CC-Link + Industrial Ethernet =The Field Network Revolution BeginsCC-L ink IE Field Network
Debut!
2010 Sep
.
To use the products given in this publication properly, always read the relevant manuals before use.The products have been manufactured as general-purpose parts for general industries, and have not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.The products have been manufactured under strict quality control. However, when installing the products where major accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system.
This publication explains the typical features and functions of the products herein and does not provide restrictions and other information related to usage and module combinations. Before using the products, always read the product user manuals.Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; opportunity loss or lost profits caused by faults in Mitsubishi Electric products; damage, secondary damage, or accident compensation, whether foreseeable or not, caused by special factors; damage to products other than Mitsubishi Electric products; and to other duties.
Precautions before use Ethernet-based Open NetworkCC-Link IE Product Catalog
Ethernet-based Open NetworkCC-Link IE Product Catalog
L(NA)08111E-D 1102(MDOC)New publication as of Feb. 2011
Specifications subject to change without notice.
1 2
A major innovation in industrial networks providing reliable, flexible, and seamless communication
CC-Link + Industrial Ethernet =
Today there is an increasing demand from production facilities for high speed control, effective management of data, flexible wiring, easy parameter settings, and predictive maintenance. Mitsubishi Electric is responding to these needs with the introduction of the CC-Link IE Field Network. In combination with a CC-Link IE Controller Network, the field network provides seamless gigabit performance down to the device level to optimize the production sites of our customers.
1Gbps 32,768bits16Kwords
CopperSTP
cableEthernet-
based
Seamlessnetworking
Ethernet-based
CC-Link IE Field builds on proven Ethernet technology to enable real time control and gigabit speed information transfer from the shop floor to the top floor
High Speed, Economical, Flexible Network
Designed for high reliability, CC-Link IE is a controller-to-controller network using a 1Gbps dual loop fiber optic connection. Up to 128K words of link registers can be shared among controllers providing ample bandwidth for ever increasing amounts of recipe and traceability data.
High Speed, Large Capacity, Reliable Network
The network is designed to simultaneously handle distributed control, I/O control, and motion control*1. The network wiring layout is highly flexible to best fit the needs of the application. Choose from line, star, line and star mixed, or ring topology. *1) Planned
Communicationspeed
1Gbps
Communicationspeed
Ringtopology
Linetopology
Networkdiagnosis
at-a-glance
Networkdiagnosis
at-a-glance
Easy toconfigure
parameters
Seamlessnetworking
Easy toconfigure
parameters
Multi-modeoptical fiber
cable
Maximum linkrelays
Maximum linkregisters
32,768bits128Kwords
Maximum linkrelays
Maximum linkregisters
Dualopticalloop
Externalpowersupply
Ringtopology
Startopology
3 4
Info
rmat
ion
syst
emP
rod
ucti
on
site
Seamlessdata
communication
I N D E X
P.39
P.5
P.53List of compatible products
Seamless communication between upper-level information systems and lower-level field systems!Choose the optimal network to meet your needs
Ethernet-based open network
LAN (Ethernet)
PLC
MES (manufacturing execution system)
HMI PC Interface board
Seamlessdata
communication
Computerlevel network
Controllerlevel network
Devicelevel network
MES
Safety remote I/O
RemoteI/O
Emergency stop Warning light
SERVO SYSTEM CONTROLLER NETWORK
Servomotor
PC
Vision sensor
HMI
PC
InverterRemoteI/O
CC-Link CC-Link/LT bridge
PLC (master)
PLC(local)
Ethernetadapter
PLC(local)
Remote I/O(remote)
Remote I/O(remote)
PC Interface board[NEW]
Valve control
General I/OAnalog I/O Sensor connection
PLC Safety PLCIndustrial switching hub
SmallSmall
Large
High
Low
Datacapacity
Real timeperformance
This "core" network is intended for high-speed, large bandwidth controller level distributed control. Reliability is ensured through dual fiber optic loop connections and extensive RAS functions.
This new industrial Ethernet field network enables intelligent manufacturing systems to perform high speed I/O control and distributed control simultaneously. Wiring is done easily thanks to standard Ethernet cables and flexible topology.
Gigabit Ethernet
Gigabit Ethernet
Released in 1996, CC-Link has become a global leader in open fieldbus networks. CC-Link Safety achieves the same outstanding performance of CC-Link while meeting strict safety requirements. CC-Link/LT is a cost saving network for small I/O applications.
This is a Mitsubishi original servo system network designed for reliability. It utilizes an optical network for smooth, fast-response, and high-accuracy operation under all circumstances.
SERVO SYSTEM CONTROLLER NETWORK
PLC engineering softwareMELSOFT GX Works2
SERVO SYSTEM CONTROLLER NETWORK
Ethernet
Information communication
Distributed control
I/O control Motion control
For System Designers
For Maintenance Technicians
High-speed communication reduces takt time and stabilizes the control interval for higher performance! ...P.7■Shorten cycle times■ Increase the number of control applications and associated data without
changing the takt time■Achieve a stable communication period for better control stability
Simplified network settings make configuring the network easy! ................................................................P.9■Configure all network parameters from a central location
Ease of connectivity means other stations can be accessed from anywhere, even across multiple networks! .............P.11■Observe the entire factory from a single office computer
Cut costs by using commercially available Ethernet equipment!..........................................................P.12■Regardless of geographical location, network cables
and equipment are easy to purchase■Network cables and equipment are comparatively inexpensive
Flexibility allows easy addition of nodes and changes to the network layout! ..................................P.8■Connections can easily be moved to fit a rearrangement of production lines■The arrangement of equipment is highly flexible
Engineering tools make wiring problems and errors easy to diagnose!............................................P.10■The network can automatically detect problems and suggest solutions■Minimize downtime with the ability to respond quickly to problems
Ease of connectivity means other stations can be accessed from anywhere, even across multiple networks! .............P.11■Access any point on the network from the nearest station or hub■Perform maintenance duties without having to physically go to each machine
Cut costs by using commercially available Ethernet equipment!..........................................................P.12■Regardless of geographical location, network cables
and equipment are easy to purchase■Network cables and equipment are comparatively inexpensive
This versatile field network integrates
distributed control, I/O control, and
motion control *1.
Its flexible wiring design allows for
star, line, star and line mixed, or ring
topology to ensure the network can
meet the needs of any production line
or equipment layout.*1) Planned
CASE 1
CASE 5
CASE 3
CASE 6
CASE 5
CASE 2
CASE 4
CASE 6
5 6
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
7
Benefits of CC-Link IE Field Network
8
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
High-speed communication reduces takt timeand stabilizes the control interval for higher performance!
High-speed 1 Gbps communication
High-speed communication reduces takt time
The unprecedented data transfer speed provided by CC-Link IE Field increases the effectiveness of controller-to-controller and controller-to-field device communications, thus reducing takt time. It is now simple to establish high-speed I/O control and powerful distributed control systems.
The ability to transfer large volumes of data enables high performance field devices to reach their full potential. With the ability to transfer large amounts of traceability data, systems capable of highly-detailed diagnostics can be constructed.
The total bandwidth is divided between deterministic (cyclic) communication and transient (message) communication. The cyclic communication band, intended for I/O control, is fixed and will not suffer from degraded performance even when large volumes of traceability and diagnostic data are transferred via transient communication.
For example... For example...
Cyclic communication is stable and reliable
Improved quality of communication is achieved using a stable control period
Flexible network topology
Add nodes or change the network layout entirelyThe system is highly flexible!
Various network topologies may be used including star, line, star and line combination. This flexibility allows additional equipment to be simply connected to any available port, with little concern for restrictions.Ring topology* can be used also.
Flexibility allows easy addition of nodesand changes to the network layout!
CASE 1
1Gbps
Q series (local)
Q series (master)
L series (remote)
L series (remote)
L series (remote)
Combine L series intelligent function modules and I/O to build remote stations that best fit the application.
1 Gbps(broadband)
Stabletiming
Cyclic communication band (for I/O control)
Transient (message) communication band (for traceability and other data)
System designer
I want to reduce the takt time.
I'm going to increase the number of control applications
and all associated data, but want to keep the takt time
unchanged.
I want the communication period to be stable for better control stability.
Number of data sets
Amount of
information
Communicationspeed
Load
High-speedcommunication
Largecapacity
Communicationstability
I want more flexibility when it comes to the arrangement of equipment.
Sometimes I need to change the layout of our production line.
Maintenance technician
Existing system
Easily integrate new equipment withthe existing system
New!
* Star or line topology cannot be mixed with ring.
Star topology
Line topology
Ring topology
Add new equipment simply by connectingto any available port. The time it takes to
connect and configure devices is minimized!
CASE 2
makes it possible... makes it possible...
1Gbps
Communicationspeed
16Kwords
Maximum linkregisters Star
topologyLine
topologyRing
topology
9
Benefits of CC-Link IE Field Network
10
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Simplified network settings make configuring the network easy!
Engineering tools make wiring problemsand errors easy to diagnose!
Easy diagnosis functions
Perform diagnostics and troubleshoot effectively regardless of experienceEasy to configure settings
Just configure the master station to begin communicationsIt's that easy!
GX Works2* enables you to identify network errors at a glance. You can quickly identify the cause of a problem and implement the suggested remedy to minimize down time.
The network diagnostics tool automatically creates a graphical representation of the network. Using this diagram, cable problems and PLC errors are clearly visible allowing for fast response. Additionally, the condition of any remote station on the network can be monitored by directly accessing it from the same screen.
Network parameters are configured using the engineering tool, GX Works2*. Only the master station needs to be configured, thereby greatly simplifying the network setup. Updating the system configuration is a breeze.
For example... For example...
CASE 3 CASE 4
I want to configure all of the network parameters fromone place.
System designer
Getting the network up and running is complicated and time consuming...
Do I really have to configure every single PLC?How tiresome...
Station #3Station #2Station #1
Setting 1 Setting 2 Setting 3I need to be able toreact faster if there
is a problem.
It would be nice if thesystem could tell mewhat is wrong with it. Where is the
problem...
ErrorOK
OK
Maintenance technician
Easy toconfigure
parameters
Networkdiagnosis
at-a-glance
Cable disconnected!I was able to immediatelyidentify the cause of the problem.
How convenient!
GX Works2
* Not compatible with GX Developer
The network conditionis automatically
examined bythe diagnostic tool
* Not compatible with GX Developer
Master station parameters
All of the network settings arein one place. It's so simple!
Settings
Transferred
Master stationStation #1 Station #2
Station #3
Transferred
Master station settings are all that is required.
Transferred
Transferred
makes it possible... makes it possible...
11
Benefits of CC-Link IE Field Network
12
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Cut costs by using commercially available Ethernet equipment!
Ethernet-based network
Built on global standards
CC-Link IE Field has been designed to make use of commercially available Ethernet components including cables and hubs. Thanks to the common availability of these components, significant cost savings over alternative networks can be achieved.*1
Using the Ethernet adapter unit , Seamless Message Protocol (SLMP)*2 compatible Ethernet devices can be connected to the CC-Link IE Field network. A wide range of devices can be connected such as vision sensors and RFID controllers.
Ease of connectivity means other stations can be accessed from anywhere, even across multiple networks!
Seamless communication
Remotely collect information and perform maintenance operations from anywhere!
When joined together, different CC-Link networks operate seamlessly as one network so there is no need to pay attention to the network hierarchy. Once communication is established, data can be collected from field devices and maintenance duties can be performed. Everything from the field equipment to the upper level information system is accessible from any point on the network.
For example... For example...
*1) Use the cables recommended by the CC-Link Partner Association for the CC-Link IE Field Network.
CASE 6
PC
Ethernet adapter
100M/1Gbps
1Gbps
Master station
RFID controller
Barcode reader
Vision sensor
Label printer
Ethernet devices compatible with Seamless Message Protocol (SLMP)*2
*2) Seamless message protocol (SLMP) is an integral part of CC-Link IE Field that supports transient communications.
System designer
I want a network thatallows me to observe the
entire factory from a personal computer in my office.
I want to perform maintenance duties without having to go to the
machine every time.
I want to access other equipment from the
nearest station.
Maintenance technician
I want to use common components and general-purpose equipment...
I want to cut costs...
System designer
I want less expensive equipment and cables.
I want to be able to easily purchase network cables and equipment regardless of my
geographical location.
Maintenance technician
Ethernet cable
Ethernet HUB Inline coupler
Ethernet connector
MELSECNET/H
Info
rmat
ion
netw
ork
Con
trol
ler
netw
ork
Fiel
d ne
twor
kW
ire-s
avin
g ne
twor
k
Seamless communication!Ethernet
GX Works2
OfficeI can work more efficiently with the ability to perform
maintenance duties and access settings
from anywhere on site!
I can batch monitor and change settings from the
comfort of my office!
CASE 5
Seamlessnetworking
Ethernet-based
makes it possible... makes it possible...
13 14
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Network examples
Semiconductor production system Automotive production process
Seamless communication
Flexible wiring
CC-Link integration
Quickly create high speed connections between controllers in each chamber
The entire system can easily be monitored and controlled from a central location thanks to seamless communication.
Many different kinds of CC-Link compatible products can be used.
Choose a network topology that best matches the arrangement of devices in the system.
CC-Link IE Field remote I/O stations allow L series I/O modules to be used without the need for CPU units.
Chamber replacement and
maintenance are easy with Ethernet wiring.
Chamber control boxPower control box
Inverter Valve control Remote I/O Servo Analog I/O
HUB
Main controller (master station)
RF power supply RF power supply
It is easy to collect detailed information about each process for
traceability purposes.
Star and line topologies can be mixed.
Easily connect additional equipment.
The entire system can easily be monitored and controlled from a central location thanks to seamless communication.
The wiring design is flexible to match the network structure and devices.
Power trainmachining
Power trainassembly
Pressing Welding Coating Final assembly
Star topology
Line topology
Q series(master)
HUB
The entire system is operated and monitored from one place.
Incorporating CC-Link allows a wide variety of devices to be connected.
Seamless communication
Flexible wiring
Distributed control
The entire system is operated and monitored from one place.
With the ability to share large amounts of data at high speed, controllers can work together in unison.
Main control box
Star and line topologies can be mixed. Star and line topologies can be mixed.
15 16
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
CC-Link IE Field Network Master/Local Module for MELSEC-Q Series
QJ71GF11-T2
CC-Link IE Field Network Head Module for MELSEC-L Series
LJ72GF15-T2CC-Link IE Field Network Ethernet adapter module
NZ2GF-ETB*1
Industrial switching hub
NZ2EHG-T8 / NZ2EHF-T8
Features
¡Can operate as either a master or local station. Perfect for managing remote I/O control and distributed control.
¡Devices from other stations can easily be accessed through transient communication using dedicated instructions.
¡Function blocks for transient communication are available to further simplify messaging.¡The network can ensure 32bit data integrity using the station-based block data assurance
function. (This ensures that pairs of word data are updated together during link refresh.)
Features
¡Using the head module, remote stations can be created from MELSEC-L Series I/O modules and intelligent function modules. Money can be saved on spare parts because the modules are the same as used with the CPU units.*1
¡Create remote I/O stations that just fit the application while maintaining the flexibility to grow. Save on wiring costs by condensing remote I/O to a single station.
¡Access to other stations by way of remote I/O stations is possible, thus increasing the effectiveness of GX Works2.
¡Troubleshooting, even after a power failure, is simple. Error information from remote I/O stations is automatically preserved by the master station.
Features
¡Using Seamless Message Protocol (SLMP), a variety of Ethernet devices such as vision sensors and RFID controllers can be connected to the CC-Link IE Field network.
¡Use a web browser to set station numbers, Ethernet options, and view error history.
¡This Ethernet adapter module is compatible with transmission rates of 100 Mbps and 1 Gbps.
Compatible PLC CPU ............................................................................................................. Universal model QCPU*1
*1) Q00UJCPU, Q00UCPU, Q01UCPU, Q02UCPU, Q03UDECPU, Q03UDCPU, Q04UDEHCPU, Q04UDHCPU, Q06UDEHCPU, Q06UDHCPU, Q10UDEHCPU, Q10UDHCPU, Q13UDEHCPU, Q13UDHCPU, Q20UDEHCPU, Q20UDHCPU, Q26UDEHCPU, Q26UDHCPU, Q50UDEHCPU, Q100UDEHCPU (The first five digits of the serial number are 12012 or larger.)
Powered by CONTEC
Features
¡NZ2EHG-T8 is compatible with transmission rates of 10 Mbps, 100 Mbps, and 1 Gbps.
¡NZ2EHF-T8*1 is compatible with transmission rates of 10 Mbps and 100 Mbps.
¡These switching hubs comply with IEEE802.3ab (1000 BASE-T), IEEE802.3u (100 BASE-TX), IEEE802.3 (10 BASE-T) standards.
¡AutoMDI/MDI-X and auto-negotiation are available.¡The automatic power adjustment function can reduce power consumption by
up to 80 percent.*2 ¡These hubs do not use cooling fans, and yet a wide ambient-temperature
operating range is permissible (0 to 50°C).¡Quick detach mechanism allows easy DIN rail attachment and detachment.
Product lineup
*1) For details of applicable modules, refer to the following pages (page 17 to 34).
*1) This model may not be connected directly to the CC-Link IE Field Network (1 Gbps). An Ethernet adapter module NZ2GF-ETB is required. For direct use with the CC-Link IE Field Network, please use NZ2EHG-T8.
*2) For comparison, power consumption was measured when all 8 ports were used and when none of them were used. This function is only available for NZ2EHG-T8. The NZ2EHG-T8 and NZ2EHF-T8 have a rated input supply voltage of 12 to 24 VDC. This series was developed and is produced with Contec Co. Ltd. Please note that the specifications and guarantee conditions of these products are different from those of MELSEC products.
*1) GX Works2 (Version 1.40S or later) is required to make settings and to conduct diagnosis of stations using extended mode.
1 Gbps100 Mbps
NEW
NEW
CC-Link IE Field Network PC Interface Board
Q81BD-J71GF11-T2
Features
¡Connect PC based control systems directly to the CC-Link IE Field Network.
¡Can operate as a master or local station.¡PCI Express connection.
PC board system requirements
Item Q81BD-J71GF11-T2
PCindustrial computer
Windows® compatible PC
CPU Intel® Celeron® 2.8GHz or higher
Required memoryWindows® 2000, Windows® XP : 256MB or more
Windows Vista®, Windows Server® : 512MB or moreWindows® 7 : 1GB or more
Slot PCI Express slot - x1, x4, x8 and x16 (low profile, standard / half height)
PCI Express bus PCI Express Rev.1.1 (DC3.3V, bandwidth 250 MB/ s, bus clock frequency 100MHz)
Operating system(English Version)*1*2
Microsoft® Windows® 7 Home Premium Microsoft® Windows® 7 Professional Microsoft® Windows® 7 Ultimate Microsoft® Windows® 7 Enterprise Microsoft® Windows Vista® Home Basic (Service Pack 2 or later)Microsoft® Windows Vista® Home Premium (Service Pack 2 or later)Microsoft® Windows Vista® Business (Service Pack 2 or later)
Microsoft® Windows Vista® Ultimate (Service Pack 2 or later)Microsoft® Windows Vista® Enterprise (Service Pack 2 or later)Microsoft® Windows Server® 2003 R2 (Service Pack 2 or later)Microsoft® Windows Server® 2008 (Service Pack 2 or later)Microsoft® Windows® XP Home Edition (Service Pack 3 or later)Microsoft® Windows® XP Professional (Service Pack 3 or later)
Display Resolution: 1024 x 768 or better
Hard disk space 1GB or more
Removable media drive CD-ROM compatible
Programming language(English Version)*1
Microsoft® Visual Basic® .NET 2003Microsoft® Visual Studio 2005 Visual Basic®
Microsoft® Visual Studio 2008 Visual Basic®
Microsoft® Visual Studio .NET 2003 Visual C++®
Microsoft® Visual Studio 2005 Visual C++®Microsoft® Visual Studio 2008 Visual C++®
*1) User programs created in the English environment work only in the English environment. *2) 64-bit version is not supported.
Available soon
Mix and match up to 10 L series I/O modules and intelligent function modules per station.
17 18
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
■ LX40C6DC input
■ LX41C4DC input
■ LY10R2Contact output
■ LY41NT1PTransistor output
■ LX42C4DC input
■ LY42NT1PTransistor output
Response time
1 to 70ms
Response time
1 to 70ms
Response time
1 to 70ms
Rated switching current
2A/point
Maximum load current
0.1A/point
Maximum load current
0.1A/point
Sink type
Sink type
Rated input voltage
24VDC
Rated input voltage
24VDC
Rated input voltage
24VDC
Contact output
Transistor output
Transistor output
Number of inputs
16 points
Number of inputs
32 points
Number of inputs
64 points
Number of outputs
16 points
Number of outputs
32 points
Number of outputs
64 points
External connections
18-point terminal block
External connections
40-pin
connector
External connections
40-pin
connector ×2
Response time
10ms or less
Response time
0.5ms or less
Response time
0.5ms or less
Positive/Negativecommon
Positive/Negativecommon
Positive/Negativecommon
Maximum switching load
264VAC/125VDC
Rated load voltage
12 to 24VDC
Rated load voltage
12 to 24VDC
External connections
18-point
terminal block
External connections
40-pin
connector
External connections
40-pin
connector ×2
Product lineup (For CC-Link IE Field Network Head Module)
Input Modules Output Modules
•Allmodelsarecapableofusingbothpositiveornegative common connections; separate modules are not necessary.
•Matchtheresponsespeedtotheconnecteddevices. Choose from 1, 5, 10, 20, or 70ms.
Positive or negative common Adjustable sensing speed
■ Input module specifications[DC input module]
Item LX40C6 LX41C4 LX42C4
Number of input points 16 points 32 points 64 points
Rated input voltage 24VDC (+20%/-15%, ripple ratio within 5%)
Rated input current 6.0mA TYP. (at 24VDC) 4.0mA TYP. (at 24VDC)
ON voltage/ON current 15V or higher/4mA or higher 19V or higher/3mA or higher
OFF voltage/OFF current 8V or lower/2mA or lower 9V or lower/1.7mA or lower
Input impedance 3.8kΩ 5.7kΩ
Response timeOFF to ON 1ms/5ms/10ms/20ms/70ms or less
Initial setting is 10ms.ON to OFF
Common terminal arrangement 16 points/common 32 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O allocation: input 16 points) 32 points (I/O assignment: 32 input points) 64 points (I/O allocation: input 64 points)
External connections 18-point screw terminal block 40-pin connector 40-pin connector ×2
5VDC internal current consumption 90mA (TYP. all points ON) 100mA (TYP. all points ON) 120mA (TYP. all points ON)
Weight 0.15kg 0.11kg 0.12kg
■ LY41PT1PTransistor output
Response time
0.5ms or less
Maximum load current
0.1A/pointRated load voltage
12 to 24VDCNumber of outputs
32 pointsTransistor
output
External connections
40-pin
connector Source type Protection
Function
■ LY42PT1PTransistor output
Response time
0.5ms or less
Maximum load current
0.1A/pointRated load voltage
12 to 24VDCNumber of outputs
64 pointsTransistor
output
External connections
40-pin
connector ×2 Source type Protection
Function
■ LY40PT5PTransistor output
Response time
0.5ms or less
Maximum load current
0.5A/pointRated load voltage
12 to 24VDCNumber of outputs
16 pointsTransistor
output
External connections
18-point
terminal blockSource type Protection
Function
Response time
0.5ms or less
Maximum load current
0.5A/pointRated load voltage
12 to 24VDCNumber of outputs
16 pointsTransistor
output
External connections
18-point
terminal blockSink type Protection
Function
■ LY40NT5PTransistor output
NEW
NEW
NEW
NEW
Protection Function
Protection Function
19 20
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
•Modulesarebuiltwithcountermeasuresincaseofexternalloadshort-circuitstoprotectagainstover-currentand over-heating.
■ Output module specifications[Contact output module]
Item LY10R2
Number of output points 16 points
Rated switching voltage, current 24VDC 2A (resistive load)/point, 8A/common / 240VAC 2A (COSf=1)/point, 8A/common
Minimum switching load 5VDC 1mA
Maximum switching load 264VAC 125VDC
Responsetime
OFF to ON 10ms or less
ON to OFF 12ms or less
Life
Mechanical 20 million times or more
Electrical
Usage environment Switching life
Rated switching voltage/current, rated load 100 thousand times
200VAC 1.5A, 240VAC 1A (COSf = 0.7) 100 thousand times
200VAC 0.4A, 240VAC 0.3A (COSf = 0.7) 300 thousand times
200VAC 1A, 240VAC 0.5A (COSf = 0.35) 100 thousand times
200VAC 0.3A, 240VAC 0.15A (COSf = 0.35) 300 thousand times
24VDC 1A, 100VDC 0.1A (L/R = 7ms) 100 thousand times
24VDC 0.3A, 100VDC 0.03A (L/R = 7ms) 300 thousand times
Maximum switching frequency 3600 times/hour
Surge suppressor —
Fuse —
Common terminal arrangement 16 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: 16 input points)
External connections 18-point terminal block
5VDC internal current consumption 460mA (TYP. all points ON)
Weight 0.21kg
[Transistor output module (Sink type)]Item LY40NT5P[NEW] LY41NT1P LY42NT1P
Number of output points 16 points 32 points 64 points
Rated load voltage 12 to 24VDC (+20%/-15%)
Maximum load current 0.5A/point, 5A/common 0.1A/point, 2A/common
Maximum inrush current Current is limited by the overload protection function.
Leakage current at OFF 0.1mA or less
Maximum voltage drop at ON 0.2VDC (TYP.) 0.5A,0.3VDC (MAX.) 0.5A 0.1VDC (TYP.) 0.1A, 0.2VDC (MAX.) 0.1A
Response timeOFF to ON 0.5ms or less
ON to OFF 1ms or less (rated load, resistance load)
Surge suppressor Zener diode
Fuse —
Protection function
Overload protection
Limited current when detecting overcurrent (overload protection):
1.5 to 3.5A/point.Activated in increments of 1 point.
Overcurrent detection/overload protection limit current: 1 to 3A/point,Activated in increments of 1 point
Overheat protection Activated in increments of 1 point
External power supply
Voltage 12 to 24VDC (+20%/-15%, ripple ratio within 5%)
Current 9mA (at 24VDC)/common 13mA (at 24VDC)/common 9mA (at 24VDC)/common
Common terminal arrangement 16 points/common 32 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: 16 output points) 32 points (I/O assignment: 32 output points) 64 points (I/O assignment: 64 output points)
External connections 18-point terminal block 40-pin connector 40-pin connector ×2
5VDC internal current consumption 100mA (TYP. all points ON) 140mA (TYP. all points ON) 190mA (TYP. all points ON)
Weight 0.15kg 0.11kg 0.12kg
Module protection features Output modules[LY40NT5P, LY41NT1P, LY42NT1P, LY40PT5P, LY41PT1P, LY42PT1P]
Product lineup (For CC-Link IE Field Network Head Module)
[Transistor output module (Source type)]Item LY40PT5P[NEW] LY41PT1P[NEW] LY42PT1P[NEW]
Number of output points 16 points 32 points 64 points
Rated load voltage 12 to 24VDC (+20%/-15%)
Maximum load current 0.5A/point, 5A/common 0.1A/point, 2A/common
Maximum inrush current Current is limited by the overload protection function.
Leakage current at OFF 0.1mA or less
Maximum voltage drop at ON 0.2VDC (TYP.) 0.5A,0.3VDC (MAX.) 0.5A
0.1VDC (TYP.) 0.1A, 0.2VDC (MAX.) 0.1A
Response timeOFF to ON 0.5ms or less
ON to OFF 1ms or less (rated load, resistance load)
Surge suppressor Zener diode
Fuse —
Protection function
Overload protection Overcurrent detection: 1.5A or more/point.Activated in increments of 1 point.
Limited current when detecting overcurrent (overload protection):1 to 3A/point.
Activated in increments of 1 point.
Overheat protection Activated in increments of 1 point. Activated in increments of 2 point.
External power supply
Voltage 12 to 24VDC (+20%/-15%, ripple ratio within 5%)
Current 17mA (at 24VDC)/common 20mA (at 24VDC)/common
Common terminal arrangement 16 points/common 32 points/common
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: 16 output points)
32 points (I/O assignment: 32 output points)
64 points (I/O assignment: 64 output points)
External connections 18-point terminal block 40-pin connector 40-pin connector ×2
5VDC internal current consumption 100mA (TYP. all points ON) 140mA (TYP. all points ON) 190mA (TYP. all points ON)
Weight 0.15kg 0.11kg 0.12kg
L Y 4 0 NT 5 P ➀ ➁ ➂ ➃ ➄ ➅
■ How to read I/O unit product numbers
Number Item Code Specification
➀ Module typeX Input
Y Output
Number Item CodeSpecification
DC input Transistor output module Contact output
➁ Voltage specification1 — 24 VDC / 240 VAC
4 24 VDC 12 to 24 VDC —
Number Item CodeSpecification
DC input Transistor output module Contact output
➄ Current specification
1 — 0.1A —
2 — — 2A
4 4mA — —
5 — 0.5A —
6 6mA — —
Number Item Code Specification
➂ I/O points
0 16 points
1 32 points
2 64 points
Number Item Code Specification
➅ Extra Specifications P Includes protection function
Number Item Code Specification
➃ I/O type
C DC input (positive / negative shared common)
NT Transistor output module (Sink type)PT Transistor output module (Source type)
R Contact output
21 22
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts• Thescalingfunctionconvertsvaluesdirectlytoeasy-to-understandunitswithoutanyprogramming.
• Speedupscantimesbyeliminatingtheconversionprocessbysequenceprogram.
Normally an analog input of 4 to 20mA is converted to a digital value from 0 to 20000. Using the scaling feature, the same input can result in a digital value of ±20000.
Scaling settings for A to D conversion module (example)
Input current (mA) Digital output value Scaling value
4 0 −20000
8 5000 −10000
12 10000 0
16 15000 10000
20 20000 20000
L60DA4L60AD4
4 8 12 16 20
0
20000
Digital output value
Input current (mA)
[Before scaling] [After scaling]
Scaling: Valid
Scaling upper limit value“20000”
Scaling lower limit value“-20000”
20000
−20000
Scaling value
20128 16
0
4 Input current (mA)
Scaling upper/lower limit values can be set within the range from-32000 to 32000.
■ L60AD4
■ L60DA4
Conversion speed
20μs/ch
Conversion speed
20μs/ch
Scaling function
Scaling function
GX Works2
Error history
GX Works2
Error history
Warning output function
Warning output function
Conversion speed switching
function
Analog outputHOLD/CLEAR
function
Input signal error detection
function
Input voltage
-10 to 10VDC
output voltage
-10 to 10VDC
Number of inputs
4 points(channels)
Number of outputs
4 points(channels)
Resolution
1/20000
Resolution
1/20000
Input current
0 to 20mADC
output current
0 to 20mADC
Accuracy
±0.1%
Accuracy
±0.1%
•Anextremelyfinelevelofcontrolispossiblewithhigh resolution (1/20000) in all ranges.•TakeadvantageofCPUperformancewith20μs/ch
high-speed analog conversion rates.
•Experiencemorereliablecontrolwithconversionaccuracy as high as ±0.1%.
•ThesettingscreensinGXWorks2includehighlydetailed information to assist in making the correct settings.
•Theconversionspeedcanbeswitchedbetween20μs/ch,80μs/ch,and1ms/ch.Byselectingtheappropriate conversion speed according the connected device's specifications, stable analog input signals can be obtained even in noisy environments.
■ SpecificationsItem L60AD4 [Analog input module] L60DA4 [Analog output module]
Number of analog input points 4 points (ch)
Analog inputVoltage -10 to 10VDC (Input resistance value 1MΩ) -10 to 10VDC (External load resistance value 1kΩ to 1MΩ)
Current 0 to 20mADC (Input resistance value 250Ω) 0 to 20mADC (External load resistance value 0Ω to 600Ω)
Digital output-20480 to 20479
When usingscaling function -32768 to 32767
I/O characteristics, resolution
Analog input range Digital output value Resolution
Voltage
0 to 10V
0 to 20000
500μV
0 to 5V 250μV
1 to 5V 200μV
-10 to 10V-20000 to 20000
500μV
Users range setting 307μV*1
Current
0 to 20mA0 to 20000
1000nA
4 to 20mA 800nA
Users range setting -20000 to 20000 1230nA*1
Analog output range Digital value Resolution
Voltage
0 to 5V0 to 20000
250μV
1 to 5V 200μV
-10 to 10V-20000 to 20000
500μV
Users range setting 333μV*1
Current
0 to 20mA0 to 20000
1000nA
4 to 20mA 800nA
Users range setting -20000 to 20000 700nA*1
Accuracy
Ambient temperature25±5°C
Within ±0.1% (±20digit) Within±0.1%(voltage:±10mV,current:±20μA)
Ambient temperature0 to 55°C
Within ±0.2% (±40digit) Within±0.3%(voltage:±30mV,current:±60μA)
Conversion speedHighspeed:20μs/ch
Mediumspeed:80μs/chLow speed: 1ms/ch
20μs/ch
Absolute maximum input Voltage: ±15V, Current: 30mA*2 —
Output short protection — Available
External power supply
— 24VDC (+20%/-15%)
— Ripple, spike 500mVP-P or lower
— Inrushcurrent:4.3A,1000μsorshorter
— Current consumption: 0.18A
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: Intelligent 16 points)
External connections 18-point terminal block
5VDC internal current consumption 0.52A 0.16A
Weight 0.19kg 0.20kg
*1: Maximum resolution in users range settings.*2: Maximum instantaneous current value that will not cause destruction of the internal components. The maximum constant input current value is 24mA.
Setting details are listed so referencing the manual is unnecessary.
Analog Input Module
Analog Output Module
Reduce programming man-hours using the scaling function
High-speed conversion of 20μs/ch
High resolution of 1/20000
Ensure stability with variable conversion speedHigh conversion accuracy
of ±0.1%L60AD4
L60DA4
L60DA4
L60DA4L60AD4
L60AD4
L60AD4
L60DA4L60AD4Parameters are easily set without a manual
Product lineup (For CC-Link IE Field Network Head Module)
23 24
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
■ LD77MH4
*SSCNET (Servo System Controller NETwork)
Number of control axes
1 axis 4 axes 8 axes 16 axes 32 axes
High
Low
Ser
vo fu
nctio
n an
d pe
rfor
man
ce
Simplemotion module
LD77MH16 NEW
LD75P4
Positioningmodule
LD75D4
Simplemotion module
LD77MH4
iQ motioncontroller
Stand-alonemotion controller
Positioning control function
Synchronous control function
External encoder
Manual pulse generator
operation function
OPR control function
Synchronous control function
Cam
Synchronous control function
Phase compensation
2-axis interpolation
(Circular interpolation)
Connection system
SSCNET III-compatible
Number of control axes
4 axes
Speed/torquecontrol function
Positioning data
600 data/axis
4-axis interpolation
(Linear interpolation)
Simple Motion Module
Synchronous control function
Cam
Synchronous control function
Phase compensation
Synchronous control function
External encoder
Speed/torquecontrol function
OPR control function
4-axis interpolation
(Linear interpolation)
2-axis interpolation
(Circular interpolation)
Number of control axes
16 axes
Positioning control function
Manual pulse generator
operation function
Positioning data
600 data/axis
Connection system
SSCNET III-compatible
■ LD77MH16NEW
Product lineup (For CC-Link IE Field Network Head Module)
[ Use a synchronous encoder with synchronous control ]
Input pulses from a synchronous encoder can be used to perform • synchronous control and cam control.Connect an incremental synchronous encoder directly to the LD77MH • built-in interface, or connect an absolute synchronous encoder SOON via servo amplifier. Option modules are no longer necessary.To Further improve the synchronization accuracy, the phase compensation • function, designed to compensate for synchronous encoder delays, can be used.
[ Standard mark detection function ] NEW
The built-in mark detection signal interface allows these units to be used in • packaging systems for example, without additional option modules.
[ Automatic cam data generation for rotary cutter ]
Complicated cam data for rotary cutters can • be automatically generated just by specifying a few parameters like the sheet length and synchronization width.
[ Cam control ]
Cam control may be used alone or combined with synchronous control.•
[ Positioning control ]
Support for a multitude of applications thanks to a wide variety • of control formats including linear interpolation control (up to 4 axes), 2-axis circular interpolation control, fixed feed control and continuous orbit control.Use a sequence program to set the positioning address, speed, • etc. for easy automatic operation.Quickly implement powerful auxiliary functions such as step • operation, target position change, M codes, and the skip function.
XY table Sealant application
2-axis linear interpolation •2-axis circular interpolation •3-axis linear interpolation •Continuous orbit control •
Continuous orbit control •High-speed, high-accuracy orbit •calculationLinear/circular interpolation •
X
Y
Z
r2r1
X
Y
Z
[ Speed control and torque control ]
Tension control applications such as winding and rewinding are • supported.Switch from positioning control, to speed and torque control, and • back to positioning control. Because the present location is tracked even in speed and torque control mode, it is possible to maintain the current absolute position when returning to positioning control. Servomotor
Unwindingaxis
Windingaxis
Servomotor
Tension detector
Tension detector
Servomotor
Example application for cam control:
To create a movement path around a workpiece using positioning control, axis 2 waits for axis 1 to complete the move from P1 to P2 before it begins moving from P2 to P3. By using cam control, axis 2 does not need to wait for axis 1 to complete its movement and the in position time can be shortened.
Workpiece
P1
P2
P3
�Positioning control
Axis 1 motor speed
Axis 2 motor speed
Axis 1 motor speed
Axis 2 motor speed
Time shortening
Cam data
Cam data
Axis 1 BUSY signal
�Cam control
INCsynchronous
encoder
Mark sensor
Rotary cutter
Countless applications are possible
A variety of control types including positioning control, speed control, torque control, cam control and
synchronous control can be implemented easily with simple parameter settings and a sequence program.
Many functions in a compact design
Speed
Time
Sheet length Cam dataSheet synchronization width
Sheet synchronization width
Stroke ratio
Time
GOT
Input
Cam resolution
Sheet length
Sheet synchronization width
Synchronous axis length
25 26
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Product lineup (For CC-Link IE Field Network Head Module)
■ Specifications Item LD77MH4 LD77MH16[NEW]
Number of control axes 4 axes 16 axes
Operation cycle 0.88ms 0.88ms/1.77ms*1
Interpolation function Linear interpolation(Up to 4 axes),Circular interpolation(2 axes)
Control system PTP (Point To Point) control, path control (both linear and arc can be set), speed control, torque control, speed-position switching control, position-speed switching control
Acceleration/deceleration process Trapezoidal acceleration/deceleration, S-pattern acceleration/deceleration
Compensation function Backlash compensation, Electronic gear, Near pass function
Synchronous control External encoder, Cam, Phase Compensation, Cam generated automatically
Control unit mm, inch, degree, pulse
Positioning data 600 data (positioning data No. 1 to 600)/ axis (Can be set with GX Works2 or PLC program.)
Backup Parameters, positioning data, and block start data can be saved on flash ROM (battery-less backup)
OPR control
Machine OPR control Near-point dog method, Count method 1), Count method 2), Data set method, scale origin signal detection method
Fast OPR control Provided
Sub functions OPR retry, OP shift
Position control
Position control
Linear control 1-axis linear control, 2-axis linear interpolation control, 3-axis linear interpolation control, 4-axis linear interpolation control(Composite speed, Reference axis speed)
Fixed-feed control 1-axis fixed-feed control, 2-axis fixed-feed control, 3-axis fixed-feed control, 4-axis fixed-feed control
2-axis circular interpolation control sub point designation, center point designation
Speed control 1-axis speed control, 2-axis speed control, 3-axis speed control, 4-axis speed control
Speed-position switching control INC mode, ABS mode
Position-speed switching control INC mode
Other control
Current value changing Changing to a new current value using the positioning data , Changing to a new current value using the start No.
NOP instruction Provided
JUMP instruction Unconditional JUMP, Conditional JUMP
LOOP,LEND Provided
High-level positioning control Block start, Condition start, Wait start, Simultaneous start, Repeated start
Manual control
JOG operation Provided
Inching operation Provided
Manual pulse generator operation Possible to connect 1 module (Incremental)Unit magnification (1 to 10000times)
Expansion control Speed-torque control Speed control without positioning loops, Torque control without positioning loops
Absolute position system Connect a battery to the servo amplifier to ensure compatibility
Synchronous encoder interface Up to 4 channel (internal interface , servo amplifier, via the PLC CPU interface )
Internal interface 1channel (Incremental)
Via servo amplifier Support coming soon
Functions that limit control
Speed limit function Speed limit value, JOG speed limit value
Torque limit function Torque limit value_same setting, torque limit value_individual setting
Forced stop function valid/invalid setting
Software stroke limit function Movable range check with current feed value, movable range check with machine feed value
Hardware stroke limit function Provided
Functions that change control details
Speed change function Provided
Override function Provided
Acceleration/deceleration time change function Provided
Torque change function Provided
Target position change function Target position address and target position speed are changeable
Other functions
M code output function Provided
Step function Deceleration unit step, Data No. unit step
Skip function Via sequence CPU, Via external command signal
Teaching function Provided
Mark detection function
Mark detection mode (Continuous Detection mode, Specified Number of Detections mode, Ring Buffer mode)
mark detection signal 4points
mark detection setting 4 16
Optional data monitor function 4points/axis
Master-slave operation function Provided
Amplifier-less operation function Provided
Digital oscilloscope function bit data :8channels, word data: 4channels bit data :16channels, word data: 16channels *2
Starting time*3
1-axis linear control
0.88ms
1-axis speed control
2-axis linear interpolation control (Composite speed)
2-axis linear control (Reference axis speed)
2-axis circular interpolation control
2-axis speed control
3-axis linear interpolation control (Composite speed)
3-axis linear interpolation control (Reference axis speed)
3-axis speed control
4-axis linear interpolation control
4-axis speed control
Maximum connection distance between drive units 50m
Maximum number of modules specification Counts as 2 modules
Number of occupied I/O points 32 points (I/O assignment: 32 points for intelligent function module)
Servo amplifier connection system SSCNET 3-compatible (50Mbps)
5VDC internal current consumption 0.55A 0.70A
Weight 0.22kg
*1: Default value is 1.77 ms. If necessary, check the operation time and change to 0.88 ms. *2: 8CH word data and 8CH bit data can be displayed in real time. *3: The starting time varies with conditions. For details, refer to the manual.
Cam Data Cam Data List
Synchronous Control Parameter Settings
Complicated programs are unnecessary for synchronous • control because it can be implemented easily using parameter settings. Start and stop synchronous control for each axis. • Use the synchronous control axis and positioning control axis together.Convey the travel value of main shaft to the output axis via • the clutch. NEW
Create cam profiles unrestricted by existing concepts of electronic cam control.• Change the acceleration, speed, stroke, and jerk while simultaneously seeing how it effects the profile. • Easily check created cam data by viewing them as thumbnails. • Import and export cam data in CSV format.•
Axis MonitorPositioning TestDigital Oscilloscope
[ Digital oscilloscope function ]
Collection of data from the Simple Motion Module is • synchronized with the operation cycle and waveform displays to facilitate an efficient start up.The assistant function explains each step.• Use the purpose-based probe setting to easily set • frequently-viewed data.Sample 16CH word and 16CH bit data and display 8CH • words and 8CH bits in real time. NEW
[ Monitor and test functions ]
Complete the system installation and perform operational • checks easily using powerful monitor and test functions.Select items to be displayed on the monitor using a wealth • of information monitoring options. NEW
The test function can be used to check basic operations • without a sequence program.
Perfect synchronous control is easy to achieve
Replace mechanical gears, shafts, speed change
gears, cams, etc. and generate synchronous control
operations using software.
Cam control made simple
Create cam data patterns easily.
Simplified debugging and commissioning
27 28
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
•Chosenbetweenautomatictrapezoidalacceleration/deceleration or S-curve acceleration/deceleration in accordance with machine characteristics such as the amount of load or vibration characteristics.
* S-curve acceleration/deceleration cannot be used with stepping motors.
•Monitoronlineorsaveandreviewcommanddatasuchasspeed,simultaneousstart,anddualaxisinterpolation routines using customizable graphs.
•Controlhighresolutiondevicessuchaslinear servos and direct drive motors without compromising speed.
*LD75D4
LD75D4 4Mpulse/s, maximum 10m
LD75P4 200kpulse/s, maximum 2m
Automatic trapezoidal acceleration/decelerationIs a system in which the acceleration and deceleration changes linearly based on acceleration/deceleration time and the speed-limit value set by users.
S-curve acceleration/decelerationIs a system in which acceleration/deceleration changes gradually based on acceleration/deceleration time, speed-limit, and the S-curve ration value (1 to 100%).
Speed
Time
Speed
Time
■ LD75P4Open collector
■ LD75D4Differential driver
Positioning data
600 data/axis
Positioning data
600 data/axis
Positioning control function
Positioning control function
GX Works2
Error history
GX Works2
Error history
Speed control function
Speed control function
OPR control function
OPR control function
Connection method
Open collector
Connection method
Differential driver
Number of control axes
4 axes
Number of control axes
4 axes
Maximum connection distance
2m
Maximum connection distance
10m
Maximum output pulse
200kpulse/s
Maximum output pulse
4Mpulse/s
Trace function - waveform display Trace function - location trace display
*These screens shots represent software still under development and are subject to change.
•GXWorks2containssupporttoolstohelpconfigureintelligent function modules. All of the required information to configure and revise complicated parameter settings is included so it is not necessary to reference a manual.
■ SpecificationsItem LD75P4 [Open collector] LD75D4 [Differential driver]
Number of control axes 4 axes
Interpolation function 2-axis/3-axis/4-axis linear interpolation, 2-axis circular interpolation
Control system
PTP (Point To Point) control,path control (both linear and arc can be set),
speed control, speed-position switching control,position-speed switching control
Control unit mm, inch, degree, pulse
Positioning data 600 data (positioning data No.1 to 600)/axis(Can be set with peripheral device or sequence program.)
Backup Parameters, positioning data, and block start data can be saved on flash ROM (battery-less backup)
Positioningcontrol
Positioning control system
PTP*1 control INC system, ABS system
Speed-position switching control INC system, ABS system*2
Position-speed switching control INC system
Path control INC system, ABS system
Positioning control range
In ABS system
-214748364.8to214748364.7(μm)-21474.83648 to 21474.83647 (inch)
0 to 359.99999 (degree)-2147483648 to 2147483647 (pulse)
In INC system
-214748364.8to214748364.7(μm)-21474.83648 to 21474.83647 (inch)
-21474.83648 to 21474.83647 (degree)-2147483648 to 2147483647 (pulse)
In speed-position switching control (INC mode)/position-speed switching control
0to214748364.7(μm)0 to 21474.83647 (inch)
0 to 21474.83647 (degree)0 to 2147483647 (pulse)
In speed-position switching control (ABS mode)*2 0 to 359.99999 (degree)
Speed command
0.01 to 20000000.00 (mm/min)0.001 to 2000000.000 (inch/min)
0.001 to 2000000.000 (degree/min)1 to 4000000 (pulse/s)
Acceleration/deceleration system selection Trapezoidal acceleration/deceleration, S-curve acceleration/deceleration
Acceleration/deceleration time 1 to 8388608msFour patterns can be set for each of acceleration time and deceleration time
Sudden stop deceleration time 1 to 8388608ms
OPR method 6 types
Starting time*3
1-axis linear control 1.5ms
1-axis speed control 1.5ms
2-axis linear interpolation control (Composite speed) 1.5ms
2-axis linear control (Reference axis speed) 1.5ms
2-axis circular interpolation control 2.0ms
2-axis speed control 1.5ms
3-axis linear interpolation control (Composite speed) 1.7ms
3-axis linear interpolation control (Reference axis speed) 1.7ms
3-axis speed control 1.7ms
4-axis linear interpolation control 1.8ms
4-axis speed control 1.8ms
Pulse output method Open collector output Differential driver output
Maximum output pulse 200kpulse/s 4Mpulse/s
Maximum connection distance between drive units 2m 10m
Maximum number of modules specification Counts as 2 modules
Number of occupied I/O points 32 points (I/O assignment: 32 points for intelligent function module)
External connections 40-pin connector ×2
5VDC internal current consumption 0.55A 0.76A
Weight 0.18kg
*1: The abbreviation for Point To Point, referring to position control.*2: In speed-position switching control (ABS mode), "degree" is the only control unit available.*3: Starting times may vary depending on conditions. For details, refer to the manual.
*This screen shot represents software still underdevelopment and is subject to change.
Configure modules easily and with no manual thanks to the included settings information.
Positioning Modules
Reduce machine vibration by using the optimal acceleration/deceleration system
High-speed control of high resolution devices
Visualize positioning module buffer data
Configure modules without the need to reference a manual
Product lineup (For CC-Link IE Field Network Head Module)
29 30
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
•GXWorks2containssupporttoolstohelpconfigureintelligent function modules. All of the required information to configure and revise complicated parameter settings is included so it is not necessary to reference a manual.
•Itiseasytoachieveaccuratemeasurementofhighspeed pulses using the LD62D.
•Duetothewiderangeofsupportedpulsespeeds,the module is capable of supporting many different applications including various conveyor systems, work piece length measurement, and processing speed measurement.
LD62D
LD62DLD62
Drill
Pulse
Temporary stop(coincidence output)
Fixed feeding (drilling holes)
■ LD62DC input
■ LD62DDifferential input
Linear counter function
Linear counter function
Disable count function
Disable count function
Latch counter function
Latch counter function
Sampling counter function
Sampling counter function
Periodic pulse counter function
Periodic pulse counter function
5/12/24VDC
input
Differential driver input
Number of channels
2ch
Number of channels
2ch
Ring counter function
Ring counter function
Coincidence output function
Coincidence output function
Presetfunction
Presetfunction
Maximum counting speed
200kpulse/s
Maximum counting speed
500kpulse/s
*This screen shot represents software still under development and is subject to change.
Configure modules easily and with no manual thanks to the included settings information.
■ SpecificationsItem LD62 [DC input] LD62D [Differential input]
Number of channels 2ch
Counting speed switch setting 10kpulse/s, 100kpulse/s, 200kpulse/s 10kpulse/s, 100kpulse/s, 200kpulse/s, 500kpulse/s
Count input signal
Phase 1-phase input (multiple of 1/2), CW/CCW, 2-phase input (multiple of 1/2/4)
Signal level ( A, B ) 5/12/24VDC 2 to 5mAEIA Standard RS-422-A differential type line driver level(Equivalent with AM26LS31 (manufactured by Texas Instruments Japan
Limited))
Counter
Maximum counting speed*1 200kpulse/s 500kpulse/s
Counting range -2147483648 to 2147483647
Type UP/DOWN preset counter and ring counter functions
Minimum count pulse width(Duty ratio 50%)
10kpulse/s 50μs
100kpulse/s 5μs
200kpulse/s 2.5μs
10kpulse/s 50μs
100kpulse/s 5μs
200kpulse/s 2.5μs
500kpulse/s 1μs
Minimum phase differential for 2-phase input
10kpulse/s 25μs
100kpulse/s 2.5μs
200kpulse/s 1.25μs
10kpulse/s 25μs
100kpulse/s 2.5μs
200kpulse/s 1.25μs
500kpulse/s 0.5μs
Coincidenceoutput
Comparison range Binary with 32-bit code(-2147483648 to 2147483647)
Comparison resultSet value < Count valueSet value = Count valueSet value > Count value
External input
Preset5/12/24VDC 2 to 5mA 5/12/24VDC 2 to 5mA (Differential type line drivers
conforming to EIA standard RS-422-A are also applicable.)Function start
Minimum inputresponse time
OFF to ON Function start: 0.5ms
ON to OFF Function start: 1ms
External output
Coincidence output 2 points/channel
Output voltage/current 12 to 24VDC 0.5A
Output response timeOFF to ON
0.1ms or less (rated load, resistive load)ON to OFF
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 16 points (I/O assignment: 16 points for intelligent function module)
External connections 40-pin connector
5VDC internal current consumption 0.31A 0.36A
Weight 0.13kg
*1: The counting speed is affected by the rising/falling pulse speed. For details, refer to the corresponding manual.
High-Speed Counter Modules
High-speed pulse measurement of 500kpulse/s
Configure modules without the need to reference a manual
Product lineup (For CC-Link IE Field Network Head Module)
31 32
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
•Builtindebuggingfunctionsincludeconfirmationofcommunicationsignalwirecondition,packetdatacontents,and a state monitor. These features effectively eliminate the need for an expensive network analyzer.
•Establishcommunicationwithdevicesquicklybysimply selecting a device from the pre-defined protocol library included in GX Works2.
•Evenwhenadesiredexternaldeviceisnotincluded in the predefined protocol library, it is still easy to define a custom protocol and establish communications.
•Theprotocoleditingwindowsallowtheconfirmationof settings at a glance for quick and easy configuration.
*Available for only channel 1
*Available for only channel 1
■ LJ71C24
■ LJ71C24-R2
Communication system
MC protocol
Communication system
MC protocol
GX Works2
Error history
GX Works2
Error history
Interface
RS-422/485
Maximum transmission speed
230.4kbps*
Interface
RS-232
Interface
2x RS-232
Communication system
Pre-defined protocol
Communication system
Pre-defined protocol
Communication system
Nonprocedural protocol
Communication system
Nonprocedural protocol
Communication system
Bidirectional protocol
Communication system
Bidirectional protocol
Maximum transmission speed
230.4kbps*
Simply select a device you want to establish communication with
Define custom communications
Circuit traceNetwork transmission data are saved to the data area inside the module for review. There is no need for devices such as circuit analyzers.
Protocol execution logInformation about each data packet sent and received such as protocol name, start/end times and dates, and end results can be saved to the buffer memory inside the module.
•Usingthepredefinedprotocolfeaturemeansthatonly a few simple ladder instructions are required to communicate with external devices. In the past, massive amounts of ladder program code had to be dedicated to the communication process. This reduction in ladder code reduces scan times and allows more space for other program code.
•GXWorks2containssupporttoolstohelpconfigureintelligent function modules. All of the required information to configure and revise complicated parameter settings is included so it is not necessary to reference a manual.
■ SpecificationsItem LJ71C24 LJ71C24-R2
Interfacech1 RS-232-compliance (D-Sub 9P female) RS-232-compliance (D-Sub 9P female)
ch2 RS-422/485-compliance (2-piece terminal block) RS-232-compliance (D-Sub 9P female)
Communication system
Line Full-duplex/half-duplex communications
MC protocol Half-duplex communications
Pre-defined protocol
Full-duplex/half-duplex communicationsNonprocedural protocol
Bidirectional protocol
Synchronization method Start-stop synchronization method
Transmission speed
50bps/300bps/600bps/1200bps/2400bps/4800bps/9600bps/14.4kbps/19.2kbps/28.8kbps/38.4kbps/57.6kbps/115.2kbps/230.4kbpsTransmission speed 230.4kbps is only available for channel 1.
Total transmission speed of two interfaces is available up to 230.4kbps.Total transmission speed of two interfaces is available up to 115.2kbps when the communication data monitoring function is used.
Data foramat
Start bits 1
Data bits 7 or 8
Parity bits 1 (vertical parity) or none
Stop bits 1 or 2
Access cycle
MC protocol Processes one request during installed C24 CPU module END processing. (Number of scans that must be processed/number of link scans depends on the contents of the request.)
Pre-defined protocol Sends or receives data when requested with the dedicated instruction (CPRTCL).
Nonprocedural protocol Sends each time a send request is issued. Can receive at any time.
Bidirectional protocol
Error detection
Parity check All protocols and when ODD/EVEN is selected by parameter.
Sum check code MC protocol/bidirectional protocol selected by parameter.
For the pre-defined protocol, whether or not a sum check code is needed depends on the selected protocol. Nonprocedural protocol selected by user frame.
Transmission control
RS-232 RS-422/485
DTR/DSR (ER/DR) control Enabled Disabled
RS/CS control Enabled Disabled
CD signal control Enabled Disabled
DC1/DC3 (Xon/Xoff) controlDC2/DC4 control Enabled Enabled
•DTR/DSRsignalcontrolandDCcodecontrolareselectedbytheuser.
Transmission distance(Overall distance)
RS-232 Maximum 15m
RS-422/485 Maximum 1200m (overall distance) —
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 32 points (I/O assignment: 32 points for intelligent function module)
5VDC internal current consumption 0.39A 0.26A
Weight 0.17kg 0.14kg
X1036
X20GP.CPRTCL U0 K1 K1 D10
SET M101
SET M102
D10MOV D101
M0
M072
M1
M1
A few lines of ladder code tobegin communication is
all that is necessary.
Configure modules easily and with no manual thanks to the included settings information.
Serial Communication Modules
Quick connection using pre-defined protocols Easily define custom protocols
Enhanced debugging and support functions
The number of ladder program steps can be significantly reduced
Configure modules without the need to reference a manual
Product lineup (For CC-Link IE Field Network Head Module)
33 34
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
•WithsuchalargeselectionofCC-Linkopennetwork compatible devices, constructing a control system is easy.
Even applications requiring vast amounts of data transmissions can be satisfied because CC-Link Version 2.0 is supported.
■ SpecificationsItem LJ61BT11
Transmission speed 156kbps/625kbps/2.5Mbps/5Mbps/10Mbps
Maximum overall cable distance (Maximum transmission distance) 1200m (without repeater, varies according to the transmission speed.)
Maximum number of connected stations (master station) 64
Number of occupied stations (local station) 1 to 4 stations (The number of stations can be switched using the GX Works2 parameter setting.)
Maximum number oflink points per system*1
Remote I/O (RX, RY) 2048 points
Remote register (RWw) 256 points (master station ➝ remote device station/local station/intelligent device station/standby master station)
Remote register (RWr) 256 points (remote device station/local station/intelligent device station/standby master station ➝ master station)
Number of link points per station*1
Remote I/O (RX, RY) 32 points (local station is 30 points)
Remote register (RWw) 4 points (master station ➝ remote device station/local station/intelligent device station/standby master station)
Remote register (RWr) 4 points (remote device station/local station/intelligent device station/standby master station ➝ master station)
Communication method Broadcast polling method
Synchronous method Frame synchronization method
Encoding method NRZI method
Transmission path Bus (RS-485)
Transmission format Conforms to HDLC
Error control system CRC (X16+X12+X5+1)
RAS function Automatic return function
Slave station cut-off functionError detection via link special relay/register
Connection cable CC-Link dedicated cables compatible with Ver.1.10
Maximum number of modules specification Counts as 1 module
Number of occupied I/O points 32 points (I/O assignment: 32 points for intelligent function module)
5VDC internal current consumption 0.46A
Weight 0.15kg
*1: Indicates the number of link points for Remote net Ver.1 mode.
*Link points for CC-Link Ver.2.0 master station
■ LJ61BT11
CC-Link Ver.2.0
Maximum transmission speed
10Mbps
Master/local station
Standby master station function
Local stationtransmission speed
auto-tracking function
Remote I/O
8192 points*Remote register
2048 words*
■ Power supply module specificationsItem L61P L63P
Input power supply 100 to 240VAC (-15% to +10%) 24VDC (-35% to +30%)
Input frequency 50/60Hz (-5% to +5%) —
Input voltage distortion Within 5% —
Maximum input apparent power 130VA —
Maximum input power — 45W
Inrush current 20A, within 8ms 100A, within 1ms (24VDC input)
Rated output current (5VDC) 5A
Overcurrent protection (DC5V) 5.5A or more
Overvoltage protection 5.5 to 6.5V
Efficiency 70% or more
Allowable momentary power failure time Within 10ms Within 10ms (24VDC input)
Weight 0.32kg 0.29kg
■ END cover with error terminal specificationsItem L6EC-ET
ERR. terminal
Rated switching voltage, current 24VDC 0.5A
Minimum switching load 5VDC, 1mA
Response timeOFF to ON 10ms or less
ON to OFF 12ms or less
LifeMechanical 20 million times or more
Electrical Rated switching voltage/current: 10 million times or more
Surge suppressor —
Fuse —
Applicable wire size 0.3 to 2.0mm2 (AWG22 to 14) (Twisted wire/Solid wire)
External connections Spring clamp terminal block
5VDC internal current consumption 0.06A
Weight 0.11kg
■ L61P
■ L6EC-ET
■ L63P
Output
5VDC, 5AOutput
5VDC, 5A
Input
100 to 240VAC
Error outputRelay
Input
24VDC
CC-Link Master/Local Module
Connect with a huge selection of device types using CC-Link
Power Supply Modules
END Cover with Error Terminal
Product lineup (For CC-Link IE Field Network Head Module)
35 36
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Item Specifications
Maximum number of links per network
RX 16 K points (16384 points, 2 Kbytes)
RY 16 K points (16384 points, 2 Kbytes)
RWr 8 K points (8192 points, 16 Kbytes)
RWw 8 K points (8192 points, 16 Kbytes)
Maximum number of links per station
RX 2 K points (2048 points, 256 bytes)
RY 2 K points (2048 points, 256 bytes)
RWr 1 K points (1024 points, 2 Kbytes)
RWw 1 K points (1024 points, 2 Kbytes)
Communication speed 1Gbps
Maximum stations per network 121 (1 master plus 120 slave stations)
Cable type Ethernet cable (Category 5e or higher)
Total extension distance (max.)
Line topology 12000 m (with 1 master and 120 slaves connected)
Star topology Depends on the system configuration *1
Ring topology 12100m (with 1 master and 120 slaves connected)
Maximum station-to-station distance 100m
Maximum number of networks 239
Topology Line, star, line and star mixed, or ring (available soon) topology*2
*1) Connect up to 20 hubs per network.*2) Support for Ring topology requires the following modules and software.
CC-Link IE Field Network Master / Local Module (QJ71GF11-T2) whose first five serial number digits are 12072 or later GX Works2 Version 1.40S or later
Ring topology cannot be combined with other network topologies.Using ring topology, the CC-Link IE Field Network PC Interface Board (Q81BD-J71GF11-T2) does not support being the master station.
Item Specifications
Ethernet cable
Straight Category 5e cable, double shield SF / UTP (Overall Foil and Braided Shield / Unshielded Twisted Pair)
StandardComplies with the following standards
•IEEE802.31000BASE-T•ANSI/TIA/EIA-568-B(Category5e)
Connector Category 5e or better, RJ-45 (8P8C) T568B
Note) Use the cables recommended by the CC-Link Partner Association for the CC-Link IE Field Network. CC-Link IE Field Network cables are not compatible with the CC-Link IE Controller Network.
Performance specifications
Cable specifications
Examples of network topologies
Ring topology
Line topology Star topology
Cables
SC-E5EW Series
Inline coupler
SPAD-RJ45S-E5E
Features
¡This straight cable is compliant with the 1000BASE-T physical layer standard. It is covered with a double-shield and is highly resistant to external noise.
¡Available in lengths starting from 0.5m and 1m up to 100m in 1 meter increments.
Features
¡8 conductor RJ45 female to female, shielded, fits standard type Keystone Wall Plate.
¡Can be used in patch panels, wall jacks, or to extend cable lengths.
Cables and accessoriesProduced by Mitsubishi Electric System & Service
Item Specifications
Cable type (Double shielded/STP) Straight cable
Number of wires in core 8 wires (4 twisted pairs)
Double shield Aluminum/polyester tape, Tin-plated annealed copper wire braid
Installation environment Indoor/Outdoor
Finished outside diameter
Indoor : 6.8mm PVCOutdoor : 10mm LAP sheath
Connector RJ45 (8P8C) shielded,Straight connection
Conforming standards
IEEE802.3 1000BASE-TANSI/TIA/EIA-568-B (Category 5e)
ISO/IEC 11801
Item Specifications
Adaptable connector RJ45 (8P8C) shielded
Operable temperature −10°C to +60°C
Conforming standards
IEEE 802.3 1000BASE-TANSI/TIA/EIA-568-B
(Category 5e)ISO/IEC 11801
Produced by Mitsubishi Electric System & Service
Station-to-station distance: max. 100 m
Localstation
Masterstation
Remotestation
Remotestation
Remotestation
Overall cable distance: 12000 m
Station-to-station distance: max. 100 m
Localstation
HUB HUB
Localstation
Remotestation
Remotestation
Remotestation
Masterstation
Station-to-station distance:max. 100 m
Overall cable distance: 12100 m
Localstation
Remotestation
Remotestation
Remotestation
Masterstation
37 38
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
General specifications
Item Specifications
Operable ambient temperature 0 to 55°C
Storage ambient temperature −25 to 75°C*1
Operable ambient humidity 5 to 95% RH*2, No condensation
Storage ambient humidity 5 to 95% RH*2, No condensation
Vibration resistance Compatible with JIS B 3502, IEC 61131-2
Frequency Constant acceleration Half amplitude Number of sweeps
With intermittent vibrations
5 to 9Hz – 3.5mm 10 times in each of the X, Y, and Z directions9 to 150Hz 9.8m/s2 –
With continuous vibrations
5 to 9Hz – 1.75mm–
9 to 150Hz 4.9m/s2 –
Shock resistance Compatible with JIS B 3502, IEC 61131-2 (147 m/s2, 3 times in each of the X, Y, and Z directions)
Operable ambient conditions No corrosive gas
Operable altitude*3 2000 m or lower
Installation place Inside the control box
Over voltage category *4 II or lower
Pollution degree *5 2 or lower
Device class Class!
*1) The allowable ambient storage temperature is −20 to 75°C when an AnS/A Series unit is included in the system.*2) The operable ambient humidity and storage ambient humidity are 10 to 90% RH when an AnS/A Series unit is included in the system.*3) Do not use or store your PLC in any place where the ambient atmospheric pressure exceeds 1 atm (atmospheric pressure at sea level). Contact your local Mitsubishi Electric representative if you wish to operate the PLC under such conditions, as malfunctions could occur.*4) Assigned based on where the equipment is connected relative to the public power distribution network as defined in IEC60664. Category II is applicable to equipment to which power is supplied from some fixed facility. As defined by the IEC, equipment with a rated voltage of 300 V or lower must be surge-resistant up to 2500 V.*5) This index specifies the worst environmental conditions the equipment is designed to function in. Pollution degree 2 specifies that the operating environment may only contain non-
conductive materials, however occasional temporary conductivity caused by condensation must be expected.
The general specifications are applicable to all products in the Q Series and L Series unless an exception is indicated. The Q Series and L Series equipment is designed to be installed and operate within the environment specified by the general specifications. For the general specifications of products provided by other manufacturers, contact the relevant manufacturer or distributer.The general specifications of jointly developed products may be different.For more information, please refer to the product manuals or contact your local Mitsubishi representative for details.
MEMO
For System Designers
High speed communication enables the sharing of large amounts of data in real time! ........ P.41■ Increase equipment and production line productivity ■Transfer large amounts of traceability data without slowing down the network
The dual-loop fiber optical cabling design is exceptionally fault-tolerant!......................................... P.42■There is no need to worry about the many sources of noise commonly present
in manufacturing environments
Cut costs by using commercially available Ethernet equipment!......................................................... P.44■Regardless of geographical location, network cables and equipment
are easy to purchase■Network cables and equipment are comparatively inexpensive
For Maintenance Technicians
This highly-reliable control network
is designed to transfer large amounts
of data at real-time speeds between
PLCs.
The CC-Link IE Control network
includes a variety of functions and
allows seamless communications
among other CC-Link networks.
The dual-loop fiber optical cabling design is exceptionally fault-tolerant!......................................... P.42■Maintain communication even in the event of cable breaks,
PLC errors, or power loss
Engineering tools make wiring problems and errors easy to diagnose!........................................... P.43■Minimize downtime with the ability to respond quickly to problems■Diagnose errors without having to physically go to each machine
Cut costs by using commercially available Ethernet equipment!......................................................... P.44■Regardless of geographical location, network cables and equipment
are easy to purchase■Network cables and equipment are comparatively inexpensive
CASE 2
CASE 4
CASE 3
CASE 1
CASE 2
CASE 4
39 40
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
41
Benefits of CC-Link IE Control Network
42
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
High speed communication enables the sharing oflarge amounts of data in real time!
1 Gbps high-speed communication
Deterministic, reliable performance helps to reduce takt time
Cyclic communication is stable and reliable
Improved quality of communication is achieved using a stable control period
The CC-Link IE Control network is based on gigabit Ethernet technology but uses an open, deterministic protocol to maintain a constant link scan time.The master/local module is compatible with nearly every Q series CPU module, allows large amounts of data to be shared among controllers at high speed and enables large scale distributed control systems.
The maximum number of link registers per station has been increased 8 fold!Transfer large amounts of recipe or other data in a single link scan!
16 K words 128 K words
The total bandwidth is divided between deterministic (cyclic) communication and transient (message) communication. The cyclic communication band, intended for I/O control, is fixed and will not suffer from degraded performance even when large volumes of traceability and diagnostic data are transferred via transient communication.
The dual-loop fiber optical cabling designis exceptionally fault-tolerant!
Ultra-reliable ring topology network
Designed to continue functioning even in the worst possible scenarios
The use of fiber optic cables which are completely immune to EMI and RFI noise allows the network to function in environments where other networks cannot. The dual loop design allows the network to continue functioning even if cables become damaged or the power is lost to a station. Additionally, CC-Link IE stations can be powered using an external supply. That allows communication to continue normally in the event of a loss of the primary power supply, without relying on the loop-back function.
NEW
For example... For example...
*1) To perform diagnostics or configure a network that uses more than 16 K link points per station, please use GX Works2 (Version 1.31H or later).
CASE 1
1Gbps
To the information network
GOT
1 Gbps(broadband)
Stabletiming
Cyclic communication band (for I/O control)
Transient (message) communication band (for traceability and other data)
System designer
I want to collect more data for traceability purposes.
I want to enhance the productivity of our equipment
and production line.
Amount of
information
Load
Communicationspeed
Largecapacity
Communicationstability
High-speedcommunication
Number of data sets In conventional systems, if one station goes down all stations stop communication.
Error
System designer
I want to ensure that communications can continue
even if there is an error.I'm worried about the
influence of noise.
Maintenance technician
CASE 2
makes it possible... makes it possible...
1Gbps
Communicationspeed
128Kwords
Maximum linkregisters External
powersupply
Multi-modeoptical fiber
cable
External powersource
External powersource
External powersource
External powersource
External powersource
External power source
Communication continues eventhough this station is between two
stations that have lost primary power.
Power failure (2 stations)
Power failure
Power failure to the PC
External power supply
Communication is maintainedby the loop-back function.
Loop-back function
Broken cable
Loop back
The external power source allowscommunication to continue.
GOT*1
43
Benefits of CC-Link IE Control Network
44
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Engineering tools make wiring problemsand errors easy to diagnose!
Easy diagnosis functions
Perform diagnostics and troubleshoot effectively regardless of experience
GX Works2 enables you to identify network errors at a glance. You can quickly identify the cause of a problem and implement the suggested remedy to minimize down time.
The network diagnostics tool automatically creates a graphical representation of the network. Using this diagram, cable problems and PLC errors are clearly visible allowing for fast response. Additionally, the condition of any remote station on the network can be monitored by directly accessing it from the same screen.
Cut costs by using commercially available Ethernet equipment!
Ethernet-based network
Built on global standards
CC-Link IE has been designed to make use of commercially available Ethernet components including cables, connectors, and adapters. Thanks to the common availability of these components, significant cost savings over alternative networks can be achieved.
For example... For example...
CASE 3
I need to be able to react faster if there is a problem.
I want to perform troubleshooting without
having to go to the machine every time.
Where is the problem...
OK
OK
Maintenance technician
Error
I was able toimmediately identify thecause of the problem.
How convenient!
GX Works2
Module error!
Errors arequickly identified
CASE 4
System designer
I want to use common components and general-purpose equipment...
I want to cut costs...
Maintenance technician
I want less expensive equipment and cables.
I want to be able to easily purchase network cables and equipment regardless of my
geographical location.
Networkdiagnosis
at-a-glance
Multimode opticalfiber cable
Single modeoptical fiber cable
Single modeoptical fiber cable
Factory A Factory B
Factory C
Media converter Media converter
Media converterMedia converter
Using media converters, cable lengths up to 15 km can be used.
Connections can use cable lengths up to 550 meters.
Relay adapter
Relay adapter
Adding another station is easily accomplished.
System expansion is planned.
Ethernet-based
Ethernet cable Ethernet connector Relay adapter
makes it possible... makes it possible...
45 46
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Network examples
Ethernet
Monitor the entire system status from a PC or GOT connected to the network.
Dual-loop fiber optical connection for high reliability
Redundant system using CC-Link IE for superior reliability
Acid cleaning Cold rolling Plating CoatingWashing Exposure Inspection Etching Peeling Liquid crystalfilling / assembly
Steel production process
Upper level PC Database server
Collect traceability dataSend recipe data
The maximum number of link registers per station has been increased 8 fold!Transfer large amounts of recipe or other data in a single link scan!
16 K words 128 K words
The network provides more than enough bandwidth to view the real-time status of each station from any point and collect large amounts of traceability data.
1Gbps
1Gbps
Tracking cable
NEW
Liquid-crystal production process
Super high speed A 1 Gigabit per second communication speed allows data to be transferred between controllers quickly.
Large capacity
Stable timingCyclic communication bandwidth is fixed and will not suffer from degraded performance even when transient communications are saturated.
Every link scan, the bandwidth available for cyclic communication can share 16 K physical I/O signals, 32 K bit registers, and 128 K words of register data. Add to that the bandwidth available for transient communication, and it is more than enough for recipe information and traceability data.
Large capacity
Large scale
Highly reliable Create a highly reliable system using redundant CPUs, a dual-loop optical network, and external power supplies.
Station-to-station distance up to 15 km using media converters (550 m using standard cable). Up to 120 stations per network. Maximum total distance using standard cable: 66 km Maximum number of networks: 239
Transfer 16 K physical I/O signals, 32 K bit registers, and 128 K words of register data via cyclic communication every link scan. Add to that the bandwidth available for transient communication, and it is more than enough for recipe information and traceability data.
*1
*1) To perform diagnostics or configure a network that uses more than 16 K link points per station, please use GX Works2 (Version 1.31H or later).
47 48
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
CC-Link IE Controller Network Modules for MELSEC-Q Series
QJ71GP21-SX / QJ71GP21S-SX
CC-Link IE Controller Network Communication Unit for GOT1000 Series
GT15-J71GP23-SX*2
CC-Link IE Controller Network PC Interface Board
Q80BD-J71GP21-SX*3 / Q80BD-J71GP21S-SX*3
Compact PCI (cPCI) compatible Interface Board
ECP-CLECBD / ECP-CLECBDS
Features
¡Use the same module as a control station or normal station (configure via parameters).
¡Choose the module with the external power supply function (QJ71GB21S-SX) to maintain communication even if power from the base unit is lost.
¡Several special instructions are available to easily perform transient communications via sequence program.
¡The network can ensure 32bit data integrity using the station-based block data assurance function.
¡The maximum link points per station has been increased to 128 K words using 'extended mode'. *1
Features
¡Connect Mitsubishi Graphic Operator Terminals directly to the CC-Link IE Controller Network.
¡Functions as a normal station on the CC-Link IE Controller Network.
Features
¡Using these PCI/PCI-X interface boards, PC control systems can be directly connected to the CC-Link IE Controller Network.
¡Can operate as the control station or a normal station.¡Choose the interface board with the external power supply function
(Q80BD-J71GP21S-SX) to maintain communication even if power from the PCI interface is lost.
This reference manual (used to develop hardware drivers) is provided for customers who wish to use the CC-Link IE Controller Network interface board with an operating system other than Windows®. This reference manual contains the following information that is required for driver development.¡Hardware information (PCI configuration, dual-port
memory, I/O port memory map)¡Software information (Initial setting and parameter
setting procedures for the driver)¡Sample code in C language with documentation
(on the included CD-ROM)
Features
¡Using these Compact PCI bus interface boards, PC control systems can be directly connected to the CC-Link IE Controller Network.
¡Can operate as the control station or a normal station.¡Choose the interface board with the external power supply function
(ECP-CLECBDS) to maintain communication even if power from the cPCI interface is lost.
Compliant model ...............................................................................GT15, GT16
nDocument (Reference Manual)Product Manual number Inquiries
Driver Development Reference Manual for CC-Link IE Q80BD-J71GP21-SX SH(NA)-080819ENG
Open System Center, Mitsubishi Electric Corporation, Nagoya WorksTEL: 052-712-2369 FAX: 052-712-2419E-mail: [email protected]
Operating environment for PC board
Produced by Mitsubishi Electric Engineering
External power supply function type
External power supply function type
Standard type
Standard type
External power supply function type
Product lineup
Standard type
Reference manual for the development of the interface board driver for PC
Available soon
*2) Not compatible with Extended mode.
*1) Support for expansion mode requires the following modules. QJ71GP21-SX / QJ71GP21S-SX whose first five serial number digits are 12052 or later. Universal model QCPU whose first five serial number digits are 12052 or later.
*3) Extended mode is supported by interface boards whose first five serial number digits are 12052 or later.
Operating environment for PC/Industrial computerItem Q80BD-J71GP21-SX / Q80BD-J71GP21S-SX ECP-CLECBD / ECP-CLECBDS
PCindustrial computer
Windows® supported personal computer(PC)
CPU Pentium®3 1GHz or higher
Required memoryWindows® 7 : 1GB or moreWindows Vista®, Windows Server® : 512MB or moreWindows® XP, Windows® 2000 : 256MB or more
Windows® XP Home Edition, Windows® XP Professional®,Windows® 2000 Professional : 256MB or more
Slot PCI bus slot (Half size)PCI-X bus slot (Half size) CompactPCI bus slot (3U size)
PCI busPCI bus standard Rev.2.2 or later(5V or 3.3 V DC: Universal PCI compliance)PCI-X bus standard 1.0 or later
Compatible with Compact PCI PICMG 2.0 Rev 3.0 (5V or 3.3 V DC: Universal PCI compliance)
Operating system(English Version)*1*2
Microsoft® Windows® 7 Home Premium Microsoft® Windows® 7 Professional Microsoft® Windows® 7 Ultimate Microsoft® Windows® 7 Enterprise Microsoft® Windows Vista® Home Basic Microsoft® Windows Vista® Home Premium Microsoft® Windows Vista® Business Microsoft® Windows Vista® Ultimate Microsoft® Windows Vista® Enterprise Microsoft® Windows Server® 2003 R2 (Service Pack 2 or later) Microsoft® Windows Server® 2008 Microsoft® Windows® XP Home Edition (Service Pack 2 or later)Microsoft® Windows® XP Professional (Service Pack 2 or later) Microsoft® Windows® 2000 Professional (Service Pack 4 or later)
Microsoft® Windows® XP Home Edition (Service Pack 2 or later)Microsoft® Windows® XP Professional (Service Pack 2 or later)Microsoft® Windows® 2000 Professional (Service Pack 4 or later)
Display Resolution: 1024 768 dots or higher
Hard disk space 80MB or more
Disk drive CD-ROM disk drive
Programming language(English Version)*1
Microsoft® Visual Basic® 6.0Microsoft® Visual Basic® .NET 2003Microsoft® Visual Studio 2005 Visual Basic®
Microsoft® Visual Studio 2008 Visual Basic®
Microsoft® Visual Basic® 6.0Microsoft® Visual Basic®.NET 2003Microsoft® Visual Studio 2005 Visual Basic®
Microsoft® Visual C++® 6.0Microsoft® Visual C++®.NET 2003Microsoft® Visual Studio 2005 Visual C++®
Microsoft® Visual Studio 2008 Visual C++®
Microsoft® Visual C++® 6.0Microsoft® Visual C++®.NET 2003Microsoft® Visual Studio® 2005 Visual C++®
*1) User programs created in the English environment work only in the English environment. *2) 64-bit version is not supported.
Application
Driver (to be developed)
OS other than Windows®
CC-Link IE ControllerNetwork interface board
Q80BD-J71GP21-SX
49 50
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Product Model Specifications
Splice adapter for LCF Connector SPAD-LCF-G50 Splice adapter for LCF connector Multimode 2 coresConnection loss: 0.3 dB (with master fiber)
Splice adapter for SC Connector SPAD-SC-G50 Splice adapter for SC connector Multimode 2 coresConnection loss: 0.3 dB (with master fiber)
Splice adapter for FC Connector SPAD-FC-G50 Splice adapter for FC connector Multimode 1 coreConnection loss: 0.3 dB (with master fiber)
Optical media converter
DMC-1000SL
Connection terminal
SC-ECT-P3Splice adapter
SPAD-LCF-G50/SPAD-SC-G50/SPAD-FC-G50
Connector insertion tool
SCT-SLM
Features
¡If more than the maximum segment length of 550 m is required, two of these units can be used to extend the total station to station distance to over 15 km.
Application example
Features
¡Add up to three stations in between existing stations.¡Stations can easily be added or removed.¡Allow for expansion of the network without having to change the existing
cabling.¡Can be mounted by DIN rail or screw bracket.
Power supply specificationsItem Rated DC power supply Rated AC power supply (AC adapter)
Rated input voltage DC3.3V AC100 to 120V
Current consumption 1.5A or less –
Rated input frequency – 50/60Hz
Range of voltage DC3.2 to 3.6V AC90 to 132V
Power consumption (at DC) 5.0W or less –
Apparent power – 11VA or less
Performance specificationsItem Port dedicated to single-mode optical
fiber cable (OPT1 port)Port dedicated to multi-mode optical
fiber cable (OPT2 port)
Conforming standard
IEEE802.3z Gigabit Ethernet (1000BASE-LX)
IEEE802.3z Gigabit Ethernet (1000BASE-SX)
Transmission method Full duplex method
Applicable optical fiber
1000BASE-LX compatible single-mode optical fiber cable
1000BASE-SX compatible multi-mode optical fiber cable
(Band: 500 MHz∙km or higher, l = 850 nm)
Interface 1 out connector port/1 in connector port (2 ports in total)
Applicable connector Duplex LC connector (IEC61754-20) Duplex SC connector (IEC61754-4)*1
Polishing method of connector PC, SPC, AdPC, UPC polish PC polish
Luminescence center wavelength 1270 to 1360nm 820 to 860nm
Allowable light loss 0 to 10dB 0 to 7.5dB
Target transmission distance 2m to 15km*2 550 m (max.)
*1) Use an optical fiber cable with a single-end duplex LC connector or a single-end duplex SC connector to connect the converter to CC-Link IE Control Network products.
*2) This is the target when the same models are connected. The target distance is 5 km when this model is connected to another unit compatible with 1000 BASE-LX.
SpecificationsItem Specifications
Applicable optical fiber
1000 BASE-SX (MMF)-compatible optical fiber cable
Standard IEC60793-2-10TypesA1a.1(50/125μmmultimode)
Transmission loss (max.) 3.5 (dB/km) or less (l = 850 nm)
Transmission band (min.) 500 (MHz∙km) or higher (l = 850 nm)
Model QG Series*2
Applicable light connector
Duplex LC connector
Standard IEC61754-20: Type LC connector
Connection loss 0.3 (dB) or less
Polished face PC polish
Model DLCF-G50-D2*2
Number of possible connections Max. 3 units
Operable environment In board
Operable temperature/humidity range 0°C to +55°C / 5 to 95% RH (no condensation)
Connection distance Max. 150 m*3
Installation Screw or DIN rail
Weight Approx. 300 g
External dimensions W151 5 D64 5 H65 (mm)
*1) At least one unit should be connected to the connection terminal.*2) Parts provided by Mitsubishi Electric System & Service. *3) Cable length from the SC-ECT-P3 to any other connection point
Optical fiber cable
QG-AW/QG-B/QG-C/QG-DL
Cables and accessories
Features
¡These optical fiber cables are recommended by the CC-Link Partner Association.¡Several different types of cable are available. These include types for use
inside panels, indoors, outdoors, and a reinforced type for outdoor use allowing placement in a variety environments.
¡The newly developed thin cable (for indoor and outdoor use) incorporates a cord bundling structure, allowing safe use even in confined factory cable-conduits.
¡The indoor and outdoor use cables are free of tension members, and have an allowable tension equivalent to the reinforced type for outdoor use that allows them to be pulled directly.
¡The outdoor use cable is waterproof, and can be used even in flooded or temporarily submerged areas.
¡By attaching the enclosed protective holder, the cable connector base is protected and control panel space can be saved.
¡A connector boot with improved bending characteristics reduces the possibility of fiber breakage at the connector base.
[ Features ]
¡Protects the cable connector base prevents breakage¡Maintains minimum bending radius¡Saves space in control panel (60 mm or less from front of PLC to end of
protective holder)
*1) The protective holder is unique to the Mitsubishi Electric System Service Co., Ltd. LCF connector and is not available as a single unit. It cannot be used with other LCF connector brands.
Standard accessories: Protective holder*1 (One protective holder is enclosed per cable.)
LCF connectorDuplex LC connector (IEC61754-20)
SPAD-LCF-G50
Produced by Mitsubishi Electric System & Service
Produced by Mitsubishi Electric System & Service
Produced by Mitsubishi Electric System & Service
Produced by Mitsubishi Electric System & Service
Produced by Mitsubishi Electric System & Service
Features
¡Extends optical fiber cable (Splice connection)¡Temporary connection for stations which may be extended later
Features
¡Insert or remove connectors easily, even in tight spaces such as crowded control panels.
Applicable connector
¡LCF/LC/SC/MU connector
Multimode opticalfiber cable
(up to 550m)
Single modeoptical fiber cable
(up to 15km)
Single modeoptical fiber cable
(up to 15km)
Factory A Factory B
Factory C
Media converter Media converter
Media converterMedia converter
Communication configuration example
SC-ECT-P3*1
Additional stations
* The solid black lines represent cables with a maximum distance of 150 meters. If any station goes down, the loop back function will still be operational.
Applicable connector
51 52
CC
-Link IE F
ieldC
C-Link IE
contro
lList o
f com
patib
le pro
ducts
Item Specifications
Maximum link points per network
LB 32 K points (32768 points, 4 Kbytes) (Basic model QCPU, Safety CPU: 16 K points (16384 points, 2 Kbytes))
LW 128K K points (131072 points, 256 Kbytes) (Basic model QCPU, Safety CPU: 16 K points (16384 points, 32K Kbytes))
LX 8 K points (8192 points, 1 Kbyte)
LY 8 K points (8192 points, 1 Kbyte)
Maximum link points per station
Regular mode Expansion mode*1
LB 16 K points (16384 points, 2 Kbytes) 32 K points (32768 points, 4 Kbytes)
LW 16 K points (16384 points, 32 Kbytes) 128 K points (131072 points, 256 Kbytes)
LX 8 K points (8192 points, 1 Kbytes) 8 K points (8192 points, 1 Kbytes)
LY 8 K points (8192 points, 1 Kbytes) 8 K points (8192 points, 1 Kbytes)
Communication speed 1Gbps
Maximum stations per network 120 (1 control station plus 119 normal stations)
Connection cable Multi-mode fiber optical cable
Overall cable distance 66000 m (When 120 stations are connected)
Station-to-station distance (max.) 550m(core/clad=50/125μm)
Maximum number of networks 239
Maximum number of groups 32
Network topology Duplex loop ring
*1)Expansion mode requires the following modules and software. CC-Link IE Controller network modules (QJ71GP21-SX / QJ71GP21S-SX) whose first five serial number digits are 12052 or later. Universal model QCPU whose first five serial number digits are 12052 or later. GX Works2 Version 1.40S or later. Also, all stations must be compatible with expansion mode.
Item Specifications
Optical fiber specifications*1
1000BASE-SX (MMF) fiber optical cable
Standard IEC60793-2-10TypesA1a.1(50/125μmmultimode)
Transmission loss (max.) 3.5 (dB/km) or less (l = 850 nm)
Transmission band (min.) 500 (MHz∙km) or higher (l = 850 nm)
Connector specifications*1
Duplex LC connector
Standard IEC61754-20: Type LC connector
Connection loss 0.3 (dB) or less
Polished face PC (Physical Contact) polishing
*1) For recommended cables and other information, contact the CC-Link Partner Association.
Performance specifications
Cable specifications
Network topology example
Ring topology
General specifications
Item Specifications
Operable ambient temperature 0 to 55°C
Storage ambient temperature −25 to 75°C*1
Operable ambient humidity 5 to 95% RH*2, no condensation
Storage ambient humidity 5 to 95% RH*2, no condensation
Vibration resistance Compatible with JIS B 3502, IEC 61131-2
Frequency Constant acceleration Half amplitude Number of sweeps
With intermittent vibrations
5 to 9Hz – 3.5mm 10 times in each of the X. Y, and Z directions9 to 150Hz 9.8m/s2 –
With continuous vibrations
5 to 9Hz – 1.75mm–
9 to 150Hz 4.9m/s2 –
Shock resistance Compatible with JIS B 3502, IEC 61131-2 (147 m/s2, 3 times in each of the X, Y, and Z directions)
Operable ambient conditions No corrosive gas
Operable altitude*3 2000 m or lower
Installation place Inside the control box
Over voltage category *4 @or lower
Pollution degree *5 2 or lower
Device class Class!
*1) The allowable ambient storage temperature is −20 to 75°C when an AnS/A Series unit is included in the system.*2) The operable ambient humidity and storage ambient humidity are 10 to 90% RH when an AnS/A Series unit is included in the system.*3) Do not use or store your PLC in any place where the ambient atmospheric pressure exceeds 1 atm (atmospheric pressure at sea level). Contact your local Mitsubishi Electric representative if you wish to operate the PLC under such conditions, as malfunctions could occur.*4) Assigned based on where the equipment is connected relative to the public power distribution network as defined in IEC60664. Category @ is applicable to equipment to which power is supplied from some fixed facility. As defined by the IEC, equipment with a rated voltage of 300 V or lower must be surge-resistant up to 2500 V.*5) This index specifies the worst environmental conditions the equipment is designed to function in.
Pollution degree 2 specifies that the operating environment may only contain non-conductive materials, however occasional temporary conductivity caused by condensation must be expected.
The general specifications are applicable to all products in the Q Series and L Series unless an exception is indicated. The Q Series and L Series equipment is designed to be installed and operate within the environment specified by the general specifications. For the general specifications of products provided by other manufacturers, contact the relevant manufacturer or distributer.The general specifications of jointly developed products may be different.For more information, please refer to the product manuals or contact your local Mitsubishi representative for details.
Overall cable distance: max. 66,000 m
Controlstation
Normalstation
Normalstation
Normalstation
Station-to-station distance:max. 550 m
53 54
Produced by Mitsubishi Electric CorporationProduct Model Outline
CC-Link IE Field Network Master/Local Unit QJ71GF11-T2*1 For master/local station in CC-Link IE Field Network for MELSEC-Q Series
CC-Link IE Field Network Head Unit LJ72GF15-T2*1 Head Unit compatible with MELSEC-L Series (with END cover) for MELSEC-L Series
CC-Link IE Field Network PC Interface Board Q81BD-J71GF11-T2SOON
Compatible with PCI Express bus For control station/normal station of CC-Link IE Field Network
CC-Link IE Field Network Ethernet Adapter module
NZ2GF-ETB*1
NEWCompatible with transmission rates of 100Mbps/1GbpsFor CC-Link IE Field Network extension station
Industrial switching hubNZ2EHG-T8*2 DB Compatible with NZ2EHG-T8 10Mbps/100Mbps/1Gbps AUTO-MDIX DIN rail, 8 ports
NZ2EHF-T8*2
NEW DB 10Mbps/100Mbps AUTO-MDIX DIN rail, 8 ports
*1) GX Works2 required to make settings and to conduct diagnosis of the CC-Link IE Field Network.*2) This series was developed and is produced with Contec Co. Ltd. Please note that the specifications and the guarantee conditions of this series are different from those of MELSEC and Contec Co. Ltd. For more information, refer to each manual or please contact your local Mitsubishi representative for details.
List of compatible products
For CC-Link IE Field Network Head ModuleProduct Model Outline
I/O module
Input
DC(Positive or negative common)
LX40C6 16 points 24VDC Response times: 1/5/10/20/70 ms 16 points/1commonPositive/Negative common 18-point terminal block
LX41C4 32 points 24VDC Response times: 1/5/10/20/70 ms 32 points/1commonPositive/Negative common 40-pin connector
LX42C4 64 points 24VDC Response times: 1/5/10/20/70 ms 32 points/1common Positive/Negative common, 40-pin connector x 2
Output
Relay LY10R2 16 points 24VDC / 240VAC 2A/1 point 8A/1common Response time: 10 ms 16 points/1common 18-point terminal block
Transistor(Sink)
LY40NT5P NEW 16 points 12 to 24VDC 0.5A/point 5A/common Response time: 0.5ms 16 points/common 18-point terminal block overload protection function overheat protection function surge suppression
LY41NT1P 32 points 12 to 24VDC 0.1A/point 2A/common Response time: 0.5ms 32 points/common Sink type 40-pin connector overload protection function overheat protection function surge suppression
LY42NT1P 64 points 12 to 24VDC 0.1A/point 2A/common Response time: 0.5ms 32 points/common Sink type 40-pin connector x 2 overload protection function overheat protection function surge suppression
Transistor(Source)
LY40PT5P NEW 16 points 12 to 24VDC 0.5A/point 5A/common Response time: 0.5ms 16 points/common 18-point terminal block overload protection function overheat protection function surge suppression
LY41PT1P NEW 32 points 12 to 24VDC 0.1A/point 2A/common Response time: 0.5ms 32 points/common 40-pin connector overload protection function overheat protection function surge suppression
LY42PT1P NEW 64 points 12 to 24VDC 0.1A/point 2A/common Response time: 0.5ms 32 points/common 40-pin connector x 2 overload protection function overheat protection function surge suppression
Intelligent function module
Analog input L60AD4 4 channels Input: −10 to 10VDC 0 to 20mADC Output (resolution): 0 to 20000 −20000to20000Conversionspeed:20μs80μs1ms/ch18-pointterminalblock
Analog output L60DA4 4 channels Input (resolution): 0 to 20000 −20000 to 20000 Output: -10 to 10VDC 0to20mADCConversionspeed:20μs/ch18-pointterminalblock
Simple motion*3LD77MH4 4 axes 2-/3-/4-axis linear interpolation 2-axis circular interpolation synchronous control
Control unit: mm inch degree pulse Number of positioning data: 600 data/axis SSCNET 3 connectivity
LD77MH16 NEW 16 axes 2-/3-/4-axis linear interpolation 2-axis circular interpolation synchronous control Control unit: mm inch degree pulse Number of positioning data: 600 data/axis SSCNET 3 connectivity
Positioning*3LD75P4 4 axes 2-/3-/4-axis linear interpolation 2-axis circular interpolation Control unit: mm inch degree pulse
Number of positioning data: 600 data/axis Maximum output pulse: 200kpps 40-pin connector x2
LD75D4 4 axes 2-/3-/4-axis linear interpolation 2-axis circular interpolation Control unit: mm inch degree pulse Number of positioning data: 600/axis Maximum output pulse: 4Mpps 40-pin connector x2
High-speed counter
LD62 2 channels 200/100/10 kpps Count input signal: 5/12/24VDC External input: 5/12/24VDC Coincidence output: transistor (sink) 12/24VDC 0.5A/1point 2A/1common 40-pin connector
LD62D2 channels 500/200/100/10 kpps Count input signal: EIA standard RS-422-A (Differential line driver level) External input: 5/12/24VDC Coincidence output: transistor (sink) 12/24 VDC 0.5A/1point 2A/1common 40-pin connector
Serial communicationLJ71C24 RS-232: 1 channel, RS-422/485: 1 channel, Total transmission speed of 2 channels: 230.4kbps
LJ71C24-R2 RS-232: 2 channels, Total transmission speed of 2 channels: 230.4kbps
Network CC-Link LJ61BT11 Master/Local station, CC-Link Ver.2.0 compatible
Power supplyL61P Input voltage: 100 to 240VAC Output voltage: 5VDC Output current: 5A
L63P Input voltage: 24VAC Output voltage: 5VDC Output current: 5A
Option End cover with error terminal L6EC-ET END cover with error terminal
*3) Simple motion and positioning modules are supported by CC-Link IE Field head modules (LJ72GF15-T2) whose first five serial number digits are 12072 or later.
CC-Link IE Field NetworkProduced by Mitsubishi Electric Corporation
Product Model Outline
CC-Link IE Controller Network Unit
QJ71GP21-SX For control station/normal station of CC-Link IE Controller Networkfor MELSEC-Q Series
QJ71GP21S-SXFor control station/normal station of CC-Link IE Controller NetworkWith external power supply functionfor MELSEC-Q Series
CC-Link IE Controller Network Communication Unit GT15-J71GP23-SX
CC-Link IE Controller Network Communication Unit compatible with GT15, GT16For CC-Link IE Controller Network Normal Station for GOT1000 Series
Interface Board for CC-Link IE Controller Network PC
Q80BD-J71GP21-SX Compatible with PCI bus/PCI-X busFor control station/normal station of CC-Link IE Controller Network
Q80BD-J71GP21S-SXCompatible with PCI bus/PCI-X busFor control station/normal station of CC-Link IE Controller NetworkWith external power supply function
Produced by Mitsubishi Electric System & ServiceProduct Model Outline
Cables and accessories
Optical fiber cable compatible with CC-Link IE Controller Network
QG-AW Optical fiber cable compatible with CC-Link IE Controller Network (in the control board)
QG-B Optical fiber cable compatible with CC-Link IE Controller Network (indoor)
QG-C Optical fiber cable compatible with CC-Link IE Controller Network (outdoor)
QG-DL Optical fiber cable compatible with CC-Link IE Controller Network (reinforced outdoor)
Option
SPAD-LCF-G50 Splice adapter for LCF connector Multimode 2 cores Connection loss: 0.3 dB (with master fiber)
SPAD-SC-G50 Splice adapter for SC connector Multimode 2 cores Connection loss: 0.3 dB (with master fiber)
SPAD-FC-G50 Splice adapter for FC connector Multimode 1 core Connection loss: 0.3 dB (with master fiber)
SCT-SLM Connector insertion tool (applicable connector: LCF connector, LC connector, SC connector, MU connector)
Optical media converter DMC-1000SL Optical media converter compatible with CC-Link IE Controller Network
Connection terminal SC-ECT-P3 Cable bundling device compatible with CC-Link IE Controller Network
For details of Mitsubishi Electric System & Service Co., Ltd. products,contact us by sending an e-mail to the following address.<Sales office> FA PRODUCT DIVISION mail:[email protected]
Produced by Mitsubishi Electric EngineeringProduct Model Outline
CC-Link IE Controller Network Interface Board compatible with Compact PCI
ECP-CLECBD SOONFor control station/normal station of CC-Link IE Controller Network compatible with Compact PCI bus Japanese/English OS
ECP-CLECBDS SOONFor control station/normal station of CC-Link IE Controller Network compatible with Compact PCI bus Japanese/English OSWith external power supply function
CC-Link IE Controller Network[ Legend ] DB : Double brand product (Note) NEW : Recently released product SOON : Product available soon
Produced by Mitsubishi Electric System & ServiceProduct Model Outline
Cable and accessoryEthernet cable SC-E5EW Series (Double shielded/STP) Straight cable
Option SPAD-RJ45S-E5E RJ45 (8P8C) with shield
For details of Mitsubishi Electric System & Service Co., Ltd. products,contact us by sending an e-mail to the following address.<Sales office> FA PRODUCT DIVISION mail:[email protected]
[ Legend ] DB : Double brand product (Note) NEW : Recently released product SOON : Product available soon
Note: General specifications and product guarantee conditions of jointly developed products are different from those of MELSEC products. For more information, please refer to the product manuals or contact your local Mitsubishi representative for details.
CC
-Link IE C
ontro
lC
C-Link IE
Field
List of co
mp
atible p
rod
ucts
55 56
Comparison of network specificationsMELSECNET/H
CC-LinkOptical loop type
Coaxial bus type
Twist bustype
Communication speed (bps) 1G 25M 10M 10 M (max.) 1G 10 M (max.)
Maximum number of link words (LW)
per network 128K 16K 8K*2 2K*2
per station 128K*1 16K 1K*2 128*2
(with 4 stations)
Maximum number of connected stations per network
120 64 32 32 121 65
Distance
Total extension distance (km) 66 30 2.5*3 0.1
(10 Mbps) 12 1.1*3
(10 Mbps)
Maximum station-to-station distance (m)
550 1000 500 100(10 Mbps) 100 100
(10 Mbps)
Wiring
Topology Ring Ring Bus Bus Star, line, star and line mixed, or ring Bus, T-branch, or star
Cable General-purpose Ethernet cable (multimode optical fiber) Optic cable Coaxial cable Twisted cable General-purpose Ethernet cable
(Category 5e or better)Twisted cable
(CC-Link-dedicated cable)
*1) To perform diagnostics or configure a network that uses more than 16 K link points per station, please use GX Works2 (Version 1.31H or later).*2) Maximum number of link points (RWw).*3) When using repeater.
Related product catalogs
Open Field Network CC-Link Compatible Product CatalogL(NA)08038E
Open Field Network CC-Link, CC-Link/LT Compatible Product Development GuidebookL(NA)08052E
Mitsubishi iQ Platform Programmable Controller MELSEC-Q Series [QnU]L(NA)08101E
Programmable Controllers MELSEC-L SeriesL(NA)08159E
Servo System Network SSCNET 3L(NA)03022
Mitsubishi Graphic Operation Terminal GOT1000L(NA)08054
CC-Link + Industrial Ethernet =The Field Network Revolution BeginsCC-L ink IE Field Network
Debut!
2010 Sep
.
To use the products given in this publication properly, always read the relevant manuals before use.The products have been manufactured as general-purpose parts for general industries, and have not been designed or manufactured to be incorporated in a device or system used in purposes related to human life.Before using the products for special purposes such as nuclear power, electric power, aerospace, medicine or passenger movement vehicles, consult with Mitsubishi.The products have been manufactured under strict quality control. However, when installing the products where major accidents or losses could occur if the products fail, install appropriate backup or fail-safe functions in the system.
This publication explains the typical features and functions of the products herein and does not provide restrictions and other information related to usage and module combinations. Before using the products, always read the product user manuals.Mitsubishi Electric will not be held liable for damage caused by factors found not to be the cause of Mitsubishi Electric; opportunity loss or lost profits caused by faults in Mitsubishi Electric products; damage, secondary damage, or accident compensation, whether foreseeable or not, caused by special factors; damage to products other than Mitsubishi Electric products; and to other duties.
Precautions before use Ethernet-based Open NetworkCC-Link IE Product Catalog
Ethernet-based Open NetworkCC-Link IE Product Catalog
L(NA)08111E-D 1102(MDOC)New publication as of Feb. 2011
Specifications subject to change without notice.