All information in this data sheet is accurate to the best of our knowledge at the time of printing. Please refer to www.lincolnelectric.eu for any udpated information. Fumes: Material Safety Data Sheets (MSDS) are available on our website.
Pipeliner® 8P+
Identification Imprint: 8010-P1 PIPELINER 8P+ Tip Color: none
GENERAL DESCRIPTION
Designed for vertical down welding of pipes up to and including X70Excellent resistance to porosity, X-ray quality weldsHigh stacking efficiency: fill joints in fewer passesExceptional mechanical propertiesRoot pass welding up to X80 grade pipe
Pipeliner®8P+: rev. C-EN22-01/02/16
CHEMICAL COMPOSITION (W%), TYPICAL, ALL WELD METAL
C Mn Si Ni Mo P S
0.17 0.7 0.25 0.8 0.2 0.01 0.01
PACKAGING AND AVAILABLE SIZES
Diameter (mm)Length (mm)
3.2 350
4.0 350
5.0 350
Metal can Net weight/unit (kg) 4.5 4.5 4.5
MECHANICAL PROPERTIES, TYPICAL, ALL WELD METAL
Condition
Yield strength(N/mm2)
Tensile strength(N/mm2)
Elongation(%)
Impact ISO-V(J)
-29°C -40°C -46°C
Required: AWS A5.5ISO 2560-A
Typical values
AW
min. 460min. 460
495
min. 550530-680
590
min. 19min. 20
24
min. 27
80
min. 47
60
50
WELDING POSITIONS (ISO/ASME) CURRENT TYPE
DC +
APPROVALS
ABS
+
CELLULOSIC ELECTRODE
PB/2FPA/1G PF/3GuPC/2G PE/4GPG/3Gd PJ/5GdPH/5Gu
CLASSIFICATIONAWS A5.5 E8010-P1 A-Nr 10ISO 2560-A E 46 4 1Ni C 2 5 F-Nr 3
9606 FM 1
www.lincolnelectric.eu
Pipeliner® 8P+
CALCULATION DATASizes
Diam. x length(mm)
Current range
(A)
Current type
3.2x3504.0x3505.0x350
65-120 100-165 130-210
DC+ DC+ DC+
*Stub end 35mm
REMARKS / APPLICATION ADVICE
Preheating pipe material L360 - L485 (X56 - X70) required (acc. EN 1011-2).Pipeclamps to be removed after finishing root pass, start welding hot pass (within 5 min) after root passUse electrodes directly from Metal cansUse PIPELINER 6P+ for lower hardness in the root pass when required
WELDING PARAMETERS, OPTIMUM FILL PASSES
Diameter (mm)
Welding positionsPH/5Gup PJ/5Gdown
3.2 4.0 5.0
90A 130A 150A
110A 150A 165A
EXAMPLES OF MATERIALS TO BE WELDED
Steel grades/Code TypePipe material
API 5LX X56, X60, X65, X70EN 10208-2 L360 up to L485
CELLULOSIC ELECTRODE