166
The chapter on success and failure (chapter 13) sub- stantiates the endodontic dogma of careful cavity preparation and canal obturation as the keystones to successful root canal therapy. Apical moisture-proof seal, the first essential for success, is not possible unless the space to be filled is carefully prepared and débrided to receive the restoration. As in restorative dentistry, the final restoration is rarely better than the initial cavity preparation. Endodontic cavity preparation begins the instant the involved tooth is approached with a cutting instru- ment, and the final obturation of the canal space will depend in great measure on the care and accuracy exer- cised in this initial preparation. DIVISIONS OF CAVITY PREPARATION For descriptive convenience, endodontic cavity prepa- ration may be separated into two anatomic divisions: (a) coronal preparation and (b) radicular preparation. Actually, coronal preparation is merely a means to an end, but to accurately prepare and properly fill the radicular pulp space, intracoronal preparation must be correct in size, shape, and inclination. If one thinks of an endodontic preparation as a con- tinuum from enamel surface to apex, Black’s principles of cavity preparation—Outline, Convenience, Retention, and Resistance Forms—may be applied (Figure 10-1). 1 The entire length of the preparation is the full outline form. In turn, this outline may have to be modified for the sake of convenience to accommo- date canal anatomy or curvature and/or instruments. In some techniques, the canal may be prepared for slight retention of a primary gutta-percha point. But most important, resistance must be developed at the apical terminus of the preparation, the so-called “apical stop,” the barrier against which virtually every canal filling must be compacted. CORONAL CAVITY PREPARATION Basic Coronal Instruments Preparations on and within the crown are completed with power-driven rotary instruments. For optimal operating efficiency, separate ranges of bur speed are needed. Although two handpieces are usually required, developments in electric handpiece engineering allow one motor to provide both low- and high-speed ranges of rpm. Handpieces are also being developed that auto- matically reverse on lockage of the file. 2 The correct burs are mounted by the dental assistant prior to their use. Rarely should a bur have to be placed or changed during the operation. For initial entrance through the enamel surface or through a restoration, the ideal cutting instrument is the round-end carbide fis- sure bur such as the Maillefer Transmetal bur or Endo Access diamond stone (Dentsply/Maillefer, Tulsa, Okla.), mounted in a contra-angle handpiece operating at accel- erated speed. With this instrument, enamel, resin, ceramic, or metal perforation is easily accomplished, and surface extensions may be rapidly completed. Porcelain-fused-to-metal restorations, however, are something else. Stokes and Tidmarsh have shown the effectiveness of various bur types in cutting through dif- ferent types of crowns 3 (Figure 10-2). Precious metal alloys are relatively easy to penetrate, whereas non- precious metals present considerable difficulty. Although nonprecious alloys can be cut with tungsten carbide burs, they “chatter” severely. This vibration results in patient discomfort and tends to loosen the crown from the luting cement. “The extra coarse, dome-ended cylinder…was the only bur type that cut smoothly and remained clini- cally effective during the cutting of five successive access cavities in the nonprecious metal” found frequently under metal-ceramic crowns. 3 Teplitsky and Sutherland also found diamond instrumentation perfect for access Chapter 10 ENDODONTIC CAVITY PREPARATION John I. Ingle, Van T. Himel, Carl E. Hawrish, Gerald N. Glickman, Thomas Serene, Paul A. Rosenberg, L. Stephen Buchanan, John D. West, Clifford J. Ruddle, Joe H. Camp, James B. Roane, and Silvia C. M. Cecchini

Ch10: ENDODONTIC CAVITY PREPARATION

  • Upload
    ledan

  • View
    310

  • Download
    10

Embed Size (px)

Citation preview

Page 1: Ch10: ENDODONTIC CAVITY PREPARATION

The chapter on success and failure (chapter 13) sub-stantiates the endodontic dogma of careful cavitypreparation and canal obturation as the keystones tosuccessful root canal therapy. Apical moisture-proofseal, the first essential for success, is not possible unlessthe space to be filled is carefully prepared and débridedto receive the restoration. As in restorative dentistry,the final restoration is rarely better than the initialcavity preparation.

Endodontic cavity preparation begins the instant theinvolved tooth is approached with a cutting instru-ment, and the final obturation of the canal space willdepend in great measure on the care and accuracy exer-cised in this initial preparation.

DIVISIONS OF CAVITY PREPARATION

For descriptive convenience, endodontic cavity prepa-ration may be separated into two anatomic divisions:(a) coronal preparation and (b) radicular preparation.Actually, coronal preparation is merely a means to anend, but to accurately prepare and properly fill theradicular pulp space, intracoronal preparation must becorrect in size, shape, and inclination.

If one thinks of an endodontic preparation as a con-tinuum from enamel surface to apex, Black’s principlesof cavity preparation—Outline, Convenience,Retention, and Resistance Forms—may be applied(Figure 10-1).1 The entire length of the preparation isthe full outline form. In turn, this outline may have tobe modified for the sake of convenience to accommo-date canal anatomy or curvature and/or instruments.In some techniques, the canal may be prepared forslight retention of a primary gutta-percha point. Butmost important, resistance must be developed at theapical terminus of the preparation, the so-called “apicalstop,” the barrier against which virtually every canalfilling must be compacted.

CORONAL CAVITY PREPARATION

Basic Coronal Instruments

Preparations on and within the crown are completedwith power-driven rotary instruments. For optimaloperating efficiency, separate ranges of bur speed areneeded. Although two handpieces are usually required,developments in electric handpiece engineering allowone motor to provide both low- and high-speed rangesof rpm. Handpieces are also being developed that auto-matically reverse on lockage of the file.2

The correct burs are mounted by the dental assistantprior to their use. Rarely should a bur have to be placedor changed during the operation. For initial entrancethrough the enamel surface or through a restoration, theideal cutting instrument is the round-end carbide fis-sure bur such as the Maillefer Transmetal bur or EndoAccess diamond stone (Dentsply/Maillefer, Tulsa, Okla.),mounted in a contra-angle handpiece operating at accel-erated speed. With this instrument, enamel, resin,ceramic, or metal perforation is easily accomplished, andsurface extensions may be rapidly completed.

Porcelain-fused-to-metal restorations, however, aresomething else. Stokes and Tidmarsh have shown theeffectiveness of various bur types in cutting through dif-ferent types of crowns3 (Figure 10-2). Precious metalalloys are relatively easy to penetrate, whereas non-precious metals present considerable difficulty. Althoughnonprecious alloys can be cut with tungsten carbide burs,they “chatter” severely. This vibration results in patientdiscomfort and tends to loosen the crown from the lutingcement. “The extra coarse, dome-ended cylinder…wasthe only bur type that cut smoothly and remained clini-cally effective during the cutting of five successive accesscavities in the nonprecious metal” found frequentlyunder metal-ceramic crowns.3 Teplitsky and Sutherlandalso found diamond instrumentation perfect for access

Chapter 10

ENDODONTIC CAVITY PREPARATIONJohn I. Ingle, Van T. Himel, Carl E. Hawrish, Gerald N. Glickman,

Thomas Serene, Paul A. Rosenberg, L. Stephen Buchanan, John D. West,

Clifford J. Ruddle, Joe H. Camp, James B. Roane, and Silvia C. M. Cecchini

Page 2: Ch10: ENDODONTIC CAVITY PREPARATION

openings in Cerestone (cast ceramic) crowns,4 as didCohen and Wallace with Dicor crowns.5 In Teplitsky andSutherland’s study, not a single crown fractured of 56prepared with diamonds. Carbide burs were ineffective.4

Tapered instruments should never be forced butshould be allowed to cut their own way with a lighttouch by the operator. If a tapered instrument is forced,it will act as a wedge. This causes the enamel to “check”or “craze” and will materially weaken the tooth (Figure10-3). If a porcelain jacket crown is to be entered, asmall diamond bur should be used. Again, care must beexercised not to split the jacket by forcing the action.

As soon as the enamel or restorative penetration andminor surface extensions are complete, the acceleratedhandpiece is put aside, and the slow-speed (3,000 to8,000 rpm) contra-angle handpiece is used, mountedwith a round bur. Three sizes of round burs, Nos. 2, 4,and 6, and two lengths, regular and surgical, are rou-tinely used. The regular-length round bur in a conven-tional latch-type contra-angle handpice will “reach” 9.0

406 Endodontics

mm from the nose of the contra-angle. Thesurgical-length bur will “reach” 14 or 15 mm and isnecessary in some deep preparations (Figure 10-4).

The round burs are for dentin removal in both ante-rior and posterior teeth. These burs are first used todrill through the dentin and “drop” into the pulpchamber. The same bur is then employed in theremoval of the roof of the pulp chamber. The choice ofthe size of the round bur is made by estimating thecanal width and chamber size and depth apparent inthe initial radiograph.

The No. 2 round bur is generally used in preparingmandibular anterior teeth and most maxillary premolarteeth with narrow chambers and canals. It is also occa-sionally used in the incisal pulp horn area of maxillaryanterior teeth. The No. 4 round bur is generally used inthe maxillary anterior teeth and the mandibular premo-lar teeth. It is also occasionally used in “young” maxil-lary premolars and “adult” molars in both arches, thatis, molars with extensive secondary dentin. The No. 6round bur is used only in molars with large pulp cham-bers. A No. 1 round bur is also occasionally used in thefloor of the pulp chamber to seek additional canal ori-fices. In addition, sonic and ultrasonic units, with spe-cially designed endodontic tips, allow clinicians to moreprecisely remove dentin and expose orifices. In con-junction with magnification (loupes, fiber-optic endo-scope, or microscope), the operator is better able tovisualize the pulp chamber floor.

As soon as the bulk of the overhanging dentin isremoved from the roof of the chamber, the sloweroperating round burs are put aside, and, once again, thehigh-speed fissure bur is used to finish and slope theside walls in the visible portions of the preparation.Again, the Maillefer Endo-Z carbide fissure bur(Dentsply/Maillefer, Tulsa, Okla.) is recommended. It issafe-ended and will not scar the pulpal floor. Moreover,it is longer bladed (9 mm) for sloping and funnelingthe access cavity.

Rotary cutting instruments, operating at greatlyaccelerated speeds, play a most important role inendodontic cavity preparation, especially for thepatient with discomfort. At the same time, a good dealof damage may be rendered with these instrumentsbecause of the loss of tactile sense in their use.High-speed burs should not be used to penetrate into,or initially enlarge, the pulp chamber unless the oper-ator is skilled in endodontic preparations. In this oper-ation, the clinician depends almost entirely on the“feel” of the bur deep inside the tooth, against the roofand walls of the pulp chamber, to judge the extensionsthat are necessary. High-speed equipment is operated

Figure 10-1 Concept of total endodontic cavity preparation,coronal and radicular as a continuum, based on Black’s principles.Beginning at apex: A, Radiographic apex. B, Resistance Form,development of the “apical stop” at the cementodentinal junctionagainst which filling is to be compacted and a stop to resist extru-sion of canal debris and filling material. C, Retention Form to retainprimary filling point. D, Convenience Form subject to revision asneeded to accommodate larger, less flexible instruments. Externalmodifications change the Outline Form. E, Outline Form, basicpreparation throughout its length dictated by canal anatomy.

Page 3: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 407

by sight alone and is not generally employed in a blindarea where reliance on tactile sensation is necessary.

Pulp Anatomy in Relation to Cavity Preparation

The alliance between endodontic cavity preparationand pulp anatomy is inflexible and inseparable. Tomaster the anatomic concept of cavity preparation, theoperator must develop a mental, three-dimensionalimage of the inside of the tooth, from pulp horn to api-cal foramen. Unfortunately, radiographs provide only a

two-dimensional “blueprint” of pulp anatomy. It is thethird dimension that the clinician must visualize, as asupplement to two-dimensional thinking, if one is toclean and shape accurately and fill the total pulp space(Plate 1, A).

Often the number or anatomy of the canals dictatesmodifications of the cavity preparation. If, for example,a fourth canal is found or suspected in a molar tooth,the preparation outline will have to be expanded toallow for easy, unrestrained access into the extra canal.

Figure 10-2 Comparison of round tungsten carbide burs versus extra-coarse dome-ended cylinder diamond burs used to cut nonpreciousalloys. A, Tungsten carbide round bur before use. B, Same bur after preparing five cavities. C, Extra-coarse diamond bur before use. D, Sameafter preparing two cavities. Loss of abrasive on dome end. Tungsten carbide burs always “chattered.” The coarse diamond bur was the onlyone “that cut smoothly and remained clinically effective” during five successive cavity preparations. Reproduced with permission from Stokes AN and Tidmarsh BG.3

Page 4: Ch10: ENDODONTIC CAVITY PREPARATION

On the other hand, it became quite fashionable togrossly expand cavity preparations to accommodatelarge instruments used in canal preparation or filling.This violates the basic tenets of endodontic cavitypreparation—gross modifications made for the sake ofthe clinician and the method rather than the moremodest convenience modifications that may be dictat-ed by the pulp anatomy itself.

PRINCIPLES OF ENDODONTIC CAVITY PREPARATION

Any discussion of cavity preparation must ultimatelyrevert to the basic Principles of Cavity Preparationestablished by G. V. Black.1 By slightly modifyingBlack’s principles, a list of principles of endodonticcavity preparation may be established. In laying downhis principles, Black dealt completely with cavitypreparations limited to the crowns of teeth; however,his principles can be applied to radicular preparationsas well. Endodontic preparations deal with both coro-nal and radicular cohorts—each prepared separatelybut ultimately flowing together into a single prepara-tion. For convenience of description, Black’s principlesare therefore divided into the following:

408 Endodontics

Endodontic Coronal Cavity PreparationI. Outline FormII. Convenience FormIII. Removal of the remaining carious dentin

(and defective restorations)IV. Toilet of the cavity

Endodontic Radicular Cavity PreparationI and II. Outline Form and Convenience Form (con-

tinued)IV. Toilet of the cavity (continued)V. Retention FormVI. Resistance Form

In the first half of this chapter, endodontic coronalcavity preparation will be discussed; the second halfwill be devoted to radicular preparation. A similarapproach to coronal preparation was suggested byPucci and Reig in 1944.6

Principle I: Outline Form

The outline form of the endodontic cavity must be cor-rectly shaped and positioned to establish completeaccess for instrumentation, from cavity margin to api-cal foramen. Moreover, external outline form evolvesfrom the internal anatomy of the tooth established bythe pulp. Because of this internal-external relationship,endodontic preparations must of necessity be done in areverse manner, from the inside of the tooth to the out-side. That is to say, external outline form is establishedby mechanically projecting the internal anatomy of thepulp onto the external surface. This may be accom-plished only by drilling into the open space of the pulpchamber and then working with the bur from theinside of the tooth to the outside, cutting away the

Figure 10-3 Forcing accelerated tapered bur or diamond severelycrazes lingual enamel. The instrument should be allowed to cut itsown way.

Figure 10-4 Two identical contra-angle handpieces holding No. 4round burs. The regular-length bur on the left will reach 9 mm. Thesurgical-length bur on the right will reach 14 mm.

Page 5: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 409

dentin of the pulpal roof and walls overhanging thefloor of the chamber (Plate 1, B).

This intracoronal preparation is contrasted to theextracoronal preparation of operative dentistry, inwhich outline form is always related to the externalanatomy of the tooth. The tendency to establishendodontic outline form in the conventional operativemanner and shape must be resisted (Plate 1, C).

To achieve optimal preparation, three factors ofinternal anatomy must be considered: (1) the size ofthe pulp chamber, (2) the shape of the pulp chamber,and (3) the number of individual root canals, their cur-vature, and their position.

Size of Pulp Chamber. The outline form ofendodontic access cavities is materially affected by thesize of the pulp chamber. In young patients, thesepreparations must be more extensive than in olderpatients, in whom the pulp has receded and the pulpchamber is smaller in all three dimensions (Plate 1, D).This becomes quite apparent in preparing the anteriorteeth of youngsters, whose larger root canals requirelarger instruments and filling materials—materialsthat, in turn, will not pass through a small orifice in thecrown (Plate 1, E).

Shape of Pulp Chamber. The finished outline formshould accurately reflect the shape of the pulp chamber.For example, the floor of the pulp chamber in a molartooth is usually triangular in shape, owing to the trian-gular position of the orifices of the canals. This triangu-lar shape is extended up the walls of the cavity and outonto the occlusal surface; hence, the final occlusal cavityoutline form is generally triangular (Plate 1, C). Asanother example, the coronal pulp of a maxillary pre-molar is flat mesiodistally but is elongated buccolingual-ly. The outline form is, therefore, an elongated oval thatextends buccolingually rather than mesiodistally, as doesBlack’s operative cavity preparation (Plate 1, F).

Number, Position, and Curvature of Root Canals.The third factor regulating outline form is the number,position, and curvature or direction of the root canals.To prepare each canal efficiently without interference,the cavity walls often have to be extended to allow anunstrained instrument approach to the apical foramen.When cavity walls are extended to improve instrumen-tation, the outline form is materially affected (Plate 1,G). This change is for convenience in preparation;hence, convenience form partly regulates the ultimateoutline form.

Principle II: Convenience Form

Convenience form was conceived by Black as a mod-ification of the cavity outline form to establish greater

convenience in the placement of intracoronal restora-tions. In endodontic therapy, however, convenienceform makes more convenient (and accurate) the prepa-ration and filling of the root canal. Four importantbenefits are gained through convenience form modifi-cations: (1) unobstructed access to the canal orifice, (2)direct access to the apical foramen, (3) cavity expansionto accommodate filling techniques, and (4) completeauthority over the enlarging instrument.

Unobstructed Access to the Canal Orifice. Inendodontic cavity preparations of all teeth, enoughtooth structure must be removed to allow instrumentsto be placed easily into the orifice of each canal withoutinterference from overhanging walls. The clinicianmust be able to see each orifice and easily reach it withthe instrument points. Failure to observe this principlenot only endangers the successful outcome of the casebut also adds materially to the duration of treatment(Plate 2, A to D).

In certain teeth, extra precautions must be taken tosearch for additional canals. The lower incisors are acase in point. Even more important is the high inci-dence of a second separate canal in the mesiobuccalroot of maxillary molars. A second canal often isfound in the distal root of mandibular molars as well.The premolars, both maxillary and mandibular, canalso be counted on to have extra canals. Duringpreparation, the operator, mindful of these variationsfrom the norm, searches conscientiously for addi-tional canals. In many cases, the outline form has tobe modified to facilitate this search and the ultimatecleaning, shaping, and filling of the extra canals(Figure 10-5).

Luebke has made the important point that an entirewall need not be extended in the event that instrumentimpingement occurs owing to a severely curved root oran extra canal (personal communication, April 1983)(Plate 1, G). In extending only that portion of the wallneeded to free the instrument, a cloverleaf appearancemay evolve as the outline form. Hence, Luebke hastermed this a “shamrock preparation” (Plate 1, H).

It is most important that as much crown structurebe maintained as possible. MOD cavity preparationsreduce tooth “stiffness” by more than 60%, and the“loss of marginal ridge integrity was the greatest con-tribution to loss of tooth strength.”7

Direct Access to the Apical Foramen. To providedirect access to the apical foramen, enough tooth struc-ture must be removed to allow the endodontic instru-ments freedom within the coronal cavity so they canextend down the canal in an unstrained position. Thisis especially true when the canal is severely curved or

Page 6: Ch10: ENDODONTIC CAVITY PREPARATION

A. A standard radiograph (left) in buccolingual pro-jection provides only a two-dimensional view ofwhat is actually a three-dimensional problem. If amesiodistal x-ray projection could be made(right), one would find the pulp of the maxillarysecond premolar to be flat tapering “ribbon” ratherthan round “thread” visualized on the initial radi-ograph. The final ovoid occlusal cavity preparation(F) will mirror the internal anatomy rather thanthe buccolingual x-ray image.

B. Coronal preparation of a maxillary first molarillustrating the major principle of endodontic cav-ity outline form: the internal anatomy of the tooth(pulp) dictates the external outline form. This isaccomplished by extending preparation frominside of the tooth to the outside surface, that is,working from inside to outside.

C. Endodontic cavity preparation, mandibular firstmolar, superimposed on inlay, restoring proxi-mal-occlusal surfaces. Black’s outline form ofinlay is related to the external anatomy and envi-ronment of the tooth, that is, the extent of cariouslesions, grooves, and fissures and the position ofthe approximating premolar. A triangular orrhomboidal outline form of endodontic prepara-tion, on the other hand, is related to the internalanatomy of the pulp. No relationship existsbetween the two outline forms.

D. Size and shape of endodontic coronal preparationsin mandibular incisors related to size and shape ofthe pulp and chamber. A contrast in outline formbetween a “young” incisor (left) with a large pulpand an adult incisor (right) is apparent. The large

triangular preparation in a youngster reflects pul-pal horn extension and size of the pulp chamber,whereas ovoid preparation in an adult relates to agrossly receded pulp. Extension toward the incisalallows central-axis access for instruments.

E. Large size and shape of coronal preparation in arecently calcified incisor relate to huge pulp hous-ing. To remove all pulp remnants and to accom-modate large endodontic instruments and fillingmaterials, coronal preparation must be an exten-sive, triangular, funnel-shaped opening. Actually,no more than the lingual wall of pulp chamber hasbeen removed. In lower incisors, the outline formmay well be extended into the incisal edge. Thispreparation allows absolutely direct access to apex.

F. The outline form of the endodontic coronal cavityin the maxillary first premolar is a narrow, elon-gated oval in buccolingual projection (bottom),which reflects the size and shape of a broad, flatpulp chamber of this particular tooth.

G. Buccal view of an inadequate coronal preparationin a maxillary molar with a defalcated mesiobuccalroot. There has been no compensation in cavitypreparation for severe curvature of the mesial canalor for the obtuse direction by which the canalleaves the chamber. The operator can no longermaintain control of the instrument, and a ledge hasbeen produced (arrow). Extension of the outlineform and internal preparation to the mesial (dot-ted line) would have obviated this failure.

H. “Shamrock preparation.” Modified outline form toaccommodate the instrument unrestrained in theseverely curved mesial canal seen in G.

PLATE 1

Outline Form

Page 7: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 1

Page 8: Ch10: ENDODONTIC CAVITY PREPARATION

leaves the chamber at an obtuse angle (Plate 2, E).Infrequently, total decuspation is necessary.

Extension to Accommodate Filling Techniques. Itis often necessary to expand the outline form to makecertain filling techniques more convenient or practical.If a softened gutta-percha technique is used for filling,wherein rather rigid pluggers are used in a verticalthrust, then the outline form may have to be widelyextended to accommodate these heavier instruments.

Complete Authority over the Enlarging Instrument.It is imperative that the clinician maintain completecontrol over the root canal instrument. If the instru-ment is impinged at the canal orifice by tooth structurethat should have been removed, the dentist will havelost control of the direction of the tip of the instru-ment, and the intervening tooth structure will dictatethe control of the instrument (Plate 2, G).

If, on the other hand, the tooth structure is removedaround the orifice so that the instrument stands free inthis area of the canal (Plate 2, H), the instrument willthen be controlled by only two factors: the clinician’sfingers on the handle of the instrument and the walls ofthe canal at the tip of the instrument. Nothing is tointervene between these two points (Plate 2, F).

412 Endodontics

Failure to properly modify the access cavity outlineby extending the convenience form will ultimately leadto failure by either root perforation, “ledge” or “shelf”formation within the canal, instrument breakage, orthe incorrect shape of the completed canal preparation,often termed “zipping” or apical transportation.

Principle III: Removal of the Remaining CariousDentin and Defective Restorations

Caries and defective restorations remaining in anendodontic cavity preparation must be removed for threereasons: (1) to eliminate mechanically as many bacteriaas possible from the interior of the tooth, (2) to eliminatethe discolored tooth structure, that may ultimately lead tostaining of the crown, and (3) to eliminate the possibilityof any bacteria-laden saliva leaking into the prepared cav-ity. The last point is especially true of proximal or buccalcaries that extend into the prepared cavity.

After the caries are removed, if a carious perforationof the wall is allowing salivary leakage, the area must berepaired with cement, preferably from inside the cavity.A small piece of premixed temporary cement, Cavit orCavit G (Premier Dental Products; Plymouth, Pa.), maybe forced through the perforation and applied to the

Figure 10-5 “Rogues’ Gallery” of aberrant canals, bifurcations, and foramina, all cleaned, shaped, and obturated successfully. (Courtesy ofDrs. L. Stephen Buchanan and Clifford J. Ruddle.)

Page 9: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 413

dry walls of the cavity, while care is taken to avoid forc-ing the cement into a canal orifice. A cotton pellet,moistened with any sterile aqueous solution such assaline or a local anesthetic, will cause the Cavit to set.Coronal perforations may also be repaired with adhe-sive composite resins placed by the acid-etch techniquein a perfectly dry milieu.

If the caries is so extensive that the lateral walls aredestroyed, or if a defective restoration is in place that isloose and leaking, then the entire wall or restorationshould be removed and later restored. It is importantthat restoration be postponed until the radicularpreparation has been completed. It is much easier tocomplete the radicular preparation through an opencavity than through a restored crown. As a matter offact, the more crown that is missing, the easier theradicular preparation becomes. The ultimate in ease ofoperation is the molar tooth broken off at the gingivallevel (Figure 10-6). As long as a rubber dam can beplaced on the tooth, it need not be built up with amal-gam, cement, or an orthodontic band; having to workthrough a hole only complicates the endodontic proce-dures. In addition, if the band comes off, the length oftooth measurements is invalidated and must bere-established. An adequate temporary filling canalways be placed in the remaining pulp chamber.

If enough tooth does not remain above the gingivato place a rubber dam clamp and seal against saliva, and

if it is imperative that the tooth be retained, a simplegingivoplasty will establish the required “crown”length. In any case, this procedure is usually necessarybefore the tooth can be restored. In this case, theocclusal cavity may be sealed and the incised gingivaprotected with the placement of a putty-like periodon-tal dressing over the entire stump and gingiva. Cotton,and then a thin layer of Cavit, should first cover thecanal orifices.

Principle IV: Toilet of the Cavity

All of the caries, debris, and necrotic material must beremoved from the chamber before the radicular prepa-ration is begun. If the calcified or metallic debris is leftin the chamber and carried into the canal, it may act asan obstruction during canal enlargement. Soft debriscarried from the chamber might increase the bacterialpopulation in the canal. Coronal debris may also stainthe crown, particularly in anterior teeth.

Round burs, of course, are most helpful in cavity toi-let. The long-blade, endodontic spoon excavator isideal for debris removal (Figure 10-7). Irrigation withsodium hypochlorite is also an excellent measure forcleansing the chamber and canals of persistent debris.

The chamber may finally be wiped out with cotton,and a careful flush of air will eliminate the remainingdebris. However, air must never be aimed down thecanals. Emphysema of the oral tissues has been pro-

Figure 10-6 Carious involvement of the maxillary molar hasdestroyed most of the crown. Enough tooth structure remains toadapt the rubber dam clamp. A wide-open cavity allows greater easeof operation. If the caries extends below the gingival level, gingivec-tomy will expose solid tooth structure.

Figure 10-7 Long-blade endodontic spoon excavator comparedwith standard Black’s spoon excavator. The long-blade instrument(left) is needed to reach the depths of molar preparations.

Page 10: Ch10: ENDODONTIC CAVITY PREPARATION

A. Obstructed access to mesial canals in a mandibularfirst molar. The overhanging roof of the pulp cham-ber misdirects the instrument mesially, with result-ing ledge formation in the canal. It is virtuallyimpossible to see and difficult to locate mesial canalorifices each time the instrument is introduced.

B. Internal cavity preparation. Removing the roofcompletely from the pulp chamber will bring canalorifices into view and allow immediate access toeach orifice. Using a round bur and working fromthe inside out will accomplish this end.

C. Final finish of the convenience form is completedwith a fissure bur, diamond point, or non–end-cut-ting batt bur. The entire cavity slopes toward themesial direction of approach, which greatly simpli-fies instrument placement.

D. Unobstructed access to canal orifices. The mesialwall has been sloped to mesial for the approach tothe mandibular molar is from the mesial. The tip ofthe instrument follows down the mesial wall ateach corner of the triangular preparation and liter-ally “falls” into orifices. After the position of eachorifice has been determined, the mouth mirrormay be laid aside.

The distal wall of preparation also slopes to themesial and is easily entered from the mesialapproach.

E. Direct access to apical foramen. Extensive removalof coronal tooth structure is necessary to allowcomplete freedom of endodontic instruments inthe coronal cavity and direct access to the apicalcanal. This is especially true when the root is severe-ly curved or leaves the chamber at an obtuse angle.

Walls are generally reduced with burs or long, thindiamond points (see B and C above) and withendodontic files, Gates-Glidden drills, or orificeopeners. Burs are rarely used in the floor or imme-diate orifice area. In the event that a second canal issuspected in the mesiobuccal root of the maxillarymolar, the cavity outline would be extended in bothof these directions to broaden the search.

Depending on the technique used to fill the canal,the outline form may also be expanded somewhatto accommodate pluggers used in obturation.

F. The complete authority of the enlarging instru-ment is maintained when all intervening toothstructure is removed and the instrument is con-trolled by the clinician’s fingers on the handle ofthe instrument and the tip of the instrument is freein the lumen of the canal.

G. Complete authority of enlarging instrument. Ifthe lateral wall of the cavity has not been suffi-ciently extended and the pulpal horn portion ofthe orifice still remains in the wall, the orifice willhave the appearance of a tiny “mouse hole.” Thislateral wall will then impinge on enlarging theinstrument and will dictate the direction of theinstrument tip. The operator will have lost controlof the instrument and the situation.

H. By extending the lateral wall of the cavity, thusremoving all intervening dentin from the orifice,the “mouse hole” in the wall will be eliminated andthe orifice will appear completely in the floor. Nowthe enlarging instrument will stand free of thewalls, and the operator will regain control of theinstrument (see F above).

PLATE 2

Convenience Form

Page 11: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 2

Page 12: Ch10: ENDODONTIC CAVITY PREPARATION

duced by a blast of air escaping out of the apex. In anin vitro study, Eleazer and Eleazer found a direct rela-tion between the size of the apical foramen and thelikelihood of expressing air into the periapical tissues.Addtional risks are incurred as air from these syringesis not sterile.8 Some dental schools do not allow the useof the three-way air/water syringe once access into thechamber has been achieved.

As previously stated, toilet of the cavity makes up asignificant portion of the radicular preparations.

DETAILED CORONAL CAVITY PREPARATION

Descriptions and Caveats

With the basic principles of endodontic cavity prepara-tion in mind, the student is urged to study the detailedplates that follow, each dealing with coronal prepara-tion. Again, keep in mind the importance of the intra-coronal preparation to the ultimate radicular prepara-tion and filling.

For each group of teeth—for example, maxillaryanterior teeth, mandibular premolar teeth—there is aplate showing in detail the suggested cavity preparationand operative technique applicable to that particulargroup of teeth. The technique plate is followed byplates of the individual teeth within the group. Fourseparate views of each tooth are presented: (1) thefacial-lingual view as seen in the radiograph; (2) themesiodistal view, impossible to obtain radiographicallybut necessary to the three-dimensional mental imageof the pulp anatomy; (3) a cross-sectional view at threelevels; and (4) a view of the occlusal or lingual surfacewith cavity outline form.

Detailed variations in preparation related to eachparticular tooth, as well as information about toothlength, root curvature, and canal anatomy variations,are presented. These plates are followed by a plate oferrors commonly committed in the preparation of thisgroup of teeth.

The mandibular incisors—centrals and laterals—are so anatomically similar that they are confined toone plate.

The reader is reminded that the preparations illus-trated here are minimal preparations, that the outlineform is a direct reflection of the pulp anatomy. If thepulp is expansive, the outline form will also be expan-sive. Furthermore, the outline form may have to begreatly enlarged to accept heavier instruments or rigidfilling materials.

Generally speaking, the length-of-tooth measure-ments are approximations. Nonetheless, they are help-ful and should alert the dentist to what to expect as“normal.” When there is a lack of agreement between

416 Endodontics

authors, we have chosen the larger figures, that is, thefigures furthest from normal.9–24 We have also adaptedliberally from the important work by Dempster et al.on the angulation of the teeth in the alveolar process.25

In addition, new information on multiple canals hasbeen brought to light.

Multiple and Extra Canals

Although it should come as no surprise, the high inci-dence of additional canals in molars, premolars, andmandibular incisors is significant. Hess, as early as1925, pointed out that 54% of his 513 maxillary molarspecimens had four canals.26 For years these facts weregenerally ignored.

At this juncture, however, one cannot help but bestruck by the magnitude of the numbers of additionalversus traditional canals. For example, maxillary molarsmay have four canals rather than three canals as muchas 95% of the time. Using a No. 1 round bur and/orultrasonic instruments to remove secondary dentinfrom the pulpal floor along the mesiobuccal-palatal legof the molar triangle will uncover an additional 31% ofthese orifices.27 An earlier study found these secondarycanals 69% of the time in vitro but only 31% in vivo.23

Another in vivo study found two canals in themesiobuccal roots of maxillary first molars 77% of thetime, and, of these, 62% had two apical foramina.28

Although a fourth root in maxillary molars is rare(0.4%),29,30 single-canal taurodontism (“bull-tooth”)was found in 11.3% of one patient cohort.31

The incidence of accessory canals in the furcation ofmaxillary molars, canals that extend all the way fromthe pulpal floor to the furcation area, is 48% in onestudy32 and 68% in another.33 These accessory canalsare only about twice the size of a dentinal tubule and soare rarely mistaken for a canal orifice even though theyare large enough to admit bacteria to the pulp from afurcal periodontal lesion. In mandibular molars,through-and-through furcal accessory canals are found56% of the time in one study32 and 48% in another.33

Mandibular molars also exhibit secondary rootcanals, over and above the traditional three. Althoughas many as five canals34 and as few as one and twocanals35,36 rarely occur in mandibular molars, fourcanals are not unusual. Bjorndal and Skidmore report-ed this occurrence 29% of the time in a US cohort, asecond distal canal being the usual anomaly.23 TheChinese found four canals in 31.5% of their cases.37

Weine et al. however, reported that only 12.5% of theirsecond molar specimens had a second distal canal andthat only one had two separate apical foramina.35

Anomalies also occur in the mesial root.38

Page 13: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 417

Premolar teeth are also prone to secondary canals.Maxillary first premolars, which generally have twocanals, have three canals 5 to 6% of the time.14,39

Twenty-four percent of maxillary second premolarshave second root canals and occasionally three canals.15

In Brazil, two canals were found 32.4% of the time andthree canals in 0.3% of the cases.40

Mandibular premolars are notorious for havingextra canals—26.5% in first premolars and 13.5% insecond premolars.21 A US Army group reported canalbifurcations as deep as 6 to 9 mm from the coronal ori-fice 74% of the time in mandibular first premolars.22

Almost one-third of all mandibular lateral incisorshave two canals with two foramina.11 A Turkish reportlists two newly defined canal configurations, one thatends in three separate foramina.12

Every dentist who has done considerable root canaltherapy must ask, “How many of these extra canalshave I failed to find in the past?” Also, there appears tobe a wide discrepancy between the figures quotedabove, which are based on laboratory studies, and thosefound under clinical conditions. Hartwell and Bellizifound four canals in maxillary first molars only 18% ofthe time in vivo (in comparison to the figure of 85%found in vitro, cited above).41 In mandibular firstmolars, the reverse was true: they actually filled afourth canal 35% of the time, whereas 29% of extract-ed teeth had a fourth canal.41

How may one account for the wide discrepancybetween these figures of incidence of additional canals?

Ethnic variance may be one part of the equation.African Americans have more than twice as manytwo-canal mandibular premolars (32.8% versus13.7%) than do Caucasian patients: “Four out of tenblack patients had at least one lower premolar with twoor more canals.”42 In a southern Chinese population,however, the roots of mandibular second molars arefused 52% of the time and only have two canals, ratherthan three, 55% of the time.36 The Chinese also havetwo canal lower incisors 27% of the time, but only 1%terminate in two foramina,43 compared to two forami-na terminations 30% of the time in a US study.11 ABrazilian study reports two canals with two foramina in1.2% of mandibular canines.44

The incidence of taurodontism varies all over theworld. In Saudi Arabia, 43.2% of adult molars studiedwere taurodonts in 11.3% of the patient cohort.31 InBrazil, 11 cases of taurodontism in mandibular pre-molars, a very rare occurrence, were described.45 Theseminal studies of Pineda and Kuttler were done inMexico on extracted teeth, many presumably from anative cohort.14,18

In any event, anomalous and multiple canals are aworldwide problem, a fact that makes imperative acareful search in every tooth for additional canals. Justas important, the facts emphasize the necessity ofchoosing a method of preparation and filling that willensure the obturations of these additional canals (seeFigure 10-5).

Page 14: Ch10: ENDODONTIC CAVITY PREPARATION
Page 15: Ch10: ENDODONTIC CAVITY PREPARATION

Plates 3 to 27

Folio ofCORONAL ENDODONTICCAVITY PREPARATIONS

Originally Illustrated by

VIRGINIA E. BROOKS

Modified by

PHYLLIS WOOD

Page 16: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the lingual sur-face of all anterior teeth. Initial penetration ismade in the exact center of the lingual surface atthe position marked “X.” A common error is tobegin the cavity too far gingivally.

B. Initial entrance is prepared with a round-pointtapering fissure bur in an accelerated-speed con-tra-angle handpiece with air coolant, operated at aright angle to the long axis of the tooth. Onlyenamel is penetrated at this time. Do not force thebur; allow it to cut its own way.

C. Convenience extension toward the incisal contin-ues the initial penetrating cavity preparation.Maintain the point of the bur in the central cavityand rotate the handpiece toward the incisal so thatthe bur parallels the long axis of the tooth. Enameland dentin are beveled toward the incisal.Entrance into the pulp chamber should not bemade with an accelerated-speed instrument. Lackof tactile sensation with these instruments pre-cludes their use inside the tooth.

D. The preliminary cavity outline is funneled andfanned incisally with a fissure bur. Enamel has ashort bevel toward the incisal, and a “nest” is pre-pared in the dentin to receive the round bur to beused for penetration.

E. A surgical-length No. 2 or 4 round bur in aslow-speed contra-angle handpiece is used to pen-etrate the pulp chamber. If the pulp has greatlyreceded, a No. 2 round bur is used for initial pene-tration. Take advantage of convenience extensiontoward the incisal to allow for the shaft of the pen-etrating bur, operated nearly parallel to the longaxis of the tooth.

F. Working from inside the chamber to outside, around bur is used to remove the lingual and labialwalls of the pulp chamber. The resulting cavity issmooth, continuous, and flowing from cavity mar-gin to canal orifice.

G. After the outline form is completed, the surgical-length bur is carefully passed into the canal.Working from inside to outside, the lingual “shoul-der” is removed to give continuous, smooth-flowingpreparation. Often a long, tapering diamond pointwill better remove the lingual “shoulder.”

H. Occasionally, a No. 1 or 2 round bur must be usedlaterally and incisally to eliminate pulpal horndebris and bacteria. This also prevents future dis-coloration.

I. Final preparation relates to the internal anatomyof the chamber and canal. In a “young” tooth witha large pulp, the outline form reflects a large trian-gular internal anatomy—an extensive cavity thatallows thorough cleansing of the chamber as wellas passage of large instruments and filling materi-als needed to prepare and fill a large canal. Cavityextension toward the incisal allows greater access tothe midline of the canal.

J. Cavity preparations in “adult” teeth, with thechamber obturated with secondary dentin, areovoid in shape. Preparation funnels down to theorifice of the canal. The further the pulp has reced-ed, the more difficult it is to reach to this depthwith a round bur. Therefore, when the radiographreveals advanced pulpal recession, convenienceextension must be advanced further incisally toallow the bur shaft and instruments to operate inthe central axis.

K. Final preparation with the reamer in place. Theinstrument shaft clears the incisal cavity marginand reduced lingual “shoulder,” allowing an unre-strained approach to the apical third of the canal.The instrument remains under the complete con-trol of the clinician. An optimal, round, taperedcavity may be prepared in the apical third, tailoredto the requirements of round, tapered filling mate-rials to follow. The remaining ovoid part of thecanal is cleaned and shaped by circumferential fil-ing or Gates-Glidden drills.

PLATE 3

Endodontic Preparation of Maxillary Anterior Teeth

Page 17: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 3

Page 18: Ch10: ENDODONTIC CAVITY PREPARATION

A. Lingual view of a recently calcified incisor with alarge pulp. A radiograph will reveal1. extent of the pulp horns2. mesiodistal width of the pulp3. apical-distal curvature (8% of the time)4. 2-degree mesial-axial inclination of the toothThese factors seen in the radiograph are borne inmind when preparation is begun.

B. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. presence of a lingual “shoulder” at the point

where the chamber and canal join2. broad labiolingual extent of the pulp3. 29-degree lingual-axial angulation of the tooth

The operator must recognize thata. the lingual “shoulder” must be removed with a

tapered diamond point to allow better accessto the canal.

b. these “unseen” factors affect the size, shape,and inclination of final preparation.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, wider in the mesiodistal dimension.Débridement in this area is accomplished byextensive perimeter filing.

2. Midroot level: the canal continues ovoid andrequires perimeter filing and multiple pointfilling.

3. Apical third level: the canal, generally round inshape, is enlarged by reshaping the cavity intoa round tapered preparation. Preparation ter-minates at the cementodentinal junction, 0.5to 1.0 mm from the radiographic apex. Anunusually large apical third canal is more ovoidin shape, must be prepared with perimeter fil-ing rather than reaming, and must be obturat-ed with multiple points or warm gutta-percha.

D. Large, triangular, funnel-shaped coronal prepara-tion is necessary to adequately débride the cham-ber of all pulp remnants. (The pulp is “ghosted” inthe background.) Note the beveled extensiontoward the incisal that will carry the preparation

labially and thus nearer the central axis. Incisalextension allows better access for large instrumentsand filling materials used in the apical third canal.

E. Lingual view of an adult incisor with extensive sec-ondary dentin formation.A radiograph will reveal1. full pulpal recession2. apparently straight canal3. 2-degree mesial-axial inclination of the tooth

F. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. narrow labiolingual width of pulp2. reduced size of the lingual shoulder3. apical-labial curvature (9% of the time)4. 29-degree lingual-axial angulation of the tooth

The operator must recognize thata. a small canal orifice is difficult to find.b. apical-labial curvature, not usually seen radi-

ographically, can be determined by explo-ration with a fine curved file and mesially ori-ented radiographs.

c. axial inclination of the root calls for carefulorientation and alignment of the bur to pre-vent “gouging.”

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the canal, only slightly ovoid,

becomes progressively more round.2. Midroot level: the canal varies from slightly

ovoid to round.3. Apical third level: the canal is generally round

in the older patient.

H. Ovoid, funnel-shaped coronal preparation pro-vides adequate access to the root canal. The pulpchamber, obturated by secondary dentin, need notbe extended for coronal débridement. “Adult” cav-ity preparation is narrow in the mesiodistal widthbut is almost as extensive in the incisogingivaldirection as preparation in a young tooth. Thisbeveled incisal extension carries preparation near-er the central axis, allowing better access to thecurved apical third.

PLATE 4

Maxillary Central Incisor

Pulp Anatomy and Coronal Preparation

Page 19: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 4

Maxillary Central Incisors

Length of tooth Canal Lateral canals Apical ramifications Root curvature

Average Length 23.3 mm One canal 23% 13% Straight 75%Maximum Length 25.6 mm 100% Distal Curve 8%Minimum Length 21.0 mm Mesial Curve 4%Range 4.6 mm *Labial Curve 9%

*Lingual Curve 4%*Not apparent in radiograph

Page 20: Ch10: ENDODONTIC CAVITY PREPARATION

A. Lingual view of a recently calcified incisor with alarge pulp. A radiograph will reveal1. extent of the pulp horns2. mesiodistal width of the pulp3. apical-distal curvature (53% of the time)4. 16-degree mesial-axial inclination of the toothFactors seen in the radiograph are borne in mindwhen preparation is begun.

B. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. presence of a lingual “shoulder” at the point

where the chamber and canal join2. broad labiolingual extent of the pulp3. 29-degree lingual-axial angulation of tooth

The operator must recognize thata. the lingual “shoulder” must be removed with a

tapered diamond point to allow better accessto the canal.

b. these “unseen” factors will affect the size,shape, and inclination of final preparation.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is large in a young

tooth and wider in the labiolingual dimension.Débridement in this area is accomplished byextensive perimeter filing.

2. Midroot level: the canal continues ovoid andrequires additional filing to straighten the grad-ual curve. Multiple point filling is necessary.

3. Apical third level: the canal, generally roundand gradually curved, is enlarged by filing to astraightened trajectory. Preparation is com-pleted by shaping the cavity into a round,tapered preparation. Preparation terminates atthe cementodentinal junction, 0.5 to 1.0 mmfrom the radiographic apex.

D. Large, triangular, funnel-shaped coronal prepara-tion is necessary to adequately débride the chamberof all pulpal remnants. (The pulp is “ghosted” in thebackground.) Note the beveled extension toward theincisal, which will carry the preparation labially andthus nearer the central axis. Incisal extension allowsbetter access to the apical third of the canal.

E. Lingual view of an adult incisor with extensive sec-ondary dentin formation.A radiograph will reveal1. full pulp recession2. severe apical curve to the distal3. 16-degree mesial-axial inclination of the tooth

F. Distal view of the same tooth demonstratingdetails not apparent in the radiograph1. narrow labiolingual width of the pulp2. reduced size of the lingual shoulder3. apical-lingual curvature (4% of the time)4. 29-degree lingual-axial angulation of the tooth

The operator must recognize thata. a small canal orifice is difficult to find.b. apical-lingual curvature, not usually seen radi-

ographically, can be determined by explo-ration with a fine curved file and mesially ori-ented radiographs.

c. axial inclination of the root calls for carefulorientation and alignment of the bur to pre-vent labial “gouging.” A “corkscrew” curve, tothe distal and lingual, complicates preparationof the apical third of the canal.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the canal is only slightly ovoid

and becomes progressively rounder.2. Midroot level: the canal varies from slightly

ovoid to round.3. Apical third level: the canal is generally round

in the older patient.A curved canal is enlarged by alternate reamingand filing. Ovoid preparation will require multiplepoint filling.

H. Ovoid, funnel-shaped coronal preparation shouldbe only slightly skewed toward the mesial to pres-ent better access to the apical-distal. It is not neces-sary to extend preparation for coronal débride-ment, but an extensive bevel is necessary towardthe incisal to carry preparation nearer the centralaxis, allowing better access to the apical third.

PLATE 5

Maxillary Lateral Incisor

Pulp Anatomy and Coronal Preparation

Page 21: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 5

Maxillary Lateral Incisors

Length of tooth Canal Lateral canals Apical ramifications Root curvature

Average Length 22.8 mm One canal 10% 12% Straight 30%Maximum Length 25.1 mm 99.9% Distal Curve 53%Minimum Length 20.5 mm Mesial Curve 3%Range 4.6 mm *Labial Curve 4%

*Bayonet and 6%Gradual Curve

*Not apparent in radiograph

Page 22: Ch10: ENDODONTIC CAVITY PREPARATION

A. Lingual view of a recently calcified canine with alarge pulp. A radiograph will reveal1. coronal extent of the pulp2. narrow mesiodistal width of the pulp3. apical-distal curvature (32% of the time)4. 6-degree distal-axial inclination of the toothThese factors, seen in the radiograph, are borne inmind when preparation is begun, particularly thesevere apical curve.

B. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. huge ovoid pulp, larger labiolingually than the

radiograph would indicate2. presence of a labial “shoulder” just below the

cervical3. narrow canal in the apical third of the root4. 21-degree lingual-axial angulation of the toothThese “unseen” factors will affect the size, shape,and inclination of the final preparation.

C. Cross-section is at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, much wider in the labiolingual direc-tion. Débridement in this area is accomplishedwith a long, tapered diamond point and exten-sive perimeter filing.

2. Midroot level: the canal continues ovoid inshape and requires perimeter filing and multi-ple point filling.

3. Apical third level: the straight canal (39% oftime), generally round in shape, is prepared byshaping the cavity into round tapered prepara-tion. Preparation should terminate at the cemen-todentinal junction, 0.5 to 1.0 mm from theradiographic apex. If unusually large or curved,the apical canal requires perimeter filing andmultiple point or warm gutta-percha filling.

D. Extensive, ovoid, funnel-shaped coronal prepara-tion is necessary to adequately débride the cham-ber of all pulpal remnants. (The pulp is “ghosted”

in the background.) Note the long, beveled exten-sion toward the incisal, which will carry the prepa-ration labially and thus nearer the central axis.Incisal extension allows better access for largeinstruments and filling materials used in the apicalthird of the canal.

E. Lingual view of an adult canine with extensive sec-ondary dentin formation. A radiograph will reveal1. full pulp recession2. straight canal (39% of the time)3. 6-degree distal-axial inclination of tooth

F. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. narrow labiolingual width of the pulp2. apical labial curvature (13% of the time)3. 21-degree lingual-axial angulation of the tooth

The operator should recognize thata. a small canal orifice is difficult to find.b. apical labial curvature, not seen radiographi-

cally, can be determined only by explorationwith a fine curved file and mesially orientedradiographs.

c. distal-lingual axial inclination of the root callsfor careful orientation and alignment of thebur to prevent “gouging.”

d. apical foramen toward the labial is a problem.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the canal is slightly ovoid.2. Midroot level: the canal is smaller but remains

ovoid.3. Apical third level: the canal becomes progres-

sively rounder.

H. Extensive, ovoid, funnel-shaped preparation mustbe nearly as large as for a young tooth. A beveledincisal extension carries preparation nearer thecentral axis, allowing better access to the curvedapical third. Discovery by exploration of an apical-labial curve calls for even greater incisal extension.

PLATE 6

Maxillary Canine

Pulp Anatomy and Coronal Preparation

Page 23: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 6

Maxillary Canines

Length of tooth Canal Lateral canals Apical ramifications Root curvature

Average Length 26.0 mm One canal 24% 8% Straight 39%Maximum Length 28.9 mm 100% Distal Curve 32%Minimum Length 23.1 mm Mesial Curve 0%Range 5.8 mm *Labial Curve 13%

*Lingual Curve 7%Bayonet and 7%

Gradual Curve*Not apparent in radiograph

Page 24: Ch10: ENDODONTIC CAVITY PREPARATION

A. PERFORATION at the labiocervical caused by fail-ure to complete convenience extension toward theincisal, prior to the entrance of the shaft of the bur.

B. GOUGING of the labial wall caused by failure torecognize the 29-degree lingual-axial angulation ofthe tooth.

C. GOUGING of the distal wall caused by failure torecognize the 16-degree mesial-axial inclination ofthe tooth.

D. PEAR-SHAPED PREPARATION of the apical canalcaused by failure to complete convenience exten-sions. The shaft of the instrument rides on the cav-ity margin and lingual “shoulder.” Inadequatedébridement and obturation ensure failure.

E. DISCOLORATION of the crown caused by failureto remove pulp debris. The access cavity is too farto the gingival with no incisal extension.

F. LEDGE formation at the apical-distal curve causedby using an uncurved instrument too large for thecanal. The cavity is adequate.

G. PERFORATION at the apical-distal curve causedby using too large an instrument through an inad-equate preparation placed too far gingivally.

H. LEDGE formation at the apical-labial curve causedby failure to complete the convenience extension.The shaft of the instrument rides on the cavitymargin and “shoulder.”

PLATE 7

Maxillary Anterior Teeth

ERRORS in Cavity Preparation

Page 25: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 7

Page 26: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the lingual sur-face of all anterior teeth. Initial penetration is madein the exact center of the lingual surface at the posi-tion marked “X.” A common error is to begin toofar gingivally.

B. The initial entrance cavity is prepared with a 701 Utapering fissure bur in an accelerated-speed con-tra-angle handpiece with air coolant, operated at aright angle to the long axis of the tooth. Onlyenamel is penetrated at this time. Do not force thebur; allow it to cut its own way.

C. Convenience extension toward the incisal continuesinitial penetrating cavity. Maintain the point of thebur in the central cavity and rotate the handpiecetoward the incisal so that the bur parallels the longaxis of the tooth. Enamel and dentin are beveledtoward the incisal. Entrance into the pulp chambershould not be made with an accelerated-speedinstrument. Lack of tactile sensation with theseinstruments precludes their use inside the tooth.

D. The preliminary cavity outline is funneled andfanned incisally with a fissure bur. The enamel hasa short bevel toward the incisal, and a “nest” is pre-pared in the dentin to receive the round bur to beused for penetration.

E. A surgical-length No. 2 round bur in a slow-speedcontra-angle handpiece is used to penetrate into thepulp chamber. If the pulp has greatly receded, theNo. 2 round bur is used for initial penetration. Takeadvantage of convenience extension toward theincisal to allow for the shaft of the penetrating bur,operated nearly parallel to the long axis of the tooth.

F. Working from inside the chamber to the outside, around bur is used to remove the lingual and labialwalls of the pulp chamber. The resulting cavity issmooth, continuous, and flowing from cavity mar-gin to canal orifice.

G. After the outline form is completed, a surgical-lengthbur is carefully passed down into the canal. Working

from inside to outside, the lingual “shoulder” isremoved with a long, fine, tapered diamond point togive a continuous, smooth-flowing preparation.

H. Occasionally, a No. 1 round bur must be used lat-erally and incisally in the cavity to eliminate pulpalhorn debris and bacteria. This also prevents futurediscoloration.

I. Final preparation related to the internal anatomyof the chamber and canal. In a “young” tooth witha large pulp, the outline form reflects triangularinternal anatomy—an extensive cavity that allowsthorough cleansing of the chamber as well as pas-sage of large instruments and filling materialsneeded to prepare and fill the large canal. Noteextension toward the incisal to allow better accessto the central axis.

J. Cavity preparations in an “adult” tooth with thechamber obliterated with secondary dentin areovoid. Preparation funnels down to the orifice ofthe canal. The further the pulp has receded, themore difficult it is to reach to this depth with around bur. Therefore, when a radiograph revealsadvanced pulpal recession, convenience exten-sion must be advanced further incisally to allowthe bur shaft to operate in the central axis. Theincisal edge may even be invaded and laterrestored by composites.

K. Final preparation showing the reamer in place.The instrument shaft clears the incisal cavitymargin and reduced lingual shoulder, allowing anunrestrained approach to the apical third of thecanal. The instruments remain under the com-plete control of the clinician. Great care must betaken to explore for additional canals, particular-ly to the lingual of the pulp chamber. An optimalround, tapered cavity may be prepared in the api-cal third, tailored to requirements of round,tapered filling materials to follow. The remainingovoid part of the canal is cleaned and shaped byextensive filing.

PLATE 8

Endodontic Preparation of Mandibular Anterior Teeth

Page 27: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 8

Page 28: Ch10: ENDODONTIC CAVITY PREPARATION

A. Lingual view of a recently calcified incisor with alarge pulp. A radiograph will reveal1. extent of the pulp horns2. mesiodistal width of the pulp3. slight apical-distal curvature of the canal (23%

of the time)4. mesial-axial inclination of the tooth (central

incisor 2 degrees, lateral incisor 17 degrees).These factors, seen in the radiograph, are borne inmind when preparation is begun.

B. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. presence of a lingual “shoulder” at the point

where the chamber and canal join2. broad labiolingual extent of the pulp3. 20-degree lingual-axial angulation of the tooth

The operator must recognize thata. the lingual “shoulder” must be removed with a

fine, tapered diamond point to allow betteraccess to the canal.

b. these “unseen” factors affect the size, shape,and inclination of the final preparation.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, wider in the labiolingual dimension.Débridement in this area is accomplished byextensive perimeter filing.

2. Midroot level: the canal continues ovoid andrequires perimeter filing and multiple pointfilling.

3. Apical third level: the canal, generally round inshape, is enlarged by shaping the cavity into around, tapered preparation. Preparation ter-minates at the cementodentinal junction, 0.5to 1.0 mm from the radiographic apex.

D. Large, triangular, funnel-shaped coronal prepara-tion is necessary to adequately débride the chamberof all pulp remnants. (The pulp is “ghosted” in thebackground.) Note the beveled extension toward theincisal, which will carry the preparation labially andthus nearer the central axis. Incisal extension allowsbetter access for instruments and filling materialsused in the apical third of the canal.

E. Lingual view of an adult incisor with extensive sec-ondary dentin formation.A radiograph will reveal:1. full pulp recession2. an apparently straight canal3. mesial-axial inclination of the tooth (central

incisor 2 degrees, lateral incisor 17 degrees).

F. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. labiolingual width of the pulp2. reduced size of the lingual shoulder3. unsuspected presence of bifurcation of pulp

into the labial and lingual canals nearly 30%of the time

4. 20-degree lingual-axial angulation of the tooth

The operator must recognize thata. smaller canal orifices are more difficult to find.b. labial and lingual canals are discovered by

exploration with a fine curved file to both labi-al and lingual.

c. axial inclination of the root calls for carefulorientation and alignment of the bur to pre-vent “gouging.”

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the canal is only slightly ovoid.2. Midroot level: the two canals are essentially

round.3. Apical third level: the canals are round and

curve toward the labial.It is important that all mandibular anterior teethbe explored to both labial and lingual for the pos-sibility of two canals.

H. Ovoid, funnel-shaped coronal preparation providesadequate access to the root canal. An “adult” cavity isnarrow in the mesiodistal width but is as extensive inthe incisogingival direction as preparation in ayoung tooth. This beveled incisal extension carriespreparation nearer to the central axis. The incisaledge may even be invaded. This will allow betteraccess to both canals and the curved apical third.Ideal lingual extension and better access will oftenlead to discovery of the second canal.

PLATE 9

Mandibular Central and Lateral Incisors

Pulp Anatomy and Coronal Preparation

Page 29: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 9

Mandibular Central and Lateral Incisors

Central Lateral Central Lateral

Length of tooth Incisors Incisors Canals Incisors Incisors Root curvature

Average Length 21.5 mm 22.4 mm One canal 70.1% 56.9% Straight 60%One foramen

Maximum Length 23.4 mm 24.6 mm Two canals 23.4% 14.7% Distal Curve 23%One foramen

Minimum Length 19.6 mm 20.2 mm Two canals 6.5% 29.4% Mesial Curve 0%Two foramens

Range 3.8 mm 4.4 mm Lateral canals 5.2% 13.9% *Labial Curve 13%*Lingual Curve 0%*Not apparent in radiograph

Page 30: Ch10: ENDODONTIC CAVITY PREPARATION

A. Lingual view of a recently calcified canine with alarge pulp. A radiograph will reveal1. coronal extent of the pulp2. narrow mesiodistal width of the pulp3. apical-distal curvature (20% of the time)4. 13-degree mesial-axial inclination of toothThese factors, seen in the radiograph, are borne inmind when preparation is begun.

B. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. broad labiolingual extent of the pulp2. narrow canal in the apical third of the root3. apical-labial curvature (7% of time)4. 15-degree lingual-axial angulation of the toothThese “unseen factors” affect the size, shape, andinclination of the final preparation.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, wider in the labiolingual direction.Débridement in this area is accomplished withextensive perimeter filing.

2. Midroot level: the canal continues ovoid andrequires perimeter filing and multiplegutta-percha point filling.

3. Apical third level: the canal, generally round, isenlarged by filing to reduce the curve to a rela-tively straight canal. This canal is then complet-ed by shaping action into round, tapered prepa-ration. Preparation terminates at the cemento-dentinal junction, 0.5 to 1.0 mm from the radi-ograph apex. If unusually large or ovoid, theapical canal requires perimeter filing.

D. Extensive ovoid, funnel-shaped coronal prepara-tion is necessary to adequately débride the cham-ber of all pulp remnants. (The pulp is “ghosted” in

the background.) Note the beveled extensiontoward the incisal, which will carry the preparationlabially and thus nearer the central axis. Incisalextension allows better access for large instrumentsand filling materials used in the apical third canal.

E. Lingual view of an adult canine with extensive sec-ondary dentin formation. A radiograph will reveal1. full pulp recession2. slight distal curve of the canal (20% of the

time)3. 13-degree mesial-axial inclination of the tooth

F. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. labiolingual width of the pulp2. 15-degree lingual-axial angulation of the toothThe operator must recognize thata. a small canal orifice, positioned well to the

labial, is difficult to find.b. lingual-axial angulation calls for careful orien-

tation of the bur to prevent “gouging.”c. apical-labial curvature (7% of the time).

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the canal is slightly ovoid.2. Mid-root level: the canal is smaller but remains

ovoid.3. Apical third level: the canal becomes progres-

sively rounder.The canal is enlarged by filing and is filled.

H. Extensive ovoid, funnel-shaped preparations mustbe as large as preparation for a young tooth. Thecavity should be extended incisogingivally forroom to find the orifice and enlarge the apical thirdwithout interference. An apical-labial curve wouldcall for increased extension incisally.

PLATE 10

Mandibular Canine

Pulp Anatomy and Coronal Preparation

Page 31: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 10

Mandibular Canines

Length of tooth Canals Lateral canals Root curvature

Average Length 25.2 mm One canal 94% 9.5% Straight 68%Maximum Length 27.5 mm Two canals Distal Curve 20%Minimum Length 22.9 mm Two foramina 6% Mesial Curve 1%Range 4.6 mm *Labial Curve 7%

*Lingual Curve 0%Bayonet Curve 2%*Not apparent in radiograph

Page 32: Ch10: ENDODONTIC CAVITY PREPARATION

A. GOUGING at the labiocervical caused by failure tocomplete convenience extension toward the incisalprior to entrance of the shaft of the bur.

B. GOUGING of the labial wall caused by failure torecognize the 20-degree lingual-axial angulation ofthe tooth.

C. GOUGING of the distal wall caused by failure torecognize the 17-degree mesial-axial angulation ofthe tooth.

D. FAILURE to explore, débride, or fill the secondcanal caused by inadequate incisogingival exten-sion of the access cavity.

E. DISCOLORATION of the crown caused by failureto remove pulp debris. The access cavity is too farto the gingival with no incisal extension.

F. LEDGE formation caused by complete loss of con-trol of the instrument passing through the accesscavity prepared in proximal restoration.

PLATE 11

Mandibular Anterior Teeth

ERRORS in Cavity Preparation

Page 33: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 11

Page 34: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the occlusal sur-face of all posterior teeth. Initial penetration ismade parallel to the long axis of the tooth in theexact center of the central groove of the maxillarypremolars. The 701 U tapering fissure bur in anaccelerated-speed contra-angle handpiece is idealfor penetrating gold casting or virgin enamel sur-face to the depth of the dentin. Amalgam fillingsare opened with a No. 4 round bur in a slow-speedcontra-angle handpiece.

B. A regular-length No. 2 or 4 round bur is used toopen into the pulp chamber. The bur will be felt to“drop” when the pulp chamber is reached. If thechamber is well calcified and the “drop” is not felt,vertical penetration is made until the contra-anglehandpiece rests against the occlusal surface. Thisdepth is approximately 9 mm, the position of thefloor of the pulp chamber that lies at the cervicallevel. In removing the bur, the orifice is widenedbuccolingually to twice the width of the bur toallow room for exploration for canal orifices. If asurgical-length bur is used, care must be exercisednot to perforate the furca.

C. An endodontic explorer is used to locate orifices tothe buccal and lingual canals in the first premolaror the central canal in the second premolar.

Tension of the explorer shaft against the walls ofpreparation will indicate the amount and directionof extension necessary.

D. Working from inside the pulp chamber to outside,a round bur is used at low speed to extend the cav-ity buccolingually by removing the roof of the pulpchamber.

E. Buccolingual extension and finish of cavity wallsare completed with a 701 U fissure bur at acceler-ated speed.

F. Final preparation should provide unobstructedaccess to canal orifices. Cavity walls should notimpede complete authority over enlarging instru-ments.

G. Outline form of final preparation will be identicalfor both newly erupted and “adult” teeth.Buccolingual ovoid preparation reflects the anato-my of the pulp chamber and the position of thebuccal and lingual canal orifices. The cavity mustbe extensive enough to allow for instruments andfilling materials needed to enlarge and fill canals.Further exploration at this time is imperative. Itmay reveal the orifice to an additional canal, a sec-ond canal in the second premolar, or a third canalin the first premolar.

PLATE 12

Endodontic Preparation of Maxillary Premolar Teeth

Page 35: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 12

Page 36: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified first premolarwith a large pulp.A radiograph, if exposed slightly from the mesial,will reveal1. mesiodistal width of the pulp2. presence of two pulp canals3. apparently straight canals4. 10-degree distal-axial inclination of the toothThese factors, seen in the radiograph, are borne inmind when preparation is begun. One shouldalways expect two and occasionally three canals.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. height of the pulp horns2. broad buccolingual dimension of the pulp3. two widespread and separate roots, each with a

single straight canal4. 6-degree buccal-axial angulation of the toothThese “unseen” factors will affect the size and shapeof the final preparation. Pulp horns in the roof ofthe pulp chamber are not to be confused with truecanal orifices in the cavity floor. Verticality of thetooth simplifies orientation and bur alignment.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a

young tooth, very wide in the buccolingualdirection. Débridement of the chamber iscompleted in coronal cavity preparation witha round bur. Canal orifices are found well tothe buccal and lingual.

2. Midroot level: the canals are only lightly ovoidand may be enlarged to a round, tapered cavity.

3. Apical third level: the canals are round and areshaped into round, tapered preparations.Preparations terminate at the cementodenti-nal junction, 0.5 to 1.0 mm from the radio-graphic apex.

D. Ovoid coronal preparation need not be as longbuccolingually as the pulp chamber. However, theoutline form must be large enough to provide twofilling points at same time. Buccal and lingual wallssmoothly flow to orifices.

E. Buccal view of an adult first premolar with exten-sive secondary dentin formation. A radiograph willreveal1. full pulp recession and thread-like appearance

of the pulp2. radiographic appearance of only one canal3. 10-degree distal-axial inclination of the toothOwing to misalignment of the bur, perforation ofthe mesiocervical, at the point of mesial indenta-tion, may occur.

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession and a greatly flattened pulp

chamber2. buccolingual width revealing the pulp to be

“ribbon shaped” rather than “thread-like”3. single root with parallel canals and a single

apical foramen4. 6-degree buccal-axial angulation of the tooth

The operator must recognize thata. small canal orifices are found well to the buccal

and lingual and are difficult to locate.b. the direction of each canal is determined only

by exploration with a fine curved instrument.c. a single apical foramen cannot be determined;

therefore, two canals must be managed as twoseparate canals.

d. virtually always there will be two and occa-sionally three canals.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the chamber is very narrow

ovoid, and canal orifices are at the buccal andlingual termination of the floor.

2. Midroot level: the canals are round.3. Apical third level: the canals are round.

H. Ovoid coronal preparation must be more extensivein the buccolingual direction because of parallelcanals. More extensive preparation allows instru-mentation without interference.

PLATE 13

Maxillary First Premolar

Pulp Anatomy and Coronal Preparation

Page 37: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 13

Maxillary First Premolars

Curvature of Roots

Single Double Roots

Length of tooth Canals Direction Root Buccal Palatal

Average Length 21.8 mm One canal 9% Straight 38% 28% 45%Maximum Length 23.8 mm One foramen Distal Curve 37% 14% 14%Minimum Length 18.8 mm Two canals 13% Mesial Curve 0% 0% 0%Range 5 mm One foramen *Buccal Curve 15% 14% 28%

Two canals 72% *Lingual Curve 3% 36% 9%Two foramina Bayonet Curve 0% 8% 0%

Three canals 6%Three foramina

*Not apparent in radiograph

Page 38: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified second premolarwith a large pulp. A radiograph will reveal1. narrow mesiodistal width of the pulp2. apical-distal curvature (34% of the time)3. 19-degree distal-axial inclination of the toothThese factors, seen in the radiograph, are borne inmind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. broad buccolingual width revealing the pulp to

be “ribbon shaped”2. single root with a large single canal3. 9-degree lingual-axial angulation of the toothThe pulp is shown to be a broad “ribbon” ratherthan a “thread” as it appears from radiograph.These “unseen” factors affect the size, shape, andinclination of the final preparation.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, very wide in the buccolingual direction.Débridement of the chamber is completedduring coronal cavity preparation with around bur. The canal orifice is directly in thecenter of the tooth.

2. Midroot level: the canal remains ovoid inshape and requires perimeter filing.

3. Apical third level: the canal, round in shape, isfiled and then shaped into a round, taperedpreparation. Preparation terminates at thecementodentinal junction, 0.5 to 1.0 mm fromthe radiographic apex.

D. Ovoid preparation allows débridement of theentire pulp chamber and funnels down to theovoid midcanal.

E. Buccal view of an adult second premolar with exten-sive secondary dentin formation. A radiograph, ifexposed slightly from the mesial, will reveal

1. pulp recession and the “thread-like” appear-ance of the pulp

2. roentgen appearance of two roots (2% of thetime)

3. bayonet curve of the roots (20% of the time)4. 19-degree distal-axial inclination of the tooth

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. buccolingual width revealing the coronal pulp

to be “ribbon shaped” rather than “thread-like”2. high bifurcation and two separate apical third

roots3. 9-degree lingual-axial angulation of the toothThe operator must recognize thata. small canal orifices are deeply placed in the

root and will be difficult to locate.b. the direction of each canal is determined by

exploration with a fine curved file carried downthe wall until the orifice is engaged. Then, byhalf-rotation, the file is turned to match the firstcurve of the canal, followed by penetration untilthe tip again catches on the curved wall. A sec-ond half-turn and further penetration will carrythe tip of the instrument to within 0.5 to 1.0 mm of the radiographic apex. Retractionwill remove dentin at both curves.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the chamber, very narrow ovoid,

extends deeply into the root.2. Midroot level: the bayonet curve and round

canal orifices are apparent.3. Apical third level: the canals are round. The

severe curve at the “bayonet” is reduced by fil-ing action into a gradual curve.

H. An ovoid coronal cavity is prepared well to themesial of the occlusal surface, with a depth of pen-etration skewed toward the bayonet curvature.Skewing the cavity allows an unrestrainedapproach to the first curve.

PLATE 14

Maxillary Second Premolar

Pulp Anatomy and Coronal Preparation

Page 39: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 14

Maxillary Second Premolars

Length of tooth Canals Curvature

Average Length 21 mm One canal 75% Straight 9.5%Maximum Length 23 mm One foramen Distal Curve 27.0%Minimum Length 19 mm Two canals 24% Mesial Curve 1.6%Range 4 mm Two foramina Buccal Curve 12.7%

Three canals 1% *Lingual Curve 4.0%Bayonet Curve 20.6%

*Not apparent in radiograph

Page 40: Ch10: ENDODONTIC CAVITY PREPARATION

A. UNDEREXTENDED preparation exposing onlypulp horns. Control of enlarging instruments isabdicated to cavity walls. The white color of theroof of the chamber is a clue to a shallow cavity.

B. OVEREXTENDED preparation from a fruitlesssearch for a receded pulp. The enamel walls havebeen completely undermined. Gouging relates tofailure to refer to the radiograph, which clearlyindicates pulp recession.

C. PERFORATION at the mesiocervical indentation.Failure to observe the distal-axial inclination of thetooth led to bypassing receded pulp and perfora-tion. The maxillary first premolar is one of themost commonly perforated teeth.

D. FAULTY ALIGNMENT of the access cavity throughfull veneer restoration placed to “straighten” thecrown of a rotated tooth. Careful examination of theradiograph would reveal the rotated body of the tooth.

E. BROKEN INSTRUMENT twisted off in a“cross-over” canal. This frequent occurrence maybe obviated by extending the internal preparationto straighten the canals (dotted line).

F. FAILURE to explore, débride, and obturate thethird canal of the maxillary first premolar (6% ofthe time).

G. FAILURE to explore, débride, and obturate the sec-ond canal of the maxillary second premolar (24%of the time).

PLATE 15

Maxillary Premolar Teeth

ERRORS in Cavity Preparation

Page 41: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 15

Page 42: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the occlusal sur-face of all posterior teeth. Initial penetration ismade in the exact center of the central groove ofmandibular premolars. The bur is directed parallelto the long axis of the tooth. The 702 U taper fis-sure bur in an accelerated-speed contra-anglehandpiece is ideal for perforating gold casting orvirgin enamel surface to the depth of the dentin.Amalgam fillings are penetrated with a round burin a high-speed contra-angle handpiece.

B. A regular-length No. 4 round bur is used to openvertically into the pulp chamber. The bur will befelt to “drop” when the pulp chamber is reached. Ifthe chamber is well calcified, initial penetration iscontinued until the contra-angle handpiece restsagainst the occlusal surface. This depth of 9 mm isthe usual position of the canal orifice that lies at thecervical level. In removing the bur, the occlusalopening is widened buccolingually to twice thewidth of the bur to allow room for exploration.

C. An endodontic explorer is used to locate the cen-tral canal. Tension of the explorer against the wallsof preparation will indicate the amount and direc-tion of extension necessary.

D. Working from inside the pulp chamber to outside,a regular-length No. 2 or 4 round bur is used toextend the cavity buccolingually by removing theroof of the pulp chamber.

E. Buccolingual extension and finish of cavity wallsare completed with a 702 U fissure bur at acceler-ated speed.

F. Final ovoid preparation is a tapered funnel fromthe occlusal to the canal, providing unobstructedaccess to the canal. No overhanging tooth structureshould impede complete authority over enlarginginstruments.

G. Buccolingual ovoid outline form reflects the anato-my of the pulp chamber and position of the cen-trally located canal. The cavity is extensive enoughto allow for instruments and filling the materialsneeded to enlarge and fill canals. Further explo-ration at this time may reveal the orifice to anadditional canal, especially a second canal in thefirst premolar. The outline form of the final prepa-ration will be identical for both newly erupted and“adult” teeth.

PLATE 16

Endodontic Preparation of Mandibular Premolar Teeth

Pulp Anatomy and Coronal Preparation

Page 43: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 16

Page 44: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified first premolarwith a large pulp. A radiograph, if exposed slightlyfrom the mesial, will reveal:1. narrow mesiodistal width of the pulp2. presence of one pulp canal3. relatively straight canal4. 14-degree distal-axial inclination of the rootAll of these factors, seen in radiograph, are bornein mind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent from the radiograph:1. height of the pulp horn2. broad buccolingual extent of the pulp3. apical-buccal curvature (2% of the time)4. 10-degree lingual-axial angulation of the rootThese “unseen” factors will affect the size, shape,and inclination of the final preparation. Severe api-cal curvature can be detected only by explorationwith a fine curved file. Near-verticality of the toothsimplifies orientation and bur alignment.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is enormous in a young

tooth, very wide in the buccolingual dimen-sion. Débridement of the ovoid chamber iscompleted during coronal cavity preparationwith a round bur.

2. Midroot level: the canal continues ovoid andrequires perimeter filing.

3. Apical third level: the canal, generally round inshape, is enlarged by shaping into a round,tapered preparation. Preparation terminates atthe cementodentinal junction, 0.5 to 1.0 mmfrom the radiographic apex.

D. Ovoid coronal preparation allows débridement ofthe entire pulp chamber, funnels down to the ovoidmidcanal, and is large enough buccolingually to

allow passage of instruments used to enlarge andfill the canal space.

E. Buccal view of an adult first premolar with exten-sive secondary dentin formation. A radiograph willreveal1. pulp recession and “thread-like” appearance of

the pulp2. radiographic appearance of only one canal3. 14-degree distal-axial inclination of the root

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. buccolingual “ribbon-shaped” coronal pulp2. single-root, bifurcated canal at the midroot

level and a single apical foramen3. 10-degree lingual-axial angulation of the root

The operator must recognize thata. small orifices are difficult to locate.b. the presence of a bifurcated canal is determined

only by exploration with a fine curved file.c. a single apical foramen can be determined by

placing instruments in both canals at the sametime. The instruments will be heard and felt tograte against each other.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the chamber is very narrow

ovoid.2. Midroot level: the two branches of the canal

are round.3. Apical third level: the canal is round.Divisions of the canal are enlarged by filing. Thebuccal canal would be filled to the apex and the lin-gual canal to the point where the canals rejoin.

H. Ovoid funnel-shaped coronal preparation must beextensive enough buccolingually to allow forenlarging and filling both canals.

PLATE 17

Mandibular First Premolar

Pulp Anatomy and Coronal Preparation

Page 45: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 17

Mandibular First Premolar

Length of tooth Canals Curvature of root

Average Length 22.1 mm One canal 73.5% Straight 48% †Buccal Curve 2%Maximum Length 24.1 mm One foramen Distal Curve 35% †Lingual Curve 7%Minimum Length 20.1 mm Two canals* 6.5% Mesial Curve 0% Bayonet Curve 7%Range 4.0 mm One foramen

Two canals* 19.5%Two foramina

Three canals 0.5%*Incidence higher in black persons than in white persons

†Not apparent in radiograph

Page 46: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified second premolarwith a large pulp. A radiograph will reveal1. mesiodistal width of the pulp2. apical-distal curvature (40% of the time)3. 10-degree distal-axial inclination of the rootThese factors, seen in the radiograph, are borne inmind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. broad buccolingual “ribbon-shaped” coronal

pulp2. single root with pulpal bifurcation in the apical

third3. 34-degree buccal-axial angulation of the rootThese “unseen” factors affect the size, shape, andinclination of the final preparation. Apical thirdbifurcation, unseen in the radiograph, emphasizesthe necessity of careful canal exploration.

C. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the pulp is large in a young

tooth, very wide in the buccolingual dimen-sion. Débridement of the chamber is complet-ed during coronal cavity preparation with around bur.

2. Midroot level: the canal continues to be longovoid and requires perimeter filing.

3. Apical third level: the canals, generally round,are shaped into round, tapered preparations.Preparation terminates at the cementodentinaljunction, 0.5 to 1.0 mm from the radiographicapex.

D. Ovoid, coronal funnel-shaped preparation allowsdébridement of the entire pulp chamber down tothe ovoid midcanal. The cavity is large enough

buccolingually to allow enlarging and filling ofboth canals.

E. Buccal view of an adult second premolar withextensive secondary dentin formation. A radi-ograph, if exposed slightly from the mesial, willreveal1. pulp recession and “thread-like” appearance of

the pulp2. sweeping distal curve of the apical third of the

root of the tooth (40% of the time)3. 10-degree distal-axial angulation of the root

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. buccolingual “ribbon-shaped” pulp2. minus 34-degree buccal-axial angulation of the

root

The operator should recognize thata. a small canal orifice will be difficult to locate.b. the direction of the canal is best explored with

a fine curved file that is carried to within 0.5 to1.0 mm of the radiographic apex. Retractionwill then remove dentin at the curve.

G. Cross-sections at three levels: 1, cervical; 2, mid-root; and 3, apical third:1. Cervical level: the chamber is very narrow

ovoid.2. Midroot level: the canal is less ovoid.3. Apical third level: the canal is round.The sweeping curve at the apical third is filed to agradual curve.

H. Ovoid funnel-shaped coronal cavity is modest insize and skewed slightly to the mesial, allowingadequate room to instrument and fill the curvedapical third.

PLATE 18

Mandibular Second Premolar

Pulp Anatomy and Coronal Preparation

Page 47: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 18

Mandibular Second Premolars

Length of tooth Canals Curvature of root

Average Length 21.4 mm One canal 85.5% Straight 39% †Lingual Curve 3%Maximum Length 23.7 mm One foramen Distal Curve 40% Bayonet Curve 7%Minimum Length 19.1 mm Two canals* 1.5% Mesial Curve 0% Trifurcation Curve 1%Range 4.6 mm One foramen †Buccal Curve 10%

Two canals* 11.5%Two foramina

Three canals 0.5%*Incidence much higher in black persons than in white persons

†Not apparent in radiograph

Page 48: Ch10: ENDODONTIC CAVITY PREPARATION

A. PERFORATION at the distogingival caused byfailure to recognize that the premolar has tilted tothe distal.

B. INCOMPLETE preparation and possible instru-ment breakage caused by total loss of instrumentcontrol. Use only occlusal access, never buccal orproximal access.

C. BIFURCATION of a canal completely missed,caused by failure to adequately explore the canalwith a curved instrument.

D. APICAL PERFORATION of an invitingly straightconical canal. Failure to establish the exact lengthof the tooth leads to trephination of the foramen.

E. PERFORATION at the apical curvature caused byfailure to recognize, by exploration, buccal curva-ture. A standard buccolingual radiograph will notshow buccal or lingual curvature.

PLATE 19

Mandibular Premolar Teeth

ERRORS in Cavity Preparation

Page 49: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 19

Page 50: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the occlusal sur-face of all posterior teeth. Initial penetration ismade in the exact center of the mesial pit, with thebur directed toward the lingual. The 702 U taper-ing fissure bur in an accelerated-speedcontra-angle handpiece is ideal for perforatinggold casting or virgin enamel surface to the depthof dentin. Amalgam fillings are penetrated with aNo. 4 or 6 round bur operating in a slow-speedcontra-angle handpiece.

B. According to the size of the chamber, aregular-length No. 4 round bur is used to open intothe pulp chamber. The bur should be directedtoward the orifice of the palatal canal or towardthe mesiobuccal canal orifice, where the greatestspace in the chamber exists. It will be felt to “drop”when the pulp chamber is reached. If the chamberis well calcified, initial penetration is continueduntil the contra-angle rests against the occlusalsurface. This depth of 9 mm is the usual position ofthe floor of the pulp chamber, which lies at the cer-vical level. Working from inside out, back towardthe buccal, the bur removes enough roof of thepulp chamber for exploration.

C. An endodontic explorer is used to locate orifices ofthe palatal, mesiobuccal, and distobuccal canals.Tension of the explorer against the walls of prepa-ration will indicate the amount and direction ofextension necessary. Orifices of canals form theperimeter of preparation. Special care must betaken to explore for a second canal in themesiobuccal root.

D. Again, working at slow speed from inside to out-side, a round bur is used to remove the roof of thepulp chamber. Internal walls and floor of prepara-tion should not be cut into unless difficulty isencountered in locating orifices. In that case, surgi-cal-length No. 2 round burs are necessary toexplore the floor of the chamber.

E. Final finish and funneling of cavity walls are com-pleted with a 702 U fissure bur or tapered diamondpoints at accelerated speed.

F. Final preparation provides unobstructed access tocanal orifices and should not impede completeauthority of enlarging instruments. Improve easeof access by “leaning” the entire preparationtoward the buccal, for all instrumentation is intro-duced from the buccal. Notice that the preparationextends almost to the height of the buccal cusps.The walls are perfectly smooth, and the orifices arelocated at the exact pulpal-axial angles of the cavi-ty floor.

G. Extended outline form reflects the anatomy of thepulp chamber. The base is toward the buccal andthe apex is to the lingual, with the canal orificepositioned at each angle of the triangle. The cavityis entirely within the mesial half of the tooth andneed not invade the transverse ridge but is exten-sive enough, buccal to lingual, to allow positioningof instruments and filling materials. Outline formof final preparation is identical for both a newlyerupted and an “adult” tooth. Note the orifice tothe fourth canal.

PLATE 20

Endodontic Preparation of Maxillary Molar Teeth

Page 51: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 20

Page 52: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified first molar withlarge pulp. A radiograph will reveal1. large pulp chamber2. mesiobuccal root with two separate canals, dis-

tobuccal, and palatal roots, each with one canal3. slightly curved buccal roots4. slightly curved palatal root5. vertical axial alignment of the toothThese factors, seen in radiograph, are borne in mindwhen preparation is begun. Care must be taken toexplore for an additional mesiobuccal canal.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. buccolingual width of the pulp chamber2. apical-buccal curvature of the palatal root

(55% of the time)3. buccal inclination of buccal roots4. vertical axial alignment of the toothThese “unseen” factors will affect the size, shape,and inclination of the final preparation. Sharpbuccal curvature of the palatal canal requires greatcare in exploration and instrumentation. Canalsmust be carefully explored with fine curved files.Enlargement of buccal canals is accomplished byreaming and filing and of the palatal canal bystep-back filing.

C. Cross-section at two levels: 1, cervical; and 2, apicalthird:1. Cervical level: the pulp is enormous in a young

tooth. Débridement of a triangular chamber iscompleted with a round bur. A dark cavityfloor with “lines” connecting orifices is inmarked contrast to white walls. A palatal canalrequires perimeter filing.

2. Apical third level: the canals are essentiallyround. Buccal canals are shaped into round,tapered preparations. Preparations terminateat the cementodentinal junction, 0.5 to 1.0 mmfrom the radiographic apex.

D. Triangular outline form, with the base toward thebuccal and the apex toward the lingual, reflects theanatomy of the pulp chamber, with the orificepositioned at each angle of the triangle. Both buc-cal and lingual walls slope buccally. Mesial and dis-tal walls funnel slightly outward. The cavity isentirely within the mesial half of the tooth and

should be extensive enough to allow positioning ofinstruments and filling materials needed to enlargeand fill canals. The orifice to an extra middlemesial canal may be found in the groove near themesiobuccal canal.

E. Buccal view of an adult first molar with extensive sec-ondary dentin formation. A radiograph will reveal1. pulp recession and “thread-like” pulp2. mesiobuccal, distobuccal, and palatal roots,

each with one canal3. straight palatal root, apical curve, distal root4. apical-distal curvature of the mesial root (78%

of the time)5. vertical axial alignment of the tooth

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession2. relatively straight palatal root3. buccal inclination of the buccal roots4. vertical axial alignment of the tooth

The operator must recognize thata. careful exploration for orifices and canals is

imperative.b. severe curvature of buccal roots will require

careful enlargement with curved instruments.

G. Cross-section at two levels: 1, cervical; and 2, apicalthird:1. Cervical level: a triangular chamber constrict-

ed from secondary dentin formation is débrid-ed during coronal cavity preparation with around bur. Round palatal and distobuccalcanals will be shaped to a round, taperedpreparation.

2. Apical third level: the canals are round. Acurved mesiobuccal canal is enlarged bystep-back filing. Preparations terminate at thecementodentinal junction, 0.5 to 1.0 mm fromthe radiographic apex.

H. Triangular outline form reflects the anatomy of thepulp chamber. Both buccal and lingual walls slopebuccally. The mesial wall slopes mesially to allowfor instrumentation of a severely curved mesiobuc-cal canal. If an additional canal is found in themesiobuccal root, its orifice will usually be in thegroove leading to the palatal canal.

PLATE 21

Maxillary First Molar

Pulp Anatomy and Coronal Preparation

Page 53: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 21

Maxillary First Molars

Curvature of roots

Length of Tooth Mesiobuccal Distobuccal Palatal Canal Direction Palatal Mesial Distal Canals in the mesiobuccal root

Average Length 19.9 mm 19.4 mm 20.6 mm Three canals 41.1% Straight 40% 21% 54% One canal 41.1%Maximum Length 21.6 mm 21.2 mm 22.5 mm Four canals 56.5% Distal Curve 1% 78% 17% One foramenMinimum Length 18.2 mm 17.6 mm 17.6 mm Five canals 2.4% Mesial Curve 4% 0% 19% Two canals 40%Range 3.4 mm 3.6 mm 3.8 mm *Buccal Curve *55% 0% 0% One foramen

*Lingual Curve 0% 0% 0% Two canals 18.9%Bayonet Curve 0% 1% 10% Two foramina

*Not apparent in radiograph

Page 54: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified second molarwith a large pulp. A radiograph will reveal1. large pulp chamber2. mesiobuccal, distobuccal, and palatal roots,

each with one canal3. gradual curvature of all three canals4. vertical axial alignment of the toothThese factors, seen in radiograph, are borne inmind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. buccolingual width of the pulp chamber2. gradual curvature in two directions of all three

canals3. buccal inclination of the buccal roots4. vertical axial alignment of the toothThese “unseen” factors will affect the size, shape,and inclination of the final preparation.

C. Cross-section at two levels: 1, cervical; and 2, apicalthird:1. Cervical level: the pulp is enormous in a young

tooth. Débridement of a triangular chamber iscompleted with round burs. The dark cavityfloor with “lines” connecting orifices is inmarked contrast to white walls.

2. Apical third level: the canals are essentiallyround and are shaped into a round, taperedpreparation. Preparations terminate at thecementodentinal junction, 0.5 to 1.0 from theradiographic apex.

D. Triangular outline form is “flattened” as it reflectsthe internal anatomy of the chamber. Note that thedistobuccal canal orifice is nearer the center of thecavity floor. The entire preparation sharply slopes

to the buccal and is extensive enough to allow posi-tioning of instruments and filling materials neededto enlarge and fill canals.

E. Buccal view of an adult second molar with exten-sive secondary dentin formation.A radiograph will reveal1. pulp recession and “thread-like” pulp2. anomalous appearance of only one root and

two canals3. vertical axial alignment of the tooth

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession2. anomalous appearance of only one root and

two canals3. sweeping curvature of the lingual canal4. vertical axial alignment of the tooth

The operator must recognize thata. canal orifices are difficult to find by explo-

ration.b. a detailed search must be made for the third

canal.

G. Cross-sections at two levels: 1, cervical; and 2, api-cal third.1. Cervical level: ovoid pulp chamber is débrided

during cavity preparation with a round bur.2. Apical third level: canals are round. Preparations

terminate at the cementodentinal junction, 0.5to 1.0 mm from the radiographic apex.

H. Ovoid outline form reflects the internal anatomy ofthe pulp chamber and elongated parallelogramshape of the occlusal surface. The entire prepara-tion slopes sharply to the buccal.

PLATE 22

Maxillary Second Molar

Pulp Anatomy and Coronal Preparation

Page 55: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 22

Maxillary Second Molars

Curvature of roots

Length of Tooth Mesiobuccal Distobuccal Palatal Number of Roots Direction Palatal Mesial Distal Canals in the mesiobuccal root

Average Length 20.2 mm 19.4 mm 20.8 mm Three 54% Straight 63% 22% 54% One canal 63%Maximum Length 22.2 mm 21.3 mm 22.6 mm Fused 46% Distal 0% 54% ? One foramenMinimum Length 18.2 mm 17.5 mm 19.0 mm Mesial 0% 0% 17% Two canals 13%Range 4.0 mm 3.8 mm 3.6 mm *Buccal 37% One foramen

Lingual 0% Two canals 24%Two foramina

*Not apparent in radiograph

Page 56: Ch10: ENDODONTIC CAVITY PREPARATION

A. UNDEREXTENDED preparation. Pulp horns havemerely been “nicked,” and the entire roof of thepulp chamber remains. “White” color dentin of theroof is a clue to underextension (A1). Instrumentcontrol is lost.

B. OVEREXTENDED preparation underminingenamel walls. The crown is badly gouged owing tofailure to observe pulp recession in the radiograph.

C. PERFORATION into furca using a surgical-lengthbur and failing to realize that the narrow pulpchamber had been passed. Operator error in failureto compare the length of the bur to the depth of thepulp canal floor. Length should be marked on thebur shank with Dycal.

D. INADEQUATE vertical preparation related to fail-ure to recognize severe buccal inclination of anunopposed molar.

E. DISORIENTED occlusal outline form exposing onlythe palatal canal. A faulty cavity has been prepared infull crown, which was placed to “straighten” a rotat-ed molar (E1). Palpating for mesiobuccal rootprominence would reveal the severity of the rotation.

F. LEDGE FORMATION caused by using a largestraight instrument in a curved canal.

G. PERFORATION of a palatal root commonlycaused by assuming the canal to be straight andfailing to explore and enlarge the canal with a finecurved instrument.

PLATE 23

Maxillary Molar Teeth

ERRORS in Cavity Preparation

Page 57: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 23

Page 58: Ch10: ENDODONTIC CAVITY PREPARATION

A. Entrance is always gained through the occlusal sur-face of all posterior teeth. Initial penetration is madein the exact center of the mesial pit, with the burdirected toward the distal. The 702 U tapering fis-sure bur in an accelerated-speed contra-angle hand-piece is ideal for perforating gold casting or virginenamel surface to the depth of dentin. Amalgam fill-ings are penetrated with a No. 4 round bur operat-ing in a high-speed contra-angle handpiece.

B. According to the size of the chamber, a regular-lengthNo. 4 or 6 round bur is used to open into the pulpchamber. The bur should be directed toward the ori-fice of the mesiobuccal or distal canal, where thegreatest space in the chamber exists. It will be felt to“drop” when the pulp chamber is reached. If thechamber is well calcified, initial penetration is con-tinued until the contra-angle handpiece rests againstthe occlusal surface. This depth of 9 mm is the usualposition of the floor of the pulp chamber, which liesat the cervical level. Working from inside out, backtoward the mesial, the bur removes enough roof ofthe pulp chamber for exploration.

C. An endodontic explorer is used to locate orifices ofthe distal, mesiobuccal, and mesiolingual canals.Tension of the explorer against the walls of prepa-ration indicates the amount and direction of exten-sion necessary. Orifices of the canals form theperimeter of preparation. Special care must betaken to explore for an additional canal in the dis-tal root. The distal canal should form a trianglewith two mesial canals. If it is asymmetric, alwayslook for the fourth canal 29% of the time.

D. Again, working at slow speed from the inside tooutside, a round bur is used to remove the roof ofthe pulp chamber. Internal walls and floor ofpreparation should not be cut into unless difficul-ty is encountered in locating orifices. In that case,surgical-length No. 2 or 4 round burs are necessaryto explore the floor of the chamber.

E. Final finish and funneling of cavity walls are com-pleted with a 702 U fissure bur or diamond pointat accelerated speed.

F. Final preparation provides unobstructed access tocanal orifices and should not impede the completeauthority of enlarging instruments. Improve easeof access by “leaning” the entire preparationtoward the mesial, for all instrumentation is intro-duced from the mesial. Notice that the cavity out-line extends to the height of the mesial cusps. Thewalls are perfectly smooth and the orifices locatedat the exact pulpal-axial angle of the cavity floor.

G. “Square” outline form reflects the anatomy of thepulp chamber. Both mesial and distal walls slopemesially. The cavity is primarily within the mesialhalf of the tooth but is extensive enough to allowpositioning of the instrument and filling materi-als. The outline form of the final preparation willbe identical for both a newly erupted and an“adult” tooth. Further exploration should deter-mine if a fourth canal can be found in the distal. Ifso, the outline is extended in that direction. In thatcase, an orifice will be positioned at each angle ofthe square.

PLATE 24

Endodontic Preparation of Mandibular Molar Teeth

Page 59: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 24

Page 60: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified first molar withlarge pulp. The initial radiograph will reveal1. large pulp chamber2. mesial and distal roots, each apparently con-

taining one canal3. vertical distal root with a severe apical curvature4. curvature of the mesial root (84% of the time)5. distal-axial inclination of the toothThese factors, seen in radiograph, are borne inmind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. single mesial root with two canals2. minus 58-degree buccal-axial inclination of

the rootsAll of these unseen factors will affect the size,shape, and inclination of the final preparation.

C. Cross-section at three levels: 1, cervical; 2, midroot;and 3, apical third:1. Cervical level: the pulp, enormous in a young

tooth, is débrided during coronal cavity prepa-ration with a round bur.

2. Midroot level: the canals are ovoid. Severeindentation on the distal surface of the mesialroot brings the canal within 1.5 mm of theexternal surface, an area frequently perforatedby “stripping.”

3. Apical third level: the canals are round and areshaped into round, tapered preparations.Preparations terminate at the cementodentinaljunction, 0.5 to 1.0 mm from the radiographicapex.

D. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. height of distal pulp horns2. “ribbon-shaped” distal canal

E. Buccal view of an adult first molar with extensivesecondary dentin formation. A radiograph will reveal1. pulp recession and “thread-like” pulp2. mesial and distal roots, each apparently con-

taining one canal3. mesial curvature of the distal root (5% of the

time) and distal curvature of the mesial root(84% of the time)

4. distal-axial inclination of the tooth

F. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession2. mesial root, two canals, and a single foramen3. minus 58-degree buccal-axial inclination of

the roots

The operator must recognize thata. careful exploration with two instruments at the

same time reveals a common apical foramen.b. mesial canals curve in two directions.

G. Cross-section at three levels: 1, cervical; 2, midroot;and 3, apical third:1. Cervical level: the chamber is débrided during

coronal cavity preparation with a round bur.2. Midroot level: the canals are nearly round and

are enlarged during reaming of an apical third.3. Apical third level: the canals are round and are

shaped into a round, tapered preparation.Preparations terminate at the cementodentinaljunction, 0.5 to 1.0 mm from the radiographicapex.

H. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession2. distal root with the usual single canal3. buccal-axial inclination of the roots4. distal canal curves in two directions

The operator should recognize thata. the presence of a fourth canal can be deter-

mined only by careful exploration.

I. Triangular outline form reflects the anatomy ofthe pulp chamber. Both mesial and distal wallsslope mesially. The cavity is primarily within themesial half of the tooth but is extensive enough toallow positioning of instruments and filling mate-rials. Further exploration should determinewhether a fourth canal can be found in the distal.In that case, an orifice will be positioned at eachangle of the rhomboid.

PLATE 25

Mandibular First Molar

Pulp Anatomy and Coronal Preparation

Page 61: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 25

Mandibular First Molars

Length ofCanals Curvature of Roots

Tooth Mesial Distal Roots Canals Mesial Distal Direction Mesial Distal

Average 20.9 mm 20.9 mm Two roots 97.8% Two canals 6.7% Two canals 40.5% One canal 71.1% Straight 16% 74%Length One foramen Distal 84% 21%

Maximum 22.7 mm 22.6 mm Three roots 2.2% Three canals 64.4% Two canals Two canals 28.9% Mesial 0% 5%Length Two foramina 59.5% Buccal 0% 0%

Minimum 19.1 mm 19.2 mm Four canals 28.9% Two canals 61.5% Lingual 0% 0%Length One foramen

Range 3.6 mm 3.4 mm Two canals 38.5%Two foramina

Page 62: Ch10: ENDODONTIC CAVITY PREPARATION

A. Buccal view of a recently calcified second molarwith a large pulp. A radiograph will reveal1. large pulp chamber2. mesial and distal roots, each apparently con-

taining one canal3. mesial curvature of the distal root (10%)4. bayonet curvature of the mesial root (7%)5. distal-axial inclination of the toothThese factors, seen in radiograph, are borne inmind when preparation is begun.

B. Mesial view of the same tooth demonstratingdetails not apparent in the radiograph:1. mesial root with two canals2. lingual curvature of the mesiobuccal canal3. “S” curvature of the mesiolingual canal4. minus 52-degree buccal-axial inclination of

the rootsThese unseen factors will affect the size, shape, andinclination of the final preparation. Canals must becarefully explored with a fine curved file. The dou-ble “S” curvature of the mesiolingual canal is espe-cially challenging. All three canals are enlarged bystep-back or step-down filing.

C. Cross-section at three levels: 1, cervical; 2, midroot;and 3, apical third:1. Cervical level: the pulp, enormous in a young

tooth, is débrided during coronal cavity prepa-ration with a round bur.

2. Midroot level: the canals are ovoid. Carefullyavoid filing against the distal surface of themesial root, where “stripping” perforationoften occurs.

3. Apical third level: the canals are round and areshaped into round, tapered preparations.Preparations terminate at the cementodentinaljunction, 0.5 to 1.0 mm from the radiographicapex.

D. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. height of the distal pulp horns2. “ribbon-shaped” distal canal

E. Buccal view of an adult second molar with exten-sive secondary dentin formation. A radiograph willreveal:

1. pulp recession and a “thread-like” pulp2. mesial and distal roots, each apparently con-

taining one canal3. “straight” distal root (58%) and distal curva-

ture of the mesial root (84%)4. distal-axial inclination of the tooth

F. Mesial view of the same tooth demonstratingdetails not apparent in the original radiograph:1. pulp recession2. mesial root with two canals that join and “cross

over”3. minus 52-degree buccal-axial inclination of

the roots

The operator should recognize thata. careful exploration with curved instruments is

imperative.b. mesial canals curve in two directions.

G. Cross-section at three levels: 1, cervical; 2, midroot;and 3, apical third:1. Cervical level: the chamber is débrided during

coronal cavity preparation with a round bur.2. Midroot level: the canals, only slightly ovoid in

shape, will be enlarged by step-back filing ofthe apical third of the canals.

3. Apical third level: the canals are round and areshaped into round, tapered preparations.Preparations terminate at the cementodentinaljunction, 0.5 to 1.0 mm from the radiographicapex.

H. Distal view of the same tooth demonstratingdetails not apparent in the radiograph:1. pulp recession2. single distal root with a usual single canal3. buccal-axial inclination of the tooth

I. Triangular outline form reflects the anatomy ofthe pulp chamber. Both mesial and distal wallsslope mesially. The cavity is primarily within themesial half of the tooth but is extensive enough toallow positioning of instruments and filling mate-rials. Further exploration should determinewhether a fourth canal can be found in the distal.In that case, an orifice will be found at each angleof the rhomboid.

PLATE 26

Mandibular Second Molar

Pulp Anatomy and Coronal Preparation

Page 63: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 26

Mandibular Second Molars

Curvature of rootsCanals

Single Double Root

Length of Tooth Mesial Distal Mesial Distal Direction Root Mesial Distal

Average Length 20.9 mm 20.8 mm One canal 13% 92% Straight 53% 27% 58%Maximum Length 22.6 mm 22.6 mm One foramen Distal Curve 26% 61% 18%Minimum Length 19.2 mm 19.0 mm Two canals 49% 5% Mesial Curve 0% 0% 10%Range 3.4 mm 3.6 mm One foramen *Buccal Curve 0% 4% 4%

Two canals 38% 3% *Lingual Curve 2% 0% 0%Two foramina Bayonet Curve 19% 7% 6%

*Not apparent in radiograph

Page 64: Ch10: ENDODONTIC CAVITY PREPARATION

A. OVEREXTENDED preparation underminingenamel walls. The crown is badly gouged owing tofailure to observe pulp recession in the radiograph.

B. PERFORATION into furca caused by using alonger bur and failing to realize that the narrowpulp chamber had been passed. The bur should bemeasured against the radiograph and the depth tothe pulpal floor marked on the shaft with Dycal.

C. PERFORATION at the mesial-cervical caused byfailure to orient the bur with the long axis of themolar severely tipped to the mesial.

D. DISORIENTED occlusal outline form exposingonly the mesiobuccal canal. A faulty cavity hasbeen prepared in full crown, which was placed to“straighten up” a lingually tipped molar (D1).

E. FAILURE to find a second distal canal owing tolack of exploration for a fourth canal.

F. LEDGE FORMATION caused by faulty explo-ration and using too large of an instrument.

G. PERFORATION of the curved distal root causedby using a large straight instrument in a severelycurved canal.

PLATE 27

Mandibular Molar Teeth

ERRORS in Cavity Preparation

Page 65: Ch10: ENDODONTIC CAVITY PREPARATION

PLATE 27

Page 66: Ch10: ENDODONTIC CAVITY PREPARATION

RADICULAR CAVITY PREPARATION

Objectives

With the completion of the coronal access cavity,preparation of the radicular cavity may be started.Root canal preparation has two objectives: thoroughdébridement of the root canal system and the specificshaping of the root canal preparation to receive a spe-cific type of filling. A major objective, of course, is thetotal obturation of this designed space. The ultimateobjective, however, should be to create an environmentin which the body’s immune system can produce heal-ing of the apical periodontal attachment apparatus.

Cleaning and Débridement of the Root Canal

The first objective is achieved by skillful instrumentationcoupled with liberal irrigation. This double-prongedattack will eliminate most of the bacterial contaminantsof the canal as well as the necrotic debris and dentin.46

In addition to débridement, remaining bacteria havelong been controlled by intracanal medication. This isstill true today even though many dentists, as well asendodontists, merely seal a dry cotton pellet in thechamber in multiappointment cases. This practice can-not be recommended, and the reader is urged to readchapter 2, which deals in detail with the importance of

470 Endodontics

intracanal medication. Single-appointment treatment,of course, precludes interappointment medication.

Cleaning and sanitizing the root canal have beenlikened to the removal of carious dentin in a restorativepreparation—that is, enough of the dentin wall of thecanal must be removed to eliminate the attachednecrotic debris and, insofar as possible, the bacteria anddebris found in the dentinal tubuli (Figure 10-8). Alongwith repeated irrigation, the débriding instrumentsmust be constantly cleaned. A sterile 2 × 2 gauze squaresoaked in alcohol is used to wipe the instruments.47

Preparing the Root Canal

Over the years, two different approaches to root canalcleaning and shaping have emerged: the “step-back”and the “step-down” preparations. The step-backpreparation is based upon the traditional approach:beginning the preparation at the apex and workingback up the canal coronally with larger and largerinstruments. The step-down preparation, often called“the crown-down approach,” begins coronally and thepreparation is advanced apically, using smaller andsmaller instruments, finally terminating at the apicalstop. All of the techniques of canal cleaning and shap-ing, including those modified by new instruments ordevices, will use variations of either a step-back or a

Figure 10-8 A, Cross-section through pulp canal showing ideal round preparation to remove canal debris and enough dentin to eliminatevirtually all bacteria in the tubuli. B, Serial section showing necrotic canal contents and debris-saturated dentin. Débridement of necroticmass and instrumentation of the dentin to the black line are the goals of instrumentation.

A B

Page 67: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 471

step-down approach. In either event, certain principlesof cavity preparation (in this case, radicular and coro-nal) must be followed to ensure thorough cleaning andproper shaping for obturation.

Principles

Once again, as expounded for coronal cavity prepara-tion, a return to Black’s Principles of Cavity Preparationis in order.1 The root canal “cavity” is prepared with thesame principles in mind:

• Outline Form• Convenience Form• Toilet of the cavity• Retention Form• Resistance Form• Extension for prevention

Figure 10-9 repeats the entire endodontic cavitypreparation, from Outline Form beginning at theenamel’s edge to Resistance Form at the apical fora-

men. In some preparations, Retention Form may bedeveloped in the last 2 to 3 mm of the apical canal.Usually, however, the preparation is a continuoustapered preparation from crown to root end.

The entire length of the cavity falls under the rubricOutline Form and toilet of the cavity. At the coronalmargin of the cavity, the Outline Form must be con-tinually evaluated by monitoring the tension of theendodontic instruments against the margins of the cav-ity. Remember to retain control of the instruments;they must stand free and clear of all interference. Accessmay have to be expanded (Convenience Form) ifinstruments start to bind, especially as larger, less flexi-ble instruments are used.

The size and shape of the entire preparation will begoverned by the anatomy of the root canal. One attemptsto retain this basic shape while thoroughly cleaning andflaring to accommodate the instruments and fillingmaterials used in débridement and obturation.

The entire preparation, crown to apex, may be con-sidered extension for prevention of future periradicu-lar infection and inflammation.

Outline Form and Toilet of the Cavity

Meticulous cleaning of the walls of the cavity until theyfeel glassy-smooth, accompanied by continuous irriga-tion, will ensure, as far as possible, thorough débride-ment. One must realize, however, that total débride-ment is not possible in some cases, that some “nooksand crannies” of the root canal system are virtuallyimpossible to reach with any device or system.48 Onedoes the best one can, recognizing that in spite ofmicroscopic remaining debris, success is possible.Success depends to a great extent on whether unreach-able debris is laden with viable bacteria that have asource of substrate (accessory canal or microleakage)to survive—hence the importance of thorough douch-ing through irrigation, toilet of the cavity.49

Retention Form

In some filling techniques, it is recommended that theinitial primary gutta-percha point fit tightly in the apical2 to 3 mm of the canal. These nearly parallel walls(Retention Form) ensure the firm seating of this princi-pal point. Other techniques strive to achieve a continu-ously tapering funnel from the apical foramen to thecavosurface margin. Retention Form in these cases isgained with custom-fitted cones and warm compactiontechniques.

These final 2 to 3 mm of the cavity are the most cru-cial and call for meticulous care in preparation. This iswhere the sealing against future leakage or percolation

Figure 10-9 Concept of total endodontic cavity preparation,coronal and radicular as a continuum, based on Black’s principles.Beginning at apex: A, Radiographic apex. B, Resistance Form,development of “apical stop” at the cementodentinal junctionagainst which filling is to be compacted and to resist extrusion ofcanal debris and filling material. C, Retention Form, to retain pri-mary filling point. D, Convenience Form, subject to revision asneeded to accommodate larger, less flexible instruments. Externalmodifications change the Outline Form. E, Outline Form, basicpreparation throughout its length dictated by canal anatomy.

Page 68: Ch10: ENDODONTIC CAVITY PREPARATION

into the canal takes place. This is also the region whereaccessory or lateral canals are most apt to be present.

Coronally, from the area of retention, the cavitywalls are deliberately flared. The degree of flare willvary according to the filling technique to be used—lat-eral compaction with cold or warm gutta-percha orvertical compaction of heat-softened gutta-percha.

Resistance Form

Resistance to overfilling is the primary objective ofResistance Form. Beyond that, however, maintainingthe integrity of the natural constriction of the apicalforamen is a key to successful therapy. Violating thisintegrity by overinstrumentation leads to complica-tions: (1) acute inflammation of the periradicular tis-sue from the injury inflicted by the instruments or bac-teria and/or canal debris forced into the tissue, (2)chronic inflammation of this tissue caused by the pres-ence of a foreign body—the filling material forcedthere during obturation, and (3) the inability to com-pact the root canal filling because of the loss of the lim-iting apical termination of the cavity—the importantapical stop. This could be compared to an attempt toplace a Class II amalgam filling without the limitingpresence of a proximal matrix band.

Establishing Apical Patency

Bearing in mind that canal preparations should ter-minate at the dentinocemental junction, slightlyshort of the apex, one is left with a tiny remainingportion of the canal that has not been properlycleaned and may contain bacteria and packed debris.It is this section of the canal that is finally cleaned,not shaped, with fine instruments—No. 10 or 15 files.This action is known as establishing apical patency. Itshould not be confused with overenlargement—destroying the apical foramen. Cailleteau andMullaney surveyed all dental schools in the UnitedStates to determine the prevalence of teaching apicalpatency. They found that 50% of the 49 schoolsresponding teach the concept.50

In some cases—youngsters, root fractures, apical rootresorption—the apical foramen is open, and these casesalways present difficulties in instrumentation and obtu-ration. Special techniques, to be discussed later, havebeen devised to overcome the loss of resistance form.

In Mexico, Kuttler has shown that the narrowest waistof the apical foramen often lies at the dentinocementaljunction (Figure 10-10).51 He established this point atapproximately 0.5 mm from the outer surface of the rootin most cases. The older the patient, however, the greaterthis distance becomes because continued cemental for-

472 Endodontics

mation builds up the apex. One is also reminded that thedentinocemental junction, where Resistance Form maybe established, is the apical termination of the pulp.Beyond this point, one is dealing with the tissues of theperiodontal ligament space, not the pulp.

The fact must also be established that the apicalforamen does not always lie at the exact apex of theroot. Most often, canals exit laterally, short of the radi-ographic apex. This may be revealed by careful scrutinyof the film with a magnifying glass or by placing acurved exploratory instrument to the exact canallength and repeating the radiograph examination.Japanese researchers reported from a native cohort thatthe apical foramen exits the exact apex only 16.7% ofthe time in maxillary anterior teeth.52

Extension for Prevention

Seidler once described the ideal endodontic cavity as around, evenly tapered space with a minimal opening atthe foramen.53 Because one is working with round,tapered materials, one would think that this ideal is eas-ily achieved, particularly when one thinks of rootcanals as naturally round and tapered. As seen in theanatomic drawings in this chapter, however, few canalsare round throughout their length. Thus, one mustusually compromise from the ideal, attempting to pre-pare the round, tapered cavity but knowing that fillingtechniques must be used to make up for the variancefrom ideal. This is why single-point fillings, whethersilver or gutta-percha, are seldom used.

The extension of the cavity preparation through-out its entire length and breadth is necessary, howev-er, to ensure prevention of future problems.Peripheral enlargement of the canal, to remove all ofthe debris, followed by total obturation is the primarypreventive method.

Figure 10-10 Instruments and filling material should terminateshort of the cementodentinal junction, the narrowest width of thecanal, and its termination at the foramen. This point is often 0.5 to1.0 mm from the apex.

Page 69: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 473

INSTRUMENTS AND METHODS FOR RADICU-LAR CLEANING AND SHAPING

Before launching into a detailed or even a broad dis-cussion of the methods and shapes of canal cavitypreparation, a description of the instruments andmethods used in cleaning and shaping the canal is nec-essary. “The order of their appearance” during prepa-ration will also be discussed: basic endodontic instru-ments, irrigation, exploration for canal orifices, explo-ration of the canal, and length of tooth determination.Then the techniques of intraradicular cavity prepara-tion will follow in detail. Pulpectomy is discussed later.

Basic Endodontic Instruments

After years of relative inactivity, a remarkable upsurge inendodontic instrument design and refinement hasrecently developed. Historically, very little was done toimprove the quality or standardization of instrumentsuntil the 1950s, when two research groups startedreporting on the sizing, strength, and materials thatwent into hand instruments.54–57 After the introductionof standardized instruments,57 about the only changesmade were the universal use of stainless rather than car-bon steel and the addition of smaller (Nos. 6 and 8) andlarger (No. 110 to 140) sizes as well as color coding andthe re-emergence of power-driven instruments.

By 1962, a working committee on standardization hadbeen formed including manufacturers, the AmericanAssociation of Endodontists (AAE), and the AmericanDental Association (ADA). This group evolved into thepresent-day International Standards Organization (ISO).It was not until 1976, however, that the first approvedspecification for root canal instruments was published(ADA Specification No. 28), 18 years after Ingle andLevine first proposed standardization in 1958.56

Endodontic Instrument Standardization

Before 1958, endodontic instruments were manufac-tured without benefit of any established criteria.Although each manufacturer used what seemed to be aunified size system, the numbering (1 through 6) wasentirely arbitrary. An instrument of one companyrarely coincided with a comparable instrument ofanother company. In addition, there was little unifor-mity in quality control or manufacture, no uniformityexisted in progression from one instrument size to thenext, and there was no correlation of instruments andfilling materials in terms of size and shape.

Beginning in 1955, a serious attempt was made tocorrect these abuses, and in 1959, a new line of stan-dardized instruments and filling material was intro-duced to the profession56:

1. A formula for the diameter and taper in each size ofinstrument and filling material was agreed on.

2. A formula for a graduated increment in size fromone instrument to the next was developed.

3. A new instrument numbering system based oninstrument metric diameter was established.

After initial resistance by many manufacturers, who feltthat the change would entail a “considerable investment innew dies and machinery to produce them,” all manufac-turers, worldwide, eventually accepted the new sizing.

This numbering system, last revised in 2002,58 usingnumbers from 6 to 140, was not just arbitrary but wasbased on the diameter of the instruments in hun-dredths of a millimeter at the beginning of the tip ofthe blades, a point called D0 (diameter 1) (Figure 10-11), and extending up the blades to the most coronalpart of the cutting edge at D16 (diameter 2)—16 mmin length. Additional revisions are under way to coverinstruments constructed with new materials, designs,and tapers greater than 0.02 mm/mm.

At the present time, instruments with a taper greaterthan the ISO 0.02 mm/mm have become popular: 0.04,

Figure 10-11 Original recommendation for standardized instru-ments. Cutting blades 16 mm in length are of the same size andnumbers as standardized filling points. The number of the instru-ment is determined by diameter size at D1 in hundredths of mil-limeters. Diameter 2 (D2) is uniformly 0.32 mm greater than D1.Reproduced with permission from Ingle JI. In: Grossman LI, editor.Transactions of the Second International Conference onEndodontics. Philadelphia: University of Pennsylvania; 1958. p. 123.

Page 70: Ch10: ENDODONTIC CAVITY PREPARATION

0.06, and 0.08. This means that for every millimetergain in the length of the cutting blade, the width(taper) of the instrument increases in size by 0.04, 0.06,and 0.08 of a millimeter rather than the ISO standardof 0.02 mm/mm. These new instruments allow forgreater coronal flaring than the 0.02 instruments.

In contrast to these widened-flare files, a number ofmanufacturers have issued half sizes in the 0.02 flare—2.5, 17.5, 22.5, 27.5, 32.5, and 37.5—to be used in shap-ing extremely fine canals.

The full extent of the shaft, up to the handle, comesin three lengths: standard, 25 mm; long, 31 mm; andshort, 21 mm. The long instruments are often neces-sary when treating canines over 25 mm long. Shorterinstruments are helpful in second and third molars orin the patient who cannot open widely. Other speciallengths are available, such as the popular 19 mminstrument.

Ultimately, to maintain these standards, the AAEurged the ADA and the United States Bureau ofStandards to appoint a committee for endodonticinstrument standardization. A committee was formedand, after considerable work and several drafts, pro-duced a specification package that slightly modifiedand embellished Ingle’s original standardization.57

These pioneering efforts reached international propor-tions when a worldwide collaborative committee wasformed: the ISO, consisting of the Fédération DentaireInternational, the World Health Organization, and theADA Instrument Committee. The ISO has now formu-lated international specifications using the ADA pro-posal as a model.

In 1989, the American National Standards Institute(ANSI) granted approval of “ADA Specification No. 28

474 Endodontics

for endodontic files and reamers” (Figure 10-12). Itestablished the requirements for diameter, length,resistance to fracture, stiffness, and resistance to corro-sion. It also included specifications for sampling,inspection, and test procedures.58 The revision to ADASpecification No. 28 for K-type files and reamers high-lighted 30 years of work to achieve international stan-dardization (Table 10-1). Since then, Specification No.28 has been modified again (1996), and still anotherrevision is in progress.

The ANSI/ADA standards have also been set forother instruments and filling materials: No. 58,Hedstroem files; No. 63, rasps and barbed broaches;No. 71, spreaders and condensers; No. 95, root canalenlargers; as well as No. 57, filling materials; No. 73,absorbent points; and No.78, obturating points. TheISO’s standards are comparable with these specifica-tions (N Luebke, personal communication, March24, 1999).

Initially, manufacturers of endodontic instrumentsworldwide adhered rather closely to these specifica-tions. Some variations have been noted, however, in sizemaintenance (both diameter and taper), surface debris,cutting flute character, torsional properties, stiffness,cross-sectional shape, cutting tip design, and type ofmetal59–65 (Figure 10-13). More recently, Stenman andSpangberg were disappointed to note that the dimen-sions of root canal instruments are becoming poorlystandardized and that few brands are now withinacceptable dimensional standards.66

Cormier et al. and Seto have both warned of theimportance of using only one brand of instrumentsbecause of discrepancies in instrument size amongmanufacturers.61,62 Early on, Seto also noted that grind-ing the flutes in files rather than twisting them “does notimprove the strength or ductility of the instru-ment…(and) may also create more undesirable flutingdefects.”63 Since then, however, grinding has improvedand gained importance since all nickel-titanium instru-ments must be machined, not twisted. Several recentstudies have indicated that this type of manufacturingdoes not weaken instruments. In fact, most studies indi-cate that both manufacturing processes produce filesthat meet or exceed ADA standards.67–69

It has also been found that autoclaving has no sig-nificant deleterious effects on stainless steel or nickel-titanium endodontic instruments.70–72

ISO Grouping of Instruments

In due time, the ISO-Fédération Dentaire Internationalcommittee grouped root canal instruments accordingto their method of use:

Figure 10-12 Standardized dimensions of root canal files andreamers established by the ISO. Two modifications from Ingle’soriginal proposal are an additional measurement at D3, 3 mm fromD1, and specification for shapes of the tip: 75 degrees, ± 15 degrees.The taper of the spiral section must be at a 0.02 mm gain for eachmillimeter of cutting length. Specifications for a noncutting tip areforthcoming.

Page 71: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 475

• Group I: Hand use only—files, both K type (Kerr)and H type (Hedstroem); reamers, K type and Utype; and broaches, pluggers, and spreaders.

• Group II: Engine-driven latch type—same design asGroup I but made to be attached to a handpiece. Alsoincluded are paste fillers.

• Group III: Engine-driven latch type—drills orreamers such as Gates-Glidden (G type). Peeso (Ptype), and a host of others—A-, D-, O-, KO-, T-,M-type reamers and the Kurer Root-Facer.

• Group IV: Root canal points—gutta-percha, silver,paper.

The ISO grouping of endodontic instruments makesconvenient a discussion by group of their manufacture,use, cutting ability, strengths, and weaknesses.

ISO Group I Instruments, Reamers, or Files. Firstdesigned as early as 1904 by the Kerr ManufacturingCompany (Figure 10-14), K-style files and reamers arethe most widely copied and extensively manufactured

endodontic instruments worldwide. Now made univer-sally of nickel titanium and stainless steel rather thancarbon steel, K-type instruments are produced using oneof two techniques. The more traditional is produced bygrinding graduated sizes of round “piano” wire into var-ious shapes such as square, triangular, or rhomboid. Asecond grinding operation properly tapers these pieces.To give the instruments the spirals that provide the cut-ting edges, the square or triangular stock is then graspedby a machine that twists it counterclockwise a pro-grammed number of times—tight spirals for files, loosespirals for reamers. The cutting blades that are producedare the sharp edges of either the square or the triangle. Inany instrument, these edges are known as the “rake” ofthe blade. The more acute the angle of the rake, thesharper the blade. There are approximately twice thenumber of spirals on a file than on a reamer of a corre-sponding size (Figure 10-15, A, B).

The second and newer manufacturing method is togrind the spirals into the tapered wire rather than twistthe wire to produce the cutting blades. Grinding istotally necessary for nickel-titanium instruments.Because of their superelasticity, they cannot be twisted.

Originally, the cross-section of the K file was squareand the reamer triangular. Recently, manufacturershave started using many configurations to achieve bet-ter cutting and/or flexibility. Cross-section is now theprerogative of individual companies.

K-Style Modification. After having dominated themarket for 65 years, K-style endodontic instrumentscame into a series of modifications beginning in the1980s. Not wholly satisfied with the characteristics oftheir time-honored K-style instrument, the KerrManufacturing Company in 1982 introduced a newinstrument design that they termed the K-Flex File(Sybron Endo/Kerr; Orange Calif.), a departure from thesquare and triangular configurations (Figure 10-15, C).

The cross-section of the K-Flex is rhombus or dia-mond shaped. The spirals or flutes are produced by thesame twisting procedure used to produce the cuttingedge of the standard K-type files; however, this newcross-section presents significant changes in instru-ment flexibility and cutting characteristics. The cuttingedges of the high flutes are formed by the two acuteangles of the rhombus and present increased sharpnessand cutting efficiency. The alternating low flutesformed by the obtuse angles of the rhombus are meantto act as an auger, providing more area for increaseddebris removal. The decreased contact by the instru-ment with the canal walls provides a space reservoirthat, with proper irrigation, further reduces the dangerof compacting dentinal filings in the canal.

Table 10-1 Dimensions in Millimeters. Revision ofADA Specification No. 28 Added Instrument Sizes 08and 110 to 150 to the Original Specification

Diameter (Tolerance ± 0.02 mm)Handle

Size D1 mm D2 mm D3 mm Color Code

08 0.08 0.40 0.14 Gray10 0.10 0.42 0.16 Purple15 0.15 0.47 0.21 White20 0.20 0.52 0.26 Yellow25 0.25 0.57 0.31 Red30 0.30 0.62 0.36 Blue35 0.35 0.67 0.41 Green 40 0.40 0.72 0.46 Black45 0.45 0.77 0.51 White50 0.50 0.82 0.56 Yellow55 0.55 0.87 0.61 Red60 0.60 0.92 0.66 Blue70 0.70 1.02 0.76 Green80 0.80 1.12 0.86 Black90 0.90 1.22 0.96 White

100 1.00 1.32 1.06 Yellow110 1.10 1.42 1.16 Red120 1.20 1.52 1.26 Blue130 1.30 1.62 1.36 Green140 1.40 1.72 1.46 Black150 1.50 1.82 1.56 White

*New diameter measurement point (D3) was added 3 mm fromthe tip of the cutting end of the instrument. Handle color cod-ing is official.

Page 72: Ch10: ENDODONTIC CAVITY PREPARATION

476 Endodontics

Figure 10-13 Comparisons of the condition of unused instruments from different manufacturers. A, New No. 30 K file with consistentlysharp blades and point. B, New No. 35 K file, different brand, exhibiting dull blades. C, Cross-sectional profile of triangular No. 20 file show-ing consistency in angles. D, Cross-section of competing No. 20 file with dull, rounded angles of cutting blades. E, No. 15 file showing lackof consistency in the blade, reflecting poor quality control. F, New No. 08 file with no cutting blades at all.

A B

C D

FE

Page 73: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 477

Testing five brands of K-type files for stiffness, theSan Antonio group found K-Flex files to be the mostflexible. Moreover, not a single K-Flex fractured intorque testing, even when twisted twice the recom-mended level in the ADA specification.73

More recently, Kerr has introduced a hybrid instru-ment they call the Triple-Flex File (Kerr; Orange,Calif.) It has more spiral flutes than a K reamer butfewer than a K file. Made from triangular stainless steeland twisted, not ground, the company claims theinstrument is more aggressive and flexible than the reg-ular K-style instruments (see Figure 10-15, D).

Reamers. The clinician should understand theimportance of differentiating endodontic files andreamers from drills. Drills are used for boring holes insolid materials such as gold, enamel, and dentin. Files,by definition, are used by rasping.

Reamers, on the other hand, are instruments thatream—specifically, a sharp-edged tool for enlarging ortapering holes (see Figure 10-15B). Traditionalendodontic reamers cut by being tightly inserted intothe canal, twisted clockwise one quarter- to one half-turn to engage their blades into the dentin, and thenwithdrawn—penetration, rotation, and retraction.6

The cut is made during retraction. The process is thenrepeated, penetrating deeper and deeper into the canal.When working length is reached, the next size instru-ment is used, and so on.

Reaming is the only method that produces a round,tapered preparation, and this only in perfectly straightcanals. In such a situation, reamers can be rotated onehalf-turn before retracting. In a slightly curved canal, areamer should be rotated only one quarter-turn. Morestress may cause breakage. The heavier reamers, however,size 50 and above, can almost be turned with impunity.

Files. The tighter spiral of a file (see Figure 10-15, A)establishes a cutting angle (rake) that achieves its primaryaction on withdrawal, although it will cut in the push

motion as well. The cutting action of the file can beeffected in either a filing (rasping) or reaming (drilling)motion. In a filing motion, the instrument is placedinto the canal at the desired length, pressure is exertedagainst the canal wall, and while this pressure is main-tained, the rake of the flutes rasps the wall as the instru-ment is withdrawn without turning. The file need notcontact all walls simultaneously. For example, theentire length and circumference of large-diametercanals can be filed by inserting the instrument to thedesired working distance and filing circumferentiallyaround all of the walls.

To use a file in a reaming action, the motion is thesame as for a reamer—penetration, rotation, andretraction.6 The file tends to set in the dentin morereadily than the reamer and must therefore be treatedmore gingerly. Withdrawing the file cuts away theengaged dentin.

Figure 10-15 ISO Group I, K-style endodontic instruments. A.K-style file. B. K-style reamer. C. K-flex file. D. Triple-Flex file withtip modification.

Figure 10-14 Historical illustration, circa 1904, of the originalKerr reamer (titled a broach at that time), the origin of today’s K-style instruments. (Courtesy of Kerr Dental Manufacturing Co.,1904 catalog.)

A C DB

Page 74: Ch10: ENDODONTIC CAVITY PREPARATION

The tactile sensation of an endodontic instrument“set” into the walls in the canal may be gained bypinching one index finger between the thumb and fore-finger of the opposite hand and then rotating theextended finger (Figure 10-16).

To summarize the basic action of files and reamers,it may be stated that either files or reamers may be usedto ream out a round, tapered apical cavity but that filesare also used as push-pull instruments to enlarge byrasping certain curved canals as well as the ovoid por-tion of large canals. In addition, copious irrigation andconstant cleansing of the instrument are necessary toclear the flutes and prevent packing debris at orthrough the apical foramen (Figure 10-17).

The subject addressed—how K-style files and ream-ers work—must logically be followed by asking howwell they work. One is speaking here, primarily, aboutstainless steel instruments.

Oliet and Sorin evaluated endodontic reamers fromfour different manufacturers and found “considerablevariation in the quality, sharpness of the cutting edges,cross sectional configuration, and number of flutes ofthe 147 different reamers tested.” They further foundthat “triangular cross sectional reamers cut with greaterefficiency than do the square cross sectional reamers,”but the failure rate of the triangular instruments was

478 Endodontics

considerably higher.74 Webber et al. found that “instru-ments with triangular cross sections were initially moreefficient but lost sharpness more rapidly than squareones of the same size.”75

Oliet and Sorin also found that “wear does notappear to be a factor in instrument function, but ratherinstruments generally fail because of deformation orfracture of the blades. Once an instrument became per-manently distorted, additional rotation only causedadditional distortion, with minimum cutting frequent-ly leading to fracture.”74 A more recent in vitro study ofstainless steel files at Connecticut demonstrated thatsignificant wear and potential loss of efficiency occurredafter only one use of 300 strokes. They proposed thatendodontic instruments should be available in sterilepackaging for single-patient use.76 Another study, fromBrazil, concluded that stainless steel instruments, insmall sizes, should be used once, and the No. 30 couldbe used three times. The No. 30 nickel-titanium instru-ments, however, “even after five times, did not showappreciable abnormalities in shape.”77 Most endodon-tists use the small instruments, 08 to 25 sizes only once.

Webber et al. used a linear cutting motion in moistbovine bone and found that “there was a wide range ofcutting efficiency between each type of root canalinstrument, both initially and after successive use.”75

Figure 10-16 Demonstration of sensation of an endodonticinstrument, which is “set” into dentin walls during reaming action.

Figure 10-17 “Worm” of necrotic debris forced from the apexduring canal enlargement. This mass of material could contain mil-lions of bacteria that act as a nidus for acute apical abscess.

Page 75: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 479

Similar findings were made by a group at MarquetteUniversity, who compared K-type files with five recent-ly introduced brands in three different sizes, Nos. 20, 25,and 30.78 Significant differences were noted in the invitro cutting efficiency among the seven brands. Wearwas exhibited by all instruments after three successive 3-minute test periods. Depth of groove is also a significantfactor in improving cutting ability (Figure 10-18).

A group of researchers in Michigan also studied thecutting ability of K-type files.79 They reported a widevariance in the cutting ability of individual files. Thisstudy appears to confirm what dentists have longnoted—the wide variance in cutting ability amongindividual instruments, even from the same manufac-turer. Contrary to the Marquette findings,78 this studyreported an insignificant role played by wear indecreasing the cutting ability of regular K-type stainlesssteel files.79 This speaks of the strength of instruments,but what of their weaknesses?

The Oliet and Sorin,74 Webber et al.75 and Neal etal.79 studies all alluded to certain weaknesses in K-style

instruments. In addition, Luks has shown that thesmaller reamers and files may be easily broken by twist-ing the blades beyond the limits of the metal until themetal separated.80 On the other hand, Gutierrez et al.found that although the instrument did not immedi-ately break, a progression of undesirable featuresoccurred.81 Locking and twisting clockwise led tounwinding and elongation as well as the loss of bladecutting edge and blunting of the tip. With continuedclockwise twisting, a reverse “roll-up” occurred. Cracksin the metal eventually developed that finally resultedin breakage, with all of its attendant problems. Thesefindings were unusual in that breakage would have nor-mally resulted long before “roll-up” occurred. It mayreflect a variance in the quality of metal used by theindividual manufacturing companies. This point wasborne out in a study by Lentine, in which he found awide range of values within each brand of instrumentas well as between brands.82

An additional study of 360-degree clockwise rota-tion (ISO revision of ADA Specification No. 28) found

Figure 10-18 Comparison between two competing brands of endodontic instruments showing widely different cutting ability related to thedepth of the blade groove.

Page 76: Ch10: ENDODONTIC CAVITY PREPARATION

only 5 K-style files failing of 100 instruments tested.They were sizes 30 to 50, all from one manufacturer.73

Attempts to “unscrew” a locked endodontic file alsopresent a problem. Researchers at NorthwesternUniversity demonstrated that “endodontic files twistedin a counterclockwise manner were extremely brittle incomparison to those twisted in a clockwise manner.”83

They warned that dentists “should exercise cautionwhen ‘backing-off ’ embedded root canal instruments.”This finding was strongly supported by Lautenschlagerand colleagues, who found that “all commercial filesand reamers showed adequate clockwise torque, butwere prone to brittle fracture when placed in counter-clockwise torsion.”84

In contrast, Roane and Sabala at the University ofOklahoma found that clockwise rotation was morelikely (91.5%) to produce separation and/or distortionthan counterclockwise rotation (8.5%) when theyexamined 493 discarded instruments.85 In laboratorytests, the Washington group also found greater rota-tional failure in clockwise rotation and greater failurein machined stainless steel K files over twisted K files.63

Sotokawa in Japan also studied discarded instru-ments and indicted metal fatigue as the culprit in break-age and distortion86: “First a starting point crack devel-ops on the file’s edge and then metal fatigue fans outfrom that point, spreading towards the file’s axial cen-ter” (Figure 10-19). Sotokawa also classified the types ofdamage to instruments (Figure 10-20). He found theNo. 10 file to be the most frequently discarded.86

Montgomery evaluated file damage and breakagefrom a sophomore endodontics laboratory and also

480 Endodontics

found that most damage (87%) “occurred while filingcanals in posterior teeth with #10 stainless files. One fileseparated for every 3.91 posterior teeth that were filed,”and each student averaged over 5 (range 1 to 11) dam-aged files in the exercise.87

A group in France compared instrument fracturebetween traditional K and H files and the newer“hybrid” instruments. They found that “the instru-ments with triangular cross sections, in particular theFlexofile (Dentsply/Maillefer; Tulsa, Okla.), were foundto be the most resistant to fracture.” French researchers,like the Japanese researchers, found starting-pointcracks and ductile fracture as well as plastic deforma-tions and axial fractures88 (Figure 10-21).

A group at the University of Washington comparedrotation and torque to failure of stainless steel andnickel-titanium files of various sizes. An interestingrelation was noted. Stainless steel had greater rotationsto failure in a clockwise direction, and the nickel titani-um was superior in a counterclockwise direction.Despite these differences, the actual force to cause fail-ure was the same.89

Buchanan, among others, pointed out the importanceof bending stainless steel files to conform to curvedcanals. He recommended the use of pliers to make theproper bend.90 Yesilsoy et al. on the other hand, observeddamage (flattening of the flutes) in cotton plier-bent files(Figure 10-22, A). The finger-bent files, however,although not damaged, were coated with accumulateddebris-stratified squamous epithelium cells and nail ker-atin91 (Figure 10-22, B). Finger-bent files should be bentwhile wearing washed rubber gloves or between a sterile

Figure 10-19 Instrument breakage. A, Initial crack across the shaft near the edge of the blade, Type V (original magnification ×1,000). B,Full fracture of file broken in a 30-degree twisting simulation, Type VI ( original magnification ×230). Reproduced with permission fromSotokawa T.86

A B

Page 77: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 481

Figure 10-20 A, Sotokawa’s classification ofinstrument damage. Type I, Bent instrument.Type II, Stretching or straightening of twist con-tour. Type III, Peeling-off metal at blade edges.Type IV, Partial clockwise twist. Type V,Cracking along axis. Type VI, Full fracture.B, Discarded rotary nickel-titanium files show-ing visible defects without fracture. All filesshow unwinding, indicating a torsional defect,and are very dangerous to be used further.A reproduced with permission from SotokawaT.86 B reproduced with permission fromSattapan B, Nervo GJ, Palamara JEA, MesserHH. JOE 2000;26:161.

A

B

Figure 10-21 Instrument fracture by cracks and deformation. A, Broken Hedstroem file with starting point at i (far right) spreading tocracks (S) and ductile fracture (F). B, Broken K-Flex file with plastic deformations at D and axial fissure at Fs. Reproduced with permissionfrom Haikel Y et al.88

A B

Page 78: Ch10: ENDODONTIC CAVITY PREPARATION

gauze sponge. Maillefer manufactures a hand tool calleda Flexobend (Dentsply/Maillefer; Tulsa, Okla.) for prop-erly bending files without damage.

To overcome the problems chronicled above—distor-tion, fracture, and precurvature—a group at MarquetteUniversity suggested that nickel titanium, with a verylow modulus of elasticity, be substituted for stainlesssteel in the manufacture of endodontic instruments.92

On the other hand, the cutting efficiency of the Nitinol#35 K files was only 60% that of matching stainless steel files.93

Tip Modification. Early interest in the cuttingability of endodontic instruments centered around thesharpness, pitch, and rake of the blades. By 1980, inter-est had also developed in the sharpness of the instru-ment tip and the tip’s effect in penetration and cuttingas well as its possible deleterious potential for ledgingand/or transportation—machining the preparationaway from the natural canal anatomy.

The Northwestern University group noted that tipdesign, as much as flute sharpness, led to improved cut-ting efficiency.94 They later designed experiments toexclude tip design because the tip might “overshadowthe cutting effects of flute design.”95 Somewhat later,they reported that “tips displayed better cutting efficien-

482 Endodontics

cy than flutes” and that triangular pyramidal tips out-performed conical tips, which were least effective.96,97

At the same time that a pitch was being made for theimportance of cutting tips, other researchers, centeredaround the University of Oklahoma, were redesigningtips that virtually eliminated their cutting ability. Powellet al. began modifying the tips of K files by “grinding toremove the transition angle” from tip to first blade.98,99

This was an outgrowth of Powell’s indoctrination at theUniversity of Oklahoma by Roane et al.’s introductionof the Balanced Force concept of canal preparation.100

By 1988, Sabala et al. confirmed previous findingsthat the modified tip instruments exerted “less trans-portation and more inner curvature preparation. Themodified files maintained the original canal curvaturebetter and more frequently than did the unmodifiedfiles.”101 These findings were essentially confirmed invitro by Sepic et al.102 and in vivo by McKendry et al.103

Powell et al. noted that each stainless steel “file’smetallic memory to return to a straight position,increases the tendency to transport or ledge and eventu-ally to perforate curved canals.”99 This action takes placeon the outer wall, the convex curvature of the canal.They pointed out that when this tip “angle is reduced,the file stays centered within the original canal and cuts

Figure 10-22 Instruments precurved with cotton pliers or fingers. A, Cotton plier-precurved No. 25 file with attached metal chips, left.Flutes are badly damaged. B, Finger-precurved No. 25 file with accumulated cellular debris between flutes. Reproduced with permission fromYesilsoy C et al.91

BA

Page 79: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 483

all sides (circumference) more evenly.” This modified-tipfile has been marketed as the Flex-R-file (Moyco/UnionBroach, Miller Dental; Bethpage, N.Y.) (Figure 10-23).

Recognizing the popularity of modified-tip instru-ments, other companies have introduced such instru-ments as Control Safe files (Dentsply/Maillefer; Tulsa,Okla.), the Anti-Ledging Tip file (Brasseler; Savannah,Ga.), and Safety Hedstrom file (Sybron Endo/Kerr;Orange, Calif.).

At the University of Wales, rounded-tipped fileswere compared with other files with triangular cross-sections and various forms of tip modification.Although the round-tipped files were the least efficient,they prepared canals more safely and with less destruc-tion than did the other files.104

Hedstroem Files (aka Hedstrom). H-type files aremade by cutting the spiraling flutes into the shaft of apiece of round, tapered, stainless steel wire. Actually, themachine used is similar to a screw-cutting machine. Thisaccounts for the resemblance between the Hedstroemconfiguration and a wood screw (Figure 10-24, A).

It is impossible to ream or drill with this instrument.To do so locks the flutes into the dentin much as ascrew is locked in wood. To continue the drilling actionwould fracture the instrument. Furthermore, the file isimpossible to withdraw once it is locked in the dentinand can be withdrawn only by backing off until theflutes are free. This action also “separates” files.

Hedstroem files cut in one direction only—retrac-tion. Because of the very positive rake of the flute

design, they are also more efficient as files per se.105–110

French clinicians (Yguel-Henry et al.) reported on theimportance of the lubricating effect of liquids on cut-ting efficiency, raising this efficiency by 30% with H-style files and 200% with K-files.108 Temple Universityresearchers, however, reported the proclivity that Hfiles have for packing debris at the apex.106 On theother hand, El Deeb and Boraas found that H filestended not to pack debris at the apex and were themost efficient.110

Owing to their inherent fragility, Hedstroem files arenot to be used in a torquing action. For this reason,ADA Specification No. 28 could not apply, and a newspecification, No. 58, has been approved by the ADAand the American National Standards Committee.111

H-Style File Modification. McSpadden was thefirst to modify the traditional Hedstroem file. Marketedas the Unifile and Dynatrak, these files were designedwith two spirals for cutting blades, a double-helixdesign, if you will. In cross-section, the blades present-ed an “S” shape rather than the single-helix teardropcross-sectional shape of the true Hedstroem file.

Unfortunately, breakage studies revealed that theUnifile generally failed the torque twisting test (as did thefour other H files tested) based on ISO Specification No.58.112 The authors concluded that the specification wasunfair to H-style files, that they should not be twistedmore than one quarter-turn.73,112 At this time, Unifilesand Dynatraks are no longer being marketed; however,the Hyflex file (Coltene/Whaledent/Hygenic, Mahwah,

Figure 10-23 Flex-R-file with noncutting tip. A, Note rounded tip. B, “Nose” view of a noncutting tip ensures less gouging of the externalwall and reduced cavity transport. (Courtesy of Moyco Union Broach Co.)

Page 80: Ch10: ENDODONTIC CAVITY PREPARATION

484 Endodontics

N.J.) appears to have the same cross-sectional configura-tion. The “S” File (J-S Dental; Ridgefield, Conn.) alsoappears to be a variation of the Unifile in its double-helixconfiguration. Reports on this instrument are very favor-able.109,113 Buchanan has further modified theHedstroem file, the Safety Hedstrom (Sybron Endo/Kerr;Orange, Calif.), which has a noncutting side to preventledging in curved canals (see Figure 10-24, B right).

The U-File. A new endodontic classification ofinstrument, for which there is no ISO or ANSI/ADAspecification as yet, is the U-File, developed by Heath(personal communication, May 3, 1988) and marketedas ProFiles, GT Files (Dentsply/Tulsa Dental; Tulsa,Okla.), LIGHTSPEED (LightSpeed Technology Inc; SanAntonio, Tex.), and Ultra-Flex files (Texeed Corp., USA).

The U-File’s cross-sectional configuration has two90-degree cutting edges at each of the three points ofthe blade (Figure 10-25, A). The flat cutting surfaces actas a planing instrument and are referred to as radiallands. Heath pointed out that the new U shape adaptswell to the curved canal, aggressively planing the exter-nal convex wall while avoiding the more dangerousinternal concave wall, where perforation strippingoccurs (Figure 10-25, B). A noncutting pilot tip ensuresthat the file remains in the lumen of the canal, thusavoiding transportation and “zipping” at the apex. The

Figure 10-24 ISO Group I, H-style instruments. A. MailleferHedstroem file resembling a wood screw. B. Modified Hedstroemfile (left) with non-cutting tip.“Safety” Hedstroem (right) with flat-tened non-cutting side to prevent “stripping”. A. Reproduced withpermission from Keate KC and Wong M.64

Figure 10-25 A, Cross-sectional view of a U File reveals six corners in cutting blades compared with four corners in square stock and threecorners in triangular stock K files. B, Nickel-titanium U-shaped files in C-shaped molar canals. Note extreme flexibility (arrow) without sep-aration. (A courtesy of Derek Heath, Quality Dental Products. B courtesy of Dr. John McSpadden.)

A B

Page 81: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 485

files are used in both a push-pull and rotary motion andare very adaptable to nickel-titanium rotary instru-ments. ProFiles are supplied in 0.04, 0.05, 0.06, 0.07,and 0.08 tapers and ISO tip sizes of 15 through 80.

GT ProFiles, developed by Buchanan in the U design,are unusual in that the cutting blades extend up the shaftonly 6 to 8 mm rather than 16 mm, and the tapers startat 0.06 mm/mm (instead of 0.02), as well as 0.08 and0.10, tapered instruments. They are made of nickel tita-nium and come as hand instruments and rotary files. GTinstruments all start with a noncutting tip ISO size 20.

An unusual variation of the U-shaped design is theLIGHTSPEED instrument114–117 (Figure 10-26). Madeonly in nickel titanium, it resembles a Gates-Gliddendrill in that it has only a small cutting head mountedon a long, noncutting shaft. It is strictly a rotary instru-ment but comes with a handle that may be added to thelatch-type instrument for hand use in cleaning andshaping abrupt apical curvatures where rotary instru-ments may be in jeopardy. The instruments come inISO sizes beginning with No. 20 up to No. 100. Halfsizes begin at ISO 22.5 and range to size 65. The headsare very short—only 0.25 mm for the size 20 and up to1.75 mm for the size 100.

It is recommended that the LIGHTSPEED be used at1,300 to 2,000 rpm and that the selected rpm remainconstant. As with many of the new rotary instruments,this speed calls for a controlled, preferably electrichandpiece. One of LIGHTSPEED’s touted advantagesis the ability to finish the apical-third preparation to alarger size if dictated by the canal diameter. It has beensaid that “canal diameter, particularly in the apicalthird, is a forgotten dimension in endodontics” (per-sonal communication, Dr. Carl Hawrish, 1999).

Gates-Glidden Modification. A hand instrumentalso designed for apical preparation is the Flexogates,aka Handygates (Dentsply/Maillefer; Tulsa, Olka.). Asafe-tipped variation of the traditional Gates-Gliddendrill, the Flexogates is still to be tested clinically,

although Briseno et al. compared Flexogates and CanalMaster (Brasseler, Savannah, Ga.) in vitro and foundFlexogates less likely to cause apical transportation(Figure 10-27).118

Quantec “Files.” The newly designed Quantecinstrument (Sybron-Endo/Kerr; Orange, Calif.), althoughcalled a “file,” is more like a reamer—a drill, if you will.It is not designed to be used in the file’s push-pull actionbut rather in the reamer’s rotary motion. Produced asboth hand- and rotary-powered instruments, theQuantec has proved to be very effective as a poweredinstrument. First designed by McSpadden, the instru-ment has undergone a number of modifications thathave improved its efficiency and safety. Quantec is pro-duced in three different tapers—0.02, 0.04, and 0.06mm/mm—as well as safe-cutting and noncutting tips(Figure 10-28). The instruments are sized at the tip andnumbered according to the ISO system—15, 20, 25, etc.The radial lands of the Quantec are slightly relieved toreduce frictional contact with the canal wall, and thehelix angle is configured to efficiently remove debris.

Hand Instrument Conclusions. The literature isreplete with references to the superiority of one instru-ment or one method of preparation over all oth-ers.110,119–122 Quite true is the statement, “Regardless ofthe instrument type, none was able to reproduce ideal

Figure 10-26 The unusual LightSpeed instrument. “U” shaped indesign with a noncutting tip, the LightSpeed cutting head termi-nates a 16 mm noncutting shaft. Made only in nickel titanium in ISOsizes 20 to 100 and in half sizes as well, they are used in rotary prepa-rations at 2,000 rpm. (Courtesy of LightSpeed Technology Inc.)

Figure 10-27 Flexogates (aka “Handy Gates”) hand-powered ver-sion of a Gates-Glidden drill used to perfect apical cavity prepara-tion. Note the safe noncutting pilot tip. (Courtesy ofDentsply/Maillefer.)

Page 82: Ch10: ENDODONTIC CAVITY PREPARATION

results; however, clinically acceptable results could beobtained with all of them.”123 These German authorswent on to say,“These observations were subjective andmight differ from one operator to another.”

All too often clinicians report success with the instru-ments and technique with which they are most comfort-able. No ulterior motive is involved, but often a reportreflects badly on an instrument when it is the clinician’sinexperience with an unfamiliar technique that isunknowingly being reported. Stenman and Spångbergsaid it best: it “is difficult to assess, as results from pub-lished investigations often vary considerably.”124

Barbed Broaches. Barbed broaches are short-han-dled instruments used primarily for vital pulp extirpation.They are also used to loosen debris in necrotic canals or toremove paper points or cotton pellets. ISO SpecificationNo. 63 sets the standards for barbed broaches. Rueggebergand Powers tested all sizes of broaches from three manu-facturers and found significant differences in shape,design, and size, as well as results from torsion and deflec-tion tests.125 The authors warned that a “jammed broach”should be removed vertically without twisting.

Broaches are manufactured from round wire, thesmooth surface of which has been notched to formbarbs bent at an angle from the long axis (Figure 10-29,A). These barbs are used to engage the pulp as thebroach is carefully rotated within the canal until itbegins to meet resistance against the walls of the canal.The broach should never be forced into a canal beyondthe length where it first begins to bind. Forcing it fartherapically causes the barbs to be compressed by the canal

486 Endodontics

walls. Subsequent efforts to withdraw the instrumentwill embed the barbs in the walls. Increased withdrawalpressure to retrieve the instrument results in breakingoff the embedded barbs or the shaft of the instrumentitself at the point of engagement (Figure 10-29, B). Abroken barbed broach embedded in the canal wall is sel-dom retrievable. (Proper use of this instrument will bedescribed in the section on pulpectomy.)

There is also a smooth broach, sometimes used as apathfinder. The newly released Pathfinder CS (Sybron-Endo/Kerr; Orange, Calif.), made of carbon steel, is lesslikely to collapse when forced down a fine canal.Carbon steel will rust and cannot be left in sodiumhypochlorite.

NICKEL-TITANIUM ENDODONTIC INSTRUMENTS

A new generation of endodontic instruments, madefrom a remarkable alloy, nickel titanium, has added astriking new dimension to the practice of endodontics.The superelasticity of nickel titanium, the property thatallows it to return to its original shape following signif-icant deformation, differentiates it from other metals,such as stainless steel, that sustain deformation andretain permanent shape change. These properties makenickel-titanium endodontic files more flexible and bet-ter able to conform to canal curvature, resist fracture,and wear less than stainless steel files.

History. In the early 1960s, the superelastic proper-ty of nickel-titanium alloy, also known as Nitinol, wasdiscovered by Buehler and Wang at the US NavalOrdnance Laboratory.126 The name Nitinol was derivedfrom the elements that make up the alloy, nickel andtitanium, and “nol” for the Naval Ordnance Laboratory.The trademark Nitinol refers specifically to the firstnickel-titanium wire marketed for orthodontics.

As early as 1975, Civjan and associates127 reportedon potential applications of nickel-titanium alloys con-taining nickel 55% by weight (55-Nitinol) and nickel60% by weight (60-Nitinol). They found that the char-acteristics of 60-Nitinol suggested its use in the fabrica-tion of tough corrosion-resistant hand or rotary cut-ting instruments or files for operative dentistry, sur-gery, periodontics, and endodontics. Further, it wassuggested that 55- or 60-Nitinol could be used for themanufacture of corrosion-resistant root canal points toreplace silver points.

A first potential use of nickel titanium in endodon-tics was reported in 1988 by Walia and associates.128

Number 15 files fabricated from nickel-titanium ortho-dontic alloy were shown to have two or three times theelastic flexibility in bending and torsion, as well as supe-

Figure 10-28 Quantec “files” are more like a reamer, a drill as itappears, and are used in a rotary motion, not push-pull A, Quantecsafe-cutting tip file. B, Quantec noncutting tip file. The files areproduced in three different tapers: 0.02, 0.04, and 0.06 mm/mm.(Courtesy of Sybron-Endo/Kerr)

A

B

Page 83: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 487

rior resistance to torsional fractures, compared with No.15 stainless steel files manufactured by the sameprocess. The results suggested that Nitinol files might bepromising for the instrumentation of curved canals.

In 1992, a collaborative group made a decision toexamine and study the possibility of producing nickel-titanium instruments. The nickel-titanium revolutionin endodontics followed, and in May 1992, Sereneintroduced these new files to students in the College ofDental Medicine at the Medical University of SouthCarolina. Later these and other similar files becameavailable to the profession generally.

Superelasticity

Alloys such as nickel titanium, that show superelastici-ty, undergo a stress-induced martensitic transforma-tion from a parent structure, which is austenite. Onrelease of the stress, the structure reverts back toaustenite, recovering its original shape in the process.Deformations involving as much as a 10% strain can becompletely recovered in these materials, as comparedwith a maximum of 1% in conventional alloys.

In a study comparing piano wire and a nickel-titani-um wire, Stoeckel and Yu found that a stress of 2500MPa was required to stretch a piano wire to 3% strain,

Figure 10-29 A, Barbed broach. As a result of a careless barbing process, the effective shaft diameter is greatly reduced. Size “coarse.” B,Ductile failure of size “xx fine” barbed broach fractured after axial twisting greater than 130 degrees. C, Brittle failure of coarse broach causedby twisting while jammed in place. Reproduced with permission from Rueggeberg FA and Powers JM.125

Page 84: Ch10: ENDODONTIC CAVITY PREPARATION

as compared with only 500 MPa for a nickel-titaniumwire.129 At 3% strain, the music wire breaks. On theother hand, the nickel-titanium wire can be stretchedmuch beyond 3% and can recover most of this defor-mation on the release of stress.

The superelastic behavior of nickel titanium alsooccurs over a limited temperature window. Minimumresidual deformation occurs at approximately roomtemperature.129 A composition consisting of 50 atomicpercent nickel and 50 atomic percent titanium seemsideal, both for instrumentation and manufacture.

Manufacture. Today, nickel-titanium instrumentsare precision ground into different designs (K style,Hedstrom, Flex-R, X-double fluted, S-double fluted, Ufiles, and drills) and are made in different sizes andtapers. In addition, spreaders and pluggers are alsoavailable. Nickel-titanium instruments are as effectiveor better than comparable stainless steel instruments inmachining dentin, and nickel-titanium instruments aremore wear resistant.130 U and drill designs make it pos-sible to use mechanical (ie, rotary handpiece) instru-mentation. Moreover, new prototype rotary motorsnow offer the potential for improved torque controlwith automatic reversal that may ultimately decreaserotary instrument breakage.

Finally, nickel-titanium files are biocompatible andappear to have excellent anticorrosive properties.131 Inaddition, implantation studies have verified that nickeltitanium is biocompatible and acceptable as a surgicalimplant.132 In a 1997 AAE questionnaire, the endodon-tic membership answered the following question, “Doyou think nickel-titanium instruments are here to stayand will become basic armamentaria for endodontictreatment?” The responses were quite positive: “yes,”72%; “maybe,” 21%; and “no,” 4%.133

With the ability to machine flutes, many new designssuch as radial lands have become available. Radial landsallow nickel-titanium files to be used as reamers in a 360-degree motion as opposed to the traditional reamers withmore acute rake angles. Although the most common useof this new design has been as a rotary file, the identicalinstrument is available as a hand instrument. In addition,a converter handle is available that allows the operator touse the rotary file as a hand instrument.

Torsional Strength and Separation. The clinicianswitching from stainless to nickel-titanium hand instru-ments should not confuse nickel titanium’s superelasticcharacteristics with its torsional strength and so assumethat it has super strength. This misconception has led tounnecessary file breakage when first using this newmetal. Studies indicate that instruments, whether stain-less steel or nickel titanium, meet or exceed ANSI/ADA

488 Endodontics

Specification No. 28. However, when reviewing the lit-erature on this subject the results seem to be mixed.Canalda and Berastequi found nickel-titanium files(Nitiflex and Naviflex) (Dentsply; Tulsa, Okla.) to bemore flexible than the stainless files tested (Flexofile andFlex-R).134 However, the stainless steel files were foundto be more resistant to fracture. Both types of metalexceeded all ANSI/ADA specifications. Canalda et al., inanother study, compared identical instruments:CanalMaster (aka LIGHTSPEED) stainless steel andCanalMaster nickel titanium. Within these designs, thenickel-titanium values were superior in all aspects tothose of stainless steel of the same design.135

Tepel et al. looked at bending and torsional proper-ties of 24 different types of nickel-titanium, titanium-aluminum, and stainless steel instruments.136 Theyfound the nickel-titanium K files to be the most flexi-ble, followed in descending order by titanium alu-minum, flexible stainless steel, and conventional stain-less steel. When testing for resistance to fracture for 21brands, however, they found that No. 25 stainless steelfiles had a higher resistance to fracture than their nick-el-titanium counterpart.136

Wolcott and Himel, at the University of Tennessee,compared the torsional properties of stainless steel K-type and nickel-titanium U-type instruments. As inprevious studies, all of the stainless steel instrumentsshowed no significant difference between maximumtorque and torque at failure, whereas the nickel-titani-um instruments showed a significant differencebetween maximum torque and torque at failure.137

Essentially, this means that the time between “wind-up” and fracture in nickel-titanium instruments isextended, which could lead to a false sense of security.

While studying cyclic fatigue using nickel-titaniumLIGHTSPEED instruments, Pruett et al. determinedthat canal curvature and the number of rotationsdetermined file breakage. Separation occurred at thepoint of maximum curvature of the shaft.138 Cyclicfatigue should be considered a valid term, even forhand instrumentation, in light of the fact that manymanufacturers are placing handles on files designed forrotational use.

From these studies, it seems that if the clinician ischanging from a high-torque instrument, such asstainless steel, to a low-torque instrument, such asnickel titanium, it would be wise to know that nickel-titanium instruments are more efficient and saferwhen used passively.

Although instrument breakage should be rare, anyinstrument, hand or rotary, can break. It is the clini-cian’s knowledge and experience, along with the manu-

Page 85: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 489

facturer’s quality control, that will ultimately minimizebreakage. At both the University of Tennessee andUniversity of California at Los Angeles, breakage has notincreased with the routine use of nickel-titaniuminstruments. If breakage occurs, the fractured piece canoccasionally be removed or bypassed using ultrasonicsand hand instruments in conjunction with magnifica-tion. The dentist having problems with file breakageshould seek help in evaluating his technique. Oneshould practice on extracted teeth until a level of confi-dence is reached that will help ensure safe and efficientpatient care.

The following is a list of situations that place nickel-titanium hand instruments at risk along with sugges-tions for avoiding problems:

Nickel-Titanium Precautions and Prevention

1. Often too much pressure is applied to the file. Neverforce a file! These instruments require a passivetechnique. If resistance is encountered, stop imme-diately, and before continuing, increase the coronaltaper and negotiate additional length, using a small-er, 0.02 taper stainless steel hand file. Stainless steelfiles should be used in sizes smaller than a No. 15. Ifone is using more finger pressure than that requiredto break a No. 2 pencil lead, too much pressure isbeing used. Break a sharp No. 2 pencil lead and seehow little pressure is required!

2. Canals that join abruptly at sharp angles are oftenfound in roots such as the mesiobuccal root of max-illary molars, all premolars, and mandibular incisorsand the mesial roots of mandibular molars. Thestraighter of the two canals should first be enlargedto working length and then the other canal, only towhere they join. If not, a nickel-titanium file mayreverse its direction at this juncture, bending backon itself and damaging the instrument.

3. Curved canals that have a high degree and smallradius of curvature are dangerous.138 Such curva-tures (over 60 degrees and found 3 to 4 mm fromworking length) are often seen in the distal canals ofmandibular molars and the palatal roots of maxil-lary first molars.

4. Files should not be overused! All clinicians haveexperienced more fracture after files have been useda number of times. Remember that all uses of a fileare not equal. A calcified canal stresses the file morethan an uncalcified canal. A curved canal stressesthe file more than a straight canal. One must alsobear in mind operator variability and the use oflubricants, which will affect stress.

Consider discarding a file after abusive use incalcified or severely curved canals even though ithas been used only in one tooth. Use new files inhard cases and older files in easier cases. No oneknows the maximum or ideal number of times a filecan be used. Follow manufacturers’ instructionsand the rule of being “better safe than sorry.” Onceonly is the safest number.

5. Instrument fatigue occurs more often during the ini-tial stages of the learning curve. The clinician chang-ing from stainless steel to nickel titanium should takecontinuing education courses with experienced clini-cians and educators, followed by in vitro practice onplastic blocks and extracted teeth. Break files inextracted teeth! Developing a level of skill and confi-dence allows one to use the technique clinically.

6. Ledges that develop in a canal allow space fordeflection of a file. The nickel-titanium instrumentcan then curve back on itself. A nickel-titaniuminstrument should not be used to bypass ledges.Only a small curved stainless steel file should beused, as described, in another section of this text.

7. Teeth with “S”-type curves should be approachedwith caution! Adequate flaring of the coronal thirdto half of the canal, however, will decrease problemsin these cases. It may also be necessary to gothrough a series of instruments an additional timeor two in more difficult cases.

8. If the instrument is progressing easily in a canal andthen feels as if it hits bottom, DO NOT APPLYADDITIONAL PRESSURE! This will cause theinstrument tip to bind. Additional pressure appliedat this point may cause weakening or even breakageof the instrument. In this situation, remove theinstrument and try a smaller, 0.02 taper handinstrument, either stainless steel or nickel-titanium,carefully flaring and enlarging the uninstrumentedapical portion of the canal.

9. Avoid creating a canal the same size and taper of theinstrument being used. The only exception is in theuse of the Buchanan GT file concept (to be dis-cussed later). On removal from the canal, the debrispattern on the file should be examined. Debrisshould appear on the middle portion of the file.Except for negotiating calcified canals and enlargingthe apical portion of the canal, the tip and coronalsection of the file should not carry debris. Avoidcutting with the entire length of the file blade. Thistotal or frictional fit of the file in the canal will causethe instrument to lock.

If this occurs, rotate the instrument in a counter-clockwise direction and remove it from the canal.

Page 86: Ch10: ENDODONTIC CAVITY PREPARATION

The greater the distance a single file is advanced intothe canal, the greater will be the chance of files “lock-ing up.” When the file feels tight throughout thelength of blade, it is an indication that the orifice andcoronal one-third to two-thirds of the canal needincreased taper. Instruments of varying designand/or taper can be used to avoid frictional fit.Nickel-titanium instruments with tapers from 0.04,0.06, and greater, as well as Gates-Glidden drills andsonic/ultrasonic instruments, serve this purpose well.

10. Sudden changes in the direction of an instrumentcaused by the operator (ie, jerky or jabbing move-ments) must be avoided. A smooth gentle reamingor rotary motion is most efficient.

11. As with any type of instrument, poor access prepa-ration will lead to procedural errors.

12. Advancing or pushing an instrument into a canal intoo large an increment causes it to act as a drill orpiston and greatly increases stress on the metal.Except for the most difficult cases and the necessityof using small instruments, the tip should not beused to cut into or drill into the canal; it should actonly as a guide. Regardless of the technique beingused, nickel-titanium instruments should beadvanced in small increments with a more passivepressure than that used with stainless steel.

13. Do not get in a hurry! Do not get in a hurry! Do notget greedy and try to make nickel titanium do morethan it is designed to do.

14. Inspection of instruments, particularly used instru-ments, by staff and doctor is critical. Prior to inser-tion and on removal, look at the blade. Rotate the file,looking for deflections of light. This indicates a dam-aged instrument. Also remember that, unlike stain-less steel, nickel titanium has an excellent memory.The file should be straight. If any bend is present, theinstrument is fatigued and should be replaced.

15. Do not assume that the length of files is always accu-rate; measure each file. Some files are longer fromhandle to tip than others. Files may also becomelonger or shorter if they are unraveled or twisted.

Comparative Studies

Nickel-titanium instruments function differently thanthose made of stainless steel, even when the cross-sec-tional design, taper, flutes, and tip are identical. In aneffort to compare hand nickel-titanium to stainlesssteel files, a series of studies were initiated at TheUniversity of Tennessee. Eighty-two second-year dentalstudents were required to instrument two epoxy blockscontaining curved canals. The only variable was the useof stainless steel files in one block and nickel-titanium

490 Endodontics

files in the second block. Standardized photographswere taken of the blocks before and after instrumenta-tion. Overlay tracings were made of these photographs,and differences in the shapes of the before and afterdrawings were measured.

The nickel-titanium blocks received a higher grade67.9% of the time and the stainless steel blocks 14.8%of the time. Working length was maintained signifi-cantly more often (p < .05) in the nickel-titaniumgroup than in the stainless steel group. There was noledging of canals using the more flexible nickel-titani-um files compared with 30.4% ledging when stainlesssteel files were used. When using nickel-titanium files,the students were short of working length in only 3% ofthe canals compared with 46% of the canals whenusing stainless steel files. Although the canals wereinstrumented beyond the intended working length in25% of the nickel-titanium blocks, the students wereable to develop an apical stop within 1 mm betweenworking length and the end of the canal. In the stain-less steel group, 6% of canals fell into this category. Thedegree of destruction around the foramen was signifi-cantly different (p < .05). Apical zipping occurred31.7% less often with the Nitinol files.139 Stripping ofthe canal walls was less with the nickel-titanium files. Asecond study in which the blocks were instrumented bya member of the faculty had similar findings.140

An observation from these studies was the creationof a smooth belly shape on the outer aspect of the api-cal third of the canals instrumented with nickel-titani-um instruments. This seemed to replace the ledgingthat occurred with stainless steel. Other studies haveshown that this may be attributable to the technique inwhich the files were used.

Are nickel-titanium hand instruments best used witha push-pull filing motion or with a reaming or rotarymotion? In one study, nickel-titanium files used in a fil-ing motion caused a significantly greater amount of theouter canal wall to be removed, between 3 and 6 mmshort of working length. The stainless steel files, howev-er, removed significantly more of the outer canal wall, atworking length and in the danger zone, than did therotary or hand nickel-titanium files. The rotary nickel-titanium files were significantly faster and maintainedbetter canal shape than the other groups. The results ofthis study indicate that nickel-titanium instrumentsshould be used with a rotational or reaming motionand are effective in shaping root canal systems.141

Using computed tomography, Gambill et al.reamed extracted teeth with either stainless steel ornickel-titanium files and reported that the nickel-tita-nium files caused less canal transportation, removed

Page 87: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 491

less dentin, were more efficient, and produced morecentered canals.142

On the other hand, not all studies are in agreementconcerning cutting efficiency. Tepel et al. tested 24brands of hand instruments specifically for cutting effi-ciency. They found that flexible stainless steel files weremore efficient than nickel titanium. However, they didnot address the quality of the completed canal.143

Elliot et al., at Guy’s Hospital in London, used resinblocks to compare stainless steel (Flexofiles) and nick-el-titanium (Nitiflex) instruments used with either abalanced force or stepback technique.144 The authorsconcluded that it is preferable to use nickel-titaniuminstruments in a balanced force technique and stainlesssteel in a filing technique because stainless steel files canbe precurved. Considering the results from Tennesseeand London, nickel-titanium instruments should beused as reamers, not files.

ISO Groups II and III

Engine-driven instruments can be used in three typesof contra-angle handpieces: a full rotary handpiece,either latch or friction grip, a reciprocating/quarter-turn handpiece, or a special handpiece that imparts avertical stroke but with an added reciprocating quarter-turn that “cuts in” when the instrument is stressed. Inaddition, there are battery-powered, slow-speed hand-pieces that are combined with an apex locator, designedto prevent apical perforations. Because the instrumentsused in these handpieces are generally designed for thetype of action delivered, it is best to describe the hand-piece before discussing their instruments.

Rotary Contra-angle Handpiece Instruments.Instrumentation with a full rotary handpiece is bystraight-line drilling or side cutting. Mounted withround or tapered burs or diamond points, full rotarycontra-angle handpieces can be used to develop coro-nal access to canal orifices. In addition, special reamers,listed under ISO Group II, may be used to funnel outorifices for easier access, to clean and shape canals withslow-turning nickel-titanium reamer-type instru-ments, and to prepare post channels for final restora-tion of the tooth.

Since some of these instruments (stainless) do notreadily bend, they should be used in perfectly straightcanals. Because they are often misdirected or forcedbeyond their limits, they notoriously cause perfora-tions or break in the hands of neophytes.

One solution to these problems is to use a slower hand-piece: the Medidenta/Micro Mega MM 324 reductiongear Handpieces (Medidenta/Micro Mega, Woodside,N.Y.), the Aseptico Electric Motor Handpiece (Aseptico

International, Woodinville, Wash.), the Quantec ETMElectric torque control motor (Sybron-Endo; Irving,Calif.), and the Moyco/Union Broach Sprint EDMElectronic Digital Motor handpiece (Miller Dental;Bethpage, N.Y.). These electric motors are specificallydesigned to power the new nickel-titanium instrumentsin canal preparation. The speeds vary from 300 rpm sug-gested for the NiTi ProFiles (Tulsa Dental; Tulsa, Okla.)to2,000 rpm recommended for the LightSpeed instruments.

Newer electric handpieces are available wherein notonly the speed can be controlled but the torque as well,that is, the speed and torque can be set for a certain sizeinstrument and the handpiece will “stall” and reverse ifthe torque limit is exceeded. Emerging as contenders inthis field are the new Aseptico ITR Motor handpiece(Aseptico International; Woodinville, Wash.), the NouvagTCM ENDO motor (Nouvag, Switzerland), the newEndo-Pro Electric (Medidenta/MicroMega; Woodside,N.Y.), and the new ProTorq motor handpiece (MicroMotors Inc; Santa Ana, Calif.).

An entirely new “wrinkle” in rotary handpieces is theMorita Tri Auto-ZX (J. Morita USA Inc. Irvine, CA), acordless, battery-powered, endodontic, slow-speed (280rpm) handpiece with a built-in apex locator. It usesrotary nickel-titanium instruments held by a push-but-ton chuck. The Tri Auto-ZX has three automatic func-tions: The handpiece automatically starts when the fileenters the canal and stops when the file is removed. Iftoo much pressure is applied, the handpiece automati-cally stops and reverses rotation. It also automaticallystops and reverses rotation when the file tip reaches theapical stop, as determined by the build-in apex locator.The Tri Auto-ZX will work in a moist canal.

Reciprocating Handpiece. A commonly used flatplane reciprocating handpiece is the Giromatic(Medidenta/MicroMega; Woodside, N.Y.). It accepts onlylatch-type instruments. In this device, the quarter-turnmotion is delivered 3,000 times per minute. More recent-ly, Kerr has introduced the M4 Safety Handpiece (Sybron-Kerr; Orange, Calif.), which has a 30-degree reciprocatingmotion and a unique chuck that locks regular hand files inplace by their handles (Figure 10-30). The Kerr Companyrecommends that their Safety Hedstrom Instrument beused with the M4. Zakariasen et al. found the M4, mount-ed with Safety Hedstrom files, to be somewhat superior to“step-back hand preparations and a shorter time of prepa-ration.”145,146 German researchers found much the samefor both the M4 and the Giromatic.147

The Endo-Gripper (Moyco/Union Broach; Bethpage,N.Y.) is a similar handpiece, with a 10:1 gear ratio and a45-degree turning motion. As with the Kerr M4, theEndo-Gripper also uses regular hand, not contra-angle,

Page 88: Ch10: ENDODONTIC CAVITY PREPARATION

instruments. Union Broach recommends their Flex-Rand Onyx-R files.

The Giromatic handpiece probably got off to a badstart because of the instruments initially used.Broaches proved less than effective. Then Hedstroem-type files were introduced followed by K-style ream-ers.148–152 Today, Micro Mega recommends theirRispiSonic or Triocut as the instruments of choice.

In any event, as the cutting instruments improved, anumber of well-known endodontists “came out of thecloset,” so to speak, admitting that they often used thesereciprocating instruments. The reports were mixed,however, between “zipping” at the apical foramen ver-sus round, tapered preparations.153–156

Vertical Stroke Handpiece. Levy introduced ahandpiece that is driven either by air or electrically thatdelivers a vertical stroke ranging from 0.3 to 1 mm. Themore freely the instrument moves in the canal, thelonger the stroke. The handpiece also has a quarter-turn reciprocating motion that “kicks in,” along with

492 Endodontics

the vertical stroke, when the canal instrument is underbind in a tight canal. If it is too tight, the motion ceas-es, and the operator returns to a smaller file. Developedin France, the Canal Finder System (Marseille, France)uses the A file, a clever variation of the H file.

ROTARY INSTRUMENTS

Two of the most historic and popular engine-driveninstruments are Gates-Glidden drills and Peeso ream-ers (drills) (Figure 10-31, A and B).

Gates-Glidden drills are an integral part of newinstrumentation techniques for both initial opening ofcanal orifices and deeper penetration in both straightand curved canals. Gates-Glidden drills are designed tohave a weak spot in the part of the shaft closest to thehandpiece so that, if the instrument separates, the sep-arated part can be easily removed from the canal. Theycome in sizes 1 through 6, although these sizes arebeing converted to the ISO instrument sizes and colors.

In a laboratory study, Leubke and Brantley tested twobrands of Gates-Glidden drills by clamping the head ofthe drill and then twisting the handles either clockwiseor counterclockwise. There was no specific pattern totheir fracture except that some broke at the head andsome high on the shaft near the shank.157 Luebke andBrantley later repeated the experiment, allowing thedrill head to turn as it would in a clinical situation. This

Figure 10-30 The M4 Safety Handpiece reciprocates in a 30-degree motion and locks regular hand files in place. The manufac-turer recommends that Safety Hedstrom files be used. (Courtesy ofSybron-Endo/Kerr, Orange, Calif.)

Figure 10-31 Engine-driven instruments used in a slow-speedhandpiece. A, Gates-Glidden drills come in sizes 1 through 6, endcutting or non–end cutting, and are used extensively in enlargingthe straight part of the canal. B, Peeso reamer (drill) used primari-ly for post preparation. C, New Orifice Opener, in instrument sizes25 through 70, used in the straight part of the canal. (Courtesy ofDentsply/Maillefer.)

Page 89: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 493

time, all of the drills fractured near the shank, “a majordeparture from the previous test.”158,159

The Peeso reamer (Dentsply/Maillefer; Tulsa, Okla.)is most often used in preparing the coronal portion ofthe root canal for a post and core. One must be carefulto use the “safe-ended” Peeso drill to prevent lateralperforation. Gutta-percha should have previously beenremoved to post depth with a hot plugger. Round bursshould never be used.

The use of rotary instruments will be described inthe instrumentation section. If used correctly, they canbe a tremendous help in facilitating instrumentation.

Rotary K-Type, U-Type, H-Type,and Drill-Type Instruments

As previously stated, the same instrument designsdescribed for hand instruments are available as rotary-powered instruments. To think this a new idea, one hasonly to return to a year 1912 catalog to learn that rotaryinstruments were being used nearly a century ago, K-style rotary “broaches” (reamers) made of carbon steel(Figure 10-32). At that early time, the probability oftheir breakage was precluded by the very slow speed ofthe treadle-type, foot-powered handpieces.

Today, at speeds that vary from 300 to 2,500 rpm,and with the growing use of nickel-titanium instru-ments, rotary canal preparation is once again very

much in vogue. Although the K-style configuration isstill widely used, the rotary U-style (ProFile) and drillstyle (Quantec) instruments are proving ever morepopular. The use of these instruments will be describedlater in the chapter.

Ultrasonic and Sonic Handpieces

Instruments used in the handpieces that move near orfaster than the speed of sound range from standard K-type files to special broach-like instruments.“Ultrasonic endodontics is based on a system in whichsound as an energy source (at 20 to 25 kHγ) activatesan endodontic file resulting in three-dimensional acti-vation of the file in the surrounding medium.”160 Themain débriding action of ultrasonics was initiallythought to be by cavitation, a process by which bubblesformed from the action of the file, become unstable,collapse, and cause a vacuum-like ‘implosion.’ A com-bined shock, shear and vacuum action results.”160

Ultrasonic handpieces use K files as a canal instru-ment. Before a size 15 file can fully function, however,the canal must be enlarged with hand instruments to atleast a size 20.

Although Richman must be credited with the first use(1957) of ultrasonics in endodontics,161 Martin andCunningham were the first to develop a device, test it, andsee it marketed in 1976.162–171 Ultimately named the

Figure 10-32 Historical illustration of Kerr Engine Drills, circa 1912. The shape of the drills resembles present-day K-style reamers. Madeof carbon steel, they were probably safe to use in straight canals with a slow, treadle-type, foot-powered handpiece. (Courtesy of Kerr DentalManufacturing Co., 1912 catalog.)

Page 90: Ch10: ENDODONTIC CAVITY PREPARATION

Cavitron Endodontic System (Dentsply/Caulk; York,Pa.), (Figure 10-33), it was followed on the market by theEnac unit (Osada Electric Co., Los Angeles, Calif.) andthe Piezon Master 400 (Electro Medical Systems, SA,Switzerland), as well as a number of “copycat” devices.

These instruments all deliver an irrigant/coolant,usually sodium hypochlorite, into the canal spacewhile cleaning and shaping are carried out by a vibrat-ing K file.

The results achieved by the ultrasonic units haveranged from outstanding162–183 to disappointing.184–189

Surely, there must be an explanation for such wide vari-ance in results.

The answer seems to lie in the extensive experimen-tation on ultrasonic instruments carried out, principal-ly at Guy’s Hospital in London. They thoroughly stud-ied the mechanisms involved and questioned the rolethat cavitation and implosion play in the cleansing

494 Endodontics

process.190–192 They believe that a different physicalphenomenon, “acoustic streaming,” is responsible forthe débridement. They concluded that “transient cavi-tation does not play a role in canal cleaning with theCaviEndo unit; however, acoustic streaming doesappear to be the main mechanism involved.”190 Theypointed out that acoustic streaming “depends on freedisplacement amplitude of the file” and that the vibrat-ing file is “dampened” in its action by the restrainingwalls of the canal.

The Guy’s Hospital group found that the smaller filesgenerated greater acoustic streaming and hence muchcleaner canals. After canals are fully prepared, by what-ever means, they recommended returning with a fullyoscillating No. 15 file for 5 minutes with a free flow of1% sodium hypochlorite.191 In another study, the Guy’sHospital group found that root canals had to beenlarged to the size of a No. 40 file to permit enough

Figure 10-33 A, CaviEndo unit with handpiece (right) andreservoir hatch (top right). Dials (front panel) regulate vibratorysettings. Foot control not shown. B, CaviEndo handpiece mount-ed with an Endosonic diamond file. Irrigating solution emitsthrough a jet in the head. (Courtesy of Dentsply/Cavitron.)

A

B

Page 91: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 495

clearance for the free vibration of the No. 15 file at fullamplitude.192 Others, including Martin, the developer,have recommended that the No. 15 file be used exclu-sively.165,174,186 The efficacy of ultrasonography to thor-oughly débride canals following step-back preparationwas dramatically demonstrated by an Ohio State/USNavy group. There was an enormous difference incleanliness between canals merely needle-irrigated dur-ing preparation and those canals prepared and followedby 3 minutes of ultrasonic instrumentation with a No.15 file and 5.25% sodium hypochlorite.193

Another British group reached similar conclusionsabout the oscillatory pattern of endosonic files.194

These researchers pointed out that the greatest dis-placement amplitude occurs at the unconstrained tipand that the greatest restraint occurs when the instru-ment is negotiating the apical third of a curved canal.This is the damping effect noted by the Guy’s Hospitalgroup, the lack of freedom for the tip to move freely toeither cut or cause acoustic streaming to cleanse.190

Krell at The University of Iowa observed the same phe-nomenon, that the irrigant could not advance to theapex “until the file could freely vibrate.”195 The Britishresearchers also reported better results if K files wereprecurved when used in curved canals.196

At Guy’s Hospital, another interesting phenomenonwas discovered about ultrasonic canal preparation—that,contrary to earlier reports,170 ultrasonics alone actuallyincreased the viable counts of bacteria in simulated rootcanals.197 This was felt to be caused by the lack of cavita-tion and the dispersal effects of the bacteria by acousticstreaming. On substitution of sodium hypochlorite

(2.5%) for water, however, all of the bacteria were killed,proving once again the importance of using an irrigatingsolution with bactericidal properties.197

Ahmad and Pitt Ford also pitted one ultrasonic unitagainst the other—CaviEndo versus Enac.198 Theyevaluated canal shape and elbow formation: “There wasno significant difference…in the amount of apicalenlargement.” They did find, however, that the Enacunit had a greater propensity for producing “elbows,” aswell as apical deviation and change of width.198

Ahmad, at Guy’s Hospital, suggested that “the man-ufacturers of ultrasonic units consider different filedesigns.” She found the K-Flex to be more efficient thanthe regular K style.199

Ultrasonic Conclusions

One can draw the conclusion that ultrasonic endodon-tics has added to the practice of root canal therapy.There is no question that canals are better débrided ifultrasonic oscillation with sodium hypochlorite isused at the conclusion of cavity preparation. But thefiles must be small and loose in the canal, particularlyin curved canals, to achieve optimum cleansing.

Sonic Handpieces

The principal sonic endodontic handpiece availabletoday is the Micro Mega 1500 (or 1400) Sonic Air EndoSystem (Medidenta/ Micro Mega) (Figure 10-34). Likethe air rotor handpiece, it attaches to the regular airlineat a pressure of 0.4 MPa. The air pressure may be var-ied with an adjustable ring on the handpiece to give anoscillatory range of 1,500 to 3,000 cycles per second.

Figure 10-34 Micro Mega 1500Sonic Air handpiece. Activated bypressure from the turbine air supply,the Micro Mega1500 can be mountedwith special instruments easily adjust-ed to the length of the tooth. Waterspray serves as an irrigant. (Courtesyof Medidenta/Micro Mega.)

Page 92: Ch10: ENDODONTIC CAVITY PREPARATION

Tap water irrigant/coolant is delivered into the prepa-ration from the handpiece.

Walmsley et al., in England, studied the oscillatorypattern of sonically powered files. They found that outin the air, the sonic file oscillated in a large ellipticalmotion at the tip. When loaded, as in a canal, however,they were pleased to find that the oscillatory motionchanged to a longitudinal motion, up and down, “aparticularly efficient form of vibration for the prepara-tion of root canals.”200

The strength of the Micro Mega sonic handpiece liesin the special canal instruments used and the ability tocontrol the air pressure and hence the oscillatory pattern.

The three choices of file that are used with the MicroMega 1500 are the RispiSonic, developed by Dr. RetanoSpina in Italy, the Shaper Sonic (Medidenta; Woodside,N.Y.), developed by Dr. J. M. Laurichesse in France, andthe Trio Sonic (Medidenta; Woodside, N.Y.) (also calledin Europe the Heliosonic and the Triocut File) (Figure10-35). The Rispi Sonic resembles the old rat-tail file. TheShaperSonic resembles a husky barbed broach. TheTrioSonic resembles a triple-helix Hedstroem file. All ofthese instruments have safe-ended noncutting tips.

The RispiSonic has 8 cutting blades and the ShaperSonic has 16. The ISO sizes range from 15 to 40.Because graduated-size instruments have varying shaftsizes, the instrument must be tuned with the unit’s tun-ing ring to an optimum tip amplitude of 0.5 mm.

As with the ultrasonic canal preparation, theseinstruments must be free to oscillate in the canal, to raspaway at the walls, and to remove necrotic debris andpulp remnants. To accommodate the smallest instru-ment, a size 15, the canal must be enlarged to the work-ing length with hand instruments through size No. 20.The sonic instruments, with the 1.5 to 2.0 mm safe tips,begin their rasping action this far removed from theapical stop. This is known as the “sonic length.” As theinstrument becomes loose in the canal, the next-sizeinstrument is used, and then the next size, which devel-ops a flaring preparation. The sonic instruments areprimarily for step-down enlarging, not penetration.

Cohen and Burns emphasized the three objectives ofshaping the root canal: “(a) developing a continuoustapering conical form; (b) making the canal narrowapically with the narrowest cross-sectional diameter atits terminus, and (c) leaving the apical foramen in itsoriginal position spatially.”201

To satisfy these requirements, two of the sonicinstruments have been quite successful. At the dentalschool in Wales, Dummer et al. found the Rispi Sonicand Shaper Sonic files to be the most successful, theTrio Sonic less so202: “In general, the Shaper Sonic files

496 Endodontics

widened the canals more effectively than the RispiSonic files, whilst the Heliosonic [Trio Sonic] files wereparticularly ineffective…”202

The research group at Temple University foundessentially the same results. They recommended thatthe Shaper Sonic files be used first and that the remain-ing two-thirds of the canal be finished with the RispiSonic.203 Ehrlich et al. compared canal apical transportusing Rispi Sonic and Trio Sonic files versus handinstrumentation with K files.204 They found no differ-ence in zipping among the three instruments. Even theworst transport was only 0.5 mm. Tronstad andNiemczyk also tested the Rispi and Shaper files againstother instruments. They reported no complications(broken instruments, perforations, etc) with either ofthe Sonic instruments.205 Miserendino et al. also foundthat the “Micro Mega sonic vibratory systems usingRispi Sonic and Shaper files were significantly moreefficient than the other systems tested.”206

Comparisons in Efficacy and Safety of AutomatedCanal Preparation Devices

Before making an investment in an automatedendodontic device, one should know the comparativevalues of the different systems and their instruments.

Figure 10-35 Three instruments used with the MM1500 Sonic Airhandpiece. A, RispiSonic. B, ShaperSonic. C, TrioSonic (akaHeliosonic or Triocut). (Courtesy of Medidenta/Micro Mega.)

A B C

Page 93: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 497

Unfortunately, the ultimate device and instrument hasnot been produced and tested as yet. Some are better incutting efficiency, some in following narrow curvedcanals, some in producing smooth canals, and some inirrigating and removing smear layer, but apparentlynone in mechanically reducing bacterial content.

As stated above, Miserendino et al. found that the cut-ting varied considerably. They ranked the RispiSonic fileat the top, followed by the ShaperSonic, the Enac “U” file(Osada Electric), and the CaviEndo K file.206

Tronstad and Niemczyk’s comparative study favoredthe Canal Finder System in narrow, curved canals. Onthe other hand, the Rispi and Shaper files in the MicroMega Sonic handpiece proved the most efficacious “inall types of root canals.” The Cavitron Endo System wasa disappointment in that it was so slow, blocked andledged the canals, and fractured three files in severelycurved canals. They also found the Giromatic withRispi files to be effective in wide straight canals, less soin curved canals, where four Rispi files fractured.205

Bolanos et al. also tested the Giromatic with Rispifiles against the Micro Mega Sonic handpiece withRispi and Shaper files. They found the RispiSonic bestin straight canals, the ShaperSonic best in curvedcanals, and both better than the Giromatic/Rispiand/or hand instrumentation with K-Flex files. TheShaper files left the least debris and the Giromatic/Rispileft “an extensive amount of debris.”203

Kielt and Montgomery also tested the Micro MegaSonic unit with TrioSonic files against the ultrasonicCavitron Endo and Enac units with K files.207 Eventhough others found the Trio Sonic files less effective(than the Rispi or Shaper files),204 Kielt andMontgomery concluded that “overall the Medidentaunit was superior to the other endosonic systems andto the hand technique (control).”207 The Zakariasengroup at Dalhousie University reported unusual suc-cess in combining hand instrumentation with sonicenlargements using the Micro Mega 1500.208

Walker and del Rio also compared the efficacy of theCavitron Endo and Enac ultrasonic units against theMicro Mega Sonic unit and found “no statistically sig-nificant difference among the groups, however, liquidextruded from the apical foramen in 84% of their testteeth. They felt that “sodium hypochlorite mayimprove the débridement of the canal.” They also didnot test the Rispi or Shaper Sonic files.209

At the University of Minnesota, the ultrasonic unitswere again tested against the sonic unit. The researchersfound the Micro Mega Sonic to be the fastest in prepa-ration time and caused the “least amount of straighten-ing of the canals.”210 On the other hand, Reynolds et al.,

at Iowa, found hand preparation with the step-backtechnique superior to sonic and ultrasonic preparationexcept in the important apical area, where they weresimilar.211 The Iowa group also found that ultrasonicand sonic files best cleaned ovoid canals.212

Lev et al. prepared the cleanest canals using thestep-back technique followed by 3-minute use of aCaviEndo ultrasonic file with sodium hypochlorite.213

This approach has become an optimum and standardprocedure for many endodontists.

Stamos et al. also compared cleanliness followingultrasonic débridement with sodium hypochlorite ortap water. Using water alone, the Enac system was moreeffective, but when sodium hypochlorite was used, theCaviEndo unit (which has a built-in tank) was superi-or. They also reported ultrasonic preparation to be“significantly faster” than hand instrumentation.214

A US Army research group tested sonic versus ultra-sonic units and concluded that they were all effective incanal preparation but judged the Micro Mega Sonic AirSystem, using Rispi and Shaper Sonic files, “as the bestsystem tested.”215

Fairbourn et al. compared four techniques accord-ing to the amount of debris extruded from the apex.The sonic technique extruded the least and handinstrumentation the most debris. Ultrasonic washalfway between.216 Whether the debris dischargedinto the apical tissue contains bacteria was of theutmost importance. Using sterile saline as an irrigant,Barnett et al. found sodium hypochlorite to be fourtimes more effective than sterile saline.217 A US Navygroup found essentially the same thing.218

Comparative Conclusion of Automated Devices.It appears safe to say that no one automated device willanswer all needs in canal cleaning and shaping. Handinstrumentation is essential to prepare and cleanse theapical canal, no matter which device, sonic or ultrason-ic, is used. The sonic unit Micro Mega 1500 reportedlyenlarges the canal the fastest when Rispi or Shaper filesare used, whereas the Canal Finder System, usingA-style files, leads in instrumenting narrow curvedcanals. Finally, the ultrasonic CaviEndo and Enac units,using small K files and half-strength sodium hypochlo-rite for an extended time (3 minutes), seem to débridethe canal best. No technique without sodiumhypochlorite kills bacteria, however.

One must evaluate one’s practice and decide whichdevice, no device, or all three best suit one’s needs.

ISO Group IV Filling Materials

An ADA specification has also been written for fillingmaterials—core materials such as gutta-percha and sil-

Page 94: Ch10: ENDODONTIC CAVITY PREPARATION

ver points, as well as sealer cements classified by theirchemical make-up and mode of delivery.

IRRIGATION

Chemomechanical Débridement

The pulp chamber and root canals of untreated nonvi-tal teeth are filled with a gelatinous mass of necroticpulp remnants and tissue fluid (Figure 10-36). Essentialto endodontic success is the careful removal of theseremnants, microbes, and dentinal filings from the rootcanal system. The apical portion of the root canal isespecially important because of its relationship to theperiradicular tissue. Although instrumentation of theroot canal is the primary method of canal débridement,irrigation is a critical adjunct. Irregularities in canal sys-tems such as narrow isthmi and apical deltas preventcomplete débridement by mechanical instrumentationalone. Irrigation serves as a physical flush to removedebris as well as serving as a bactericidal agent, tissuesolvent, and lubricant. Furthermore, some irrigants areeffective in eliminating the smear layer.

498 Endodontics

A potential complication of irrigation is the forcedextrusion of the irrigant and debris through the apex. Thisraises questions concerning the choice of irrigating solu-tion, the best method of delivering the irrigant, and thevolume of irrigant used. Other variables include how longthe solution is left in the canal, ultrasonic activation, tem-perature of the irrigant, and the effect of combining dif-ferent types of solutions. Although the presence of an irri-gant in the canal throughout instrumentation facilitatesthe procedure, there are specific lubricating agentsdesigned for that purpose: examples are RC Prep (PremierDental; King of Prussia, Pa.), GlyOxide (Smith KlineBeecham, Pittsburgh, Pa.), REDTAC (Roth International,Chicago, Ill.), and Glyde File Prep (Dentsply/Maillefer;Tulsa, Okla.). It is highly recommended that canals alwaysbe instrumented while containing an irrigant and/or alubricating agent. Instrumentation in this manner mayprevent the complication of losing contact with the meas-urement control owing to an accumulation of debris inthe apical segment of the canal.

Root Canal Irrigants

A wide variety of irrigating agents are available. It isrecommended that the practitioner understands thepotential advantages and disadvantages of the agent tobe used.

Sodium Hypochlorite. Sodium hypochlorite isone of the most widely used irrigating solutions.Household bleach such as Chlorox contains 5.25%sodium hypochlorite. Some suggest that it be used atthat concentration, whereas others suggest diluting itwith water, and still others alternate it with otheragents, such as ethylenediaminetetraacetic acid withcentrimide (EDTAC) (Roydent Products; RochesterHills, Mich.) or chlorhexidine (Proctor & Gamble,Cincinnati, Ohio). Sodium hypochlorite is an effectiveantimicrobial agent, serves as a lubricant during instru-mentation, and dissolves vital and nonvital tissue.Questions concerning the use of sodium hypochloriteare often focused on the appropriate concentration,method of delivery, and concern with cellular damagecaused by extrusion into the periradicular tissues.Researchers do not agree on the precise concentrationof sodium hypochlorite that is advisable to use.

Baumgartner and Cuenin, in an in vitro study, foundthat 5.25%, 2.5%, and 1.0% solutions of sodiumhypochlorite completely removed pulpal remnants andpredentin from uninstrumented surfaces of single-canalpremolars.219 Although 0.5% sodium hypochloriteremoved most of the pulpal remnants and predentinfrom uninstrumented surfaces, it left some fibrils on thesurface. They commented that “It seemed probable that

Figure 10-36 Gelatinous mass of necrotic debris should be elimi-nated from the pulp canal before instrumentation is started.Forcing this noxious infected material through the apical foramenmight lead to an acute apical abscess.

Page 95: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 499

there would be a greater amount of organic residuepresent following irrigation of longer, narrower, moreconvoluted root canals that impede the delivery of theirrigant.” This concern seems reasonable as the ability ofan irrigant to be distributed to the apical portion of acanal is dependent on canal anatomy, size of instru-mentation, and delivery system. Trepagnier et al. report-ed that either 5.25% or 2.5% sodium hypochlorite hasthe same effect when used in the root canal space for aperiod of 5 minutes.220

Spångberg et al. noted that 5% sodium hypochloritemay be too toxic for routine use.221 They found that0.5% sodium hypochlorite solution dissolves necroticbut not vital tissue and has considerably less toxicity forHeLa cells than a 5% solution. They suggested that0.5% sodium hypochlorite be used in endodontic ther-apy. Bystrom and Sundquist examined the bacteriolog-ic effect of 0.5% sodium hypochlorite solution inendodontic therapy.222 In that in vivo study, using 0.5%sodium hypochlorite, no bacteria could be recoveredfrom 12 of 15 root canals at the fifth appointment. Thiswas compared with 8 of 15 root canals when salinesolution was used as the irrigant. Baumgartner andCuenin also commented that “The effectiveness of lowconcentrations of NaOCl may be improved by usinglarger volumes of irrigant or by the presence of replen-ished irrigant in the canals for longer periods oftime.”219 On the other hand, a higher concentration ofsodium hypochlorite might be equally effective inshorter periods of time.

Siqueira et al., in an in vitro study, evaluated the effectof endodontic irrigants against four black-pigmentedgram-negative anaerobes and four facultative anaerobicbacteria by means of an agar diffusion test. A 4% sodi-um hypochlorite solution provided the largest averagezone of bacterial inhibition and was significantly supe-rior when compared with the other solutions, except2.5% sodium hypochlorite (p < .05). Based on the aver-ages of the diameters of the zones of bacterial growthinhibition, the antibacterial effects of the solution wereranked from strongest to weakest as follows: 4% sodiumhypochlorite; 2.5% sodium hypochlorite; 2% chlorhex-idine, 0.2% chlorhexidine EDTA, and citric acid; and0.5% sodium hypochlorite.223

The question of whether sodium hypochlorite isequally effective in dissolving vital, nonvital, or fixed tis-sue is important since all three types of tissue may beencountered in the root canal system. Rosenfeld et al.demonstrated that 5.25% sodium hypochlorite dis-solves vital tissue.224 In addition, as a necrotic tissue sol-vent, 5.25% sodium hypochlorite was found to be sig-nificantly better than 2.6%, 1%, or 0.5%.225 In another

study, 3% sodium hypochlorite was found to be optimalfor dissolving tissue fixed with parachlorophenol orformaldehyde.226 Clearly, the final word has not beenwritten on this subject.

Sodium Hypochlorite Used in Combination withOther Medicaments. Whether sodium hypochloriteshould be used alone or in combination with otheragents is also a source of controversy. There is increas-ing evidence that the efficacy of sodium hypochlorite,as an antibacterial agent, is increased when it is used incombination with other solutions, such as calciumhydroxide, EDTAC, or chlorhexidine. Hasselgren et al.found that pretreatment of tissue with calciumhydroxide can enhance the tissue-dissolving effect ofsodium hypochlorite.227

Wadachi et al., using 38 bovine freshly extractedteeth, studied the effect of calcium hydroxide on thedissolution of soft tissue on the root canal wall.228 Theyfound that the combination of calcium hydroxide andsodium hypochlorite was more effective than usingeither medicament alone.

However, Yang et al., using 81 freshly extracted humanmolars, examined the cleanliness of main canals andinaccessible areas (isthmi and fins) at the apical, middle,and coronal thirds.229 Complete chemomechanicalinstrumentation combined with 2.5% sodium hypochlo-rite irrigation alone accounted for the removal of mosttissue remnants in the main canal. Prolonged contactwith calcium hydroxide to aid in dissolving main canaltissue remnants after complete instrumentation was inef-fective. They also found that tissues in inaccessible areas(isthmi and fins) of root canals were not contacted by cal-cium hydroxide or sodium hypochlorite and were poorlydébrided. As they noted, however, it could be that theirstudy did not permit sufficient time (1 day or 7 days) forthe tissue to be degraded. Hasselgren et al. reported thatporcine muscle was completely dissolved after 12 days ofexposure to calcium hydroxide.227 The contrasting resultsof some investigators may be explained by their differentmethodologies including varied tissues studied, as well asa variety of delivery systems and the vehicle included inthe calcium hydroxide mix.

Other variables to be considered include temperatureas well as shelf life of the solution.230–232 Raphael et al.tested 5.25% sodium hypochlorite on Streptococcus fae-calis, Staphylococcus aureus, and Pseudomonas aerugi-nosa at 21˚C and 37˚C and found that increasing thetemperature made no difference on antimicrobial effi-cacy and may even have decreased it.233 Pseudomonasaeruginosa was particularly difficult to eliminate. Buttlerand Crawford, using Escherichia coli and Salmonellatyphosa, studied 0.58%, 2.7%, and 5.20% sodium

Page 96: Ch10: ENDODONTIC CAVITY PREPARATION

hypochlorite for its ability to detoxify endotoxin.234 Allthree concentrations were equally effective; however,large amounts of E. coli endotoxin could not be detoxi-fied by 1 mL of 0.58% or 2.7% sodium hypochlorite.How this relates to the clinical situation is uncertain.

Against most anaerobic bacteria, Byström andSundqvist found 5.0% and 0.5% sodium hypochloriteequally effective. By combining 5.0% sodium hypochlo-rite with EDTA, however, the bactericidal effect was con-siderably enhanced. This could be related to the removalof the contaminated smear layer by EDTA.235

Fischer and Huerta believe that it is the alkaline prop-erty (pH 11.0 to 11.5) of sodium hypochlorite that makesit effective against anaerobic microbes,236 and a US Armygroup found full-strength sodium hypochlorite to beeffective in 5 minutes against obligate anaerobes.237

Possibly, the bactericidal effect gained by combiningsodium hypochlorite with other chemicals comes fromthe release of chlorine gas. This was especially true ofcitric acid and to some extent with EDTA, but not withperoxide.238

Sodium hypochlorite is a tissue irritant, and this hasdeterred its use, particularly at full strength. There is noquestion that, forced out the apex, most irrigants canbe destructive. This will be discussed in detail in chap-ter 14 on mishaps.

Other Irrigants. Salvizol (Ravensberg Konstanz,Germany) is a root canal chelating irrigant, N1-

500 Endodontics

decamethylene-bis-4-aminoquinaldinium-diacetate.Kaufman et al. have suggested that Salvizol, with a neu-tral pH, has a broad spectrum of bactericidal activity andthe ability to chelate calcium. This gives the product acleansing potency while being biologically compatible239

(Figure 10-37). This applies to Tublicid (green, red, andblue) (Dental Therapeutics AB, Sweden) as well.

Chlorhexidine gluconate is an effective antimicrobialagent, and its use as a endodontic irrigant has been welldocumented.240–242 It possesses a broad-spectrumantimicrobial action,243 substantivity,244 and a relativeabsence of toxicity.241 However, chlorhexidine gluconateis not known to possess a tissue-dissolving property.238

The results from the individual trial of chlorhexi-dine gluconate and sodium hypochlorite indicate thatthey are equally effective antibacterial agents. However,when Kuruvilla and Kamath combined the solutionswithin the root canal, the antibacterial action was sug-gestive of being augmented.245

The results of their study indicate that the alternateuse of sodium hypochlorite and chlorhexidine glu-conate irrigants resulted in a greater reduction ofmicrobial flora (84.6%) when compared with the indi-vidual use of sodium hypochlorite (59.4%) orchlorhexidine gluconate (70%) alone.245

White et al. found that chlorhexidine instills effec-tive antimicrobial activity for many hours after instru-mentation.246 Although sodium hypochlorite is equal-

Figure 10-37 A, Coronal portion of a root canal of a tooth treated in vivo with Salvizol. The canal wall is clean, and very small pulpal tis-sue remnants are present; the tubules are open, and many intertubular connections with small side branches are visible. B, Middle portionof root canal treated with Salvizol. Note the tridimensional framework arrangement of tubular openings. Very little tissue debris is present.Intratubular connections are clearly seen. Reproduced with permission from Kaufman AY et al.239

A B

Page 97: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 501

ly effective on initial exposure, it is not a substantiveantimicrobial agent.

Kaufman reported the success of several cases usingbis-dequalinium acetate (BDA) as a disinfectant andchemotherapeutic agent247 He cited its low toxicity,lubrication action, disinfecting ability, and low surfacetension, as well as its chelating properties and low inci-dence of post-treatment pain.

Others have pointed out the efficacy of BDA. In onereport, it was rated superior to sodium hypochlorite indébriding the apical third.248 When marketed asSolvidont (Dentsply/DeTrey, Switzerland), theUniversity of Malaysia reported a remarkable decreasein postoperative pain and swelling when BDA was used.They attributed these results to the chelation propertiesof BDA in removing the smear layer coated with bacte-ria and contaminants as well as the surfactant propertiesthat allow BDA “to penetrate into areas inaccessible toinstruments.”249 Bis-dequalinium acetate is recom-mended as an excellent substitute for sodium hypochlo-rite in those patients who are allergic to the latter.Outside North America, it enjoys widespread use.

A Loyola University in vitro study reported that full-strength Clorox (sodium hypochlorite) and Gly-Oxide(urea peroxide), used alternately, were 100% effectiveagainst Bacteroides melaninogenicus, which has beenimplicated as an endodontic pathogen. Alternatingsolutions of sodium hypochlorite and hydrogen perox-ide cause a foaming action in the canal through therelease of nascent oxygen. Hydrogen peroxide (3%)alone also effectively “bubbles” out debris and mildlydisinfects the canal. In contrast, Harrison et al. haveshown that using equal amounts of 3% hydrogen per-oxide and 5.25% sodium hypochlorite inhibited theantibacterial action of the irrigants.250 Because of thepotential for gaseous pressure from residual hydrogenperoxide, it must always be neutralized by the sodiumhypochlorite and not sealed in the canal.

It must be understood that each of the studies citedabove has examined limited test results concerning theuse of various irrigants or combinations of irrigants.However, there are other factors aside from the solutionused. For example, Ram pointed out that the irriga-tional removal of root canal debris seems to be moreclosely related to canal diameter than to the type ofsolution used.251 This, in turn, must be related to theviscosity or surface tension of the solution, the diame-ter and depth of penetration of the irrigating needle,the volume of the solution used, and the anatomy ofthe canal.

Ultrasonic Irrigation. As stated previously, the useof ultrasonic or sonic irrigation to better cleanse root

canals of their filings, debris, and bacteria, all the way tothe apex, has been well documented by Cunningham etal.168,169 as well as others. More recently, they have beenjoined by a number of clinicians reporting favorableresults with ultrasonic/sonic irrigation, from thorough-ly cleansing the walls in necrotic open apex cases, 252 toremoving the smear layer.253 Griffiths and Stock pre-ferred half-strength sodium hypochlorite to Solvidontin débriding canals with ultrasound.254 Sjögren andSundqvist found that ultrasonography was best in elim-inating canal bacteria but still recommended the “use ofan antibacterial dressing between appointments.255

Others were not as impressed.256,257 In fact, onegroup found sodium hypochlorite somewhat betterthan tap water when used with ultrasonography butalso noted that both irrigants were ineffective “inremoving soft tissue from the main canal, the isthmusbetween canals, the canal fins, and the multiplebranches or deltas.”252 However, they used ultrasonicsfor only 3 minutes with a No. 15 file and 1 minutewith a No. 25 diamond file.252 As Druttman and Stockpointed out, “with the ultrasonic method, resultsdepended on irrigation time.”258 As previously noted,the cleanest canals are achieved by irrigating withultrasonics and sodium hypochlorite for 3 minutesafter the canal has been totally prepared (Figure 10-38). Moreover, ultrasonics proved superior to syringeirrigation alone when the canal narrowed to 0.3 mm(size 30 instrument) or less.259 Buchanan noted that itis the irrigants alone that clean out the accessorycanal. Instruments cannot reach back into these pas-sages. Only the copious use of a tissue-dissolving irri-gant left in place for 5 to 10 minutes repeatedly willensure auxiliary canal cleaning.260

Figure 10-38 Irrigating solution climbs the shaft of a CaviEndovibrating No. 15 file to agitate and débride unreachable spaces inthe canal. (Courtesy of Dentsply/Cavitron.)

Page 98: Ch10: ENDODONTIC CAVITY PREPARATION

Method of Use

Although the technique for irrigation is simple, thepotential for serious complications exists. Regardless ofthe delivery system, the solution must be introducedslowly and the needle never wedged in the canal. Thegreatest danger exists from forcing the irrigant andcanal debris into the periradicular tissue owing to a pis-ton-like effect. Several types of plastic disposablesyringes are available.

Usually, the irrigating solution is kept in a dappendish that is kept filled. The syringe is filled by immers-ing the hub into the solution while withdrawing theplunger. The needle, or probe in the case of theProRinse (Dentsply/Tulsa Dental; Tulsa, Okla.), is thenattached. Care must be taken with irrigants like sodiumhypochlorite to prevent accidents. Sodium hypochlo-rite can be irritating to the eyes, skin, and mucousmembranes. Some practioners provide protectiveglasses to their patients to protect their eyes. Also, it canruin clothing.

The irrigating needle may be one of several types. Itshould be bent to allow easier delivery of the solutionand to prevent deep penetration of the needle or probe(see Figure 10-38). A commonly used needle is the 27-gauge needle with a notched tip, allowing for solutionflowback (see Figure 10-39, insert), or the blunt-endProRinse. It is strongly recommended that the needle liepassively in the canal and not engage the walls. Severecomplications have been reported from forcing irrigat-ing solutions beyond the apex by wedging the needle inthe canal and not allowing an adequate backflow.261 Thisis an important point in view of results suggesting thatthe proximity of the irrigation needle to the apex playsan important role in removing root canal debris.262

Moser and Heuer reported Monoject endodontic nee-dles (Tyco/Kendall; Mansfield, Mass.) to be the most effi-cient delivery system in which longer needles of a blunt-ed, open-end system were inserted to the full length ofthe canal.263 The point is that a larger volume of solutioncan be delivered by this method. However, the closer theneedle tip is placed to the apex, the greater the potentialfor damage to the periradicular tissues. Druttman andStock found much the same results, that with “conven-tional methods, irrigation performance varied with thesize of the needle and volume of irrigant.”258

Walton and Torabinejad stated that “Perhaps themost important factor is the delivery system and notthe irrigating solution per se.” Furthermore, it wasfound that the volume of the irrigant is more importantthan the concentration or type of irrigant.264 Chowfound that there was little flushing beyond the depth ofthe needle, unless the needle was “bound” in the canal

502 Endodontics

and the irrigant forcibly expressed.265 Wedging a needlein a canal is dangerous and can cause serious sequelae.

Canal size and shape are crucial to the penetration ofthe irrigant. The apical 5 mm are not flushed until theyhave been enlarged to size 30 and more often size 40file.266,267 It is reported that “In order to be effective,the needle delivering the solution must come in closeproximity to the material to be removed.”262 Small-diameter needles were found to be more effective inreaching adequate depth but were more prone to prob-lems of possible breakage and difficulty in expressingthe irrigant from the narrow needles.262 Of course, thecloser the needle is to the apical foramen, the morelikely it is that solution will be extended into the peri-radicular tissues.

Kahn, Rosenberg et al. at New York University, in anin vitro study, tested various methods of irrigating thecanal. Evaluated were Becton-Dickinson (BD), (FranklinLake, N.J.) 22-gauge needles; Monoject endodontic nee-dles, 23 and 27 gauge (Tyco/Kendall, Mansfield, Mass.)(Figure 10-39); ProRinse 25-, 28-, and 30-gauge probes(Dentsply/Tulsa Dental; Tulsa, Okla); CaviEndo ultra-

Figure 10-39 Simplest endodontic irrigating system—plastic dis-posable syringe and needle. Note that the needle is loose in thecanal to allow backflow. Notched needle tip (inset) eliminates pres-sure (Monoject).

Page 99: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 503

sonic handpiece (Dentsply/Caulk, York, Pa.); and theMicroMega 1500; Woodside, N.Y.). Canals in plasticblocks were filled with food dye and instrumented toprogressively larger sizes.

ProRinse probes were highly effective in all gaugesand in all sizes of canals tested. In canals instrumentedto size 30 K file and size 35 K file, the smaller-lumen 27-gauge notch-tip needle was found to be highly effective.The larger 23-gauge notch-tip needle was found to berelatively ineffective, as was the standard 22-gaugebeveled needle.

The Micromega 1500 and CaviEndo systems werehighly effective at the size 20, 25, and 30 K-file levels.Recapitulation, with smaller-sized vibrating files, com-pletely cleared dye from the few apical millimeters.

The zones of clearance beyond the tip of theProRinse probes were significant in that they indicatedthat highly effective canal clearance occurred withouthaving to place the tip of the probes at the apicalforamina. The effectiveness of the ProRinse seemedrelated to its design. It has a blunt tip, with the lumen 2mm from the tip. Expression of fluid through thelumen creates turbulence around and beyond the endof the probe (Figure 10-40).

This model system was created to enable the inves-tigators, using a Sony camcorder, to observe the dif-ferences of different irrigating systems. However,there are inherent differences in the in vitro test modelfrom the in vivo situation. In vivo variables that affectdelivery of the irrigant are canal length and quality ofinstrumentation. In vitro results, although potentiallyvaluable, cannot be directly extrapolated to the in vivosituation.

Removal of the Smear Layer

Organic Acid Irrigants. The use of organic acids toirrigate and débride root canals is as old as root canaltherapy itself. More recently, though, it has been inves-tigated by Tidmarsh, who felt that 50% citric acid gavethe cleanest dentin walls without a smear layer268

(Figure 10-41). Wayman et al. also reported excellentfilling results after preparation with citric acid (20%),followed by 2.6% sodium hypochlorite and a finalflushing with 10% citric acid.269

In two separate studies, the US Army reported essen-tially the same results. Both studies, however, empha-sized the importance of recapitulation—re-instrumen-tation with a smaller instrument following each irriga-tion.270,271 Not to be outdone, the US Air Force testedboth citric acid and sodium hypochlorite againstanaerobic bacteria. They reported them equally effec-tive as a bactericide in 5 to 15 minutes.272

Figure 10-40 ProRinse needles irrigate through a side vent. A,Douching spray reaches all regions of the canal by rotating the nee-dle. B, Closed-end needle eliminates possibilities of puncture of theapical foramen or a “water cannon” effect from open-end needles.(Courtesy of Dentsply/Tulsa Dental.)

A

B

Page 100: Ch10: ENDODONTIC CAVITY PREPARATION

Other organic acids have been used to remove thesmear layer: polyacrylic acid as Durelon and Fuju II liq-uids, both 40% polyacrylic acid.273

Chelating Agents. The most common chelatingsolutions used for irrigation include Tublicid, EDTA,EDTAC, File-Eze, and RC Prep, in all of which EDTA isthe active ingredient. Nygaard-Østby first suggested theuse of EDTA for cleaning and widening canals.274 Later,Fehr and Nygaard-Østby introduced EDTAC (N-O

504 Endodontics

Therapeutics Hd, Sweden), quaternary ammoniumbromide, used to reduce surface tension and increasepenetration.275 The optimal pH for the demineralizingefficacy of EDTA on dentin was shown by Valdrighi tobe between 5.0 and 6.0.276

Goldberg and Abramovich have shown that EDTACincreases permeability into dentinal tubules, accessorycanals, and apical foramina277 (Figure 10-42).McComb and Smith found that EDTA (in its commer-

Figure 10-41 A, Canal wall untreated by acid. Note granular material and obstructed tubuli. B, Midroot canal wall treated with citric acid.The surface is generally free of debris. C, Midroot canal wall cleaned with phosphoric acid, showing an exceptionally clean regular surface.D, Apical area of root canal etched by phosphoric acid, revealing lateral canals. Reproduced with permission from Tidmarsh BG.268

B

DC

A

Page 101: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 505

cial form, REDTA), when sealed in the canal for 24hours, produced the cleanest dentinal walls.278

Goldman and colleagues have shown that the smearlayer is not removed by sodium hypochlorite irrigationalone but is removed with the combined use ofREDTA.279 This study helps answer the question of thecomposition of the smear layer since chelating agents

remove only calcified tissue, whereas sodiumhypochlorite removes organic material. Goldberg andSpielberg have shown that the optimal working time ofEDTA is 15 minutes, after which time no more chelat-ing action can be expected.280 This study indicates thatEDTA solutions should perhaps be renewed in thecanal each 15 minutes.

Since Goldman et al.’s landmark research in 1981,reporting the efficacy of EDTA and sodium hypochlo-rite to remove the smear layer, a host of confirmingreports have been published.281–289 The US ArmyInstitute of Dental Research, after first reporting theconstituents, the thickness, and the layering of thesmear layer,281 followed up with two reports detailingthe importance of alternate use of 15% EDTA and5.25% sodium hypochlorite.282–287 They introduced atotal of 33 mL of irrigants into each canal, using 27 gblunt Monoject endodontic needles. The originalNygaard-Østby formula for 15% EDTA was used: di-sodium salt of EDTA, 17 g; distilled water, 100 mL; and5 N sodium hydroxide, 9.25 mL.287

Developed by Stewart and others in 1969,290

RC-Prep is composed of EDTA and urea peroxide in abase of Carbowax. It is not water soluble. Its populari-ty, in combination with sodium hypochlorite, isenhanced by the interaction of the urea peroxide inRC-Prep with sodium hypochlorite, producing a bub-bling action thought to loosen and help float out denti-nal debris.291

Zubriggen et al., however, reported that a residue ofRC-Prep remains in the canals in spite of further irri-gation and cleansing.292 This led to the question ofthe effect of RC-Prep residue on apical seal. Cooke etal. showed that RC-Prep allowed maximum leakageinto filled canals—over 2.6 times the leakage of thecontrols.293

EXPLORATION FOR THE CANAL ORIFICE

Before the canals can be entered, their orifices must befound. In older patients, finding a canal orifice may bethe most difficult and time-consuming operation.

Obviously, a knowledge of pulp anatomy (knowingwhere to look and expect to find the orifices) is of firstimportance. Perseverance is the second requirement, fol-lowed by a calm resolve not to become desperate and dec-imate the internal tooth when the orifice does not appear.

The endodontic explorer is the greatest aid in find-ing a minute canal entrance (Figure 10-43), feelingalong the walls and into the floor of the chamber in thearea where the orifices are expected to be. Extension ofthe walls toward these points forms the basic perimeterof the preparation.

Figure 10-42 A, Coronal portion of canal of in vivo endodonticallytreated tooth with EDTAC. The tubules are open, and the canal isclean and free of smear. B, Filed canal treated with EDTAC.Longitudinal section of dentinal tubules shows thin intertubularmatrix. A reproduced with permission from Kaufman AY et al.239 Breproduced with permission from Goldberg F and Abramovich A.277

A

B

Page 102: Ch10: ENDODONTIC CAVITY PREPARATION

A new addition to finding and enlarging canal ori-fices is the Micro-Opener (Dentsply/Maillefer; Tulsa,Okla.) (Figure 10-44, A), with K-type flutes in 0.04 and0.06 tapers, mounted like a spreader, that can be usedto uncover, enlarge, and flare orifices. This can be fol-lowed by the Micro-Debrider in ISO 0.02 taper,

506 Endodontics

Hedstroem-type flutes (Figure 10-44, B) to further flaredown the canal.

The radiograph is invaluable in determining justwhere and in which direction canals enter into the pulpchamber. This is especially true in the maxillary molars.The initial radiograph is one of the most importantaids available to the clinician but, unfortunately, one ofthe least used during cavity preparation. A bite-wingradiograph is particularly helpful in providing anundistorted view of the pulp chamber. The handpieceand bur may be held up to the radiograph to estimatethe correct depth of penetration and direction to theorifices (Figure 10-45).

Color is another invaluable aid in finding a canalorifice. The floor of the pulp chamber and the contin-uous anatomic line that connects the orifices (theso-called molar triangle) are dark (Figure 10-46, A)—dark gray or sometimes brown in contrast to the whiteor light yellow of the walls of the chamber (Figure 10-46, B). Using a No. 1 or 2 bur and “following out” thecolored pathway from one orifice often leads to the elu-sive second, third, or even fourth orifice.

Canal orifices are often so restrictive that they needto be flared so that instruments may enter easily.Orifice openers, from hand-operated Micro-Openersto contra-angle powered reamers with a greater taper(.0.04, 0.06), and Gates-Glidden drills are de rigueur.

More recent is the development of endodontic ultra-sonic units for surgical procedures, that has resulted inattachments for use in the pulp chamber, orifice, andcanal. One of these attachments is a “cutting explorer.”These tips allow the clinician not only to pick at the ori-fice but also to cut into the orifice without removingexcessive amounts of dentin. Using magnification(loupes, Orascope [Spectrum Dental, Inc. North

Figure 10-43 Opposite ends of an endodontic DG explorer. A,Right angle. B, Binangle. (Courtesy of Interdent, Inc., Culver City,Calif.)

Figure 10-44 A, The Micro-Opener with K-styleflutes and 0.04 and 0.06 flare is used to enlarge theorifice of the canal so that B, the Micro-Debrider,with Hedstroem-type flutes and an .02 flare, can beused to further open and widen the canal orifice.(Courtesy of Dentsply/Maillefer.)A

B

A B

Page 103: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 507

Attlebora, Mass.], or a microscope) can also be atremendous help in finding and negotiating these canals.

Sometimes a greatly receded pulp has to be followedwell down into the root to find the orifice to theremaining canal. Measurements on the radiographindicate how many millimeters to drill before the ori-fice is encountered. The use of surgical-length burs,even in a miniature handpiece, will extend the depth ofcut to well beyond 15 mm.

It is most important to enlarge the occlusal openingso complete authority over the direction of the instru-ment can be maintained (Figure 10-47). Repeated radi-ographs to verify the depth and direction of the cut arealso invaluable.

Axioms of Pulp Anatomy

Remembering the following axioms of pulp anatomycan be most helpful:

1. The two orifices of the maxillary first premolar arefurther to the buccal and the lingual than is usuallysuspected (Plate 13).

2. The orifices of the mesiobuccal canals in both themaxillary and mandibular molars are well up underthe mesiobuccal cusp, and the outline form must oftenbe widely extended into the cusp (Plates 21 and 22).

3. The orifice to the lingual canal in the maxillarymolars is not far to the lingual but is actually in thecenter of the mesial half of the tooth (Plates 21 and22, 24 and 25).

4. The orifice to the distobuccal canal of the maxillarymolars is not far to the distobuccal but is actually

almost directly buccal from the lingual orifice(Plates 21 and 22).

5. The orifice to the distal canal in mandibular molarsis not far to the distal but is actually in almost theexact center of the tooth (Plates 25 and 26).

6. The orifice to the mesiolingual canal of themandibular molars is not far to the mesiolingualbut is actually almost directly mesial from the distalorifice (Plates 25 and 26).

7. Certain anatomic variations occur with enough fre-quency to warrant mention here:a. The mesiobuccal root of the maxillary first

molar may often have an extra mesiolingualcanal just lingual to the mesiobuccal orifice(Figure 10-48). It is found in the groove thatcomes off the mesiobuccal orifice like the tailon a comma. This entire groove should beexplored for the mesiolingual canal; 62% of thetime, the two mesial canals exit through twoseparate foramina.28

b. Mandibular second molars frequently have acommon mesial orifice that divides about 1 mm

Figure 10-45 Bur held alongside radiograph to estimate the depthof penetration. (Courtesy of Dr. Thomas P. Mullaney.)

Figure 10-46 A, The dark line of the molar triangle is obvious inthis cross-section of a mandibular second molar. B, The dark colorof the floor of the pulp chamber contrasts markedly with the lightcolor (arrow) of the side walls of preparation.

Page 104: Ch10: ENDODONTIC CAVITY PREPARATION

below the floor of the pulp chamber into amesiobuccal and a mesiolingual canal.

c. Mandibular first and second molars may havetwo distal canals, with either separate orifices, ora common orifice as described for the mesial.

d. Mandibular first premolars frequently have asecond canal branching off the main canal to thebuccal or lingual, several millimeters below thepulp chamber floor.

508 Endodontics

e. Mandibular incisors frequently have two canals.The lingual canal is hidden beneath the internal“shoulder” that corresponds to the lingual cin-gulum. This “shoulder” prominence must beremoved with a No. 2 long-shank round bur ora fine tapered diamond “stone” to permit prop-er exploration.

In summary, the unexpected should always beanticipated, and the operator must be prepared toexpand the access cavity for convenience in enlargingone of these canals or even just to increase visual exam-ination of the pulp chamber floor in searching for suchanatomic variance.

EXPLORATION OF THE CANAL

Besides the use of radiographs, the use of a fine curvedreamer or file is a method available to determine cur-vature in canals. Stainless steel instruments are bettersuited for this purpose. The superelastic properties ofnickel titanium, which make them desirous during thecleaning and shaping phase, are not helpful in thesmaller sizes (6, 8, 10) when used for pathfinding.Many times, however, it cannot be determined that thecanal is curved until enlargement begins and resistancedevelops to instrument placement above the No. 25 orNo. 30 file owing to a lack of file flexibility. This will bediscussed later in the chapter.

Figure 10-47 “Step-down” preparation. Necessity of maintaining control over burs and endodontic instruments in following out advancedpulpal recession. A, Coronal cavity is enlarged sufficiently to accommodate the shaft of a No. 4 surgical-length bur that must function with-out touching the cavity walls. B, Freely operating the No. 4 surgical-length bur following out receded pulp. C, A No. 2 surgical-length burused in depths of preparation. Repeated radiographs may be necessary to judge the progress of the instrument. D, Fine root canal instru-ment used to explore and finally enlarge the patent portion of the canal.

Figure 10-48 Two canals in the mesial root are clearly discernibleby radiograph (arrows). Both canals apparently have separate api-cal foramina. (Courtesy of Dr. James D. Zidell.)

Page 105: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 509

A curved pathfinder file should be used to explorethe walls and direction of the canal. The argumentagainst using a straight instrument is that it may tendto engage the wall at the curve or pivot on a catch onthe walls (Figure 10-49). The curved tip of the instru-ment will scribe a circle when the instrument is turnedon its axis, whereas the perfectly straight instrumentwill rotate only on the central axis of the instrument(Figure 10-50).

A curved pathfinding instrument can be rotatedaway from a catch or curve on the wall and advanceddown the canal to the apical region (see Figure 10-49).From the initial pathfinding instrument, the length ofthe tooth may be established. With control of probing,poking, twisting, and turning, the fine pathfinder canalmost always be penetrated to working length. Theaction can best be described as a “watch-winding” typeof finger action.

If unable to reach the apex with reasonable effort,however, the clinician should increase the taper of thecoronal part of the canal. Nickel-titanium files, withtapers greater than the standard ISO 0.02 mm/mm,have proved to make this process safe and more effi-cient. Once this has been achieved, it becomes possibleto advance the pathfinder to working length.

When tentative working length is reached with acurved pathfinder file, the operator can determine thedirection of curvature by noting the direction of the tipof the file when it is withdrawn. This is a valuable cluefor now the clinician knows the direction in which thecanal curves and may guide the instrument accordingly.Valuable time is saved by eliminating exploration eachtime the instrument is placed in the canal. If ateardrop-shaped silicone stop is placed on the files, thepointed end indicates the direction of the file curvature.

One method to curve an instrument is to insert thetip into the end of a sterile cotton roll or gauze spongeand bend the instrument under the pressure of thethumbnail (Figure 10-51). Cotton pliers used to makethis bend damage the flutes of fine instruments. TheBuchanan Endo-Bender is better for this task (SybronEndo/Analytic; Orange, Calif.)90,91

In exploring a canal with a curved instrument, theclinician should always expect the worst. One shouldprobe with the point toward the buccal and lingual, thatis, toward the direction of the x-ray beam, alwayssearching for the unusual curvature that does not showon the radiograph. As mentioned previously, the palatalcanals of maxillary molars, and the maxillary lateral

Figure 10-49 A, When a straight instrument catches on a canalobstruction, turning the instrument merely drives the point deeperinto the obstruction. B and C, When a curved instrument catches onan obstruction, the rotating point of the instrument detaches it fromthe obstruction so that the instrument may be moved up the canal.

Figure 10-50 When turned on its axis, the tip of a curved instru-ment (left) scribes a circle. The tip of a straight instrument (right)turns on its own axis, which reduces control of the tip of theinstrument.

Page 106: Ch10: ENDODONTIC CAVITY PREPARATION

incisors and canines, are always suspect. In mandibularpremolars, curvature of the canal toward the buccal orlingual is a common occurrence as well (Figure 10-52).In these teeth, particularly the mandibular first premo-lar, anomalies of the canals frequently exist: doublecanals, bifurcated canals, and apical deltas are common.This also applies to the mandibular anterior teeth,

510 Endodontics

where a search with the curved pathfinder shouldalways be made for two canals, toward the labial and thelingual (Plates 9, F and 11, D).

Extra canals, such as three canals in the maxillaryfirst premolar, two canals in the maxillary second pre-molar, or two canals in the mesiobuccal root of themaxillary first molar, should also be searched for(Plates 13, 14, 21). The fourth canal toward the distal ina mandibular molar is occasionally found by carefulexploration, first with the endodontic explorer andthen with the curved instrument. Finding the extra orunusual canal spells the difference between success andfailure.

DETERMINATION OF WORKING LENGTH

The determination of an accurate working length isone of the most critical steps of endodontic therapy.The cleaning, shaping, and obturation of the root canalsystem cannot be accomplished accurately unless theworking length is determined precisely.294–296

Anatomic Considerations and Terminology

Simon has stressed the need for clarification and consis-tency in the use of terms related to working length deter-mination.297 Working length (Figure 10-53) is defined in

Figure 10-51 Curving point of an instrument. The tip is intro-duced into the end of a sterile cotton roll and is bent under athumbnail padded by cotton.

Figure 10-52 A, Working length film, mandibular premolar. The patient experienced sensitivity even though the instrument appearsapproximately 3 mm short of the radiographic apex. B, Preoperative mesio-angled radiograph of the same tooth showing canal curvatureand the labial exit of the foramen (arrow) not evident on the working length film. (Courtesy of Dr. Thomas P. Mullaney.)

Page 107: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 511

the endodontic Glossary as “the distance from a coronalreference point to the point at which canal preparationand obturation should terminate,”298 the ideal apical ref-erence point in the canal, the “apical stop,” so to speak.

The anatomic apex is the tip or the end of the rootdetermined morphologically, whereas the radiographicapex is the tip or end of the root determined radi-ographically.298 Root morphology and radiographicdistortion may cause the location of the radiographicapex to vary from the anatomic apex.

The apical foramen is the main apical opening of theroot canal. It is frequently eccentrically located awayfrom the anatomic or radiographic apex.299–301 Kuttler’sinvestigation showed that this deviation occurred in 68to 80% of teeth in his study.301 An accessory foramen isan orifice on the surface of the root communicatingwith a lateral or accessory canal.298 They may exist as asingle foramen or as multiple foramina.

The apical constriction (minor apical diameter)(Figure 10-54) is the apical portion of the root canalhaving the narrowest diameter. This position may varybut is usually 0.5 to 1.0 mm short of the center of theapical foramen.298–300 The minor diameter widens api-cally to the foramen (major diameter) and assumes afunnel shape.

The apical third is the most studied region of theroot canal.299,300,302–307 Dummer and his coworkersreported many variations in the apical constriction.300

In 6% of cases, the constriction may be blocked bycementum.300

The cementodentinal junction is the region where thedentin and cementum are united, the point at which thecemental surface terminates at or near the apex of atooth.298 It must be pointed out, however, that thecementodentinal junction is a histologic landmark thatcannot be located clinically or radiographically.Langeland reported that the cementodentinal junctiondoes not always coincide with the apical constriction.308

The location of the cementinodentinal junction alsoranges from 0.5 to 3.0 mm short of the anatomicapex.298–305,309–313 Therefore, it is generally acceptedthat the apical constriction is most frequently located

Figure 10-53 Care should be exercised to establish the position ofthe foramen. Hopefully, it appears at the apex, and 0.5 to 1.0 mm issimply subtracted from that tooth length as a safety factor. The lat-eral exit of the canal (right) can sometimes be seen in radiographor discovered by instrument placement and re-examined radi-ographically. Even the patient’s reaction to the instrument is awarning of “early exit,” especially toward the labial or lingualunseen in the radiograph. Reproduced with permission fromSerene T, Krasny R, Ziegler P, et al. Principles of preclinicalendodontics. Dubuque (IA): Kendall/Hunt Publishing; 1974.

Figure 10-54 Diagrammatic view of theperiapex. The importance of differentiat-ing between the minor diameter (apicalstop) and the major diameter (radi-ographic apex) is apparent. (Courtesy ofDr. Stephen Weeks.)

Page 108: Ch10: ENDODONTIC CAVITY PREPARATION

0.5 to 1.0 mm short of the radiographic apex, but withvariations. Problems exist in locating apical landmarksand in interpreting their positions on radiographs.

Clinical Considerations

Before determining a definitive working length, the coro-nal access to the pulp chamber must provide a straight-line pathway into the canal orifice. Modifications inaccess preparation may be required to permit the instru-ment to penetrate, unimpeded, to the apical constriction.As stated above, a small stainless steel K file facilitates theprocess and the exploration of the canal.

Loss of working length during cleaning and shapingcan be a frustrating procedural error. Once the apicalrestriction is established, it is extremely important tomonitor the working length periodically since theworking length may change as a curved canal isstraightened (“a straight line is the shortest distancebetween two points”).314,315 The loss may also be relat-ed to the accumulation of dentinal and pulpal debris inthe apical 2 to 3 mm of the canal or other factors suchas failing to maintain foramen patency,316 skippinginstrument sizes, or failing to irrigate the apical one-third adequately. Occasionally, working length is lostowing to ledge formation or to instrument separationand blockage of the canal.

Two in vivo studies measured the effect of canalpreparation on working length.314–316 The mean short-ening of all canals in these studies was found to rangefrom 0.40 mm to 0.63 mm.

There has been debate as to the optimal length ofcanal preparation and the optimal level of canal obtu-ration.317 Most dentists agree that the desired endpoint is the apical constriction, which is not only thenarrowest part of the canal318 but a morphologic land-mark299,302 that can help to improve the apical sealwhen the canal is obturated.319–321

Failure to accurately determine and maintain work-ing length may result in the length being too long andmay lead to perforation through the apical constric-tion. Destruction of the constriction may lead to over-filling or overextension and an increased incidence ofpostoperative pain. In addition, one might expect aprolonged healing period and lower success rate owingto incomplete regeneration of cementum, periodontalligament, and alveolar bone.322–325

Failure to determine and maintain working lengthaccurately may also lead to shaping and cleaning shortof the apical constriction. Incomplete cleaning andunderfilling may cause persistent discomfort, oftenassociated with an incomplete apical seal. Also, apicalleakage may occur into the uncleaned and unfilled

512 Endodontics

space short of the apical constriction. Such leakagesupports the continued existence of viable bacteria andcontributes to a continued periradicular lesion andlowered rate of success.

In this era of improved illumination and magnifica-tion, working length determination should be to thenearest one-half millimeter. The measurement should bemade from a secure reference point on the crown, in closeproximity to the straight-line path of the instrument, apoint that can be identified and monitored accurately.

Stop Attachments. A variety of stop attachmentsare available. Among the least expensive and simplestto use are silicone rubber stops. Several brands ofinstruments are now supplied with the stop attach-ments already in place on the shaft. Special tear-shapedor marked rubber stops can be positioned to align withthe direction of the curve placed in a precurved stain-less steel instrument.

The length adjustment of the stop attachmentsshould be made against the edge of a sterile metric ruleror a gauge made specifically for endodontics. Deviceshave been developed that assist in adjusting rubberstops on instruments326 (Figure 10-55). It is critical thatthe stop attachment be perpendicular and not obliqueto the shaft of the instrument (Figure 10-56).

There are several disadvantages to using rubberstops. Not only is it time consuming, but rubber stopsmay move up or down the shaft, which may lead topreparations short or past the apical constriction.

The clinician should develop a mental image of theposition of the rubber stop on the instrument shaft inrelation to the base of the handle. Any movement fromthat position should be immediately detected and cor-rected. One should also develop a habit of lookingdirectly at the rubber stop where it meets the reference

Figure 10-55 Guldener Endo-M-Bloc has 32 depth guides in tworows. Front row indicators from 10 to 30 mm in 1 mm increments.Back row indicators are 0.5 mm deeper. Helpful ruler at end. Thedevice is invaluable in step-back or step-down techniques.(Courtesy of Dentsply/Maillefer).

Page 109: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 513

point on the tooth. It is also essential to record the ref-erence point and the working length of each instru-ment in the patient’s chart.

Instruments have been developed with millimetermarking rings etched or grooved into the shaft of theinstrument. These act as a built-in ruler with the mark-ings placed at 18, 19, 20, 22, and 24 mm. With thesemarking rings, the best coronal reference point on thetooth is at the cavo-incisal or cavo-occlusal angle.These marking rings are necessary when rotary nickel-titanium instruments are used.

METHODS OF DETERMINING WORKING LENGTH

Ideal Method

The requirements of an ideal method for determiningworking length might include rapid location of the api-cal constriction in all pulpal conditions and all canalcontents; easy measurement, even when the relationshipbetween the apical constriction and the radiographicapex is unusual; rapid periodic monitoring and confir-mation; patient and clinician comfort; minimal radia-tion to the patient; ease of use in special patients such asthose with severe gag reflex, reduced mouth opening,pregnancy etc; and cost effectiveness.327,328

To achieve the highest degree of accuracy in workinglength determination, a combination of several meth-ods should be used. This is most important in canals

for which working length determination is difficult.The most common methods are radiographic meth-ods, digital tactile sense, and electronic methods. Apicalperiodontal sensitivity and paper point measurementshave also been used.

Determination of Working Length by Radiographic Methods

Methods requiring formulas to determine workinglength have been abandoned. Bramante and Berbertreported great variability in formulaic determinationof working length, with only a small percentage of suc-cessful measurements.295

The radiographic method known as the IngleMethod329 has been compared with three other meth-ods of determining working length.295 The IngleMethod proved to be “superior to others” in the study.It showed a high percentage of success with a smallervariability. This method, first proposed more than 40years ago, has withstood the test of time and hasbecome the standard as the most commonly usedmethod of radiographic working length estimation.

Radiographic Apex Location. Materials andConditions. The following items are essential to per-form this procedure:

1. Good, undistorted, preoperative radiographs show-ing the total length and all roots of the involvedtooth.

2. Adequate coronal access to all canals.3. An endodontic millimeter ruler.4. Working knowledge of the average length of all of

the teeth.5. A definite, repeatable plane of reference to an

anatomic landmark on the tooth, a fact that shouldbe noted on the patient’s record.

It is imperative that teeth with fractured cusps orcusps severely weakened by caries or restoration bereduced to a flattened surface, supported by dentin.Failure to do so may result in cusps or weak enamelwalls being fractured between appointments (Figure10-57). Thus, the original site of reference is lost. If thisfracture goes unobserved, there is the probability ofoverinstrumentation and overfilling, particularly whenanesthesia is used.

To establish the length of the tooth, a stainless steelreamer or file with an instrument stop on the shaft isneeded. The exploring instrument size must be smallenough to negotiate the total length of the canal butlarge enough not to be loose in the canal. A loose instru-ment may move in or out of the canal after the radi-

Figure 10-56 Left, Stop attachment should be placed perpendicu-lar to the long axis of the instrument. Right, Obliquely placed stopattachment varies the length of tooth measurement by over 1 mm.

Page 110: Ch10: ENDODONTIC CAVITY PREPARATION

ograph and cause serious error in determining thelength of tooth. Moreover, fine instruments (Nos. 08 and10) are often difficult to see in their entirety in a radi-ograph,330 as are nickel-titanium instruments. Onceagain, in a curved canal, a curved instrument is essential.

Method

1. Measure the tooth on the preoperative radiograph(Figure 10-58, A).

2. Subtract at least 1.0 mm “safety allowance” for pos-sible image distortion or magnification.331

3. Set the endodontic ruler at this tentative workinglength and adjust the stop on the instrument at thatlevel (Figure 10-58, B).

4. Place the instrument in the canal until the stop is atthe plane of reference unless pain is felt (if anesthe-sia has not been used), in which case, the instru-

514 Endodontics

ment is left at that level and the rubber stop read-justed to this new point of reference.

5. Expose, develop, and clear the radiograph.6. On the radiograph, measure the difference between

the end of the instrument and the end of the rootand add this amount to the original measuredlength the instrument extended into the tooth(Figure 10-58, C). If, through some oversight, theexploring instrument has gone beyond the apex,subtract this difference.

7. From this adjusted length of tooth, subtract a 1.0mm “safety factor” to conform with the apical ter-mination of the root canal at the apical constriction(see Figure 10-58, C).332

Weine has made a sensible improvement in thisdetermination: If, radiographically, there is no resorp-tion of the root end or bone, shorten the length by thestandard 1.0 mm.332 If periapical bone resorption isapparent, shorten by 1.5 mm, and if both root andbone resorption are apparent, shorten by 2.0 mm(Figure 10-59). The reasoning behind this suggestionis thoughtful. If there is root resorption, the apicalconstriction is probably destroyed—hence the shortermove back up the canal. Also, when bone resorption isapparent, there probably is also root resorption, eventhough it may not be apparent radiographically.

8. Set the endodontic ruler at this new correctedlength and readjust the stop on the exploringinstrument (Figure 10-58, D).

9. Because of the possibility of radiographic distor-tion, sharply curving roots, and operator measuringerror, a confirmatory radiograph of the adjustedlength is highly desirable. In many instances, anadded investment of a few minutes will prevent thediscomfort and failure that stem from inaccuracy.

10. When the length of the tooth has been accuratelyconfirmed, reset the endodontic ruler at this meas-urement.

11. Record this final working length and the coronalpoint of reference on the patient’s record.

12. Once again, it is important to emphasize that thefinal working length may shorten by as much as 1 mm as a curved canal is straightened out byinstrumentation.314,315 It is therefore recommend-ed that the “length of the tooth” in a curved canal bereconfirmed after instrumentation is completed.

Variations. When the two canals of a maxillaryfirst premolar appear to be superimposed, much con-fusion and lost time may be saved by several simplemeans. Occasionally, it is advantageous to take individ-ual radiographs of each canal with its length-of-tooth

Figure 10-57 A, Do not use weakened enamel walls or diagonallines of fracture as a reference site for length-of-tooth measure-ment. B, Weakened cusps or incisal edges are reduced to a well-sup-ported tooth structure. Diagonal surfaces should be flattened togive an accurate site of reference.

Page 111: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 515

Figure 10-58 A, Initial measurement. The tooth is measured on a good preoperative radiograph using the long cone technique. In this case,the tooth appears to be 23 mm long on the radiograph. B, Tentative working length. As a safety factor, allowing for image distortion or mag-nification, subtract at least 1 mm from the initial measurement for a tentative working length of 22 mm. The instrument is set with a stop atthis length. C, Final working length. The instrument is inserted into the tooth to this length and a radiograph is taken. Radiograph showsthat the image of the instrument appears to be 1.5 mm from the radiographic end of the root. This is added to the tentative working length,giving a total length of 23.5 mm. From this, subtract 1.0 mm as adjustment for apical termination short of the cementodentinal junction (seeAnatomic Considerations). The final working length is 22.5 mm. D, Setting instruments. The final working length of 22.5 mm is used to setstops on instruments used to enlarge the root canal.

Figure 10-59 Weine’s recommendations for determining working length based on radiographic evidence of root/bone resorption. A, If noroot or bone resorption is evident, preparation should terminate 1.0 mm from the apical foramen. B, If bone resorption is apparent but thereis no root resorption, shorten the length by 1.5 mm. C, If both root and bone resorption are apparent, shorten the length by 2.0 mm.(Courtesy of Dr. Franklin Weine.)

Page 112: Ch10: ENDODONTIC CAVITY PREPARATION

instrument in place. A preferable method is to exposethe radiograph from a mesial-horizontal angle. Thiscauses the lingual canal to always be the more mesialone in the image (MLM, Clark’s rule) or, alternatively,MBD—when the x-ray beam is directed from theMesial, the Buccal canal is projected toward the Distalon the film.

When a mandibular molar appears to have twomesial roots or apices of different lengths or positions,two mesial instruments can be used, and again thetooth can be examined radiographically from themesial and Clark’s or Ingle’s rule (MLM or MBD)applied.

Accuracy. Just how accurate is this radiographicmeasurement method? For one thing, accuracydepends on the radiographic technique used. Forsberg,in Norway, demonstrated that paralleling techniquewas “significantly more reliable” than thebisecting-angle technique.333 A US Army group, how-ever, found that the paralleling technique was absolute-ly accurate only 82% of the time.334 Von der Lehr andMarsh were accurate in anterior teeth 89% of thetime.335 Paralleling still magnifies actual tooth lengthby 5.4%.331

As Olson et al. pointed out, 82 to 89% accuracy isnot 100%, so they recommended back-up methodssuch as tactile feel, moisture on the tip of a paper point,or electronic apex locators.334 Similar results and rec-ommendations have been reported worldwide.336–341 ABritish group, for example, recommended the use ofradiovisiography with image enhancement to improvethe quality of length-of-tooth radiographs.341

Accuracy of Working Length Estimation by DirectDigital Radiography or Xeroradiography

Several studies have evaluated the advantages of usingdirect digital radiography or xeroradiography for theestimation of working length.342–355

The results of the studies indicate that there is nostatistically significant difference in working lengthestimation accuracy between conventional film, directdigital radiography, and xeroradiography. On the otherhand, rapid imaging and reduction in radiation bythese techniques represent a significant advancementin dental radiography (see Chapter 9).

Determination of Working Length by Digital Tactile Sense

If the coronal portion of the canal is not constrict-ed, an experienced clinician may detect an increase inresistance as the file approaches the apical 2 to 3 mm.This detection is by tactile sense. In this region, the

516 Endodontics

canal frequently constricts (minor diameter) beforeexiting the root. There is also a tendency for the canalto deviate from the radiographic apex in thisregion.299,301,302,339,356

Seidberg et al. reported an accuracy of just 64%using digital tactile sense.296 Another in vivo studyfound that the exact position of the apical constrictioncould be located accurately by tactile sense in only 25%of canals in their study.357

If the canals were preflared, it was possible for anexpert to detect the apical constriction in about 75% ofthe cases.358 If the canals were not preflared, determi-nation of the apical constriction by tactile sensationwas possible in only about one-third of the cases.359

All clinicians should be aware that this method, byitself, is often inexact. It is ineffective in root canalswith an immature apex and is highly inaccurate if thecanal is constricted throughout its entire length or ifthe canal has excessive curvature. This method shouldbe considered as supplementary to high-quality, care-fully aligned, parallel, working length radiographsand/or an apex locator.

A survey found that few general practice dentistsand no endodontists trust the digital tactile sensemethod of determining working length by itself.360

Even the most experienced specialist would be prudentto use two or more methods to determine accurateworking lengths in every canal.

Determination of Working Length by ApicalPeriodontal Sensitivity

Any method of working length determination, basedon the patient’s response to pain, does not meet theideal method of determining working length. Workinglength determination should be painless. Endodontictherapy has gained a notorious reputation for beingpainful, and it is incumbent on dentists to avoid per-petuating the fear of endodontics by inserting anendodontic instrument and using the patient’s painreaction to determine working length.

If an instrument is advanced in the canal towardinflamed tissue, the hydrostatic pressure developedinside the canal may cause moderate to severe, instan-taneous pain. At the onset of the pain, the instrumenttip may still be several millimeters short of the apicalconstriction. When pain is inflicted in this manner, lit-tle useful information is gained by the clinician, andconsiderable damage is done to the patient’s trust.

When the canal contents are totally necrotic, howev-er, the passage of an instrument into the canal and pastthe apical constriction may evoke only a mild awarenessor possibly no reaction at all. The latter is common

Page 113: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 517

when a periradicular lesion is present because the tissueis not richly innervated. On the other hand, Langelandand associates reported that vital pulp tissue with nervesand vessels may remain in the most apical part of themain canal even in the presence of a large periapicallesion.361–363 This suggests that a painful response maybe obtained inside the canal even though the canal con-tents are “necrotic” and there is a periapical lesion.

It would appear that any response from the patient,even an eye squint or wrinkling of the forehead, callsfor reconfirmation of working length by other methodsavailable and/or profound supplementary anesthesia.

Determination of Working Length by Paper Point Measurement

In a root canal with an immature (wide open) apex, themost reliable means of determining working length isto gently pass the blunt end of a paper point into thecanal after profound anesthesia has been achieved. Themoisture or blood on the portion of the paper pointthat passes beyond the apex may be an estimation ofworking length or the junction between the root apexand the bone. In cases in which the apical constrictionhas been lost owing to resorption or perforation, and inwhich there is no free bleeding or suppuration into thecanal, the moisture or blood on the paper point is anestimate of the amount the preparation is overextend-ed. This paper point measurement method is a supple-mentary one.

A new dimension has recently been added to paperpoints by the addition of millimeter markings (Figure10-60). These paper points have markings at 18, 19, 20,22, and 24 mm from the tip and can be used to estimatethe point at which the paper point passes out of theapex. These paper points were designed to ensure thatthey be inserted fully to the apical constriction. Theaccuracy of these markings should be checked on amillimeter ruler.

Determination of Working Length by Electronics

Evolution of Apex Locators. Although the term“apex locator” is commonly used and has becomeaccepted terminology,298 it is a misnomer.364 Someauthors have used other terms to be more pre-cise.365–372 These devices all attempt to locate the apicalconstriction, the cementodentinal junction, or the api-cal foramen. They are not capable of routinely locatingthe radiographic apex. In 1918, Custer was the first toreport the use of electric current to determine workinglength.373 The scientific basis for apex locators origi-nated with research conducted by Suzuki in 1942.374

His in vivo research on dogs using direct current dis-covered that the electrical resistance between the peri-odontal ligament and the oral mucosa was a constantvalue of 6.5 kilo-ohms. In 1960, Gordon was the secondto report the use of a clinical device for electrical meas-urement of root canals.375 Sunada adopted the princi-ple reported by Suzuki and was the first to describe thedetail of a simple clinical device to measure workinglength in patients.376 He used a simple direct currentohmmeter to measure a constant resistance of 6.5 kilo-ohms between oral mucous membrane and the peri-odontum regardless of the size or shape of the teeth.The device used by Sunada in his research became thebasis for most apex locators.

Inoue made significant contributions to the evolu-tion of apex locators in North America with his reportson the Sono-Explorer.294,377–380 In recent years, severaladvancements and modification in the electronicdesign of apex locators have been reported.381–388

All apex locators function by using the human bodyto complete an electrical circuit. One side of the apexlocator’s circuitry is connected to an endodontic instru-ment. The other side is connected to the patient’s body,either by a contact to the patient’s lip or by an electrodeheld in the patient’s hand. The electrical circuit is com-plete when the endodontic instrument is advanced api-cally inside the root canal until it touches periodontaltissue (Figure 10-61). The display on the apex locatorindicates that the apical area has been reached.

This simple and commonly accepted explanation forthe electronic phenomenon has been challenged.382,383,389

Figure 10-60 Absorbent paper points, sterilized, color coded, andmarked with millimeter markings. (Courtesy of Diadent Group,Burnaby, BC, Canada)

Page 114: Ch10: ENDODONTIC CAVITY PREPARATION

There is evidence that electronic devices measure mainlythe impedance of the probing electrode (contact imped-ance with the tissue fluid) rather than tissue impedanceitself. Huang reported that the principle of electronic rootcanal measurement can be explained by physical princi-ples of electricity alone.389 Ushiyama and colleagues pre-sented this as the “voltage gradient method” that couldaccurately measure working length in root canals filledwith electrolyte.381–383 A major disadvantage with thismethod was that it used a special bipolar electrode thatwas too large to pass into narrow root canals.

Experimental Design and Parameters of AccuracyStudies. In vitro accuracy studies may be conductedon models using an extracted tooth in an electrolyte tosimulate clinical conditions.366,368–370,390–394 The idealconditions in in vitro testing may give accuracy resultshigher than those obtainable in clinical practice.Alternatively, in the fabrication of the in vitro model,electrolyte may be inadvertently forced into the canalspace and give rise to an inaccuracy.

In vivo accuracy studies more closely reflect the real-ity of conditions in clinical practice. The best studiesare those that use an apex locator to determine theworking length of a canal followed by “locking” themeasuring instrument at the electronic length. Thetooth is extracted, and the exact relationship betweenthe electronic length and the apical constriction isdetermined. Unfortunately, this design is not a viablealternative in most studies. Even when the design is

518 Endodontics

used, the studies might be improved by prior shapingand cleaning of the canal followed by multiple elec-tronic working length determinations.

In in vivo comparative studies in which the electron-ic file tip to apical constriction is also assessed by radi-ographs, the validity of the results is open to question.The comparisons are only as accurate as the accuracy ofthe radiographic method of estimating working length.Current information places this accuracy in the 39 to86% range.301,340,356,365,395–398

Using cadavers, Pratten and McDonald comparedthe accuracy of three parallel radiographs of each canalat three horizontal angles with the accuracy of theEndex apex locator.399 Even in these ideal conditions,radiographic estimation was no more accurate thanelectronic determination.

Another important point in accuracy studies is theerror tolerance that is accepted in the experimentaldesign. There appears to be a growing concern that eithera +0.5 error or a –0.5 error may give rise to clinical prob-lems and that the ±0.5 tolerance may be unacceptable.400

It would be useful clinically to use the apical con-striction as the ideal apical reference point in the canalrather than the apical foramen.401,402 Considerationshould also be given to using –0.5 to 0.0 mm as themost clinically ideal error tolerance.

Classification and Accuracy of Apex Locators.The classification of apex locators presented here is amodification of the classification presented by

Figure 10-61 A, Typical circuit for electronic determination of workinglength. Current flows from Electronic apex locator (EAL) to the file, to thecementoenamel junction and back to the EAL, where the position of the tipsis illustrated. The circuit is completed through lip attachment. B, The apicalforamen some distance from the radiographic apex stresses the importanceof finding the actual orifice by EAL. D = dentin; C = cementum. A courtesyof Dr. Stephen Weeks. B reproduced with permission from Skillen WG. J AmDent Assoc 1930;17:2082.

A

B

Page 115: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 519

McDonald.403 This classification is based on the type ofcurrent flow and the opposition to the current flow, aswell as the number of frequencies involved.

First-Generation Apex Locators. First-generationapex location devices, also known as resistance apexlocators,403 measure opposition to the flow of direct cur-rent or resistance. When the tip of the reamer reaches theapex in the canal, the resistance value is 6.5 kilo-ohms(current 40 mA). Although it had some problems, theoriginal device was reported to be most accurate inpalatal canals of maxillary molars and premolars.295

Initially, the Sono-Explorer (Satalec, Inc, Mount Laurel,N.J.) was imported from Japan by Amadent. Today, mostfirst-generation apex location devices are off the market.

Second-Generation Apex Locators. Second-genera-tion apex locators, also known as impedance apex loca-tors,403 measure opposition to the flow of alternatingcurrent or impedance. Inoue developed the Sono-Explorer,377–380 one of the earliest of the second-gener-ation apex locators. Several other second-generationapex locators then became available, including a num-ber of improvements in the Sono-Explorer.

The major disadvantage of second-generation apexlocators is that the root canal has to be reasonably free ofelectroconductive materials to obtain accurate readings.The presence of tissue and electroconductive irrigants inthe canal changes the electrical characteristics and leadsto inaccurate, usually shorter measurements.390 This cre-ated a “catch-22” situation. Should canals be cleaned anddried to measure working length, or should workinglength be measured to clean and dry canals?404

There is another issue: not all apex locators incorpo-rate the same degree of sophistication in electronic cir-cuitry that adjusts its sensitivity to compensate for theintracanal environment405 or indicates on its displaythat it should be switched from a “wet” to a “dry” modeor vice versa. Pilot and Pitts reported that 5.25% sodi-um hypochlorite solution, 14.45% EDTA solution, andnormal saline were conductive, whereas RC Prep andisopropyl alcohol were not.406

The Apex Finder (Sybron Endo/Analytic; Orange,Calif.) has a visual digital LED indicator and is self-cal-ibrating. The Endo Analyzer (Analytic/Endo; Orange,Calif.) is a combined apex locator and pulp tester. TheApex Finder has been subjected to several in vivo stud-ies.365,397,407,408 Compared to radiographic workinglength estimations, one study placed the accuracy at67% (± 0.5 mm from the radiographic apex).365 In astudy in which Apex Finder working length determina-tions were compared with direct anatomic workinglength measurements, only 20% of the determinationswere “coincident,” and 53% were short.397

The Digipex (Mada Equipment Co., Carlstadt, N.J.)has a visual LED digital indicator and an audible indi-cator.404 It requires calibration. The Digipex II is acombination apex locator and pulp vitality tester.

The Exact-A-Pex (Ellman International, Hewlett,N.Y.) has an LED bar graph display and an audio indi-cator.404 An in vivo study reported an accuracy of 55%(± 0.5 mm from the apical foramen).

The Foramatron IV (Parkell Dental, Farmingdale,N.Y.) has a flashing LED light and a digital LED displayand does not require calibration. Two in vivo studieswere reported on the Foramatron IV (Figure 10-62).408,409 Electronic determinations in one study werefound to be accurate (± 0.5 mm from the radiographicapex) in 65% of the cases.408 In the other study, 32% ofthe cases were “coincident” with the radiographic apexand 36% were short.409 None were long. This device issmall, lightweight, and inexpensive.

The Pio (Denterials Ltd., St. Louis, Mo.) apex loca-tor has an analog meter display and an audio indicator.It has an adjusting knob for calibration.

Third-Generation Apex Locators. The principle onwhich “third-generation” apex locators are basedrequires a short introduction. In biologic settings, thereactive component facilitates the flow of alternatingcurrent, more for higher than for lower frequencies.Thus, a tissue through which two alternating currentsof differing frequencies are flowing will impede thelower-frequency current more than the higher-fre-quency current. The reactive component of the circuitmay change, for example, as the position of a filechanges in a canal. When this occurs, the impedancesoffered by the circuit to currents of differing frequen-cies will change relative to each other. This is the prin-ciple on which the operation of the “third-generation”apex locators is based (SM Weeks, personal communi-cation, 1999).

Since the impedance of a given circuit may be sub-stantially influenced by the frequency of the currentflow, these devices have been called “frequencydependent” (SM Weeks, personal communication,1999). Since it is impedance, not frequency, that ismeasured by these devices, and since the relative mag-nitudes of the impedances are converted into “length”information, the term “comparative impedance” maybe more appropriate (SM Weeks, personal communica-tion, 1999).

Endex (Osada Electric Co., Los Angeles, Calif. andJapan), the original third-generation apex locator, wasdescribed by Yamaoka et al.410 (Figure 10-63). InEurope and Asia, this device is available as the APIT. Ituses a very low alternating current.411 The signals of

Page 116: Ch10: ENDODONTIC CAVITY PREPARATION

two frequencies (5 and 1 kHz) are applied as a com-posite waveform of both frequencies. As the attachedendodontic reamer enters the coronal part of the canal,the difference in the impedances at the two frequenciesis small. As the instrument is advanced apically, the dif-

520 Endodontics

ference in impedance values begins to change. As theapical constriction is reached, the impedance values areat their maximum difference, and these differences areindicated on the analog meter and audio alarm. Thisimpedance difference is the basis of the “differencemethod.”380 The unit must then be “reset” (calibrated)for each canal.

The device operates most accurately when the canalis filled with electrolyte (ie, normal saline or sodiumhypochlorite). Gutta-percha must be removed from thecanals in re-treatment cases before electronic workinglength determination is made with this device. Themanufacturer indicates that the size of the endodonticinstrument does not affect the measurement.411

The Endex has been the subject of several accuracystudies.358,364,397,399,412–420 One in vitro study reportedthat the Endex was superior to second-generationdevices when there was conductive fluid in the canalsand when the apical foramen was widened.413 Other invitro studies compared the Endex electronic workinglength determination with direct anatomic workinglength measurement. One study reported an accuracyof 96.5% (–0.5 to 0.0 mm from the apical foramen).414

Another study reported an accuracy of 85% (± 0.5 mmfrom the apical foramen).358

Figure 10-62 Modern electrical apex locator that displays A, by digital readout, distance of the file tip to the cementodentinal junction intenths of millimeters; B, “O” reading, flashing red light, and pulsing tone when the cementodentinal junction is reached. C, If the apical con-striction is penetrated, a yellow warning light flashes, a visual “E” (error) is displayed, and an audio alarm warns the dentist. (Courtesy ofFormatron/Parkell Products, Inc., Farmingdale, N.Y.)

Figure 10-63 Endex (aka APIT), the original third-generationapex locator. It measures the impedance between two currents andworks in a “wet” canal with sodium hypochlorite. (Courtesy ofOsada Electric Co.)

Page 117: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 521

The Pratten and McDonald in vitro study of teeth inhuman cadavers compared Endex determinations toradiograph estimations and to direct anatomic work-ing length measurements. The Endex was slightly morereliable than the radiographic technique: 81% of theEndex determinations were –0.5 to 0.0 mm from theapical constriction in the study.399

Two in vivo studies compared the Endex determina-tions to radiographic working length estimations. Onestudy reported that 63% of the determinations were –1.0 to 0.0 mm from the radiographic apex,409 where-as the other study reported an accuracy of 89.6% (± 0.5mm from the apical constriction) in moist canals.415

One in vivo study reported that the Endex could beused to determine working length under various con-ditions, such as bleeding, exudate, and hypochlorite inthe canals.420 Four studies reported on the comparisonof Endex determinations and direct anatomic measure-ments. Two of the studies reported an accuracy of 72%and 93%, respectively (± 0.5 mm from the apical fora-men).364,418 A third study reported that about 66% ofthe determinations were –0.75 to 0.0 mm from the api-cal constriction and the determinations were unaffect-ed by pulp status.417 The fourth study reported that thedeterminations were “coincident” with the minor fora-men in 37% of the canals and short in 47%.397

The Neosono Ultima Ez Apex Locator (Satelec Inc;Mount Laurel, N.J.) is a third-generation device thatsupersedes the second-generation Sono-Explorer line. Tocircumvent the Japanese patents of two alternating cur-rent frequencies, Amadent developed a device with mul-tiple frequences and implanted a microchip that sorts outtwo of the many frequencies to give an accurate readingin either wet or dry canals. It works best in the presenceof sodium hypochlorite. The Ultima-Ez is mounted witha root canal graphic showing file position as well as anaudible signal. The ability to “set” the digital readout at0.5 or 1.0 mm allows measurements of wide open canalsas well. The Ultima-Ez also comes with an attached pulptester, called the Co-Pilot (Amadent; Cherry Hill, N.J.).To date, the Dental Advisor (Ogden, Utah) has had fiveconsultants who used the device 26 times and reported itsreliability to be better in wet canals than in dry. They alsostated that it was “Quick and easy to use.”

The Mark V Plus (Moyco/Union Broach, MillerDental, Bethpage, N.Y.) is identical in circuitry andperformance to the Neosono Ultima Ez. To date, noevaluations of the device have been published.

The JUSTWO or JUSTY II (Toesco Toei EngineeringCo./Medidenta, Woodside, N.Y. and Japan) is anotherthird-generation apex locator. The device uses frequen-cies of 500 and 2,000 Hz in a “relative value method.”421

Two electric potentials are obtained that correspond totwo impedances of the root canal. These two potentialsare converted to logarithmic values, and one is subtract-ed from the other. The result drives the meter. Therationale of the JUSTWO resembles that of the RootZX.422 The analog meter and audio indicator display theposition of the instrument tip inside the canal. The unitdetermines working length in the presence of elec-trolytes. Although no calibration is required, a calibra-tion check is recommended.

Two in vitro studies have been reported on thisdevice. In one, in which electronic measurements werecompared to radiographic working length, the meandistance from the radiographic apex was 0.98 ± 0.44mm. In the other study, the device showed an averagedeviation of 0.04 ± 0.05 mm from the direct anatomicworking length measurement.423

The APEX FINDER A.F.A. (“All Fluids Allowed”—Model 7005, Sybron Endo/Analytic; Orange, Calif.)uses multiple frequencies and comparative impedanceprinciples in its electronic circuitry (Figure 10-64). It isreported to be accurate regardless of irrigants or fluidsin the canals being measured. It has a liquid crystal dis-play (LCD) panel that indicates the distance of theinstrument tip from the apical foramen in 0.1 mmincrements. It also has an audio chime indicator. Thedisplay has a bar graph “canal condition indicator” thatreflects canal wetness/dryness and allows the user to

Figure 10-64 The Apex Finder A.F.A. (All Fluids Allowed) third-generation apex locator. It functions best with an electrolyte presentand displays, on an LCD panel, the distance of the file tip from theapex in 0.1 mm increments. (Courtesy of Sybron Endo/Analytic.)

Page 118: Ch10: ENDODONTIC CAVITY PREPARATION

improve canal conditions for electronic working lengthdetermination.424 The Endo Analyzer 8005 combineselectronic apex location and pulp testing in one unit.

McDonald et al. reported an in vitro study of theApex Finder A.F.A.425 The device was able to locate thecementodentinal junction or a point 0.5 mm coronalto it with 95% accuracy.

The ROOT ZX (J. Morita Mfg. Co.; Irvine, Calif. andJapan), a third-generation apex locator that uses dual-frequency and comparative impedance principles, wasdescribed by Kobayashi (Figure 10-65)387,388 The elec-tronic method employed was the “ratio method” or“division method.” The Root ZX simultaneously meas-ures the two impedances at two frequencies (8 and 0.4kHz) inside the canal. A microprocessor in the devicecalculates the ratio of the two impedances. The quo-tient of the impedances is displayed on an LCD meterpanel and represents the position of the instrument tipinside the canal. The quotient “was hardly influencedby the electrical conditions of the canal but changedconsiderably near the apical foramen.”388

The Root ZX is mainly based on detecting the changein electrical capacitance that occurs near the apical con-striction.388 Some of the advantages of the Root ZX arethat it requires no adjustment or calibration and can beused when the canal is filled with strong electrolyte orwhen the canal is “empty” and moist. The meter is aneasy-to-read LCD. The position of the instrument tipinside the canal is indicated on the LCD meter and by themonitor’s audible signals. The Root ZX, as well as sever-al other apex locators, allows shaping and cleaning of theroot canal with simultaneous, continuous monitoring ofthe working length.371,387,388,419,426–429

Several studies have reported on the accuracy andreliability of the Root ZX.392,403,412,430–432 In thesestudies, electronic working length determinationsmade by the Root ZX were compared with directanatomic working length mesurements. Three studiesreported an accuracy for the device that ranged from84 to 100% (± 0.5 mm from the apical fora-men).392,412,430 Murphy et al. used the apical constric-tion as the ideal apical reference point in the canal andreported an accuracy of 44% in the narrow tolerancerange of 0.0 to + 0.5 mm from the apical constric-tion.402 One study reported that the Root ZX showedless average deviation than a second-generation device(Sono-Explorer Mark III) tested.432

Studies on the Root ZX “display increment marks”reiterate that the Root ZX display is a relative scale anddoes not indicate absolute intracanal distances fromthe apical constriction. In clinical practice, the 0.5-increment mark is often taken to correspond to the api-

522 Endodontics

cal constriction, but, according to the manufacturer,the 0.5-increment mark is an average of –0.2 to 0.3 mmbeyond the apical constriction.428 The operatinginstructions for the Root ZX state, “The working lengthof the canal used to calculate the length of the fillingmaterial is actually somewhat shorter. Find the lengthof the apical seat (i.e., the end point of the filling mate-rial) by subtracting –0.5-1.0 mm from the workinglength indicated by the 0.5 reading on the meter.”428

They suggested that the Root ZX should be used withthe 0.0 or “APEX” increment mark as the most accurateapical reference point. The clinician should then adjustthe working length on the endodontic instrument forthe margin of safety that is desired (ie, 1 mm short).

A number of in vitro and in vivo studies on the accu-racy and reliability of the Root ZX have been report-ed.397,401,433–438 Electronic working length determina-tions made with the Root ZX were compared withdirect anatomic working length measurements afterextraction of the teeth in the study. Four studies indi-cated an accuracy for the Root ZX in the range of 82 to100% (± 0.5 mm from the apical foramen).433–438 Onestudy reported an accuracy of 82% (± 0.5 mm from theapical constriction).401 McDonald et al. reported thatthe Root ZX demonstrated 95% accuracy in their studywhen the parameters were –0.5 to 0.0 mm from thecementodentinal junction.425

Combination Apex Locator and EndodonticHandpiece. The Tri Auto ZX (J. Morita Mfg. Corp.USA; Irvine, Calif.) is a cordless electric endodontichandpiece with a built-in Root ZX apex locator(Figure 10-66).439 The handpiece uses nickel-titaniumrotary instruments that rotate at 280 ± 50 rpm.440 Theposition of the tip of the rotary instrument is continu-ously monitored on the LED control panel of the hand-piece during the shaping and cleaning of the canal.

The Tri Auto ZX has three automatic safety mech-anisms. The handpiece automatically starts rotationwhen the instrument enters the canal and stops whenthe instrument is removed (auto-start-stop mecha-nism). The handpiece also automatically stops andreverses the rotation of the instrument when thetorque threshold (30 grams/centimeter) is exceeded(auto-torque-reverse mechanism), a mechanismdeveloped to prevent instrument breakage. In addi-tion, the handpiece automatically stops and reversesrotation when the instrument tip reaches a distancefrom the apical constriction that has been preset bythe clinician (auto-apical-reverse mechanism), amechanism controlled by the built-in Root ZX apexlocator and developed to prevent instrumentationbeyond the apical constriction.

Page 119: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 523

The Tri Auto ZX has four modes. In the ElectronicMeasurement of Root (EMR) mode, a lip clip, hand file,and file holder are used with the apex locator in thehandpiece to determine working length. The handpiecemotor does not operate in this mode. In LOW mode, thetorque threshold is lower than in the HIGH mode. TheLOW mode is used with small to mid-sized instrumentsfor shaping and cleaning the apical and mid-third sec-tions of the root canal. All three automatic safety mech-anisms are functional in this mode. In HIGH mode, thetorque threshold is higher than the LOW mode butlower than the MANUAL mode. The HIGH mode isused with mid-size to large instruments for shaping andcleaning in the mid-third and coronal-third sections ofthe root canal. All three automatic safety mechanismsare functional in this mode. MANUAL mode offers thehighest threshold of torque. In MANUAL mode, the

auto-start-stop and the auto-torque-reverse mecha-nisms do not function. The auto-apical-reverse mecha-nism does function. MANUAL mode is generally usedwith large instruments for coronal flaring.

Kobayashi et al. suggested that “to get the bestresults, it may be necessary to use some hand instru-mentation” in combination with the Tri Auto ZX,depending on the difficulty and morphology of theroot canal being treated.439

In vitro, the accuracy of the EMR mode of the TriAuto ZX to determine working length to the apicalconstriction has been reported at 0.02 ± 0.06 mm.441

Another in vitro study reported that about half of thecanals studied were short (–0.48 ± 0.10 mm) and halfwere long (+ 0.56 ± 0.05).431 A second study conclud-ed that shaping and cleaning with the Tri Auto ZX(AAR mechanism set at 1.0) consistently approximated

Figure 10-65 Root ZX third-generation apex loca-tor with accessories (left) and extra accessories(right). The Root ZX microprocessor calculates theratio of two impedances and displays a file’s approachto the apex on a liquid crystal display. It functions inboth a “dry” or canal “wet” with electrolyte. (Courtesyof J. Morita Mfg. Co.)

Figure 10-66 The Tri-Auto ZX is primarily a cord-less, automatic, endodontic handpiece with a built-inRoot ZX apex locator. The position of the nickel-tita-nium rotary instrument tip is constantly being mon-itored and displayed on the LED control panel. Abuilt-in safety feature stops and reverses the motorwhen the apex is approached by the tip of the file.Accessories include (left) an AR contra-angle lubri-cant with a dispensing cap and apex locator attach-ments. Additional accessories (right). (Courtesy of J.Morita Mfg. Co.)

Page 120: Ch10: ENDODONTIC CAVITY PREPARATION

the apical constriction.442 The accuracy was reported tohave 95% “acceptable” measurements (± 0.5 mm) in astudy that compared the direct anatomic workinglength with the electronic working length.443

The accuracy of the level of instrumentation with theTri Auto ZX (J. Morita Mfg. Corp. USA; Irvine, Calif.) wasreported in an in vivo study.444 The canals were shapedand cleaned with the Tri Auto ZX (low mode) with theauto-apical-reverse mechanism set at 1.0. In all cases, radi-ographs showed that the preinstrumentation workinglength was within 0.5 mm of the final instrument workinglength and without overextension of gutta-percha, instru-ment breakage, or canal transportation.

Other Apex-Locating Handpieces. Kobayashi et al.reported the development of a new ultrasonic rootcanal system called the SOFY ZX (J. Morita Mfg. Corp.;Irvine, Calif.), which uses the Root ZX to electronicallymonitor the location of the file tip during all instru-mentation procedures.445,446 The device minimizes thedanger of overinstrumentation.

The Endy 7000 (Ionyx SA, Blanquefort Cedex,France) is available in Europe. It is an endodontic hand-piece connected to an Endy apex locator that reverses therotation of the endodontic instrument when it reaches apoint in the apical region preset by the clinician.

Other Uses of Apex Locators. Sunada suggestedthe possibility of using apex locators to detect root per-forations.376 It was later reported that Electronic ApexLocators (EALs) could accurately determine the loca-tion of root or pulpal floor perforations.447,448 Themethod also aided in the diagnosis of external resorp-tion that had invaded the dental pulp space or internalresorption that had perforated to the external root sur-face.367 A method for conservative treatment of rootperforations using an apex locator and thermal com-paction has been reported.449

An in vitro study to test the accuracy of the Root ZXto detect root perforations compared with other typesof apex locators reported that all of the apex locatorstested were acceptable for detection of root perfora-tions.450 No statistical significance was found betweenlarge perforations and small perforations. Prepared pinholes can be checked by apex locators to detect perfo-ration into the pulp or into the periodontal liga-ment.451 Horizontal or vertical root fractures couldalso be detected as well as post perforations.

In this latter case, the EAL file holder is connected toa large file, and the file then contacts the top of the post.The Root ZX will sound a single sustained beep, andthe word “APEX” will begin flashing.

An in vivo study has evaluated the usefulness of anapex locator in endodontic treatment of teeth with

524 Endodontics

incomplete root formation requiring apexification.452

They reported that in all cases, the EAL was 2 to 3 mmshort of the radiographic apex at the beginning ofapexification therapy. When the apical closure wascomplete, the apex locator was then 100% accurate. Incases of immature teeth with open apices, a studyreported that apex locators were inaccurate.453 In con-trast, an in vivo study using absorbent paper points forestimating the working lengths of immature teeth hasbeen described.454 They reported that in 95% of thecases for which the working length was estimated bypaper points, they were within 1 mm of the workinglength estimated by radiographs.

An in vitro study evaluated the accuracy of the RootZX in determining working length in primary teeth.455

Electronic determinations were compared with directanatomic and radiographic working lengths. Theyreported that the electronic determinations were simi-lar to the direct anatomic measurements (–0.5 mm).Radiographic measurements were longer (0.4 to 0.7mm) than electronic determinations.

Apex locators can be very useful in management ofinpatients and outpatients. For example, they can be animportant tool in endodontic treatment in the operat-ing room. They also reduce the number of radi-ographs, which may be important for those who arevery concerned about radiation hygiene. In somepatients, such concern is so strong that dental radi-ographs are refused. An apex locator can be of enor-mous value in such situations.

Contraindications. The use of apex locators, andother electrical devices such as pulp testers, electrosur-gical instruments, and desensitizing equipment, is con-traindicated for patients who have cardiac pacemak-ers. Electrical stimulation to the pacemaker patient caninterfere with pacemaker function. The severity of theinterference depends on the specific type of pacemakerand the patient’s dependence on it.456 In special cases,an apex locator may be used on a patient with a pace-maker when it is done in close consultation with thepatient’s cardiologist.457

The Future. The future of apex locators is verybright. Significant improvement in the reliability andaccuracy of apex locators took place with the develop-ment of third-generation models. It is probable thatmore dentists will now use apex locators in the man-agement of endodontic cases. At this time, however, theconclusions of studies have not demonstrated thatapex locators are clearly superior to radiographic tech-niques, nor can they routinely replace radiographs inworking length determination. It has been demonstrat-ed that they are at least equally accurate.399

Page 121: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 525

Studies have concluded that when apex locators areused in conjunction with radiographs, there is a reduc-tion in the number of radiographs required365,408,458 andthat some of the problems associated with radiographicworking length estimation can be eliminated.459

An understanding of the morphology in the apicalone-third of the canal is essential.299–308,311,312

Consideration should be given to adopting the parame-ter of 0.5 to 0.0 mm (from the apical constriction) as themost ideal apical reference point in the canal. Electronicworking length determinations should be accomplishedwith multiple measurements and should be done in con-junction with the shaping and cleaning procedure.Consideration should be given to the evaluation of theaccuracy of obturation as an indicator of the accuracy ofthe working length determination. Future apex locatorsshould be able to determine working length in all electricconditions of the root canal without calibration. Themeter display on future apex locators should accuratelyindicate how many millimeters the endodontic instru-ment tip is from the apical constriction.371

TECHNIQUES OF RADICULAR CAVITY PREPARATION

Over the years, there has been a gradual change in theideal configuration of a prepared root canal. At onetime, the suggested shape was round and tapered,almost parallel, resembling in silhouette an obelisk likethe Washington Monument, ending in a pyramidmatching the 75-degree point of the preparatoryinstruments. After Schilder’s classic description of“cleaning and shaping,” the more accepted shape forthe finished canal has become a gradually increasingtaper, with the smallest diameter at the apical constric-ture, terminating larger at the coronal orifice.460

This gradually increasing taper is effective in final fill-ing for as Buchanan pointed out, the “apical movementof the cone into a tapered apical preparation…onlytightens the apical seal.”461 But, as Buchanan furthernoted, “overzealous canal shaping to achieve this taperhas been at the expense of tooth structure in the coronaltwo-thirds of the preparation leading to perforations”and, one might add, materially weakening the tooth.461

Grossly tapered preparations may well go back to Berg,an early Boston endodontist, who enlarged canals toenormous size to accommodate large heated pluggersused to condense warm sectional gutta-percha.462

Step-Back or Step-Down?

As previously stated, two approaches to débriding andshaping the canal have finally emerged: either starting atthe apex with fine instruments and working one’s way

back up (or down) the canal with progressively largerinstruments—the “step-back” or serial technique—orthe opposite, starting at the cervical orifice with largerinstruments and gradually progressing toward the apexwith smaller and smaller instruments—the “step-down”technique, also called “crown-down” filing.

Hybrid approaches have also developed out of thetwo methods. Starting coronally with larger instru-ments, often power driven, one works down the straightcoronal portion of the canal with progressively smallerinstruments—the step-down approach. Then, at thispoint, the procedure is reversed, starting at the apexwith small instruments and gradually increasing in sizeas one works back up the canal—the step-backapproach. This hybrid approach could be called, quiteclumsily, the step-down-step-back technique or “modi-fied double-flared technique.” 463

Any one of these methods of preparing the root canalwill ensure staying within the confines of the canal anddelivering a continuously tapered preparation and, asBuchanan noted, eliminate blocking, “apical ledging,transportation, ripping, zipping and perforation.”464

Step-Back Preparation. Weine, Martin, Walton,and Mullaney were early advocates of step-back, alsocalled telescopic or serial root canal preparation.465–468

Designed to overcome instrument transportation inthe apical-third canal, as described earlier (Figure 10-67), it has proved quite successful. When Weine coinedthe term “zip” to describe this error of commission, itbecame a “buzz word,” directing attention to apicalaberrant preparations, principally in curved canals.Walton has depicted these variations, ranging fromledge to perforation to zip (Figure 10-68). The damagenot only destroys the apical constriction, so importantto the compaction of the root canal filling, but also pro-duces an hourglass-shaped canal.469 In this, the nar-rowest width of the canal is transported far away fromthe apex and prevents the proper cleansing and fillingof the apical region (see Figure 10-68). In the case ofseverely curved canals, perforation at the curve’s elbowleads to disastrous results (Figure 10-69).

Step-Back Preparation and Curved Canals. Thismethod of preparation has been well described byMullaney.468 His approach has been modified, however,to deliver a continuing tapered preparation.461

Mullaney divided the step-back preparation into twophases. Phase I is the apical preparation starting at theapical constriction. Phase II is the preparation of theremainder of the canal, gradually stepping back whileincreasing in size. The completion of the preparation isthe Refining Phase IIA and IIB to produce the continu-ing taper from apex to cervical (Figure 10-70).

Page 122: Ch10: ENDODONTIC CAVITY PREPARATION

526 Endodontics

Although the step-back technique was designed toavoid zipping the apical area in curved canals, it appliesas well to straight canal preparation. As Buchanannoted, “all root canals have some curvature. Evenapparently straight canals are usually curved to somedegree.”461 Canals that appear to curve in one directionoften curve in other directions as well (Figure 10-71).

Prior to the introduction of nickel-titanium files,one of the first axioms of endodontics has been to“always use a curved instrument in a curved canal.” Thedegree and direction of the curve are determined by thecanal shadow in the radiograph. Buchanan has madean art of properly curving instruments to match the

Figure 10-67 A, Incorrect enlargement of the apical curve leads tocavitation. Larger, stiffer instruments transport preparation at theexternal wall. B, Ovoid cavitation (arrow) developed by incorrectcleaning and shaping.

Figure 10-68 Hazards of overenlarging the apical curve. A, Small flexible instruments (No. 10 to No. 25) readily negotiate the curve. B,Larger instruments (No. 30 and above) markedly increase in stiffness and cutting efficiency, causing ledge formation. C, Persistent enlarge-ment with larger instruments results in perforation. D, A “zip” is formed when the working length is fully maintained and larger instrumentsare used. (Courtesy of Dr. Richard E. Walton.)

Figure 10-69 Apical curve to the buccal of the palatal root wentundetected and was perforated by heavy instruments and thenoverfilled. Right-angle radiographs failed to reveal buccal or lingualcurves. Step-back preparation could have prevented perforation.(Courtesy of Dr. Richard E. Walton.)

A

B

A B C D

Page 123: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 527

canal silhouette in the film.461,464 He made the pointthat the bladed part of the file must be bent all the way,even up to the last half millimeter, remembering “thatcanals curve most in the apical one-third”470 (Figure10-72). One must also remember that the most difficultcurves to deal with are to the buccal and/or the lingual

for they are directly in line with the x-ray beam. Theirapical orifices appear on the film well short of the rootapex. So, curving the file to match the canal is para-mount to success in the step-back maneuver unlessnickel-titanium files are used. Attempting to curvenickel-titanium files can introduce metal fatigue.

Figure 10-70 Step-back preparation. A, Phase I—Apical preparation up to file No. 25 with recapitulation using prior size files. B, Phase II—Stepping-back procedure in 1 mm increments, Nos. 25 through 45. Recapitulation with a No. 25 file to full working length. C, Refining PhaseII-A—Gates-Glidden drills Nos. 2, 3, and 4 used to create coronal and midroot preparations. D, Refining Phase II-B—No. 25 file, circum-ferential filing smooths step-back. E, Completed preparation—a continuous flowing flared preparation from the cementodentinoenameljunction to the crown. Adapted with permission from Mullaney TP.468

Page 124: Ch10: ENDODONTIC CAVITY PREPARATION

Step-Back, Step-by-Step—Hand Instrumentation.Phase I. To start Phase I instrumentation, it must beassumed that the canal has been explored with a finepathfinder or instrument and that the working lengthhas been established—that is, the apical constrictionidentified. The first active instrument to be insertedshould be a fine (No. 08, 10, or 15) 0.02, tapered, stain-less steel file, curved and coated with a lubricant, suchas Gly-Oxide, R.C. Prep, File-Eze, Glyde, K-Y Jelly, orliquid soap. The flexibilty of nickel titanium does notlend itself to this pathfinding function in sizes smallerthan No. 15.

The motion of the instrument is “watch winding,”two or three quarter-turns clockwise-counterclockwiseand then retraction. On removal, the instrument iswiped clean, recurved, relubricated, and repositioned.“Watch winding” is then repeated. Remember that theinstrument must be to full depth when the cuttingaction is made. This procedure is repeated until theinstrument is loose in position. Then the next size K file

528 Endodontics

is used—length established, precurved, lubricated, andpositioned. Again, the watch-winding action andretraction are repeated. Very short (1.0 mm) filingstrokes can also be used at the apex. At the University ofTennessee, nickel-titanium 0.02 tapered instrumentswere shown to be effective when used with this tech-nique. Nickel-titanium files were not curved and main-tained the canal shape better than stainless steel.

It is most important that a lubricant be used in thisarea. As Berg462 and Buchanan461 pointed out, it is oftenfibrous pulp stumps, compacted into the constricture,that cause apical blockage. In very fine canals, the irrig-ant that will reach this area will be insufficient to dis-solve tissue. Lubrication, on the other hand, emulsifiestissue, allowing instrument tips to macerate and removethis tissue. It is only later in canal filing that dentin chipspack apically, blocking the constriction. By then the api-cal area has been enlarged enough that sodiumhypochlorite can reach the debris to douche it clear.

By the time a size 25 K file has been used to fullworking length, Phase I is complete. The 1.0 to 2.0 mmspace back from the apical constriction should be cleanof debris (Figure 10-73) unless this area of the canalwas large to begin with, as in a youngster. Then, ofcourse, larger instruments are used to start with.

Using a number 25 file here as an example is not toimply that all canals should be shaped at the apical

Figure 10-71 A, Unsuspected aberration in canal anatomy is notapparent in a standard buccolingual radiograph. B, The severe bay-onet shape of a canal seen in a mesiodistal radiograph should bedetermined by careful exploration. Also note the apical delta.

Figure 10-72 A, Stainless steel file series appropriately bent forcontinuously tapering preparation. Note that the instrument shaftstraightens more and more with size increase. B, The file on the leftis bent for straight or slightly curved canals. The file on the right isbent to initially explore and negotiate abrupt apical canal curva-tures. Reproduced with permission from Buchanan LS.464

A B

Page 125: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 529

restriction only to size 25. Hawrish pointed out theapparent lack of interest in canal diameter versus thegreat interest in the proper canal length (personal com-munication, 1999). Many, in fact most, canals should beenlarged beyond size 25 at the apical constriction in orderto round out the preparation at this point and remove asmuch of the extraneous tissue, debris, and lateral canalsas possible. A size 25 file is used here as an example andas a danger point for beyond No. 25 lies danger!

As stainless steel instruments become larger, theybecome stiffer. Metal “memory” plus stress on theinstrument starts its straightening. It will no longer staycurved and starts to dig, to zip the outside (convex) wallof the canal.

It must be emphasized here that irrigation betweeneach instrument use is now in order, as well as recapit-ulation with the previous smaller instrument carried tofull depth and watch wound. This breaks up the apicaldebris so that it may be washed away by the sodiumhypochlorite. All of these maneuvers (curved instru-ments, lubrication, cleaning debris from the usedinstrument, copious irrigation, and recapitulation) willensure patency of the canal to the apical constriction.

Phase II. In a fine canal (and in this example), thestep-back process begins with a No. 30 K-style file. Itsworking length is set 1 mm short of the full workinglength. It is precurved, lubricated, carried down thecanal to the new shortened depth, watch wound, andretracted. The same process is repeated until the No. 30is loose at this adjusted length (Figure 10-74).Recapitulation to full length with a No. 25 file follows toensure patency to the constriction. This is followed bycopious irrigation before the next curved instrument isintroduced. In this case, it is a No. 35, again shortenedby 1.0 mm from the No. 30 (2.0 mm from the apical No.25). It is curved, lubricated, inserted, watch wound, andretracted followed by recapitulation and irrigation.

Thus, the preparation steps back up the canal 1 mmand one larger instrument at a time. When that portionof the canal is reached, usually the straight midcanal,where the instruments no longer fit tightly, thenperimeter filing may begin, along with plenty of irriga-tion (Figure 10-75).

It is at this point that Hedstroem files are most effec-tive. They are much more aggressive rasps than the Kfiles. The canal is shaped into the continuous taper soconducive to optimum obturation. Care must be takento recapitulate between each instrument with the orig-inal No. 25 file along with ample irrigation.

This midcanal area is the region where reshapingcan also be done with power-driven instruments:Gates-Glidden drills, starting with the smaller drills(Nos. 1 and 2) and gradually increasing in size to No. 4,5, or 6. Proper continuing taper is developed to finishPhase IIA preparation. Gates-Glidden drills must beused with great care because they tend to “screw” them-selves into the canal, binding and then breaking. Toavoid this, it has been recommended that the largersizes be run in reverse. But, unfortunately, they do notcut as well when reversed. A better suggestion is tolubricate the drill heavily with RC-Prep or Glyde,which “will prevent binding and the rapid advanceproblem.” Lubrication also suspends the chips andallows for a better “feel” of the cutting as well as the firstcanal curvature. Used Gates-Glidden drills are also lessaggressive than new ones.

Figure 10-73 Apical limitations of instrumentation should be atthe apical constriction, which is about 0.5 to 1.0 mm from theanatomic (radiographic) end of the root.

Figure 10-74 A stylized step-back (telescopic) preparation. Aworking length of 20 mm is used as an example. The apical 2 to 3mm are prepared to size 25. The next 5 mm are prepared with suc-cessively larger instruments. Recapitulation with No. 25 to fulllength between each step. The coronal part of the canal is enlargedwith circumferential filing or Gates-Glidden drills. Reproducedwith permission from Tidmarsh BG. Int Endod J 1982;15:53.

Page 126: Ch10: ENDODONTIC CAVITY PREPARATION

Newer instruments with various tapers from 0.04 to0.08 mm/mm of taper are now available for this purposeas well and can be used as power-driven or hand instru-ments. With any of the power-driven instruments, usingthem in a passive pecking motion will decrease thechances of binding or screwing into the canal.

Refining Phase IIB is a return to a size No. 25 (or thelast apical instrument used), smoothing all around thewalls with vertical push-pull strokes, to perfect thetaper from the apical constriction to the cervical canalorifice. In this case, a safe-ended, noncutting-tipHedstroem file is the most efficient. It produces a gooddeal of dentin chips, however, that must be broken upat the apex with a cutting-tip K file and then flushedout with abundant sodium hypochlorite.

At this point, Buchanan recommended that sodiumhypochlorite be left in place to the apex for 5 to 10 min-utes. This is the only way in which the auxiliary canalscan be cleaned.461 Hand-powered Gates-Glidden drills(Handy Gates) or LIGHTSPEED instruments may be

530 Endodontics

used for this final finish, as well as the new handpieceOrifice Openers or Gates-Glidden drills. Gutmann andRakusin pointed out that the “final preparation shouldbe an exact replica of the original canal configuration—shape, taper, and flow, only larger”471(Figure 10-76, A).So-called “Coke-bottle” preparations should be avoidedat all cost (Figure 10-76, B).

This completes the chemomechanical step-backpreparation of the continuing taper canal. It is nowready to be filled or medicated and sealed at the coro-nal cavity until the next appointment. If it is to befilled, the smear layer should first be removed. Thisprocedure is detailed in chapter 11.

Modified Step-Back Technique. One variation ofthe step-back technique is more traditional. The prepa-ration is completed in the apical area, and then thestep-back procedure begins 2 to 3 mm up the canal.This gives a short, almost parallel retention form toreceive the primary gutta-percha point when lateralcondensation is being used to fill the canal. Thegutta-percha trial point should go fully to the constric-tion, and a slight tug-back should be felt when thepoint is removed (retention form). This shows that itfits tightly into the last 2 to 3 mm of the prepared canal.

Efficacy of the Step-Back Technique. Threeresearch groups tested the efficacy of the step-backmaneuver. Using the techniques detailed here (precurv-ing, watch winding, and step-back), a Swiss group stat-ed that the “step back shapings consistently presentedthe best taper and apical stop design…”472 In markedcontrast, two groups from Great Britain used straight,not precurved, instruments in “simple in/out fil-ing…with no attempt at rotation or twisting.”473 BothBritish groups reported preparations that were hour-glass in shape, and one had a deformation and instru-ment breakage as well as severe zipping in the apicalarea473–475 (Figure 10-77).

These findings, using stainless steel files, emphasizethe necessity of precurving instruments and using limit-ed rotation for enlargement in the apical region. Vesseyfound that a limited reaming action (as recommendedabove) produced a circular preparation, whereas filesused vertically as files (rasps) produced ovoid prepara-tions.476 Others found essentially the same477,478 (Figure10-78). In Scotland, W. P. and E. M. Saunders achievedbetter results using a step-down/step-back approachrather than straight step-back instrumentation. On theother hand, they broke a number of files using the mod-ified approach.463 Positive findings have been notedusing nickel-titanium instruments. They seem to main-tain canal shape better and improved cutting efficiencywhen used as a reamer.

Figure 10-75 A, Perimeter filing action used to débride and shapelarger ovoid portions of the canal. The file is used in anup-and-down rasping action with pressure exerted cross-canalagainst all walls. B, Cross-section showing shaping of an ovoidcanal. This “multiple exposure” illustration shows how the file isused as a rasp against walls around the entire perimeter of the canal.Only a small area remains to be cleaned and shaped. A stainless steelHedstroem file is best suited for this purpose.

A

B

Page 127: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 531

Figure 10-76 Preparation configurations. A, Originalcanal shape, taper and flow, only larger. B (right), “Cokebottle” preparation from overuse of Gates-Glidden drills orPeeso reamers negates the efficient flow of gutta-percha.Reproduced with permission from Gutmann JL andRakusin H.471

Figure 10-77 Composite print of an original curvedcanal (dark). Overlay details areas of instrument diver-gence (white). Note the hourglass shape, apical zip, andapical elbow as a result of straight filing with straightinstruments. Reproduced with permission from AlodehMHA et al.475

Page 128: Ch10: ENDODONTIC CAVITY PREPARATION

Chelation and Enlargement. A number of canals,particularly fine curved canals, will appear to be almostcalcified or blocked by attached pulp stones. They maystill be negotiated if the clinician uses a chelating agentand the utmost patience.

Ethylenediaminetetraacetic acid buffered to a pH of7.3 was long ago advocated by Nygaard-Østby to “dis-solve” a pathway for exploring instruments.275,479 Whenthe mineral salts have been removed from the obstruct-ing dentin by chelation, only the softened matrixremains.480 This may be removed by careful watch-wind-ing action to “drill” past the obstruction. This maneuvermay be improved if the coronal portion of the canal iswidened so that only the instrument tip is cutting.

Files with tapers greater than the traditional 0.02mm/mm have made negotiating these “calcified” canalsmore predictable. Calcification occurs nearest the irri-tant to which the pulp is reacting. Since most irritantsare in the coronal region of the pulp, the farther apicalone goes into the canal, the more unlikely it is to be cal-cified. When files bind in these canals, it may be from

532 Endodontics

small constrictions in the coronal part of the canal. Ifworking length is estimated to be 20 mm but the clini-cian can negotiate only 10 mm of canal, increasing thetaper of the canal to the 10 mm level often removes theconstrictions and allows a small file to negotiate fartherinto the canal. This is one of the strengths of followingthe step-down or crown-down technique.

Fraser has shown that, contrary to popular belief,chelating agents “do not soften dentin in the narrow partsof the canal,” although softening can occur in the cervicaland middle portions.481,482 Ethylenediaminetetraaceticacid must be concentrated enough in an area to be effective.

R C Prep, File-Eze, and Glyde, which contain EDTA,act more as lubricating agents since the concentrationof EDTA contained therein is very modest. The CanalFinder System, using No. 08 files, has been very effec-tive in opening curved calcified canals in the presenceof an EDTA lubricant.

Selden and McSpadden have recommended the useof a dental operating microscope for peering down

Figure 10-78 A, Ovoid canal shape in a “young” mandibular molar sectioned just below the floor of the pulp chamber. The distal canal(top) and the mesiobuccal canal (lower left) both require perimeter filing to complete their preparation. Watch-winding or reaming actionalone would accurately shape mesiolingual canal (lower right) into a round tapered preparation. B, “Dumbbell”-shaped canal that could notaccurately be enlarged into a round tapered preparation. Perimeter filing action and multiple gutta-percha point filling would be required toaccurately shape and obturate this shape of a canal. Tactile sensation with a curved exploring instrument should inform the operator that heis not dealing with a round tapered canal. (Note related abscess, upper left.)

A B

Page 129: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 533

“calcified” canals.483,484 More recently, the fiber-opticendoscope, such as used in abdominal and brain sur-gery, has given dentists a whole new look at the pulpalfloor and the root canal. The OraScope (SpectrumDental Inc; North Attlebora, Mass.), for example, has a0.9 mm fiber-optic probe that will penetrate down theroot canal, displaying its view, enormously magnified,on a computer screen. Incidentally, there is recent evi-dence that root canal calcification may be associatedwith long-term prednisone therapy (60 mg per dayover 8 years to treat lupus erythematosus).485

Step-Down Technique—Hand Instrumentation

Initially, Marshall and Pappin advocated a“Crown-Down Pressureless Preparation” in whichGates-Glidden drills and larger files are first used inthe coronal two-thirds of the canals and then progres-sively smaller files are used from the “crown down”until the desired length is reached486 This has becomeknown as the step-down or crown-down technique ofcleaning and shaping. It has risen in popularity, espe-cially among those using nickel-titanium instrumentswith varying tapers.

A primary purpose of this technique is to minimizeor eliminate the amount of necrotic debris that could beextruded through the apical foramen during instru-mentation. This would help prevent post-treatment dis-comfort, incomplete cleansing, and difficulty in achiev-ing a biocompatible seal at the apical constriction.486

One of the major advantages of step-down prepara-tion is the freedom from constraint of the apicalenlarging instruments. By first flaring the coronal two-thirds of the canal, the final apical instruments areunencumbered through most of their length. Thisincreased access allows greater control and less chanceof zipping near the apical constriction.487 In addition,it “provides a coronal escapeway that reduces the “pis-ton in a cylinder effect” responsible for debris extrusionfrom the apex.488

Step-Down, Step-by-Step. In this method, theaccess cavity is filled with sodium hypochlorite, andthe first instrument is introduced into the canal. Atthis point, there is a divergence in technique dictatedby the instrument design and the protocol for pro-ceeding recommended by each instrument manufac-turer. All of the directions, however, start with explo-ration of the canal with a fine, stainless steel, .02 taper(No. 8, 10, 15, or 20 file, determined by the canalwidth), curved instrument. It is important that thecanal be patent to the apical constriction before clean-ing and shaping begin. Sometimes the chosen file willnot reach the apical constriction, and one assumes that

the file is binding at the apex. But, more often thannot, the file is binding in the coronal canal. In thiscase, one should start with a wider (0.04 or 0.06 taper)instrument or a Gates-Glidden drill to free up thecanal so that a fine instrument may reach the mid- andapical canal. This would be the beginning of step-down preparation. Buchanan has also emphasized theimportance of removing all pulp remnants beforeshaping begins to ensure that this tissue does not “pileup” at the constriction and impede full cleaning andshaping to that point.461

K-File Series Step-Down Technique. As statedabove, the initial penetrating instrument is a small,curved, stainless steel K file, exploring to the apical con-striction and establishing working length. To ensurethis penetration, one may have to enlarge the coronalthird of the canal with progressively smaller Gates-Glidden drills or with instruments of larger taper suchas the .04 or the .06 instruments. At this point, and inthe presence of sodium hypochlorite and/or a lubricantsuch as Glyde, step-down cleaning and shaping beginswith K-Flex, Triple-Flex, or Safety Hedstrom (SybronEndo/Kerr; Orange, Calif.) instruments in either the0.02, 0.04, or 0.06 taper configuration depending onthe canal size to begin with. Starting with a No. 50instrument (for example) and working down the canalto, say, a size No. 15, the instruments are used in awatch-winding motion until the apical constriction (orworking length) is reached. When resistance is met tofurther penetration, the next smallest size is used.Irrigation should follow the use of each instrument andrecapitulation after every other instrument. To proper-ly enlarge the apical third, and to round out ovoidshape and lateral canal orifices, a reverse order ofinstruments may be used starting with a No. 20 (forexample) and enlarging this region to a No. 40 or 50(for example). The tapered shape can be improved bystepping back up the canal with ever larger instru-ments, bearing in mind all the time the importance oflubrication, irrigation, and recapitulation. At thispoint, the canal should be ready for smear layerremoval, drying, and either medication or obturation.

Modified Technique. There have been a number ofmodifications of the step-down technique since it was firstpromulgated. One of the most recent was by Ruddle (per-sonal communication, 2001). Following complete access,he suggested that clinicians “face-off” the orifices with anappropriately sized Gates-Glidden drill. This creates asmooth guide path to facilitate the placement of subse-quent instruments. Certain canal systems contain deepdivisions and may be initially opened at their coronal endswith Micro Openers (Dentsply Maillefer; Tulsa, Okla.).

Page 130: Ch10: ENDODONTIC CAVITY PREPARATION

If the pulp is vital, a broach may be selected toquickly extirpate it if space permits. At this stage oftreatment, the coronal two-thirds of any canal shouldbe “scouted” with a No. 10 or 15 curved, stainless steelK file in the presence of a lubricant and/or sodiumhypochlorite. Exploration of this portion of the canalwill confirm straight-line access, cross-sectional diam-eter, and root canal system anatomy. Files are used seri-ally to flare the canal until sufficient space is generatedto safely introduce either Gates-Gliddens or nickel-tita-nium rotary shaping files. Frequent irrigation withsodium hypochlorite and recapitulation with a No. 10file will discourage canal blockage and move debrisinto solution, where it can be liberated from the rootcanal system. One way to accomplish pre-enlargementof the canal is with Gates-Glidden drills that are used atapproximately 800 rpm, serially, passively, and like abrush to remove restrictive dentin. Initially, one shouldstart with a Gates-Glidden drill No. 1 and carry eachlarger instrument short of the previous instrument topromote a smooth, flowing, tapered preparation.Frequent irrigation with sodium hypochlorite andrecapitulation with a small clearing file to preventblockage are in order.

Following pre-enlargement, Ruddle believes in nego-tiating the apical one-third last, establishing patency,and confirming working length. He then recommendsfinishing the apical zone so that there is a smooth uni-form taper from the orifice level to the radiographic ter-minus. He emphasized that a variety of instrumentsmay be used to create the “deep shape.” If the clinicianchooses 0.02 tapered files to “finish” the apical one-third, Ruddle uses a concept he calls “Gauging andTuning.” “Gauging” is knowing the cross-sectionaldiameter of the foramen that is confirmed by the size ofinstrument that “snugs in” at working length. “Tuning”is ensuring that each sequentially larger instrument uni-formly backs out of the canal 1⁄2 mm.

After removing the sodium hypochlorite, the canal isrinsed with 17% aqueous EDTA to remove the smearlayer in preparation for obturation. Dentsply Mailleferhas developed a “Clean & Shape” Kit that contains all ofthe instruments necessary for this technique.

PROFILE GT (Greater Taper) Technique. If theseinstruments (Dentsply/Tulsa Dental; Tulsa, Okla.) areused, Buchanan, the developer, recommends that onestart with a 0.10 GT instrument to flare out the coronalthird of the canal. This means that this instrument is anISO size 20 at the tip, but the taper is 0.10 mm/mm, thatestablishes a wider freedom for those instruments tofollow. The instrument is used in a twisting motion, firstcounterclockwise and then clockwise with apical pres-

534 Endodontics

sure, before retraction. The instrument is cleaned andthe operation repeated until the instrument is loose. Alubricant such as RC PREP or GLYDE should be used.At this point, the canal should be flooded with EDTAand the next smaller-size GT file is used, number 0.08,in the same manner—counterclockwise, engage, twistclockwise, and retract. One continues down the canalusing the 0.08, and 0.06 taper instruments until the api-cal restriction is reached. Constant irrigation with sodi-um hypochlorite is most important! This constituteswhat Buchanan terms the “Second Shaping Wave,” andit should be completed in a matter of minutes.

The second wave is followed by the “Third ShapingWave,” in which regular ISO instruments are used tothe constriction to enlarge the apical canal diameterbeyond size 20, the tip diameter of the GT files.Beginning with fine instruments, and then steppingback 1 or 2 mm with instruments, up to size 35 or 40,the apical region is “rounded out.” The final shaping isa return of the last GT file used in the canal.

Buchanan pointed out that the GT instruments aresized to fit certain size canals. The 0.06 file, for instance,is recommended for “extremely thin or curved roots.”The 0.08 file is best for lower anterior teeth, multirootedpremolars, and the buccal roots of maxillary molars. The0.10 file better matches the distal canal of mandibularmolars, the palatal roots of maxillary molars, single-canal premolars, mandibular canines, and maxillaryanterior teeth. The 0.12 instrument is for larger canals.

Buchanan is a great believer in the necessity of clean-ing what he terms the “patency zone,” that tiny spacebetween the apical constriction and the apical terminus.For this, in the presence of sodium hypochlorite, hecarefully instruments this space with a regular No. 10file. He also believes that sodium hypochlorite shouldbe present in this region for a total of 30 minutes. Ifpreparation time has been less than 30 minutes, he rec-ommends that a final lavage should remain in the canaluntil 30 minutes have passed. This, in his view, dissolvesthe final debris and tissue packed there, even in theaccessory canals (personal communication, 2001).

Quantec Instrument Technique. Using Quantecinstruments (Sybron Endo/Analytic; Orange, Calif.),which are more reamer like than files, the recommendedtechnique for hand instrumentation is divided into threephases: negotiation, shaping, and apical preparation.

NEGOTIATION: As is standard with virtually allcleaning and shaping techniques, the canal, in the pres-ence of sodium hypochlorite, is first explored with astandard No. 10 or 15 0.02 taper, curved, stainless steelK file and working length is established (Figure 10-79,A). Exploration is followed by a Quantec No. 25, 0.06

Page 131: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 535

taper, nickel-titanium instrument, advanced in a ream-ing action, from the canal orifice to just short of theapical third, and followed by irrigation with sodiumhypochlorite (Figure 10-79, B and C).

With a standard ISO 0.02, stainless steel, No. 10 or15 file, a “Glide Path” for the instruments to follow isdeveloped to working length (Figure 10-79, D). Thecanal is then irrigated with EDTA (Figure 10-79, E),and the No. 20 and 25 stainless steel, 0.02 instrumentsare used to clean and shape the apical third to the api-cal constriction. This is followed again by copious irri-gation (Figure 10-79, F).

SHAPING: Using lubricants and sodium hypochlo-rite, one returns to the Quantec instruments, all withan ISO size No. 25 tip. Returning to the No. 25, 0.06taper instrument, it is used in a reaming action, as fardown the canal as it will comfortably go (Figure 10-79,G). It is followed in succession by the No. 0.05 taperQuantec and then the 0.04 and 0.03 tapers until theapical stop is reached (Figure 10-79, H to J). Copiousirrigation follows the use of each instrument.

QUANTEC APICAL PREPARATION: To ensure accuracy,the working length should be rechecked. If an apicalpreparation larger in diameter than a No. 25 is desired,one may return to the 0.02 taper Quantec instruments(which will now be quite loose in the midcanal), andthe diameter of the apical third can then be enlarged upto a size No. 40, 45, or 50, depending on the originalsize of the canal (Figure 10-79, K). Final irrigation toremove the smear layer with EDTA and sodiumhypochlorite prepares the tapered canal for medicationor filling (Figure 10-79, L).

Efficacy of the Step-Down Technique. Comparedto the step-back “circumferential filing technique withprecurved files as described by Weine,”488 Morgan andMontgomery found the step-down technique signifi-cantly better in shape and terminus.489

Another in vitro study found significantly less debrisextruded from the apical orifice when step-down pro-cedures were used compared to step-back procedures.Neither technique was totally effective, however, in pre-venting total debris extrusion.490

Variation of the Three Basic Preparations

A variety of techniques have been developed, all basedon the step-down, step-back, or hybrid approach topreparation. Most are inspired by new canal instru-ments and/or vibratory devices.

Balanced Force Concept Using Flex-R Files. Aftermany years of experimentation, Roane et al. introducedtheir Balanced Force concept of canal preparaton in1985.100 The concept came to fruition, they claimed,

with the development and introduction of a new K-type file design, the Flex-R File100,101 (Moyco UnionBroach). The technique can be described as “position-ing and pre-loading an instrument through a clockwiserotation and then shaping the canal with a counter-clockwise rotation.”100 The authors evaluated damagedinstruments produced by the use of this technique.They discovered that a greater risk of instrument dam-age was associated with clockwise movement.85

For the best results, preparation is completed in astep-down approach. The coronal and mid-thirds of acanal are flared with Gates-Glidden drills, sizes 2through 6, and then instrument shaping is carried intothe apical areas. This approach is less difficult than theconventional step-back technique. Increasing thediameter of the coronal and mid-thirds of a canalremoves most of the contamination and providesaccess for a more passive movement of hand instru-ments into the apical third. Shaping becomes less diffi-cult: the radius of curvature is increased as the arc isdecreased. In other words, the canal becomes straighterand the apex accessible with less flexing of the shapinginstruments (Figure 10-80).

After mechanical shaping with Gates-Glidden drills,balanced force hand instrumentation begins: placing,cutting, and removing instruments using only rotarymotions (Figure 10-80, C). Insertion is done with aquarter-turn clockwise rotation while slight apicalpressure is applied (Figure 10-81, 1). Cutting is accom-plished by making a counterclockwise rotation, “againwhile applying a light apical pressure (Figure 10-81, 2).The amount of apical pressure must be adjusted tomatch the file size (ie, very light for fine instruments tofairly heavy for large instruments).”100 Pressure shouldmaintain the instrument at or near its clockwise inser-tion depth. Then counterclockwise rotation and apicalpressure act together to enlarge and shape the canal tothe diameter of the instrument. Counterclockwisemotion must be 120 degrees or greater. It must rotatethe instrument sufficiently to move the next larger cut-ting edge into the location of the blade that preceded it,in order to shape the full circumference of a canal. Agreater degree of rotation is preferred and will morecompletely shape the canal to provide a diameter equalto or greater than that established by the counterclock-wise instrument twisting during manufacture.

It is important to understand that clockwise rotation“sets” the instrument, and this motion should notexceed 90 degrees. If excess clockwise rotation is used,the instrument tip can become locked into place andthe file may unwind. If continued, when twisted coun-terclockwise, the file may fail unexpectedly. The process

Page 132: Ch10: ENDODONTIC CAVITY PREPARATION

536 Endodontics

Figure 10-79 Step-down technique, with Quantec hand instruments, cleaning and shaping. A, Explore to the apex and establish workinglength (WL) with a stainless steel (SS) No. 10 or 15 0.02 taper file. B, Enlarge the orifices and two-thirds of the way down the canal with a nick-el-titanium (NiTi) No. 25 0.06 taper file. C, Irrigate all of the canals with sodium hypochlorite (NaOCl). D, Establish a “glide path” to WL withSS No. 15, 0.02 taper file. E, Irrigate with ethylenediaminetetraacetic acid (EDTA). F, Enlarge to WL with SS No. 20 and 25 0.02 files. Irrigatewith NaOCl. G, With Glyde and NaOCl, enlarge down the canal as far as possible with NiTi No. 25 0.06 file. Irrigate. H, Continue further downthe canal with a NiTi No. 25 0.05 file. I, Continue further with a No. 25 0.04 file. J, Continue to WL with a NiTi No. 25 0.03 file. K, Enlargeapical one-third up to size Nos. 40, 45, or 50 with 0.02 taper files. L, Final irrigation with EDTA and NaOCl to remove smear layer. Dry.

Page 133: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 537

is repeated (clockwise insertion and counterclockwisecutting), and the instrument is advanced toward theapex in shallow steps. After the working depth isobtained, the instrument is freed by one or more coun-terclockwise rotations made while the depth is heldconstant. The file is then removed from the canal witha slow clockwise rotation that loads debris into the

flutes and elevates it away from the apical foramen.100

Generous irrigation follows each shaping instrumentsince residual debris will cause transportation of theshape. Debris applies supplemental pressures againstthe next shaping instrument and tends to causestraightening of the curvature.

Repeating the previously described steps, the clini-cian gradually enlarges the apical third of the canal byadvancing to larger and larger instruments. Workingdepths are changed between instruments to producean apical taper. The working loads can and should bekept very light by limiting the clockwise motion andthereby reducing the amount of tooth structureremoved by each counterclockwise shaping move-ment. This technique can and should be used withminimal force.

The balanced force technique can be used with any K-type file491; however, the shaping and transportation con-trol are maximum when a Flex-R file is used.492 The Flex-R file design incorporates a guiding plane and removesthe transition angles inherent on the tip of standard K-type files (see Figure 10-23). Those angles, if present,enable the tip to cut in an outward direction and give itthe ability to cut a ledge into the canal wall. Lacking a

Figure 10-80 a, File displays full curvature of the canal before radicular access is modified. b, Radicular access is completed with a descend-ing series of Gates-Glidden drills progressing toward the apex in 2.0 mm or less increments. c, The dotted line indicates the original curva-ture, whereas the file displays the affective curvature after radicular access is improved. This modification materially reduces the difficulty ofapical shaping. (Courtesy of Dr. James B. Roane.)

Figure 10-81 1. For a balanced force motion, the file is pushedinwardly and rotated one quarter-turn clockwise. 2. It is then rotat-ed more than one half-turn counterclockwise. The inward pressuremust be enough to cause the instrument to maintain depth andstrip away dentin as it rotates counterclockwise. These alternatemotions are repeated until the file reaches working length.(Courtesy of Dr. James B. Roane.)

Page 134: Ch10: ENDODONTIC CAVITY PREPARATION

sharp transition angle, Flex-R files follow the canal andare prevented from gouging into the walls. The tip designcauses a Flex-R file to hug the inside of a curve and pre-vents tip transport into the external wall of that curve.493

Balanced force instrumentation was born out ofnecessity because Roane firmly believes in enlarging theapical area to sizes larger than generally practiced. Heexpects a minimum enlargement of size 45, 1.5 mmshort of the foramen in curved canals, and size 80 inlarger single-rooted teeth (Figure 10-82). These sizes, ofcourse, depend on root bulk, fragility, and the extent ofcurvature. Sabala and Roane also believe in carrying thepreparation through to “full length,” the radiographicapex of the root. They “purposely” shape the foraminalarea, and yet patients rarely experience flareups.494 Astep-back in 1⁄2-mm increments is used with at least twogroups of instruments to form an apical control zone.

538 Endodontics

This shaping provides a minimum diameter at a knowndepth within the canal. A size 45 control zone is shapedby first expending a size 15 and 20 file to the periodon-tal ligament and then reducing the working depth by 0.5mm for sizes 25, 30, and 35 and completing the apicalshape 1 mm short using sizes 40 and 45. It goes withoutsaying that sodium hypochlorite irrigation is used.Single-appointment preparation and obturation are derigeur and also play an important role in the formationof these shaping concepts.

The success of this shaping technique and enlargingscheme has been closely evaluated in both clinical prac-tice and student clinics. Clinical responsiveness isimpressive, and the efficiency has been unmatched untilrotary shaping (Figure 10-83).

Efficacy of Balanced Force Preparation. Sabala andRoane reported that, using the balanced force concept,

Figure 10-82 Details of the final balanced force step-back preparation in the apical control zone. Apical constriction is formed at a meas-ured depth for small, medium, or large canals. Root length (RL) and millimeters of step-back are shown left. Instrument size is shown right.(Courtesy of Dr. James B. Roane.)

Figure 10-83 Impressive result of balanced force canal preparation and obturation. A, Instruments in place demonstrating canal curvature.B, Final obturation to extended sizes is more assurance that the canals have been thoroughly débrided. (Courtesy of Dr. James B. Roane.)

A B

Page 135: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 539

students at the University of Oklahoma could enlargecanals (in a laboratory exercise) with no measurable api-cal transportation.494 Moreover, the modified-tip instru-ment (Flex-R file) developed a nontransported prepara-tion more frequently and predictably. Procedural acci-dents occurred in 16.7% of the samples.493 In a previouspublication, the authors concluded that most instru-ments damaged by students (91.5%) using balancedforce technique were damaged by overzealous clockwiserotation.85

A University of Washington balanced force study,using standard K-type files, concluded that “effectiveinstrumentation of curved root canals may be accom-plished with straight instruments of fairly large sizewithout significant deviation from the original canalposition.” The original canal position was maintained80% of the time after shaping with a No. 40 file.Original position was maintained in only 40% when asize 45 file was the final apical instrument.491 A secondUniversity of Washington study compared balancedforce and step-back techniques. This study disclosedthat Balanced Force using Flex-R prototype files pro-duced significantly less deviation from the center of theoriginal canal than did the step-back method usingconventional K-type and Hedstroem files.492 Theauthors noted that no instrument separations wereexperienced in this study.

McKendry at the University of Iowa reported thatthe Balanced Force technique débrided the apical canalat least as adequately as the step-back filing techniqueand as well as the CaviEndo ultrasonic method.Furthermore, significantly less debris was extrudedapically using balanced force compared to sonic orstep-back preparations.495,496 While testing theBalanced Force method at Georgia, the investigatorsfound that early radicular flaring (step-back) madeinstrumentation much easier but did not necessarilyimprove the quality of the apical shape.497

It has been well established that the Balanced Forcetechnique using guiding-tip files is fast and efficient.However, Balanced Force, like any new technique,should be practiced before it is used clinically. If exces-sive pressure is used, instrument separation may result.The large radicular shaping provided by use of Gates-Glidden drills, if improperly guided, might cause astrip perforation into the furcation. Use in undergrad-uate clinics has proven this technique reliable and safefor routine use. Once mastered, Balanced Force tech-nique expands the shaping possibilities and extendsone’s operative abilities.

Ultrasonic and Sonic Preparations. Ultrasonic.As stated before, ultrasonic instrumentation today is

used primarily in final canal débridement. For canalcleanliness, ultrasonic activation with a No. 15 file for 3full minutes in the presence of 5% sodium hypochlo-rite produced “smooth, clean canals, free of the smearlayer and superficial debris along their entirelength.”498 This is exactly the technique used by a num-ber of dentists seeking the cleanest canals in spite ofwhich clean and shape technique they might have used.This should be done after the smear layer has beenremoved to ensure that all of the detritus, includingbacteria, is all flushed out.

Concern over the possible harmful effects of sodiumhypochlorite spilling out of the apical foramen was dealtwith at the State University of Louisiana. Investigatorsintentionally overinstrumented past the apex in a mon-key study and then evaluated the tissue response whensodium hypochlorite was used with conventional filingversus ultrasonic filing/irrigation. They were pleased tofind no significant difference between the two methodsand a low to moderate inflammatory response.499

Sonic. Sonic canal preparation and débridementwith the Micro Mega 1500 Sonic Air (MicroMega/MediDenta, France/USA) handpiece has beenquite popular, particularly with the military. Camp hasconsiderable experience with the Sonic handpiece andinstruments and recommended that stainless steelhand files size 10 or 15 first be used to establish a path-way down the canals until resistance is met, usuallyabout two-thirds of the canal length. He then beginsthe step-down approach with the sonic instruments—the No. 15 Shaper or Rispisonic file (see Figure 10-34),their length set 2 mm shy of the length reached with theprevious instrument. About 30 seconds are spent ineach canal using a quick up and down, 2 to 3 mmstroke and circumferentially filing under water irriga-tion supplied by the handpiece. This is the time toremove any isthmus or fins between canals. The use ofeach instrument is followed by copious sodiumhypochlorite irrigation. The water from the handpieceis turned off and the irrigant is agitated in the canalwith the fine Sonic file.

At this point, working length is established by a radi-ograph or an electric apex locator, and the extension tothe apical constriction is carried out with stainless steelhand files to full working length—Nos. 15, 20, 25, and30. Following sodium hypochlorite irrigation, Campreturns to the Sonic No. 15 (or a 20 or 25 in largercanals) Shaper or Rispisonic file for 30 seconds in eachcanal. After irrigation, No. 30, 35, and 40 hand files areagain used followed by a larger Sonic instrument, andthen No. 50 to 60 hand files are used to step-back up thecanal to ensure a tapered preparation. Final use of the

Page 136: Ch10: ENDODONTIC CAVITY PREPARATION

small Sonic file, with copious sodium hypochlorite tothe constriction, removes the remaining debris and fil-ings. Recapitulation with a No. 20 hand file will checkthe correct length of tooth and the apical stop at the con-striction. After final irrigation, the canal is dried withpaper points and is ready for medication or filling as thecase may be (personal communication, 2001).

Efficacy and Safety of Ultrasonic/Sonic Preparations.The Iowa faculty tested step-back versus step-downapproach with ultrasonic and sonic devices. Theyfound that the ultrasonic instruments produced abetter preparation when the step-back approach wasused. The step-down preparation was preferred forsonic preparation.500

Another group of clinicians compared step-down,step-back hand instrumentation versus ultrasonic andsonic preparations. Both hand methods, as well as sonicenlargement, caused the extrusion of debris apically. Inranking from least to worst extrusion, Sonic was 1, best;step-down was 2; ultrasonic was 3; and conventional,circumferential, step-back preparation was 4, worst.216

Finally, a French group evaluated the degree of leakagefollowing obturation of canals prepared with the SonicAir unit using Shaper Sonic files versus hand preparation.The researchers found that the highest degree of leakageoccurred overall with the manual method; however, bothmethods leaked apically. They felt that the smear layerpresent might have been responsible.501

ROTARY INSTRUMENTATION USING NICKEL TITANIUM

Over the past few years, the movement toward usingrotary nickel-titanium instruments for root canalpreparation has resulted in a multitude of instrumen-tation systems in the marketplace. The manufacture ofvariably tapered and “Gates-Glidden-like,” flexiblenickel-titanium instruments, for use in gear-reduction,slow-speed handpieces, either air driven or electric, hasenabled the skilled clinician to deliver predictable canalshapes (Figure 10-84) with enhanced speed andincreased efficiency.502–510

Problems associated with hand and rotary instru-mentation with stainless steel have plagued both gen-eralists and endodontists for years; these include (1)too many instruments and steps needed to generate thedesired shape, thus increasing the time of canal prepa-ration; (2) each resultant shape will be different, mak-ing obturation less predictable; (3) canal transporta-tion naturally results as instruments increase in diame-ter and stiffness; and (4) the use of traditional coronalenlargement burs such as Gates-Glidden drills cancause excessive dentin removal.

540 Endodontics

Although nickel-titanium endodontic rotaryinstruments do overcome some of these shortcomingsassociated with stainless steel instruments, the clini-cian must also understand that nickel-titanium is notcompletely “fail-safe”; one must be aware of the factthat although nickel-titanium files are flexible, nickel-titanium metal, like any other metal, will eventuallyfatigue and fail when it becomes overstressed, especial-ly during rotation in curved root canals511–514 or ifimproperly used or abused (see Figure 10-20, B). Inturn, strict monitoring of instrument use in all sys-tems should be maintained so that nickel-titaniumfiles can be periodically disposed of prior to failure.512

In fact, single use (ie, use one time per case) in severe-ly curved or calcified canals should be the rule. Inaddition, care must be taken to use these systems asper the manufacturer’s instructions (eg, a step-downapproach with light pressure is essential when usingnickel-titanium rotary instruments).

It is also important to understand that these systemsrequire a significant learning curve to achieve masteryand are not deemed to be a panacea.

ProFile 0.04 and 0.06 Taper Rotary Instruments andProFile Orifice Shapers

ProFile 0.04 and 0.06 Taper Rotary Instruments andProFile Orifice Shapers (Dentsply/Tulsa Dental; Tulsa,Okla.) are proportionately sized nickel-titanium U-shaped instruments (Figure 10-85) designed for use ina controlled, slow-speed, high-torque, rotary hand-piece.504,509,510,515 Although a study by Gabel et al.demonstrated four times more file separation/distor-tion at 333 rpm than at 166 rpm, the preferred speed

Figure 10-84 Comparison in the efficacy of two different methodsof cleaning and shaping. Left, Preparation using nickel-titaniumrotary instrumentation leaves a perfectly round canal thoroughlydébrided. Right, Preparation using stainless steel K-type files in astep-back sequence. Note the uneven shape and possible debris.(Courtesy of Dr. Sergio Kuttler.)

Page 137: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 541

range is still from 275 to 325 rpm.516 As these moretapered instruments are rotated, they produce an accel-erated step-down preparation, resulting in a funnel-form taper from orifice to apex. As these “reamers”rotate clockwise, pulp tissue and dentinal debris areremoved and travel counterclockwise back up theshaft. As a result, these instruments require periodicremoval of dentin “mud” that has filled the “U” portionof the file.

The U-blade design, similar in cross-section to theLightSpeed, has flat outer edges that cut with a planingaction, allowing it to remain more centered in the canalcompared to conventional instruments (Figure 10-86).504–506,509,510,515 The ProFile tapers also have abuilt-in safety feature, in which, by patented design,they purportedly unwind and then wind up backwardprior to breaking. These Profile Variable Taper instru-ments are manufactured in standard ISO sizing as wellas Series 29 standards (ie, every instrument increases29% in diameter).

The Orifice Shapers, in 0.06 and 0.07 mm/mm tapers,are designed to replace Gates-Glidden drills for shapingthe coronal portion of the canal. Because of theirtapered, radial-landed flutes and U-file design, theseinstruments remain centered in the canal while creatinga tapering preparation. In turn, this preflaring allows formore effective cleaning and shaping of the apical half ofthe canal with the Profile Series 0.04 Tapers.

In contrast to Profile Tapers, however, the totallength of the Orifice Openers is 19 mm, with a cuttinglength of approximately 9 mm. Besides reducing fileseparation, this shorter length also makes them easierto manipulate in difficult access areas. ISO tip sizes of30, 40, and 50 are built into these files with tapers of0.06 and 0.07. These instruments serve the same func-tion as the Quantec Flares.

The ProFile Variable Taper has a 60-degree bullet-nose tip that smoothly joins the flat radial lands.

Figure 10-85 ProFile instrument sequence showing Orifice shapers and 0.04 tapers. (Courtesy of Dentsply/Tulsa Dental.)

Figure 10-86 Comparative cross-sectional shapes between a U-shaped Profile 0.04 taper with a 90-degree rake angle and the con-ventional triangular reamer with a 60-degree cutting angle.(Courtesy of Dentsply/Tulsa Dental.)

Page 138: Ch10: ENDODONTIC CAVITY PREPARATION

Although these tapers have a 90-degree cutting angle(Figure 10-87), the nonaggressive radial landed flutesgently plane the walls without gouging and self-thread-ing; in addition, they are cut deeper to add flexibilityand help create a parallel inner core of metal. Thus,when the Profile Taper is rotated, stresses become moreevenly distributed along the entire instrument in con-trast to a nonparallel core or tapered shaft of a conven-tional instrument in which stresses are more concen-trated toward the tip of its narrow end. An investiga-tion by Blum, Mactou et al., however, demonstratedthat torque can still develop at the apical 3 mm of theProFiles even when used in a step-down procedure.517

ProFile instruments are available in either 0.04(double taper) or 0.06 (triple taper) over the ISO 0.02taper. Kavanaugh and Lumley found no significant dif-ferences between the 0.04 and 0.06 tapers with respectto canal transportation. On the other hand, the use of0.06 tapers improved canal shape.515 The 0.04 is moresuitable for small canals and apical regions of mostcanals, including the mesial roots of mandibularmolars and buccal roots of maxillary molars. The 0.06is recommended for the midroot portions of mostcanals, distal roots of mandibular molars, and palatalroots of maxillary molars. Similar to the graduatingtaper technique of the Quantec Series, the clinician hasthe option of using alternating tapers within a singlecanal (ie, combinations of 0.04, 0.06, and 0.07 taperProFile instruments).

Since the development of the ProFile tapers, a num-ber of methods for use have been espoused. As such,there is currently no recommended “stand-alone” tech-nique. In fact, a number of clinicians incorporate the

542 Endodontics

Profile System near the end of the canal preparation toblend the apical preparation with coronal preflare.

Canal Preparation

A basic technique that primarily uses Orifice Shapersand Profile tapers is as follows: Once access, canalpatency, and an estimated working length have beendetermined, the No. 30 0.06 taper Orifice Shaper istaken several millimeters into the canal, thus creatinga pathway for the next instruments. The No. 50 0.07Orifice Shaper is then used to create more coronalflare followed by the No. 40 0.06 taper OrificeShaper. This last instrument should be advancedabout halfway down the canal using minimal pres-sure. Constant irrigation and recapitulation must befollowed throughout the entire sequence.

A working length radiograph is then taken with astainless steel hand file to determine the precise length.The tip of all subsequent tapers becomes a guide as theinstrument cuts higher up the shaft, mostly with the mid-dle blades. In all cases, a ProFile taper file should never beused in the canal longer than 4 to 6 seconds. The clini-cian must now passively advance the 0.04 or 0.06 taperinstruments, or combinations thereof, to or near theworking length. As the rotary reamers move closer tolength, a funnel shape is imparted to the canal walls. Inmost cases, a No. 30 or an equivalent 29 Series 0.04 tapereventually reaches at or near the working length withminimal resistance. In more constricted cases, however, aNo. 25 or 20 0.04 taper may be the first to reach the work-ing length. If the tapers are not taken to full workinglength, hand files, either stainless steel or nickel-titanium,can be used to complete the apical 1 to 2 mm.

ProFile GT Rotary Instrumentation

ProFile GT (Greater Taper) Rotary Files(Dentsply/Tulsa Dental; Tulsa, Okla.) are made of nick-el-titanium alloy, and their intended purpose is to cre-ate a predefined shape in a single canal. Designed byDr. Steven Buchanan and also available as hand files,these uniquely engineered files are manufactured in0.06, 0.08, 0.10, and 0.12 tapers, all having a constantISO noncutting tip diameter of 0.20 mm (ISO size 20)to ensure maintenance of a small apical preparation(Figure 10-88). They have variably pitched, radial-landed, clockwise cut U-blade flutes that provide ream-er-like efficiency at the shank with K-file strength attheir tips (ie, they have closed flute angles at their tipsand more open flute angles at their shank ends). Theopen flute angles at the shank end also tend to reducethe file’s ability to thread into the canal, a typical prob-lem that occurs with other rotary designs. The maxi-

Figure 10-87 Scanning electron micrograph of a Profile GTdepicting a 60-degree bullet-nosed tip. The tip allows for a smoothtransition angle where the tip meets the flat radial lands. (Courtesyof Dentsply/ Tulsa Dental.)

Page 139: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 543

mum flute diameter is also set at 1.0 mm, safely limit-ing coronal enlargement.

Because the GT files vary by taper but have the sametip diameters and maximum flute diameters, the flutelengths become shorter as the tapers increase. The 0.06taper is designed for moderate to severely curved canalsin small roots, the 0.08 taper for straight to moderatelycurved canals in small roots, and the 0.10 taper forstraight to moderately curved canals in large roots. A setof three accessory GT files (see Figure 10-88) is availablefor unusually large root canals having apical diametersgreater than 0.3 mm. These instruments have a taper of0.12 mm per mm, a larger maximum flute diameter of1.5 mm, and varying tip diameters of 0.35, 0.50, and0.70 mm. When used in canals with large apical diame-ters, they are typically able to complete the whole shapewith one file. The ProFile GT files are thus designed sothat the final taper of the preparation is essentiallyequivalent to the respective GT file used.

A recent study (unpublished, 2000) conducted at theUniversity of Pacific found that undergraduate dentalstudents, who were trained in the GT rotary technique,completed shapes in 75% less time than with standardK files and Gates-Glidden drills. Shapes were alsorounder throughout their lengths, and coronal canalshaping was more conservative.

Canal Preparation. According to the manufactur-er, the ProFile GT technique can be broken down into

three steps: step-down with ProFile GTs and then stepback with ProFile 0.04 taper files and a GT file to createfinal canal shape. As in all rotary techniques, a step-down approach is used once initial negotiation is com-pleted with hand files and lubricant. Standard GT files(0.12, 0.10, 0.08, and 0.06 tapers) are then used in astep-down manner at 150 to 300 rpm, allowing each tocut to their passive lengths.

Working length should be determined once the GTfile has reached two-thirds of the estimated length ofthe canal. In some cases, the 0.06 taper will reach fulllength. Since the standard GT files all have a 0.20 mmtip diameter, the 0.08 and 0.10 taper files should easilygo to length if a 0.08 or 0.10 taper is desired for thatparticular canal.

Rather than using the GT file to the apical terminus,a variation of the technique involves the creation of anapical taper. ProFile 0.04 taper instruments, usuallysizes 25 to 35, can be used in a step-back fashion, start-ing about 2 mm short of working length. The standardGT files can then be used in a step-down fashion againto create the final canal shape right to working length,or, if preferred, hand instruments may be used to shapethe apical 2 mm of the canal. If additional coronal flareis needed, an appropriate GT accessory file can be used.

With the ProFile GT rotary instrumentation tech-nique, as with most other nickel-titanium rotary tech-niques, basic rules need to be adhered to. Speeds must

Figure 10-88 Profile GT Rotary sizes and tapers of the standard GT: 0.06, 0.08, 0.10, and 0.12 mm/mm tapers with a common ISO size 20tip and the Accessory files with a common 0.12 mm/mm taper but variable tips of ISO sizes 35, 50, and 70. (Courtesy of Dentsply/TulsaDental.)

Page 140: Ch10: ENDODONTIC CAVITY PREPARATION

be kept constant, a light touch must be used, the GTfiles should not be used in a canal more than 4 to 6 sec-onds, and irrigation and lubrication must be continu-ally used throughout the procedure.

ProTaper Rotary System

According to the developers, ProTaper (ProgressivelyTapered), nickel-titanium rotary files substantially sim-plify root canal preparation, particularly in curved andrestricted canals. The claim is made that they consis-tently produce proper canal shaping that enables pre-dictable obturation by any vertical obturation method.This new instrument system, consisting of three “shap-ing” and three “finishing” files, was co-developed byDrs. Clifford Ruddle, John West, Pierre Mactou, andBen Johnson and was designed by François Aeby andGilbert Rota of Dentsply/Maillefer in Switzerland.

The distinguishing feature of the ProTaper System(Dentsply/Tulsa Dental) is the progressively variabletapers of each instrument that develop a “progressivepreparation” in both vertical and horizontal directions.Under use, the file blades engage a smaller area ofdentin, thus reducing torsional load that leads toinstrument fatigue and file separation. During rota-tion, there is also an increased tactile sense when com-pared with traditionally shaped rotary instruments.“Taper lock” is reportedly reduced, extending a newlyfound freedom from concern about breakage. As withany new system, however, the ProTaper beginner isadvised to first practice on extracted teeth with restrict-ed curved canals.

ProTaper Configurations. As previously stated,the ProTaper System consists of only six instrumentsizes: three shaping files and three finishing files.

Shaping Files. The Shaping Files are labeled S-X, S-1, and S-2. The S-X Shaper (Figure 10-89, A) is an aux-iliary instrument used in canals of teeth with shorterroots or to extend and expand the coronal aspects ofthe preparation, similar to the use of Gates-Gliddendrills or orifice openers. The S-X has a much increasedrate of taper from D0 (tip diameter) to D9 (9.0 mmpoint on the blades) than do the other two shapers, S-1 and S-2. At the tip (D0), the S-X shaper has an ISOdiameter of 0.19 mm. This rises to 1.1 mm at D9 (com-parable to the tip size of a size 110 ISO instrument).After D9, the rate of taper drops off up to D14, whichthins and increases the flexibility of the instrument.

The S-1 and S-2 files start at tip sizes of 0.17 mm and0.20 mm, respectively, and each file gains in taper up to1.2 mm (Figure 10-89, B). But unlike the consistentincrease of taper per millimeter in the ISO instruments,the ProTaper Shapers have increasingly larger tapers

544 Endodontics

each millimeter over the 14 mm length of their cuttingblades. This is what makes the instruments unique.

Shaping File S-1 is designed to prepare the coronalone-third of the canal, whereas Shaping File S-2enlarges and prepares the middle third in addition tothe critical coronal region of the apical third.Eventually, both size instruments may also help enlargethe apical third of the canal as well.

Finishing Files. The three finishing files have beendesigned to plane away the variations in canal diame-ter in the apical one-third. Finishing Files F-1, F-2,and F-3 have tip diameters (D0) of ISO sizes 20, 25,and 30, respectively. Their tapers differ as well (Figure10-89, C). Between D0 nd D3, they taper at rates of0.07, 0.08, and 0.09 mm/mm, respectively. From D4 toD14, each instrument shows a decreased taper thatimproves its flexibility.

Although primarily designed to finish the apicalthird of the canal, finishers do progressively expand themiddle third as well. Generally, only one instrument isneeded to prepare the apical third to working length,and tip sizes (0.20, 0.25, or 0.30) will be selected basedon the canal’s curvature and cross-sectional diameter.Finisher F-3 has been further engineered to increase itsflexibility in spite of its size (Figure 10-89, D).

ProTaper Benefits.

1. The progressive (multiple) taper design improvesflexibility and “carving” efficiency, an importantasset in curved and restrictive canals (Figure 10-89, E).

2. The balanced pitch and helical angles of the instru-ment optimize cutting action while effectivelyaugering debris coronally, as well as preventing theinstrument from screwing into the canal.

3. Both the “shapers” and the “finishers” remove thedebris and soft tissue from the canal and finish thepreparation with a smooth continuous taper.

4. The triangular cross-section of the instrumentsincreases safety, cutting action, and tactile sensewhile reducing the lateral contact area between thefile and the dentin (Figure 10-89, F).

5. The modified guiding instrument tip can easily fol-low a prepared glide path without gouging side walls.

Canal Preparation.ProTaper System: Guidelines for Use

1. Prepare a straight-line access cavity with no restric-tions in the entry path into the chamber.

2. Fill the access cavity brimful with sodiumhypochlorite and/or ProLube.

Page 141: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 545

Figure 10-89 The ProTaper File Rotary System. A, Shaping File X, an auxiliary instrument used primarily to extend canal orifices andwiden access as well as create coronal two-thirds shaping in short teeth. B, Shaping Files 1 and 2, used primarily to open and expand thecoronal and middle thirds of the canal. C, Finishing Files 1, 2, and 3, used to expand and finish the apical third of progressively larger canals.D, Finishing File 3 is used to finish the apical third of larger canals. A No. 30 file is used to gauge the apical opening. Recapitulation with aregular No. 30 instrument, followed by liberal irrigation, is most important. E, The flexibility and cutting ability of nickel-titanium ProTaperRotary Files are assets in preparing curved constricted canals. F, Triangular cross-section presents three sharp blade edges that improve cut-ting ability and tactile sense. Reproduced with permission from ADVANCED ENDODONTICS video and Drs. John West and CliffordRuddle. (Color reproduction courtesy of Dentsply Tulsa Dental)

A

C

B

D

FE

Page 142: Ch10: ENDODONTIC CAVITY PREPARATION

3. Establish a smooth glide path with No. 10 and No.15 stainless steel hand files.

4. Use maximum magnification to observe the move-ment of the rotary instrument. “Seeing” rotary api-cal movement is safer than simply “feeling” suchmovement.

5. Use a torque- and speed-controlled electric motor,powering the handpiece at 200 to 300 rpm.

6. Be much gentler than with hand instruments.Always treat in a moist canal. Irrigate frequently!

7. Slow down! Each instrument should do minimalshaping. Only two, three, or four passes may berequired for the file to engage restrictive dentin andcarve the shape to the proper depth.

8. Instruments break when flutes become loaded orwhen instruments are forced. Check the flutes fre-quently under magnification and clean them. Cyclicfatigue from overuse, or if the glide path is not wellestablished, also leads to breakage.

9. ProTaper instruments are disposable and, like allendodontic files and reamers, are designed for sin-gle-patient use. Sometimes instruments are evenchanged within the same treatment (eg, in the caseof a four-canal molar).

10. Irrigate with 17% EDTA or a viscous chelator dur-ing the ProTaper shaping.

ProTaper System: Directions for Use

1. Establish proper access and a glide path with No. 10and No. 15 stainless steel files to the working lengthor the apical constriction exit.

2. Flood the canal and chamber with sodiumhypochlorite and begin shaping with the Shaper S-1using multiple, passive-pressure passes. Go no deep-er than three-quarters of the estimated canal length.Irrigate and recapitulate with a No. 10 hand file,establishing patency to full working length. Now,with S-1, extend the preparation to full workinglength. Again irrigate and recapitulate.

3. “Brush” with the Shaper S-X to improve thestraight-line access in short teeth or to relocate canalaccess away from furcations in posterior teeth.

4. Shaping file S-2 is now used to full working length.Irrigate, recapitulate, and reirrigate.

5. Confirm and maintain working length with a handfile. (Remember, as curves are straightened, canalsare shortened.)

6. With Finisher F-1, passively extend the preparationto within 0.5 mm of the working length. Withdrawafter one second! And only one second! The F-1 hasa tip size of 0.20 mm, and if a No. 20 hand instru-

546 Endodontics

ment is found to be snug, the preparation is finished.With the instrument in place, radiographically veri-fy the exact length before final irrigation.

7. If the F-1 and the No. 20 hand file are loose, contin-ue the preparation with the Finisher F-2, which is0.25 mm diameter at the tip. Confirm with a No. 25hand instrument and, if snug, confirm the lengthradiographically, irrigate, and complete.

8. If the F-2 instrument and the No. 25 hand file areloose, continue the preparation to just short of theworking length with the Finisher F-3 file, which hasa 0.30 mm tip diameter, and follow with the con-firming No. 30 instrument. If the No. 30 is found tobe snug, the preparation is finished (see Figure 10-89, D). If this is loose, there are a number of tech-niques to enlarge the apical third to larger sizes.

9. Frequent irrigation and file cleansing are impera-tive—irrigation and recapitulation!

Now that the perfectly tapered preparation is com-plete, smear layer removal with EDTA and sodiumhypochlorite is in order, followed by either medicationand/or obturation.

Quantec System and Graduating Taper Technique

The Quantec Series (Sybron Endo/Analytic; Orange,Calif.) consists of a series of 10 graduated nickel-titani-um tapers from 0.02 through 0.06 with ISO tip siz-ing507,518 (Figure 10-90). The Quantec Flare Series, withincreased tapers of 0.08, 0.10, and 0.12, all with tip sizesof ISO 25, are designed to quickly and safely shape thecoronal third of the canal. In contrast to the basic prin-ciples of other rotary instrument techniques, this systemincorporates a built-in “graduated tapers technique,”whereby a series of varying tapers are used to prepare asingle canal. The instruments are used at 300 to 350 rpmin a high-torque, gear-reduction, slow-speed handpiece.

Proponents of the graduating tapers techniqueclaim that, theoretically, using a series of files of a sin-gle taper, whether it is a conventional 0.02 taper or agreater taper, will result in decreased efficiency as larg-er instruments are used, that is, more of the file comesinto contact with the dentinal walls, making it moredifficult to remove dentin as forces are generated over alarger area.518 Ultimately, each instrument will becomefully engaged along the canal wall, potentially inhibit-ing proper cleaning and shaping of the apical canal.

In contrast and in accordance with the graduatingtapers technique, by restricting the surface contactbetween instrument and wall, an instrument’s efficien-cy is increased since the forces used are concentrated ona smaller area. In this technique, for example, once a

Page 143: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 547

0.02 taper has shaped the canal, a 0.03 taper with thesame apical diameter would engage the canal morecoronally; by altering the taper from 0.02, to 0.03, andup the scale to 0.06, the efficiency of canal preparationis maximized by restricting surface contact.

The Quantec rotary instruments are uniquely engi-neered with slightly positive rake or blade angles oneach of their twin flutes; these are designed to shaverather than scrape dentin (negative rake angle), whichmost conventional files do. Flute design also includes a30-degree helical angle with flute space that becomesprogressively larger distal to the cutting blade, helpingchannel the debris coronally. More peripheral mass hasbeen added to these files rather than depending on corestrength alone as in other rotary systems.

Quantec’s wide radial lands are purported to pre-vent crack formation in the blades and aid in deflectingthe instrument around curvatures. By recessing thewide radial lands behind the blade, there is a concomi-tant reduction in frictional resistance while maintain-ing canal centering.

With respect to tip geometry, the clinician has achoice of two designs. The SC safe-cutting tip (see Figure10-28, A) is specifically designed for small, tight canals,

narrow curvatures, and calcified canal systems. Thisfaceted 60-degree tip cuts as it moves apically; as the tipapproaches a curve, conceptually, a balance takes placebetween file deflection and cutting. The LX noncuttingtip, on the other hand, is a nonfaceted bullet-nosed tip,acting as a pilot in the canal and deflecting around severecurvatures in less constricted canals (see Figure 10-28,B). These LX Quantec instruments are also recommend-ed for enlarging the body and coronal segments andmanaging delicate apical regions.

Canal Preparation. The Graduating Tapers techniqueinvolves a modified step-down sequence, starting with alarger tapered file first and progressing with files of lessertaper until working length is achieved. The techniqueinvolves canal negotiation, canal shaping, and, finally, api-cal preparation. As in all instrumentation techniques,straight-line access to the canal orifices must be made first,followed by passive negotiation of the canal using No. 10and No. 15 0.02 taper hand files. A Quantec No. 25, 0.06taper, 17 mm in length, is passively used. In most cases, thisinstrument should approach the apical third of the canal;at this point, the working length must be established.

A “Glide Path” is now established for all subsequentQuantec files by working No. 10 and No. 15 0.02 taper

Figure 10-90 A, The Quantec series of variably tapered instruments comes in both safe-cutting (SC) and noncutting (LX) tips and threelengths: 17, 21, and 25 mm (see Figure 10-28). Quantec files are 30% shorter in the rotary “handle,” and when used in the Axxess Miniheadhandpiece, over 5 mm of length are saved. B, Cross-section of the newest Sybronendo rotary file-K3. Note that three cutting blades have pos-itive rakes that materially increase the cutting ability. Also note that the radial land relief reduces friction and provides debris collection space.The nickel-titanium files come in 0.04 and 0.06 tapers, tip sizes ISO 10 to 60, and increasing variable helical flute angle from D1 to D16.(Courtesy of SybronEndo.)

A B

Page 144: Ch10: ENDODONTIC CAVITY PREPARATION

hand files along with sodium hypochlorite to the estab-lished working length. During the shaping phase, eachQuantec file, progressing sequentially from a 0.12 taperdown to a 0.03 taper, is passively carried into the canal asfar as possible. In all cases, light apical pressure must beapplied, using a light pecking motion and never advanc-ing more than 1 mm per second into the canal. Eachinstrument should be used for no more than 3 to 5 sec-onds. The sequence is repeated until a 0.06 or 0.05 taperreaches the working length. The apical preparation canthen be deemed complete or further enlarged by usingthe Quantec standard 0.02 taper No. 40 or No. 45 rotaryinstruments or hand files.

With the Quantec series, the correct amount of api-cal pressure must be maintained at all times; the con-tinuously rotating instrument should either be insertedor withdrawn from the canal while allowing for its slowapical progression. The instrument, however, should bewithdrawn after the desired depth has been reachedand not left in the canal for an extended period of time,potentially causing canal transportation, ledge forma-tion, and instrument separation. Thus, to reduce pro-cedural problems, there should always be a continuousapical/coronal movement of the instrument, and, if therotating file begins to make a clicking sound (file bind-ing), one should withdraw the file and observe forinstrument distortion.

LightSpeed Endodontic Instruments

The LightSpeed rotary instrumentation system(LightSpeed Technology; San Antonio, Tex.), so namedbecause of the “light” touch needed as the “speed” ofinstrumentation” is increased, involves the use of spe-cially engineered nickel-titanium “Gates-Glidden-like”reamers (see Figure 10-90) that allow for enhanced tac-tile control and apical preparations larger than thosecreated via conventional techniques and other nickel-titanium rotary systems.502,508,514,519–521 The set ofinstruments consists of ISO-sized rotary files from size20 through 100, including nine half-sizes ranging from22.5 through 65. The half sizes help reduce stress onboth the instrument and root during preparation anddecrease the amount of cutting that each instrumentmust accomplish. In most clinical cases, about 8 to 14instruments are needed. They are used in a continuous,360-degree clockwise rotation with very light apicalpressure in a slow-speed handpiece. The recommendedrpm is between 750 and 2,000, with preference towardthe 1,300 to 2,000 range.

Owing to the flexible, slender, parallel shaft (Figure10-91) that makes up the body of the instrument, the cli-nician can prepare the apical portion of the canal with

548 Endodontics

the “head” of the LightSpeed to a size larger than whatcould normally be produced using tapered instruments.Since taper adds metal and decreases both flexibility andtactile feel toward the more apical regions of the canal,the LightSpeed instrument head, with its short cuttingblades, only binds at its tip, thus increasing the accuracyof the tactile feedback. This results in rounder and cen-tered apical preparations.502,508,514,519–521 Success withthe LightSpeed, however, is predicated on straight-lineaccess, an adequate coronal preflare, and establishmentof working length prior to its introduction into a canal.

The LightSpeed instrument has a short cutting bladewith three flat radial lands, which keeps the instrumentfrom screwing into the canal, a noncutting pilot tip (seeFigures 10-90 inset, and Figure 10-26), and a small-diameter noncutting flexible shaft, which is smallerthan the blade and eliminates contact with the canalwall. Laser-etched length control rings on the shafteliminate the need for silicone stops (see Figure 10-90).The LightSpeed instrument has a cross-sectional U-blade design in which flat radial lands with neutral rakeangles enhance planing of the canal walls and centeringof the instrument within the canal. The helical bladeangle and narrow shaft diameter facilitate debrisremoval coronally.

Canal Preparation. Following proper coronal access,preflaring with Gates-Glidden drills or another methodis highly recommended. The working length must first beestablished with at least a No. 15 stainless steel K file.Prior to using the LightSpeed in the handpiece, the clini-cian should first select and hand-fit a No. 20 LightSpeedinstrument that binds short of the working length. Once

Figure 10-91 LightSpeed instrument. The head has a noncuttingtip and is the U-style design. Note the small cutting head and thelong noncontacting shaft, making the LightSpeed a unique instru-ment, much like a Gates-Glidden in configuration. (Courtesy ofLightSpeed Technology.)

Page 145: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 549

fitted, that LightSpeed instrument is now inserted in thegear-reduction, slow-speed handpiece. The LightSpeedmust enter and exit the canal at the proper rpm, prefer-ably 1,300 to 2,000 rpm for smoother and faster instru-mentation.520 As with other systems, the rpm must bekept constant to avoid abrupt changes that may result inloss of tactile feedback and instrument breakage.

There are two recommended motions withLightSpeed: (1) if no resistance is felt, the LightSpeed isgently advanced to the desired length and withdrawn,or (2) if resistance is felt, a very light apical peckingmotion (advance and withdraw motion) should beused until working length is attained. In either case, theinstrument should never stay in one place as thisincreases transportation and enhances separation. Thisgentle pecking motion prevents blade locking, removesdebris coronally, and aids in keeping the blades clean.

Increasingly larger LightSpeed instruments are used tothe working length, never skipping sizes, including thehalf-sizes. Irrigation should occur at least once after everythree instruments. Once the apical stop has been estab-lished, the LightSpeed should never be forced beyond thispoint. If forced, buckling along the shaft may occur,potentially leading to fatigue and instrument separation.

The MAR, or Master Apical Rotary (the smallestLightSpeed size to reach the working length, yet largeenough to clean the apical part of the canal), becomes thesubsequent instrument that first binds 3 to 4 mm short ofthe working length. This instrument will require 12 to 16pecks (ie, 4 pecks per millimeter advancement) to reachthe working length. This MAR, typically larger than thesize achieved with most other methods, has been shownto clean the sides of the canal while remaining centeredand creating a round preparation.502,508,519–521

The apical 4 mm of the canal are shaped usingsequentially larger instruments in step-back sequencewith 1 mm intervals. The remainder of the step-back isdone by feel. Finally, the last instrument taken to fullworking length is used for recapitulation. The taper ofa canal prepared with LightSpeed is approximately0.025 mm/mm to preserve tooth structure. To preventinstrument separation from torsional overload or frombuckling along the shaft (cyclic or bending fatigue),LightSpeed instruments must always be used with lightapical pressure—never forced.514 If the blade breaksoff, it frequently can be bypassed.

Rapid Body Shapers, Rotary Reamers, and Pow-RRotary Files

Rapid Body Shaper (RBS) (Moyco/Union Broach;Bethpage, N.Y.) consists of a series of four nickel-tita-nium rotary engine reamers (Figure 10-92). These

instruments feature the patented nonledging Roanebullet tip and allow the practitioner to rapidly shapethe body of the canal without the problems that canoccur using Gates-Glidden drills. The RBS instrumentsdevelop a parallel-walled canal shape. The RBS seriesconsists of four instruments: No. 1 (0.61 mm at thetip), No. 2 (0.66 mm at the tip), No. 3 (0.76 mm at thetip), and No. 4 (0.86 mm at the tip).

Canal Preparation. Prior to using RBS, the apicalregion of the canal must be prepared with a minimumNo. 35 ISO instrument to within 0.5 mm of the apex. TheNo. 1 RBS is then placed in a gear-reduction, slow-speedhandpiece at 275 to 300 rpm and allowed to track downthe canal 2 to 3 mm. Constant and copious irrigation isnecessary at all times. The RBS is removed to clean thefluting and is reinserted to track another 2 to 3 mm downthe canal. This sequence is repeated until the No. 1 RBS iswithin 4 mm of the apex. The No. 2 RBS is then used likethe No. 1, also to within 4 mm or shorter from the apex.The No. 3 RBS, followed by the No. 4 RBS, is used towithin 7 mm of the apex, completing the body shaping.The No. 1 RBS will feel very aggressive, whereas the No. 2through 4 RBS feel almost passive in comparison. Apicalrefinement is subsequently completed by hand instru-ments or via Pow-R nickel-titanium rotary instruments.

Pow-R Nickel-Titanium Rotary Files (Moyco/UnionBroach; Bethpage, N.Y.), also with a nonledging Roanebullet tip, are available in both 0.02 and 0.04 tapersand, owing to their taper design, allow the practitionerto clean and shape the middle and apical regions of thecanal in a conservative manner. These instrumentscome in standard ISO instrument sizes as well as in halfsizes 17.5, 22.5, 27.5, 32.5, and 37.5 for more preciseapical refinement. They follow standard ISO colorcodes as well.

Figure 10-92 Series of four Rapid Body Shapers. From the top tothe bottom, Nos. 1, 2, 3, and 4. (Courtesy of Moyco/Union Broach.)

Page 146: Ch10: ENDODONTIC CAVITY PREPARATION

Canal Preparation. Once Gates-Glidden drills areused to prepare and shape the coronal region of thecanal in a step-down manner, and the canal has been atleast partially negotiated with hand files, Pow-R filescan be used. The clinician should select a file that bindsat its tip in the middle third and begin to graduallymove and push that file as it is rotating, slightly with-drawing it every 0.25 mm penetration until no morethan 2 mm of depth are achieved or until resistance isfelt. Like any other nickel-titanium file, these instru-ments must be used passively and with a light touch orpecking motion. The working length should now bedetermined using a hand file. Constant recapitulationwith hand files is the rule along with constant irriga-tion. The next smaller Pow-R file is used to continueshaping an additional 1 to 2 mm deeper. Rotary instru-mentation continues, decreasing sizes in sequenceuntil the shaping is about 1.5 mm short of the apicalforamen. The remaining portion of the canal can befinished with hand instruments or with Pow-R files. Ifmore flare is needed, particularly if an obturation tech-nique that requires deep condenser penetration is con-sidered, a rotary incremental step-back can be used togenerate additional space in the apical and middle por-tions of the canal.

Both the RBS files and Pow-R instruments are usedin high-torque, gear-reduction handpieces with rpmranging from 300 to 400.

Principles of Nickel-Titanium RotaryInstrumentation

Irrespective of the nickel-titanium system used, nickel-titanium instruments are not designed for pathfinding,negotiating small calcified or curved canals, or bypass-ing ledges. Placing undue pressure on these extremelyflexible instruments may lead to file breakage. This isattributable to the fact that nickel-titanium has lesslongitudinal strength and may deflect at a point wherepressure is off the file. As mentioned throughout thissection, stainless steel instruments should be used ini-tially for pathfinding owing to their enhanced stiffness.Once the canal has been negotiated with at least a stain-less steel No. 15 K-type file or a ledge has been bypassedand removed, then rotary nickel-titanium instrumentscan be used. Stainless steel instruments are also moreradiopaque than nickel-titanium and “show up” betterin tooth length measurements.

When using a gear-reduction, slow-speed, nickel-titanium rotary handpiece, the clinician must alwayskeep the handpiece head aligned with the long axis ofeach canal as good straight-line access decreases exces-sive bending on the instrument. Nickel-titanium rotary

550 Endodontics

instruments must be used with light apical pressureand never be forced and must always be used in alubricated canal system to reduce frictional resistance,preferably with RC-Prep or Glyde or another accept-able lubricant.

Abrupt curvatures, S-shaped canal systems, andcanals that join must be avoided with any nickel-titani-um rotary file; use of rotary files in these cases may alsolead to breakage. When a nickel-titanium file rotatesinside any canal system, it becomes stressed and maysubsequently “wobble” in the handpiece once theinstrument is removed; the file should be disposed of.As the nickel-titanium file experiences any unduestress, including cyclic fatigue,514 the metal undergoes acrystalline (microscopic) phase transformation andcan become structurally weaker. In many cases, there isusually no visible or macroscopic indication that themetal has fatigued. With repeated sterilization,Rapisarda et al. demonstrated decreased cutting effi-ciency and alteration of the superficial structure ofNickel-titanium ProFiles, thus indicating a weakenedstructure, possibly prone to fracture.522 Essentially, anickel-titanium file may disarticulate without anywarning, especially if not properly used. Thus, itbehooves the astute clinician to develop a systematicmethod for recognizing potential problems (grabbingor frictional locking of files into the canal, unwinding,twisting, cyclic fatigue, etc) and disposing of thesenickel-titanium instruments. No one knows the maxi-mum or ideal number of times that a nickel-titaniumfile can be used.

There is no doubt that the evolution of mechanizedor rotary instrumentation using specially designednickel-titanium files in gear-reduction, high-torquehandpieces has revolutionized endodontics owing totheir speed and efficacy in canal shaping and maintain-ing canal curvature. There is also no doubt that thedevelopment of the shape-memory alloy, nickel titani-um, for use in endodontics has elevated the practice ofendodontics to a higher level. With the evolution oftorque-control electric motors and the continual engi-neering of more sophisticated instrument designs,cleaning and shaping with rotary instruments, madewith shape-memory alloys, may eventually become thestandard of care.

LASER-ASSISTED CANAL PREPARATION

After the development of the ruby laser by Maiman in1960, Stern and Sognnaes (1964) were the first investi-gators to look at the effects of ruby laser irradiation onhard dental tissues.523 Early studies of the effects oflasers on hard dental tissues were based simply on the

Page 147: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 551

empirical use of available lasers and an examination ofthe tissue modified by various techniques.

Laser stands for Light Amplification by StimulatedEmission of Radiation, and it is characterized by beingmonochromatic (one color/one wavelength), coher-ent, and unidirectional. These are specific qualitiesthat differentiate the laser light from, say, an incandes-cent light bulb.

For any procedures using lasers, the optical interac-tions between the laser and the tissue must be thor-oughly understood to ensure safe and effective treat-ment. The laser-light interaction is controlled by theirradiation parameters, that is, the wavelength, therepetition rate, the pulse energy of the laser, as well asthe optical properties of the tissue. Typically, opticalproperties are characterized by the refraction index,scattering (µs), and absorption coefficients (µa).However, the ultimate effects of laser irradiation ondental tissue depend on the distribution of energydeposited inside the tooth. Laser energy must beabsorbed by tissue to produce an effect. The tempera-ture rise is the fundamental effect determining theextent of changes in the morphology and chemicalstructure of the irradiated tissue.524

Lasers emitting in the ultraviolet, visible (ie, argonlaser—488 and 514 nm), and near infrared (ie,neodymium:yttrium-aluminum-garnet [Nd:YAG]laser—1.064 µm) are weakly absorbed by dental hardtissue, such as enamel and dentin, and light scatteringplays a very important role in determining the energydistribution in the tissue. Nd:YAG laser energy, on theother hand, interacts well with dark tissues and istransmitted by water. Argon lasers are more effective onpigmented or highly vascular tissues.

Excimer lasers (193, 248, and 308 nm) and theerbium laser (~3.0 µm) are strongly absorbed by den-tal hard tissues. Neev et al. have shown that the excimerat 308 nm is efficiently absorbed by dentin since itoverlaps protein absorption bands.525,526 The erbiumlaser emits in the mid-infrared, which coincides withone of the peaks of absorption of water and the OH- ofhydroxyapatite. Because of that, this laser is stronglyabsorbed by water, the absorbed energy induces a rapidrise in temperature and pressure, and the heated mate-rial is explosively removed.

The carbon-dioxide lasers emitting in the far infrared(10.6 µm) were among the first used experimentally forthe ablation of dental hard tissues. The carbon-dioxidelaser is the most effective on tissues with high water con-tent and is also well absorbed by hydroxyapatite.

Studies have been conducted evaluating the effectsof laser irradiation inside root canals. The authors have

discussed laser-endodontic therapy, some as supple-mentary and others as a purely laser-assistedmethod.527 Although the erbium:YAG (May 1997) anderbium:YSGG (October 1998) lasers were approved fordental hard tissues, lasers still need to be approved bythe US Food and Drug Administration (FDA)Committee on Devices for intracanal irradiation. TheFDA’s clearance for these devices includes cariesremoval and cavity preparation, as well as rougheningenamel. Other countries, such as Germany, Japan, andBrazil, have been conducting basic research and laserclinical trials, and some of the devices have been usedthere for treatment.

Laser Endodontics

In 1971, at the University of Southern California,Weichman and Johnson were probably the firstresearchers to suggest the use of lasers in endodontics.528

A preliminary study was undertaken to attempt to ret-roseal the apical orifice of the root canal using anNd:YAG and a carbon-dioxide laser. Although the goalwas not achieved, relevant data were obtained. In 1972,Weichman et al. suggested the occurrence of chemicaland physical changes of irradiated dentin.529 The samelaser wavelengths were then used, with different materi-als, in an attempt to seal internally the apical constriction.

Applications of lasers in endodontic therapy havebeen aggressively investigated over the last two decades.According to Stabholz of Israel, there are three mainareas in endodontics for the use of lasers: (1) the peria-pex, (2) the root canal system, and (3) hard tissue,mainly the dentin.530 One of the major concerns ofendodontic therapy is to extensively clean the root canalto achieve necrotic tissue débridement and disinfection.In this sense, lasers are being used as a coadjuvant toolin endodontic therapy, for bacterial reduction, and tomodify the root canal surface. The action of differenttypes of laser irradiation on dental root canals—the car-bon-dioxide laser,531 the Nd:YAG laser,532 the argonlaser,533 the excimer laser,534 the holmium:YAG laser,535

the diode laser,536 and, more recently, the erbium:YAGlaser537—has been investigated.

Unlike the carbon-dioxide laser, the Nd:YAG (Figure10-93, A), argon, excimer, holmium, and erbium laserbeams can be delivered through an optical fiber (Figure10-93, B) that allows for better accessibility to differentareas and structures in the oral cavity,530 including rootcanals. The technique requires widening the root canalby conventional methods before the laser probe can beplaced in the canal. The fiber’s diameter, used inside thecanal space, ranges from 200 to 400 µm, equivalent to aNo. 20-40 file (Figure 10-93, C).

Page 148: Ch10: ENDODONTIC CAVITY PREPARATION

Dederich et al., in 1984, used an Nd:YAG laser toirradiate the root canal walls and showed melted,recrystalized, and glazed surfaces.527 Bahcall et al., in1992, investigated the use of the pulsed Nd:YAG laser tocleanse root canals.538 Their results showed that theNd:YAG laser may cause harm to the bone and peri-odontal tissues—a good example that laser parametersshould constitute one of the factors for safety and effi-cacy of laser treatment.

According to Levy532 and Goodis et al.,539 theNd:YAG, in combination with hand filing, is able toproduce a cleaner root canal with a general absence ofsmear layer. The sealing depth of 4 µm produced by theNd:YAG laser was reported by Liu et al.540

One concern for laser safety is the heat produced atthe irradiated root surface that may cause damage tosurrounding supporting tissue. Studies evaluatingchanges at the apical constriction and histopathologicanalysis of the periapical tissues were presented byKoba and associates.541,542 They maintained the fiber

552 Endodontics

optic at a stationary point, 1 mm from the apical fora-men, for 2 to 3 seconds. Infiltration of inflammatorycells was observed in all groups in 2 weeks, includingthe control group. Indeed, the degree of inflammationreported in the laser-irradiated group at 2 weeks, 30 Hz(0.67 mJ/p) for 2 seconds, was significantly less than inthe control group at 4 and 8 weeks. However, the sameauthors have shown542 that carbonization wasobserved in irradiated root canals depending on theparameter used. A technique considered optimal byGutknecht et al. would be the irradiation from apical tocoronal surface in a continuous, circling fashion.543

Different laser “initiators” (dyes to increase absorp-tion) with the Nd:YAG laser were tested by Zhang etal.544 Black ink was an effective initiator for this laser,but the root canal was inconsistently changed. It mightbe a consequence of the lack of uniformity in the distri-bution of the ink or laser irradiation inside the canals.

Under the scanning electron microscope (SEM),lased dentin showed different levels of canal débride-

Figure 10-93 A, Nd:YAG (1.06 µm) laser device delivered by a quartz fiber optic—200, 300, 320, and 400 µm diameter fiber available. B,Endo fiber (arrow) (285 and 375 µm fiber available) and handpiece for the erbium:YAG laser. C, Radiograph of canine tooth withErbium:YAG fiber introduced into the root canal. (Courtesy of American Dental Technologies; Corpus Christi, Tex.)

A

B

C

Page 149: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 553

ment, including smear layer removal and morphologicchanges, related to the energy level and repetition rateused.545 There was no indication of cracking in all ofthe SEM samples at these laser parameters. Theerbium:YAG laser, at 80 mJ, 10 Hz, was more effectivefor debris removal (Figure 10-94, A), producing acleaner surface with a higher number of open tubuleswhen compared with the other laser treatment and thecontrol—without laser treatment (Figure 10-94, B). Adecreased level was observed when the energy wasreduced from 80 to 40 mJ. Nd:YAG laser-irradiatedsamples presented melted and recrystalized dentin andsmear layer removal (Figure 10-94, C).

The root canal walls irradiated by the erbium:YAGlaser were free of debris, the smear layer was removed,and the dentinal tubules were opened, as recentlyreported by Takeda et al.546,547 and Harashima et al.,548

although areas covered by residual debris could befound where the laser light did not enter into contactwith the root canal surface.548 Scanning electronmicroscopic evaluation showed different patterns as aresult of the different mechanisms of laser-tissue inter-action by these two wavelengths.546–548

According to Hibst et al., the use of a highlyabsorbed laser light, like the erbium laser, tends tolocalize heating to a thin layer at the sample surface,thus minimizing the absorption depth.549 There fol-

lows a decrease in the risk of subsurface thermal dam-age since less energy is necessary to heat the surface.

The efficacy of argon laser irradiation in removingdebris from the root canal system was evaluated byMoshonov et al.533 After cleaning and shaping, a 300 µmfiber optic was introduced into the root canals of single-rooted teeth to their working length. During irradiation,the fiber was then retrieved, from the apex to the orifice.Scanning electron microscopic analysis revealed that sig-nificantly more debris was removed from the lasedgroup than from the control (Figure 10-95).

Although it appears that argon laser irradiation ofthe root canal system efficiently removes intracanaldebris, its use as a treatment modality in endodonticsrequires further investigation. This is partially truebecause this laser is emitted in a continuous mode—like the carbon-dioxide laser—in the range of millisec-onds. This means that a longer period of interactionwith the intracanal surface is required and, conse-quently, a great increase in temperature.

One of the limitations of the laser treatment wasdemonstrated by Harashima et al.550 Where the(argon) laser optic fiber had not touched or reachedthe canal walls, areas with clean root canal surfaceswere interspersed with areas covered by residualdebris. Access into severely curved roots and the cost ofthe equipment are other limitations.

Figure 10-94 Intracanal dentin surfaces (apical third)under SEM–1500X- laser parameters: A, Dentin surfacelased with erbium:YAG 100 mJ and 15 Hz. Effectivedebris removal. B, Control; unlased dentin surface. C,Nd:YAG reduced to 80 mJ and 10 Hz. Note melted andrecrystalized dentin surface. Reproduced with permis-sion from Cecchini SCM et al.545

A B

C

Page 150: Ch10: ENDODONTIC CAVITY PREPARATION

The Future

Wavelengths emitted at the ultraviolet portion of theelectromagnetic spectrum appear to be promising inendodontics. ArF excimer laser at 193 nm is well suit-ed to slow selective removal of necrotic debris fromthe root canal, leaving behind smooth, crack-free andfissure-free, melted dentin walls (P Wilder-Smith, per-sonal communication, July 26, 1993). The XeCl (308nm) excimer laser was capable of melting and closingdentinal tubules in a study performed by Stabholz andcolleagues.551

Very short pulses (15 ns) will avoid significant heataccumulation in the irradiated tooth. When higher-energy densities were used (4 J/cm2), however, ruptureof the molten materials and exposure of the tubuleswere noted. No clinical results are presently available.The second harmonic alexandrite laser (377 nm/ultra-violet), in development by Hennig and colleagues inGermany, has been shown to selectively remove dentalcalculus and caries and appears to be very promisingfor bacterial reduction, as well as for future applicationin periodontics and endodontics.552

Indeed, the ability of certain lasers to ablate necrot-ic organic materials and tissue remnants and reducemicroorganisms seems highly promising in endodon-tics. A significant reason for using laser intracanal irra-diation is the microbial reduction, usually achieved bytemperature rise. Several studies have evaluated theeffectiveness of lasers in sterilizing root canals and havereported significant in vitro decreases in number ofbacteria.537,553–557 However, the performance of thisequipment, concerning safe and effective wavelengthand energy levels related to temperature rise, morpho-

554 Endodontics

logic changes, and microbial reduction, should be welldocumented before it becomes a current method oftreatment.

It is important to realize that different types of lasershave different effects on the same tissue, and the samelaser will interact differently depending on the types oftissue. Safety precautions used during laser irradiationinclude safety glasses specific for each wavelength(compatible optical density to filtrate that wavelength),warning signs, and high-volume evacuation close tothe treated area (used in soft tissue procedures, cavitypreparation, etc).

Noninstrumentation Root Canal Cleansing

Based on the premise that “[O]ptimal cleansing of theroot canal system is a prime prerequisite for long termsuccess in endodontics,” Lussi and his associates at theUniversity of Bern, Switzerland, introduced devices tocleanse the root canal “without the need of endodonticinstrumentation.”558 The first device, reported in 1993,consisted of a “pump” that inserted an irrigant into thecanal, creating “bubbles” and cavitation that loosenedthe debris. This pressure action was followed by a neg-ative pressure (suction) that removed the debris: “Theirrigant fluid was injected through the outer tube whilethe reflux occurred through the inner tube.” Morerecently, they have improved the device and reportedthat the “smaller new machine produced equivalent orbetter cleanliness results in the root canal system usingsignificantly less irrigant (NaOCl).”559 This cleanses thecanal but, of course, does nothing to shape the canal(Figure 10-96).

PULPECTOMY

Rather than break into the flow of detailing the meth-ods of cleaning and shaping the root canal, we havereserved until now the often necessary task of remov-ing a vital pulp, diseased though it may be. This istermed pulp extirpation or pulpectomy. Total pulpec-tomy, extirpation of the pulp to or near the apicalforamen, is indicated when the root apex is fullyformed and the foramen sufficiently closed to permitobturation with conventional filling materials. If thepulp must be removed from a tooth with an incom-pletely formed root and an open apex, partial pulpec-tomy is preferred. This technique leaves the apical por-tion of pulp intact with the hope that the remainingstump will encourage completion of the apex (Figure10-97). The necrotic or “mummified” tissue remainingin the pulp cavity of a pulpless tooth has lost its iden-tify as an organ; hence, its removal is called pulp cavi-ty débridement.

Figure 10-95 Effect of argon laser on intracanal debris. Mean andstandard deviation of overall cleanliness of root canal wall surfacesin lased and nonlased specimens. Reproduced with permissionfrom Moshonov J et al.533

Page 151: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 555

Indications

Pulp “mummification” with arsenic trioxide, formalde-hyde, or other destructive compounds was at one timepreferable to extirpation.560 With the advent of effec-tive local anesthetics, pulpectomy has become a rela-tively painless process and superseded “mummifica-tion,” with its attendant hazards of bone necrosis andprolonged postoperative pain.

Pulpectomy is indicated in all cases of irreversiblepulp disease. With pulpectomy, dramatic relief isobtained in cases of acute pulpitis resulting from infec-tion, injury, or operative trauma. Pulpectomy is usual-ly the treatment of choice when carious or mechanicalexposure has occurred. In a number of instances,restorative and fixed prosthetic procedures requireintentional extirpation.561

Technique

The following are the steps in the performance of awell-executed pulpectomy:

1. Obtain regional anesthesia.2. Prepare a minimal coronal opening and, with a

sharp explorer, test the pulp for depth of anesthesia.3. If necessary, inject anesthetic intrapulpally.

Figure 10-96 A, Root canal cleansed for 10 minutes with the newminiaturized hydrodynamic turbulence device using 3% sodiumhypochlorite. Tiny residual fragment of pulp tissue remains at theapex of one canal. B, Photomicrograph shows calcospherites andopen dentinal tubules, but no smear layer that develops with instru-mentation. Reproduced with permission from Lussi A et al.559

Figure 10-97 Partial pulpectomy. Observation period of 6months. Only slight accumulation of lymphocytes adjacent to aplug of dentin particles and remnants of Kloropercha (DF at top).Cell-rich fibrous connective tissue occupies the residual pulp canal.Large deposits of hard tissue (H) along walls. Reproduced with per-mission from Horstad P, Nygaard-Østby B. Oral Surg 1978;46:275.

A

B

Page 152: Ch10: ENDODONTIC CAVITY PREPARATION

4. Complete the access cavity.5. Excavate the coronal pulp.6. Extirpate the radicular pulp.7. Control bleeding and débride and shape the canal.8. Place medication or the final filling.

Each of these steps must be completed carefully beforethe next is begun, and each requires some explanation.

Profound Anesthesia

Methods for obtaining profound infiltration and con-duction anesthesia have been considered earlier (chap-ter 9). One aspect of the subject deserves repetition: itsunusual importance in endodontics! From the erawhen pulps were extirpated by driving wooden pegs,red-hot wires, or crude broaches into the living tissueswithout benefit of anesthesia,562 there has persisted aprofound and widespread dread of “having a ‘nerve’taken out of a tooth.” The popular misconception thatendodontic treatment invariably involves suffering willnot be completely dispelled until all practitionersemploy effective anesthesia techniques while complet-ing procedures as potentially painful as pulpectomy.

Minimal Coronal Opening and Intrapulpal Anesthesia

It is wise to anticipate that, in spite of apparently pro-found anesthesia, an intraligamentary or intrapulpalinjection may be required to obtain total anesthesia,particularly with an inflamed pulp. If the patient expe-riences pain during the initial stage of access prepara-tion, there is no question that manipulation of the pulpwill be a painful process. The success of the intrapulpalinjection will be ensured if the initial penetration of thepulp chamber is made with a sharp explorer close tothe size of the injection needle. Since the needle fits thesmall opening tightly, the anesthetic can be forced intothe pulp under pressure. Total anesthesia followsimmediately (for greater detail, see chapter 9).

Completion of the Access Preparation

Coronal access must be adequate and complete to allowthorough excavation of the tissue from the pulp cham-ber. Because intrapulpal injection with 2% lidocainewith 1:50,000 epinephrine promotes excellent hemo-stasis, it can be used during the completion of theaccess cavity to prevent interference from hemorrhag-ing tissue.

Excavation of the Coronal Pulp

All of the tissue in the pulp chamber should beremoved before extirpation of the radicular pulp is

556 Endodontics

begun. All pulp tissue that has not been removed by theround bur should be eliminated with a sharp spoonexcavator. The tissue is carefully curetted from the pulphorns and other ramifications of the chamber. Failureto remove all tissue fragments from the pulp chambermay result in later discoloration of the tooth. At thispoint, the chamber should be irrigated well to removeblood and debris.

Extirpation of Radicular Pulp

The instrument used for this procedure is determinedby the size of the canal and/or the level at which thepulp is to be excised.

Large Canal, Total Pulpectomy

If the canal is large enough to admit a barbed broach(Figure 10-98, A) and a total pulpectomy is desired, theapproach is as follows:

1. A pathway for the broach to follow is created by slid-ing a reamer, file, or pathfinder along the wall of thecanal to the apical third. If the pulp is sensitive orbleeding, the anesthetic syringe needle may be usedas the “pathfinder.” A drop of anesthetic deposited

Figure 10-98 A, Total pulpectomy accomplished with a largebarbed broach that fits loosely in the canal. With careful rotation ofthe broach, the pulp has become entwined and will be removed onretraction. B, Total pulpectomy by a barbed broach. Young, hugepulps may require two or three broaches inserted simultaneously tosuccessfully entwine pulp.

A B

Page 153: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 557

near the apical foramen will stop the flow of bloodand all pain sensations. At the same time, the needledisplaces the pulp tissue and creates the desiredpathway for a broach.

2. A broach, small enough not to bind in the canal, ispassed to a point just short of the apex. The instru-ment is rotated slowly, to engage the fibrous tissue inthe barbs of the broach, and then slowly withdrawn.Hopefully, the entire pulp will be removed with thebroach (Figure 10-98, B). If not, the process isrepeated. If the canal is large, it may be necessary toinsert two or three broaches simultaneously toentwine the pulp on a sufficient number of barbs toensure its intact removal.

3. If the pulp is not removed intact, small broaches areused to “scrub” the canal walls from the apex outwardto remove adherent fragments. A word of caution:The barbed broach is a friable instrument and mustnever be locked into the canal. Handle with care!

Small Canal, Total Pulpectomy

If the canal is slender, and a total pulpectomy is indi-cated, extirpation becomes part of canal preparation. Abroach need not be used. Small files are preferred forthe initial instrumentation because they cut morequickly than reamers. In such a canal, Phase I instru-mentation to a No. 25 file is usually minimal to removethe apical pulp tissue (Figure 10-99). New rotaryincreased-tapered instruments open up the coronal

third of the canal, allowing for more efficient removalof the pulp.

Partial Pulpectomy

When a partial pulpectomy is planned, a techniquedescribed by Nygaard-Østby (personal communica-tion, 1963) is employed. From a good radiograph, thewidth of the canal at the desired level of extirpation isdetermined. A Hedstroem file of correct size is blunt-ed so that the flattened tip will bind in the canal at thepredetermined point of severance. The Hedstroem filehas deep fluting and makes a cleaner incision thanother intracanal instruments. Enlargement of thecanal coronal portion is then carried out with a seriesof larger instruments trimmed to the same length.

Neither Stromberg563 nor Pitt Ford564 was particu-larly enthusiastic about healing following pulpectomy,either total or partial. Working with dogs, both weretroubled by postoperative periradicular infections pos-sibly induced by coronal microleakage. Pitt Ford con-sidered anachoresis the route of bacterial contamina-tion. Others have found, however, that intracanal infec-tions by anachoresis do not occur unless the periradic-ular tissues were traumatized with a file and bleedingwas induced into the canal.565

Control of Bleeding and Débridement of Canal

Incomplete pulpectomy will leave in the canal frag-ments of tissue that may remain vital if their blood

Figure 10-99 A, Space between canal walls and No. 10 file demonstrates need to instrument the canal to at least file size No. 25 for totalpulpectomy. B, No. 25 instrument engaging walls and removing pulp. (Courtesy of Dr. Thomas P. Mullaney.)

BA

Page 154: Ch10: ENDODONTIC CAVITY PREPARATION

supply is maintained through accessory foramina oralong deep fissures in the canal walls (Figure 10-100).These remnants of the pulp may be a source of severepain to the patient, who will return seeking relief assoon as the anesthesia wears off. This is a desperatelypainful condition and requires immediate reanestheti-zation and extirpation of all tissue shreds. Any over-looked tissue will also interfere with proper obturationduring immediate filling procedures.

Persistent bleeding following extirpation is usually asign that “tags” of pulp tissue remain. If the flow ofblood is not stopped by scrubbing the canal walls witha broach, as described above, it may originate in theperiradicular area. In these cases, it is best to dry thecanal as much as possible after irrigating with anes-thetic. A dry cotton pellet is then sealed in until a sub-sequent appointment.

Emergency Pulpotomy

Although complete pulpectomy is the ideal treatmentfor an irreversibly inflamed vital pulp requiring

558 Endodontics

endodontic therapy, a temporary pulpotomy can beperformed in a relatively short period of time. In a busypractice, where it may not be practical to completeinstrumentation at the emergency visit, a pulpotomycan be done. First, anesthetic solution is used to irrigatethe pulp chamber. The coronal pulp is then amputatedwith a sharp excavator. A well-blotted Formocresol pel-let may be sealed in with a suitable temporary. Someadvocate sealing in cotton alone, with no medication.The temporary pulpotomy will normally provide thepatient with relief until complete instrumentation canbe carried out at a subsequent appointment. Swedishdentists used this technique in 73 teeth with irre-versible pulpitis and arrested toothache 96% of thetime. Three patients, however, had to return for totalpulpectomy for pain relief.566

Placement of Medication or Root Canal Filling

If pulpectomy was necessitated by pulpitis resultingfrom operative or accidental trauma, or plannedextirpation of a normal pulp for restorative purposeswas done, cleaning and shaping and obturation ofthe canal can be completed immediately. If a delay isnecessary, a drug of choice or dry cotton should besealed in the chamber. The final canal filling shouldnever be placed, however, unless all pulpal shreds areremoved and hemorrhage has stopped. Immediatefilling is contraindicated if the possibility of pulpalinfection exists.

INTRACANAL MEDICATION

Antibacterial agents such as calcium hydroxide are rec-ommended for use in the root canal between appoint-ments. While recognizing the fact that most irrigatingagents destroy significant numbers of bacteria duringcanal débridement, it is still thought good form to fur-ther attempt canal sterilization between appointments.The drugs recommended and technique used are thor-oughly explored in chapter 3.

IATRAL ERRORS IN ENDODONTIC CAVITY PREPARATION

For a description of the prevention and correction of mishaps in endodontic cavity preparations, seechapter 15.

REFERENCES

1. Black GV. Operative dentistry. 7th ed. Vol II. Chicago:Medico-Dental Publishing; 1936.

2. Kobayashi C, Yoshioka T, Suda H. A new engine-driven canalpreparation system with electronic canal measuring capa-bility. JOE 1997;23:75.

3. Stokes AN, Tidmarsh BG. A comparison of diamond and

Figure 10-100 A, C-shaped canal in mandibular molar. B, Onecan imagine the severe difficulty encountered in attempting tototally remove all pulp tissue from such an aberrant canal system.(Courtesy of Dr. L. Stephen Buchanan.)

Page 155: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 559

tungsten carbide burs for preparing endodontic access cav-ities through crowns. JOE 1988;14:550.

4. Teplitsky PE, Sutherland JK. Endodontic access openingsthrough Cerestore crowns [abstract]. JOE 1985;10.

5. Cohen BD, Wallace JA. Castable glass ceramic crowns and theirreaction to endodontic therapy. Oral Surg 1991;72:108.

6. Pucci FM, Reig R. Conductos radiculares. Vol II. Buenos Aires:Editorial Medico-Quirurgica; 1944.

7. Reeh ES, et al. Reduction in tooth stiffness as a result ofendodontic and restorative procedures. JOE 1989;15:512.

8. Eleazer PD, Eleazer K R. Air pressures developed beyond theapex from drying root canals with pressurized air. JOE1998;24:833.

9. Shillinburg H Jr, et al. Root dimensions and dowel sizes. J CalifDent Assoc 1982;10:43.

10. Vargo JW, Hartwell GR. Modified endodontics for lengthycanals. JOE 1992;18:512.

11. Leuck M. Root canal morphology of mandibular incisors andcanines [thesis]. Iowa City (IA): Univ. of Iowa; 1973.

12. Kartal N, Yanikoglu FC. Root canal morphology of mandibu-lar incisors. JOE 1992;18:562.

13. Fahid A. Root canal morphology of human maxillary incisorsand canines [thesis]. Iowa City (IA): Univ. of Iowa.

14. Pineda F, Kuttler Y. Mesiodistal and buccolingual roentgeno-graphic investigation of 7275 root canals. Oral Surg1972;33:101.

15. Vertucci FJ, Selig A, Gillis R. Root canal morphology of thehuman maxillary second premolar. Oral Surg 1974;38:456.

16. Grey R. Root canal morphology of maxillary first molar [the-sis]. Univ. of Iowa City (IA); 1974.

17. Seidberg BH, et al. Frequency of two mesiobuccal root canalsin maxillary permanent first molars. J Am Dent Assoc1973;87:852.

18. Pineda F. Roentgenographic investigation of the mesiobuccalroot of the maxillary first molar. Oral Surg 1973;36:253.

19. Pomeranz HH, Fishelberg G. The second mesiobuccal canal ofmaxillary molars. J Am Dent Assoc 1974;88:119.

20. Fahid A, et al. Coronal root canal preparation. Dent Stud J1983;61:S46.

21. Zillich R, Dowson J. Root canal morphology of mandibularfirst and second premolars. Oral Surg 1973;36:783.

22. Baisden MK, et al. Root canal configuration of the mandibularfirst premolar. JOE 1992;18:505.

23. Bjorndal AM, Skidmore AE. Anatomy and morphology ofhuman teeth. Iowa City (IA): Univ. of Iowa; 1983.

24. Green D. Double canals in single roots. Oral Surg 1973;35:689.25. Dempster WT, Adams WJ, Duddles RS. Arrangements in the

jaws of the roots of teeth. J Am Dent Assoc 1963;67:779.26. Hess W. The anatomy of the root canals of the teeth of the per-

manent dentition. London: John Bale and Sons andDanielson; 1925.

27. Kulild JC, Peters DD. Incidence and configuration of canal sys-tems in the mesiobuccal root of maxillary first and secondmolars. JOE 1990;16:311.

28. Neaverth EJ, et al. Clinical investigation (in vivo) of endodon-tically treated maxillary first molars. JOE 1987;10:506.

29. Fahid A. Maxillary second molar with three buccal roots. JOE1988;14:181.

30. Libfeld H, Rolstein I. Incidence of four-rooted maxillary sec-ond molars: Literature review and radiographic survey of1200 teeth. JOE 1989;15:129.

31. Ruprecht A, et al. The incidence of taurodontism in dentalpatients. Oral Surg 1987;63:743.

32. Vertucci FJ, Anthony RL. A scanning electron microscopicinvestigation of accessary foramina in the furcation andpulp chamber floor of molar teeth. Oral Surg 1986;62:319.

33. Niemann RW, et al. Dye ingress in molars: furcation to cham-ber floor. JOE 1993;19:293.

34. Beatty RG, Krell K. Mandibular molars with five canals: reportof two cases. J Am Dent Assoc 1987;114:802.

35. Weine FS, et al. Canal configuration of the mandibular secondmolar using a clinically oriented in vitro method. JOE1988;14:207.

36. Walker RT. Root form and canal anatomy of mandibular secondmolars in a southern Chinese population. JOE 1988;14:325.

37. Yew S-C, Chan K. A retrospective study of endodonticallytreated mandibular first molars in a Chinese population.JOE 1993;19:471.

38. Pomeranz HH, et al. Treatment considerations of the middlemesial canal of mandibular first and second molars. JOE1981;7:565.

39. Sierashi SM. Identification and endodontic management ofthree-canaled maxillary premolars. JOE 1989;15:29.

40. Pecora JD, et al. In vitro study of root canal anatomy of max-illary second premolars. Braz Dent J 1992;3:81.

41. Hartwell G, Bellizi R. Clinical investigation of in vivoendodontically treated mandibular and maxillary molars.JOE 1982;8:555.

42. Trope M, et al. Mandibular premolars with more than one rootcanal in different race groups. JOE 1986;12:343.

43. Walker RT. The root canal anatomy of mandibular incisors ina southern Chinese population. Int Endod J 1988;21:218.

44. Pecora JD, et al. Internal anatomy, direction and number ofroots and size of human mandibular canines. Braz Dent J1993;4:53.

45. Madeina MC, et al. Prevalence of taurodontism in premolars.Oral Surg 1986;61:158.

46. Ingle JI, Zeldow BJ. An evaluation of mechanical instrumenta-tion and the negative culture in endodontic therapy. J AmDent Assoc 1958;57:471.

47. Murgel C, Walton R, et al. A quantitative evaluation of threedifferent cleaning techniques for endodontic files: an SEMexamination [abstract 24]. JOE 1989;15:175

48. Mandel E, et al. Scanning electron microscope observation ofcanal cleanliness. JOE 1990;16:279.

49. Lin L, et al. Histopathologic and histobacteriologic study ofendodontic failure [abstract]. JOE 1986;12.

50. Cailleteau JG, Mullaney TP. Prevalence of teaching apicalpatency and various instrumentation and obturation tech-niques in United States dental schools. JOE 1997;3:394.

51. Kuttler Y. Microscopic investigation of root apexes. J Am DentAssoc 1955;50:544.

52. Mizutani T, et al. Anatomical study of the root apex in maxil-lary anterior teeth. JOE 1992;18:344.

53. Seidler B. Root canal filling: an evaluation and method. J AmDent Assoc 1956;53:567.

54. Ingle JI. The need for endodontic instrument standardization.Oral Surg 1955;8:1211.

55. Green EN. Microscopic investigation of root canal file andreamer width. Oral Surg 1956;10:532.

56. Ingle JI, Levine M. The need for uniformity of endodonticinstruments, equipment and filling materials. In:Transactions of the 2nd International Conference ofEndodontics. Philadelphia: Univ. of Pennsylvania Press;1958. p. 123.

Page 156: Ch10: ENDODONTIC CAVITY PREPARATION

57. Ingle JI. A standardized endodontic technique using newlydesigned instruments and filling materials. Oral Surg1961;14:83.

58. American Dental Association Council on Dental Materials,Instruments and Equipment. Revised ANSI/ADA specifica-tion no. 28 for root canal files and reamers, type-K, and no.Chicago. J Am Dent Assoc Press 2002.

59. Kerekes K. Evaluation of standardized root canal instrumentsand obturating points. JOE 1979;5:145.

60. Serene TP, Loadholt C. Variations in same-size endodonticfiles. Oral Surg 1984;57:200.

61. Cormier CJ, et al. A comparison of endodontic file quality andfile dimensions. JOE 1988;14:138.

62. Seto BG. Criteria for selection of endodontic files [thesis].Seattle: Univ. of Washington School of Dentistry; 1989.

63. Seto BG, et al. Torsional properties of twisted and machinedendodontic files. JOE 1990;16:355.

64. Keate KC, Wong M. A comparison of endodontic file tip qual-ity. JOE 1990;16:488.

65. Stenman E, Spangberg L. Machining efficiency of endodonticK-files and Hedstroem files. JOE 1990;16:375.

66. Stenman E, Spangberg L. Root canal instruments are poorlystandardized. JOE 1993;19:327.

67. Canalda S, Berastegui J. A comparison of bending and tor-sional properties of K-files manufactured with differentmetallic alloys. Int Endod J 1996;29:185.

68. Tepel A, Schafer E, Hoppe W. Properties of endodontic handinstruments used in rotary motion. Part 3: resistance tobending and fracture. JOE 1997;23:141.

69. Wolcott J, Himel VT. Torsional properties of nickel-titaniumversus stainless steel endodontic files. JOE 1997;23:843.

70. Mitchell BF, et al. The effect of autoclave sterilization onendodontic files. Oral Surg 1983;55:204.

71. Morrison S, et al. Effects of sterilization and usage on cuttingefficiency of endodontic instruments [abstract 26]. JOE1989;15:175

72. Mize SB, et al.Effect of sterilization on cyclic fatigue of rotarynickel-titanium endodontic instruments. JOE 1998;24:843.

73. Roth WC, et al. A study of the strength of endodontic files. JOE1983;9:228.

74. Oliet S, Sorin SM. Cutting efficiency of endodontic reamers.Oral Surg 1973;36:243.

75. Webber J, Moser JB, Heuer MA. A method to determine thecutting efficiency of root canal instruments in linearmotion. JOE 1980;6:829.

76. Kazemi RB, Stenman E, Larz SW. The endodontic file as a dis-posal instrument. JOE 1995;21:451.

77. Filho IB, Esberard M, Leonardo R D. Microscopic evaluationof three endodontic files, pre- and postinstrumentation.JOE 1998;24:461.

78. Newman JG, Brantley WA, Gerstein H. A study of the cuttingefficiency of seven brands of endodontic files in linearmotion. JOE 1983;9:316.

79. Neal RG, et al. Cutting ability of K-type endodontic files. JOE1983;9:52.

80. Luks S. An analysis of root canal instruments. J Am Dent Assoc1959;58:85.

81. Gutierrez JH, Gigoux C, Sanhueza I. Physical and chemicaldeterioration of endodontic reamers during mechanicalpreparation. Oral Surg 1969;28:394.

82. Lentine FN. A study of torsional and angular deflection ofendodontic files and reamers. JOE 1979;5:181.

560 Endodontics

83. Chernick LB, Jacobs JJ, Lautenschlauger EP, Heuer MA.Torsional failures of endodontic files. JOE 1976;2:94.

84. Lautenschlager EP, Jacobs JJ, Marshall GW, Heuer MA. Brittleand ductile torsional failures of endodontic instruments.JOE 1977;3:175.

85. Roane JB, Sabala C. Clockwise or counterclockwise? JOE1984;10:349.

86. Sotokawa T. An analysis of clinical breakage of root canalinstruments. JOE 1988;14:75.

87. Montgomery S, et al. File damage during root canal prepara-tion. JOE 1984;10:45.

88. Haikel Y, et al. Dynamic fracture of hybrid endodontic handinstruments compared with traditional files. JOE 1991;17:217.

89. Rowan MB, Nicholls JI, Steiner J. Torsional properties of stain-less steel and nickel-titanium endodontic files. JOE1996;32:341.

90. Buchanan LS. File bending: essential for management ofcurved canals. Endod Rep 1987;Spring/Summer:16.

91. Yesilsoy C, et al. A scanning electron microscopic examinationof surface changes obtained from two variable methods ofprecurving files: a clinical observation. JOE 1986;12:408.

92. Walia H, et al. An initial investigation of the bending and tor-sional properties of Nitinol root canal files. JOE1988;14:346.

93. Walia H, et al. Torsional ductility and cutting efficiency of theNitinol file [abstract 22]. JOE 1989;150:174.

94. Villalobos RL, et al. A method to determine the cutting effi-ciency of root canal instruments in rotary motion. JOE1980;6:667.

95. Felt RA, et al. Flute design of endodontic instruments: Itsinfluence on cutting efficiency. JOE 1982;8:253.

96. Miserendino LJ, et al. Cutting efficiency of endodontic instru-ments. Part II: analysis of tip design. JOE 1986;12:8.

97. Miserendino LJ, et al. Cutting efficiency of endodontic instru-ments. Part I: a quantitative comparison of the tip and flut-ed regions. JOE 1985;11:435.

98. Powell SE, Simon JHS, et al. A comparison of the effect ofmodified and nonmodified instrument tips on apical con-figuration. JOE 1986;12:293.

99. Powell SE, et al. A comparison of the effect of modified andnonmodified tips on apical canal configuration. Part II.JOE 1988;14:224.

100. Roane JB, Sabala CL, et al. The “balanced force” concept forinstrumentation of curved canals. JOE 1985;11:203.

101. Sabala CL, Roane JB, et al. Instrumentation of curved canalsusing a modified tipped instrument: a comparison study.JOE 1988;14:59.

102. Sepic AO, et al. Comparison of Flex-R-files and K-files incurved canals [abstract]. JOE 1988;14:194.

103. McKendry DJ, et al. Clinical incidence of canal ledging with anew endodontic file [abstract]. JOE 1988;14:194.

104. Dummer PMH, Alomari MAO, Bryant S. Comparison of per-formance of four files with rounded tips during shaping ofsimulated root canals. JOE 1998;24:363.

105. Machian GR, et al. The comparative efficiency of four types ofendodontic instruments. JOE 1982;8:398.

106. Mizrahi SJ, Tucker JW, Seltzer S. A scanning electron micro-scopic study of the efficacy of various endodontic instru-ments. JOE 1975;1:324.

107. Miserendino LJ, et al. Cutting efficiency of endodontic handinstruments. Part IV. Comparison of hybrid and tradition-al designs. JOE 1988;14:451.

Page 157: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 561

108. Yguel-Henry S, et al. High precision, simulated cutting effi-ciency measurement of endodontic root canal instruments:influence of file configuration and lubrication. JOE1990;16:418.

109. Newsletter: Endodontic “S” file found to be fast and efficient.Clin Res Assoc 1985;9:10.

110. El Deeb ME, Boraas JC. The effect of different files on thepreparation shape of curved canals. Int Endod J 1985;18:1.

111. American National Standards Institute/ADA specification no.58 for root canal files, Type H (Hedstroem). J Am DentAssoc 1989;118:239.

112. Bolger WL, et al. A comparison of the potential for breakage:the Burns Unifile versus Hedstroem files. JOE 1985;11:110.

113. Stenman E, Spangberg LSW. Machining efficiency of Flex-R,K-Flex, Trio-Cut and S-Files. JOE 1990;16:575.

114. Wildey WL, Senia S. A new root canal instrument and instru-mentation technique: a preliminary report. Oral Surg1989;67:198.

115. Leseberg DA, Montgomery S. The effects of Canal Master,Flex-R, and K-Flex instrumentation on root canal configu-ration. JOE 1991;17:59.

116. Wildey WL, Senia ES, Montgomery S. Another look at rootcanal instrumentation. Oral Surg 1992;74:499.

117. Baumgartner JC, et al. Histomorphometric comparison ofcanals prepared by four techniques. JOE 1992;18:530.

118. Briseno BM, et al. Comparison by means of a computer-sup-ported device of the enlarging characteristics of two differ-ent instruments. JOE 1993;19:281.

119. Cirnis GJ, et al. Effect of three file types on the apical prepara-tions of moderately curved canals. JOE 1988;14:441.

120. Sepic AO, et al. A comparison of Flex-R files and K-type filesfor enlargement of severely curved molar root canals. JOE1989;15:240.

121. Calhoun G, Montgomery S. The effects of four instrumenta-tion techniques on root canal shape. JOE 1988;14:273.

122. Alodeh MHA, Dummer PMH. The comparison of the abilityof K-files and Hedstroem files to shape simulated rootcanals in resin blocks. Int Endod J 1989;22:226.

123. Briseño BM, Sonnabend E. The influence of different rootcanal instruments on root canal preparation: an in vitrostudy. Int Endod J 1991;24:15.

124. Stenman E, Spångberg LSW. Machining efficiency ofendodontic files: a new methodology. JOE 1990;16:151.

125. Rueggenberg FA, Powers JM. Mechanical properties ofendodontic broaches and effects of bead sterilization. JOE1988;14:133.

126. Buehler WJ, Wang E. Effect of low temperature phase on themechanical properties of alloy near composition NiTi. JAppl Physio 1963;34:1475.

127. Civjan S, Huget EF, DeSimon LB. Potential applications of cer-tain nickel-titanium (nitinol) alloys. J Dent Res 1975;54:1.

128. Walia H, Brantley WA, Gerstein H. An initial investigation ofthe bending and torsional properties of nitinol root canalfiles. JOE 1988;14:346.

129. StoeckelD, Yu W. Superelastic Ni-Ti wire. Wire J Int 1991;March:45–50.

130. Kazemi RB, Stenman E, Spångberg LSW. Machining efficiencyand wear resistance of nickel-titanium endodontic files.Oral Surg 1996;81:596.

131. Serene TP, Adams JD, Saxena A. Physical tests, in nickel-titani-um instruments: application in endodontics. St. Louis:Ishiyaku EuroAmerica; 1995.

132. Hsich M, Yu F. The basic research on NiTi shape-memoryalloy-anti-corrosive test and corrosive test and histologicalobservation. Chin Med J 1982;1:105–20.

133. Glickman GN, Himel VT, Serene TP. Point-counterpoint: thenickel-titanium paradigm in endodontics. Presented at theAmerican Association of Endodontics 54th AnnualSession, 1997. Seattle, WA.

134. Canalda S, Berastequi J. A comparison of bending and tor-sional properties of K files manufactured with differentmetallic alloys. Int Endod J 1996;29:185.

135. Canalda SC, Brau AE, Berastegui JE. Torsional and bendingproperties of stainless steel and nickel-titaniumCanalMaster U and Flexogate instruments. Endod DentTraumatol 1996;12:141.

136. Tepel J, Schafer E, Hoppe W. Properties of endodontic handinstruments used in rotary motion. Part 3. Resistance tobending and fracture. JOE 1997;23:141.

137. Wolcott J, Himel VT. Torsional properties of nickel-titaniumversus stainless steel endodontic files. JOE 1997;23:217.

138. Pruett JP, et al. Cyclic fatigue testing of NiTi endodonticinstruments. JOE 1997;27:77.

139. Himel VT, Ahmed KM, Wood DM, Alhadainy HA. An evalua-tion of Nitinol and stainless steel files used by dental studentsin a laboratory proficiency exam. Oral Surg 1995;79:232.

140. Ahmed K, Himel VT. Instrumentation effects of endodonticfiles on canal shape and apical foramen [abstract 19]. JOE1993;19:208

141. Himel VT, Moore RE, Hicks VE. The effects that 3 endodonticfiles have on canal shape [abstract]. JOE 1994;20.

142. Gambill JM, Alder M, Del Rio CE. Comparison of nickel-tita-nium and stainless steel hand file instrumentation usingcomputed tomography. JOE 1996;22:369.

143. Tepel J, Schafer E, Hoope W. Properties of endodontic handinstrumentation used in rotary motion. Part 1. Cuttingefficiency. JOE 1995;21:418.

144. Elliot LM, CurtisRV, Pitt Ford TR. Cutting pattern of nickel-titanium files using two preparation techniques. EndodDent Traumatol 1998;14:10.

145. Zakariasen KA, Zakariasen KL. Comparison of hand,hand/sonic, and hand/mechanical instrumentation meth-ods. J Dent Res 1994;73:215.

146. Zakariasen KL, Buerschen GH, Zakariasen KA. A comparisonof traditional and experimental instruments for endodon-tic instrumentation. J Dent Res 1994;73:20.

147. Hulsman M, Stryga F. Comparison of root canal preparationusing different automated devices and hand instrumenta-tion. JOE 1993;19:141.

148. Dihn Q. An in-vitro evaluation of the Giromatic instrument inthe mechanical preparation of root canals [thesis]. Univ. ofMinnesota; Minn. 1972.

149. Molven O. A comparison of the dentin removing ability of fiveroot canal instruments. Scand J Dent Res 1970;78:500.

150. O’Connell DT, Brayton SM. Evaluation of root canal prepara-tion with two automated endodontic handpieces. OralSurg 1975;39:298.

151. Klayman S, Brilliant J. A comparison of the efficacy of serialpreparation versus Giromatic preparation. JOE 1974;1:334.

152. Sargenti A. Engine powered canal preparation. Addendum toEndodontics. Locarno (Switzerland): AGSA PublicationScientifiques; 1974.

153. Weine F, et al. Effect of preparation with endodontic hand-pieces on original canal shape. JOE 1976;2:298.

Page 158: Ch10: ENDODONTIC CAVITY PREPARATION

154. Harty F, Stock C. The Giromatic system compared with handinstrumentation in endodontics. Br Dent J 1974;6:233.

155. Felt RA, Moser JB, Heuer MA. Flute design of endodonticinstruments: its influence on cutting efficiency. JOE1982;8:253.

156. Spyropoulos S, et al. The effect of Giromatic files on the prepa-ration shape of severely curved canals. Int Endod J1987;20:133.

157. Luebke NH, Brantley WA. Physical dimensions and torsionalproperties of rotary endodontic instruments. I.Gates-Glidden drills. JOE 1990;16:438.

158. Luebke NH. Performance of Gates-Glidden drill with anapplied deflection load. JOE 1989;15:175.

159. Luebke NH, Brantley WA. Torsional and metallurgical proper-ties of rotary endodontic instruments. II Stainless steelGates-Glidden drills. JOE 1991;17:319.

160. Johnson TA, Zelikow R. Ultrasonic endodontics: a clinicalreview. J Am Dent Assoc 1987;114:655.

161. Richman MJ. The use of ultrasonics in root canal therapy androot resection. J Dent Med 1957;12:12.

162. Cunningham WT, Martin H. A scanning electron microscopeevaluation of root canal debridement with the endosonicultrasonic synergistic system. Oral Surg 1975;53:527.

163. Martin H. Ultrasonic disinfection of the root canal. Oral Surg1976;42:92.

164. Martin H, Cunningham WT, et al. Ultrasonic versus hand fil-ing of dentin: a quantitative study. Oral Surg 1980;49:79.

165. Martin H, Cunningham WT, Norris JP. A quantitative com-parison of the ability of diamond and K-type files toremove dentin. Oral Surg 1980;50:566.

166. Martin H, Cunningham WT. The effect of Endosonic andhand manipulation on the amount of root canal materialextruded. Oral Surg 1982;53:611.

167. Martin H, Cunningham WT. An evaluation of postoperativepain incidence following Endosonic and conventional rootcanal therapy. Oral Surg 1982;54:74.

168. Cunningham WT, Martin H, Forrest WR. Evaluation of rootcanal debridement with the Endosonic ultrasonic synergis-tic system. Oral Surg 1982;53:401.

169. Cunningham WT, Martin H. A scanning electron microscopeevaluation of root canal debridement with the Endosonicultrasonic synergistic system. Oral Surg 1982;53:527.

170. Cunningham WT, Martin H, et al. A comparison of antimi-crobial effectiveness of Endosonic and hand root canaltherapy. Oral Surg 1982;54:238.

171. Martin H. High tech root canal preparation and obturationand new instrumentation. Alpha Omegan 1990;83:55.

172. Cameron JA. The use of ultrasonics in the removal of thesmear layer: a scanning electron microscope study. JOE1983;9:289.

173. Goodman A, et al. The efficacy of serialization technique ver-sus a serialization/ultrasonic technique [abstract]. JOE1984;10:118.

174. Chenail B, Teplitsky PE. Performance of endosonics in curvedroot canals [abstract]. JOE 1985;11:369.

175. Barnett F, et al. Bacteriological status of the root canal aftersonic, ultrasonic and hand instrumentation [abstract]. JOE1985;11:148.

176. Collinson DM, et al. Microbiological assessment of ultrasonicsin root canal therapy [abstract]. JOE 1986;12:131.

177. Lev R, et al. Efficacy of the step-back versus a step-back/ultra-sonic technique [abstract]. JOE 1986;12:128.

562 Endodontics

178. Scott GL, Walton RE. Ultrasonic endodontics: the wear ofinstruments with usage. JOE 1986;12:279.

179. Krell KV, Neo J. The use of ultrasonic endodontic instrumen-tation in the retreatment of a paste-filled endodontic tooth.Oral Surg 1985;60:100.

180. Yamaguchi M, et al. The use of ultrasonic instrumentation inthe cleansing and enlargement of the root canal. Oral Surg1988;65:349.

181. Cameron JA. The effect of ultrasonic endodontics on the tem-perature of the root canal wall. JOE 1988;14:554.

182. Haidet J, et al. An in vivo comparison of the step-back tech-nique versus a step-back/ultrasonic technique in humanmandibular molars. JOE 1989;15:195.

183. Briggs PFA, et al. The dentine-removing characteristics of anultrasonically energized K-file. Int Endod J 1989;22:259.

184. Baker MC, et al. SEM comparison of ultrasonic versus handinstrumentation of root canals [abstract]. JOE1985;110:138.

185. Pedicord D, et al. Hand versus ultrasonic instrumentation: itseffect on canal shape and instrumentation time. JOE1986;12:375.

186. Chenail BL, Teplitsky PE. Endosonics in curved root canals.Part II. JOE 1988;14:214.

187. Baker MC, et al. Ultrasonic compared with hand instrumenta-tion: a scanning electron microscope study. JOE1988;14:435.

188. Krell KV, Johnson RJ. Irrigation patterns of ultrasonic files.Part II. Diamond coated files. JOE 1988;14:535.

189. Walsh CL, et al. The effect of varying the ultrasonic power set-ting on canal preparation. JOE 1990;16:273.

190. Ahmad M, Pitt Ford TR, Crum LA. Ultrasonic debridement ofroot canals: an insight into the mechanisms involved. JOE1987;13:93.

191. Ahmad M, et al. Ultrasonic debridement of root canals:acoustic streaming and its possible role. JOE 1987;13:490.

192. Ahmad M, et al. Ultrasonic debridement of root canals:acoustic cavitation and its relevance. JOE 1988;14:486.

193. Archer R, et al. An in vivo evaluation of the efficacy of ultra-sound after step-back preparation in mandibular molars.JOE 1992;18:549.

194. Walmsley AD, Williams AR. Effects of constraint on the oscil-latory pattern of Endosonic files. JOE 1989;15:189.

195. Krell KV, et al. Irrigation patterns during ultrasonic canalinstrumentation. Part I. K-type files. JOE 1988;14:65.

196. Lumley PJ, Walmsley AD. Effect of precurving on the per-formance of Endosonic K-files. JOE 1992;18:232.

197. Ahmad M, et al. Effectiveness of ultrasonic files in the disrup-tion of root canal bacteria. Oral Surg 1990;70:328.

198. Ahmad M, Pitt Ford TR. Comparison of two ultrasonic unitsin shaping curved canals. JOE 1989;15:457.

199. Ahmad M. Shape of the root canal after ultrasonic instrumen-tation with K-Flex files. Endod Dent Traumatol 1990;6:104.

200. Walmsley AD, et al. The oscillatory pattern of sonically pow-ered endodontic files. Int Endod J 1989;22:125.

201. Cohen S, Burns RC. Pathways of the pulp. 3rd ed. St. Louis: CVMosby; 1984.

202. Dummer PMH, et al. Shaping of simulated root canals in resinblocks using files activated by a sonic handpiece. Int EndodJ 1989;22:211.

203. Bolanos OR, et al. A comparison of engine and air-driveninstrumentation methods with hand instrumentation. JOE1988;14:392.

Page 159: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 563

204. Ehrlich AD, et al. Effect of sonic instrumentation on the apicalpreparation of curved canals. JOE 1989;15:200.

205. Tronstad L, Niemczyk SP. Efficacy and safety tests of six auto-mated devices for root canal instrumentation. Endod DentTraumatol 1986;2:270.

206. Miserendino LJ, et al. Cutting efficiency of endodontic instru-ments. Part III. Comparison of sonic and ultrasonic instru-ment systems. JOE 1988;14:24.

207. Kielt LW, Montgomery S. The effect of Endosonic instrumen-tation in simulated root canals. JOE 1987;13:215.

208. Zakariasen KL, et al. Today’s sonics: using the combinedhand/sonic endodontic technique. J Am Dent Assoc1992;123:67.

209. Walker TL, del Rio CE. Histological evaluation of ultrasonicand sonic instrumentation of curved root canals. JOE1989;15:49.

210. Yahya AS, El Deeb ME. Effect of sonic versus ultrasonic instru-mentation on canal preparation. JOE 1989;15:235.

211. Reynolds MA, et al. An in vitro histological comparison of thestep-back, sonic and ultrasonic instrumentation tech-niques in small curved canals. JOE 1987;13:307.

212. Lumley PJ, et al. Cleaning of oval canals using ultrasonic orsonic instrumentation. JOE 1993;19:453.

213. Lev R, et al. An in vitro comparison of the step-back techniqueversus a step-back/ultrasonic technique for 1 and 3 min-utes. JOE 1987;11:523.

214. Stamos DE, et al. An in vitro comparison study to quantitatethe debridement ability of hand, sonic and ultrasonicinstrumentation. JOE 1987;13:434.

215. Goldman M, et al. A silicone model method to compare threemethods of preparing the root canal. Oral Surg 1989;68:457.

216. Pugh RJ, Goerig AC, et al. A comparison of four endodonticvibration systems. Gen Dent 1989;37:296.

217. Barnett F, et al. Bacteriologic status of the root canal aftersonic, ultrasonic and hand instrumentation. Endod DentTraumatol 1985;1:228.

218. Fairbourn DR, et al. The effect of four preparation techniqueson the amount of apically extruded debris. JOE1987;13:102.

219. Baumgartner JC, Cuenin PR. Efficacy of several concentra-tions of sodium hypochlorite for root canal irrigation. JOE1992;18:605.

220. Trepagnier CM, Madden RM, Lazzari EP. Quantitative study ofsodium hypochlorite as an in vitro endodontic irrigant.JOE 1977;3:194.

221. Spångberg L, Engstrom B, Langeland K. Biological effects ofdental materials: III. Toxicity and antimicrobial effects ofendodontic antiseptics in vitro. Oral Surg 1974;55:856.

222. Bystrom A, Sundquist G. Bacteriological evaluation of theeffect of 0.5 percent sodium hypochlorite in endodontictherapy. Oral Surg 1983;55:307.

223. Siqueira JF Jr, Batista MM, Fraga RC, de Uzeda M.Antibacterial effects of endodontic irrigants on black-pig-mented gram-negative anaerobes and facultative bacteria.JOE 1998;24:414.

224. Rosenfeld EF, James GA, Burch BS. Vital pulp tissue responseto sodium hypochlorite. JOE 1978;4:140.

225. Hand RE, Smith ML, Harrison JW. Analysis of the effect ofdilution on the necrotic tissue dissolution property of sodi-um hypochlorite. JOE 1978;4:60.

226. Thé SD. The solvent action of sodium hypochlorite on fixedand unfixed necrotic tissue. Oral Surg 1979;47:558.

227. Hasselgren G, et al. Effects of calcium hydroxide and sodiumhypochlorite on the dissolution of necrotic porcine muscletissue. JOE 1988;14:125.

228. Wadachi R, Araki K, Suda H. Effect of calcium hydroxide onthe dissolution of soft tissue on the root canal wall. JOE1998;24:326.

229. Yang SF, Riveria EM, Walton RE, Baumgartner KR. Canaldebridement: effectiveness of sodium hypochlorite and cal-cium hydroxide as medicaments. JOE 1998;20:276.

230. Johnson BR, Remeikis NA. Effective shelf-life of preparedsodium hypochlorite solution. JOE 1993;19:40.

231. Cunningham WT, Balekjian AY. Effect of temperature on col-lagen-dissolving ability of sodium hypochlorite endodon-tic irrigant. Oral Surg 1980;49:175.

232. Cunningham WT, Joseph SW. Effect of temperature on thebactericidal action of sodium hypochlorite endodonticirrigant. Oral Surg 1980;50:569.

233. Raphael D, Wong TA, Moodnick R, Borden BG. The effect oftemperature on the bactericidal efficiency of sodiumhypochlorite. JOE 1981;7:330.

234. Buttler TK, Crawford JJ. The detoxifying effect of varying con-centrations of sodium hypochlorite on endotoxins. JOE1982;8:59.

235. Byström A, Sundqvist G. The antibacterial action of sodiumhypochlorite and EDTA in 60 cases of endodontic therapy.Int Endod J 1985;18:35.

236. Fischer R, Huerta J. Effects of pH on microbial flora of necrot-ic root canals. JOE 1984;10:153.

237. Nicholaus BE, et al. The bactericidal effect of citric acid andsodium hypochlorite on anaerobic bacteria. JOE 1988;14:31.

238. Baumgartner JC, Ibay AC. The chemical reactions of irrigantsused for root canal debridement. JOE 1987;13:47.

239. Kaufman AY, et al. New chemotherapeutic agent for root canaltreatment. Oral Surg 1978;46:283.

240. Jeansonne MJ, White RR. A comparison of 2% chlorhexidinegluconate and 5.25% sodium hypochlorite as antimicrobialendodontic irrigants. JOE 1994;20;276.

241. Validaty A, Pitt Ford TR, Wilson RF. Efficacy of chlorhexidinein disinfecting dentinal tubules in vitro. Endod DentTraumatol 1993;9:243.

242. Yesiloy C, Whittaker E, Cleveland E, et al. Antimicrobial andtoxic effects of established and potential root canal irrig-ants. JOE 1995;21:513.

243. Lee LW, Lan WH, Wang GY. An evaluation of chlorhexidine asan endosonic irrigant. J Formos Med Assoc 1990;89:491.

244. Parson GJ, Patterson SS, Newton CW, et al. Uptake and releaseof chlorhexidine by bovine pulp and dentin specimens andtheir subsequent acquisition of antibacterial properties.Oral Surg 1980;49:455.

245. Kuruvilla JR, Kamath MP. Antimicrobial effect of 2.5% sodi-um hypochlorite and 0.2% chlorhexidine gluconate sepa-rately and combined as endodontic irrigants. JOE1998;24:472.

246. White RR, Hays GL, Janer LR. Residual antimicrobial activityafter canal irrigation with chlorhexidine. JOE 1997;23:231.

247. Kaufman AY. The use of dequalinium acetate as a disinfectantand chemotherapeutic agent in endodontics. Oral Surg1981;51:434.

248. Kaufman AY, Greenberg I. Comparative study of the configura-tion and the cleanliness level of root canals prepared with theaid of sodium hypochlorite and bis-dequalinium-acetatesolutions. Oral Surg 1986;62:191.

Page 160: Ch10: ENDODONTIC CAVITY PREPARATION

249. Mohd Sulong MZA. The incidence of postoperative pain aftercanal preparation of open teeth using two irrigation regi-mens. Int Endod J 1989;22:248.

250. Harrison JW, Svec TA, Baumgartner JC. Analysis of clinicaltoxicity of endodontic irrigants. JOE 1978;4:6.

251. Ram A. Effectiveness of root canal irrigation. Oral Surg1977;44:306.

252. Cameron JA. The use of sodium hypochlorite activated byultrasound for the debridement of infected, immature rootcanals. JOE 1986;12:550.

253. Cameron JA. The synergistic relationship between ultrasoundand sodium hypochlorite: a scanning electron microscopicstudy. JOE 1987;13:541.

254. Griffiths BM, Stock CJR. The efficiency of irrigants in remov-ing root canal debris when used with an ultrasonic prepa-ration technique. Int Endod J 1986;19:277.

255. Sjögren U, Sundqvist G. Bacteriologic evaluation of ultrasonicroot canal instrumentation. Oral Surg 1987;63:366.

256. Krell KV, McKendry DJ. The use of a chelating agent and 2.5%NaOCl with sonic and ultrasonic endodontic instrumenta-tion [abstract]. JOE 1988;14:199.

257. Walker TL, del Rio CE. Histological evaluation of ultrasonicdebridement comparing sodium hypochlorite and water.JOE 1991;17:66.

258. Druttman ACS, Stock CJR. An in vitro comparison of ultra-sonic and conventional methods of irrigant replacement.Int Endod J 1989;22:174.

259. Teplitsky PE, et al. Endodontic irrigation—a comparison ofendosonic and syringe delivery systems. Int Endod J1987;20:233.

260. Buchanan LS. Endodontics Palm Springs Seminar, PalmSprings, California, April 8, 1989.

261. Kaufman AY. Facial emphysema caused by hydrogen peroxideirrigation: report of case. JOE 1981;7:470.

262. Abou-Rass M, Piccinino MU. The effectiveness of four clinicalirrigation methods on the removal of root canal debris.Oral Surg 1982;54:323.

263. Moser JB, Heuer MA. Forces and efficiency in endodontic irri-gation systems. Oral Surg 1982;53:425.

264. Walton RE, Torabinejad M. Principles and practice ofendodontics. Philadelphia: WB Saunders; 1989.

265. Chow TW. Mechanical effectiveness of root canal irrigation.JOE 1983;9:475.

266. Salzgeber RM, Brilliant JD. An in vitro study of the penetrationof a root canal irrigating solution in root canals. JOE1977;3:394.

267. Senia ES, Marshall FJ, Rosen S. The solvent action of sodiumhypochlorite on the pulp tissue of extracted teeth. OralSurg 1971;31:96.

268. Tidmarsh BG. Acid-cleansed and resin-sealed root canals. JOE1978;4:117.

269. Wayman BE, Kopp WM, Pinero GJ. Citric and lactic acids asroot canal irrigants in vitro. JOE 1979;5:258.

270. Baumgartner JC, et al. A scanning electron microscopic evalu-ation of root canal debridement using saline, sodiumhypochlorite, and citric acid. JOE 1984;10:525.

271. Cecic PA, et al. The comparative efficiency of final endodonticcleansing procedures in removing a radioactive albuminfrom root canal systems. Oral Surg 1984;58:336.

272. Kaufman AY, et al. New chemotherapeutic agent for root canaltreatment. Oral Surg 1978;46:283.

564 Endodontics

273. Berry EA, et al. Dentin surface treatments for the removal ofthe smear layer: an SEM study. J Am Dent Assoc1987;115:65.

274. Nygaard Østby B. Chelation in root canal therapy. OdontolTidskr 1957;65:3.

275. Fehr F, Nygaard Østby B. Effect of EDTAC and sulfuric acid onroot canal dentin. Oral Surg 1963;16:199.

276. Valdrighi L. The demineralizing efficiency of EDTA solutionson dentin. Oral Surg 1981;52:446.

277. Goldberg F, Abramovich A. Analysis of the effect of EDTAC onthe dentinal walls of the root canal. JOE 1977;3:101.

278. McComb D, Smith DC. A preliminary electron microscopicstudy of root canals after endodontic procedures. JOE1975;1:238.

279. Goldman LB, Goldman M, Kronman JH, Sun Lin P. The effi-cacy of several irrigating solutions for endodontics: a scan-ning electron microscopic study. Oral Surg 1981;52:197.

280. Goldberg F, Spielberg C. The effect of EDTAC and the varia-tion of its working time analyzed with scanning electronmicroscopy. Oral Surg 1982;53:74.

281. Mader CL, et al. Scanning electron microscopic investigationof the smeared layer on root canal walls. JOE 1984;10:477.

282. Baumgartner J, Mader CL. A SEM survey of root canaldebridement using three irrigants [abstract]. JOE1985;11:144

283. Berg MS, et al. A comparison of five irrigating solutions: a semstudy [abstract]. JOE 1984;10.

284. Goldberg F, et al. Effect of irrigation solutions on the filling oflateral root canals. Endod Dent Traumatol 1986;2:65.

285. Goldberg F, Massone EJ. Instrumetacion manual y ultrasonica.Rev Esp Endod 1985;3:61.

286. Berg MS, et al. A comparison of five irrigating solutions: ascanning electron microscopic study. JOE 1986;12:192.

287. Baumgartner JC, Mader CL. A scanning electron microscopicevaluation of four root canal irrigation regimens. JOE1987;13:147.

288. El-Tagouri H, et al. The effectiveness of the Canal FinderSystem. JOE 1988;14:194.

289. Cengiz T, et al. The effect of dentinal tubule orientation on theremoval of smear layer by root canal irritants. A scanningelectron microscopic study. Int Endod J 1990;23:163.

290. Stewart GG, et al. EDTA and urea peroxide for root canalpreparation. J Am Dent Assoc 1969;78:335.

291. Brown JI, Doran JE. An in vitro evaluation of the particle flota-tion capability of various irrigating solutions. Calif Dent J1975;3:60.

292. Zubriggen T, del Rio C, Brady JM. Post-debridement retentionof endodontic reagents: a quantitative measurement withradioiostope. JOE 1975;1:298.

293. Cooke HG, Grower MF, del Rio C. Effects of instrumentationwith a chelating agent on the periradicular seal of obturat-ed root canals. JOE 1976;2:312.

294. Inoue N, Skinner DH. A simple and accurate way of measur-ing root canal length. JOE 1985;11:421.

295. Bramante CM, Berbert A. A critical evaluation of some meth-ods of determining tooth length. Oral Surg 1974;37:463.

296. Seidberg BH, Alibrandi BU, Fine H, Logue B. Clinical investi-gation of measuring working length of root canals with anelectronic device and with digital-tactile sense. J Am DentAssoc 1975;90:379.

297. Simon JHS. The apex: how critical is it? Gen Dent1994;42:330.

Page 161: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 565

298. Glossary: contemporary terminology for endodontics. 6th ed.Chicago: American Association of Endodontists; 1998.

299. Kuttler Y. Microscopic investigation of root apexes. J Am DentAssoc 1955;50:544.

300. Dummer PMH, McGinn JH, Ree DG. The position and topog-raphy of the apical constriction and apical foramen. IntEndod J 1984;17:192.

301. Palmer MJ, Weine FS, Healey HJ. Position of the apical fora-men in relation to endodontic therapy. J Can Dent Assoc1971;8:305.

302. Green D. A stereomicroscopic study of the root apicies of 400maxillary and mandibular teeth. Oral Surg 1956;9:249.

303. Green FN. Microscopic investigation of root canal diameters. JAm Dent Assoc 1958;57:636.

304. Green D. Stereomicroscopic study of 700 root apices of maxil-lary and mandibular teeth. Oral Surg 1960;13:728.

305. Chapman CE. A microscopic study of the apical region ofhuman anterior teeth. J Br Endod Soc 1969;3:52.

306. Morfis A, et al. Study of the apices of human permanent teethwith the use of a scanning electronic microscope. Oral Surg1994;77:172.

307. Guiterrez G, Aguayo P. Apical foraminal openings in humanteeth. Number and location. Oral Surg 1995;79:769.

308. Langeland K, cited in Riccuci D. Apical limit of root canalinstrumentation and obturation. Int Endod J 1998;31:384.

309. Kuttler Y. A precision and biologic root canal filling technique.J Am Dent Assoc 1958;58:38.

310. Storms JL. Factors that influence success of endodontic treat-ment. J Can Dent Assoc 1969;35:83.

311. Levy AB, Glatt L. Deviation of the apical foramen from theradiographic apex. J NJ State Dent Soc 1970;41:12.

312. Burch JG, Hulen S. The relationship of the apical foramen tothe anatomic apex of the tooth root. Oral Surg 1972;34:262.

313. Tamse A, Kaffe I, Fishel D. Zygomatic bone and interferencewith correct radiographic diagnosis in maxillary molarendodontics. Oral Surg 1980;50:563.

314. Farber JP, Bernstein M. The effect of instrumentation on rootcanal length as measured with an electronic device. JOE1983;9:114.

315. Caldwell JJ. Change in working length following instrumenta-tion of molar canals. Oral Surg 1976;11:114.

316. Rivera EM, Seraji MK. Effect of recapitulation on accuracy ofelectronically determined canal length. Oral Surg 1993;76:225.

317. Hasselgren G. Where shall the root filling end? N Y State DentJ 1994;June/July:34.

318. Calleteau JG, Mullaney TP. Prevalence of teaching apicalpatency and various instrumentation and obturation tech-niques in United States dental schools. JOE 1997;23:394.

319. Schilder H. Cleaning and shaping the root canal. Dent ClinNorth Am 1971;18:269.

320. Allison CA, Weber CR, Walton RE. The influence of themethod of canal preparation on the quality of apical andcoronal seal. JOE 1979;5:298.

321. George JW, Michanowicz AE, Michanowicz JR. A method ofcanal preparation to control apical extrusion of low-tem-perature gutta-percha. JOE 1987;13:18.

322. Bhaskar SN, Rappaport HM. Histologic evaluation ofendodontic procedures in dogs. Oral Surg 1971;31:526.

323. Seltzer S, Soltanoff W, Smith J. Biologic aspects of endodon-tics. Part V. Peripical tissue reactions to root canal instru-mentation beyond the apex and root canal fillings short ofand beyond the apex. Oral Surg 1973;36:725.

324. Oguntebi B, Slee AM, Tanker JM, Langeland K. Predominantmicroflora associated with human dental periapicalabscesses. J Clin Microbiol 1982;15:964.

325. Pascon EA, Introcaso JH, Langeland K. Development of pre-dictable periapical lesion monitored by subtraction radiog-raphy. Endod Dent Traumatol 1987;3:192.

326. Guldener P, Imobersteg C. Neu Methode zur exaktenLangeneinstellung von Wurkzelkand - Instrument. SchweizMschr Zahneheilk 1972;82:280.

327. Katz A, Tamse A, Kaufman AY. Tooth length determination: areview. Oral Surg 1991;72:238.

328. Steffen H, Splieth CH, Behr K. Comparison of measurementsobtained with hand files or the Canal Leader attached toelectronic apex locators: an in vitro study. Int Endod J1999;32:103.

329. Ingle JI. Endodontic instruments and instrumentation. DentClin North Am 1957;11:805.

330. Dummer PMH, Lewis JM. An evaluation of the endometricprobe in root canal length estimation. Int Endod J1987;20:25.

331. Vande Voorde H, Bjorndahl A. Estimating endodontic “work-ing length” with paralleling radiographs. Oral Surg1969;27:106.

332. Weine F. Endodontic therapy. St. Louis: CV Mosby; 1982.333. Forsberg J. Radiographic reproduction of endodontic “work-

ing length” comparing the paralleling and bisecting-angletechniques. Oral Surg 1987;64:353.

334. Olson AK, Goerig AC, et al. The ability of the radiograph todetermine the location of the apical foramen. Int Endod J1991;24:28.

335. Von der Lehr WN, Marsh RA. A radiographic study of thepoint of endodontic egress. Oral Surg 1973;35:105.

336. Cox VS, Brown CE, Bricker SL. Radiographic interpretation ofendodontic file length. Oral Surg 1972;72:340.

337. Eckerboom M, Magnusson T. Evaluation of technical qualityof endodontic treatment—reliability of intra-oral radi-ographs. Endod Dent Traumatol 1997;13:259.

338. Bhakdinarenk A, Manson-Hing LR. Effect of radiographictechnique upon the prediction of tooth length in intraoralradiography. Oral Surg 1981;51:100.

339. Teo CS, Chan NC, Loh HS. The position of the apical foramenof the permanent incisors. Aust Dent J 1988;33:51.

340. Mandel E. Obturation canalaire et position du foramen apical.Rev Franc Endod 1983;31:49.

341. Shearer AC, Horner K, Wilson NHF. Radiovisiography forlength estimation in root canal treatment: an in vitro com-parison with conventional radiography. Int Endod J1991;24:233.

342. Shearer AC, Horner K, Wilson NHF. Radiography for imagingroot canals: an in vitro comparison with conventional radi-ography. Quintessence Int 1990;21:789.

343. Horner K, Shearer AC, Walker A, Wilson NHT.Radiovisiography: initial evaluation. Br Dent J 1990;168:244.

344. Griffiths BM, Brown JA, Hyatt AT, Linney AD. Comparison ofthree imaging techniques for assessing endodontic workinglength. Int Endod J 1992;25:279.

345. Sanderink GCG, Huiskens R, van der Stelt PF, et al. Imagequality of direct digital intraoral sensors in assessing rootcanal length. The RadioVisioGraphy, Visualix/VIXA, Sens-a-Ray and Flash Dent Systems compared with Ektaspeedfilms. Oral Surg 1994;78:125.

Page 162: Ch10: ENDODONTIC CAVITY PREPARATION

346. Hedrick RT, Dove SB, Peters DP, McDavid WD. Radiographicdetermination of canal length: direct digital radiographyversus conventional radiography. JOE 1994;20:320.

347. Leddy BJ, Miles DA, Newton CW, Brown CE. Interpretation ofendodontic file lengths using RadioVisioGraphy. JOE1994;20:542.

348. Ong EY, Pitt Ford TR. Comparison of Radiovisiography withradiographic film in root length determination. Int EndodJ 1995;28:25.

349. Ellingsen MA, Harrington GW, Hollender LG. Radiovisiographyversus conventional radiography for detection of smallinstruments in endodontic length determination. Part 1. Invitro evaluation. JOE 1995;21:326.

350. Garcia AA, Navarro LF, Castelló VU, Laliga RM. Evaluation ofdigital radiography to estimate working length. JOE1997;23:363.

351. Cederberg RA, Tidwell E, Frederiksen NL, Benson BW.Endodontic working length assessment. Comparison ofstorage phosphor digital imaging and radiographic film.Oral Surg 1998;85:325.

352. San Marco S, Montgomery S. Use of xeroradiography for lengthdetermination in endodontics. Oral Surg 1984;57:308.

353. Alexander JB, Andrews JD. A comparison between xeroradi-ographs and conventional radiographs as an aid in rootcanal therapy for maxillary molars. Oral Surg 1989;67:443.

354. Barkhordar RA, Nicholson RJ, Nguyen NT, Abbasi J. An evalu-ation of xeroradiographs and radiographs in length deter-mination in endodontics. Oral Surg 1987;65:747.

355. White S, Gratt BM. Clinical trials of intra-oral dental xerora-diography. J Am Dent Assoc 1979;99:810.

356. Berman LH, Fleischman SB. Evaluation of the accuracy of theNeosono-D electronic apex locator. J Endod 1984;10:164.

357. Bal CS, Chaudhary M. Evaluation of accuracy of an electricdevice (Neosono-D/SE) for measurement of tooth length. IJDR 1989;1:58.

358. Stabholz A, Rotstein I, Torabinejad M. Effect of preflaring ontactile detection of the apical constriction. JOE 1995;21:92.

359. Ounsi HF, Haddad G. In vitro evaluation of the reliability ofthe Endex electronic apex locator. JOE 1998;24:120.

360. Clouse HR. Electronic methods of root canal treatment. GenDent 1991;39:132.

361. Anderson DM, Langeland K, Clark GE, Galich JW. Diagnosticcriteria for the treatment of caries-induced pulpitis.Bethesda (MD): Department of the Navy, Navy DentalResearch Institute; 1980. NDERI-PR 81-03.

362. Lin L, Shovlin F, Skribner J, Langeland K. Pulp biopsies fromthe teeth associated with periapical radiolucencies. JOE1984;10:436.

363. Langeland K. Tissue response to dental caries. Endod DentTraumatol 1987;3:149.

364. Lauper R, Lutz F, Barbakow F. An in vivo comparison of gradi-ent and absolute impedance electronic apex locators. JOE1996;22:260.

365. Fouad AF, Krell KV, McKendry DJ, et al. A clinical evaluationof five electronic root canal length measuring instruments.JOE 1990;16:446.

366. Aurelio JA, Nahmias Y, Gerstein H. A model for demonstratingan electronic canal length measuring device. JOE 1983;9:568.

367. Nahmias Y, Aurelio JA, Gerstein H. Expanded use of electron-ic canal length measuring devices. J Endod 1983;9:347.

368. Nahmias Y, Aurelio JA, Gerstein H. An in vitro model for eval-uation of electronic root canal measuring devices. JOE1987;13:209.

566 Endodontics

369. Donnelly JC. A simplified model to demonstrate the operationof electronic root canal measuring devices. JOE 1993;19:579.

370. Czerw RJ, Fulkerson MS, Donnelly JC. An in vitro test of a sim-plified model to demonstrate the operation of an electron-ic root canal measuring device. JOE 1994;20:605.

371. Kobayashi C. Electronic canal length measurement. Oral Surg1995;79:226.

372. Kovacevic M, Tamarut T. Influence of the concentration ofions and foramen diameter on the accuracy of electronicroot canal length measurement—an experimental study.JOE 1998;24:346.

373. Custer LE. Exact methods of locating the apical foramen. JNatl Dent Assoc 1918;5:815.

374. Suzuki K. Experimental study on ionophoresis. J Jpn Stomatol1942;16:411.

375. Gordon E. An instrument for measuring the length of rootcanals. Dent Pract XI 1960;3:86.

376. Sunada I. New method for measuring the length of the rootcanals. J Dent Res 1962;41:375.

377. Inoue N. Dental stethoscope measures root canal. Dent Surv1972;48:38.

378. Inoue N. An audiometric method for determining the lengthof root canals. J Can Dent Assoc 1973;39:630.

379. Inoue N. Dental stethoscope audiometric method for deter-mining root canal length. Medicon Neserland 1975;11:27.

380. Inoue N. A clinico-anatomical study for the determining rootcanal length by use of a novelty low-frequency oscillationdevice. Bull Tokyo Dent Coll 1977;18:71.

381. Ushiyama J. New principle and method for measuring the rootcanal length. JOE 1983;9:97.

382. Ushiyama J. Reliability and safety of the voltage gradientmethod of root canal measurement. JOE 1984;10:532.

383. Ushiyama J, Nakamura M, Nakamura Y. A clinical evaluationof voltage gradient method of measuring root canal length.JOE 1988;14:283.

384. Hasegawa K, Iitsuka M, Nihei M, Ohashi M. A new methodand apparatus for measuring root canal length. J NihonUniv Sch Dent 1986;28:117.

385. Saito T, Yamashita Y. Electronic determination of root canallength by a newly developed measuring device: influence ofthe diameter of apical foramen, the size of K-file and theroot canal irrigants. Dent Jpn 1990;27:65.

386. Yamashita Y. A study of a new electronic root canal measuringdevice using relative values of frequency response—influ-ences of the diameter of apical foramen, the size of elec-trode and the concentration of sodium hypochlorite. Jpn JConserv Dent 1990;33:547.

387. Kobayashi C, Okiji T, Kawashima N, et al. A basic study on theelectronic root canal length measurement. Part 3. Newlydesigned electronic root canal length measuring deviceusing division method. Jpn J Conserv Dent 1991;34:1442.

388. Kobayashi C, Suda H. New electronic canal measuring devicebased on the ratio method. JOE 1994;20:111.

389. Huang L. An experimental study of the principle of electronicroot canal measurement. JOE 1987;13:60.

390. Fouad AF, Krell KV. An in vitro comparison of five root canallength measuring instruments. JOE 1989;15:577.

391. Kaufman AY, Katz A. Reliability of Root ZX apex locator test-ed by an in vitro model [abstract]. JOE 1993;19:201.

392. Falchetta M, Castellucci A. In vitro evaluation and clinicalimpressions of the electronic apex locator Root ZX. G ItalEndod 1993;4:173.

Page 163: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 567

393. Kaufman AY, Fuchs M, Freidman S, et al. An in vitro model forpracticing the use of nickel titanium files with combinedautomated engine devices using a built-in apex locator. [Inpreparation].

394. Olson AK, Goerig AC, Cavataio RE, Luciano J. The ability ofthe radiograph to determine the location of the apical fora-men. Int Endod J 1991;24:28.

395. Chunn CB, Zardiackas LD, Menke RA. In vivo root canallength determination using the Forameter. JOE 1981;7:515.

396. Kaufman AY, Szajkis S, Niv D. The efficiency and reliability ofthe Dentometer for detecting root canal length. Oral Surg1989;67:573.

397. Walia HD, White PW, Kniaz A, Austin BP. In vivo evaluation offive apex locators [abstract]. JOE 1997;23:271.

398. Hemborough JH, Weine FS, Pisano JV, Eskoz N. Accuracy ofan electronic apex locator: a clinical evaluation in maxillarymolars. JOE 1993;19:242.

399. Pratten DH, McDonald NJ. Comparison of radiographic andelectronic working lengths. JOE 1996;22:173.

400. Kaufman AY, et al. Internat Endodon J 1997;30:403.401. Dunlap GA, Remeikis NA, BeGole EA, Rauschenberger CR. An

in vivo evaluation of the electronic apex locator that usesthe ratio method in vital and non-vital canals. JOE1998;24:48.

402. Murphy PM, Johnson JD, Hutter JW, Nicoll BK. Intracanal cal-ibration of the Root ZX electronic apex locator.[Unpublished].

403. McDonald NJ. The electronic determination of workinglength. Dent Clin North Amer. 1992;36:293.

404. Clinical Research Associates Newsletter. 1984;8.405. Kolnick J. Locating the elusive apex. NY Acad Gen Dent,

March, 1989.406. Pilot TF, Pitts DL. Determination of impedance changes at

varying frequencies in relation to root canal file positionand instrument. JOE 1997;23:719.

407. Ramil-Diwo M, Gerhardt T, Bremer M, Heidemann D. Clinicalapplication of three electronic apex locators comparedwith determining working length by radiographs[abstract]. Workshop on Measurement Techniques inEndodontics and Pulp Biology, Cumbria, England, June1992.

408. Himel VT, Cain C. An evaluation of two electronic apex locatorsin a dental student clinic. Quintessence Int 1993;24:803.

409. Cavelleri G, Menegazzi G, Gersosa R, et al. Electronic meas-urement of root canal length. G Ital Endod 1993;1:13.

410. Yamaoka M, Yamashita Y, Saito T. Electrical root canal meas-uring instrument based on a new principle [thesis]. Tokyo:Nihon Univ. School of Dentistry; 1989.

411. Osada Electric Co. Endex—electronic apex sensor, operator’smanual. Los Angeles: Osada Electric Co.; 1990.

412. White PW, Austin BP, Walia HD, Dhuru VB. Comparison ofaccuracy of four apex locators [abstract]. JOE 1996;22:216.

413. Fouad AF, Rivera EM, Krell KV. Accuracy of the Endex withvariations in canal irrigants and foramen size. JOE1993;19:63.

414. Felippe MCS, Soares IJ. In vitro evaluation of an audiometricdevice in locating the apical foramen of teeth. Endod DentTraumatol 1994;10:220.

415. Forsberg J. Radiographic distortion in endodontics [thesis].Bergen: Univ. of Bergen; 1987.

416. Frank AL, Torabinejad M. An in vivo evaluation of Endex elec-tronic apex locators. JOE 1993;19:177.

417. Mayeda DL, Simon JHS, Aimar DF, Finley K. In vivo measure-ment accuracy in vital and necrotic canals with Endex apexlocator. JOE 1993;19:545.

418. Arora RK, Gulabivala K. An in vivo evaluation of the Endexand RCM Mark II electronic apex locators in root canalswith different contents. Oral Surg 1995;79:497.

419. Kobayashi C, Matoba K, Suda H, Sunada I. New practicalmodel of the division method electronic root canal lengthmeasuring device. J Jpn Endod Assoc 1991;12:143.

420. Mezawa S, Komori S, Saito T. Clinical evaluation in electronicmeasuring of root canal length using several devices[abstract]. JOE 1992;18:184.

421. TOESCO Toei Electric Co. user’s manual—full auto root apexlocator JUSTWO TME-601. Tokyo: Toei Electric Co.,2002.

422. Kobayashi C. A basic study on electronic root canal lengthmeasurement. Part 6. A basic evaluation of the Sono-Explorer MK II Junior, Neosono MC and Justy. J Jpn EndoAssoc 1994;15:137.

423. Igarashi Y, Nii K, Jou YT, Kim S. Comparison of four electron-ic apex locators in determining canal length [abstract]. JOE1997;23:256.

424. Instruction Manual : Apex Finder A.F.A. (All Fluids Allowed)Model #7005: Orange (CA): Sybron Endo/AnalyticTechnology; 1997.

425. McDonald NJ, Pileggi R, Glickman GN, Varella C. An in vivoevaluation of third generation apex locators [abstract]. JDent Res 1999;219:136.

426. Kobayashi C, Suda H. A basic study on the electronic rootcanal length measurement. Part 4. A comparison of sixapex locators. Jpn J Conserv Dent 1993;36:185.

427. Christie WH, Peikoff MD, Hawrish CE. Clinical observationon a newly designed electronic apex locator. J Can DentAssoc 1993;59:765.

428. J. Morita Manufacturing Corp. Fully automatic root canallength measuring device, Root ZX, operation instructions.Kyoto: J. Morita Manufacturing Corp.; 1996.

429. Kobayashi C. The evolution of apex locating devices. AlphaOmegan 1997;90:21.

430. Czerw RJ, Fulkerson MS, Donnelly JC, Walmann JO. In vitroevaluation of the accuracy of several electronic apex loca-tors. JOE 1995;21:572.

431. Igarashi Y, Jabev J, Jou YT, Kim S. The effect of foramen mor-phology on apex locators [abstract]. JOE 1997;23:273.

432. Voss A, Markula-Liegau A. Accuracy of the ROOT ZX reading theapical constriction in vivo [abstract]. Int Endod J 1998;31:189.

433. Ounsi HF, Naaman A. In vitro evaluation of the reliability ofthe Root ZX electronic apex locator. Int Endod J1999;32:120.

434. Weiger R, John C, Geigle H, Lost C. Evaluation of two apex loca-tors—an in vitro study [abstract]. Int Endod J 1998;31:189.

435. Shabahang S, Goon WWY, Gluskin A. An in vivo evaluation ofthe Root ZX electronic apex locator. JOE 1996;22:616.

436. Vajrabhaya L, Tepmongkol P. Accuracy of an apex locator.Endod Dent Traumatol 1997;13:180.

437. Ambu E, Barboni MG, Vanelli M. Clinical and in vivo evalua-tion of the Root ZX electronic apex locator and its reliabil-ity. G Ital Endod 1997;4:192.

438. Pagavino G, Pale R, Baccetti T. A SEM study of in vivo accura-cy of the Root ZX electronic apex locator. JOE 1998;24:438.

439. Kobayashi C, Yoshioka T, Suda H. A new engine-driven canalpreparation system with electronic measuring capability.JOE 1997;23:751.

Page 164: Ch10: ENDODONTIC CAVITY PREPARATION

440. User’s guide for the Tri Auto ZX. Tustin (CA): J. Morita USAInc; Irvine, Ca.

441. Weathers AK, Wahl P. New endodontic handpiece takes guess-work out of endodontic preparation. Oral Health 1998;88:31.

442. Campbell D, Friedman S, Nguyen HQ, Kaufman A, Kelia S.Apical extent of rotary canal instrumentation with anapex-locating handpiece in vitro. Oral Surg 1998;85:319.

443. Grimberg F, Banegas G, Zmener O. Analisis preliminar del TriAuto ZX: una experiencia in vitro. Rev Asoc OdontolArgent 1998;86:533.

444. Campbell D, Friedman S. Clinical assessment of rotary canalinstrumentation with an apex locating handpiece[abstract]. JOE 1997;23:273.

445. Kobayashi C, Yoshioka T, Suda H. A new ultrasonic canalpreparation system with electronic monitoring of file tipposition. JOE 1996;22:489.

446. Kobayashi C, Yoshioka T, Aramaki S, et al. A basic study of theelectronic root canal length measurement. Part 5.Development of an ultrasonic canal preparation systemwith electronic canal length measurement. J Jpn EndodAssoc 1994;15:129.

447. Kaufman A. The Sono-Explorer as an auxillary device inendodontics. Isr J Dent Med 1976;25:27.

448. Fuss Z, Assoline LS, Kaufman AY. Determination of location ofroot perforations by electronic apex locators. Oral Surg1996;82:324.

449. Kaufman AY, Keila S. Conservative treatment of root perfora-tion using apex locator and thermatic compactor: casestudy of a new method. JOE 1989;15:267.

450. Kaufman AY, Fuss Z, Keila S, Waxenberg S. Reliability of dif-ferent electronic apex locators to detect root perforationsin vitro. Int Endod J 1997;30:403.

451. Knibbs PJ, Foreman PC, Smart ER. The use of an analog typeapex locator to assess the position of dentine pins. ClinPrev Dent 1989;11:22.

452. Hülsmann M, Pieper K. Use of an electronic apex locator inthe treatment of teeth with incomplete root formation.Endod Dent Traumatol 1989;5:238.

453. Wu NY, Shi JN, Huang LZ, Xu YY. Variables affecting electron-ic root canal measurement. Int Endod J 1992;25:88.

454. Baggett FJ, Mackie IC, Worthington HV. An investigation intothe measurement of working length of immature incisorteeth requiring endodontic treatment in children. BritDent J. 1996;181:96.

455. Katz A, Mass E, Kaufman AY. Electronic apex locator: a usefultool for root canal treatment in the primary dentition. JDent Child 1996;63:414.

456. Wooley LH, Woodworth J, Dobbs JL. A prelminary evaluationof the effects of electric pulp testers on dogs with artificialpacemakers. J Am Dent Assoc 1974;89:1099.

457. Beach CW, Bramwell JD, Hutter JW. Use of an electronic apexlocator on a cardiac pacemaker patient. JOE 1996;22:182.

458. Fouad AC, Reid LC. Effects of using apex locators on selectedendodontic treatment parameters [abstract]. JOE1998;24:271.

459. Stein TJ, Corcoran JF. Radiographic “working length” revisit-ed. Oral Surg 1992;74:796.

460. Schilder H. Cleaning and shaping the root canal. Dent ClinNorth Am 1974;18:269.

461. Buchanan LS. Paradigm shifts in cleaning and shaping. CalifDent Assoc J 1991;19:23.

568 Endodontics

462. Berg B. The endodontic management of multirooted teeth.Oral Surg 1953;6:399.

463. Saunders WP, Saunders EM. Effect of noncutting tippedinstruments on the quality of root canal preparation usinga modified double-flared technique. JOE 1992;18:32.

464. Buchanan LS. Management of the curved root canal. CalifDent Assoc J 1989;17:40.

465. Weine F. Endodontic therapy. St. Louis: CV Mosby; 1972.466. Martin H. A telescopic technique for endodontics. J District

Columbia Dent Soc 1974;49:12.467. Walton R. Histologic evaluation of different methods of

enlarging the pulp canal space. JOE 1976;2:304.468. Mullaney T. Instrument of finely curved canals. Dent Clin

North Am 1979;4:575.469. Weine FS, et al. The effect of preparation procedures on origi-

nal canal shape and on apical foramen shape. JOE1975;8:255.

470. Buchanan LS. File bending: essential for management ofcurved canals. Endodont Rep Spring/Summer, 1987. p.16.

471. Gutmann JL, Rakusin H. Perspectives on root canal obturationwith thermoplasticized injectable gutta-percha. Int EndodJ 1987;20:261.

472. Cuicchi B, et al. Comparison of curved canal shape using filingand rotational instrumentation techniques. Int Endod J1990;23:139.

473. Lim KC, Webber J. The effect of root canal preparation on theshape of the curved root canal. Int Endod J 1985;18:233.

474. Lim KC, Webber J. The validity of simulated root canals for theinvestigation of prepared root canal shape. Int Endod J1985;18:240.

475. Alodeh MHA, et al. Shaping of simulated root canals in resinblocks using the step-back technique with K-files manipu-lated in a simple in/out filing motion. Int Endod J1989;22:107.

476. Vessey RA. The effect of filing vs. reaming on the shape of theprepared root canal. Oral Surg 1969;27:543.

477. Jungmann CL, Uchin RA, Bucher JF. Effect of instrumentationon the shape of the root canal. JOE 1975;1:66.

478. Haga CS. Microscopic measurements of root canal prepara-tions following instrumentation. J Br Endod Soc 1969;2:41.

479. Nygaard-Østby B. Chelation in root canal therapy. SartryckOdontol Tidsk 1957;65:1.

480. Patterson SS. In vitro and in vivo studies of the effect of the dis-odium salt of ethylenediamine tetraacetate on humandentin and its endodontic implications. Oral Surg1963;16:83.

481. Fraser JG. Chelating agents: their softening effect on root canaldentin. Oral Surg 1974;37:803.

482. Fraser JG, Laws AL. Chelating agents: their effect on perme-ability of root canal dentin. Oral Surg 1976;41:534.

483. Selden HS. The role of a dental microscope in improving non-surgical treatment of “calcified” canals. Oral Surg1989;68:93.

484. McSpadden J. Use of the Infinity Scope. Advanced EndodonticConcepts; 1991.

485. Gold SI. Root canal calcification associated with prednisonetherapy: a case report. J Am Dent Assoc 1989;119:523.

486. Marshall FJ, Pappin J. A crown-down pressureless-preparationroot canal enlargement technique. Technique manual.Portland (OR): Oregon Health Sciences Univ.; 1980.

487. Leeb JI. Canal orifice enlargement as related to biomechanicalpreparation. JOE 1983;9:463.

Page 165: Ch10: ENDODONTIC CAVITY PREPARATION

Endodontic Cavity Preparation 569

488. Weine FS. Endodontic therapy. 3rd ed. St. Louis: CV Mosby;1981.

489. Morgan LF, Montgomery S. An evaluation of the crown-downpressureless technique. JOE 1984;10:491.

490. Ruiz-Hubard EE, et al. A quantitative assessment of canaldebris forced periradicularly during root canal instrumen-tation using two different techniques. JOE 1987;12:554.

491. Southard DW, et al. Instrumentation of curved molar rootcanals with the Roane technique. JOE 1987;10:479.

492. Bachman CA, et al. A radiographic comparison of two rootcanal instrumentation techniques. JOE 1992;18:19.

493. Roane JB. Presentation, American Association of EndodonticsAnnual Meeting, Las Vegas, Nevada April 1990.

494. Sabala CL, Roane JB, et al. Instrumentation of curved canalsusing a modified typed instrument: a comparison study.JOE 1988;14:59.

495. McKendry DJ. A histologic evaluation of apical root canaldebridement comparing two endodontic instrument tech-niques [abstract]. JOE 1988;14:198.

496. McKendry DJ. Comparison of balanced forces, endosonic andstep-back filing instrumentation techniques: quantificationof extruded apical debris. JOE 1990;16:24.

497. Swindle RB, et al. Effect of coronal-radicular flaring on apicaltransportation. JOE 1991;17:147.

498. Charles TJ, Charles JE. The balanced force concept of instrumen-tation of curved canals revisited. Int Endod J 1998;31:166.

499. Alacam T. Scanning electron microscope study comparing theefficacy of endodontic irrigating systems. Int Endod J1987;20:287.

500. Jahde EM, et al. A comparison of short-term periradicularresponses to hand and ultrasonic overextension duringroot canal instrumentation in the Macaca fascicularis mon-key. JOE 1987;13:388.

501. Mungel C, et al. The efficacy of step-down procedures duringendosonic instrumentation. JOE 1991;17:111.

502. Glosson CR, Haller RH, Dove SB, del Rio CE. A comparison ofroot canal preparations using NiTi engine-driven, and K-Flex endodontic instruments. JOE 1995;21:146.

503. Luiten D, Morgan L, Baumgartner C, Marshall JG.Comparison of four instrumentation techniques on apicalcanal transportation. JOE 1995;21:26.

504. Weine FS. The use of non-ISO-tapered instruments for canalflaring. Compend Dent Educ 1996;17:651.

505. Bryant ST, Dummer PMH, Pitoni C, et al. Shaping ability of.04 and .06 taper ProFile rotary nickel-titanium instru-ments in simulated root canals. Int Endod J 1999;32:155.

506. Bryant ST, Thompson SA, Al-Omari MA, Dummer PMH.Shaping ability of Profile rotary nickel titanium instru-ments with ISO sized tips in simulated root canals. Part 1.Int Endod J 1998;31:275.

507. Thompson SA, Dummer PMH. Shaping ability of QuantecSeries 2000 rotary nickel-titanium instruments in simulat-ed root canals: part 1. Int Endod J 1998;31:259.

508. Thompson SA, Dummer PMH. Shaping ability of LightSpeedrotary nickel-titanium instruments in simulated rootcanals: part 1, Int Endod J 1997;23:698.

509. Thompson SA, Dummer PMH. Shaping ability of Profile .04taper Series 29 rotary nickel-titanium instruments in sim-ulated root canals. Part 1. Int Endod J 1997;30:1.

510. Thompson SA, Dummer PMH. Shaping ability of Profile .04taper Series 29 rotary nickel-titanium instruments in sim-ulated root canals. Part II. Int Endod J 1997;30:8.

511. Serene TP, Adams JD, Saxena A. Nickel-titanium instruments:applications in endodontics. St. Louis: IshiyakuEuroAmerica; 1994.

512. Zuolo ML, Walton RE. Instrument deterioration with usage:nickel-titanium versus stainless steel. Quintessence Int1997;28:397.

513. Rowan M, Nicholls J, Steiner J. Torsional properties of stainlesssteel and nickel-titanium files. JOE 1996;22:341.

514. Pruett JP, Clement DJ, Carnes DL Jr. Cyclic fatigue testing ofnickel-titanium endodontic instruments. JOE 1997;23:77.

515. Kavanaugh D, Lumley PJ. An in vitro evaluation of canalpreparation using Profile .04 and .06 taper instruments.Endod Dent Traumatol 1988;14:16.

516. Gabel WP, Hoen M, Steinman HR, et al. Effect of rotationalspeed on nickel-titanium file distortion. JOE 1999;25:752.

517. Blum JY, Machtou P, Micallef JP. Location of contact areas onrotary Profile instruments in relationship to the forcesdeveloped during mechanical preparation on extractedteeth. Int Endod J 1999;32:108.

518. Schwartz FS, McSpadden JT. The Quantec rotary nickel titani-um instrumentation system. Endod Pract 1999;2:14.

519. Tharuni SL, Parameswaran A, Sukumaran VG. A comparisonof canal preparation using the K-file and LightSpeed inresin blocks. JOE 1996;22:474.

520. Knowles KI, Ibarolla JL, Christiansen RK. Assessing apicaldeformation and transportation following the use ofLightSpeed root-canal instruments. Int Endod J1996;29:113.

521. Poulsen WB, Dove SG, del Rio CE. Effect of nickel-titaniumengine-driven instrument rotational speed on root canalmorphology. JOE 1995;21:609.

522. Rapisarda E, Bonaccorso A, Tripi TR, Guido G. Effect of steril-ization on the cutting efficiency of rotary nickel-titaniumendodontic files. Oral Surg 1999;88:343.

523. Stern RH, Sognnaes RF. Laser beam effect on dental hard tis-sues [abstract]. J Dent Res 1964;43:873.

524. Wigdor HA, Walsh JT, Featherstone JDB, et al. Lasers in den-tistry. Laser Surg Med 1995;16:103.

525. Neev J, Liaw LL, Stabholz A, et al. Tissue alteration and ther-mal characteristics of excimer laser interaction with dentin.SPIE Proc 1992;1643:386.

526. Neev J, Stabholz A, Liaw LL, et al. Scanning electronmicroscopy and thermal characteristics of dentin ablatedby a short pulsed XeCl excimer laser: Laser Surg Med1993;12:353.

527. Dederich DN, Zakariasen KL, Tulip J. Scanning electronmicroscopic analysis of canal wall dentin. JOE 1984;10:428.

528. Weichman JA, Johnson FM. Laser use in endodontics. A pre-liminary investigation. Oral Surg 1971;31:416.

529. Weichman JA, Johnson FM, Nitta LK. Laser use in endodon-tics. Part II. Oral Surg 1972;34:828.

530. Stabholz A. Lasers in endodontics. In: Proceedings 6thInternational Congress on Lasers in Dentistry, Maui,Hawaii, July 28–31, 1998. p. 7.

531. Zackariasen KL, Dederich DN, Tulip J, et al. Bacterial action ofcarbon dioxide laser irradiation in experimental dentalroot canals. Can J Microbiol 1986;32:942.

532. Levy G. Cleaning and shaping the root canal with a Nd:YAGlaser beam: a comparative study. JOE 1992;18:123.

533. Moshonov J, Sion A, Kasirer J, et al. Efficacy of argon laser irra-diation in removing intracanal debris. Oral Surg1995;79:221.

Page 166: Ch10: ENDODONTIC CAVITY PREPARATION

534. Pini R, Salimbeni R, Vannini M, Barone R. Laser dentistry: anew application of excimer in root canal therapy. LaserSurg Med 1989;9:352.

535. Nuebler-Moritz M, Gutknecht N, Sailer HF, Hering P, Prettl W.Laboratory investigation of the efficacy of holmium:YAGlaser irradiation in removing intracanal debris. In: WigdorHA, Featherstone JDB, Rechmann P, editors. Lasers in den-tistry III. Proc SPIE 1997;2973:150.

536. Moritz A, Gutknecht N, Goharkhay K, et al. In vitro irradia-tion of infected root canals with a diode laser: results ofmicrobiologic, infrared spectrometric, and stain penetra-tion examinations. Quintessence Int 1997;28:205.

537. Mehl A, Folwaczny M, Haffner C, Hickel R. Bactericidal effectsof 2.94 µm Er:YAG laser radiation in dental root canals.JOE 1999;25:490.

538. Bahcall J, Howard HA, Miserendino L, Walia H. Preliminaryinvestigation of the histological effects of laser endodontictreatment on the periradicular tissues in dogs. JOE1992;18:47.

539. Goodis HE, White JM, Marshall SJ, Marshall GW. Scanning elec-tron microscopic examination of intracanal wall dentin: ver-sus laser treatment. Scanning Microsc 1993;7:979.

540. Liu HC, Lin CP, Lan WH. Sealing depth of Nd:YAG laser onhuman dentinal tubules. JOE 1997;23:691.

541. Koba K, Kimura Y, Matsumoto K, et al. A histopathologicalstudy of the morphological changes at the apical seat andin the periapical region after irradiation with a pulsedNd:YAG laser. Int Endod J 1998;31:415.

542. Koba K, Kimura Y, Matsumoto K, et al. A histological study ofthe effects of pulsed Nd:YAG laser irradiation on infectedroot canal in dogs. JOE 1999;25:151.

543. Gutknecht N, Kaiser F, Hassan A, Lampert F. Long-term clini-cal evaluation of endodontically treated teeth by Nd:YAGlasers. J Clin Laser Med Surg 1996;14(1):7.

544. Zhang C, Kimura Y, Matsumoto K, et al. Effects of pulsed lasedNd:YAG laser irradiation on root canal wall dentin withdifferent lasers initiators. JOE 1998;24:352.

545. Cecchini SCM, Zezell DM, Bachmann L, et al. Evaluation oftwo laser systems for intracanal irradiation. In:Featherstone JDB, Rechmann P, Fried D, editors. Lasers indentistry V. Proc SPIE 1999;3593:31.

546. Takeda FH, Harashima T, Kimura Y, Matsumoto K. The mor-phological study of root canal walls with Er:YAG laser irra-diation in removing debris and smear layer on root canalwalls. JOE 1998;24:548.

547. Takeda FH, Harashima T, Eto JN, et al. Effect of Er:YAG lasertreatment on the root canal walls of human teeth: an SEMstudy. Endod Dent Traumatol 1998;14:270.

548. Harashima T, Takeda FH, Kimura EJN, Matsumoto K. Effect ofNd: YAG laser irradiation for removal of intercanal debrisand smear layer extracted human teeth. Jour of Clin LaserMed and Surg. 1997;15:131.

570 Endodontics

549. Hibst R, Stock K, Gall R, Keller U. ErYAG laser for endodonticsefficiency and safety. In: Wigdor H, Featherstone JDB,Rechmann P, editors. Lasers in dentistry II. Proc SPIE1997;3192:14.

550. Harashima T, Takeda FH, Kimura EJN, Matsumoto K. Effect ofargon laser irradiation on instrumented root canal walls.Endod Dent Traumatol 1998;14:26.

551. Stabholz A, Neev J, Liaw LHL, et al. Sealing of human dentinaltubules by Xe-Cl 308-nm excimer laser. JOE 1993;19:267.

552. Hennig T, Rechmann P, Hadding U. Influences of 2nd har-monic alexandrite laser radiation on bacteria. In:Proceedings 6th International Congress on Lasers inDentistry, Maui, Hawaii, July 28–31, 1998. p. 225.

553. White JM, Goodis HE, Cohen JN. Bacterial reduction of con-taminated dentin by Nd:YAG laser [abstract]. J Dent Res1991;70:412.

554. Stabholz A, Kettering J, Neev J, Torabinejad M. Effects of theXeCl excimer laser on Streptococcus mutans. JOE1993;19:232.

555. Gutknecht N, Moritz A, Conrads G, et al. Bacterial effect ofNd:YAG laser in in vitro root canals. J Clin Laser Med Surg1996;14:77.

556. Gutknecht N, Nuebler-Moritz M, Burghardt SF, Lampert F.The efficiency of root canal disinfection using a holmi-um:yttrium-alumimium-garnet laser in vitro. J Clin LaserMed Surg 1997;15:75.

557. Gouw-Soares SC. Avaliacao bacteriana em dentina radicularcontaminada irradiada com laser de Ho:YAG. Estudo invitro [thesis]. Sao Paulo (Brazil): Faculdade deOdontologia da Universidade de Sao Paulo; 1998.

558. Lussi A, Nussbacher U, Grosrey J. A novel non-instrumentedtechnique of cleansing the root canal system. JOE1993;19:549.

559. Lussi A, Portman P, Nussbacher U, et al. Comparison of twodevices for root canal cleansing by the noninstrumentationtechnology. JOE 1999;25:9.

560. McQuillen JH. Dr. Maynard’s method of extirpating the pulp.Dent Cosmos 1860;1:312.

561. Bohannan HM, Abrams L. Intentional vital pulp extirpationfor prosthesis. J Prosthet Dent 1961;11:781.

562. McQuillen JH. Review of dental literature and art: “Who firstfilled nerve cavities?” Dent Cosmos 1862;3:556.

563. Stromberg T. Wound healing after total pulpectomy in dogs.Odontol Revy 1969;20:147.

564. Pitt Ford TR. Vital pulpectomy—an unpredictable procedure.Int Endod J 1982;15:121.

565. Delivarris PD, Fan VSC. The localization of blood-borne bac-teria in instrumented unfilled and overinstrumentedcanals. JOE 1984;10:521.

566. Hasselgren G, Reit C. Emergency pulpotomy: pain relievingeffect with and without the use of sedative dressing. JOE1989;15:254.