Click here to load reader

CC-Link & CC-Link_LT Catalog

  • View
    826

  • Download
    16

Embed Size (px)

Text of CC-Link & CC-Link_LT Catalog

2007

Mar

S trategic Network, CC - Link & CC - Link/LT.S t r o n g S t a y M a n u f a c t u r e r s S t e p & A h e a d o f O t h e r s w i t h O n e C C - L i n k C C - L i n k / L T

INDEXConcept3 to 20

Compatible Products

System Configuration Example Product Information

22 23

25 to 134

System Configuration Example Product Information

136

137 to 140 141 to 188

Let's Start Powerful Factory Automation. Let's Connect with Powerful Networks.

Embedded Modules Other/Software Technical Information Support

190 191 to 198 199 to 214 215 to 224 225 to 228

Product List

231 to 234

Opening up the Future of FA Networks and Focusing on what'sWe provide total support in constructing seamless networks in all scenes, from offices to production sites, under a consistent design philosophy. With flexible approaches backed by "Ethernet," "MELSECNET/H" and "CC-Link", a SEMI-certified, world standard field network originated in Japan, and "CC-Link/LT", a sensor level network adhering to the design concept of CC-Link, we propose a network-based FA environment, fit for your needs.

Seamless integration of the network over all layersEthernet Enterprise level network

[Between factory departments] Enterprise level network

Ethernet

100/10 Mbps

The top layer of the Network hierarchy. It contributes to higher production efficiency through the collection and management of various production information around a plant.

MELSECNET/H Control level networkPOWER

EthernetQ25HCPUMODE RUN ERR USER BAT BOOT

QX42-S1

QX42-S1

QY42P QY42P

PULL

PULL

USB

RS-232

CC-Link Device level networkPULL POWER

Q25HCPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

QX42-S1

POWER

Q25HCPUMODE

QX42-S1

QJ71LP21-25

QY42P QY42P

QX42-S1

RUN ERR USER BAT BOOT

QY42P QY42P

PULL

PULL

PULL

USB

USB

[Within factory] Control level networkMax. 25 Mbps

MELSECNET/H

CC-Link/LTPULL

RS-232

RS-232

Q64P POWER

Q25HCPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

QJ71C24-R2 QJ61BT-11

PULL

Sensor level network

USB

MELSECNET/HPOWER

Q25HCPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

QX42-S1

POWER

Q25HCPUMODE RUN

QJ71LP21-25

POWER

Q25HCPUMODE RUN

Q12HCPUMODE RUN ERR USER BAT BOOT

QX42-S1

QX42-S1

QJ71LP21-25

QY42P QY42P

QX42-S1

QX42-S1

QY42P QY42P

QY42P QY42P

ERR USER BAT BOOT

ERR USER BAT BOOT

PULL

PULL

PULL

MELSECNET/H allows communication between controllers on a line. Its high-speed communication and large-capacity link device ensures real-time transmission of data relating directly to the operation and performance of machines and equipment among controllers.

PULL

PULL

PULLPULL

USB

USB

USB USB

RS-232

RS-232

RS-232 RS-232

[Within line] Device level networkCC-Link is a high-speed field network capable of controlling the system and handling information at the same time, and offers high-speed, reliable input/output response and highly flexible expandability. This distinguished performance the network earned SEMI certification. A Japaneseorigin, world standard open field network, CC-Link holds a large market share and has been winning the confidence of customers.SERVO SYSTEM CONTROLLER NETWORK

Max. 10 Mbps

Q64P POWER

Q25HCPUMODE RUN ERR USER BAT BOOT

QX42-S1

QX42-S1

QJ71C24-R2 QJ61CL12 QJ61BT-11

PULL

PULL

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8USB

ON

High-speed communication at a maximum baud rate of 10 Mbps Remote input/output (RX, RY): 8,192 points each Remote register (RWw) : 2,048 words (RWr) : 2,048 words(when CC-Link Ver. 2.0 is used)

Integration with 3rd party manufacture productsMax. 2.5 Mbps Max. 2.5 MbpsFX3UC-32MTLT

[Within panel and devices] Sensor level networkCL2X16-D1 M1V CL2X16-D1 M1V

Max. 2.5 MbpsLC 2X1 1DS3 D LC 2X1 1DCL2X16-D1 M1V

S3DCL1PAD1

CC-Link/LT is a sensor level network designed so that all production sites are free from complicated wiring or incorrect wiring. It inherits openness, high speed, and noise resistance from the CC-Link family and at the same time ensures reduced wiring because of its simple setting and easy installation.

CL1PAD1

CL2Y8-TP1B2

CL2Y8-TP1B2L 2X1 1DS 3D C

CL2Y8-TP1B2

Easy installation using dedicated connectors The adoption of point number modes (fou points, eight points, 16 points) permits effective use of I/O points. The maximum number of link points is 1,024 in 16-point mode.

Full-scale support system that helps customers make reliable, satisfied use of networks

We provide customers all over the world total support for FA networks, including CC-Link and CC-Link/LT, through our "Mitsubishi Global FA Center"s for overseas production support.

3

4

CC-Link - Proceeding toward a World Standard Network

Max. 10 Mbps

Q64P POWER

Q25HCPU QX42-S1MODE RUN ERR USER BAT BOOT

QX42-S1

QJ71C24-R2 QJ61CL12 QJ61BT-11

PULL

PULL

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8USB

ON

For improved setup efficiency [Simple parameter setup]You can set parameters on CC-Link using only the MELSEC total programming tool "GX Developer." You can significantly reduce program size and efficiently set parameters.

For achieving complex control, high-mix low-volume production [High-speed, high-capacity transmission]CC-Link is a high-performance network that utilizes high-speed communications (10 Mbps -top level in the industry-), in order to allow transmission of bit data and word data at high-speed and maximum capacity.

Max. 2.5 Mbps

Max. 2.5 Mbps

Max. 2.5 Mbps

FX3UC-32MT-L

T

CL2X16-D1M1

V

CL2X16-D1M1 V

CL2X16-D1M1

V

1 S3DCL1PAD1

X D-2

1LC

1DS 3DCL1PAD1

LC 2X1

1 S3D

X D-2

1LC

CL2Y8-TP1B2

CL2Y8-TP1B2

CL2Y8-TP1B2

For a simple and cost effective network [Reduced-wiring network]CC-link realizes simple and cost-effective network, and it is designed to relieve production lines from complicated wiring.

CC-LinkControl methods I/O control + intelligent distribution Dedicated fixed cable, dedicated flexible cable, built-in power cable RXRY: 8192 points each, RWr: 2048 words, RWw: 2048 words (Ver2.0) Screw terminal block, spring terminal block, e-CON, Push-in connector, waterproof connector, 40-pin connector 1200 m (at 156 kbps) Extendable up to 13.2 km when repeater is used

CC-Link/LTI/O controlONQ64P POWER

Q25HCPUMODE RUN

1 2 4 1 2 4 8 10 20 40 B RATE STATION NO.

PW L RUN L ERR. 0 1 2 3 4 5 6 7 8 9 A B C D E F

Q172CPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

QJ71C24-R2

QJ61CL12

Cable

Dedicated flat cable, VCTF (Vinyl Cabtire Code), dedicated flexible cable

ERR USER BAT BOOT

QJ61BT-11

PW

CC-Link L RUN L ERR.

CC-Link/LT L RUN L ERR. L ERR.1 2 3 4

CC-LinkSTATION 40 20 10 8 NO. 4 2 1 B RATE NOS TST MODE B 4 2 1 RATE NC 2 1 2 1 2 1 7 8 9 10

CC-Link/LT

AJ65VBTS3-16D

FRONT

PULL

SSCNET CH2

PULLPULL

CH1

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

ON

5

6

AJ65SBT-CLBCC-Link

ON

1 2 3 4 5 6 7 8NC X0 X1 X2 X3 X4 X5

X6

X7

X8

X9

XA

XB

USB USB

XC

CC-Link/LT

CON

A

COM1+ B C D COM1+

XD

XE

XF

RS-232

COM1COM1-

Maximum number of link points I/O Module Line-up

RXRY: 1024 points each

Screw terminal block, spring terminal block, e-CON, MIL connector, cable connector Trunk: 500 m Branch: 200 m (at 156 kbps)

Max. 10 Mbps

Max. cable distance

Parameter setup

GX Developer

Not required

Large-scale applications from Factory Automation through building management [Max. cable length of 13.2 km]Overall cable distance of CC-Link The total distance covered 100 by the CC-Link network can When repeater are not used 4,300 10 Mbps be increased up to 1.2km 1,100 When optical repeaters (GI cables) are used (at 156 kbps). Additionally, 160 4,480 5 Mbps When repeaters the transmission distance 1,760 (T-branch) are used can be further extended 400 5,200 2.5 Mbps through the use of T-branch 4,400 repeater modules. 900 6,700 Optical repeaters can also 625 kbps 9,900 be used so that CC-Link deal 1,200 7,600 156 kbps with various large-scale 13,200 facilities.0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 (m)

A diverse range of products from partner manufacturers [Multi-vendor system]More than 500 type of products are supplieds from more than 500 companies worldwide.

For improved network reliability [Consistent network communication time]CC-link guarantees the fixed cyclic transmission time and the cyclic transmission time is not affected by irregular message transmission. It is therefore possible to achieve highly stable control.Remote I/O station only Remote device station only (when all stations 1 station is occupied) Local node/intelligent device station only (when all stations 1 station is occupied)

Link scan time (ms)

Number of link points per station

RXRY: 32 points each, RWr: 4 words, RWw: 4 words RXRY: 128 points each, RWr: 32 words, RWw: 32 words Bus topology T-branch topology Star topology

CC-Link Link Scan Time (at communication speed of 10 Mbps)6 5 4 3 2 1 0 0 20 40 60 Number of units [units]

Max, 16 points (in 16-point mode)

For non-stop operation [RAS functions]CC-Link equips full RAS functionality by functions like Standby Master, Automatic Return, Slave Station Isolation and Diagnostics/Link Status Confirmation.* RAS: Reliability, Availability, Serviceability

Network topology

T-branch topology

5

6

CC-Link/LT - in pursuit of benefits through wire saving.

Max. 10 Mbps

Q64P POWER

Q25HCPU QX42-S1MODE RUN ERR USER BAT BOOT

QX42-S1

QJ71C24-R2 QJ61CL12 QJ61BT-11

PULL

PULL

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8USB

ON

For Easy usage [No need of parameter settings]Troublesome network parameter setting is unnecessary. The communication speed setting is required for the master module only.

For high-speed control [fast response]When 64 stations are connected, link scan time is a maximum of 1.2 ms(at 2.5Mbps), achieving excellent fast response performance.CC-Link/LT Link Scan Time (at communication speed of 2.5 Mbps) 16-point mode Link scan time (ms) 8-point mode 4-point mode 2.5 2.0 1.5 1.0 0.5 0 0 20 40 60

For High noise-resistance [Complying with EMC Directives]Max. 2.5 Mbps Max. 2.5 Mbps Max. 2.5 Mbps

CC-Link/LT also inherits the feature of CC-Link, complies with EMC directives for noise-resistance.

FX3UC-32MT-L

T

CL2X16-D1M1

V

CL2X16-D1M1

V

CL2X16-D1M1

V

1 S3DCL1PAD1

C X1L D- 2CL1PAD1

1 S 3D

C X1 L D- 2

1 S3D

C X1L D- 2

CL2Y8-TP1B2

CL2Y8-TP1B2

CL2Y8-TP1B2

For Efficient use of I/O points [No wasting surplus I/O points]The adoption of the point mode (4, 8, 16 points) enables I/O assignment that makes full utilization of the available number of points.

Number of stations

CC-LinkControl methods I/O control + intelligent distribution Dedicated fixed cable, dedicated flexible cable, dedicated built-in power supply RXRY: 8192 points each, RWr: 2048 words, RWw: 2048 words (Ver2.0) Screw terminal block, spring terminal block, e-CON, Push-in connector, waterproof connector, 40-pin connector 1200 m (at 156 kbps) Extendable up to 13.2 km when repeater is used

CC-Link/LTPWCC-Link L RUN L ERR. CC-Link/LT L RUN L ERR. L ERR.1 2 3 4

CC-LinkSTATION NO. 40 20 10 8 4 2 1 TST MODE B 4 2 1 RATE NC 2 1 2 1 2 1 7 8 9 10 1 2 3 4 5 6 7 8 B RATE

CC-Link/LTNOS

5

6

I/O control

AJ65SBT-CLBCC-Link

ON

CC-Link/LT

Max. 2.5 MbpsDedicated flat cable, VCTF (Vinyl Cabtire Code), dedicated flexible cable

Max. 2.5 MbpsFX3UC-32M T-LT

Max. 2.5 Mbps

Cable

Maximum number of link points I/O Module Line-up

RXRY: 1024 points eachINST.No. LINK/PW

CL2X16-D1M1V1234567 8ON

OC .MMINST.No.

O .MMCL2X8-D1C3V1234567 8ON

CINST.No.

CL2X16-D1M1V1234567 8ON

OC .MM

LC 2X1 1DS3D

LINK/PW

S3 D

2 1D-

X1 L

C

LINK/PW

S3 DPW

2X 1D-

1LC

PW

Screw terminal block, spring terminal block, e-CON, MIL connector, cable connector Trunk: 500 m Branch: 200 m (at 156 kbps)

L RUN

L ERR.

DLH

DLH

PW0 1 2 3 4 5 6 7 8 9 A B C D E F

L RUN L ERR.

PW

L RUN L ERR.

PW0 1 2 3 4 5 6 7 8 9 A B C D E F

L RUN L ERR.

0

1

2

3

4

5

0

6

1

7

2

3

4

5

0

6

1

7

2

3

4

5

6

7

ONL UR 0N WP G42

ONUR 0N P LW G42

ONUR 0N LW P

OUTY0 Y1 Y2 Y3 Y4 Y5 Y6 Y7

40 20 10 8 4 2 STATION NO.

11 0.5 ms 1.5 ms

TUO0 2+ V4 Y

NI0X

OUTY0 Y1 Y2 Y3 Y4 Y5 Y6 Y7

40 20 10 8 4 2 STATION NO.

11 0.5 ms 1.5 ms

0Y 2+ V4

TUO

NI0X

OUTY0 Y1 Y2 Y3 Y4 Y5 Y6 Y7

DLH40 20 10 8 4 2 STATION NO.

CL2Y8-TP1 B2

TS ITA204 NO 0 N 01 .O 4 8 12

CL2Y8-TP1 B2

TS ITA204 NO 0 N 01 .O 4 8 12

L RUN

L ERR.

CL2Y8-TP1

B2

TS ITA204 NO 0 N 01 .O 4 8 12

11 0.5 ms 1.5 ms

0Y 2+ V4

TUO

NI0X

G42

Max. cable distance

Parameter setup

GX Developer

Not required

For rapid startup of systems [easy installation]Using dedicated connectors and cables can reduce wiring works. Communication connectors are a male/female integrated type and available for all trunk and branch lines.

Cable specific to application requirements [extensive lineup of cables]Dedicated flat cable, VCTF cable and Dedicated flexible cable.

Improving reliability [prevention of miswiring]Dedicated cable shape is designed to prevent miswiring. The orange wire is visible when inserted the wrong way. Orange indicates NG (No Good).

Number of link points per station

RXRY: 32 points each, RWr: 4 words, RWw: 4 words RXRY: 128 points each, RWr: 32 words, RWw: 32 words Bus topology T-branch topology Star topology

Max, 16 points (in 16-point mode)

Dedicated flat cableNetwork topology

Oh!! Flexible!!T-branch topology

"Snap!"

VCTF cable

Dedicated flexible cable

7

8

For hose in design, production and maintenance

CC-Link & CC-Link/LT provide solutions for each challenge in the field.

More functions...CC-Link"I want a flexible production system."

Engineering section(P11, P12)

At assembly...CC-Link CC-Link/LT

Production section(P13, P14)

Preventing troubleCC-Link CC-Link/LT "I need network testing for preventive maintenance." CC-Link"I want to do network maintenance from sites away from the PLC master."

Maintenance section(P15, P16)

"I want to arrange devices as I desire."

CC-Link"I need complex control features."

CC-Link

CC-Link/LT

"I need assembly/ disassembly to be easy."

CC-Link"I want to connect lots of analog devices."

CC-Link

CC-Link/LT

"I need high noise resistance."

At testing/operation...CC-Link"I want a distributed control system."

CC-Link"I want to prevent trouble from foreign substances"

CC-Link "I want to connect between lines." "I want a network for building management." CC-Link

When trouble occurs... (troubleshooting)CC-Link"I don't want to stop my system."

CC-Link"I need quick check-up."

Each person in charge of engineering, production and maintenance has his/her own challenge. CC-Link and CC-Link/LT responds to each challenge with a solution. CC-Link is an establishined open field network originatied from Japan. Fully inheriting the CC-Link concept, CC-Link/LT is specifically designed as a sensor level network. "I want this." "I need this." CC-Link & CC/Link/LT provides a function for each challenge on the network.

"I want to connect HMIs and 'ANDONs.' "

CC-Link

CC-Link/LT

CC-Link

CC-Link/LT

"I want to save wiring time and cost."

CC-Link"I want to connect drives and servos."

"I need easy troubleshooting."

CC-Link/LT"I need high-speed sensor inputs."

More simple...CC-Link"I want to connect lots of devices."

CC-Link"I need an easy network."

CC-Link/LT"I want to use remote I/O."

CC-Link/LT"I need widely used cables."

More secure...CC-Link"I need high noise resistance."

CC-Link"I need various devices on a single network."

CC-Link"I want to export our facilities and machinery overseas."

The solutions provided by CC-Link & CC-Link/LT begin from here.

9

10

CC-Link ensures..."I want a flexible production system." CC-Link is a high-speed and high-capacity network.CC-Link is a high speed field network that can handle both control and information together. High-speed/High-capacity data transmissionQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

"I want to connect between lines." "I want a network for building management." The total extended distance of the CC-Link cable is 1,200 m, and can be extended up to 13.2 km when repeaters are used.CC-Link total extended distance can be as long as 1.2 km*. The transmission distance can be extended up to 13.2 km* when T-branch repeaters are used.* Maximum transmission distance when transmission speed is set to 156 kbps.

"I want to connect HMIs and 'ANDONs.' " CC-Link can connect HMIs and ANDONs by transient transmission.CC-Link simplifies data transfer to HMIs and ANDON with transient transmission (up to 960 bytes) and cyclic transmission.

"I need complex control features." CC-Link guarantee consistent communication time.The cyclic transmission time is not affected by irregular message transmission to the HMI products. It is possible to achieve highly stable control. CC-Link Link Scan Time (at communication speed of 10 Mbps)6Remote I/O station only Remote device station only (when all stations 1 station is occupied) Local node/intelligent device station only (when all stations 1 station is occupied)

"I need an easy network." CC-Link parameter setting can be done with only GX Developer.

Overall cable distance of CC-Link10010 Mbps When a repeater is not used When optical repeater (GI cable) is used When a repeater (T-branch) is used

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

67 8

A J65BTB1-16DPW L RUN SD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4

67 8

F012

3456

PULL

USB

PULL

Data capacity

Remote I/O (RX, RY)=8192 points each Remote register (RWw)= 2048 words (RWr)=2048 words (when Ver2.0 is used)

"I want to connect lots of analog devices." supports an extra broader range of needs.CC-Link Ver.2 can control maximum eight times the data capacity compared with earlier CC-Link compatible products. CC-Link Ver.2 compatible analog modules are applicable to process control. CC-Link Ver2.0-compatible analog module

F012

3456

PULL

USB

PULL

"CC-Link V2 has a double module connection capacityQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR Q61P-A1 POWER

456

456

456

78

78

F012

F012

3456

3456

PULL

PULL

Up to 42 modules can be connected.

USB

1 2 3 4 5 6 7

USB

PULL

PULL

CC-Link/LT ensures..."I need high-speed sensor inputs." CC-Link/LT provides fast response.When 64 stations are connected, the link scan time is a maximum of 1.2ms (at 2.5Mbps). Select 2.5Mbps, 625kbps or 156kbps depending on the transmission distance. CC-Link/LT Link Scan Time (at communication speed of 2.5 Mbps)16-point mode Link scan time (ms) 8-point mode 4-point mode 2.5 2.0

1.5 1.0 0.5 0 0 20 40 60 Number of stations

"I want to use remote I/O." CC-Link/LT is not required to make parameter setting.Troublesome network parameter setting is unnecessary. The communication speed setting is required for the master module only. There is no need to set the communication speed on the remote station.

11

CDE

23

23

CDE

23

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

CDE

23

456

78

23

Ver 1.0

456

CDE

23

45

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

0

1

2

3

4

5

6

7

8

9

A B

C D E F

6 5 4

5 4 3 2 1 0 0 20 40

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

1 2 3 4 5 6 72DB 4 SLD 6 8

10

12

14

16

18

20

22

24

26

(FG)

4,300 1,100 160

The total programming tool "GX Developer" with improved operability. Makes full use of the advantages of Windows R and enables you to set CC-Link parameters without a program.

Link scan time (ms)

0 9 1 0 9 1AB 789

45

5 Mbps

4,480 1,760 400 5,200 4,400 900

"I need a reliable network." CC-Link achieves high reliability with dedicated cables.6,700 9,900 7,600 13,2004,000 6,000 8,000 10,000 12,000 14,000 (m)

2.5 Mbps

60 Number of units [units]625 kbps

"I want a distributed control system." CC-Link realizes simple distributed control.CC-Link provides highly stable cyclic transmission, which enables N:N communication between controller masters or local stations. This N:N communication method between controllers realizes a distributed control system for each system. Simple controller communicationQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

1,200156 kbps 0 2,000

CC-Link uses dedicated cables that support high-speed transmission up to 10 Mbps. These cables are also highly noise-resistant. CC-Link dedicated cableDedicated fixed cable

"I want to connect lots of devices." can control up to 8192 points and 4096 words.Dedicated high flexible cable

Up to 21 modules can be connected.

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

78

0 1 2 3 4 5 6 7 8 9 A B C D E F

1 2 3 4 5 6 7

CC-Link Ver2.0 can transmit a maximum of eight times the data capacity compared with earlier CC-Link compatible products. Comparison of communication data

9 01AB 789

Dedicated flexible cable

9 01

Ver 1.0Q25HCPUMODE RUN ERR USER BAT BOOT

Remote I/O Remote register Remote I/O Remote register

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

(RX, RY) = 2048 points (RWw) = 256 words (RWr) = 256 words (RX, RY) = 8192 points each (RWw) = 2048 words (RWr) = 2048 words

Built-in power cable

78

9 01AB 789

9 01

9 01

9 01AB 789

1 2 3 4 5 6 7

CC-Link also lets you... "I need widely used cables." CC-Link/LT specifies cables to application requirements.Dedicated flat cable, VCTF cable and dedicated flexible cable are available.Dedicated flat cable VCTF cable Dedicated flexible cable

"I want to connect drives and servos." CC-Link allows GX Configurator-CC to read and write drives and servo parameters without a program, and perform monitoring and testing. "I need various devices on a single network." Diverse range of products supplied from many partner manufacturers. "I want to export our facilities and machinery overseas." CC-Link complies with various safety standards including UL standards.* For details, refer to MELFANSweb.

12

I want to arrange devices as I desire. CC-Link allows flexible installation.T-branch repeaters, wireless optical repeaters, optical repeaters, and repeater hubs are available with CC-Link. They enhance the freedom of application even at 10 Mbps.Repeater hub1 4 5 6 7 8

I need assembly/ disassembly to be easy. CC-Link family remote I/O modules occupy a small footprint.Compact type remote I/O modules with 32, 16, 8, 4, and 2 I/O points are available. They can be mounted in six different directions, including ceiling mounting, front mounting, and flat surface mounting, and selected according to the environment where they are to be mounted and the application. Direct mounting on machines in 6 directions

I want to prevent trouble from foreign substances CC-Link protective cover protects I/O terminals.The protective cover can be easily attached and removed. The transparent material allows you to check the LEDs and wiring conditions.

CC-Link family products allows easy connection.By using online connectors for communication and power supply, it is possible to replace modules without stopping the communication. Online connectorPush-in connector type with terminator A6CON-TR11

AJ65FBT-RPHPOWER RUN SD RD L1 RD L2 RD L3 RD L4 RD

UNIT POWER

ERR. 156k 625k 2.5M 5M 10M L5 RD L6 RD L7 RD L8 RD

Master station

LINK1

LINK5

LINK2

LINK6

LINK3

LINK7

LINK4

LINK8

Remote I/O station, remote device station Intelligent device station, local station, etc.

I need quick check-up. CC-Link ensures easy setup and startup.Front mounting Front mounting

CC-Link's auto-startup function allows you to start up the network without the need to set network parameters.

Online connector for communication A6CON-LJ5P

Flat surface mounting

Ceiling mounting

I want to save wiring time and cost.Dedicated connectors of CC-Link family are designed to reduce wiring works, cost and wiring mistakes.

Specific connection to application requirements

Screw terminal block typeFinger protection Self-up screw

Spring clamp terminal block type

40-pin connector type

Waterproof connector type (M12)

PW

CL2Y8-TP1B2L RUN L ERR.

0

1

2

3

4

5

6

7

ON40 20 10 8 4 2 STATION NO. DC24V DC24V Y0 Y1 Y2 Y3

1

HLD

OUTPW

CL2Y8-TP1B2L RUN L ERR.

Y4

0Y5 Y6 Y7

1

2

3

4

5

6

7

DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24V DC24V Y0

ON40 20 10 8 4 2 STATION NO. Y1 Y2 Y3

1

HLD

OUTPW

CL2Y8-TP1B2L RUN L ERR.

Y4

Y5

0Y6 Y7

1

2

3

4

5

6

7

DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+ DC24V DC24V

ON40 20 10 8 4 2 STATION NO. Y0 Y1 Y2 Y3

1

HLD

OUT

Y4

Y5

Y6

Y7

DC24G DC24G COM+ COM+ COM+ COM+ COM+ COM+ COM+ COM+

Terminal block Round crimp terminal

The round crimp terminal can be directly connected with the self-up screw by simply unfastening the terminal block screw.* The specifications depend upon a product.

Spring clamps allows for quick and easy connectivity.

This type provides an easy and economical way of wiring.

The waterproof type remote I/O module is housed in a protective structure conforming IP67. therefore it can be used without worry in an environment where water is present.

Sensor connector (e-CON) type

Push-in connector type

MIL connector type

Cable typeConnector

Simplified stopper structure Single wire Connector Soldering, wire sheath peeling, and screwing are no longer required. Open sensor connector (e-CON) To sensor, valve Press in.

CL1-HLD To I/O equipment or terminal block conversion unit Switch Sensor

Utilizing the industry-standard e-CON, sensors can be replaced individually.

This connector adopts a lock mechanism that is easy to lock and unlock. You can connect single wires by simply pushing in the connector.

This is the industry's smallest connector in its class, and can be easily connected to a relay terminal or terminal block conversion module.

This is the industry's smallest connector in its class. Suited to fit compactly into main trunking ducts.

13

14

Before trouble occurs... (preventive maintenance)"I need network testing for preventive maintenance." CC-Link family products provides one-step-ahead preventive maintenance.It is possible to check the data link status using special relays and registers. Hardware and line connection can be tested via offline tests.

When trouble occurs... (troubleshooting)"I don't want to stop my system." CC-Link provides enhanced RAS functions.CC-link realizes minimal system shutdowns by "error invalid station setting," "slave station isolation," "automatic return," "standby master station," and "2-piece terminal block". In the online mode, this setting temporarily prevents modules specified on GX Developer from being treated as data link faulty stations. Slave station isolationMaster stationQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

"I want to do network maintenance from sites away from the PLC master." CC-Link provides remote operation functions.By using the peripheral device connection module (AJ65BT-G4-S3) into the CC-Link system, it is possible to do network maintenance from sites away from PLC master. G4 module

Standby master stationMaster stationQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

Standby master stationQJ71BR11MNG D.LINK RD ERR RUN T.PASS SD ERR MNG D.LINK RD ERR Q61P-A1 POWER MODE RUN ERR USER BAT BOOT

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR

Q25HCPU

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

456

456

F012

F012

3 456

3456

PULL

PULL

USB

1 2 3 4 5 6 7

USB

PULL

PULL

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

F012

3456

PULL

USB

PULL

There is no need to move the PC to where the PLC CPU is installed.A J65BTB1-16DPW L RUN SD RD L ERR. 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 B RATE 0 1 2 3 0 1 2 3 4 5 6 7 8 9 A B C D E F

6 5 4

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

(FG)

PCOnline operation can be performed from programming software to any PLC at remote locations.

PC

PC

Remote station

Automatic returnMaster stationQ25HCPUQ61P-A1 POWER MODE RUN ERR USER BAT BOOT

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

F012

3456

PULL

USB

PULL

AJ65BT-G4-S3Q64P POWER

PCPW L RUN 0 1 2 31 DA 3 DG 5

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 PW L RUN

4

5

6

7

8

9

A B

C D E F

6 5 4

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

Q25HCPUMODE RUN ERR USER BAT BOOT

Q64P

Q172CPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

POWER

Q25HCPUMODE RUN

Q64P

Q172CPUMODE RUN ERR USER BAT BOOT

QJ71C24-R2

QJ71LP21-25

POWER

Q25HCPUMODE RUN

(FG)

Q172CPUMODE RUN ERR USER BAT BOOT

QJ61CL12

QJ71C24-R2

QJ71LP21-25

QJ61BT-11

QJ61CL12

QJ71C24-R2

ERR USER BAT BOOT

QJ61BT-11

QJ61CL12

ERR USER BAT BOOT

QJ61BT-11

Remote station

FRONT

PULL

SSCNET CH2

PULLPULL

CH1

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

ON

FRONT

PULL

SSCNET CH2

PULLPULL

CH1

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

ON

FRONT

PULL

SSCNET CH2

PULLPULL

CH1

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

ON

USB USB

USB USB

USB USB

RS-232

RS-232

RS-232

* When connecting offline stations on CC-Link/LT, make sure that the PLC CPU is in a STOP status.

Local station

Local station

Local station

CC-Link

"I need easy troubleshooting." CC-Link family Networks can be easily checked by GX Developer.The status of the CC-Link and CC-Link/LT networks can be monitored by just GX Developer.

"I need high noise resistance." CC-Link family compatible products are highly noise resistant guaranteed by conformance testing.A conformance test is conducted for all products sold by CLPA partners. the test includes a power supply noise test and a bundle noise test. Power supply noise test (AC/DC) Tested productsQ61P-A1

Bundle noise test Master stationQ25HCPUPOWER MODE RUN ERR USER BAT BOOT

Tested productsQJ71BR11MNG D.LINK RD ERR RUN T.PASS SD ERR MNG D.LINK RD ERR Q61P-A1

Master stationQ25HCPUPOWER MODE RUN ERR USER BAT BOOT

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

F012

F012

3456

3456

PULL

PULL

USB

1 2 3 4 5 6 7

USB

PULL

PULL

Communication line (CC-Link)

Communication line (CC-Link)

15

CDE

23

456

CDE

23

456

78

78

23

23

Power line

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

456

78

78

1 2 3 4 5 6 7

CDE

23

456

78

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

1 2 3 4 5 6 7

PW L RUN

0

1 DA

3 DG

5

+24 V

2DB

4 SLD

6

Remote station

CDE

23

456

78

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

1 2 3 4 5 6 7

Station is made offline when a station error occurs, and the data link is continued on normal operating stations.1 DA 3 DG 5

A J65BTB1-16DPW L RUN SD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 PW L RUN

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4 PW L RUN

0

1

2

3

4

5

6

7

8

9

A

B C D E F

0

1

2

3

4

5

6

7

8

9

A B C D E F

6 5 4

6 5 4

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

(FG)

(FG)

Remote stationA J65BTB1-16DPW L RUN SD RD L ERR. 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 B RATE 0 1 2 3 PW L RUN SD RD L ERR. 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4

Remote station

A J65BTB1-16D

B RATE 0 1 2 3

0

1

2

3

4

5

6

7

8

9

A B C D E F

0

1

2

3

4

5

6

7

8

9

A B C D E F

6 5 4

6 5 4

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

(FG)

(FG)

Remote station

Remote station

By setting a local station as a standby master station, the data link can be continued even if an error occurs in the master station.

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

Stations disconnected from the data link due to errors are automatically retuned to the data link once they return to normal status.

The "2-piece terminal block" allows modules to be replaced without stopping the CC-Link system.

Module fixed side

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 PW L RUN

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4

0

1

2

3

4

5

6

7

8

9

A B

C D E F

0

1

2

3

4

5

6

7

8

9

A B C D E F

6 5 4

6 5 4

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

(FG)

(FG)

1

2

3

4

5

6

7

8

9

A B

C D E F

6 5 4

724G

9

11

13

15

17

19

21

23

25

27

Remote station

Remote station

8

10

12

14

16

18

20

22

24

26

(FG)

2-piece terminal block Cables

Modules can be separated by unfastening the screws on both edges of the terminal block with the cable still connected.

CDE

23

456

78

2378

CDE

23

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

78

9 01AB 789

9 01

9 01

9 01AB 789

1 2 3 4 5 6 7

9 019 01AB 789

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 2 8 3 3 7 6 5 4

0

1

2

3

4

5

6

7

8

9

A B

C D E F

6 5 4

1 DA

3 DG

5

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

(FG)

Remote station

9 01 9 01AB 789

9 01 9 01AB 789

9 01 9 01AB 789

16

Case Study

"CC-Link is superior to existing networks" Realize the advantages of CC-Link.Mr. A from the engineering sectionCASE

CASE

1

2

Mr. B from the production section

"My current network distance is limited to 100m, and the transmission speed is unstable."Mr. A plans to expand his factory. The first challenge is total cable distance and communication stability. What interested him is that the network distance covered by the CC-Link network can be increased up to 900m at 625kbps, and transmission time is stable as well. Feature 1 CC-Link is high-speed network and total cable distance is long distance. Feature 2 CC-Link is a consistent network. Transmission speeds and overall Network distance of other companies' networksOther network100 m

"Trunk cables and branch cables in the current network are different. Furthermore, trunk cables are expensive."Mr. B is in charge of production engineering. He has been worried about utilization and high cost of the existing network. Therefore, he collected CC-Link information and compared it with other networks. Feature 1 CC-Link is flexible to install. Cable comparison Feature 2 CC-Link is reasonably priced.

CC-Link scan time guide

(at communication speed 10 Mbps)

Item Cable diameter Trunk/ Branch Total cable length (no repeater)

CC-Link 7 mm Trunk and branch Max. 1200 m (156 kbps)

Other network Thick cable: 12 mm Trunk Max. 500 m (125 kbps) Thin cable: 7 mm Branch Max. 100 m (125 kbps) (250 kbps) (500 kbps)

At 156 kbps900 m

Remote I/O station only Remote device station only (when all stations 1 station is occupied) Local node/intelligent device station only (when all stations 1 station is occupied)6

Link scan time (ms)

5 4 3 2 1 0 0 20 40 60 Number of units [units]

At 600 kbps

"It is stressful to design the necessary power supply capacity of a network."Mr. B used to be bothered by complicated calculations for the required power capacity. He soon learned that such bothersome calculation was not necessary. Feature 3

CC-Link frees you from the need of calculation of the power supply capacity.

"Our factory's networks are complex because they use various protocols. How about CC-Link?"CC-Link eliminates the need to use different protocols. Feature 3

Protocol comparisonCC-Link Broadcast polling system Other networks Protocol A Protocol B

CASE

Mr. C from the maintenance section

3

"It concerns me that conformance testing is not mandatory in my current network."Reliability is the most important for him. He was pleased that the conformance test guaranteed the high noise resistance of CC-Link.

CC-Link is reliable because the conformance test is mandatory.

CC-link is a single protocol.

"It takes too long to reconnect network stations."Regarding this issue, Mr. A learned that CC-Link compatible products quickly return to the network, and began to feel more attraction to CC-Link. Feature 4Protocol C Protocol D

CC-Link offers quick return to the network system.Distributed control by simple inter-controller network

"I also need distributed control."Also, using CC-Link, he easily realized "distributed control by establishing communication between controllers". Feature 5Q61P-A1 PULL

Master stationQ25HCPUPOWER MODE RUN ERR USER BAT BOOT

Local stationQJ71BR11MNG D.LINK RD ERR RUN T.PASS SD ERR MNG D.LINK RD ERR Q61P-A1 POWER MODE RUN ERR USER BAT BOOT

Local stationQJ71BR11MNG D.LINK RD ERR RUN T.PASS SD ERR MNG D.LINK RD ERR Q61P-A1 POWER MODE RUN ERR USER BAT BOOT

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR

Q25HCPU

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR

Q25HCPU

QX10

QJ61BT11RUN MST SD ERR. L RUN S MST RD L ERR

QX41

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

QJ71BR11RUN T.PASS SD ERR MNG D.LINK RD ERR

456

456

456

456

F012

F012

F012

3456

3456

3456

PULL

PULL

USB

1 2 3 4 5 6 7

USB

1 2 3 4 5 6 7

USB

PULL

PULL

PULL

CC-Link is simple cotroll level network.1 DA 3 DG 5

A J65BTB1-16DPW L RUN SD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4 PW L RUN

0

1

2

3

4

5

6

7

8

9

A

B C D E F

0

6 5 4

7 +24 V24G

9

11

13

15

17

19

21

23

25

27

1 DA

3 DG

5

+24 V

2DB

4 SLD

6

8

10

12

14

16

18

20

22

24

26

2DB

4 SLD

6

(FG)

Remote I/O HMI

Remote I/O

17

CDE

(FG)

23

456

78

78

78

23

CDE

23

23

CDE

23

23

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

0 1 2 3 4 5 6 7 8 9 A B C D E F

456

78

78

78

9 01

9 01

9 01

9 01

9 01AB 789

9 01AB 789

AB 789

1 2 3 4 5 6 7

A J65BTB1-16DSD RD L ERR.

B RATE 0 1 2 3 4 STATION NO. X10 X1 0 1 9 0 1 2 8 2 3 7 3 6 5 4

1

2

3

4

5

6

7

8

9

A B C D E F

6 5 4

724G

9

11

13

15

17

19

21

23

25

27

8

10

12

14

16

18

20

22

24

26

18

Material handling application

Semiconductor production application

Improved workability by repeaters

High-speed transmission

Connection of various devices (Inverter, HMI)

High noise resistance

Cable specific to the application requirement.

Wire saving Small footprint

Seamless communication using bridges

Compliant to EES.

Building management application

Parking lot application

The total cable distance up to 13.2 km by using repeatersMELSECNET/H

High speed transmission

Distributed control

Wire saving Small footprint

Seamless communication between Ethernet, MELSECNET/H and CC-LinkEthernet

Parameter-free setup work

Building monitoring rooms

Easy installation and setting up

19

20

The CC-Link compatible product lineup is expanded!

Introduction of New ProductsRemote I/O modulesSource typeAJ65SBTB1B-16TE1 AJ65SBTB1-32TE1 AJ65SBTB1-32DTE1P.45 P.45 P.52

Output modules and I/O composite module with source type output form are added for the screw terminal block type.

System Configuration Example Product informationMaster/Local modules Remote I/O modules Analog modules High-speed counter modules Positioning modules Peripheral device connection modules RS-232 interface modules PC interface boards Repeater modules Optional parts

23

Repeater modulesSpring clamp typeAJ65BTS-RPHP.123

A spring clamp terminal type repeater hub module, which realizes work hour savings, is added.

21

22

Support

Technical Information

Other/ Software

Embeded

Option

Repeater

25 31 91 107 109 113 115 117 119 133

PC interface RS-232 I/F Peripheral device Positioning High-speed connection counter

Analog

Remote I/O Master/Local

System Configuration ExampleMaster/Local modulesP.25

Analog modulesA1SP60 A1SP60 A1SJ61BT11 A1SJ61BT11 AD35ID1

P.91

CC-Link-CC-Link/LT bridge modulesPW CC-Link L RUN L ERR. CC-Link/LT L RUN L ERR. L ERR. 1 2 3 4 CC-LinkSTATION NO. 40 20 10 8 4 2

RUN ERR. L RUN L ERR. SD RD

IN 0 1 2 3 4 5 6 7

POWER

10 11 12 13 14 15 16 17

P.147

FX2N-32MR

IN 10

0 1 2 3 4 5 6 7 11 12 13 14 15 16 17

POWER RUN BATT.V PROG.E CPU.E

FX2N-16CCLMRUN ERR. L RUN L ERR. SD RD RD

Partner productQJ71C24-R2 QJ61CL12 QJ61BT-11

Q64P POWERCC-Link/LT1 TST MODE B 4 2 1 2 RATE NC 1 2 1 2 1 7 8 9 10 1 2 3 4 5 6 7 8 B RATE NOS

Q25HCPUMODE RUN ERR USER BAT BOOT

Q172CPUMODE RUN ERR USER BAT BOOT

QJ71LP21-25

5

6

AJ65SBT-CLBCC-Link

ON

CC-Link/LT

FRONT

PULL

SSCNET CH2

PULLPULL

CH1

SW I/O 1 POINTS 2 3 B RATE 4 5 MODE 6 7 TEST 8

ON

USB USB

RS-232

Cables Robots Solenoid valves HMI Thermostats ID controllers, etc.

PC interface board

P.117

Refer to the CC-Link Partner Association catalog

OthersP.136To CC-Link/LT products pages

P.199

0

1

2

3

4

5

6

7

OUTX0 X1 X2 X3 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7

1

Remote I/O modules

P.31

Repeater modulesSupporting various types of wiring such as T-branching or cable extension Thin, waterproof type repeater hub Repeater (T-branch)POWER RUN SD RD ERR.FG FG NC 24G +24V

P.119

Embedded modules P.191

A lineup of products supporting various applicationsPW L RUN L ERR X0 1 2 3 4 5 6 7 Y8 9 A B C D E F

ONDA DB DG

STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1

+24V SLD

24G (FG)

A J65SBTB1-16DTX0 X1 X2 X3 X4 X5 X6 X7 Y8 Y9 YA 9B YC YD

YE YF

COM+ COM-

Communication LSI dedicated to CC-Link P.197 FX Series interface block P.201 AC servo amplifier/interface module P.202 Inverters P.203 GOTes P.205 Numerical control units P.207 Industrial robots P.208 Breaker P.209 Energy Measurement Module P.210 Power measurement module P.211 Multi-circuit power meter module P.212 Protective relay P.213

AJ65BTS-RPHRD1LINK1

B RATERD2LINK2

+24V 24G NC(FG) (FG)

LINK

IN/OUT

RD3LINK3

0 1 RD4LINK4

RD5LINK5

RD6LINK6

RD7LINK7

4 RD8LINK8

2 3

DA DB DG SLD

Spring clamp terminal block type repeater hub

Embedded I/O modules P.191 Interface boards P.195

Special function modules

P.107

AJ65VBTCE3-16

Optional partsD

P.187

High-speed counter modules P.107 Positioning modules P.109 Peripheral device connection modules P.113 RS-232 interface modules P.115

SoftwareWireless optical repeater Optical repeater

P.199

23

24

Product information

Master/Local modules

Master/Local modulesOverviewThe available master module lineup accommodates all MELSEC CPU types. For Q series QJ61BT11NQ master

Model namesProduct name Master/local module for Q series Master/local module for QnA seriesP.

Model QJ61BT11N A1SJ61QBT11 A1SJ61BT11 FX2N-16CCL-M

Related manual User's Manual SH-080394E (13JR64) User's Manual SH-66722 (13J873) User's Manual IB-66721 (13J872) User's Manual JY992D93101 (09R710)

P.

27

For QnAS series A1SJ61QBT11QnAS master

29

Master/local module for AnS series Master/local module for FX series

For AnS series A1SJ61BT11AnS master

P.

30

For FX series FX2N-16CCL-MP.FX master

31

25

26

Support

Technical Information

Other/ Software

Embedded

Option

Repeater

PC interface

RS-232 I/F Peripheral device Positioning High-speed connection counter

Analog

Remote I/O Master/Local

Master/Local Remote I/O Analog High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embeded Other/ Software Technical Information Support

Product information

Master/Local modules

Master/Local modulesQ masterMaster/Local Remote I/OCPU module

External dimensionsQJ61BT11NRUN MST SD ERR. L RUN S MST RD L ERR.

External dimensionsA1SJ61QBT11RUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR. SW M/S PRM TIME LINE SD RD E R R O R

4 5 6

STATION NO.

7 89 0 1

STATION NO.

MODE 8 9ABCD 345

456

X10

7 84 5 6

X1

8 9A

BCD

5 6 7 8

1/2 1/4

3/4 2/3

130

98

67

B RATE0 156K 1 625K 2 2. 5M 3 5M 4 10M

DA

NC NC DA SLD DB(FG)

1 2 3 4 5SLD DB

NC DG NC

4 5 6 7

DG

6 7

NC

8 9

Internal current consumption: 0.46A Weight: 0.12kg90 27.4

Internal current consumption: 0.4A Weight: 0.25kg6.5Unit: mm

(FG) 10

A1SJ61QBT11

93.6

23.9

34.5Unit: mm

Applicable CPUConnectable CPU models QCPU basic model QCPU high performance model Process CPU Redundant CPU Network module Q00JCPU,Q00CPU,Q01CPU Q02CPU,Q02HCPU,Q06HCPU,Q12HCPU,Q25HCPU Q12PHCPU,Q25PHCPU Q12PRHCPU, Q25PRHCPU QJ72LP25-25, QJ72LP25G, QJ72BR15 Max. No. of mountable modules GX Developer setting Dedicated instruction setting 2 2 4 64 4 64 4 4 -

Applicable CPUCPU module Network module Connectable CPU models Q2ASCPU (S1), Q2ASHCPU (S1) A1SJ72QLP25, A1SJ72QBR15

Part names and settingsQJ61BT11NRUN MST SD ERR. L RUN S MST RD L ERR.

Part names and settingsLED indication

QJ61BT11N2 3

23

X10

7 8

X1

Set the module's station No. Master station: 0 Local station: 1 to 64

4 56

No. Name 0 Online 1 2

SD RD

SD RD

LED indicationThe data link state can be checked by the LED states. LED name Description ON: The module is normal RUN ERR. ON: Communication error at all stations Flashing: Data link error occurred at some station. ON: Set as the master station MST S MST ON: Set as the standby master station L RUN ON: Performing data link L ERR. ON: Communication error (its own station) SD ON: Sending data RD ON: Receiving data

4 56

456

8 9A

7 8

BCDEF0 1 2

Transmission rate/Mode setting switchSet the module's transmission rate and operation mode. No. 0 1 2 3 4 5 6 7 8 9 A B C D E F Mode Transmission rate 156kbps 625kbps 2.5Mbps Online 5Mbps 10Mbps 156kbps Line test 625kbps When station NO. setting switch is 0 : Line test 1 2.5Mbps When station NO. setting switch is 1 to 64 : 5Mbps Line test 2 10Mbps 156kbps 625kbps 2.5Mbps Hardware test 5Mbps 10Mbps Setting is inhibited.

4 56

67

456

8 9A

67

MODE

0 156K 1 625K 2 2. 5M 3 5M 4 10M

7 8

NC 1 NC 2 3 NC 4 5 NC 6 7 NC 8 9

DA

DB

456

DA SLD DB(FG)

2 3 4 5 6 7

10

DG

Transmission rate setting switch23

A1SJ61QBT11

Terminal blockConnect the CC-Link dedicated cables for the data link.

Terminal blockConnect the CC-Link dedicated cables for the data link.

No. 0 1 2 3 4

Transmission rate 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps

1 625K 2 2. 5M 3 5M 4 10M

27

28

Support

0 156K

456

Set the module's transmission rate.

78

B RATE

Technical Information

23

X 1

78

23

NC

X 10

456

NC

1

Set the module's station No. Master station : 0 Local station : 1 to 64 Standby master station : 1 to 64 * When the mode switch is set to the remote I/O network mode, set the number of connected modules.

78

DG

* Supported by the A1SJ61QBT11 hardware version G or later.

SLD

For other versions, the number of occupied stations is set by SW5 only. OFF: 1 station occupied ON: 4 stations occupied SW6 must be always OFF since its use is not allowed.

(FG)

Other/ Software

Station No. setting switch

STATION NO.901

Embedded

BCDEF0 1 2

B RATE

23

34 5

X1

78

23

MODE

X 1

78

SW OFF 2 3

ON

1 M / L S. M

SW OFF ON 1 M / L S. M 2 3 4 CLR HLD 5 6 1/2 1/4 3/4 2/3

Conditions setting switchNo. SW1 Switch Status OFF: Master/Local station Station type ON: Standby master station SW4 Data input from data OFF: Clear ON: Hold link error station No. of occupied stations SW5 SW6 SW5 OFF OFF 1 station SW6 No. of occupied OFF ON 2 stations* stations ON ON 3 stations* ON OFF 4 stations Setting item

4 CLR HLD 5 6 7 8 1/2 1/4 3/4 2/3

Option

F0 1

23

23

X 10

456

STATION NO. X10

7 890 1

LED name Description ON: The module is normal RUN ON: Communication error for all stations ERR. Flashing: Data link error occurred at some station. MST ON: Set as master station S MST ON: Set as standby master station LOCAL ON: Set as local station CPU R/W ON: Communicating with PLC CPU (FROM/TO) ERROR Lights up when an error occurs L RUN ON: Performing data link L ERR. ON: Communication error (its own station) SD ON: Sending data RD ON: Receiving data

STATION NO.

MODE 456

78

789

Description Select this when performing the data (Remote network mode) link in the remote network mode. Select this when performing the data Online (Remote I/O network mode) link in the remote I/O network mode.) Offline The data link is disconnected.

Repeater

F0 1

RUN MST SD ERR.

L RUN S MST RD L ERR.

STATION NO.7 8

A1SJ61QBT11Station No. setting switchRUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR. SW M/S PRM TIME LINE E R R O R

MODE

4 56

RUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR.

SW M/S PRM TIME LINE

E R R O R

456

A1SJ61QBT11

Mode setting switchSet the module's operation state.

789

PC interface

RS-232 I/F Peripheral device Positioning High-speed connection counter

23

MODE

NC 1 NC 2 3

Analog

456

78

23

X 1

456

23

X 10

78

78

67

SW OFF 2 3

ON

1 M / L S. M

4 CLR HLD

Remote I/O Master/Local

QJ61BT11N Master module (For Q series)

QnAS master

A1SJ61QBT11 Master module (for QnAS series)

EF

901

012

345

2 3

2 39 0 1EF

ON

901

1 2 3 4 5 6 7 8

2 3

2 3

2 3

34 5

Analog High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embedded Other/ Software Technical Information Support90 1 90 1

901

KSD08

012

CD AB E

CD AB E

901 901

ON

1 2 3 4 5 6 7 8

ON

90 1

1 2 3 4 5 6 7 8

901

KSD08

KSD08

901

901

Product information

Master/Local modules

Master/Local modulesAnS masterMaster/Local Remote I/O Analog456

External dimensionsA1SJ61BT11RUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR. SW M/S PRM TIME LINE SD RD E R R O R

External dimensions85 750.2 (Mounting dimension) 2- 4.5RUN ERR. MST TEST1 TEST2 L RUN L ERR.

87

FX2N-16CCL-M

STATION NO.

MODE

89A

78901 456X 10

BCD 34 5

800.2 (Mounting dimension) 90

RUN ERR. MST TEST1 TEST2

78901 4561 2 3 4 5 6 7 8 X 1

SW OFF ON 1 M / L S. M 2 3 4 CLR HLD 5 1/2 3/4 6 7 8 ISM SFM 1/4 2/3

78901 456

MITSUBISHI

130

B RATE0 156K 1 625K 2 2. 5M 3 4 5M 10M NC

B RATE0 156K 1 625K 2 2.5M 5M 3 4 10M SW OFF ON 1 2 3 4 CLR HLD 5 6 7 8 -

90 1

FX2N-16CCL-M1 NC 2 3 NC 4 5 NC 6 7 NC 8 9

ON

DA

DG

SD RD

SD RD

SLD

Internal current consumption: 0.45A Weight: 0.4kg6.5 93.6 23.9

9

Inside of top cover

(FG) 10

A1SJ61BT11

34.5

Unit: mm

Unit: mm

Applicable CPUCPU module Network module Connectable CPU models A1SCPU, A1SHCPU, A1SJCPU (S3), A1SJHCPU, A1SCPUC24-R2, A2SCPU, A2SHCPU, A2USCPU (S1), A2USHCPU-S1 A1SJ72QLP25, A1SJ72QBR15

Internal current consumption: 5VDC supplied by the module itself. (The 5VDC supply of the PLC is not used.) External current consumption: 150mA (24VDC) Weight: 0.4kg

Applicable CPUCPU module Connectable CPU models FX1N, FX2N, FX3U Series FX1NC, FX2NC, FX3UC Series (FX2NC-CNV-IF required)

Part names and settingsLED indicationThe data link state can be checked by the LED states.

A1SJ61BT11RUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR. SW M/S PRM TIME LINE SD RD E R R O R

A1SJ61BT11RUN ERR. MST S MST LOCAL CPU R / W L RUN L ERR. SW M/S PRM TIME LINE SD RD E R R O R

MODE

Mode setting switchSet the module's operation state. No. Name 0 Online 1 Description Select this when performing the data (Remote network mode) link in the remote network mode. Select this when performing the data Online (Remote I/O network mode) link in the remote I/O network mode.) Offline The data link is disconnected.

789

Part names and settingsSet the module's station No.7890 1

LED indicationThe data link state can be checked by the LED states.23

78901 456

X 1

SW OFF ON 1 M / L S. M

2 3 4 CLR HLD 5 1/2 3/4 6 7 8 ISM SFM 1/4 2/3

SW OFF ON 1 M / L S. M 2 3 4 CLR HLD 5 6 7 8 1/2 1/4 3/4 2/3

Conditions setting switchSwitch Status OFF: Master/Local station ON: Standby master station No. of occupied stations SW5 OFF 1 station No. of SW5 occupied OFF 2 stations* SW6 stations ON 3 stations* ON 4 stations OFF: Intelligent mode SW8 Module mode ON: I/O mode SW1 Station type No. Setting item

456

0 156K 1 625K 2 2. 5M 3 4 5M 10M NC

01 EF 2

34 5

B RATE0 156K 1 625K 2 2.5M 5M 3 4 10M OFF ON CLR HLD -

90 1

DA NC DB NC 4 2

1

ON

(FG) 10

Terminal blockConnect the CC-Link dedicated cables for the data link.

Transmission rate setting switch456

Set the module's transmission rate. No. 0 1 2 3 4 Transmission rate 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps

78 23

A1SJ61BT11

B RATE0 156K 1 625K 2 2. 5M 3 5M 4 10M

29

30

Support

78

9

Terminal blockConnect a twisted-pair cable and power supply for the data link.

Conditions setting switchSet the operation conditionsON

SW OFF ON 1 2 3 4 CLR HLD 5 6 7 8 -

No. Setting SW1 to 3 (Not used) SW4 Input data status of data link error station SW5 to 8 (Not used)

Technical Information

0 1 2 3 4

90 1

23

X 1

456

78

23

Set the module's station No. Master station: 0 Local station: 1 to 64 Standby master station: 1 to 64 * When the mode switch is set to the remote I/O network mode, set the number of connected modules.

X 10

456

78

* Supported by the A1SJ61BT11 hardware version G or later.5

DG NC SLD NC 8 6

7

For other versions, the number of occupied stations is set by SW5 only. OFF: 1 station occupied ON: 4 stations occupied SW6 must be always OFF since its use is not allowed.

Transmission rate setting switchSet the module's transmission rate. No. 0 1 2 3 4 Transmission rate 156kbps 625kbps 2.5Mbps 5Mbps 10MbpsB RATE 156K 625K 2.5M 5M 10M23456

SD RD

Other/ Software

Station No. setting switch

STATION NO.901

3

SW 1 2 3 4 5 6 7 8

BCD

MODE

MODE

01 EF 2

345

23

SW M/S PRM TIME LINE

E R R O R

Embedded

78

B RATE

78

BCD

SW6 OFF ON ON OFF

No. 0 2 3 4 5 6

Setting Online Offline Line test 1 Line test 2 Parameter check test Hardware test

X1

90 1

78

Set the module's operation modeSLD DG

X10

90 1

78901

Mode setting switch

78

X1

90 1

F01

23

23

23

LED name Description ON: The module is normal RUN ON: Communication error for all stations ERR. Flashing: Data link error occurred at some station. MST ON: Set as master station S MST ON: Set as standby master station ON: Set as local station LOCAL CPU R/W ON: Communicating with PLC CPU (FROM/TO) ERROR Lights up when an error occurs L RUN ON: Performing data link L ERR. ON: Communication error (its own station) SD ON: Sending data RD ON: Receiving data

STATION NO.

MODE

23

X 10

23

FX2N-16CCL-M

RUN ERR. MST TEST1 TEST2

STATION NO.

23

L RUN L ERR.

23

POWER

Option

456

456

78901

789

Station No. setting switch

2

STATION NO. X10

LED name Description ON: The module is normal RUN OFF: Watch dog timer error Indicates the status of the communication with ERR. the station specified by the parameter. ON: Communication errors at all stations Flashing: Data link error occurred at some station MST ON: Set as master station TEST1 Indicates the test result. TEST2 Indicates the test result. L RUN ON: Performing data link (its own station) L ERR. ON: Communication error (its own station) Flashing: Some switch setting has been changed with the power on. POWER Turns ON when external power of 24V DC is supplied. SW Some switch setting is erroneous. M/S ON: A master station already exists on the same network. E PRM ON: Parameter setting is erroneous. R TIME ON: Data link monitoring timer has been activated. R (Error at all stations) O R LINE ON: A cable is disconnected, or the transmission path is affected by noise, etc. SD ON: Sending data RD ON: Receiving data

Repeater

F0 1

23

PC interface456 456

RS-232 I/F Peripheral device Positioning High-speed connection counter

DB

SW M/S PRM TIME LINE

E R R O R

BCD

MODE

01 EF 2

345

23

SW E M/S R PRM R TIME O LINE R

Analog

78

DIN rail (35mm) mounting groove

X1

90 1

POWER

78

STATION NO. X10

90 1

23

67

L RUN L ERR.

23

POWER

Remote I/O Master/Local

A1SJ61BT11 Master module (for AnS series)

FX master

FX2N-16CCL-M Master block (for FX series)

2424+ FG

01 EF 2

456

78

23 23 23

ON KSD08

456

SLD DG DA DB

89 67 A

456

1 2 3 4 5 6 7 8

High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embedded Other/ Software Technical Information Support

CD AB E

456

CD AB E

456

2424+ FG

ON KSD08

1 2 3 4 5 6 7 8

ON KSD08

1 2 3 4 5 6 7 8

456

67

89 67 A

89A

DA DB

1 2 3 4 5 6 7 8

901

9 01

1 2 3 4 5 6 7 8

Product information

Remote I/O modules

Remote I/O modulesOverviewFrom a variety of products, you can select the optimum model that matches the connection method and I/O specifications of external devices. Screw terminal block typeScrew T. block

How to read the model name

AJ65 BT1P.

Screw/2-piece terminal block typeP.

2

3

4

5

6 4 I/O points

37

Screw T. block

531 Module typeF: S: V: None: M: Low profile waterproof type Compact type Connector type (compact) Standard type Module type

3 External load connection

2 Cable specificationsHigh-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embedded Other/ Software Technical Information Support

T: Twisted cable (CC-Link dedicated cable)

Spring clamp terminal block typeSpring clamp

Sensor connector type (e-CON)P.

59

Sensor

P.

65

Selection ConsiderationsPush-in connector typePush-in

40-pin FCN connector typeP.

P.

Waterproof connector typeWaterproof

P.

Resistance Output module

Load Output module

Inductance

Load

31

32

Support

Technical Information

Other/ Software

85

Embedded

Option

Repeater

71

40-pin

79

(1) These modules are remote I/O modules dedicated to the CCLink system. Do not connect them to any other data link system such as the MELSECNET/MINI. (2) For the compact type remote I/O modules, 32 points are assigned to one station. When assigning a 16-point or 8-point module, the rest of 16 or 24 points is left empty and is not used. (3) When driving inductive loads with an output module, the maximum switching frequency must be 1 second or more for each of ON and OFF. (4) If a counter or timer containing a DC/DC converter is used as a load for a transistor output module whose maximum load current is 0.1A, an inrush current will flow periodically when the module is ON or in operation. Therefore, selecting a module based on the average current only may cause a failure. To avoid the effect of the inrush current in the case above, connect a resistance or inductance to the load in series, or use an output module of a larger maximum load current.

(5) Since the following additional output modules do not have the short-circuit protection function, provide the function externally: AJ65SBTB1-16T1, AJ65SBTB1-32T1, AJ65SBTB1-8T1, AJ65SBTB2-8T1, AJ65SBTB2-16T1, AJ65SBTC1-32T1, AJ65SBTB1-16DT2, AJ65SBTB1-32DT2, AJ65SBTB1-16DT3, AJ65SBTB1-32DT3, AJ65SBTB32-8DT2, AJ65SBTB32-16DT2, AJ65SBTC4-16DT2, AJ65SBTC1-32DT2, AJ65SBTC1-32DT3, AJ65VBTS2-16T, AJ65VBTS2-32T, AJ65VBTS32-16DT and AJ65VBTS32-32DT

PC interface

RS-232 I/F Peripheral device Positioning High-speed connection counter

A2: 2-wire output type with 8 M12 waterproof connecters 8: 8 points A4: 2- to 4-wire input type with 8 M12 waterproof connecters 16: 16 points A42: 2- to 4-wire input type or 2-wire output type 32: 32 points with 8 M12 waterproof connecters B1: Terminal block, single wire type 5 I/O specifications B1B: Terminal block, single wire type (2 common) A: 100VAC input B2: Terminal block, 2-wire type D: 24VDC input B3: Terminal block, 3-wire type R: Relay output B32: Terminal block, 3-wire type input or 2-wire output type S: Triac output C1: Push-in connector, single wire type T: Transistor output C4: Push-in connector, 4-wire type DT: 24VDC input, transistor output CF1: 40-pin connector (FCN connector), single wire type CU2: Push-in connector, 2-wire type 6 I/O types CU3: Push-in connector, 3-wire type E: Negative common (source) W4: Waterproof connector, 4-wire type input type, source output type L1N: Lead type, single wire type S2: Spring clamp terminal block, 2-wire type S3: Spring clamp terminal block, 3-wire type S32: Spring clamp terminal block, 3-wire type input or 2-wire output type CE2: Sensor connector (e-CON), 2-wire type CE3: Sensor connector (e-CON), 2-wire type CE32: Sensor connector (e-CON), 3-wire output or 2-wire input types

Analog

Remote I/O Master/Local

Master/Local Remote I/O Analog

Product information

Remote I/O modules

Remote I/O modulesModel namesMaster/Local Remote I/O Analog High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embedded Other/ Software Technical Information SupportScrew T. block

For the icons, refer to pages 223 to 224.

Features Type Model AJ65SBTB2N-8A AJ65SBTB2N-16A AJ65SBTB1-8D AJ65SBTB3-8D Input module AJ65SBTB1-16D AJ65SBTB1-16D1 AJ65SBTB3-16D AJ65SBTB1-32D AJ65SBTB1-32D1 AJ65SBTB1-8T AJ65SBTB1-8T1 AJ65SBTB2-8T AJ65SBTB2-8T1 AJ65SBTB1-16T AJ65SBTB1-16T1 AJ65SBTB2-16T Output module AJ65SBTB2-16T1 AJ65SBTB1-32T AJ65SBTB1-32T1 AJ65SBTB1-8TE AJ65SBTB1-16TE AJ65SBTB1B-16TE1 AJ65SBTB1-32TE1 AJ65SBTB2N-8R AJ65SBTB2N-16RAC input

Features Others Page38

Input

Output100VAC

Type Output module

Model AJ65SBTB2N-8S AJ65SBTB2N-16SDC input

InputTriac output

Output0.6A

Others

Page47

8

pts

2

-wire

8 ptsTriac output

2 -wire0.6A

AC input

16 8 8

100VAC

pts

2-wire 1-wire 3-wire 1-wire 1-wire 3-wire 1-wire 1-wireTransistor output

38 39 39

16 pts

2 -wireSink

47Protection

DC inputpts

+COM -COM +COM -COM +COM -COM +COM -COM +COM -COM +COM -COM +COM -COM

24VDC

AJ65SBTB32-8DT AJ65SBTB32-8DT2 AJ65SBTB1-16DT AJ65SBTB1-16DT1 I/O composite module AJ65SBTB1-16DT2 AJ65SBTB1-16DT3 AJ65SBTB32-16DT AJ65SBTB32-16DT2 AJ65SBTB1-32DT AJ65SBTB1-32DT1 AJ65SBTB1-32DT2 AJ65SBTB1-32DT3 AJ65SBTB1-32DTE1 Input module AJ65BTB1-16D AJ65BTB2-16D AJ65BTB1-16T AJ65BTB2-16T AJ65BTB2-16R AJ65BTB1-16DT AJ65BTB2-16DT AJ65BTB2-16DR

4 4 8 8 8 8 8 8

+COM

24VDC

pts

3-wire 3-wire 1-wire 1-wire 1-wire 1-wire 3-wire 3-wire 1-wire 1-wire 1-wire 1-wire 1-wire 1-wire 2-wire

Transistor output

0.5A

4 ptsTransistor output

2 -wire0.5A

48Low leakage

DC inputpts

24VDC

DC inputpts

+COM

24VDC

Sink

4 ptsTransistor output

2 -wire0.5AProtection

48

DC input

pts

pts

8 ptsTransistor output

DC input

16 16 32 32

24VDC

High speed input

pts

40 40

DC inputpts

+COM

24VDC

Sink

0.5A

Protection

8 ptsTransistor output

1 -wire0.5A

High speed input

49Low leakage

DC inputpts

24VDC

DC inputpts

+COM

24VDC

Sink

8 ptsTransistor output

1 -wire0.5A

49

DC inputpts

24VDC

41High speed input

DC inputpts

+COM

24VDC

Sink

8 ptsTransistor output

1 -wire0.5AProtection

High speed input

Low leakage

49 50

DC inputpts

24VDC

DC inputpts

41

+COM

24VDC

Sink

8 ptsTransistor output

2 -wire0.5A

Sink

0.5A

Protection

8 ptsTransistor output

1-wire0.5A

41Low leakage

DC inputpts

+COM

24VDC

Sink

8 ptsTransistor output

2 -wire0.5AProtection

Low leakage

50 51

Sink

Screw T. block

DC input

8 ptsTransistor output

1-wire0.5AProtection

41 42

16 16 16 16 16 16 16

+COM

24VDC

Sink

pts

16 ptsTransistor output

1 -wire0.5AProtection

Sink

DC inputpts

Transistor output

Sink

0.5A

8 ptsTransistor output

2-wire0.5AProtection

Low leakage

42 42

DC inputpts

+COM

24VDC

Transistor output

Sink

0.5A

Protection

16 ptsTransistor output

1 -wire0.5AProtection

51High speed input

Sink

DC inputpts

Transistor output

Sink

0.5A

16 ptsTransistor output

1-wire0.5AProtection

Low leakage

42 43

DC inputpts

+COM

24VDC

Transistor output

Sink

0.5A

16 pts

1 -wire

52 54 54

Sink

DC inputpts

Transistor output

Sink

0.5A

Screw/2-piece terminal block type

16 ptsTransistor output

2-wire0.5AProtection

Low leakage

43 43

DC inputpts

+COM -COM

24VDC

Sink

Transistor output

Sink

0.5A

32 ptsTransistor output

1-wire0.1AProtection

Low leakage

43 44

Transistor output

Sink

0.5A

16 ptsRelay output

2 -wire2.0A

55 56 57 58 58

I/O composite module

Transistor output

0.1ASource

Protection

16 ptsTransistor output

1-wire0.1A

44 45 45 46 46

DC input

8 8 8

+COM

24VDC

pts

1-wire 2-wire 2-wire

Transistor output

Sink

0.5A

8 ptsTransistor output

1 -wire0.5A

DC inputpts

Transistor output

0.1ASource

DC inputpts

32 ptsRelay output

1-wire2A

+COM -COM

24VDC

Relay output

2.0A

8 pts

2 -wire

Relay output

2A

16 pts

2-wire

33

34

Support

8 pts

2-wire

Technical Information

16 pts

Source

1-wire

+COM

24VDC

Sink

8 pts

2 -wire

Other/ Software

8 pts

Source

1-wire

16 pts

2 -wire

Embedded

32 pts

Output module

1-wire

Transistor output

Sink

0.5A

16 pts

1 -wire

55

Option

16 pts

2-wire

+COM -COM

24VDC

Repeater

16 pts

1-wire

+COM

24VDC

Sink

16 pts

1 -wire

51

PC interface

8 pts

2-wire

+COM

24VDC DC24V

Sink

16 pts

1 -wire

High speed input

51

RS-232 I/F Peripheral device Positioning High-speed connection counter

16

24VDC

40

DC input

+COM

24VDC

Sink

1 -wire

49

Analog

Remote I/O Master/Local

Product information

Remote I/O modules

Remote I/O modulesModel namesMaster/Local Remote I/O Analog High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface Repeater Option Embedded Other/ Software Technical Information SupportPush-in

For the icons, refer to pages 223 to 224.

Features Type I/O composite Output module Input module module ModelAJ65VBTS3-16DDC input

Features Others Page60Push-in

Input

Output24VDC

Type I/O composite module

ModelDC input

Input

OutputTransistor output

Others0.5AProtection

Page77Low leakage

16 32

+COM

pts

3 -wire24VDC

AJ65SBTC4-16DT

8 8

+COM

24VDC

pts

4 -wire24VDC

Sink

8 ptsTransistor output

4 -wire0.5A

AJ65VBTS3-32D

DC inputpts

+COM

3 -wireTransistor output

61Sink

AJ65SBTC4-16DT2

DC inputpts

+COM

4 -wire24VDC

Sink

8 ptsTransistor output

4 -wire0.1AProtection

77

AJ65VBTS2-32TDC input+COM

Transistor output

Sink

0.5A

32 pts24VDC

2 -wire0.5A

62Push-in

AJ65SBTC1-32DT1

DC input

16 16 16 32

+COM

24VDC

pts

1 -wire24VDC

Transistor output

Sink

0.1A

Protection

16 ptsTransistor output

1 -wire0.1A

High speed input

78Low leakage

AJ65VBTS32-16DT

8

pts

3 -wire24VDC

Transistor output

Sink

8 ptsTransistor output

2 -wire0.5A

63

AJ65SBTC1-32DT2

DC inputpts

+COM

1 -wire24VDC

Sink

16 ptsTransistor output

1 -wire0.1A

78

DC input

AJ65VBTS32-32DT

16 8

+COM

pts

3 -wire24VDC

Sink

16 pts

2 -wireVertical

64

AJ65SBTC1-32DT3

DC inputpts

+COM

1 -wire24VDC

Sink

16 pts

1 -wire

High speed input

Low leakage

78

DC input

AJ65VBTCE3-8D

+COM

Output Input Output module Input module I/O composite Output module Input module I/O composite module module module module

Input module

pts

3 -wire24VDCVertical

66

AJ65SBTCF1-32D

DC inputpts

+COM -COM

1 -wireTransistor output

81Sink

DC input

AJ65VBTCE3-16D

16 32

+COM

pts

3 -wire24VDCVertical

6740-pin

AJ65SBTCF1-32TDC input+COM -COM +COM -COM +COM

0.1A

Protection

32 pts24VDC

1 -wire0.1AProtection

81

DC input

AJ65VBTCE3-32D

+COM

pts

3 -wireTransistor output

67Sink

AJ65SBTCF1-32DT

16 16 16 16

pts

1 -wire24VDC

Transistor output

Sink

16 ptsTransistor output

1 -wire0.1AProtectionVertical installation

82

Sensor

I/O composite Output module module

0.1A

Protection

Vertical

AJ65VBTCE2-8T

8 ptsTransistor output

1 -wire0.1AProtectionVertical

68

AJ65VBTCF1-32DT1

DC inputpts

1 -wire24VDC

Sink

16 ptsto24VDC

1 -wire

83

AJ65VBTCE2-16TDC input+COM

Sink

AJ65VBTCE32-16DT

24VDC

8

pts

3 -wire24VDC

Transistor output

Sink

0.1A

Protection

Vertical

8 ptsTransistor output

2 -wire0.1AProtectionVertical

69

AJ65FBTA4-16DE

DC inputpts

24VDC-COM

2 -wire

to

24VDC

4 -wireTransistor output

87Sink

DC input

AJ65VBTCE32-32DT

Waterproof Waterproof aterproofVertical

AJ65VBTCU3-8D1

DC input

8

+COM

24VDC

pts

3 -wire24VDCVertical

73

AJ65FBTA2-16TEDC input+COM

Transistor output

1.0ASource Sink

Protection

16 pts24VDC

2 -wire0.5AProtection

88

DC input

pts

pts

Input module

DC input

AJ65SBTC4-16DN

16 16 32 32

+COM

24VDC

pts

4 -wire24VDC

74

DC input

AJ65FBTA42-16DTE

24V DC-COM +COM

8

pts

2 -wireInput V.

to

24V DC

4 -wire

Transistor output

1.0ASource

Protection

8 pts

2 -wire

89

DC input

pts

-COM +COM -COM +COM -COM

pts

24VDC+COMInput V.

AJ65SBTC1-32D

DC inputpts

24VDC

1 -wire24VDC

75High speed input

AJ65MBTL1N-32D

DC input

32

pts

24VDCTransistor output

192SinkInput load currentProtection

AJ65SBTC1-32D1

pts

1 -wireTransistor output

75

AJ65MBTL1N-16T

16 ptsTransistor output

0.1ASinkInput load currentProtection

193

AJ65VBTCU2-8T

Sink

0.1A

Protection

Vertical

8 ptsTransistor output

2 -wire0.1AProtectionVertical

75

Refer to page 191 and later pages.

AJ65MBTL1N-32TDC input+COMInput V.

32 pts

0.1ASinkInput load currentProtection

193

Output module

AJ65VBTCU2-16T

Sink

16 ptsTransistor output

2 -wire0.1AProtection

75

AJ65MBTL1N-16DT

8

pts

24VDC

Transistor output

8 pts

0.1A

194

AJ65SBTC1-32T

Sink

32 ptsTransistor output

1 -wire0.1A

76Low leakage

AJ65SBTC1-32T1

Sink

32 pts

1 -wire

76

35

36

Support

Technical Information

I/O composite module

Other/ Software

DC input

Embeded

Embedded

AJ65SBTC4-16DE

4 -wire

74

AJ65MBTL1N-16D

DC input

16

192

Option

AJ65VBTCU3-16D1

16

+COM

3 -wire

73

AJ65FBTA42-16DT

8

2 -wire

to

24VDC

4 -wire

Transistor output

8 pts

2 -wire

89

Repeater

16

+COM

pts

3 -wire

Sink

16 pts

2 -wire

70

AJ65FBTA2-16T

0.5A

Protection

16 pts

2 -wire

88

PC interface

16 pts

2 -wire

68

DC input

AJ65FBTA4-16D

pts

2 -wire

4 -wire

87

RS-232 I/F Peripheral device Positioning High-speed connection counter

Analog

Spring clamp

I/O composite module

AJ65VBTS2-16T

0.5A

16 pts

2 -wire

61

AJ65SBTC1-32DT

DC input

16

+COM

pts

1 -wire

Sink

16 pts

1 -wire

78

Remote I/O Master/Local

Product information

Remote I/O modules

Remote I/O modulesInput moduleAC input 100VACScrew T. block

AJ65SBTB2N-8AScrew T. blockMaster/Local Remote I/O Analog High-speed Positioning Peripheral device RS-232 I/F counter connection PC interface RepeaterLED indicationLED name Description PW Turns ON when the remote I/O module is powered ON. L RUN Turns ON when normal data are received from the master station and goes OFF when the timeout is reached. L ERR ON: Communication error Flashing at regular intervals: The station No. and/or transmission rate switch setting has been changed while the power is on. Flashing irregularly: The terminating resistor setting is incorrect, or the module and CC-Link dedicated cables are being affected by noise. OFF: Communication is normal. X0 to 1F Indicates the input ON/OFF status. Turns ON and OFF when the input is ON or OFF respectively.

8

pts

2

-wire

OverviewScrew terminal block type

FeaturesThe use of self-up screws reduces wiring works. The round crimp terminal can be directly connected with the self-up screw by simply unfastening the terminal block screw. The charging area is covered by a finger protector on the upper part of the terminal block so that people cannot touch it. Direct mounting on machine in 6 directions.Detailed specificationsInput specifications Number of input points Isolation method Rated input voltage/Frequency Rated input current Operating voltage range Input derating Description 8 points Photocoupler 100 to 120VAC 50/60Hz Approx. 7mA (100VAC 60Hz) 85 to 132VAC ((50/60Hz 3Hz (within 5% of distortion rate)) 100% simultaneous ON (at 110VAC) 60% simultaneous ON (at 132VAC) Max. 200mA within 1ms (at 132VAC) Inrush current 80VAC/3.5mA or higher ON voltage/ON current OFF voltage/OFF current 30VAC/1.7mA or lower Input resistance Approx. 15k (60Hz), Approx.18k (50Hz) Response OFF ON 20ms or less (at 100VAC 60Hz) time ON OFF 20ms or less (at 100VAC 60Hz) Wiring method for common 8 points/common (Terminal block 2-wire type) No. of stations occupied Assignment of 32 points/station (8 points used) I/O module Voltage 20.4 to 26.4VDC (ripple ratio: within 5%) power supply Current 35mA or lower (at 24VDC, with all points ON) Noise immunity Fast transient/burst noise created by a noise simulator of 1500Vp-p, noise width 1s and 25 to 60Hz frequency (IEC61000-4-4): 1kV Withstand voltage 1780VAC rms/3 cycles across AC external terminals and ground (altitude 2000m) 500VAC for 1 minute across DC external terminals and ground Insulation resistance 10M or more by 500VDC insulation resistance tester across AC external terminals and ground 10M or more by 500VDC insulation resistance tester across DC external terminals and ground Weight (kg) 0.2

1 2 3 4 5 6 7 Module power supply

DA DB DG SLD +24V FG 24G

Insulation

DC DC

100VAC

X0

X1

X2

X3

X4

X5

X6

X7

COMA

COMB COMB COMB COMB COMB COMB COMB COMB COMB

* The actual modules may slightly differ in shapes from the photos shown.

Part names and functions

Input module

AC input

100VAC

Screw T. block

External device connection diagramStation No. setting switchSet the 10s place using 10, 20 and/or 40 of STATION NO. Set the 1s place using 1, 2, 4 and/or 8 of STATION NO. Make sure that the setting is within the range of 1 to 64.1 2 3 4 5 6 7 DA DB DG SLD +24V FG 24G X0 COM B X1 COM B X2 COM B X3 COM B X4 COM B X5 COM B X6 COM B X7 COM B X8 COM B X9 COM B XA COM B XB COM B XC COM B XD COM B XE COM B XF COM B COM A COM B R

External dimensions & terminal layout

Unit: mm

DC/DC

Module power supply

Transmission rate setting switchSetting value

16.5

X0 1 2 3 4 5 6 7

AJ65SBTB2N-16AON

50

ON

DA DG +24V DB SLD

24G (FG)

X6 XE X0 X1 X2 X3 X4 X5 X7 X8 X9 XA XB XC XD XF COMA COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB COMB

AJ65SBTB1-8DDA DB DG +24V SLD 24G (FG) X0 X1 X2 X3 X4 X5 X6 COM X7 COM

7.9

7.5

STATION NO. B RATE 40 20 10 8 4 2 1 4 2 1

0 1 2 3 4

Transmission rate 156kbps 625kbps 2.5Mbps 5Mbps 10Mbps

89

100VAC

Terminal block

DIN rail mounting hookThis hook is used to mount the module on the DIN rail.

37

38

Support

Technical Information

Other/ Software

X0

COM X1 X2 X3 X4 X5 X6 X7 X8 X9 XA XB XC XD XE XF A COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM COM B B B B B B B B B B B B B B B B B

Embedded

Input specifications Number of input points Isolation method Rated input voltage/Frequency Rated input current Operating voltage range Input derating

Description 16 points Photocoupler 100 to 120VAC 50/60Hz Approx. 7mA (100VAC 60Hz) 85 to 132VAC ((50/60Hz 3Hz (within 5% of distortion rate)) 100% simultaneous ON (at 110VAC) 60% simultaneous ON (at 132VAC) Max. 200mA within 1ms (at 132VAC) Inrush current 80VAC/5mA or higher ON voltage/ON current OFF voltage/OFF current 30VAC/1.7mA or lower Input resistance Approx. 15k (60Hz), Approx.18k (50Hz) Response OFF ON 20ms or less (at 100VAC 60Hz) time ON OFF 20ms or less (at 100VAC 60Hz) Wiring method for common 16 points/common (Terminal block 2-wire type) No. of stations occupied Assignment of 32 points/station (16 po