPDU Information 16-13

    Topology Changes 16-13

    Configuring MSTP Features 16-14Default MSTP Configuration 16-14MSTP Configuration Guidelines 16-15Specifying the MST Region Configuration and Enabling MSTP 16-16Configuring the Root Switch 16-17Configuring a Secondary Root Switch 16-18Configuring Port Priority 16-19Configuring Path Cost 16-20Configuring the Switch Priority 16-21Configuring the Hello Time 16-22Configuring the Forwarding-Delay Time 16-23Configuring the Maximum-Aging Time 16-23Configuring the Maximum-Hop Count 16-24Specifying the Link Type to Ensure Rapid Transitions 16-24Designating the Neighbor Type 16-25Restarting the Protocol Migration Process 16-25

    Displaying the MST Configuration and Status 16-26

    C H A P T E R 17 Configuring Optional Spanning-Tree Features 17-1

    Understanding Optional Spanning-Tree Features 17-1Understanding Port Fast 17-2Understanding BPDU Guard 17-2Understanding BPDU Filtering 17-3Understanding UplinkFast 17-3Understanding BackboneFast 17-5Understanding EtherChannel Guard 17-7

    xvCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Understanding Root Guard 17-8Understanding Loop Guard 17-9

    Configuring Optional Spanning-Tree Features 17-9Default Optional Spanning-Tree Configuration 17-9Optional Spanning-Tree Configuration Guidelines 17-10Enabling Port Fast 17-10Enabling BPDU Guard 17-11Enabling BPDU Filtering 17-12Enabling UplinkFast for Use with Redundant Links 17-13Enabling BackboneFast 17-13Enabling EtherChannel Guard 17-14Enabling Root Guard 17-15Enabling Loop Guard 17-15

    Displaying the Spanning-Tree Status 17-16

    C H A P T E R 18 Configuring Flex Links and the MAC Address-Table Move Update Feature 18-1

    Understanding Flex Links and the MAC Address-Table Move Update 18-1Flex Links 18-2VLAN Flex Link Load Balancing and Support 18-2Flex Link Multicast Fast Convergence 18-3

    Learning the Other Flex Link Port as the mrouter Port 18-3Generating IGMP Reports 18-4Leaking IGMP Reports 18-4

    MAC Address-Table Move Update 18-6

    Configuring Flex Links and the MAC Address-Table Move Update 18-7Default Configuration 18-8Configuration Guidelines 18-8Configuring Flex Links 18-9Configuring VLAN Load Balancing on Flex Links 18-11Configuring the MAC Address-Table Move Update Feature 18-12

    Monitoring Flex Links and the MAC Address-Table Move Update 18-14

    C H A P T E R 19 Configuring DHCP Features 19-1

    Understanding DHCP Features 19-1DHCP Server 19-2DHCP Relay Agent 19-2DHCP Snooping 19-2Option-82 Data Insertion 19-3DHCP Snooping Binding Database 19-5

    xviCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring DHCP Features 19-6Default DHCP Configuration 19-7DHCP Snooping Configuration Guidelines 19-7Configuring the DHCP Relay Agent 19-8Enabling DHCP Snooping and Option 82 19-9Enabling the Cisco IOS DHCP Server Database 19-10Enabling the DHCP Snooping Binding Database Agent 19-11

    Displaying DHCP Snooping Information 19-12

    C H A P T E R 20 Configuring IGMP Snooping and MVR 20-1

    Understanding IGMP Snooping 20-1IGMP Versions 20-2Joining a Multicast Group 20-3Leaving a Multicast Group 20-5Immediate Leave 20-5IGMP Configurable-Leave Timer 20-5IGMP Report Suppression 20-6

    Configuring IGMP Snooping 20-6Default IGMP Snooping Configuration 20-6Enabling or Disabling IGMP Snooping 20-7Setting the Snooping Method 20-8Configuring a Multicast Router Port 20-9Configuring a Host Statically to Join a Group 20-9Enabling IGMP Immediate Leave 20-10Configuring the IGMP Leave Timer 20-10Configuring TCN-Related Commands 20-11

    Controlling the Multicast Flooding Time After a TCN Event 20-11Recovering from Flood Mode 20-12Disabling Multicast Flooding During a TCN Event 20-12

    Configuring the IGMP Snooping Querier 20-13Disabling IGMP Report Suppression 20-14

    Displaying IGMP Snooping Information 20-15

    Understanding Multicast VLAN Registration 20-16Using MVR in a Multicast Television Application 20-17

    Configuring MVR 20-19Default MVR Configuration 20-19MVR Configuration Guidelines and Limitations 20-19Configuring MVR Global Parameters 20-20Configuring MVR Interfaces 20-21

    xviiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Displaying MVR Information 20-22

    Configuring IGMP Filtering and Throttling 20-23Default IGMP Filtering and Throttling Configuration 20-24Configuring IGMP Profiles 20-24Applying IGMP Profiles 20-25Setting the Maximum Number of IGMP Groups 20-26Configuring the IGMP Throttling Action 20-26

    Displaying IGMP Filtering and Throttling Configuration 20-28

    C H A P T E R 21 Configuring Port-Based Traffic Control 21-1

    Configuring Storm Control 21-1Understanding Storm Control 21-1Default Storm Control Configuration 21-3Configuring Storm Control and Threshold Levels 21-3Configuring Small-Frame Arrival Rate 21-5

    Configuring Protected Ports 21-6Default Protected Port Configuration 21-6Protected Port Configuration Guidelines 21-7Configuring a Protected Port 21-7

    Configuring Port Blocking 21-7Default Port Blocking Configuration 21-7Blocking Flooded Traffic on an Interface 21-8

    Configuring Port Security 21-8Understanding Port Security 21-9

    Secure MAC Addresses 21-9Security Violations 21-10

    Default Port Security Configuration 21-11Port Security Configuration Guidelines 21-11Enabling and Configuring Port Security 21-12Enabling and Configuring Port Security Aging 21-17

    Displaying Port-Based Traffic Control Settings 21-18

    C H A P T E R 22 Configuring CDP 22-1

    Understanding CDP 22-1

    Configuring CDP 22-2Default CDP Configuration 22-2Configuring the CDP Characteristics 22-2Disabling and Enabling CDP 22-3

    xviiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Disabling and Enabling CDP on an Interface 22-4

    Monitoring and Maintaining CDP 22-4

    C H A P T E R 23 Configuring LLDP and LLDP-MED 23-1

    Understanding LLDP and LLDP-MED 23-1Understanding LLDP 23-1Understanding LLDP-MED 23-2

    Configuring LLDP and LLDP-MED 23-3Default LLDP Configuration 23-3Configuring LLDP Characteristics 23-4Disabling and Enabling LLDP Globally 23-5Disabling and Enabling LLDP on an Interface 23-5Configuring LLDP-MED TLVs 23-6Monitoring and Maintaining LLDP and LLDP-MED 23-7

    C H A P T E R 24 Configuring UDLD 24-1

    Understanding UDLD 24-1Modes of Operation 24-1Methods to Detect Unidirectional Links 24-2

    Configuring UDLD 24-3Default UDLD Configuration 24-4Configuration Guidelines 24-4Enabling UDLD Globally 24-5Enabling UDLD on an Interface 24-5Resetting an Interface Disabled by UDLD 24-6

    Displaying UDLD Status 24-6

    C H A P T E R 25 Configuring SPAN and RSPAN 25-1

    Understanding SPAN and RSPAN 25-1Local SPAN 25-2Remote SPAN 25-2SPAN and RSPAN Concepts and Terminology 25-3

    SPAN Sessions 25-3Monitored Traffic 25-4Source Ports 25-5Source VLANs 25-6VLAN Filtering 25-6Destination Port 25-6RSPAN VLAN 25-7

    xixCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    SPAN and RSPAN Interaction with Other Features 25-8

    Configuring SPAN and RSPAN 25-9Default SPAN and RSPAN Configuration 25-9Configuring Local SPAN 25-9

    SPAN Configuration Guidelines 25-10Creating a Local SPAN Session 25-10Creating a Local SPAN Session and Configuring Incoming Traffic 25-13Specifying VLANs to Filter 25-14

    Configuring RSPAN 25-15RSPAN Configuration Guidelines 25-16Configuring a VLAN as an RSPAN VLAN 25-16Creating an RSPAN Source Session 25-17Creating an RSPAN Destination Session 25-19Creating an RSPAN Destination Session and Configuring Incoming Traffic 25-20Specifying VLANs to Filter 25-21

    Displaying SPAN and RSPAN Status 25-22

    C H A P T E R 26 Configuring RMON 26-1

    Understanding RMON 26-1

    Configuring RMON 26-2Default RMON Configuration 26-3Configuring RMON Alarms and Events 26-3Collecting Group History Statistics on an Interface 26-5Collecting Group Ethernet Statistics on an Interface 26-5

    Displaying RMON Status 26-6

    C H A P T E R 27 Configuring System Message Logging 27-1

    Understanding System Message Logging 27-1

    Configuring System Message Logging 27-2System Log Message Format 27-2Default System Message Logging Configuration 27-3Disabling Message Logging 27-4Setting the Message Display Destination Device 27-5Synchronizing Log Messages 27-6Enabling and Disabling Time Stamps on Log Messages 27-7Enabling and Disabling Sequence Numbers in Log Messages 27-8Defining the Message Severity Level 27-8Limiting Syslog Messages Sent to the History Table and to SNMP 27-10Enabling the Configuration-Change Logger 27-10

    xxCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring UNIX Syslog Servers 27-12Logging Messages to a UNIX Syslog Daemon 27-12Configuring the UNIX System Logging Facility 27-12

    Displaying the Logging Configuration 27-13

    C H A P T E R 28 Configuring SNMP 28-1

    Understanding SNMP 28-1SNMP Versions 28-2SNMP Manager Functions 28-3SNMP Agent Functions 28-4SNMP Community Strings 28-4Using SNMP to Access MIB Variables 28-4SNMP Notifications 28-5SNMP ifIndex MIB Object Values 28-5

    Configuring SNMP 28-6Default SNMP Configuration 28-6SNMP Configuration Guidelines 28-7Disabling the SNMP Agent 28-7Configuring Community Strings 28-8Configuring SNMP Groups and Users 28-9Configuring SNMP Notifications 28-11Setting the Agent Contact and Location Information 28-14Limiting TFTP Servers Used Through SNMP 28-15SNMP Examples 28-16

    Displaying SNMP Status 28-17

    C H A P T E R 29 Configuring Network Security with ACLs 29-19

    Understanding ACLs 29-19Port ACLs 29-20Handling Fragmented and Unfragmented Traffic 29-21

    Configuring IPv4 ACLs 29-22Creating Standard and Extended IPv4 ACLs 29-23

    Access List Numbers 29-24Creating a Numbered Standard ACL 29-25Creating a Numbered Extended ACL 29-26Resequencing ACEs in an ACL 29-30Creating Named Standard and Extended ACLs 29-30Using Time Ranges with ACLs 29-32Including Comments in ACLs 29-33

    xxiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Applying an IPv4 ACL to a Terminal Line 29-34Applying an IPv4 ACL to an Interface 29-34Hardware and Software Treatment of IP ACLs 29-35IPv4 ACL Configuration Examples 29-35

    Numbered ACLs 29-36Extended ACLs 29-36Named ACLs 29-36Time Range Applied to an IP ACL 29-37Commented IP ACL Entries 29-37

    Creating Named MAC Extended ACLs 29-37Applying a MAC ACL to a Layer 2 Interface 29-39

    Displaying IPv4 ACL Configuration 29-40

    C H A P T E R 30 Configuring Cisco IOS IP SLAs Operations 30-1

    Understanding Cisco IOS IP SLAs 30-1Using Cisco IOS IP SLAs to Measure Network Performance 30-3IP SLAs Responder and IP SLAs Control Protocol 30-4Response Time Computation for IP SLAs 30-4

    Configuring IP SLAs Operations 30-5Default Configuration 30-5Configuration Guidelines 30-5Configuring the IP SLAs Responder 30-6

    Monitoring IP SLAs Operations 30-7

    C H A P T E R 31 Configuring QoS 31-1

    Understanding QoS 31-2Basic QoS Model 31-3Classification 31-5

    Classification Based on QoS ACLs 31-6Classification Based on Class Maps and Policy Maps 31-7

    Policing and Marking 31-8Policing on Physical Ports 31-8

    Mapping Tables 31-10Queueing and Scheduling Overview 31-11

    Weighted Tail Drop 31-11SRR Shaping and Sharing 31-12Queueing and Scheduling on Ingress Queues 31-13Queueing and Scheduling on Egress Queues 31-15

    Packet Modification 31-17

    xxiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring Auto-QoS 31-18Generated Auto-QoS Configuration 31-19Effects of Auto-QoS on the Configuration 31-23Auto-QoS Configuration Guidelines 31-23Enabling Auto-QoS for VoIP 31-24Auto-QoS Configuration Example 31-26

    Displaying Auto-QoS Information 31-28

    Configuring Standard QoS 31-28Default Standard QoS Configuration 31-29

    Default Ingress Queue Configuration 31-29Default Egress Queue Configuration 31-30Default Mapping Table Configuration 31-31

    Standard QoS Configuration Guidelines 31-31QoS ACL Guidelines 31-31Policing Guidelines 31-31General QoS Guidelines 31-32

    Enabling QoS Globally 31-32Configuring Classification Using Port Trust States 31-33

    Configuring the Trust State on Ports within the QoS Domain 31-33Configuring the CoS Value for an Interface 31-35Configuring a Trusted Boundary to Ensure Port Security 31-35Enabling DSCP Transparency Mode 31-37Configuring the DSCP Trust State on a Port Bordering Another QoS Domain 31-37

    Configuring a QoS Policy 31-39Classifying Traffic by Using ACLs 31-40Classifying Traffic by Using Class Maps 31-43Classifying, Policing, and Marking Traffic on Physical Ports by Using Policy Maps 31-45Classifying, Policing, and Marking Traffic by Using Aggregate Policers 31-48

    Configuring DSCP Maps 31-50Configuring the CoS-to-DSCP Map 31-51Configuring the IP-Precedence-to-DSCP Map 31-52Configuring the Policed-DSCP Map 31-53Configuring the DSCP-to-CoS Map 31-54Configuring the DSCP-to-DSCP-Mutation Map 31-55

    Configuring Ingress Queue Characteristics 31-56Mapping DSCP or CoS Values to an Ingress Queue and Setting WTD Thresholds 31-57Allocating Buffer Space Between the Ingress Queues 31-58Allocating Bandwidth Between the Ingress Queues 31-59Configuring the Ingress Priority Queue 31-60

    Configuring Egress Queue Characteristics 31-61

    xxiiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuration Guidelines 31-61Allocating Buffer Space to and Setting WTD Thresholds for an Egress Queue-Set 31-61Mapping DSCP or CoS Values to an Egress Queue and to a Threshold ID 31-64Configuring SRR Shaped Weights on Egress Queues 31-65Configuring SRR Shared Weights on Egress Queues 31-66Configuring the Egress Expedite Queue 31-67Limiting the Bandwidth on an Egress Interface 31-67

    Displaying Standard QoS Information 31-68

    C H A P T E R 32 Configuring IPv6 Host Functions 32-1

    Understanding IPv6 32-1IPv6 Addresses 32-2Supported IPv6 Unicast Routing Features 32-3

    128-Bit Wide Unicast Addresses 32-3DNS for IPv6 32-4ICMPv6 32-4Neighbor Discovery 32-4IPv6 Stateless Autoconfiguration and Duplicate Address Detection 32-4IPv6 Applications 32-9Dual IPv4 and IPv6 Protocol Stacks 32-10SNMP and Syslog Over IPv6 32-10HTTP(S) Over IPv6 32-11

    SDM Templates 32-12Dual IPv4-and-IPv6 SDM Templates 32-12

    Configuring IPv6 32-13Default IPv6 Configuration 32-13Configuring IPv6 ICMP Rate Limiting 32-14Configuring Static Routes for IPv6 32-14

    Displaying IPv6 32-17

    C H A P T E R 33 Configuring IPv6 MLD Snooping 33-1

    Understanding MLD Snooping 33-1MLD Messages 33-2MLD Queries 33-3Multicast Client Aging Robustness 33-3Multicast Router Discovery 33-3MLD Reports 33-4MLD Done Messages and Immediate-Leave 33-4Topology Change Notification Processing 33-5

    xxivCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Configuring IPv6 MLD Snooping 33-5Default MLD Snooping Configuration 33-5MLD Snooping Configuration Guidelines 33-6Enabling or Disabling MLD Snooping 33-6Configuring a Static Multicast Group 33-8Configuring a Multicast Router Port 33-8Enabling MLD Immediate Leave 33-9Configuring MLD Snooping Queries 33-10Disabling MLD Listener Message Suppression 33-11

    Displaying MLD Snooping Information 33-11

    C H A P T E R 34 Configuring EtherChannels and Link-State Tracking 34-1

    Understanding EtherChannels 34-1EtherChannel Overview 34-2Port-Channel Interfaces 34-3Port Aggregation Protocol 34-4

    PAgP Modes 34-4PAgP Interaction with Other Features 34-5

    Link Aggregation Control Protocol 34-5LACP Modes 34-5LACP Interaction with Other Features 34-6

    EtherChannel On Mode 34-6Load Balancing and Forwarding Methods 34-6

    Configuring EtherChannels 34-8Default EtherChannel Configuration 34-9EtherChannel Configuration Guidelines 34-9Configuring Layer 2 EtherChannels 34-10Configuring EtherChannel Load Balancing 34-12Configuring the PAgP Learn Method and Priority 34-13Configuring LACP Hot-Standby Ports 34-14

    Configuring the LACP System Priority 34-15Configuring the LACP Port Priority 34-15

    Displaying EtherChannel, PAgP, and LACP Status 34-16

    Understanding Link-State Tracking 34-17

    Configuring Link-State Tracking 34-19Default Link-State Tracking Configuration 34-20Link-State Tracking Configuration Guidelines 34-20Configuring Link-State Tracking 34-20Displaying Link-State Tracking Status 34-21

    xxvCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    C H A P T E R 35 Troubleshooting 35-1

    Recovering from a Software Failure 35-2

    Recovering from a Lost or Forgotten Password 35-3Procedure with Password Recovery Enabled 35-4Procedure with Password Recovery Disabled 35-6

    Recovering from a Command Switch Failure 35-7Replacing a Failed Command Switch with a Cluster Member 35-8Replacing a Failed Command Switch with Another Switch 35-9

    Recovering from Lost Cluster Member Connectivity 35-11

    Preventing Autonegotiation Mismatches 35-11

    SFP Module Security and Identification 35-11

    Monitoring SFP Module Status 35-12

    Using Ping 35-12Understanding Ping 35-12Executing Ping 35-13

    Using Layer 2 Traceroute 35-13Understanding Layer 2 Traceroute 35-14Usage Guidelines 35-14Displaying the Physical Path 35-15

    Using IP Traceroute 35-15Understanding IP Traceroute 35-15Executing IP Traceroute 35-16

    Using TDR 35-17Understanding TDR 35-17Running TDR and Displaying the Results 35-17

    Using Debug Commands 35-18Enabling Debugging on a Specific Feature 35-18Enabling All-System Diagnostics 35-19Redirecting Debug and Error Message Output 35-19

    Using the show platform forward Command 35-19

    Using the crashinfo Files 35-21Basic crashinfo Files 35-21Extended crashinfo Files 35-21

    A P P E N D I X A Supported MIBs A-1

    MIB List A-1

    Using FTP to Access the MIB Files A-3

    xxviCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    A P P E N D I X B Working with the Cisco IOS File System, Configuration Files, and Software Images B-1

    Working with the Flash File System B-1Displaying Available File Systems B-2Setting the Default File System B-2Displaying Information about Files on a File System B-3Changing Directories and Displaying the Working Directory B-3Creating and Removing Directories B-4Copying Files B-4Deleting Files B-5Creating, Displaying, and Extracting tar Files B-5

    Creating a tar File B-6Displaying the Contents of a tar File B-6Extracting a tar File B-7

    Displaying the Contents of a File B-7

    Working with Configuration Files B-8Guidelines for Creating and Using Configuration Files B-9Configuration File Types and Location n B-9Creating a Configuration File By Using a Text Editor B-9Copying Configuration Files By Using TFTP B-10

    Preparing to Download or Upload a Configuration File B y Using TFTP B-10Downloading the Configuration File By Using TFTP B-11Uploading the Configuration File By Using TFTP B-11

    Copying Configuration Files By Using FTP B-12Preparing to Download or Upload a Configuration File By Using FTP B-12Downloading a Configuration File By Using FTP B-13Uploading a Configuration File By Using FTP B-14

    Copying Configuration Files By Using RCP B-15Preparing to Download or Upload a Configuration File By Using RCP B-15Downloading a Configuration File By Using RCP B-16Uploading a Configuration File By Using RCP B-17

    Clearing Configuration Information B-18Clearing the Startup Configuration File B-18Deleting a Stored Configuration File B-18

    Replacing and Rolling Back Configurations B-18Understanding Configuration Replacement and Rollback B-19Configuration Guidelines B-20Configuring the Configuration Archive B-20Performing a Configuration Replacement or Rollback Operation B-21

    Working with Software Images B-22

    xxviiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Image Location on the Switch B-23tar File Format of Images on a Server or Cisco.com B-23Copying Image Files By Using TFTP B-24

    Preparing to Download or Upload an Image File By Using TFTP B-25Downloading an Image File By Using TFTP B-25Uploading an Image File By Using TFTP B-27

    Copying Image Files By Using FTP B-27Preparing to Download or Upload an Image File By Using FTP B-28Downloading an Image File By Using FTP B-29Uploading an Image File By Using FTP B-30

    Copying Image Files By Using RCP B-31Preparing to Download or Upload an Image File By Using RCP B-32Downloading an Image File By Using RCP B-33Uploading an Image File By Using RCP B-35

    A P P E N D I X C Recommendations for Upgrading a Catalyst 2950 Switch to a Catalyst 2960 Switch C-1

    Configuration Compatibility Issues C-1

    Feature Behavior Incompatibilities C-5

    A P P E N D I X D Unsupported Commands in Cisco IOS Release 12.2(44)SE D-1

    Access Control Lists D-1Unsupported Privileged EXEC Commands D-1Unsupported Global Configuration Commands D-1Unsupported Route-Map Configuration Commands D-1

    Boot Loader Commands D-2Unsupported Global Configuration Commands D-2

    Debug Commands D-2Unsupported Privileged EXEC Commands D-2

    |IGMP Snooping Commands D-2Unsupported Global Configuration Commands D-2

    Interface Commands D-2Unsupported Privileged EXEC Commands D-2Unsupported Global Configuration Commands D-2Unsupported Interface Configuration Commands D-2

    MAC Address Commands D-3Unsupported Privileged EXEC Commands D-3Unsupported Global Configuration Commands D-3

    Miscellaneous D-3

    xxviiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    Unsupported Privileged EXEC Commands D-3Unsupported Global Configuration Commands D-4

    Network Address Translation (NAT) Commands D-4Unsupported Privileged EXEC Commands D-4

    QoS D-4Unsupported Global Configuration Command D-4Unsupported Interface Configuration Commands D-4Unsupported Policy-Map Configuration Command D-4

    RADIUS D-4Unsupported Global Configuration Commands D-4

    SNMP D-5Unsupported Global Configuration Commands D-5

    Spanning Tree D-5Unsupported Global Configuration Command D-5Unsupported Interface Configuration Command D-5

    VLAN D-5Unsupported Global Configuration Command D-5Unsupported vlan-config Command D-5Unsupported User EXEC Commands D-5

    VTP D-6Unsupported Privileged EXEC Commands D-6

    IN D E X

    xxixCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Contents

    xxxCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Preface

    AudienceThis guide is for the networking professional managing the Catalyst 2960 switch, hereafter referred to as the switch module. Before using this guide, you should have experience working with the Cisco IOS software and be familiar with the concepts and terminology of Ethernet and local area networking.

    PurposeThis guide provides the information that you need to configure Cisco IOS software features on your switch. The Catalyst 2960 software provides enterprise-class intelligent services such as access control lists (ACLs) and quality of service (QoS) features. The Catalyst 2960 switch is supported by either the LAN Base or the LAN Lite image.

    This guide provides procedures for using the commands that have been created or changed for use with the Catalyst 2960 switch. It does not provide detailed information about these commands. For detailed information about these commands, see the 2960 Switch Command Reference for this release. For information about the standard Cisco IOS Release 12.2 commands, see the Cisco IOS documentation set available from the Cisco.com home page at Documentation > Cisco IOS Software.

    This guide does not provide detailed information on the graphical user interfaces (GUIs) for the embedded device manager or for Cisco Network Assistant (hereafter referred to as Network Assistant) that you can use to manage the switch. However, the concepts in this guide are applicable to the GUI user. For information about the device manager, see the switch online help. For information about Network Assistant, see Getting Started with Cisco Network Assistant, available on Cisco.com.

    This guide does not describe system messages you might encounter or how to install your switch. For more information, see the Catalyst 2960 Switch System Message Guide for this release and the Catalyst 2960 Switch Hardware Installation Guide.

    For documentation updates, see the release notes for this release.

    xxxiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • PrefaceConventions

    ConventionsThis publication uses these conventions to convey instructions and information:

    Command descriptions use these conventions:

    Commands and keywords are in boldface text.

    Arguments for which you supply values are in italic.

    Square brackets ([ ]) mean optional elements.

    Braces ({ }) group required choices, and vertical bars ( | ) separate the alternative elements.

    Braces and vertical bars within square brackets ([{ | }]) mean a required choice within an optional element.

    Interactive examples use these conventions:

    Terminal sessions and system displays are in screen font.

    Information you enter is in boldface screen font.

    Nonprinting characters, such as passwords or tabs, are in angle brackets (< >).

    Notes, cautions, and timesavers use these conventions and symbols:

    Note Means reader take note. Notes contain helpful suggestions or references to materials not contained in this manual.

    Caution Means reader be careful. In this situation, you might do something that could result in equipment damage or loss of data.

    Related PublicationsThese documents provide complete information about the switch and are available from this Cisco.com site:

    http://www.cisco.com/en/US/products/ps6406/tsd_products_support_series_home.html

    Note Before installing, configuring, or upgrading the switch, see these documents:

    For initial configuration information, see the Using Express Setup section in the getting started guide or the Configuring the Switch with the CLI-Based Setup Program appendix in the hardware installation guide.

    For device manager requirements, see the System Requirements section in the release notes (not orderable but available on Cisco.com).

    For Network Assistant requirements, see the Getting Started with Cisco Network Assistant (not orderable but available on Cisco.com).

    xxxiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

    http://www.cisco.com/en/US/products/ps6406/tsd_products_support_series_home.html

  • PrefaceRelated Publications

    For cluster requirements, see the Release Notes for Cisco Network Assistant (not orderable but available on Cisco.com).

    For upgrading information, see the Downloading Software section in the release notes.

    You can order printed copies of documents with a DOC-xxxxxx= number from the Cisco.com sites and from the telephone numbers listed in the URL referenced in the Obtaining Documentation, Obtaining Support, and Security Guidelines section on page xxxiv.

    Release Notes for the Catalyst 3750, 3560, 2970, and 2960 Switches (not orderable but available on Cisco.com)

    Catalyst 3750, 3560, 3550, 2970, and 2960 Switch System Message Guide (not orderable but available on Cisco.com)

    Catalyst 2960 Switch Software Configuration Guide (not orderable but available on Cisco.com)

    Catalyst 2960 Switch Command Reference (not orderable but available on Cisco.com)

    Device manager online help (available on the switch)

    Catalyst 2960 Switch Hardware Installation Guide (not orderable but available on Cisco.com)

    Catalyst 2960 Switch Getting Started Guide (order number DOC-7816879=)

    Regulatory Compliance and Safety Information for the Catalyst 2960 Switch (order number DOC-7816880=)

    Getting Started with Cisco Network Assistant (not orderable but available on Cisco.com)

    Release Notes for Cisco Network Assistant (not orderable but available on Cisco.com)

    Cisco Small Form-Factor Pluggable Modules Installation Notes (order number DOC-7815160=)

    Cisco RPS 300 Redundant Power System Hardware Installation Guide (order number DOC-7810372=)

    Cisco RPS 675 Redundant Power System Hardware Installation Guide (order number DOC-7815201=)

    Cisco Redundant Power System 2300 Hardware Installation Guide (order number DOC-7817647=)

    For more information about the Network Admission Control (NAC) features, see the Network Admission Control Software Configuration Guide (not orderable but available on Cisco.com)

    These compatibility matrix documents are available from this Cisco.com site:

    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html

    Cisco Gigabit Ethernet Transceiver Modules Compatibility Matrix (not orderable but available on Cisco.com)

    Cisco 100-Megabit Ethernet SFP Modules Compatibility Matrix (not orderable but available on Cisco.com)

    Cisco Small Form-Factor Pluggable Modules Compatibility Matrix (not orderable but available on Cisco.com)

    Compatibility Matrix for 1000BASE-T Small Form-Factor Pluggable Modules (not orderable but available on Cisco.com)

    xxxiiiCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

    http://www.cisco.com/en/US/products/hw/modules/ps5455/products_device_support_tables_list.html

  • PrefaceObtaining Documentation, Obtaining Support, and Security Guidelines

    Obtaining Documentation, Obtaining Support, and Security Guidelines

    For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly Whats New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at:

    http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

    Subscribe to the Whats New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free service and Cisco currently supports RSS version 2.0.

    xxxivCatalyst 2960 Switch Software Configuration Guide

    OL-8603-05

    http://www.cisco.com/en/US/docs/general/whatsnew/whatsnew.html

  • OL-8603-05

    C H A P T E R 1

    Overview

    This chapter provides these topics about the Catalyst 2960 switch software:

    Features, page 1-1

    Default Settings After Initial Switch Configuration, page 1-12

    Network Configuration Examples, page 1-14

    Where to Go Next, page 1-20

    Note In this document, IP refers to IP Version 4 (IPv4).

    FeaturesSome features described in this chapter are available only on the cryptographic (supports encryption) version of the software. You must obtain authorization to use this feature and to download the cryptographic version of the software from Cisco.com. For more information, see the release notes for this release.

    The switch has these features:

    Ease-of-Deployment and Ease-of-Use Features, page 1-2

    Performance Features, page 1-3

    Management Options, page 1-4

    Manageability Features, page 1-5 (includes a feature requiring the cryptographic version of the software)

    Availability and Redundancy Features, page 1-6

    VLAN Features, page 1-7

    Security Features, page 1-8 (includes a feature requiring the cryptographic version of the software)

    QoS and CoS Features, page 1-10

    Monitoring Features, page 1-11

    1-1Catalyst 2960 Switch Software Configuration Guide

  • Chapter 1 OverviewFeatures

    Ease-of-Deployment and Ease-of-Use FeaturesThe switch ships with these features to make the deployment and the use easier:

    Express Setup for quickly configuring a switch for the first time with basic IP information, contact information, switch and Telnet passwords, and Simple Network Management Protocol (SNMP) information through a browser-based program. For more information about Express Setup, see the getting started guide.

    User-defined and Cisco-default Smartports macros for creating custom switch configurations for simplified deployment across the network.

    An embedded device manager GUI for configuring and monitoring a single switch through a web browser. For information about launching the device manager, see the getting started guide. For more information about the device manager, see the switch online help.

    Cisco Network Assistant (hereafter referred to as Network Assistant) for

    Note The Network Assistant must be downloaded from cisco.com/go/cna.

    Managing communities, which are device groups like clusters, except that they can contain routers and access points and can be made more secure.

    Simplifying and minimizing switch and switch cluster management from anywhere in your intranet.

    Accomplishing multiple configuration tasks from a single graphical interface without needing to remember command-line interface (CLI) commands to accomplish specific tasks.

    Interactive guide mode that guides you in configuring complex features such as VLANs, ACLs, and quality of service (QoS).

    Note If the switch is running the LAN Lite image, you can configure ACLs, but you cannot attach them to interfaces or VLANs.

    Configuration wizards that prompt you to provide only the minimum required information to configure complex features such as QoS priorities for traffic, priority levels for data applications, and security.

    Downloading an image to a switch.

    Applying actions to multiple ports and multiple switches at the same time, such as VLAN and QoS settings, inventory and statistic reports, link- and switch-level monitoring and troubleshooting, and multiple switch software upgrades.

    Viewing a topology of interconnected devices to identify existing switch clusters and eligible switches that can join a cluster and to identify link information between switches.

    Monitoring real-time status of a switch or multiple switches from the LEDs on the front-panel images. The system, redundant power system (RPS), and port LED colors on the images are similar to those used on the physical LEDs.

    Note To use RPS, the switch must be running the LAN Base image.

    1-2Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

    cisco.com/go/cna

  • Chapter 1 OverviewFeatures

    Switch clustering technology for

    Unified configuration, monitoring, authentication, and software upgrade of multiple, cluster-capable switches, regardless of their geographic proximity and interconnection media, including Ethernet, Fast Ethernet, Fast EtherChannel, small form-factor pluggable (SFP) modules, Gigabit Ethernet, and Gigabit EtherChannel connections. For a list of cluster-capable switches, see the release notes.

    Automatic discovery of candidate switches and creation of clusters of up to 16 switches that can be managed through a single IP address.

    Extended discovery of cluster candidates that are not directly connected to the command switch.

    Performance FeaturesThe switch ships with these performance features:

    Autosensing of port speed and autonegotiation of duplex mode on all switch ports for optimizing bandwidth

    Automatic-medium-dependent interface crossover (auto-MDIX) capability on 10/100 and 10/100/1000 Mb/s interfaces and on 10/100/1000 BASE-TX SFP module interfaces that enables the interface to automatically detect the required cable connection type (straight-through or crossover) and to configure the connection appropriately

    Support for up to 9000 bytes for frames that are bridged in hardware, and up to 2000 bytes for frames that are bridged by software

    IEEE 802.3x flow control on all ports (the switch does not send pause frames)

    EtherChannel for enhanced fault tolerance and for providing up to 8 Gb/s (Gigabit EtherChannel) or 800 Mb/s (Fast EtherChannel) full-duplex bandwidth among switches, routers, and servers

    Port Aggregation Protocol (PAgP) and Link Aggregation Control Protocol (LACP) for automatic creation of EtherChannel links

    Forwarding of Layer 2 packets at Gigabit line rate

    Per-port storm control for preventing broadcast, multicast, and unicast storms

    Port blocking on forwarding unknown Layer 2 unknown unicast, multicast, and bridged broadcast traffic

    Internet Group Management Protocol (IGMP) snooping for IGMP Versions 1, 2, and 3 for efficiently forwarding multimedia and multicast traffic

    IGMP report suppression for sending only one IGMP report per multicast router query to the multicast devices (supported only for IGMPv1 or IGMPv2 queries)

    IGMP snooping querier support to configure switch to generate periodic IGMP general query messages

    IPv6 host support for basic IPv6 management

    Note To use IPv6, the switch must be running the LAN Base image.

    Multicast Listener Discovery (MLD) snooping to enable efficient distribution of IP version 6 (IPv6) multicast data to clients and routers in a switched network

    Multicast VLAN registration (MVR) to continuously send multicast streams in a multicast VLAN while isolating the streams from subscriber VLANs for bandwidth and security reasons

    1-3Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    Note To use MVR, the switch must be running the LAN Base image.

    IGMP filtering for controlling the set of multicast groups to which hosts on a switch port can belong

    IGMP throttling for configuring the action when the maximum number of entries is in the IGMP forwarding table

    IGMP leave timer for configuring the leave latency for the network

    Switch Database Management (SDM) templates for allocating system resources to maximize support for user-selected features

    Support for Cisco IOS IP Service Level Agreements (SLAs) responder that allows the system to anticipate and respond to Cisco IOS IP SLAs request packets for monitoring network performance. See the release notes for responder configuration

    Configurable small-frame arrival threshold to prevent storm control when small frames (64 bytes or less) arrive on an interface at a specified rate (the threshold)

    Flex Link Multicast Fast Convergence to reduce the multicast traffic convergence time after a Flex Link failure

    Note To use Flex Link Multicast Fast Convergence, the switch must be running the LAN Base image.

    Management OptionsThese are the options for configuring and managing the switch:

    An embedded device managerThe device manager is a GUI that is integrated in the software image. You use it to configure and to monitor a single switch. For information about launching the device manager, see the getting started guide. For more information about the device manager, see the switch online help.

    Network AssistantNetwork Assistant is a network management application that can be downloaded from Cisco.com. You use it to manage a single switch, a cluster of switches, or a community of devices. For more information about Network Assistant, see Getting Started with Cisco Network Assistant, available on Cisco.com.

    CLIThe Cisco IOS software supports desktop- and multilayer-switching features. You can access the CLI either by connecting your management station directly to the switch console port or by using Telnet from a remote management station. For more information about the CLI, see Chapter 2, Using the Command-Line Interface.

    SNMPSNMP management applications such as CiscoWorks2000 LAN Management Suite (LMS) and HP OpenView. You can manage from an SNMP-compatible management station that is running platforms such as HP OpenView or SunNet Manager. The switch supports a comprehensive set of MIB extensions and four remote monitoring (RMON) groups. For more information about using SNMP, see Chapter 28, Configuring SNMP.

    CNSCisco Networking Services is network management software that acts as a configuration service for automating the deployment and management of network devices and services. You can automate initial configurations and configuration updates by generating switch-specific configuration changes, sending them to the switch, executing the configuration change, and logging the results.

    For more information about CNS, see Chapter 4, Configuring Cisco IOS CNS Agents.

    1-4Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    Manageability FeaturesThese are the manageability features:

    CNS embedded agents for automating switch management, configuration storage, and delivery

    DHCP for automating configuration of switch information (such as IP address, default gateway, hostname, and Domain Name System [DNS] and TFTP server names)

    DHCP relay for forwarding User Datagram Protocol (UDP) broadcasts, including IP address requests, from DHCP clients

    DHCP server for automatic assignment of IP addresses and other DHCP options to IP hosts

    DHCP-based autoconfiguration and image update to download a specified configuration a new image to a large number of switches

    Directed unicast requests to a DNS server for identifying a switch through its IP address and its corresponding hostname and to a TFTP server for administering software upgrades from a TFTP server

    Address Resolution Protocol (ARP) for identifying a switch through its IP address and its corresponding MAC address

    Unicast MAC address filtering to drop packets with specific source or destination MAC addresses

    Cisco Discovery Protocol (CDP) Versions 1 and 2 for network topology discovery and mapping between the switch and other Cisco devices on the network

    Link Layer Discovery Protocol (LLDP) and LLDP Media Endpoint Discovery (LLDP-MED) for interoperability with third-party IP phones

    Note To use LLDP-MED, the switch must be running the LAN Base image.

    LLDP media extensions (LLDP-MED) location TLV that provides location information from the switch to the endpoint device

    Network Time Protocol (NTP) for providing a consistent time stamp to all switches from an external source

    Cisco IOS File System (IFS) for providing a single interface to all file systems that the switch uses

    Support for the SSM PIM protocol to optimize multicast applications, such as video

    Source Specific Multicast (SSM) mapping for multicast applications provides a mapping of source to group, allowing listeners to connect to multicast sources dynamically and reduces dependencies on the application

    Support for Enhanced Interior Gateway Routing Protocol (EIGRP) IPv6 to utilize IPv6 transport, communicate with IPv6 peers, and advertise IPv6 routes

    Support for these IP services, making them VRF aware so that they can operate on multiple routing instances: HSRP, GLBP, uRPF, ARP, SNMP, IP SLA, TFTP, FTP, syslog, traceroute, and ping

    Configuration logging to log and to view changes to the switch configuration

    Unique device identifier to provide product identification information through a show inventory user EXEC command display

    In-band management access through the device manager over a Netscape Navigator or Microsoft Internet Explorer browser session

    1-5Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    In-band management access for up to 16 simultaneous Telnet connections for multiple CLI-based sessions over the network

    In-band management access for up to five simultaneous, encrypted Secure Shell (SSH) connections for multiple CLI-based sessions over the network (requires the cryptographic version of the software)

    In-band management access through SNMP Versions 1, 2c, and 3 get and set requests

    Out-of-band management access through the switch console port to a directly attached terminal or to a remote terminal through a serial connection or a modem

    Secure Copy Protocol (SCP) feature to provide a secure and authenticated method for copying switch configuration or switch image files (requires the cryptographic version of the software)

    Configuration replacement and rollback to replace the running configuration on a switch with any saved Cisco IOS configuration file

    The HTTP client in Cisco IOS supports can send requests to both IPv4 and IPv6 HTTP server, and the HTTP server in Cisco IOS can service HTTP requests from both IPv4 and IPv6 HTTP clients

    Simple Network and Management Protocol (SNMP) can be configured over IPv6 transport so that an IPv6 host can send SNMP queries and receive SNMP notifications from a device running IPv6

    IPv6 stateless autoconfiguration to manage link, subnet, and site addressing changes, such as management of host and mobile IP addresses

    Availability and Redundancy FeaturesThese are the availability and redundancy features:

    Enhanced object tracking, which separates the tracking mechanism from HSRP and creates a separate, standalone tracking process that can be used by processes other than HSRP

    UniDirectional Link Detection (UDLD) and aggressive UDLD for detecting and disabling unidirectional links on fiber-optic interfaces caused by incorrect fiber-optic wiring or port faults

    IEEE 802.1D Spanning Tree Protocol (STP) for redundant backbone connections and loop-free networks. STP has these features:

    Up to 128 spanning-tree instances supported

    Note Up to 64 spanning-tree instances are supported when the switch is running the LAN Lite image.

    Per-VLAN spanning-tree plus (PVST+) for load balancing across VLANs

    Rapid PVST+ for load balancing across VLANs and providing rapid convergence of spanning-tree instances

    UplinkFast and BackboneFast for fast convergence after a spanning-tree topology change and for achieving load balancing between redundant uplinks, including Gigabit uplinks

    IEEE 802.1s Multiple Spanning Tree Protocol (MSTP) for grouping VLANs into a spanning-tree instance and for providing multiple forwarding paths for data traffic and load balancing and rapid per-VLAN Spanning-Tree plus (rapid-PVST+) based on the IEEE 802.1w Rapid Spanning Tree Protocol (RSTP) for rapid convergence of the spanning tree by immediately changing root and designated ports to the forwarding state

    1-6Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    Optional spanning-tree features available in PVST+, rapid-PVST+, and MSTP mode:

    Port Fast for eliminating the forwarding delay by enabling a port to immediately change from the blocking state to the forwarding state

    BPDU guard for shutting down Port Fast-enabled ports that receive bridge protocol data units (BPDUs)

    BPDU filtering for preventing a Port Fast-enabled port from sending or receiving BPDUs

    Root guard for preventing switches outside the network core from becoming the spanning-tree root

    Loop guard for preventing alternate or root ports from becoming designated ports because of a failure that leads to a unidirectional link

    Flex Link Layer 2 interfaces to back up one another as an alternative to STP for basic link redundancy

    Note To use Flex Links, the switch must be running the LAN Base image.

    Link-state tracking to mirror the state of the ports that carry upstream traffic from connected hosts and servers, and to allow the failover of the server traffic to an operational link on another Cisco Ethernet switch.

    Note To use Link-state Tracking, the switch must be running the LAN Base image.

    RPS support through the Cisco RPS 300 and Cisco RPS 675 for enhancing power reliability

    VLAN FeaturesThese are the VLAN features:

    Support for up to 255 VLANs for assigning users to VLANs associated with appropriate network resources, traffic patterns, and bandwidth

    Note Up to 64 VLANs are supported when the switch is running the LAN Lite image.

    Support for VLAN IDs in the 1 to 4094 range as allowed by the IEEE 802.1Q standard

    VLAN Query Protocol (VQP) for dynamic VLAN membership

    IEEE 802.1Q trunking encapsulation on all ports for network moves, adds, and changes; management and control of broadcast and multicast traffic; and network security by establishing VLAN groups for high-security users and network resources

    Dynamic Trunking Protocol (DTP) for negotiating trunking on a link between two devices and for negotiating the type of trunking encapsulation (IEEE 802.1Q) to be used

    VLAN Trunking Protocol (VTP) and VTP pruning for reducing network traffic by restricting flooded traffic to links destined for stations receiving the traffic

    Voice VLAN for creating subnets for voice traffic from Cisco IP Phones

    1-7Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    VLAN 1 minimization for reducing the risk of spanning-tree loops or storms by allowing VLAN 1 to be disabled on any individual VLAN trunk link. With this feature enabled, no user traffic is sent or received on the trunk. The switch CPU continues to send and receive control protocol frames.

    VLAN Flex Link Load Balancing to provide Layer 2 redundancy without requiring Spanning Tree Protocol (STP). A pair of interfaces configured as primary and backup links can load balance traffic based on VLAN.

    Note To use VLAN Flex Link Load Balancing, the switch must be running the LAN Base image.

    Security FeaturesThe switch ships with these security features:

    IP Service Level Agreements (IP SLAs) responder support that allows the switch to be a target device for IP SLAs active traffic monitoring

    Note To use IP SLAs, the switch must be running the LAN Base image.

    Web authentication to allow a supplicant (client) that does not support IEEE 802.1x functionality to be authenticated using a web browser

    Note To use Web Authentication, the switch must be running the LAN Base image.

    Password-protected access (read-only and read-write access) to management interfaces (device manager, Network Assistant, and the CLI) for protection against unauthorized configuration changes

    Multilevel security for a choice of security level, notification, and resulting actions

    Static MAC addressing for ensuring security

    Protected port option for restricting the forwarding of traffic to designated ports on the same switch

    Port security option for limiting and identifying MAC addresses of the stations allowed to access the port

    VLAN aware port security option to shut down the VLAN on the port when a violation occurs, instead of shutting down the entire port.

    Port security aging to set the aging time for secure addresses on a port

    BPDU guard for shutting down a Port Fast-configured port when an invalid configuration occurs

    Standard and extended IP access control lists (ACLs) for defining inbound security policies on Layer 2 interfaces (port ACLs)

    Extended MAC access control lists for defining security policies in the inbound direction on Layer 2 interfaces

    Source and destination MAC-based ACLs for filtering non-IP traffic

    DHCP snooping to filter untrusted DHCP messages between untrusted hosts and DHCP servers

    1-8Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    IEEE 802.1x port-based authentication to prevent unauthorized devices (clients) from gaining access to the network. These features are supported:

    Dynamic voice virtual LAN (VLAN) for MDA to allow a dynamic voice VLAN on an MDA-enabled port

    VLAN assignment for restricting IEEE 802.1x-authenticated users to a specified VLAN

    Port security for controlling access to IEEE 802.1x ports

    Voice VLAN to permit a Cisco IP Phone to access the voice VLAN regardless of the authorized or unauthorized state of the port

    IP phone detection enhancement to detect and recognize a Cisco IP phone.

    Guest VLAN to provide limited services to non-IEEE 802.1x-compliant users

    Restricted VLAN to provide limited services to users who are IEEE 802.1x compliant, but do not have the credentials to authenticate via the standard IEEE 802.1x processes

    Note To use authentication with restricted VLANs, the switch must be running the LAN Base image.

    IEEE 802.1x accounting to track network usage

    IEEE 802.1x with wake-on-LAN to allow dormant PCs to be powered on based on the receipt of a specific Ethernet frame

    Note To use authentication with wake-on-LAN, the switch must be running the LAN Base image.

    IEEE 802.1x readiness check to determine the readiness of connected end hosts before configuring IEEE 802.1x on the switch

    Note To use IEEE 802.1x readiness check, the switch must be running the LAN Base image.

    MAC authentication bypass to authorize clients based on the client MAC address.

    Note To use MAC authentication bypass, the switch must be running the LAN Base image.

    Network Admission Control (NAC) Layer 2 IEEE 802.1x validation of the antivirus condition or posture of endpoint systems or clients before granting the devices network access.

    For information about configuring NAC Layer 2 IEEE 802.1x validation, see the Configuring NAC Layer 2 IEEE 802.1x Validation section on page 9-40.

    Note To use NAC, the switch must be running the LAN Base image.

    TACACS+, a proprietary feature for managing network security through a TACACS server

    RADIUS for verifying the identity of, granting access to, and tracking the actions of remote users through authentication, authorization, and accounting (AAA) services

    1-9Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    Secure Socket Layer (SSL) Version 3.0 support for the HTTP 1.1 server authentication, encryption, and message integrity and HTTP client authentication to allow secure HTTP communications (requires the cryptographic version of the software)

    Voice aware IEEE 802.1x security to apply traffic violation actions only on the VLAN on which a security violation occurs

    QoS and CoS FeaturesThese are the QoS and CoS features:

    Automatic QoS (auto-QoS) to simplify the deployment of existing QoS features by classifying traffic and configuring egress queues

    Note To use auto-QoS, the switch must be running the LAN Base image.

    Classification

    IP type-of-service/Differentiated Services Code Point (IP ToS/DSCP) and IEEE 802.1p CoS marking priorities on a per-port basis for protecting the performance of mission-critical applications

    Note To use DSCP, the switch must be running the LAN Base image.

    IP ToS/DSCP and IEEE 802.1p CoS marking based on flow-based packet classification (classification based on information in the MAC, IP, and TCP/UDP headers) for high-performance quality of service at the network edge, allowing for differentiated service levels for different types of network traffic and for prioritizing mission-critical traffic in the network

    Note To use flow-based packet classification, the switch must be running the LAN Base image.

    Trusted port states (CoS, DSCP, and IP precedence) within a QoS domain and with a port bordering another QoS domain

    Trusted boundary for detecting the presence of a Cisco IP Phone, trusting the CoS value received, and ensuring port security

    Policing

    Note To use policy maps, the switch must be running the LAN Base image.

    Traffic-policing policies on the switch port for managing how much of the port bandwidth should be allocated to a specific traffic flow

    In Cisco IOS Release 12.2(25)SED and later, if you configure multiple class maps for a hierarchical policy map, each class map can be associated with its own port-level (second-level) policy map. Each second-level policy map can have a different policer.

    Aggregate policing for policing traffic flows in aggregate to restrict specific applications or traffic flows to metered, predefined rates

    1-10Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewFeatures

    Out-of-Profile

    Out-of-profile markdown for packets that exceed bandwidth utilization limits

    Ingress queueing and scheduling

    Two configurable ingress queues for user traffic (one queue can be the priority queue)

    Weighted tail drop (WTD) as the congestion-avoidance mechanism for managing the queue lengths and providing drop precedences for different traffic classifications

    Note To use WTD, the switch must be running the LAN Base image.

    Shaped round robin (SRR) as the scheduling service for specifying the rate at which packets are sent to the internal ring (sharing is the only supported mode on ingress queues)

    Note To use ingress queueing, the switch must be running the LAN Base image.

    Egress queues and scheduling

    Four egress queues per port

    WTD as the congestion-avoidance mechanism for managing the queue lengths and providing drop precedences for different traffic classifications

    SRR as the scheduling service for specifying the rate at which packets are dequeued to the egress interface (shaping or sharing is supported on egress queues). Shaped egress queues are guaranteed but limited to using a share of port bandwidth. Shared egress queues are also guaranteed a configured share of bandwidth, but can use more than the guarantee if other queues become empty and do not use their share of the bandwidth.

    Note To use egress queueing, the switch must be running the LAN Base image.

    Monitoring FeaturesThese are the monitoring features:

    Switch LEDs that provide port- and switch-level status

    MAC address notification traps and RADIUS accounting for tracking users on a network by storing the MAC addresses that the switch has learned or removed

    Switched Port Analyzer (SPAN) and Remote SPAN (RSPAN) for traffic monitoring on any port or VLAN

    SPAN and RSPAN support of Intrusion Detection Systems (IDS) to monitor, repel, and report network security violations

    Four groups (history, statistics, alarms, and events) of embedded RMON agents for network monitoring and traffic analysis

    Syslog facility for logging system messages about authentication or authorization errors, resource issues, and time-out events

    Layer 2 traceroute to identify the physical path that a packet takes from a source device to a destination device

    1-11Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewDefault Settings After Initial Switch Configuration

    Time Domain Reflector (TDR) to diagnose and resolve cabling problems on 10/100 and 10/100/1000 copper Ethernet ports

    SFP module diagnostic management interface to monitor physical or operational status of an SFP module

    Default Settings After Initial Switch ConfigurationThe switch is designed for plug-and-play operation, requiring only that you assign basic IP information to the switch and connect it to the other devices in your network. If you have specific network needs, you can change the interface-specific and system-wide settings.

    Note For information about assigning an IP address by using the browser-based Express Setup program, see the getting started guide. For information about assigning an IP address by using the CLI-based setup program, see the hardware installation guide.

    If you do not configure the switch at all, the switch operates with these default settings:

    Default switch IP address, subnet mask, and default gateway is 0.0.0.0. For more information, see Chapter 3, Assigning the Switch IP Address and Default Gateway, and Chapter 19, Configuring DHCP Features.

    Default domain name is not configured. For more information, see Chapter 3, Assigning the Switch IP Address and Default Gateway.

    DHCP client is enabled, the DHCP server is enabled (only if the device acting as a DHCP server is configured and is enabled), and the DHCP relay agent is enabled (only if the device is acting as a DHCP relay agent is configured and is enabled). For more information, see Chapter 3, Assigning the Switch IP Address and Default Gateway, and Chapter 19, Configuring DHCP Features.

    Switch cluster is disabled. For more information about switch clusters, see Chapter 5, Clustering Switches, and the Getting Started with Cisco Network Assistant, available on Cisco.com.

    No passwords are defined. For more information, see Chapter 6, Administering the Switch.

    System name and prompt is Switch. For more information, see Chapter 6, Administering the Switch.

    NTP is enabled. For more information, see Chapter 6, Administering the Switch.

    DNS is enabled. For more information, see Chapter 6, Administering the Switch.

    TACACS+ is disabled. For more information, see Chapter 8, Configuring Switch-Based Authentication.

    RADIUS is disabled. For more information, see Chapter 8, Configuring Switch-Based Authentication.

    The standard HTTP server and Secure Socket Layer (SSL) HTTPS server are both enabled. For more information, see Chapter 8, Configuring Switch-Based Authentication.

    IEEE 802.1x is disabled. For more information, see Chapter 9, Configuring IEEE 802.1x Port-Based Authentication.

    1-12Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewDefault Settings After Initial Switch Configuration

    Port parameters

    Interface speed and duplex mode is autonegotiate. For more information, see Chapter 10, Configuring Interface Characteristics.

    Auto-MDIX is enabled. For more information, see Chapter 10, Configuring Interface Characteristics.

    Flow control is off. For more information, see Chapter 10, Configuring Interface Characteristics.

    No Smartports macros are defined. For more information, see Chapter 11, Configuring Smartports Macros.

    VLANs

    Default VLAN is VLAN 1. For more information, see Chapter 12, Configuring VLANs.

    VLAN trunking setting is dynamic auto (DTP). For more information, see Chapter 12, Configuring VLANs.

    Trunk encapsulation is negotiate. For more information, see Chapter 12, Configuring VLANs.

    VTP mode is server. For more information, see Chapter 13, Configuring VTP.

    VTP version is Version 1. For more information, see Chapter 13, Configuring VTP.

    Voice VLAN is disabled. For more information, see Chapter 14, Configuring Voice VLAN.

    STP, PVST+ is enabled on VLAN 1. For more information, see Chapter 15, Configuring STP.

    MSTP is disabled. For more information, see Chapter 16, Configuring MSTP.

    Optional spanning-tree features are disabled. For more information, see Chapter 17, Configuring Optional Spanning-Tree Features.

    Flex Links are not configured. For more information, see Chapter 18, Configuring Flex Links and the MAC Address-Table Move Update Feature.

    Note To use Flex Links, the switch must be running the LAN Base image.

    DHCP snooping is disabled. The DHCP snooping information option is enabled. For more information, see Chapter 19, Configuring DHCP Features.

    IGMP snooping is enabled. No IGMP filters are applied. For more information, see Chapter 20, Configuring IGMP Snooping and MVR.

    IGMP throttling setting is deny. For more information, see Chapter 20, Configuring IGMP Snooping and MVR.

    The IGMP snooping querier feature is disabled. For more information, see Chapter 20, Configuring IGMP Snooping and MVR.

    MVR is disabled. For more information, see Chapter 20, Configuring IGMP Snooping and MVR.

    Note To use MVR, the switch must be running the LAN Base image.

    1-13Catalyst 2960 Switch Software Configuration Guide

    OL-8603-05

  • Chapter 1 OverviewNetwork Configuration Examples

    Port-based traffic

    Broadcast, multicast, and unicast storm control is disabled. For more information, see Chapter 21, Configuring Port-Based Traffic Control.

    No protected ports are defined. For more information, see Chapter 21, Configuring Port-Based Traffic Control.

    Unicast and multicast traffic flooding is not blocked. For more information, see Chapter 21, Configuring Port-Based Traffic Control.

    No secure ports are configured. For more information, see Chapter 21, Configuring Port-Based Traffic Control.

    CDP is enabled. For more information, see Chapter 22, Configuring CDP.

    UDLD is disabled. For more information, see Chapter 24, Configuring UDLD.

    SPAN and RSPAN are disabled. For more information, see Chapter 25, Configuring SPAN and RSPAN.

    Note To use RSPAN, the switch must be running the LAN Base image.

    RMON is disabled. For more information, see Chapter 26, Configuring RMON.

    Syslog messages are enabled and appear on the console. For more information, see Chapter 27, Configuring System Message Logging.

    SNMP is enabled (Version 1). For more information, see Chapter 28, Configuring SNMP.

    No ACLs are configured. For more information, see Chapte