Identification Imprint: 8010-P1 PIPELINER 8P+ Tip Color: none

GENERAL DESCRIPTION

Designed for vertical down welding of pipes up to and including X70Excellent resistance to porosity, X-ray quality weldsHigh stacking efficiency: fill joints in fewer passesExceptional mechanical propertiesRoot pass welding up to X80 grade pipe

Pipeliner®8P+: rev. C-EN22-01/02/16

CHEMICAL COMPOSITION (W%), TYPICAL, ALL WELD METAL

C Mn Si Ni Mo P S

0.17 0.7 0.25 0.8 0.2 0.01 0.01

PACKAGING AND AVAILABLE SIZES

Diameter (mm)Length (mm)

3.2 350

4.0 350

5.0 350

Metal can Net weight/unit (kg) 4.5 4.5 4.5

MECHANICAL PROPERTIES, TYPICAL, ALL WELD METAL

Condition

Yield strength(N/mm2)

Tensile strength(N/mm2)

Elongation(%)

Impact ISO-V(J)

-29°C -40°C -46°C

Required: AWS A5.5ISO 2560-A

Typical values

AW

min. 460min. 460

495

min. 550530-680

590

min. 19min. 20

24

min. 27

80

min. 47

60

50

WELDING POSITIONS (ISO/ASME) CURRENT TYPE

DC +

APPROVALS

ABS

+

CELLULOSIC ELECTRODE

PB/2FPA/1G PF/3GuPC/2G PE/4GPG/3Gd PJ/5GdPH/5Gu

CLASSIFICATIONAWS A5.5 E8010-P1 A-Nr 10ISO 2560-A E 46 4 1Ni C 2 5 F-Nr 3

9606 FM 1

Page 2: CELLULOSIC ELECTRODE Pipeliner 8P+ - Lincoln … 5LX X56, X60, X65, X70 EN 10208-2 L360 up to L485 CELLULOSIC ELECTRODE Title Pipeliner 8P+ Author The Lincoln Electric Company Subject

www.lincolnelectric.eu

Pipeliner® 8P+

CALCULATION DATASizes

Diam. x length(mm)

Current range

(A)

Current type

3.2x3504.0x3505.0x350

65-120 100-165 130-210

DC+ DC+ DC+

*Stub end 35mm

REMARKS / APPLICATION ADVICE

Preheating pipe material L360 - L485 (X56 - X70) required (acc. EN 1011-2).Pipeclamps to be removed after finishing root pass, start welding hot pass (within 5 min) after root passUse electrodes directly from Metal cansUse PIPELINER 6P+ for lower hardness in the root pass when required

WELDING PARAMETERS, OPTIMUM FILL PASSES

Diameter (mm)

Welding positionsPH/5Gup PJ/5Gdown

3.2 4.0 5.0

90A 130A 150A

110A 150A 165A

EXAMPLES OF MATERIALS TO BE WELDED

Steel grades/Code TypePipe material

API 5LX X56, X60, X65, X70EN 10208-2 L360 up to L485

CELLULOSIC ELECTRODE