64
© 2015 Eaton, All Rights Reserved. CEAG Emergency Lighting Solutions www.ceag.de/en

CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

Embed Size (px)

Citation preview

Page 1: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

© 2015 Eaton, All Rights Reserved.

CEAG Emergency Lighting Solutions

www.ceag.de/en

Page 2: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

2 © 2015 Eaton, All Rights Reserved.

• History

• About CEAG

• Portfolio

• Main Markets

• Environmental commitment

• Product Development

• The Eaton Philosophy

• Products & Technologies

• References

Agenda

Page 3: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

3 © 2015 Eaton, All Rights Reserved.

CEAG History

1906

Company founded in

Cologne. Production of

lamps for use in coal

mines.

CEAG awarded prize for

the “safest mining lamp

in the world”.

1952

Production of explosion-protected

light fittings in Bochum to meet

the new market requirements.

1970

A further step on the path to

success: launch of emergency

lighting systems.

CEAG acquired by BBC AG,

Mannheim. Explosion

protected installation material

completes the explosion

protection field.

1988

As a company operating

independently within the ABB

Corporation, CEAG is part of a

strong group of companies and

is well-armed for the future.

1996

CEAG Group acquired by

Cooper Industries.

Emergency lighting

business of CEAG

established as “CEAG

Notlichtsysteme GmbH”.

2012

Cooper Industries acquired

by Eaton – new

opportunities for CEAG.

1912

1978

2003

Page 4: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

4 © 2015 Eaton, All Rights Reserved.

About CEAG (CEAG Notlichtsysteme GmbH)

Expertise and Technology you can trust

• Founded in Cologne 1906

• Site is located in Soest, Germany

• One of the “Top Ten” employers in Soest

• Number of employees: 230 Soest

Page 5: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

5 © 2015 Eaton, All Rights Reserved.

CEAG Portfolio

Safety Luminaires and

Escape Sign Luminaires

Central Battery

Systems

Visualization &

Networks

Page 6: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

6 © 2015 Eaton, All Rights Reserved.

CEAG Main Markets

• Airports

• Restaurants

• Hotels & High-rise

Buildings

• Shopping Malls &

Retail Shops

• Sport Stadia

• Logistic Centers

• Railway Stations &

Ports

• Government Buildings

• Schools

• Colleges & Universities

• Health Centers

• Hospitals

• Theatres

• Galleries & Museums

• Refineries

• Pharmaceutical

Industry

• Automobile Industry

• Light and Heavy

Industry

• Energy Supplier

• Food Industry

• Aerospace Industry

Airport Dubai

Public Buildings Commercial Industrial

Castle Bellevue, Berlin BP Refinery, Gelsenkirchen

Page 7: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

7 © 2015 Eaton, All Rights Reserved.

Application-optimised

Lower installation costs

Energy-efficient

Low operating costs

Cost-efficient

Optimised investment costs

Environmentally friendly

Low consumption of

raw materials

Environmental Commitment

Perfect combination of ecological responsibility with high cost-efficiency.

Page 8: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

8 © 2015 Eaton, All Rights Reserved.

CEAG Product Development

• New and further development

• Innovative contemporary design and

technologies

• Lighting Laboratory

• Customers light engineering

requirements at in-house lighting

laboratory

• Endurance Testing

• Expose newly developed products

to extreme conditions and life cycle

testing

Page 9: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

9 © 2015 Eaton, All Rights Reserved.

Certifications

• Certification of ISO 9001 : 2008

Benefits for our customer:

• Certainty of Eaton‘s commitment to

deliver high quality for all products and

all employees

• Certification of our products

• ENEC

• CNBOP

Page 10: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

10 © 2015 Eaton, All Rights Reserved.

The Eaton Philosophy

• Obeying the law

• Integrity of recording and reporting

our financial results

• Respecting human rights

• Delivering quality

• Competing ethically

• Respecting diversity and fair employment practices

• Avoiding conflicts of interest

• Protecting assets and information

• Acting with integrity

• Selling to governments while complying with special laws

• No political contributions

• Environment, health and safety

Page 11: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

11 © 2015 Eaton, All Rights Reserved.

Each Safety Luminaire is important –

it protects human´s life & health.

Page 12: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

12 © 2015 Eaton, All Rights Reserved.

MAINS LIGHTING

Page 13: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

13 © 2015 Eaton, All Rights Reserved.

Verschiedene Installationsvarianten 13

BLACKOUT

Page 14: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

14 © 2015 Eaton, All Rights Reserved.

Exit sign

BLACKOUT

Page 15: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

15 © 2015 Eaton, All Rights Reserved.

BLACKOUT

Safety luminaires

Page 16: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

16 © 2015 Eaton, All Rights Reserved.

Emergency Lighting Technologies

Central

battery

System

luminaires

Battery

included

Self-Contained Luminaires (SC)

Central Battery Systems (CBS)

System

luminaires

AC safety

power source

AC monitoring systems

Visualization

Page 17: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

17 © 2015 Eaton, All Rights Reserved.

Emergency Lighting Costs

Page 18: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

18 © 2015 Eaton, All Rights Reserved.

Central Battery System Installation

Page 19: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

19 © 2015 Eaton, All Rights Reserved.

Free programmability of switching

mode of each individual luminaire

per circuit without additional data

Line.

Individual single luminaire

monitoring of up to 20 luminaires

per circuit without additional data

line.

Central monitoring and control of

self-contained luminaires including

automatic function- and duration

test.

All well-proven advantages of the

STAR and CG Technology, now

available for AC safety power

sources.

Comfortable visualization software

which allows the configuration and

monitoring of all CEAG systems.

CEAG Technologies

Page 20: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

20 © 2015 Eaton, All Rights Reserved.

CEWA GUARD Technology

Our Philosophy:

Every safety luminaire is important. It protects health and life.

• Shortened

inspection effort

• Shortened

maintenance effort

• High safety level

Page 21: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

21 © 2015 Eaton, All Rights Reserved.

CEWA GUARD Technology

General

energy grid

General

Lighting

Change-

Over Unit

Battery DALI

Controller

DALI Bus

DALI EVG gDL gDL

1.7

DL

1.9

DL

1.3

DL

1.1

DL

1.4

BL

1.2

gDL

1.5

gDL

1.6

BL

1.10

BL

1.11

gDL

1.20

DL

Charger

1.12

BL

DLS / 3PH

General

Lighting

1.8

gDL

CBS

Central

Unit

Info:

Luminaire

failure

Page 22: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

22 © 2015 Eaton, All Rights Reserved.

CEWA GUARD Technology

CEWA GUARD (CG): The basis for a convenient maintenance and inspection of

centrally supplied systems

When an emergency lighting system is put into operation, it is in perfect condition. What, however,

counts more, is its reliable functioning in case of emergency, regardless of whether that happens

after4 weeks or 5 years. Maintenance, service and inspection are the prerequisite for that reliability.

That is, of course, expensive. Luminaires and batteries must be replaced. Apart from regular visual

checks, all luminaires must be submitted to function and duration Tests. Test data and system-

related information must be documented in a log book. CEAG emergency power supply systems

with CEWA GUARD functions considerably simplify maintenance, service and inspection and

thereby provide for a distinct reduction of costs.

CEWA GUARD is a self-testing and monitoring system. That means only one cable for:

• AC 230 V, 50/60 Hz power supply

• DC 220 V power supply

• data transmission

No additional shielded cables are required to operate the system. The short-circuit-proof L/N

connection provides for a safe and reliable functioning of the system. The backbone and brain of

the system is a microprocessor which controls and monitors all functions, stores any changes of

the status and passes information to an overriding monitoring and display system.

Page 23: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

23 © 2015 Eaton, All Rights Reserved.

STAR Technology

Different switching modes of each single

luminaires without additional data line!

• Easier planning

• Reduced installation expenditures

• Less cable lengths

Page 24: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

24 © 2015 Eaton, All Rights Reserved.

Conventional Installation

Page 25: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

25 © 2015 Eaton, All Rights Reserved.

STAR Technology

Different switching modes of each single luminaires without additional data line!

Page 26: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

26 © 2015 Eaton, All Rights Reserved.

STAR Technology

220V

Light switch for luminaire 3

0101000...1

Non-maintained light

Maintained light

Switched maintained

light

1

2

3

4

5

6

20

L N PE 230 V 50 Hz

0

Page 27: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

27 © 2015 Eaton, All Rights Reserved.

STAR Technology

220V

Light switch for luminaire 3

0111000...1

1

2

3

4

5

6

20

L N PE 230 V 50 Hz

0

Non-maintained light

Maintained light

Switched maintained

light

Page 28: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

28 © 2015 Eaton, All Rights Reserved.

STAR Technology

Switch to safety with the STAR (S) Technology!

The continuing development of the CEWA GUARD monitoring system has led to the creation of the

Switching Technology Advanced Revision, or “STAR” for short. This CG-STAR technology allows

different switching modes to be implemented in one and the same circuit, and the switching mode

of each individual luminaire can be re-programmed at any time.

As a result, this technology offers not just the proven CEWA Guard safety when it comes to

operating a safety lighting system, it also gives planners the confidence and flexibility of knowing

that the system can respond and adapt at any time to any changes that are made to a building and

its use.

Your Advantages

The number of outgoing circuits needed can be sharply reduced, since continuously operating,

stand-by and switchable permanent lighting can be realised in one common circuit.This allows the

use of shorter cable distances, reduces installation costs and minimises the effects of burning

materials. Any mode of operation can be assigned at a later date – without encroachment in the

lighting installation. This enables simple project planning without having to take all possible types

of operation into account.

As with CEWA GUARD technology, the STAR and STAR+ technology requires no additional data

cable to the luminaires .

Page 29: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

29 © 2015 Eaton, All Rights Reserved.

Central Battery System Components

System Luminaires

For Identification & Lighting of

Escape Routes

Explosion protected

Luminaires

Luminaires with Higher

Degree of Protection

LED Luminaires

Modules

For Integration of General Lighting within

Emergency Lighting

Monitoring Modules

LED Supply Modules

Electronic Ballasts

Page 30: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

30 © 2015 Eaton, All Rights Reserved.

Central Battery Systems

Low Power System

LP-STAR

Switchgears

Control & Electrical Power Supply of Safety Luminaires in Emergency

Central Power Supply System

ZB-S

ZB-S substation

US-S SOU1

ZB-S substation with

functional integrity ESF-E30

Page 31: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

31 © 2015 Eaton, All Rights Reserved.

Central overall

fire protection

section

installation

Advantages:

• One distributor for all

emergency light circuits

• Central distributor

maintenance and repair

Disadvantages:

• Increased complexity with

E30 cabling and revision

• Cable lengths limited due

to voltage drops

• Fireproof cable

Page 32: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

32 © 2015 Eaton, All Rights Reserved.

Decentral overall

fire protection

section

installation

Advantages:

• Partial reduction of costs

for E30 cabling

• Central maintenance and

repair of the distributor for

lower maintenance and

repair costs

Disadvantages:

• Increased complexity with

maintenance and repair

due to decentral

arrangement

• Further electrical service

rooms required if

necessary

• Fireproof cable

Page 33: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

33 © 2015 Eaton, All Rights Reserved.

Decentral overall

fire protection

section installation

with small

distribution boxes

Advantages:

• Reduction of costs for E30

cabling and revisions

• No additional electrical

service rooms, if permissible

Disadvantages:

• Complex planning, e.g. due

to selectivity

• Increased complexity with

maintenance and repair due

to decentral arrangement

Page 34: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

34 © 2015 Eaton, All Rights Reserved.

Decentral,

section-specific

fire protection

installation with

LP-STAR

Advantages:

• No costs for E30 cabling

and revisions

• Increased safety due to

decentral arrangement of

supply devices

Disadvantages:

• Increased complexity with

maintenance and repair

due to decentral

arrangement

Page 35: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

35 © 2015 Eaton, All Rights Reserved.

Decentral,

section-specific

fire protection

installation with

LP-STAR

Advantages:

• No costs for E30 cabling

and revisions

• Increased safety due to

decentral arrangement of

supply devices

Disadvantages:

• Increased complexity with

maintenance and repair

due to decentral

arrangement

Page 36: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

36 © 2015 Eaton, All Rights Reserved.

Free programmability of switching mode of

each individual luminaire per circuit without

additional data line

• easier planning

• reduced installation expenditures

• less cable lengths

Automatic monitoring of each single

luminaires without additional data line

• shortened inspection effort

• shortened maintenance effort

• high safety level

STAR+ Technology

1.1

1.2

1.3

1.20

2.1

2.2

2.3

2.20

for AC safety power sources.

Page 37: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

37 © 2015 Eaton, All Rights Reserved.

STAR+ Technology

STAR+: STAR Technology now available for AC Safety Power Sources

STAR+ offers all the known benefits of our STAR technology, now also for AC safety power

sources. It is the perfect symbiosis of CEWA GUARD and STAR technology.

With the help of the STAR+ technology the Automatic Test System AT-S+ individually monitors each

CG-S luminaire (up to 20 per circuit), and it does all this using the power supply cable alone.

The new STAR+ technology allows the switching mode of every connected V-CG-S luminaire to be

freely programmed within a 50 or 60 Hz supply network using the system‘s controller. This means

that maintained light, switched maintained light and non-maintained light modes can be combined

in one and the same circuit – there is no need for separate data cables!

Page 38: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

38 © 2015 Eaton, All Rights Reserved.

Automatic Luminaire Test System AT-S+

AT-S+ / SOU1

Switchgears

AT-S+ / SU1 AT-S+ / C30

Control of Emergency Luminaires

Page 39: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

39 © 2015 Eaton, All Rights Reserved.

Central overall

fire protection

section

installation

Advantages:

• One distributor for all

emergency light circuits

• Central distributor

maintenance and repair

• One electrical service

room for the distributor if

required

Disadvantages:

• Increased complexity with

E30 cabling and revision

• Cable lengths limited due

to voltage drops

• Fireproof cable

Page 40: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

40 © 2015 Eaton, All Rights Reserved.

Decentral overall

fire protection

section

installation

Advantages:

• Partial reduction of costs

for E30 cabling

• Central maintenance and

repair of the distributor for

lower maintenance and

repair costs

Disadvantages:

• Increased complexity with

maintenance and repair

due to decentral

arrangement

• Further electrical service

rooms required if

necessary

• Fireproof cable

Page 41: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

41 © 2015 Eaton, All Rights Reserved.

Decentral overall

fire protection

section installation

with small

distribution boxes

Advantages:

• Reduction of costs for E30

cabling and revisions

• No additional electrical

service rooms, if permissible

Disadvantages:

• Complex planning,

e.g. selectivity

• Increased complexity with

maintenance and repair due

to decentral arrangement

Page 42: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

42 © 2015 Eaton, All Rights Reserved.

Decentral overall

fire protection

section installation

with small

distribution boxes

Advantages:

• Reduction of costs for E30

cabling and revisions

• No additional electrical

service rooms, if permissible

Disadvantages:

• Complex planning,

e.g. selectivity

• Increased complexity with

maintenance and repair due

to decentral arrangement

Page 43: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

43 © 2015 Eaton, All Rights Reserved.

Self-Contained Luminaires System

• Central Monitoring Device

• Central Monitoring & Control of Self-Contained

Luminaires

• Self-Contained Luminaires

• Identification & Lighting of Escape Routes

1 2 3 200

1 2 3 200

1 2 3 200

1 2 3 200

Line 1

Line 2

Line 3

Line 4

Page 44: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

44 © 2015 Eaton, All Rights Reserved.

CGLine+ self-

contained

luminaire system

Advantages:

• No fireproof cables

• Decentral safety power

sources

• No additional service

room

Disadvantages:

• Additional effort for

maintenance and repair

due to decentral battery

arrangement

• Separate data line to

each single luminaire

• Life time of batteries: 4

years, influenced by

ambient temperatures

(max. 30° C)

Page 45: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

45 © 2015 Eaton, All Rights Reserved.

Visualization

CGVision:

A software to safe your time…

• Intuitive Operating Concept

• Configuration & programming of the

complete system

• Fully Automatic Process

• Weekly automatic test of each single

luminaire

• Graphical Display Possibilities

• Display of luminaires in layout plans

& concise display of location in aerial

views

Page 46: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

46 © 2015 Eaton, All Rights Reserved.

Visualization

Web-based Visualization…

Web-Module for visualization and

monitoring of your systems

• Actual operation

modes

• Localized failure

information

• Easy menu structure

Page 47: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

47 © 2015 Eaton, All Rights Reserved.

Our Strengths

• Expertise

• Over 40 years experience and

long term relationship with our

customers

• Innovation

• Newest technologies and energy

efficient systems

• Know- how

• Quality standards and access to

the world wide network of Eaton

Page 48: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

© 2015 Eaton, All Rights Reserved. 48

References

Page 49: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

49 © 2015 Eaton, All Rights Reserved.

Assembly Halls / Assembly Rooms

Castle Bellevue, Berlin

Grand Moshe, Abu Dhabi

Semper Opera, Dresden

German Bundestag, Berlin

Page 50: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

50 © 2015 Eaton, All Rights Reserved.

Assembly Halls / Assembly Rooms

Exhibition Centre, Leipzig National Theatre, Budapest

Exhibition Centre, Frankfurt National Convention Centre Doha, Qatar

Page 51: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

51 © 2015 Eaton, All Rights Reserved.

Sport & Olympic Venues

Niedersachsen Stadium,

Hannover

Fritz Walter Stadium,

Kaiserslautern

Karaiskaki Stadium,

Athens

Page 52: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

52 © 2015 Eaton, All Rights Reserved.

Sport & Olympic Venues

Watercube, Beijing Olympic Hockey Stadium, Athens

Spaladium Arena, Croatia Arena, Oberhausen

Page 53: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

53 © 2015 Eaton, All Rights Reserved.

Commercial Centres / Shopping Malls

Montedoro Freetime, Trieste Arkady Pankrac, Prague

Centro, Oberhausen Karstadt, Leipzig

Page 54: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

54 © 2015 Eaton, All Rights Reserved.

Commercial Centres / Shopping Malls

Dubai Mall, Dubai Deira City Centre, Dubai

Burjuman Expansion, Dubai Sahara Centre, Dubai

Page 55: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

55 © 2015 Eaton, All Rights Reserved.

Hotels

Emirates Palace, Abu Dhabi Atlantis, Dubai

Yas Marina, Abu Dhabi Madinat Jumeirah, Dubai

Page 56: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

56 © 2015 Eaton, All Rights Reserved.

Hotels

Jumeirah Beach Resort, Dubai Grand Hotel Portoroz, Slovenia

Kameha Grand, Bonn Marriott, Budapest

Page 57: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

57 © 2015 Eaton, All Rights Reserved.

Schools & Universities

Technical University Berlin Westfälische Wilhelms-University, Münster

University Dresden Ruhr University, Bochum

Page 58: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

58 © 2015 Eaton, All Rights Reserved.

Schools & Universities

University Groningen American University Sharjah

University Warwick, Coventry University Sote, Budapest

Page 59: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

59 © 2015 Eaton, All Rights Reserved.

Airports & Train Stations

Airport Frankfurt Airport Köln/Bonn

Airport Vienna Central Station Berlin

Page 60: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

60 © 2015 Eaton, All Rights Reserved.

Airports & Train Stations

Airport Dubai Airport Bangkok

Airport Athens Airport Copenhagen

Page 61: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

61 © 2015 Eaton, All Rights Reserved.

Industry

Ceska Rafinerska, Litvinov

Ruhr Oel GmbH, Site Scholven

Digital Park II, Bratislava Cinram, Alsdorf

Page 62: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

62 © 2015 Eaton, All Rights Reserved.

High-Rise Buildings

Burj Khalifa Bin Zayed,

Dubai

Capricorn Tower,

Dubai

Burj Al Arab,

Dubai

Page 63: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

63 © 2015 Eaton, All Rights Reserved.

High-Rise Buildings

Ritz-Carlton Doha, Qatar Tower 115, Bratislava

Capital Gate Tower, Abu Dhabi Fairmont Hotel, Dubai

Page 64: CEAG Emergency Lighting Solutions · CEAG Emergency Lighting Solutions ... When an emergency lighting system is put into operation, ... ZB-S substation US-S SOU1

64 © 2015 Eaton, All Rights Reserved.

CEAG Notlichtsysteme GmbH, Senator-Schwartz-Ring 26, D-59494 Soest

www.ceag.de