74
This form shall be completed and submitted with Application Documents Owners Name P.I.D. Project Address Design Professional Phone Fax Contractor Phone Fax Applicable Codes Manufacturer / FL Product Approval / NOA # Building Code Florida Building Code Doors / SGD Mechanical Code Florida Building Code Windows Plumbing Code Florida Building Code Overhead Doors Electrical Code NFPA 70 / NEC 2011 Mitered Glass Accessibility Code Florida Building Code Shutters Energy Code Florida Building Code 2017 Residential Volume 2017 Residential Volume 2017 Residential Volume FACBC 2017 Residential Energy Efficiency 2017 Roof Coverings Soffit Method of Design per R301 / Residential Volume ASCE 7 10 AISI (COFS/PM) ICC 600 MAF Guide Other FBC 2010 / Residential Volume IV V ( circle one ) Other m.p.h. R301.2 (4) Yes No Exposure B or C (circle one) feet psf Section R301.4 / R301.5 / R301.6 psf p.s.f psf p.s.f p.s.f p.s.f SEE PLAN FOR ACTUAL Please Show Design Pressure for Worst Case ONLY Components and Cladding Design Pressures: Z1 p.s.f. Z3 p.s.f. Z5 p.s.f. Z2 p.s.f. Z4 p.s.f. a= edge distance Misc. Notes Area Tabulation Living sf / Conditioned Space Garage sf Lanai sf Entry sf Storage sf Other sf Signature Date Architect / Engineer Seal Residential Data Summary Worksheet / Revised / mar1 3 RESIDENTIAL DATA SUMMARY WORKSHEET PRESSURE DESIGN LOADING Total square footage Doors Mean Roof Height Windows Dead Load Roof Design Live Load City of 4 , Fl. 3428 Phone (941) 4 Fax (941) Email: @ci Inspections (941) 4 Importance Factor Wind Debris Area Structural Forces Dead Load Floor Design Sentricon Bait AF&PA (WFCM) WINDOW & DOOR WIND Construction Type Design Wind Speed Garage Doors I certify to the best of my knowledge and belief, these plans and specifications have been designed to comply with the structural portion of the Building Code for wind and gravity loads as amended and enforced by the permitting jurisdiction. Live Load

City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

This form shall be completed and submitted with Application Documents

Owners Name P.I.D.

Project Address

Design Professional Phone  Fax

Contractor Phone  Fax

Applicable Codes Manufacturer / FL Product Approval / NOA #

Building Code Florida Building Code Doors / SGD

Mechanical Code Florida Building Code Windows

Plumbing Code Florida Building Code Overhead Doors

Electrical Code NFPA 70 / NEC 2011 Mitered Glass

Accessibility Code Florida Building Code Shutters

Energy Code Florida Building Code

 2017 Residential  Volume

 2017 Residential  Volume

 2017 Residential  Volume

 FACBC    2017 Residential Energy 

Efficiency 2017Roof  Coverings

Soffit

  Method of Design per R301 / Residential Volume

ASCE 7 ‐ 10 AISI (COFS/PM) ICC 600

MAF Guide Other  

FBC 2010 / Residential Volume

IV V ( circle one ) Other 

m.p.h. R301.2 (4)

Yes No Exposure   B  or  C  (circle one) feet

psf

Section R301.4 / R301.5 / R301.6 psf

p.s.f psfp.s.f

p.s.fp.s.f

SEE PLAN FOR ACTUAL Please Show Design Pressure for Worst Case ONLY

  Components and Cladding Design Pressures:

 Z1                                                     p.s.f. Z3 p.s.f. Z5   p.s.f.

 Z2                                                     p.s.f. Z4 p.s.f. a= edge distance

  Misc. Notes Area TabulationLiving  sf / Conditioned SpaceGarage  sfLanai  sfEntry  sfStorage  sfOther  sf

  Signature   Date  Architect / Engineer

Seal Residential   Data Summary Worksheet / Revised /  mar 13

RESIDENTIAL DATA SUMMARY WORKSHEET

PRESSURE DESIGN LOADING

Total square footage

Doors  

Mean Roof Height  

Windows  

Dead Load   Roof Design

Live Load   

City of ±ŜƴƛŎŜ

4лм ²Φ ±ŜƴƛŎŜ !ǾŜƴdzŜ ±ŜƴƛŎŜ, Fl. 3428р

Phone (941) 4ус‐нснс    Fax (941) пусπнппу    Email: tŜNJƳƛǘǎhƴƭƛƴŜ@ciΦǾŜƴƛŎŜΦŦƭΦdzǎ    Inspections (941) 4уо‐рфлт

.dzƛƭŘƛƴƎ 5ŜLJŀNJǘƳŜƴǘ

Importance Factor  

Wind Debris Area  

 Structural Forces 

Dead Load   Floor Design

Sentricon Bait

AF&PA (WFCM)

WINDOW & DOOR WIND

  Construction Type 

Design Wind Speed   

Garage Doors  

  I certify to the best of my knowledge and belief, these plans and specifications have been designed to comply with the  structural portion of the Building Code for wind and gravity loads as amended and enforced by the permitting jurisdiction.

Live Load   

kbutterwor
Typewritten Text
LJDomzalski
Highlight
LJDomzalski
Highlight
Ralph
Seal
Ralph
Signature Statement Narrow
Page 2: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

10'-4" Tray

10'-4" Tray

10'-4" Tray

10'-4" Tray

EXPOSED TO WIND

EXPOSED TO WINDU:2263

U:1335

U:1152

R:1

2,3

87

U:5

21

2R

:887

9U

:364

5

U:1

09

7U

:10

97

AA

AA

AA

AA

AA

A*

B

A01

A02

A03

A04

A05

A06

A07

A08

HJ10

HJ1

0A

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

EJ7

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5A

CJ1

CJ3

CJ5A

A10

A10

A10

A10

A10

A10

A13

A13

A12

A12

A12

A12

A13

A13

A13

A13A11

A14

A15

A16

A17

A18

A19

A20

B03

B04

B05

HJ10

HJ1

0

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3C

CJ5C

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ3A

D5

D6

HJ8

HJ8

CJ1

CJ3

CJ1

CJ3

CJ1

CJ3

CJ1

CJ3

D7

D8

D9

E1

E2

HJ8A

CJ1

CJ3B

CJ1

CJ3

HJ8

A

CJ1

CJ3B

CJ1

CJ3

F1

F2

HJ1

0

HJ10

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

EJ7

EJ7

EJ7

CJ1

CJ3

CJ5

CJ1

CJ3

CJ5

EJ7

F3

V6

V1

0

V1

4

V1

8

V2

2

EJ7A(4)

EJ5(3)

EJ5A(4)

70-08-00

9-04-00

80-00-00

21-02-005-10-0013-00-00

40-00-00

5-00-00

6-00-00

2-08-0010-00-00

2-08-00

11-06-00

13-00-00 12-00-00

7-02-00

17-00-00

2-08-00 7-04-00

3-09-08

5-09-08

2-00-00

1-07-00

2-00-00

2-00-00

3-09-08

2-00-00

2-00-00

2-00-00

1-01-00

2-00-00

2-00-00

21-08-004-10-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

1-04-00

1-10-08

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

5-09-08

2-00-00

1-06-08

5-08

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

2-00-00

23-04-00

53-10-00

77-02-00

1-04-00

10-00-00

10-00-00

50-00-00

15-04-0024-08-00

MODEL

10

G

THA422

SIMPSON CONNECTOR SCHEDULE

1550J

1415 / 2245

ACCESSORIES

B

4310 / 4680

0

1/2" NUTS

0

M

0

IDUPLIFT

SDS 1/4" x 3"

E

HTU26

M

L

BOLTS

7460

MODEL

0

MODEL

D

4095

E

0

H

5230

3x8 NAIL ON PLATES

0

SDS 1/4" x 6"

1/2" WASHERS

MODEL

0

QTY

MISCELLANEOUS

E

0

1530 / 3485

UPLIFT

HGUS28-3

0

HGUS26-2

C 0 D DHTU28-2 1530 / 34854310 / 4680

B0 HTU28 1235 / 21403895 / 4680 B

3235

H

F7460F

HGUS28-3

HGUS28-2

3235

0

H0 7460

SCREWS

QTY

C

HTU26-2

895

2790

QTY

C

HGUS210-4

2 PLY TYP.

3x8 NAIL ON PLATES

1

1/2" WASHERS

FLOOR TRUSS

3235

HTU26-2

L

1 PLY TYP.

N

A*A* 490895LUS240

HGUS26-2

B

N/A

HTU28

ID

HHUS46

0

A

SDS 1/4" x 3"

2155HGUS26-3

1250 / 1555

QTY MODEL

QTY

H

3200 / 3600

ROOF

HGUS26-3

G

MODEL

1/2" x 8" CARR. BOLTS

HGUS28-2

HTU28-2

0

1235 / 2140

MODEL

HGUS210-4 J

QTY

2155

N/A

THA426

F

490

2155

3200 / 3600

N/A

3600

0

A

O

1415 / 2245

G

5320

L

SYMBOL

1250 / 1555

0

A

MODEL

5320

9100

QTY

HU26

3600

A*

0

0

BOLTS

7460

1515 / 2175

C

9100

A*

HTU26-2

J

D

HTU26

3235

SEAT PLATES

0

SYMBOL

HHUS46 SDS 1/4" x 4-1/2"

1/2" NUTS

FLOOR

1515 / 2175

QTY

ROOF TRUSS

1/2" x 8" CARR. BOLTS

2435 / 2245

SDS 1/4" x 6"

SEAT PLATES

FLOOR TRUSS

HU26

HTU26

0

FLOOR TYP.

O

G

3895 / 4680

E

ACCESSORIES

SCREWS

A

ROOF TRUSS

A

5230

J

C

2155

F

THAC422

4095

SDS 1/4" x 4-1/2"

N

895 4901

5

6-3

/16"

2x4 T.C. MIN.

14 1/2"CANT.

12

TYP. ROOF TRUSS END DETAIL

8" BRG.

N.T.S.

TILE ROOF

Hatch Legend

13'-11" BEARING HEIGHT

9'-4" BEARING HEIGHT

REVISIONS

No. DATE NOTES BY

CAUTION!!!

DO NOT ATTEMPT TO ERECT TRUSSESWITHOUT REFERRING TO THE ENGINEERINGDRAWINGS AND BSCI-B1 SUMMARY SHEETS.

ALL PERMANENT BRACING MUST BE INPLACE PRIOR TO LOADING TRUSSES. (ie.SHEATHING, SHINGLES, ETC.)

ALL INTERIOR BEARING WALLS MUST BE INPLACE PRIOR TO INSTALLING TRUSSES.

REFER TO FINAL ENGINEERING SHEETS FORTHE FOLLOWING.

1) NUMBER OF GIRDER PLIES AND NAILINGSCHEDULE.

2) BEARING BLOCK REQUIREMENTS.

3) SCAB DETAILS (IF REQUIRED)

4) UPLIFT AND GRAVITY REACTIONS.

WARNINGBACK CHARGES WILL NOT BEACCEPTED REGARDLESS OF FAULTWITHOUT PRIOR NOTIFICATION BYCUSTOMER WITHIN 48 HOURS ANDINVESTIGATION BY Builders FirstSource.NO EXECPTIONS.

THE GENERAL CONTRACTOR ISRESPONSIBLE FOR ALL CONNECTIONSOTHER THAN TRUSS TO TRUSS, GABLESHEAR WALL, AND CONNECTIONS.TEMPORAY AND PERMANENT BRACING,AND CEILING AND ROOF DIAPHRAMCONNECTIONS.

6850 Taylor Road Punta Gorda, Fl. 33950Phone: 941-575-2250 / Fax:941-575-0319

IMPORTANT

This Drawing Must Be Approved And ReturnedBefore Fabrication Will Begin. For Your Protection

Check All Dimensions And Conditions Prior ToApproval Of Plan.

SIGNATURE BELOW INDICATES ALL NOTESAND DIMENSIONS HAVE BEEN ACCEPTED.

By _________________________Date___________

NOTES:1) ALL DIMENSIONS ARE FEET-INCHES-SIXTEENTHS.2) DO NOT CUT OR ALTER TRUSSES IN ANY WAY.3) ALL REACTIONS ARE UNDER 5000 LBS. UNLESS NOTE OTHERWISE.4) ALL UPLIFTS ARE UNDER 1000 LBS. UNLESS NOTED OTHERWISE.5) FRAMING REQUIRED BELOW TRUSSES TO GET DESIRED CEILING CONDITIONS.6) ONLY TRUSS TO TRUSS CONNECTIONS SUPPLIED W/ TRUSS PACKAGE.

DATE DRAWN 8/11/2020

DATE PRINTED 8/11/2020

MASTERJOB No.

WIND LOAD 160 MPH

EXPOSURE CATEGORY C

OCCUPANCY CATEGORY II

IMPORTANCE FACTOR 1.0

WIND DURATION FACTOR 1.60

OPENING CONDITIONS ENCLOSED

GENERAL TRUSS ENGINEERING CRITERIA & DESIGN LOADS

TRUSSES HAVE BEEN DESIGNED FOR A 10.0 PSF BOTTOM CHORDLIVE LOAD NONCONCURRENT WITH ANY OTHER LIVE LOADS

DESIGN CODE FBC2017/TPI2014

WIND CODE MWFRS (Directional)/C-C HYBRID WIND ASCE 7-10

TRUSS LOADING ROOF

TCLL 20 PSF

TCDL 20 PSF

BCLL 0 PSF

BCDL 10 PSF

TOTAL 50 PSF

DURATION 1.25

TCDL / TO RESIST UPLIFT 5 PSF

BCDL / TO RESIST UPLIFT 5 PSF

TRUSS LOADING

ROOF PITCH 5/12

CEILING PITCH FLAT

TOP CHORD SIZE 2 x 4 MIN.

BOTTOM CHORD SIZE 2 x 4 MIN.

OVERHANG LENGTH N/A

CANTILEVER 14 1/2"

END CUT PLUMB

FLOOR TRUSS SPACING N/A

ROOF TRUSS SPACING 24"

ROOF PITCH

BUILDER DR Horton

PROJECT 2221 M 160 C 3-CAR RH

MODEL 2221

ADDRESS --

CITY, STATE --, FL.

LOT --

COUNTY --

DRAWN BY D.W.

ENG. BY D.W.

Ralph
Shop Draw X
Page 3: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

A-1 M

3/16" = 1'-0"

ELEVATIONS

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

AutoCAD SHX Text
%%U%%ORIGHT SIDE ELEVATION: "M"%%O
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
4'-0" X 12"
AutoCAD SHX Text
25 SH
AutoCAD SHX Text
35 SH
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
F.G.
AutoCAD SHX Text
F.G.
AutoCAD SHX Text
F.G.
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
FIXED GLASS
AutoCAD SHX Text
CANTILEVER TRUSS
AutoCAD SHX Text
B1
AutoCAD SHX Text
B3
AutoCAD SHX Text
B6
AutoCAD SHX Text
B5
AutoCAD SHX Text
A1
AutoCAD SHX Text
B7
AutoCAD SHX Text
WATER TABLE
AutoCAD SHX Text
BANDING DETAILS
AutoCAD SHX Text
E2
AutoCAD SHX Text
E1
AutoCAD SHX Text
D1
AutoCAD SHX Text
D2
AutoCAD SHX Text
C3
AutoCAD SHX Text
D5
AutoCAD SHX Text
A3
AutoCAD SHX Text
A4
AutoCAD SHX Text
C2
AutoCAD SHX Text
A2
AutoCAD SHX Text
C1
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
ALLOW 2" FOR HURRICANE SHUTTER ATTACHMENT
AutoCAD SHX Text
%%U%%OTYPICAL WINDOW BANDING DETAIL%%O
AutoCAD SHX Text
%%U%%OSOFFIT DETAIL%%O
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
CANTILEVER
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
2X6 MIN. SUB FASCIA
AutoCAD SHX Text
FLASHING AND DRIP EDGE PER NOTES IN TABLE 3 ON A-6
AutoCAD SHX Text
@ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
@ 9'-4" A.F.F.
AutoCAD SHX Text
TO FINISH FLOOR
AutoCAD SHX Text
@ 0'-0" A.F.F.
AutoCAD SHX Text
@ 0'-0" A.F.F.
AutoCAD SHX Text
%%U%%OFRONT ELEVATION: "M"%%O
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
TO GRADE
AutoCAD SHX Text
26 SH
AutoCAD SHX Text
16'-0" X 8'-0" O.H. GARAGE DOOR
AutoCAD SHX Text
W/ SIDE LITE
AutoCAD SHX Text
3080 FRONT ENTRY DR.
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
CANTILEVER
AutoCAD SHX Text
TRUSS
AutoCAD SHX Text
CANTILEVER
AutoCAD SHX Text
TRUSS
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
@ 13'-11" A.F.F.
AutoCAD SHX Text
TRUSS MFR TO SET HEEL
AutoCAD SHX Text
HEIGHT AS NEEDED TO PLANE
AutoCAD SHX Text
OUT WITH MAIN ROOF BEYOND
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
A4
AutoCAD SHX Text
8'-0" X 8'-0" O.H. GARAGE DOOR
AutoCAD SHX Text
%%U%%OREAR ELEVATION: "M" %%O
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
35 SH
AutoCAD SHX Text
3-4080 SL. GL. DR.
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
2-35 SH
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
CANTILEVER TRUSS
AutoCAD SHX Text
%%U%%OLEFT SIDE ELEVATION: "M"%%O
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
TYP.
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
ELEV @ 9'-4" A.F.F.
AutoCAD SHX Text
TOP OF FINISH FLOOR
AutoCAD SHX Text
ELEV @ 0'-0" A.F.F.
AutoCAD SHX Text
TOP OF BOND BEAM
AutoCAD SHX Text
34 SH
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
CANTILEVER TRUSS
AutoCAD SHX Text
12
AutoCAD SHX Text
5
AutoCAD SHX Text
24"X24"
AutoCAD SHX Text
F.G.
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
AutoCAD SHX Text
TOP OF WALL 60"
AutoCAD SHX Text
TILE ROOF
AutoCAD SHX Text
TILE ROOF
AutoCAD SHX Text
TILE ROOF
AutoCAD SHX Text
TILE ROOF
Page 4: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

3/16" = 1'-0"

A-2M

SLAB & PLUMBING

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

AutoCAD SHX Text
%%USIDE ELEVATION
AutoCAD SHX Text
%%UFRONT ELEVATION
AutoCAD SHX Text
%%UWATER CLOSET CLEARANCE DETAIL
AutoCAD SHX Text
%%USIDE ELEVATION
AutoCAD SHX Text
%%UFRONT ELEVATION
AutoCAD SHX Text
%%UVANITY SINK CLEARANCE DETAIL
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
FAUCET
AutoCAD SHX Text
FAUCET
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
KICK PLATE
AutoCAD SHX Text
SLOPED CEILING
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
6" X 12" RECESS
AutoCAD SHX Text
SEE DETAIL
AutoCAD SHX Text
PROVIDE 1/4" WATER
AutoCAD SHX Text
LINE @ REF. SPACE
AutoCAD SHX Text
FOR ICE MAKER
AutoCAD SHX Text
RECESS TILE
AutoCAD SHX Text
SHWR 3 1/2"
AutoCAD SHX Text
5'-0" TUB
AutoCAD SHX Text
ELEV @ -0'-4"
AutoCAD SHX Text
PAVERS BY OTHERS
AutoCAD SHX Text
PAVERS BY OTHERS
AutoCAD SHX Text
5'-0" TUB
AutoCAD SHX Text
%%U%%OSLAB & PLUMBING PLAN:%%O
AutoCAD SHX Text
SCALE: 3/16"=1'-0"
AutoCAD SHX Text
16'-0" X 8'-0" O.H. GARAGE DR.
AutoCAD SHX Text
ELEVATION @ 0'-0"
AutoCAD SHX Text
4" SLAB W/ 2,500 P.S.I. CONC. W/ 6X6 #10/10 W.W.M. REINFORCING OVER 6 MIL. VISQUEEN BARRIER ON MECHANICALLY COMPACTED FILL @ 95%.
AutoCAD SHX Text
LOWEST POINT OF GARAGE FLOOR SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP
AutoCAD SHX Text
THE FINISH FLOOR SLAB SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP PLUS 1'-0" FREEBOARD PER FBCR R322.2.1 SEE SITE PLAN BY OTHERS
AutoCAD SHX Text
SET A/C PAD ABOVE FLOOD ELEVATION W/ 1'-0" FREEBOARD PER FBCR R322.2.1.
AutoCAD SHX Text
SET W/H ABOVE FLOOD ELEVATION W/ 1'-0" FREEBOARD PER FBCR R322.2.1.
AutoCAD SHX Text
ELEV @ -0'-4"
AutoCAD SHX Text
2" SLOPE
AutoCAD SHX Text
STANDARD SGD RECESS 1-1/2". IMPACT GLASS SGD RECESS 2-1/2".
AutoCAD SHX Text
PROVIDE TERMITE TREATMENT WITH "BORA CARE"
AutoCAD SHX Text
6" X 12" RECESS
AutoCAD SHX Text
SEE DETAIL
AutoCAD SHX Text
DW.
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
AutoCAD SHX Text
W/H
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
HB
AutoCAD SHX Text
A/H
AutoCAD SHX Text
A/H
AutoCAD SHX Text
BOND BEAM & 1#5 ROD
AutoCAD SHX Text
60" HIGH WALL W/ 8"
AutoCAD SHX Text
STUB OUT FOR OPTIONAL OUTDOOR KITCHEN & SINK
AutoCAD SHX Text
MF
AutoCAD SHX Text
BRASS FLOOR OUTLET W/ SWITCH
Page 5: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

D R HORTON

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

A-3M

FLOOR

3/16"=1'-0"

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

D R HORTON

AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
%%U%%O1st FLOOR PLAN:%%O
AutoCAD SHX Text
TB
AutoCAD SHX Text
TOWEL BAR
AutoCAD SHX Text
TP
AutoCAD SHX Text
TOILET PAPER
AutoCAD SHX Text
TOWEL BAR
AutoCAD SHX Text
TOILET PAPER ROLL
AutoCAD SHX Text
BATHROOM NOTES
AutoCAD SHX Text
ALL BLOCKING TO BE PT IN SHOWERS
AutoCAD SHX Text
ALL TUB DECKS @ 21" A.F.F.
AutoCAD SHX Text
MARK
AutoCAD SHX Text
1
AutoCAD SHX Text
INTERIOR DOOR SCHEDULE
AutoCAD SHX Text
DOOR WIDTH
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
2'-8"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
2'-4"
AutoCAD SHX Text
2'-0"
AutoCAD SHX Text
1'-8"
AutoCAD SHX Text
1'-6"
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
6
AutoCAD SHX Text
7
AutoCAD SHX Text
NOTES
AutoCAD SHX Text
PK. = POCKET DOOR
AutoCAD SHX Text
B.F. = BI-FOLD DOOR
AutoCAD SHX Text
B.P. = BI-PASS DOOR
AutoCAD SHX Text
LV. = LOUVERED DOOR
AutoCAD SHX Text
MARK
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CODE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
D
AutoCAD SHX Text
C
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
CABINET BACKING
AutoCAD SHX Text
KITCHEN UPPER TOP @ 84" BASE TOP @35"
AutoCAD SHX Text
MASTER BATH UPPER BASE- TOP @35"
AutoCAD SHX Text
GUEST BATH UPPER BASE- TOP @31"
AutoCAD SHX Text
LAUNDRY RM. UPPER TOP @84" BASE
AutoCAD SHX Text
DOOR HEADERS
AutoCAD SHX Text
6'-8" BIFOLD
AutoCAD SHX Text
6'-8" SWING
AutoCAD SHX Text
8'-0" SWING
AutoCAD SHX Text
HEADER HEIGHT
AutoCAD SHX Text
82" A.F.F.
AutoCAD SHX Text
HEADER HEIGHT
AutoCAD SHX Text
HEADER HEIGHT
AutoCAD SHX Text
82 1/2" A.F.F.
AutoCAD SHX Text
98 1/2" A.F.F.
AutoCAD SHX Text
PLAN NOTES
AutoCAD SHX Text
INSTALL 1 3/8" THICK SOLID WOOD DOOR BETWEEN LIVING AND GARAGE PER FLORIDA BUILDING CODE R302.5.1,
AutoCAD SHX Text
1)
AutoCAD SHX Text
PROVIDE SAFETY GLAZING WITHIN 24" FROM EXIT PER FLORIDA BUILDING CODE R 308.4.2.
AutoCAD SHX Text
5)
AutoCAD SHX Text
3)
AutoCAD SHX Text
4)
AutoCAD SHX Text
NON BEARING INTERIOR FRAME WALLS SHALL BE FRAMED W/ WOOD OR METAL STUDS. SPACING SHALL NOT EXCEED 24" O.C. (NON BEARING WALLS ONLY)
AutoCAD SHX Text
VERIFY ALL ROUGH OPENING DIMENSIONS FOR ALL WINDOWS AND DOORS
AutoCAD SHX Text
ALL WINDOWS INSTALL 72" ABOVE GRADE MUST COMPLY WITH R 312.2.1 MIN 24" SILL HEIGHT OR PROVIDED WITH AN APPROVED WINDOW FALL PREVENTION DEVICE
AutoCAD SHX Text
9)
AutoCAD SHX Text
KITCHEN KNEE WALL TO BE FRAMED W/ TOP @ 41 1/2" A.F.F. W/ RAISED BAR TOP
AutoCAD SHX Text
THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE & ATTIC BY NOT LESS THEN 1/2" GYPSUM BOARD APPLIED TO THE GARAGE SIDE. GARAGES BENEATH HABITABLE ROOMS SHALL BE SEPARATED WITH NOT LESS THAN 5/8" TYPE "X" GYPSUM BOARD OR EQUIVALENT. WHERE THE SEPARATION IS A FLOOR - CEILING ASSEMBLY THE STRUCTURE SUPPORTING THE SEPARATION SHALL ALSO BE PROTECTED BY NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIVALENT
AutoCAD SHX Text
PROVIDE SAFETY GLAZING AT BATH / SHOWER . PER FLORIDA BUILDING CODE R 308.4.5.
AutoCAD SHX Text
PROVIDE DEAD WOOD IN ATTIC FOR OVERHEAD GARAGE DOOR HARDWARE
AutoCAD SHX Text
INSTALL SMOOTH WALLS IN KITCHEN AND ALL BATHROOM AREAS
AutoCAD SHX Text
7)
AutoCAD SHX Text
8)
AutoCAD SHX Text
2)
AutoCAD SHX Text
6)
AutoCAD SHX Text
WHERE DRYWALL CEILING IS APPLIED TO TRUSSES AT 24" O.C. USE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5
AutoCAD SHX Text
10)
AutoCAD SHX Text
11)
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text
STUB OUT FOR GAS @ OUTDOOR KITCHEN, RANGE, WATER HEATER, AND DRYER. VERIFY WITH CONTRACTOR AND SUBDIV. SPECS. A SEPARATE PERMIT IS REQUIRED FOR GAS PIPING.
AutoCAD SHX Text
12)
AutoCAD SHX Text
ALL CLOSET SHELVES TO BE 12". ALL PANTRY & LINEN TO BE (4)-16" SHELVES 18" O.F.F. WITH 15" INCREMENT.
AutoCAD SHX Text
13)
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
54
AutoCAD SHX Text
63
AutoCAD SHX Text
38
AutoCAD SHX Text
63
AutoCAD SHX Text
144
AutoCAD SHX Text
96
AutoCAD SHX Text
54
AutoCAD SHX Text
51
AutoCAD SHX Text
38
AutoCAD SHX Text
78
AutoCAD SHX Text
HB
AutoCAD SHX Text
%%U%%OFOYER
AutoCAD SHX Text
%%U%%OBEDROOM #1
AutoCAD SHX Text
%%U%%OGREAT ROOM
AutoCAD SHX Text
%%U%%OKITCHEN
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OENTRY
AutoCAD SHX Text
%%U%%OLANAI
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%u%%oBEDROOM #2
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%u%%oBEDROOM #3
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%u%%oBATH
AutoCAD SHX Text
TILE
AutoCAD SHX Text
1/4 DURK
AutoCAD SHX Text
3/4 PYW.
AutoCAD SHX Text
MUD SET BY PLUMBER
AutoCAD SHX Text
SHWR.
AutoCAD SHX Text
GLS.
AutoCAD SHX Text
TUB WALL DETAIL
AutoCAD SHX Text
7
AutoCAD SHX Text
5'-0" TUB
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
DW.
AutoCAD SHX Text
SINK & DISP
AutoCAD SHX Text
O.H CABINET
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
REF. SPACE
AutoCAD SHX Text
O.H CABINET
AutoCAD SHX Text
PANTRY
AutoCAD SHX Text
4-16" SHLV
AutoCAD SHX Text
5
AutoCAD SHX Text
12" VINYL SHELF
AutoCAD SHX Text
12" VINYL SHELF
AutoCAD SHX Text
EGRESS
AutoCAD SHX Text
EGRESS
AutoCAD SHX Text
EGRESS
AutoCAD SHX Text
2017 ACCESSIBLE
AutoCAD SHX Text
ESCAPE
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
PK.
AutoCAD SHX Text
F
AutoCAD SHX Text
A
AutoCAD SHX Text
I
AutoCAD SHX Text
D
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
SAFTEY GLAZED
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
G
AutoCAD SHX Text
E
AutoCAD SHX Text
%%u%%o#2
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
COFFERED
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
TEMPERED
AutoCAD SHX Text
10'-4"
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
13'-11"
AutoCAD SHX Text
SEE NOTE 1
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
108
AutoCAD SHX Text
63
AutoCAD SHX Text
I
AutoCAD SHX Text
SH
AutoCAD SHX Text
35
AutoCAD SHX Text
25
AutoCAD SHX Text
SH
AutoCAD SHX Text
3-4080
AutoCAD SHX Text
SL. GL. DR.
AutoCAD SHX Text
12" X 96"
AutoCAD SHX Text
SIDE LITE
AutoCAD SHX Text
2-35
AutoCAD SHX Text
SH
AutoCAD SHX Text
34
AutoCAD SHX Text
SH
AutoCAD SHX Text
2'-0" X 2'-0"
AutoCAD SHX Text
48" X 12"
AutoCAD SHX Text
F.G.
AutoCAD SHX Text
26
AutoCAD SHX Text
SH
AutoCAD SHX Text
2
AutoCAD SHX Text
13
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
4
AutoCAD SHX Text
24
AutoCAD SHX Text
24
AutoCAD SHX Text
12
AutoCAD SHX Text
96
AutoCAD SHX Text
48
AutoCAD SHX Text
12
AutoCAD SHX Text
FIXED GLASS
AutoCAD SHX Text
SL. GL. DOOR
AutoCAD SHX Text
FIXED GLASS
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
MASTER SUITE DETAIL
AutoCAD SHX Text
FOYER CEILING
AutoCAD SHX Text
FOYER CEILING
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
FOYER DETAIL
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
HALL/FOYER DETAIL
AutoCAD SHX Text
FOYER CEILING
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
DEN/FOYER DETAIL
AutoCAD SHX Text
FOYER CEILING
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
2
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
3
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
OPT IMPACT GLASS MAY BE INSTALLED IN LIEU OF SHUTTERS VERIFY W/ CONTRACT
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
16'-0" X 8'-0" O.H. GARAGE DR
AutoCAD SHX Text
SAFTEY GLAZED
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
AutoCAD SHX Text
%%U%%OBATH #1
AutoCAD SHX Text
%%u%%oW.I.C.
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
5'-0" TUB
AutoCAD SHX Text
4-SHLVS
AutoCAD SHX Text
W/H
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
22" X 36"
AutoCAD SHX Text
ATTIC ACCESS
AutoCAD SHX Text
BETTER INSULATION
AutoCAD SHX Text
MINIMUM R-13 OR
AutoCAD SHX Text
%%U%%OUTILITY
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
12" VINYL SHELF
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
A/C UNIT ON
AutoCAD SHX Text
36" X 36" PAD
AutoCAD SHX Text
SEE NOTE 10
AutoCAD SHX Text
VERIFY LOCATION WITH SITE PLAN, AC NOT TO ENCROACH EASEMENT.
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
4
AutoCAD SHX Text
SAFTEY GLAZED
AutoCAD SHX Text
6" WALL
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
SEE NOTE 9
AutoCAD SHX Text
%%U%%OTANDEM 3 CAR GARAGE
AutoCAD SHX Text
NOTE: THE GARAGE SHALL THE GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND ITS ATTIC AREA BY NOT LESS THEN " 12" GYPSUM BOARD APPLIED TO THE GARAGE SIDE
AutoCAD SHX Text
6" WALL
AutoCAD SHX Text
SQUARE FOOTAGE
AutoCAD SHX Text
LIVING AREA
AutoCAD SHX Text
GARAGE AREA
AutoCAD SHX Text
LANAI AREA
AutoCAD SHX Text
ENTRY AREA
AutoCAD SHX Text
TOTAL AREA
AutoCAD SHX Text
2221
AutoCAD SHX Text
886
AutoCAD SHX Text
196
AutoCAD SHX Text
35
AutoCAD SHX Text
3372
AutoCAD SHX Text
------------------------------
AutoCAD SHX Text
-----------------------------
AutoCAD SHX Text
-------------------------------
AutoCAD SHX Text
------------------------------
AutoCAD SHX Text
-------------------------------
AutoCAD SHX Text
ALL MECHANICAL AND ELECTRICAL EQUIPMENT TO BE INSTALLED AT OR ABOVE FLOOD PLUS 1'-0" FREEBOARD.
AutoCAD SHX Text
14)
AutoCAD SHX Text
4
AutoCAD SHX Text
8080 O.H. GARAGE DR.
AutoCAD SHX Text
HB
AutoCAD SHX Text
5
AutoCAD SHX Text
B.F.
AutoCAD SHX Text
5
AutoCAD SHX Text
B.F.
AutoCAD SHX Text
3
AutoCAD SHX Text
B.F.
AutoCAD SHX Text
3
AutoCAD SHX Text
B.F.
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
HEIGHT
AutoCAD SHX Text
MARK
AutoCAD SHX Text
SIZE
AutoCAD SHX Text
CODE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
QTY
AutoCAD SHX Text
1
AutoCAD SHX Text
2
AutoCAD SHX Text
COMMENTS
AutoCAD SHX Text
SEE NOTE 1
AutoCAD SHX Text
OVERHEAD
AutoCAD SHX Text
GARAGE DOOR
AutoCAD SHX Text
192
AutoCAD SHX Text
96
AutoCAD SHX Text
DISTINCTION
AutoCAD SHX Text
3080
AutoCAD SHX Text
36
AutoCAD SHX Text
96
AutoCAD SHX Text
ENTRY DR.
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
OVERHEAD
AutoCAD SHX Text
GARAGE DOOR
AutoCAD SHX Text
96
AutoCAD SHX Text
96
AutoCAD SHX Text
1
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OPWDR BATH
AutoCAD SHX Text
MIRROR
AutoCAD SHX Text
A/H
AutoCAD SHX Text
2
AutoCAD SHX Text
2
AutoCAD SHX Text
A/H
AutoCAD SHX Text
2
AutoCAD SHX Text
A
AutoCAD SHX Text
12" VINYL SHELF
AutoCAD SHX Text
FOYER CEILING
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
DEN/FOYER DETAIL
AutoCAD SHX Text
2-3080 12 LITE
AutoCAD SHX Text
MF
AutoCAD SHX Text
%%U%%ODEN
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
6
AutoCAD SHX Text
3
AutoCAD SHX Text
60" HIGH WALL W/ 8"
AutoCAD SHX Text
BOND BEAM & 1#5 ROD
AutoCAD SHX Text
STUB OUT FOR OPTIONAL OUTDOOR KITCHEN & SINK
AutoCAD SHX Text
1
AutoCAD SHX Text
1
AutoCAD SHX Text
2-3080 GLASS DR.
Page 6: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

A-4M

3/16"=1'-0"

ROOF & CEILING

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
%%U%%OBATH #1
AutoCAD SHX Text
%%u%%o#2
AutoCAD SHX Text
%%U%%OKITCHEN
AutoCAD SHX Text
%%u%%oBEDROOM #3
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OBEDROOM #1
AutoCAD SHX Text
%%U%%OGREAT ROOM
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OENTRY
AutoCAD SHX Text
%%U%%OLANAI
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%u%%oBEDROOM #2
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OUTILITY
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%ODEN
AutoCAD SHX Text
%%u%%oBATH
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
%%U%%OCEILING PLAN: "M"%%O
AutoCAD SHX Text
%%U%%OFOYER
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
= BEARING @ 9'-4" A.F.F.
AutoCAD SHX Text
BEARING HEIGHTS
AutoCAD SHX Text
= BEARING @ 13'-11"
AutoCAD SHX Text
COFFERED
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
10'-4"
AutoCAD SHX Text
13'-11"
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
A
AutoCAD SHX Text
A-4
AutoCAD SHX Text
A
AutoCAD SHX Text
A-4
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
ELEVATION @ WALL
AutoCAD SHX Text
ELEVATION @ +12"
AutoCAD SHX Text
A
AutoCAD SHX Text
A-4
AutoCAD SHX Text
COFFER DETAIL "A"
AutoCAD SHX Text
SCALE: 1/2"= 1'-0"
AutoCAD SHX Text
%%u%%oW.I.C.
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
HIP
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
10'-4" COFFERED CEILING
AutoCAD SHX Text
A
AutoCAD SHX Text
A-4
AutoCAD SHX Text
A
AutoCAD SHX Text
A-4
AutoCAD SHX Text
AREAS (SQ. FT.)
AutoCAD SHX Text
MODEL 2221 M: ATTIC VENTILATION FBCR R806
AutoCAD SHX Text
ATTIC VENTILATION REQUIRED
AutoCAD SHX Text
8.15%%%
AutoCAD SHX Text
3443.4 SQ. FT.
AutoCAD SHX Text
SOFFIT ONLY (1/150)
AutoCAD SHX Text
ATTIC VENTILATION REQUIRED
AutoCAD SHX Text
WITH ROOF VENTS (1/300)
AutoCAD SHX Text
ROOF VENT MODEL
AutoCAD SHX Text
"SOFFIT ONLY" QUALIFIES
AutoCAD SHX Text
1st STORY
AutoCAD SHX Text
COORDINATE VENTING REQUIREMENTS WITH ENERGY CALCULATIONS
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
QUAD 4
AutoCAD SHX Text
MARK
AutoCAD SHX Text
QUANTITY OF
AutoCAD SHX Text
REQ'D AIR FLOW
AutoCAD SHX Text
7.55%%%
AutoCAD SHX Text
MIN AIR FLOW
AutoCAD SHX Text
(NO ROOF VENTS)
AutoCAD SHX Text
-.-%
AutoCAD SHX Text
-
AutoCAD SHX Text
LOMANCO 770-D
AutoCAD SHX Text
0.97 SQ. FT. FREE AIR
AutoCAD SHX Text
ROOF VENTS ARE NOT REQUIRED
AutoCAD SHX Text
304.3 SQ. FT.
AutoCAD SHX Text
SOFFIT
AutoCAD SHX Text
OF SOFFIT
AutoCAD SHX Text
SOFFIT HAS
AutoCAD SHX Text
OF SOFFIT
AutoCAD SHX Text
(R.V.)
AutoCAD SHX Text
ACM QUAD 4, FULL VENT,
AutoCAD SHX Text
NARROW PATTERN,
AutoCAD SHX Text
8.15%%% FREE AIR FLOW
AutoCAD SHX Text
ROOF VENTS
AutoCAD SHX Text
SOFFIT MODEL
AutoCAD SHX Text
ATTIC AREA/150
AutoCAD SHX Text
22.96 SQ. FT.
AutoCAD SHX Text
ATTIC AREA/300
AutoCAD SHX Text
-.-- SQ. FT.
AutoCAD SHX Text
%%U%%OTANDEM 3 CAR GARAGE
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
CEILING
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
HIP
AutoCAD SHX Text
VALLEY
AutoCAD SHX Text
RIDGE
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
9'-4" FLAT CEILING
AutoCAD SHX Text
%%U%%OPWDR BATH
AutoCAD SHX Text
DW.
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
AutoCAD SHX Text
W/H
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
HB
AutoCAD SHX Text
A/H
AutoCAD SHX Text
A/H
AutoCAD SHX Text
MF
Page 7: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

A-5 M

ELECTRICAL

3/16"=1'-0"

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
H
AutoCAD SHX Text
H
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
GFI
AutoCAD SHX Text
WP
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
3
AutoCAD SHX Text
Electrical Notes:
AutoCAD SHX Text
All outlets in wet areas and all exterior outlets to be GFI's
AutoCAD SHX Text
Install Arc-Fault circuit-Interrupters & Tamper-Resistant Receptacles
AutoCAD SHX Text
shall be installed in dwelling unit. per NEC 210.12 & 406.11
AutoCAD SHX Text
Install Phone & T.V per contract .
AutoCAD SHX Text
INSTALL ALL ELECTRICAL PER NEC 2014
AutoCAD SHX Text
SURFACE MOUNTED CEILING LIGHT
AutoCAD SHX Text
TELEVISION RECEPTION OUTLET
AutoCAD SHX Text
AC/DC SMOKE DETECTOR
AutoCAD SHX Text
TO BE INTERCONNECTED
AutoCAD SHX Text
WALL MTD. BRACKET LIGHT
AutoCAD SHX Text
3 WAY SWITCH
AutoCAD SHX Text
DIMMER SWITCH
AutoCAD SHX Text
GFI SWITCH
AutoCAD SHX Text
TELEPHONE OUTLET
AutoCAD SHX Text
SINGLE POLE SWITCH
AutoCAD SHX Text
A/C DISCONNECT
AutoCAD SHX Text
DUPLEX FLOOD LIGHT
AutoCAD SHX Text
TRACK MTD. LIGHTS
AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
PUSH BUTTON
AutoCAD SHX Text
FLUSH MOUNTED LIGHT
AutoCAD SHX Text
1/2 SWITCHED DUPLEX OUTLET
AutoCAD SHX Text
DUPLEX RECEPTACLE OUTLET
AutoCAD SHX Text
4-PLEX RECEPTACLE OUTLET
AutoCAD SHX Text
220 V RECEPTACLE OUTLET
AutoCAD SHX Text
SINGLE RECEPTACLE OUTLET
AutoCAD SHX Text
DUPLEX RECETACLE @ ELEV. A.F.F.
AutoCAD SHX Text
ELECTRICAL PANEL
AutoCAD SHX Text
ELECTRICAL METER
AutoCAD SHX Text
120 V JUNCTION BOX
AutoCAD SHX Text
T
AutoCAD SHX Text
TIMER SWITCH
AutoCAD SHX Text
J
AutoCAD SHX Text
GFI
AutoCAD SHX Text
D
AutoCAD SHX Text
3
AutoCAD SHX Text
SD
AutoCAD SHX Text
TV
AutoCAD SHX Text
ELECTRICAL LEGEND
AutoCAD SHX Text
2' UNDER COUNTER LIGHT
AutoCAD SHX Text
4' FLUORESCENT LIGHT
AutoCAD SHX Text
K
AutoCAD SHX Text
P
AutoCAD SHX Text
KEYPAD
AutoCAD SHX Text
ANY RESIDENT HAVING A FOSSIL-BURNING
AutoCAD SHX Text
HEATER OR APPLIANCE, A FIREPLACE, OR
AutoCAD SHX Text
AN ATTACHED GARAGE SHALL HAVE AN
AutoCAD SHX Text
OPERATIONAL CARBON MONOXIDE ALARM
AutoCAD SHX Text
INSTALLED WITHIN 10 FEET OF EACH
AutoCAD SHX Text
ROOM USED FOR SLEEPING PERPOSES.
AutoCAD SHX Text
PER RULE 9B-3.04.72
AutoCAD SHX Text
DOOR BELL
AutoCAD SHX Text
DB
AutoCAD SHX Text
ELECTRICAL PLAN 2221
AutoCAD SHX Text
POWER CO.
AutoCAD SHX Text
200 AMP ELECTRICAL RISER DIAGRAM
AutoCAD SHX Text
#6 CU MIN. TO (2) GROUND RODS,
AutoCAD SHX Text
AT LEAST 6FT APART.
AutoCAD SHX Text
(2) 4/0 AL & (1) 1/0 AL
AutoCAD SHX Text
OR CU EQUIVALENT.
AutoCAD SHX Text
M
AutoCAD SHX Text
200 AMP.
AutoCAD SHX Text
PANEL
AutoCAD SHX Text
200 Amp Service
AutoCAD SHX Text
A
AutoCAD SHX Text
TAG
AutoCAD SHX Text
QUANTITY
AutoCAD SHX Text
PRODUCT
AutoCAD SHX Text
B
AutoCAD SHX Text
C
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
F
AutoCAD SHX Text
G
AutoCAD SHX Text
H
AutoCAD SHX Text
J
AutoCAD SHX Text
K
AutoCAD SHX Text
N
AutoCAD SHX Text
O
AutoCAD SHX Text
P
AutoCAD SHX Text
(25)
AutoCAD SHX Text
(4)
AutoCAD SHX Text
(1)
AutoCAD SHX Text
(X)
AutoCAD SHX Text
(3)
AutoCAD SHX Text
(2)
AutoCAD SHX Text
NOT USED
AutoCAD SHX Text
(3)
AutoCAD SHX Text
(X)
AutoCAD SHX Text
(X)
AutoCAD SHX Text
(X)
AutoCAD SHX Text
(1)
AutoCAD SHX Text
(3)
AutoCAD SHX Text
(X)
AutoCAD SHX Text
36" 4 LT
AutoCAD SHX Text
24" 3 LT
AutoCAD SHX Text
10" Mushrooms
AutoCAD SHX Text
Pendant/Nook
AutoCAD SHX Text
Vapors
AutoCAD SHX Text
Flush Mounted Lt
AutoCAD SHX Text
Coach Lights
AutoCAD SHX Text
Coach Lights
AutoCAD SHX Text
J BOX
AutoCAD SHX Text
5lt Chandelier
AutoCAD SHX Text
3 LT
AutoCAD SHX Text
Pendant Light
AutoCAD SHX Text
L
AutoCAD SHX Text
M
AutoCAD SHX Text
(4)
AutoCAD SHX Text
(3)
AutoCAD SHX Text
4' Fluorescent
AutoCAD SHX Text
2' Fluorescent
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
VP
AutoCAD SHX Text
B
AutoCAD SHX Text
EXH.
AutoCAD SHX Text
FAN
AutoCAD SHX Text
EXH.
AutoCAD SHX Text
FAN
AutoCAD SHX Text
VP
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
3
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
TV
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
O
AutoCAD SHX Text
GFI
AutoCAD SHX Text
EXH.
AutoCAD SHX Text
FAN
AutoCAD SHX Text
VP
AutoCAD SHX Text
B
AutoCAD SHX Text
E
AutoCAD SHX Text
A
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SCD
AutoCAD SHX Text
SCD
AutoCAD SHX Text
SD
AutoCAD SHX Text
SD
AutoCAD SHX Text
O
AutoCAD SHX Text
TV
AutoCAD SHX Text
PENDANT LIGHTS
AutoCAD SHX Text
%%u%%oFLOOR ELECTRICAL PLAN: %%O
AutoCAD SHX Text
"J" BOX
AutoCAD SHX Text
F
AutoCAD SHX Text
D.B.
AutoCAD SHX Text
GFI
AutoCAD SHX Text
O
AutoCAD SHX Text
WP
AutoCAD SHX Text
GFI
AutoCAD SHX Text
GFI
AutoCAD SHX Text
SCD
AutoCAD SHX Text
SCD
AutoCAD SHX Text
SD (SMOKE DETECTOR)
AutoCAD SHX Text
SCD (CARBON MONOXIDE/SMOKE DETECTOR
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
GARAGE DR OPENER
AutoCAD SHX Text
42 A.F.F.
AutoCAD SHX Text
STRUCTURED
AutoCAD SHX Text
WIRE BOX
AutoCAD SHX Text
SD
AutoCAD SHX Text
200 AMP. ELEC
AutoCAD SHX Text
PANEL BOX
AutoCAD SHX Text
VERIFY LOC.
AutoCAD SHX Text
METER
AutoCAD SHX Text
VERIFY LOC.
AutoCAD SHX Text
W/ 110 OUTLET
AutoCAD SHX Text
F
AutoCAD SHX Text
F
AutoCAD SHX Text
GFI
AutoCAD SHX Text
WP
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
O
AutoCAD SHX Text
GFI
AutoCAD SHX Text
WP
AutoCAD SHX Text
GFI
AutoCAD SHX Text
A
AutoCAD SHX Text
W/ 110 OUTLET
AutoCAD SHX Text
GFI
AutoCAD SHX Text
A
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
3
AutoCAD SHX Text
L
AutoCAD SHX Text
L
AutoCAD SHX Text
KEYLESS
AutoCAD SHX Text
A/C DISC SWITCH
AutoCAD SHX Text
42" A.F.F
AutoCAD SHX Text
All electric, electrical equipment and appliances to be set at or above base flood elevations plus 1'-0" freeboard.
AutoCAD SHX Text
L
AutoCAD SHX Text
GARAGE DR OPENER
AutoCAD SHX Text
H
AutoCAD SHX Text
E
AutoCAD SHX Text
EXH.
AutoCAD SHX Text
FAN
AutoCAD SHX Text
GFI
AutoCAD SHX Text
A/H DISC SWITCH
AutoCAD SHX Text
DW.
AutoCAD SHX Text
RANGE
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
AutoCAD SHX Text
W/H
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
L.T.
AutoCAD SHX Text
OPT.
AutoCAD SHX Text
D
AutoCAD SHX Text
W
AutoCAD SHX Text
HB
AutoCAD SHX Text
A/H
AutoCAD SHX Text
A/H
AutoCAD SHX Text
MF
AutoCAD SHX Text
BRASS FLOOR OUTLET W/ SWITCH
AutoCAD SHX Text
GFI
AutoCAD SHX Text
WP
AutoCAD SHX Text
RECESSED CAN LIGHTS EVENLY SPACED
AutoCAD SHX Text
WP GFI BELOW COUNTER TOP FOR FRIDGE
AutoCAD SHX Text
WP GFI ABOVE COUNTER TOP
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
OPTIONAL
AutoCAD SHX Text
FAN (TYP.)
AutoCAD SHX Text
PRE-WIRE FOR
AutoCAD SHX Text
TV
Page 8: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

²

²

²

A-6M

SECTION

3/16"=1'-0"

10-02-20DATE:

PLAN:

SHEET#

SCALE:

CHECKED BY:

REVISED:

DRAWN BY:

JSL

JWC

Phon

e (2

39) 5

40-1

822

Fax

(239

) 540

-775

9

& D

esig

nG

ulf

Coa

st D

raft

ing

SUBD

IV: T

OSCA

NA II

I & IV

60s

RESI

DENC

E FO

R:

G.C.

D.# :

1196

0

LOT:

340

MOD

EL:

BLOC

K :

ADDR

ESS:

174 V

ERAZ

A CO

URT

SPEC

UNIT

222

1

D.R.

H.# :

5795

9000

5

AutoCAD SHX Text
RESIDENTIAL SPECIFICATIONS
AutoCAD SHX Text
GENERAL NOTES
AutoCAD SHX Text
1. THE CONTRACTOR SHALL VERIFY ALL CONDITIONS AND DIMENSIONS AT
AutoCAD SHX Text
THE JOB SITE PRIOR TO COMMENCING WORK. THE CONTRACTOR SHALL
AutoCAD SHX Text
REPORT ALL DISCREPANCIES BETWEEN THE DRAWINGS AND EXISTING
AutoCAD SHX Text
2. THE CONTRACTOR SHALL SUPPLY, LOCATE AND BUILD INTO THE WORK
AutoCAD SHX Text
HANGERS, SLAB DEPRESSIONS AND PITCHES AS MAY BE REQUIRED TO
AutoCAD SHX Text
3. ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED
AutoCAD SHX Text
TO BE TYPICAL AND SHALL BE CONSTRUCTED TO APPLY TO ANY SIMILAR
AutoCAD SHX Text
FOUNDATIONS ARE DESIGNED FOR A SOIL BEARING CAPACITY OF 2,000
AutoCAD SHX Text
PSF. THE CONTRACTOR SHALL REPORT ANY DIFFERING CONDITIONS TO
AutoCAD SHX Text
SITUATION ELSEWHERE IN THE WORK EXCEPT WHERE A DIFFERENT
AutoCAD SHX Text
4. SUBSURFACE SOIL CONDITION INFORMATION IS NOT AVAILABLE
AutoCAD SHX Text
5. STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH JOB
AutoCAD SHX Text
SPECIFICATION AND HOUSE PLANS, MECHANICAL, ELECTRICAL,
AutoCAD SHX Text
PLUMBING, AND SITE DRAWINGS, CONSULT THESE DRAWINGS FOR
AutoCAD SHX Text
STRUCTURAL DRAWINGS.
AutoCAD SHX Text
DETAIL IS SHOWN.
AutoCAD SHX Text
CONDITIONS TO THE DESIGNER PRIOR TO COMMENCING WORK.
AutoCAD SHX Text
ALL INSERTS, ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES,
AutoCAD SHX Text
ATTACH AND ACCOMMODATE OTHER WORK.
AutoCAD SHX Text
THE DESIGNER PRIOR TO COMMENCING WORK.
AutoCAD SHX Text
SLEEVES, DEPRESSIONS AND OTHER DETAILS NOT SHOWN ON
AutoCAD SHX Text
THE BUILDING AND ITS COMPONENTS DURING ERECTION. THIS INCLUDES THE
AutoCAD SHX Text
NECESSARY SHORING, SHEETING, TEMPORARY BRACING, GUYS, OR TIE DOWNS.
AutoCAD SHX Text
6. ALL SPECIFIED FASTENERS MAY ONLY BE SUBSTITUTED IF APPROVED BY THE
AutoCAD SHX Text
ENGINEER IN WRITING, THE INSTALLATION OF THE FASTENERS
AutoCAD SHX Text
ALL WOOD EXPOSED TO WEATHER SHALL BE PROTECTED, PRESSURE TREATED,
AutoCAD SHX Text
8. THE STRUCTURE IS DESIGNED TO BE SELF SUPPORTING AND STABLE AFTER
AutoCAD SHX Text
THE BUILDING IS COMPLETE. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY
AutoCAD SHX Text
TO DETERMINE ERECTION PROCEDURES AND SEQUENCES TO ENSURE SAFETY OF
AutoCAD SHX Text
SHALL BE IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.
AutoCAD SHX Text
SIMPSON FASTENERS SPECIFIED MAY BE SUBSTITUTED WITH THE SAME QUANTITY
AutoCAD SHX Text
AND EQUIVALENT STRENGTH PRODUCT.
AutoCAD SHX Text
7. TREATED WOOD REQUIREMENTS:-
AutoCAD SHX Text
OR NATURALLY RESISTANT TO DECAY.
AutoCAD SHX Text
ALL WOOD TOUCHING MASONRY OR CONCRETE SHALL BE ISOLATED, OR
AutoCAD SHX Text
PRESSURE TREATED.
AutoCAD SHX Text
9. CEILING DRYWALL INSTALLED WITHIN THE HOUSE TO TRUSSES SPACED 24" O.C.
AutoCAD SHX Text
SHALL BE 5/8" DRYWALL OR 1/2" SAG RESISTANT PER SEC. 702.3.5
AutoCAD SHX Text
1
AutoCAD SHX Text
10. LANAI CEILINGS & COVERED ENTRY CEILINGS
AutoCAD SHX Text
1X4 STRIPPING @ 16" O.C. FASTENED WITH 2-8d NAILS TO EACH TRUSS. 5/8"
AutoCAD SHX Text
EXTERIOR GYPBOARD CEILING FASTENED WITH 8d NAILS OR 1-5/8" DRYWALL
AutoCAD SHX Text
SCREWS @ 6" oc EDGE AND FIELD.
AutoCAD SHX Text
3
AutoCAD SHX Text
4
AutoCAD SHX Text
FLOOR SHEATHING AT 2ND FLOOR
AutoCAD SHX Text
A.P.A. RATED STURDI-FLOOR, EXPOSURE 1, TONGUE & GROOVE EDGES
AutoCAD SHX Text
5
AutoCAD SHX Text
SPAN RATING 48/24 OR BETTER, GLUED AND NAILED
AutoCAD SHX Text
SHINGLES
AutoCAD SHX Text
15# felt shall be installed under asphalt shingles. All asphalt
AutoCAD SHX Text
shingles shall have self sealing strips or be interlocking and
AutoCAD SHX Text
comply with ASTM D 225 or D3462, and shall be secured to the
AutoCAD SHX Text
roof with no less than 6 fasteners per shingle strip, or a minimum
AutoCAD SHX Text
of 2 fasteners per shingle tab. And shall in no case be fastened
AutoCAD SHX Text
with less fasteners than that required by the manufacture.
AutoCAD SHX Text
Installation shall comply with the manufactures requirements for
AutoCAD SHX Text
installation in the given Florida wind zone, as determined by
AutoCAD SHX Text
ASTM D 3161.
AutoCAD SHX Text
FASTENERS
AutoCAD SHX Text
Fasteners for asphalt shingles shall comply with ASTM F 1667, and
AutoCAD SHX Text
shall be made of galvanized steel, stainless steel or aluminum with
AutoCAD SHX Text
a minimum shank size of 12 gage (0.105 inches)with a minimum 3/8 inch
AutoCAD SHX Text
diameter head and shall be of a length to penetrate the
AutoCAD SHX Text
sheathing.
AutoCAD SHX Text
The nail component of plastic cap nails shall meet or exceed the
AutoCAD SHX Text
requirements of ASTM A 641, Class I, or equal, and shall be
AutoCAD SHX Text
corrosion resistant by coating electro galvanization, mechanical
AutoCAD SHX Text
galvanization, hot dipped galvanization or shall be made of
AutoCAD SHX Text
stainless steel, non ferrous metal.
AutoCAD SHX Text
ASPHALT SHINGLE ROOF SPEC'S
AutoCAD SHX Text
CLAY AND CONCRETE TILE ROOF SPECS
AutoCAD SHX Text
THE INSTALLATION OF CLAY AND CONCRETE TILE SHALL COMPLY
AutoCAD SHX Text
WITH THE PROVISIONS OF R905.3 F.B.C.
AutoCAD SHX Text
MARKING: EACH ROOF TILE SHALL HAVE A PERMANENT
AutoCAD SHX Text
MANUFACTURER'S IDENTIFICATION MARK.
AutoCAD SHX Text
APPLICATION SPECIFICATIONS: THE TILE MANUFACTURER'S WRITTEN
AutoCAD SHX Text
APPLICATION SPECIFICATIONS SHALL BE AVAILABLE AND SHALL
AutoCAD SHX Text
INCLUDE BUT NOT BE LIMITED TO THE FOLLOWING:
AutoCAD SHX Text
1. TILE PLACEMENT AND SPACING,
AutoCAD SHX Text
2. ATTACHMENT SYSTEM NECESSARY TO
AutoCAD SHX Text
A. AMOUNT AND PLACEMENT OF MORTAR
AutoCAD SHX Text
B. AMOUNT AND PLACEMENT OF ADHESIVE,
AutoCAD SHX Text
C. TYPE, NUMBER, SIZE, AND LENGTH OF FASTENERS AND CLIPS.
AutoCAD SHX Text
3. UNDERLAYMENT
AutoCAD SHX Text
4. SLOPE REQUIREMENT.
AutoCAD SHX Text
INSTALL PEEL AND STICK UNDERLAYMENT APPROVED FOR SINGLE
AutoCAD SHX Text
LAYER APPLICATION UNDER TILE ROOF.
AutoCAD SHX Text
ROOF SHEATHING
AutoCAD SHX Text
SHEETS SHALL BE MAINTAINED. INSTALL "H" CLIPS AT UNSUPPORTED PANEL EDGES.
AutoCAD SHX Text
FLASHING
AutoCAD SHX Text
FLASHING SHALL BE ALUMINUM, ALUMINUM ZINC COATED STEEL .0179 INCHES
AutoCAD SHX Text
THICK, 26 GAGE AZ50 ALUM ZINC, OR GALVANIZED STEEL .0179 INCHES THICK, 26 GAGE
AutoCAD SHX Text
ZINC COATED G90, FLASHING SHALL BE INSTALLED IN ACCORDANCE WITH THE ZIP
AutoCAD SHX Text
SYSTEM ROOF SHEATHING MANUFACTURERS PUBLISHED REQUIREMENTS. ALL FLASHING AND
AutoCAD SHX Text
INSTALLATION SHALL CONFORM TO SECTION R905.2.8 (1 TO 5).
AutoCAD SHX Text
SHALL BE APA RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER.
AutoCAD SHX Text
DIMENSION PLACED PERPENDICULAR TO TRUSSES. A 1/8" SPACE BETWEEN ADJACENT
AutoCAD SHX Text
GENERAL ROOF ASSEMBLY
AutoCAD SHX Text
2
AutoCAD SHX Text
INSTALL PANELS WITH LONG
AutoCAD SHX Text
DRIP EDGE
AutoCAD SHX Text
DRIP EDGE SHALL BE PROVIDED AT ALL EAVES AND GABLES OF SHINGLE ROOFS,
AutoCAD SHX Text
LAPPED A MINIMUM OF 3" @ JOINTS. THE OUTSIDE EDGE SHALL EXTEND A MINIMUM OF 1/2"
AutoCAD SHX Text
BELOW SHEATHING AND THE INSIDE EDGE SHALL EXTEND BACK A MINIMUM OF 2". DRIP
AutoCAD SHX Text
EDGE SHALL BE FASTENED AT NO MORE THAN 4" CENTERS. THERE SHALL BE A
AutoCAD SHX Text
MINIMUM OF 4" WIDTH OF ROOF CEMENT INSTALLED OVER THE DRIP EDGE FLANGE.
AutoCAD SHX Text
COMPLY WITH CURRENT WIND CODE,
AutoCAD SHX Text
FINISH FLOOR
AutoCAD SHX Text
5.7 SQ. CLEAR OPENING
AutoCAD SHX Text
MINIMUM EGRESS WINDOW DETAIL
AutoCAD SHX Text
R310.2.1 MINIMUM OPENING AREA:- ALL EMERGENCY ESCAPE AND RESCUE ALL EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5.7 SQAURE FEET (0.530 m² ). ). EXCEPTION:- GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET GRADE FLOOR OPENINGS SHALL HAVE A MINIMUM NET CLEAR OPENING OF 5 SQUARE FEET (0.465 m² ). ). R310.2.1 MINIMUM OPENING HEIGHT:- THE MINIMUM NET CLEAR OPENING THE MINIMUM NET CLEAR OPENING HEIGHT SHALL BE 24 INCHES (610mm). R310.2.1 MINIMUM OPENING WIDTH:- THE MINIMUM NET CLEAR OPENING THE MINIMUM NET CLEAR OPENING WIDTH SHALL BE 20 INCHES (508mm). R310.1.1 OPERATIONAL CONSTRAINTS:- EMERGENCY ESCAPE AND RESCUE EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL BE OPERATIONAL FROM THE INSIDE OF THE ROOM WITHOUT THE USE OF KEYS OR TOOLS. R310.2.3 WINDOW WELLS:- THE MINIMUM HORIZONTAL AREA OF THE WINDOW THE MINIMUM HORIZONTAL AREA OF THE WINDOW WELL SHALL BE 9 SQUARE FEET (0.84 m² ), WITH A MINIMUM HORIZONTAL ), WITH A MINIMUM HORIZONTAL PROJECTION AND WIDTH OF 36 INCHES (914mm). THE AREA OF THE WINDOW WELL SHALL ALLOW THE EMERGENCY ESCAPE AND RESCUE OPENING TO BE FULLY OPENED.
AutoCAD SHX Text
NOTE:EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND EXTERIOR WALLS ADJACENT TO ATTIC SPACE, INCLUDING KNEEWALLS AND GABLE END WALLS, MUST HAVE RADIANT BARRIER AND HOUSE WRAP.
AutoCAD SHX Text
RADIANT BARRIER:
AutoCAD SHX Text
SCALE: N.T.S.
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
GABLE WALL
AutoCAD SHX Text
EXTERIOR STUD WALL OR TRUSS
AutoCAD SHX Text
EXTERIOR PLYWOOD W/ RADIANT BARRIER ON ATTIC SIDE
AutoCAD SHX Text
HOUSE WRAP
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
RADIANT BARRIER GLUED TO PLYWOOD
AutoCAD SHX Text
TOP CHORD
AutoCAD SHX Text
ATTIC
AutoCAD SHX Text
EXTERIOR
AutoCAD SHX Text
SLOPE TO EXTERIOR
AutoCAD SHX Text
2
AutoCAD SHX Text
TYPICAL WALL SECTION
AutoCAD SHX Text
SCALE: N.T.S
AutoCAD SHX Text
WOOD BASE
AutoCAD SHX Text
W/ INSULATION (MIN. R4.1)
AutoCAD SHX Text
1/2" DRYWALL W/ TEXTURED WALLS.
AutoCAD SHX Text
1X2 P.T. FURRING STRIPS @ 24" O.C.
AutoCAD SHX Text
GRADE
AutoCAD SHX Text
8"X8"X16" CONC. BLOCK
AutoCAD SHX Text
1X4 P.T. STRIP.
AutoCAD SHX Text
SIZE AND REINFORCING.
AutoCAD SHX Text
FOUNDATION PLAN FOR
AutoCAD SHX Text
CONCRETE FOOTING SEE
AutoCAD SHX Text
WINDOW, SEE SCHEDULE AND PLAN.
AutoCAD SHX Text
PER NOTE 9 IN
AutoCAD SHX Text
DRYWALL CEILING
AutoCAD SHX Text
TABLE 1 ON A-6
AutoCAD SHX Text
SEE ENGINEERING
AutoCAD SHX Text
PRECAST LINTEL
AutoCAD SHX Text
FLASHING AND DRIP EDGE
AutoCAD SHX Text
PER NOTES IN TABLE 2 ON A-6
AutoCAD SHX Text
EMBEDDED STRAP AT EACH
AutoCAD SHX Text
TRUSS PER ROOF FRAMING PLAN.
AutoCAD SHX Text
WOOD TRUSSES @ 24" O.C. (TYPICAL)
AutoCAD SHX Text
DESIGNED BY DELEGATED TRUSS ENGINEER.
AutoCAD SHX Text
ROOF SHEATHING PER SCHEDULE 2/S-3
AutoCAD SHX Text
TILE ROOF PER NOTE 4 ON A-6.
AutoCAD SHX Text
AND PER NOTES IN TABLE 2 ON A-6
AutoCAD SHX Text
1X4 P.T. BUCK W/ BED
AutoCAD SHX Text
OF CONTINOUS CAULK
AutoCAD SHX Text
UNDER, SEE 13/S-3
AutoCAD SHX Text
SILL SET IN MORTAR
AutoCAD SHX Text
PRECAST CONCRETE SILL
AutoCAD SHX Text
DECORATIVE CEMENT FINISH
AutoCAD SHX Text
PER ASTMC-926
AutoCAD SHX Text
8"X8" CONTINUOUS
AutoCAD SHX Text
SEE ENGINEERING
AutoCAD SHX Text
BOND BEAM
AutoCAD SHX Text
VENTED ALLUM SOFFIT
AutoCAD SHX Text
SHALL MEET R703.1.2.1
AutoCAD SHX Text
PROVIDE VENTILATION
AutoCAD SHX Text
PER R806.1
AutoCAD SHX Text
SEE TABLE 3 ON S-3
AutoCAD SHX Text
CORNER OF
AutoCAD SHX Text
MID WALL
AutoCAD SHX Text
FELT STRIP
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
CORNER BEAD
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
FELT STRIP
AutoCAD SHX Text
WIRE LATH
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
OVER FELT
AutoCAD SHX Text
OVER FELT STRIP
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
FELT STRIP
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
CORNER OF
AutoCAD SHX Text
BUILDING
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
OVER WIRE LATH
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
OVER BLOCK WALL
AutoCAD SHX Text
OVER WIRE LATH
AutoCAD SHX Text
EXPANSION JOINT
AutoCAD SHX Text
DECO. TEXTURED FINISH
AutoCAD SHX Text
OVER WIRE LATH
AutoCAD SHX Text
DECO. TEXTURED FINISH
AutoCAD SHX Text
FRAME WALL
AutoCAD SHX Text
FELT OVER
AutoCAD SHX Text
FRAME WALL
AutoCAD SHX Text
WIRE LATH
AutoCAD SHX Text
OVER FELT
AutoCAD SHX Text
MID WALL
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
OVER FELT STRIP
AutoCAD SHX Text
WIRE LATH OVER
AutoCAD SHX Text
MID WALL
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
OVER FELT STRIP
AutoCAD SHX Text
FRAME WALL
AutoCAD SHX Text
FELT PAPER
AutoCAD SHX Text
MITER OVER SCREED
AutoCAD SHX Text
WIRE THE CONTROL
AutoCAD SHX Text
JOINT TO LATH WITH
AutoCAD SHX Text
18 GA. GALVANIZED
AutoCAD SHX Text
WIRE AT 7' O.C. MAX.
AutoCAD SHX Text
AMICO M-TYPE
AutoCAD SHX Text
CONTROL JOINT
AutoCAD SHX Text
AMCJM-780 OR
AutoCAD SHX Text
APPROVED EQUAL
AutoCAD SHX Text
OVER LATH (CUT
AutoCAD SHX Text
LATH BEHIND
AutoCAD SHX Text
CONTROL JOINT 1/4'
AutoCAD SHX Text
MIN. GAP) LOCATE
AutoCAD SHX Text
OVER STUD ONLY
AutoCAD SHX Text
AND PER NOTE 1
AutoCAD SHX Text
FULLY EMBED BACK FACE
AutoCAD SHX Text
OF WEEP SCREED IN
AutoCAD SHX Text
CAULK. LET OOZE OUT AT
AutoCAD SHX Text
CORNER AND SCREED 2"
AutoCAD SHX Text
MIN. WIDTH
AutoCAD SHX Text
MITER OUT CORNER
AutoCAD SHX Text
BEAD AT
AutoCAD SHX Text
MID WALL
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
*
AutoCAD SHX Text
NOTE 1:
AutoCAD SHX Text
MAX OF 144 SQ. FT.
AutoCAD SHX Text
BETWEEN CONTROL
AutoCAD SHX Text
JOINTS. NOT GREATER
AutoCAD SHX Text
THAN 18'-0"O.C. MAX
AutoCAD SHX Text
AREA RATIO OF
AutoCAD SHX Text
CONTROL JOINTS-2-2/1 TO 1
AutoCAD SHX Text
(AT WOOD
AutoCAD SHX Text
FRAME ONLY)
AutoCAD SHX Text
*
AutoCAD SHX Text
CAULK CENTER JOINT
AutoCAD SHX Text
IN MID WALL WEEP
AutoCAD SHX Text
SCREED 2" IN EA.
AutoCAD SHX Text
DIRECTION AT CORNER
AutoCAD SHX Text
WOOD FRAME
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
%%UMASONRY WALL
AutoCAD SHX Text
%%UMASONRY WALL
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
%%UWEEP SCREED DETAIL
AutoCAD SHX Text
INSTALL AT ALL EXTERIOR WALL LOCATIONS WHERE
AutoCAD SHX Text
WOOD STUD FRAMING IS ABOVE MASONRY WALLS.
AutoCAD SHX Text
MID WALL
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
OVER FELT STRIP
AutoCAD SHX Text
MASONRY NAIL
AutoCAD SHX Text
6" WIDE FELT
AutoCAD SHX Text
METAL LATH
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
PAPER BACK
AutoCAD SHX Text
WALL SHEATHING
AutoCAD SHX Text
WITH HOUSE WRAP
AutoCAD SHX Text
OR ZIP SYSTEM
AutoCAD SHX Text
WALL SHEATHING
AutoCAD SHX Text
WOOD FRAMING EITHER FLOOR TRUSS OR GABLE END TRUSS
AutoCAD SHX Text
C
AutoCAD SHX Text
L
AutoCAD SHX Text
FELT AND
AutoCAD SHX Text
WEEP SCREED
AutoCAD SHX Text
%%UMID WALL WEEP SCREED DETAIL
AutoCAD SHX Text
OVER
AutoCAD SHX Text
WITH FELT
AutoCAD SHX Text
FRAME WALL
AutoCAD SHX Text
WIRE LATH
AutoCAD SHX Text
WOOD FRAME
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
SCALE: N.T.S.
AutoCAD SHX Text
%%UPAN FLASHING PER R703.4
AutoCAD SHX Text
R703.4 - Where flashing instructions or details are not provided by the window or door manufacturer or by the flashing manufacturer, "pan flashing" shall be installed at the sill of exterior window and door openings. Pan flashing shall be sealed or sloped in such a manner as to direct water to the surface of the exterior wall finish or to the water-resistive barrier for subsequent drainage. Openings using pan flashing shall incorporate flashing or protection at the head and sides.
AutoCAD SHX Text
"Pan Flashing" is a generic term that used to refer to "metal pan flashing". However many modern materials have been developed for the same function such as: - Flexible Peel n Stick Flashing Membrane - Fluid Applied Flashing For such products, follow the manufacturer's installation instructions.
AutoCAD SHX Text
INSTALL "PAN" FLASHING AT THE SILL
AutoCAD SHX Text
WHERE "PAN" FLASHING IS USED AT THE SILL, ALSO INCORPORATE FLASHING OR PROTECTION AT THE HEAD AND SIDES
AutoCAD SHX Text
EXTERIOR WALL
AutoCAD SHX Text
OPENING FOR WINDOW OR DOOR
AutoCAD SHX Text
THE FLASHING INSTRUCTIONS FROM THE WINDOW / DOOR MFR., OR THE FLASHING MFR., SHALL SUPERCEDE THIS DETAIL.
AutoCAD SHX Text
For in-depth flashing installation instructions, refer to the following publications: FMA/AAMA 100 FMA/AAMA 200 FMA/WDMA 250 FMA/AAMA/WDMA 300
AutoCAD SHX Text
4" CONC. SLAB ON 6 MIL. VISQUEEN VAPOR BARRIER ON MECHANICALLY COMPACTED FILL @ 95%.
AutoCAD SHX Text
2X6 MIN. SUB FASCIA
AutoCAD SHX Text
PROVIDE TERMITE TREATMENT WITH "BORA CARE".
AutoCAD SHX Text
SEE ENERGY CODE FORMS FOR INSULATION R-VALUES
AutoCAD SHX Text
DESIGN IN ACCORDANCE W/ THE 2017 RESIDENTIAL FLORIDA BUILDING CODE- 6TH EDITION
Page 9: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
#5 DOWELS WITH 7" HOOK, EMBED 8" MIN
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
%%UFOOTING DETAILS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%U'F5' FOOTING
AutoCAD SHX Text
%%U'F3' FOOTING
AutoCAD SHX Text
%%U'F6A' STEPDOWN
AutoCAD SHX Text
%%UGARAGE DOOR RECESS
AutoCAD SHX Text
2-#5 CONTINUOUS w/ 3" CLEAR COVER
AutoCAD SHX Text
4" CONCRETE SLAB
AutoCAD SHX Text
RECESS
AutoCAD SHX Text
2-#5 CONTINUOUS w/ 3" CLEAR COVER
AutoCAD SHX Text
2-#5 CONTINUOUS w/ 3" CLEAR COVER
AutoCAD SHX Text
1-#5 CONTINUOUS w/ 3" CLEAR COVER
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
#5 DOWELS WITH 7" HOOK, EMBED 8" MIN BELOW GARAGE FLOOR
AutoCAD SHX Text
%%U'F3' WITH CURB AT GARAGE
AutoCAD SHX Text
2-#5 CONTINUOUS w/ 3" CLEAR COVER
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
CURB IS OPTIONAL AND NOT INCLUDED IN FOOTING DIMENSIONS
AutoCAD SHX Text
%%U'P' PAVER RIBBON
AutoCAD SHX Text
MORTAR BED
AutoCAD SHX Text
PAVERS
AutoCAD SHX Text
8"x8" CONCRETE RIBBON AT EDGE OF PAVERS w/ 1-#5
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
F6A
AutoCAD SHX Text
F6A
AutoCAD SHX Text
F6A
AutoCAD SHX Text
F6A
AutoCAD SHX Text
SET 8F8-1B LINTEL AT GARAGE DOOR HEAD HEIGHT, ADD COURSING AS REQUIRED TO 8x8 BOND BEAM w/ 1#5 , TOP @ 9'-4", GROUT ALL SOLID
AutoCAD SHX Text
6"x12" RECESS, SEE DETAIL
AutoCAD SHX Text
0'-0" REFERENCE
AutoCAD SHX Text
4" SLAB w/ 2,500 PSI CONC. w/ 6x6#10/10 W.W.M. REINFORCING OVER 6 MIL VISQUEEN BARRIER ON MECHANICALLY COMPACTED FILL @ 95%
AutoCAD SHX Text
THE FINISH FLOOR SLAB SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP PLUS 1'-0" FREEBOARD PER FBCR R322.2.1, SEE SITE PLAN BY OTHERS
AutoCAD SHX Text
SLOPE 2"
AutoCAD SHX Text
-4"
AutoCAD SHX Text
-4"
AutoCAD SHX Text
PAVERS BY OTHERS
AutoCAD SHX Text
RECESS SGD 1-1/2" FOR CONCRETE LANAI. RECESS 2-1/2" FOR PAVER LANAI OR WHERE IMPACT WINDOWS ARE REQUIRED.
AutoCAD SHX Text
SHOWER RECESS, SEE HOUSE PLANS
AutoCAD SHX Text
8"x8" THICKENED SLAB @ SHOWER
AutoCAD SHX Text
HOLLOW DOT IS #5 VERTICAL IN WINDOW SILL (NO VERTICALS IN HEADER)
AutoCAD SHX Text
PAVERS BY OTHERS
AutoCAD SHX Text
'P'
AutoCAD SHX Text
'P'
AutoCAD SHX Text
'P'
AutoCAD SHX Text
FOR PLUMBING EMBEDS IN SLAB, SEE HOUSE PLAN SHEET A-2
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
PROVIDE TERMITE TREATMENT ABOVE SLAB WITH "BORA CARE"
AutoCAD SHX Text
#5 BAR IN GROUTED CELL, LAP 25" WITH #5 DOWEL OUT OF SLAB, WITH 7" HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
SET A/C PAD ABOVE BASE FLOOD ELEVATION w/ 1'-0" FREEBOARD PER FBCR R322.2.1
AutoCAD SHX Text
SET W/H ABOVE BASE FLOOD ELEVATION w/ 1'-0" FREEBOARD PER FBCR R322.2.1
AutoCAD SHX Text
INSTALL 1~6" THICKSOLID WOOD DOOR BETWEEN LIVING AND GARAGE PER FLORIDA BUILDING CODE R302.5.1
AutoCAD SHX Text
SAWCUT SLAB PER DETAIL 5/S-3
AutoCAD SHX Text
F3 w/ CURB
AutoCAD SHX Text
LOWEST POINT OF GARAGE SLAB SHALL BE SET ABOVE BASE FLOOD ELEVATION PER FEMA FLOOD MAP
AutoCAD SHX Text
A
AutoCAD SHX Text
B
AutoCAD SHX Text
6"x12" RECESS,
AutoCAD SHX Text
SEE DETAIL
AutoCAD SHX Text
F3 w/ CURB
AutoCAD SHX Text
C
AutoCAD SHX Text
PLAN NOTES: 1) TOP OF GROUND FLOOR SLAB DATUM ELEVATION 0'-0". 2) 'F#' DENOTES CONTINUOUS WALL FOOTING TYPE PER SCHEDULE THIS SHEET. 3) # DENOTES PAD FOOTING AT CONCENTRATED LOADS PER SCHEDULE THIS SHEET. 4) "P" DENOTES 8"x8" CONCRETE RIBBON w/ 1-#5 BAR AT EDGE OF PAVERS. 5) PROVIDE #5 VERTICAL REINFORCING AT DOT LOCATIONS SHOWN ON PLAN FROM FOOTING TO BOND BEAM. 6) ALL DIMENSIONS ARE TO OUTSIDE FACE OF MASONRY WALLS. SOME SLAB EDGES MAY EXTEND BEYOND FACE OF WALL. 7) FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/DOOR SUPPLIER. 8) PROVIDE PRESSURE TREATED BUCKS AT WINDOWS / DOORS PER DETAIL 7/S-3.
AutoCAD SHX Text
NOTE: REINFORCING IN FOOTINGS SHALL BE CONTINUOUS AT CORNERS AND INTERSECTIONS. ADD CORNER BAR 25"x25" AT EACH LONGITUDINAL BAR PER DETAIL 6/S-3.
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
1'-2"
AutoCAD SHX Text
1'-2"
AutoCAD SHX Text
PAD FOOTING SCHEDULE
AutoCAD SHX Text
D
AutoCAD SHX Text
E
AutoCAD SHX Text
4'-0"
AutoCAD SHX Text
5'-0"
AutoCAD SHX Text
4'-0"
AutoCAD SHX Text
5'-0"
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
B
AutoCAD SHX Text
A
AutoCAD SHX Text
C
AutoCAD SHX Text
USED
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
3'-0"
AutoCAD SHX Text
2'-6"
AutoCAD SHX Text
3'-6"
AutoCAD SHX Text
5-#5
AutoCAD SHX Text
6-#5
AutoCAD SHX Text
5-#5
AutoCAD SHX Text
6-#5
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
BOTTOM REINF.
AutoCAD SHX Text
4-#5
AutoCAD SHX Text
3-#5
AutoCAD SHX Text
4-#5
AutoCAD SHX Text
SHORT WAY
AutoCAD SHX Text
LONG WAY
AutoCAD SHX Text
4-#5
AutoCAD SHX Text
3-#5
AutoCAD SHX Text
4-#5
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
-
AutoCAD SHX Text
1'-8"
AutoCAD SHX Text
0'-10"
AutoCAD SHX Text
0'-8"
AutoCAD SHX Text
DEPTH
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
1'-8"
AutoCAD SHX Text
WALL FOOTING SCHEDULE
AutoCAD SHX Text
F4
AutoCAD SHX Text
F6
AutoCAD SHX Text
F5
AutoCAD SHX Text
F3
AutoCAD SHX Text
F2
AutoCAD SHX Text
F1
AutoCAD SHX Text
USED
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
1'-4"
AutoCAD SHX Text
1'-4"
AutoCAD SHX Text
1'-4"
AutoCAD SHX Text
1'-0"
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
1'-8"
AutoCAD SHX Text
1'-4"
AutoCAD SHX Text
WIDTH
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
LENGTH
AutoCAD SHX Text
SHAPE
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
BOTTOM
AutoCAD SHX Text
REINFORCING
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
2-#5
AutoCAD SHX Text
%%uFOUNDATION PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
0'-8"
AutoCAD SHX Text
F6A
AutoCAD SHX Text
0'-8"
AutoCAD SHX Text
CONT.
AutoCAD SHX Text
1-#5
AutoCAD SHX Text
A
AutoCAD SHX Text
F1
AutoCAD SHX Text
60" HIGH PRIVACY WALL w/ 8x8 BOND BEAM AT TOP WITH 1-#5
AutoCAD SHX Text
STUB OUT FOR OPTIONAL OUTDOOR KITCHEN AND SINK
AutoCAD SHX Text
A
AutoCAD SHX Text
A
AutoCAD SHX Text
F3
AutoCAD SHX Text
F3
AutoCAD SHX Text
S-1
AutoCAD SHX Text
1
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
DWB/GH
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/6/20
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
DR 11960
AutoCAD SHX Text
SHEET OF 4
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
MODEL 2221 M
AutoCAD SHX Text
174 VERAZA COURT VENICE, FLORIDA LOT: 340 BLOCK: SUBDIVISION: TOSCANA III & IV 60s
AutoCAD SHX Text
FOR BUILDERS FIRST SOURCE TRUSS, 160 MPH, EXPOSURE C, M ELEVATION, 3 CAR, JOB # MASTER, DATE DRAWN: 08/11/20, DATE PRINTED: 08/11/20, REVISED: NONE
AutoCAD SHX Text
3 CAR GARAGE
Ralph
Seal
Ralph
Signature Statement Square
Page 10: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

” ”” ”

” ”

AutoCAD SHX Text
%%UBEVELED BLOCKING
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
ROOF SHEATHING
AutoCAD SHX Text
ROOF TRUSS
AutoCAD SHX Text
2x_ BLOCKING w/ BEVEL CUT TOP. BLOCKING CAN BE EITHER SIDE OF TRUSS
AutoCAD SHX Text
16d NAILS @ 8" OC
AutoCAD SHX Text
8d RING SHANK NAILS @ 6" OC
AutoCAD SHX Text
%%U8F16-1B/1T
AutoCAD SHX Text
%%U8F16-1B/1T
AutoCAD SHX Text
%%U8F16-1B/1T
AutoCAD SHX Text
SET 8F8-1B LINTEL AT GARAGE DOOR HEAD HEIGHT, ADD COURSING AS REQUIRED TO 8x8 BOND BEAM w/ 1#5 , TOP @ 9'-4", GROUT ALL SOLID
AutoCAD SHX Text
%%U8F8-1B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-1B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
%%U8F8-1B
AutoCAD SHX Text
%%U8F8-1B
AutoCAD SHX Text
BOT @ 11'-2~8"
AutoCAD SHX Text
S-3
AutoCAD SHX Text
10
AutoCAD SHX Text
S-4
AutoCAD SHX Text
3
AutoCAD SHX Text
S-4
AutoCAD SHX Text
1
AutoCAD SHX Text
LANAI CEILING PER 2/S-3
AutoCAD SHX Text
ATTIC ACCESS
AutoCAD SHX Text
(+33.5, -36.3) WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND CONVERTED TO ALLOWABLE STRESS DESIGN PRESSURES USING 0.6W LOAD FACTOR. (Vasd=124 MPH, RISH CAT II, ENCLOSED, kd=0.85, H=15')
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+29.4, -33.3)
AutoCAD SHX Text
(+28.2, -31.5)
AutoCAD SHX Text
(+33.5, -44.8)
AutoCAD SHX Text
(+33.5, -36.3)
AutoCAD SHX Text
(+33.5, -44.8)
AutoCAD SHX Text
AIR HANDLER IN CLOSET BELOW. NO RECESS IN TRUSS
AutoCAD SHX Text
FALSE KNEEWALL
AutoCAD SHX Text
FALSE KNEEWALL
AutoCAD SHX Text
META16, TYP
AutoCAD SHX Text
1-META16 @ TRUSS A01
AutoCAD SHX Text
1-META16 @ TRUSS A01
AutoCAD SHX Text
1-META16 @ D5
AutoCAD SHX Text
1-META16 @ D5
AutoCAD SHX Text
1-META16 @ B03
AutoCAD SHX Text
ENTRY CEILING PER 2/S-3
AutoCAD SHX Text
ADD COURSING AS NEEDED TO 8x8 BOND BEAM w/ 1#5, TOP @ 13'-11"
AutoCAD SHX Text
PER FBC 2017 R302.6: Dwelling/garage fire separation - The garage shall be separated from the residence and attics by not less than 1/2 inch gypsum board or equivalent applied to the garage side. Structures supporting floor/ceiling assemblies used for separation shall have not less than 1/2 inch gypsum board or equivalent.
AutoCAD SHX Text
WHERE DRYWALL CEILING IS APPLIED TO TRUSSES AT 24" O.C., USE ~0" DRYWALL OR ~8" SAG RESISTANT PER SETION 702.3.5
AutoCAD SHX Text
EMBED 1-META16 AT ALL TRUSSES EXCEPT AS NOTED AT GIRDERS
AutoCAD SHX Text
8x8 CONTINUOUS MASONRY BOND BEAM AT TOP OF WALL WITH 1#5 BAR, PROVIDE CORNER BARS PER 8/S-3
AutoCAD SHX Text
WHERE ROOF SHEATHING CONTACTS ONLY THE EDGE OF ROOF TRUSSES, INSTALL BEVELLED BLOCKING PER DETAIL THIS SHEET (DR HORTON REQUIREMENT)
AutoCAD SHX Text
DUAL BEARING, MASONRY TO 9'-4", STUD KNEEWALL TO 13'-11"
AutoCAD SHX Text
#5 BAR IN GROUTED CELL w/ 7" HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
CORNER BARS IN BOND BEAM PER 8/S-3
AutoCAD SHX Text
1-META16 @ F1
AutoCAD SHX Text
1-META16 @ F1
AutoCAD SHX Text
1-HTT4 @ F3 w/ ~0" ALLTHREAD, DRILL & EPOXY 12" MIN. EMBED
AutoCAD SHX Text
1-HTT5 THIS SIDE OF F3 w/ ~0" ALLTHREAD, DRILL &EPOXY 12" MIN. EMBED
AutoCAD SHX Text
A01
AutoCAD SHX Text
A02
AutoCAD SHX Text
A03
AutoCAD SHX Text
A04
AutoCAD SHX Text
A05
AutoCAD SHX Text
A06
AutoCAD SHX Text
A07
AutoCAD SHX Text
A08
AutoCAD SHX Text
HJ10
AutoCAD SHX Text
HJ10A
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5A
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5A
AutoCAD SHX Text
A09
AutoCAD SHX Text
A13
AutoCAD SHX Text
A13
AutoCAD SHX Text
A13
AutoCAD SHX Text
A13
AutoCAD SHX Text
A11A
AutoCAD SHX Text
A14
AutoCAD SHX Text
A15
AutoCAD SHX Text
A16
AutoCAD SHX Text
A17
AutoCAD SHX Text
A18
AutoCAD SHX Text
A19
AutoCAD SHX Text
A20
AutoCAD SHX Text
B03
AutoCAD SHX Text
B04
AutoCAD SHX Text
B05
AutoCAD SHX Text
HJ10
AutoCAD SHX Text
HJ10
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3C
AutoCAD SHX Text
CJ5C
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ3A
AutoCAD SHX Text
D5
AutoCAD SHX Text
D6
AutoCAD SHX Text
HJ8
AutoCAD SHX Text
HJ8
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
D7
AutoCAD SHX Text
D8
AutoCAD SHX Text
D9
AutoCAD SHX Text
E1
AutoCAD SHX Text
E2
AutoCAD SHX Text
HJ8A
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3B
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
HJ8A
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3B
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
F1
AutoCAD SHX Text
F2
AutoCAD SHX Text
HJ10
AutoCAD SHX Text
HJ10
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
CJ1
AutoCAD SHX Text
CJ3
AutoCAD SHX Text
CJ5
AutoCAD SHX Text
EJ7
AutoCAD SHX Text
F3
AutoCAD SHX Text
V6
AutoCAD SHX Text
V10
AutoCAD SHX Text
V14
AutoCAD SHX Text
V18
AutoCAD SHX Text
V22
AutoCAD SHX Text
A12(4)
AutoCAD SHX Text
A10(5)
AutoCAD SHX Text
EJ7A(4)
AutoCAD SHX Text
A11(2)
AutoCAD SHX Text
EJ5(3)
AutoCAD SHX Text
EJ5A(4)
AutoCAD SHX Text
1-HETA20 THIS SIDE OF F3
AutoCAD SHX Text
%%UPRECAST LINTEL SCHEDULE
AutoCAD SHX Text
%%U8F8-1B
AutoCAD SHX Text
%%U8F16-1B/1T
AutoCAD SHX Text
%%U8F8-0B
AutoCAD SHX Text
AT SWING DOORS, USE 2" RECESS STYLE LINTEL IF NEEDED FOR ROUGH OPENING.
AutoCAD SHX Text
LINTELS BEAR 4" MIN EACH END
AutoCAD SHX Text
'0B' DENOTES 'NO REBAR'
AutoCAD SHX Text
%%UBEARING LEGEND
AutoCAD SHX Text
BEARING @ 9'-4"
AutoCAD SHX Text
BEARING @ 13'-11"
AutoCAD SHX Text
PLAN NOTES: 1) ROOF TRUSS BEARING ELEVATION VARIES, SEE LEGEND. 2) ROOF FRAMING SHALL BE WOOD TRUSSES DESIGNED BY A DELEGATED TRUSS ENGINEER PER DESIGN CRITERIA ON SHEE S-3. 3) PROVIDE STRAPPING AT TRUSSES PER NOTES ON THIS SHEET. 4) FOR NAILING OF ROOF DECK, SEE 1 AND 2 ON S-3. 5) 8F8-1B etc, DENOTES PRECAST LINTEL ABOVE DOOR/WINDOW OPENING PER SCHEDULE THIS SHEET. 6) AT TRUSS BEARING, PROVIDE 8x8 MASONRY BOND BEAM w/ 1-#5 CONTINUOUS, SEE DETAIL 10/S-3. 7) FOR DIMENSIONS OF ROUGH OPENINGS IN MASONRY WALLS, COORDINATE WITH WINDOW/DOOR SUPPLIER. 8) PROVIDE PRESSURE TREATED BUCKS AT WINDOWS / DOORS PER DETAIL 7/S-3.
AutoCAD SHX Text
%%UROOF FRAMING PLAN
AutoCAD SHX Text
SCALE: 3/16" = 1'-0"
AutoCAD SHX Text
HOOK #5 BAR INTO TOP OF BOND BEAM
AutoCAD SHX Text
WALL ABOVE WITH BOND BEAM AT TOP
AutoCAD SHX Text
#5 VERTICAL ABOVE LINTEL ONLY WHERE NOTED ON PLAN
AutoCAD SHX Text
'1B' DENOTES 1-#5 BOTTOM WITH 7" HOOK EACH END
AutoCAD SHX Text
8" PRECAST LINTEL
AutoCAD SHX Text
1-#5 TOP
AutoCAD SHX Text
1-#5 BOTTOM
AutoCAD SHX Text
INSTALL META16 AT ALL TRUSSES TO 1450 lb UPLIFT. FOR HIGHER UPLIFTS, SEE NOTES ON PLAN.
AutoCAD SHX Text
NOTES: 1) PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE AND SUITABLE FOR THE GEOMETRY. EMBED STRAP ON ~C OF WALL. 2) CONNECTORS ARE SIMPSON STRONG TIE. ALL CONNECTORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTRUCTIONS. SUBSTITUTIONS MUST BE APPROVED IN WRITING BY THE ENGINEER OF RECORD. 3) WHERE EMBEDDED STRAPS ARE MISSING, OR MIS-LOCATED, INSTALL RETROFIT STRAP PER 2/S-3.
AutoCAD SHX Text
12-0.162X3~8", EMBED 4"
AutoCAD SHX Text
10-0.148X1~8", EMBED 4"
AutoCAD SHX Text
10-0.148X1~8", EMBED 4"
AutoCAD SHX Text
9-0.148X1~8"", EMBED 4"
AutoCAD SHX Text
14-0.162X3~8", EMBED 4"
AutoCAD SHX Text
12-0.162X3~8", EMBED 4"
AutoCAD SHX Text
FASTENER
AutoCAD SHX Text
8-0.148x1~8", EMBED 4"
AutoCAD SHX Text
TRUSS STRAPPING TO MASONRY
AutoCAD SHX Text
(2)HHETA12 TO 40
AutoCAD SHX Text
(2)HETA16 TO 40
AutoCAD SHX Text
(2)META16 TO 40
AutoCAD SHX Text
(2)META16 TO 40
AutoCAD SHX Text
(1)HHETA16 TO 40
AutoCAD SHX Text
2365 (2 PLY)
AutoCAD SHX Text
2365 (2 PLY)
AutoCAD SHX Text
1795 (2 PLY)
AutoCAD SHX Text
1875 (1 PLY)
AutoCAD SHX Text
2120
AutoCAD SHX Text
(1)HETA16 TO 40
AutoCAD SHX Text
(1)META16 TO 40
AutoCAD SHX Text
CONNECTOR
AutoCAD SHX Text
MAX TRUSS UPLIFT
AutoCAD SHX Text
@ 24" OC (LBS)
AutoCAD SHX Text
1810
AutoCAD SHX Text
1450
AutoCAD SHX Text
R4-021020
AutoCAD SHX Text
10690/SYP 10690/SPF
AutoCAD SHX Text
4670/SYP 4015/SPF
AutoCAD SHX Text
4235/SYP 3640/SPF
AutoCAD SHX Text
3965/SYP 3330/SPF
AutoCAD SHX Text
5445/SYP 5360/SPF
AutoCAD SHX Text
10790/SYP 10790/SPF
AutoCAD SHX Text
HTT5
AutoCAD SHX Text
(1)HGT-2
AutoCAD SHX Text
HTT4
AutoCAD SHX Text
MGT (2 PLY)
AutoCAD SHX Text
HTT5KT
AutoCAD SHX Text
(1)HGT-3
AutoCAD SHX Text
16-0.148x3" TO GIRDER,
AutoCAD SHX Text
18-0.162X2~8", ~0" ATR, EPOXY 12"
AutoCAD SHX Text
22-0.148X3" ATR, EPOXY 12"
AutoCAD SHX Text
26-0.148X3", ~0" ATR, EPOXY 12"
AutoCAD SHX Text
26-SD#10x2~8, ~0" ATR, EPOXY 18"
AutoCAD SHX Text
16-0.148X3" TO GIRDER,
AutoCAD SHX Text
(2)~w" ATR, EPOXY 12"
AutoCAD SHX Text
(2)~w" ATR, EPOXY 12"
AutoCAD SHX Text
24-10dx1~8"
AutoCAD SHX Text
INSTALL AT ALL TRUSSES TO 840 lb UPLIFT. FOR HIGHER UPLIFTS, SEE NOTES ON PLAN.
AutoCAD SHX Text
(1)HTS20 to 30
AutoCAD SHX Text
(4)HTS20 to 30
AutoCAD SHX Text
(3)HTS20 to 30
AutoCAD SHX Text
(2)HTS20 to 30
AutoCAD SHX Text
NOTES: 1) PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE. 2) CONNECTORS ARE SIMPSON STRONG TIE. ALL CONNECTORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTRUCTIONS.
AutoCAD SHX Text
2250
AutoCAD SHX Text
4500
AutoCAD SHX Text
3375
AutoCAD SHX Text
1125
AutoCAD SHX Text
24-10dx1~8"
AutoCAD SHX Text
24-10dx1~8"
AutoCAD SHX Text
24-10dx1~8"
AutoCAD SHX Text
(1)MTS16 to 20
AutoCAD SHX Text
(3)MTS16 to 20
AutoCAD SHX Text
(2)MTS16 to 20
AutoCAD SHX Text
CONNECTOR
AutoCAD SHX Text
TRUSS STRAPPING TO STUD WALL/WOOD BEAM
AutoCAD SHX Text
@ 24" OC (LBS)
AutoCAD SHX Text
MAX TRUSS UPLIFT
AutoCAD SHX Text
850
AutoCAD SHX Text
2550
AutoCAD SHX Text
1700
AutoCAD SHX Text
14-10dx1~8"
AutoCAD SHX Text
14-10dx1~8"
AutoCAD SHX Text
14-10dx1~8"
AutoCAD SHX Text
FASTENER
AutoCAD SHX Text
R4-021020
AutoCAD SHX Text
At Exterior Stud Walls and Gable Ends with Wall Sheathing, apply plaster over metal lath over water resistive barrier as follows: Plaster R703.6.2: 3-coat 7/8" thick portland cement based : 3-coat 7/8" thick portland cement based thick portland cement based plaster per ASTM C926. Metal Lath R703.6.1: Self furring paper backed 2.5lb diamond : Self furring paper backed 2.5lb diamond mesh metal lath per ASTM C847, G60 galvanized, fastened per ASTM C1063 with 1-1/2” long, 11 gage nails with 7/16” long, 11 gage nails with 7/16” head (roofing nails) at 7” oc, or 1-1/2” long, 16 gage staples oc, or 1-1/2” long, 16 gage staples long, 16 gage staples at 6” oc, into the framing members (ie, the nails or staples oc, into the framing members (ie, the nails or staples must align with and penetrate 3/4” into the framing studs). into the framing studs). Water Resistive Barrier (WRB) R703.6.3: Water-resistive : Water-resistive vapor-permeable barrier with a performance at least equivalent to 2 layers of Grade D paper. The individual layers shall be installed independently. An approved house wrap may be used for the 1st layer and metal lath with approved paper backing may be the 2nd layer (Note: ZIP wall sheathing with seam tape qualifies as the first layer).
AutoCAD SHX Text
HUC26-2 HANGER @ CJ3A w/ (2)~4x1~w TAPCONS TO MASONRY, FILL HANGER WITH BLOCKING
AutoCAD SHX Text
2-HETA20 @ A01
AutoCAD SHX Text
S-2
AutoCAD SHX Text
2
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
DWB/GH
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/6/20
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
DR 11960
AutoCAD SHX Text
SHEET OF 4
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
MODEL 2221 M
AutoCAD SHX Text
174 VERAZA COURT VENICE, FLORIDA LOT: 340 BLOCK: SUBDIVISION: TOSCANA III & IV 60s
AutoCAD SHX Text
FOR BUILDERS FIRST SOURCE TRUSS, 160 MPH, EXPOSURE C, M ELEVATION, 3 CAR, JOB # MASTER, DATE DRAWN: 08/11/20, DATE PRINTED: 08/11/20, REVISED: NONE
AutoCAD SHX Text
3 CAR GARAGE
Ralph
Seal
Ralph
Signature Statement Square
Page 11: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01
AutoCAD SHX Text
2
AutoCAD SHX Text
10
AutoCAD SHX Text
DESIGN CRITERIA: DESIGN IN ACCORDANCE WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL 1. FLOOR & ROOF UNIFORM LOADS: FLOORS: LIVE LOAD 40 PSF, DEAD LOAD: SLAB ON GRADE ROOF: LIVE TOP CHORD 20 PSF LIVE BOTTOM CHORD 10 PSF (NON-CONCURRENT w/ TCLL) CEMENT ROOF TILE DEAD LOAD 25 PSF TOTAL SHINGLE/METAL ROOFING DEAD LOAD 15 PSF TOTAL MINIMUM DEAD LOAD FOR WIND: TC 5 PSF, BC 5 PSF DEFLECTION CRITERIA: ROOF L/240 LIVE, L/180 TOTAL 2. WIND LOADS: WIND DESIGN PER ASCE7-10 BASIC WIND SPEED (ASCE7-10) 160 MPH NOMINAL WIND SPEED (Vasd TABLE R301.2.1.3) 124 MPH BUILDING CATEGORY II IMPORTANCE FACTOR 1.00 EXPOSURE C MEAN ROOF HEIGHT 15 FT ROOF PITCH 5/12 ENCLOSURE CLASS. ENCLOSED INTERNAL PRES. COEFF. +/- 0.18 WINDOW/DOOR DESIGN WIND PRESSURE, SEE TABLE IN DETAIL 3. SOFFITS - PER R703.1.2.1, ALL SOFFITS SHALL BE CAPABLE OF RESISTING THE DESIGN PRESSURES SPECIFIED IN TABLE R301.2(2) FOR WALLS. 3. REINFORCED CONCRETE: DESIGN AS PER ACI 318-14 REQUIRED COMPRESSIVE STRENGTH AT 28 DAYS: SLAB ON GRADE f'c = 2500 PSI 3~8" MINIMUM THICKNESS REINFORCED WITH 6x6 w1.4xw1.4 WWF OR FIBERMESH. CONVENTIONAL SHALLOW FOOTINGS f'c = 2500 PSI BEAMS AND COLUMNS f'c = 3000 PSI ALL OTHER CONCRETE (U.N.O.) f'c = 3000 PSI UNLESS OTHERWISE SHOWN ON DRAWINGS, MINIMUM CONCRETE COVER FOR REINFORCING SHALL BE AS FOLLOWS: FOOTINGS 3" SLAB ON GRADE CENTERED BEAMS 1~8" COLUMNS 1~8" ALL REINFORCING STEEL SHALL BE PLACED IN ACCORDANCE WITH THE TYPICAL BENDING DIAGRAMS AND PLACING DETAILS OF ACI STANDARDS AND SPECIFICATIONS. ALL REINFORCING STEEL SHALL BE HELD SECURELY IN POSITION WITH STANDARD ACCESSORIES DURING PLACING OF CONCRETE. REINFORCING STEEL - ASTM A615 GRADE 60 FOR #3 TO #11 WELDED WIRE FABRIC - ASTM A185 SPLICES IN REINFORCING, SHALL BE 40 BAR DIAMETERS. NON-CONTACT LAP SPLICES MAY BE USED PROVIDED REINFORCING IS NOT SPACED MORE THAN 5" APART FOR #5 BARS. FORMWORK AND SHORING SHALL REMAIN IN PLACE UNTIL CONCRETE HAS REACHED AT LEAST 2/3 OF THE REQUIRED 28 DAY STRENGTH. 4. REINFORCED MASONRY: DESIGN PER ACI 530-13 REQUIRED COMPRESSIVE STRENGTHS: MASONRY WALLS f'm = 1500 PSI REINFORCING STEEL - ASTM A615 GRADE 60. SPLICES IN REINFORCING, SHALL BE 48 BAR DIAMETERS. ALL CONCRETE MASONRY UNITS SHALL BE COMPOSED OF ASTM C90, GRADE N-1 HOLLOW CONCRETE MASONRY UNITS WITH TYPE 'S' MORTAR. GROUT ALL CELLS CONTAINING VERTICAL REINFORCEMENT WITH 3000 PSI PEA ROCK CONCRETE GROUT. ALL CELLS BELOW FINISHED GRADE SHALL BE GROUTED SOLID. ALL EXTERIOR WALLS SHALL BE REINFORCED FULL HEIGHT AT DOT LOCATIONS ON PLAN. 5. DELEGATED-ENGINEERED WOOD ROOF & FLOOR TRUSSES: ALL WOOD ROOF AND FLOOR TRUSSES SHALL BE DESIGNED BY A DELEGATED TRUSS ENGINEER PER RULE 61G15-31.003 OF THE FLORIDA ADMINISTRATIVE CODE. ALL TRUSSES SHALL HAVE TEMPORARY BRACING PER "COMMENTARY AND RECOMMENDATIONS FOR HANDLING, INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES, HIB-91." FOR OTHER BRACING REQUIREMENTS, NOTIFY ENGINEER. PROVIDE PERMANENT BRACING PER TRUSS MFR. SHOP DRAWINGS. IF PERMANENT BRACING IS NOT SPECIFIED, CONTACT ENGINEER. 6. FOUNDATION: CONVENTIONAL SHALLOW CONCRETE FOOTINGS SOIL BEARING CAPACITY 2000 PSF THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING THE SUITABILITY OF THE SOIL CONDITIONS FOR THE INTENDED STRUCTURE AND ASSUMED SOIL BEARING CAPACITY. IT IS RECOMMENDED THAT A GEOTECHNICAL FIRM BE HIRED TO PERFORM A SITE EVALUATION. 7. DIMENSIONS: VERIFY ALL DIMENSIONS WITH HOUSE PLANS. SEE HOUSE PLANS, MECHANICAL, ELECTRICAL AND PLUMBING DRAWINGS FOR EMBEDS, OPENINGS, SLEEVES, ETC. WHICH ARE NOT SHOWN ON STRUCTURAL DRAWINGS. 8. MEANS AND METHODS: THE STRUCTURAL ENGINEER SHALL NOT HAVE CONTROL OR BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, PROCEDURES, OR SEQUENCES TEMPORARY BRACING, SHORING, GUYING OR OTHER MEANS TO SUPPORT STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION. FOR THE ACTS OR OMISSIONS OF THE CONTRACTOR, OR ANY OTHER PERSONS PERFORMING THE WORK OR FOR THE FAILURE OF ANY OF THEM TO CONSTRUCT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 9. SHOP DRAWINGS: SHOP DRAWINGS SHALL BE PREPARED AND SUBMITTED TO THE ENGINEER FOR REVIEW FOR ALL STRUCTURAL ELEMENTS UTILIZING PREFABRICATED COMPONENTS. ONE SET OF SIGNED & SEALED TRUSS ENGINEERING SHALL BE DELIVERED TO THE ENGINEER OF RECORD FOR THE STRUCTURE PER FLORIDA ADMINISTRATIVE CODE 61G15-30.005 AND 61G15-31.003.
AutoCAD SHX Text
3
AutoCAD SHX Text
8
AutoCAD SHX Text
7
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
NOTES: 1) PROVIDE SAWCUTS TO CREATE APPROXIMATE 20' X 20' MAXIMUM SQUARES. 2) SAWCUT CONCRETE SLAB WITHIN 4 TO 12 HOURS OF CONCRETE PLACEMENT.
AutoCAD SHX Text
~w" DEEP SAWCUT w/ ELASTOMERIC SEALANT
AutoCAD SHX Text
SLAB ON GRADE, SEE PLAN
AutoCAD SHX Text
%%USLAB SAWCUT DETAIL
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%UCORNER BARS
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%USTEP FOOTING
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
3" COVER
AutoCAD SHX Text
MAINTAIN FOOTING WIDTH & DEPTH AT ALL VERT. AND HORIZ. SEGMENTS
AutoCAD SHX Text
FOOTING REINF., SEE PLAN. LAP 40 BAR DIAMETERS
AutoCAD SHX Text
MAINTAIN RUN TO RISE OF 2:1 OR MORE
AutoCAD SHX Text
%%UFOOTING
AutoCAD SHX Text
%%UPLAN VIEW
AutoCAD SHX Text
FOOTING REINF., SEE PLAN
AutoCAD SHX Text
LAP CORNER BARS 40 BAR DIAMETERS
AutoCAD SHX Text
CONCRETE FOOTING, SEE PLAN
AutoCAD SHX Text
%%URETROFIT UPLIFT CONNECTOR SCHEDULE
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UCORNER
AutoCAD SHX Text
%%UCORNER BAR DETAIL IN BOND BEAMS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
#5 CORNER BAR, 25"x25"
AutoCAD SHX Text
MASONRY BOND BEAM, TYPICAL
AutoCAD SHX Text
%%UINTERSECTION
AutoCAD SHX Text
6
AutoCAD SHX Text
NOTE: THIS BUCK FASTENING DETAIL IS INTENDED FOR FLANGED WINDOW/DOOR PRODUCTS THAT FASTEN THRU THE FLANGE WITH WOOD SCREWS TO THE BUCK. FOR WINDOW/DOOR PRODUCTS THAT DO NOT HAVE A FLANGE AND FASTEN INSTEAD OUTWARD THRU THE FRAME, USE MASONRY SCREWS PER MFR. THAT ARE LONG ENOUGH TO PENETRATE 2-1/4" INTO THE MASONRY. IN THIS CASE, THE BUCK MATERIAL IS SIMPLY A SPACER AND MAY BE 1x4 OR 1x6 OR OMITTED ENTIRELY AND THE SPACER MAY BE TACKED IN PLACE WITH MASONRY NAILS OR PINS.
AutoCAD SHX Text
%%UBUCK FASTENING
AutoCAD SHX Text
8" CMU WALLS
AutoCAD SHX Text
~4"x3~w" TAPCON @ 24" OC, 3 SCREWS MIN. (SEE NOTE)
AutoCAD SHX Text
2x4 or 2x6 P.T. BUCK @ FLANGED WINDOWS (SEE NOTE)
AutoCAD SHX Text
8" CMU, SEE PLAN FOR REINFORCING
AutoCAD SHX Text
%%UGARAGE DOOR
AutoCAD SHX Text
~8"~D EXPANSION BOLT, 4" MIN. EMBEDMENT, SPACE 24" OC AND 12" FROM TOP & BOT.
AutoCAD SHX Text
2x8 OR 2x6 P.T. SYP#2
AutoCAD SHX Text
2x2x~2" WASHER
AutoCAD SHX Text
APPROVED ISOLATION PLATE
AutoCAD SHX Text
8"x8" CONTINUOUS MASONRY BOND BEAM w/ 1-#5, GROUT SOLID. PROVIDE CORNER BARS PER DETAIL 8/S-3.
AutoCAD SHX Text
#5 VERT. IN GROUTED CELL AT DOT LOCATIONS ON PLAN (48" OC MAX EXTERIOR)
AutoCAD SHX Text
12
AutoCAD SHX Text
EMBEDDED STRAP AT EACH ROOF TRUSS, SEE ROOF PLAN. BREAK OUT WEB OF BLOCK AS NEEDED TO PROPERLY LOCATE EACH STRAP.
AutoCAD SHX Text
#5 VERTICAL SHALL HAVE 7" STANDARD HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
%%UTRUSS STRAP TO BOND BEAM
AutoCAD SHX Text
SOFFITS SHALL MEET WIND DESIGN PRESSURES PER R703.1.2.1. FOR FIELD FRAMING, SEE TABLE 2/S-3.
AutoCAD SHX Text
WOOD TRUSSES @ 24" OC, DESIGNED BY DELEGATED TRUSS ENGINEER
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE 2/S-3
AutoCAD SHX Text
5
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
TRUSS BEARING
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
2x_ SUBFASCIA w/ 2-16d TO EACH TRUSS
AutoCAD SHX Text
9
AutoCAD SHX Text
8"x8" BOND BEAM w/ 1-#5
AutoCAD SHX Text
#5 VERTICAL IN GROUTED CELL AT DOT LOCATIONS ON PLAN
AutoCAD SHX Text
7" STANDARD HOOK INTO TOP OF BOND BEAM (MAY USE 7"x25" BENT BAR)
AutoCAD SHX Text
#5 VERT. AT INTERSECTION OF BOND BEAM w/ 7" HOOK AT TOP
AutoCAD SHX Text
HOOK BAR INTO TOP OF UPPER BOND BEAM
AutoCAD SHX Text
%%USTEPPED BOND BEAM & REINFORCING
AutoCAD SHX Text
MASONRY WALL
AutoCAD SHX Text
VERTICAL BAR IN GROUTED CELL, SEE PLAN
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
UPPER BOND BEAM, SEE PLAN
AutoCAD SHX Text
BEARING
AutoCAD SHX Text
HOOK OR CORNER BAR
AutoCAD SHX Text
VERTICAL BOND BEAM, 8"x8" CMU w/ #5 VERTICAL
AutoCAD SHX Text
LINTEL AT LANAI OR ENTRY, '8F16-1B/1T' (8"x16" FILLED SOLID, 1#5 BOTTOM, 1-#5 TOP)
AutoCAD SHX Text
IN ZONE 5, MANUFACTURED SOFFIT PRODUCTS MAY REQUIRE ADDITIONAL BATTONS OR FASTENING PER MFR ENGINEERING SPEC SHEETS TO MEET THE PRESSURE REQUIREMENTS.
AutoCAD SHX Text
* ON IRREGULAR SHAPED BUILDINGS, THERE IS NO GUIDANCE IN THE CODE FOR HOW FAR A CORNER MUST PROTRUDE FROM THE MAIN BUILDING TO BE CONSIDERED 'ZONE 5'. WE HAVE CHOSEN >15'. THIS IS SUBJECT TO JUDGEMENT CALL BY THE AUTHORITY HAVING JURISDICTION.
AutoCAD SHX Text
1) TABLE MAY BE USED FOR ANY SIZE WINDOW OR DOOR IN EACH TYPE. 2) USE "INTERIOR ZONE 4" PRESSURES UNLESS WINDOW OR DOOR IS LOCATED WITHIN THE "END ZONE 5" (SEE DIAGRAM BELOW), THEN USE THE HIGHER PRESSURES UNDER THE "END ZONE 5" COLUMN. 3) ALL GLASS / GLAZING SHALL BE IMPACT RATED OR USE IMPACT RATED SHUTTERS. 4) SUBMIT PRODUCT APPROVALS TO THE BUILDING DEPARTMENT AS REQUIRED BY THE LOCAL JURISDICTION. 5) MANUFACTURED SOFFIT PRODUCTS SHALL BE INSTALLED PER MFR ENGINEERING SPEC SHEETS.
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
MEASURED FROM
AutoCAD SHX Text
FACE OF WALL
AutoCAD SHX Text
END ZONE 5 PRESSURES OCCUR AT "PRIMARY" OUTSIDE CORNERS OF BUILDING (BOLD LINES)
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
4
AutoCAD SHX Text
INTERIOR ZONE 4 PRESSURES
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
5
AutoCAD SHX Text
5
AutoCAD SHX Text
4
AutoCAD SHX Text
5'-0"
AutoCAD SHX Text
WIDTH = ______
AutoCAD SHX Text
END
AutoCAD SHX Text
ZONE
AutoCAD SHX Text
(SEE PLAN FOR OTHER SPECIFIC PRESSURES)
AutoCAD SHX Text
SHEATHING SCHEDULE
AutoCAD SHX Text
FLOOR
AutoCAD SHX Text
N/A
AutoCAD SHX Text
EXTERIOR STUD WALL
AutoCAD SHX Text
ROOF
AutoCAD SHX Text
EXTERIOR CEILING AND SOFFIT
AutoCAD SHX Text
OPTIONS: 1) 1x4 STRIPPING @ 16"OC w/ 2-8d NAILS TO EACH TRUSS, ~0" EXTERIOR GYPBOARD CEILING, FASTEN w/8d NAILS OR 1~0" DRYWALL SCREWS @ 6"OC EDGE & FIELD. 2) ~6" BC PLYWOOD NAILED w/ 6d COMMON @ 6" OC EDGE & FIELD. 3) VINYL OR ALUMINUM PERFORATED SOFFIT INSTALLED PER MANUFACTURER INSTRUCTIONS TO MEET WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
A.P.A. RATED SHEATHING, EXPOSURE 1, SPAN RATING 24/16 OR BETTER. FASTEN WITH 8d RING SHANK NAILS @ 6" O.C. EDGE AND 6" O.C. FIELD.
AutoCAD SHX Text
(RING SHANK NAILS PER R803.2.3.1: 0.113" NOMINAL SHANK DIAMETER, RING DIA. OF 0.012" OVER SHANK DIAMETER, 16 TO 20 RINGS PER INCH, 0.280" DIAMETER FULL ROUND HEAD, 2" NAIL LENGTH)
AutoCAD SHX Text
NOTE: EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED : EXTERIOR CEILINGS AND SOFFITS 1) AND 2) SPECIFIED HERE MEET THE DESIGN WIND PRESSURES PER R703.1.2.1.
AutoCAD SHX Text
7/16" ZIP SYSTEM WALL SHEATHING BY HUBER ENGINEERED WOODS LLC, NAILED W/ 8d COMMON WIRE @ 6" O.C. EDGE AND 6" O.C. FIELD. PROVIDE 2x4 BLOCKING AT ALL JOINTS. INSTALL SHEATHING AND SEAM TAPE IN STRICT ACCORDANCE WITH MFR. WRITTEN INSTRUCTIONS.
AutoCAD SHX Text
(WHEN ~8" ZIP BRAND ROOF SHEATHING IS USED, H-CLIPS ARE NOT REQUIRED) REQUIRED)
AutoCAD SHX Text
8" MASONRY
AutoCAD SHX Text
WIND PRESSURES PER ASCE7-10, 160 MPH, EXPOSURE C, AND CONVERTED
AutoCAD SHX Text
TO ALLOWABLE STRESS DESIGN PRESSURES USING 0.6W LOAD FACTOR.
AutoCAD SHX Text
WINDOW/DOOR/SOFFIT DESIGN WIND PRESSURES
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
INTERIOR ZONE 4
AutoCAD SHX Text
(Vasd=124 MPH, RISK CAT II, ENCLOSED, kd=0.85, h=15')
AutoCAD SHX Text
+33.5 -36.3
AutoCAD SHX Text
16' OR 18' GARAGE DOORS
AutoCAD SHX Text
TYPICAL WINDOWS & DOORS
AutoCAD SHX Text
8' OR 9' GARAGE DOORS
AutoCAD SHX Text
TYPE
AutoCAD SHX Text
SOFFIT
AutoCAD SHX Text
+28.2 -31.5
AutoCAD SHX Text
+29.4 -33.3
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
END ZONE 5
AutoCAD SHX Text
+33.5 -44.8
AutoCAD SHX Text
NOTES: 1) WHERE EMBEDDED STRAP IS MISSING OR MIS-LOCATED, PROVIDE A STRAP FROM THE ABOVE LIST AT EACH ROOF TRUSS BEARING POINT, BASED ON THE TRUSS UPLIFT VALUES IN THE SIGNED AND SEALED TRUSS DESIGN PACKAGE. 2) CONNECTORS ARE SIMPSON STRONG TIE. ALL CONNECTORS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH SIMPSON PRINTED INSTRUCTIONS.
AutoCAD SHX Text
1-MTSM16 or 20
AutoCAD SHX Text
2-LGT2
AutoCAD SHX Text
HGT-2/3
AutoCAD SHX Text
2-HTSM16 or 20
AutoCAD SHX Text
CONNECTOR
AutoCAD SHX Text
1-HTSM16 or 20
AutoCAD SHX Text
RETROFIT STRAPS TO CONCRETE/MASONRY
AutoCAD SHX Text
TO 10530
AutoCAD SHX Text
TRUSS UPLIFT (LBS)
AutoCAD SHX Text
TO 840
AutoCAD SHX Text
TO 4300
AutoCAD SHX Text
TO 2090
AutoCAD SHX Text
TO 3480
AutoCAD SHX Text
TO 1045
AutoCAD SHX Text
@ 24" OC
AutoCAD SHX Text
HTT16
AutoCAD SHX Text
7-10dx1~8", 4-~4x2~4 TITEN
AutoCAD SHX Text
EPOXY 12" EMBED WITH SIMPSON SET.
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 TITEN
AutoCAD SHX Text
8-10dx1~8", 4-~4x2~4 TITEN
AutoCAD SHX Text
16-16d, 7-~4"x2~4" TITEN
AutoCAD SHX Text
18-16d, ~0"~D ALLTHREAD, DRILL
AutoCAD SHX Text
& EPOXY 10" EMBED w/ SIMPSON SET.
AutoCAD SHX Text
TWO ~w"~D ALTHREAD, DRILL &
AutoCAD SHX Text
1
AutoCAD SHX Text
SCALE: NTS
AutoCAD SHX Text
%%UROOF DECK NAILING PATTERN
AutoCAD SHX Text
%%UTYPICAL
AutoCAD SHX Text
%%UPLAN
AutoCAD SHX Text
%%UHOUSE
AutoCAD SHX Text
8d RING SHANK NAILS 6" O.C. EDGE AND 6" OC FIELD. ENSURE THAT ALL NAILS PENETRATE THE TOP CHORD OF THE TRUSS WITHOUT SPLITTING.
AutoCAD SHX Text
(IN >165 MPH ZONE ONLY) 4" O.C. EDGE NAILING IN 5'-0" BAND AT GABLE ENDS
AutoCAD SHX Text
11
AutoCAD SHX Text
2x4 OUTLOOKER
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE
AutoCAD SHX Text
H2.5A CLIP @ EA. OUTLOOKER TO TRUSS
AutoCAD SHX Text
TRUSS TOP CHORD, DROP 3~8"
AutoCAD SHX Text
2x4 BLOCK AT
AutoCAD SHX Text
%%UOUTLOOKER DETAIL AT DROP GABLE
AutoCAD SHX Text
SCALE: N.T.S.
AutoCAD SHX Text
SHEATHING JOINT
AutoCAD SHX Text
3-12d TOE NAILS
AutoCAD SHX Text
2x4 BLOCKING
AutoCAD SHX Text
BRACE VERTICAL MEMBERS
AutoCAD SHX Text
MASONRY WALL, SEE PLAN
AutoCAD SHX Text
MID WALL WEEP SCREED
AutoCAD SHX Text
2x6 PT SILL w/ ~8"x6" ~8"x6" ANCHOR BOLTS @ 32" O.C. w/ 2" WASHER
AutoCAD SHX Text
12d NAILS AT TRUSS BOTTOM CHORD TO SILL @ 8" O.C.
AutoCAD SHX Text
NO GABLE END BRACING REQUIRED
AutoCAD SHX Text
%%UUSED ONLY ON 'L'
AutoCAD SHX Text
S-3
AutoCAD SHX Text
3
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
DWB/GH
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/6/20
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
DR 11960
AutoCAD SHX Text
SHEET OF 4
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
MODEL 2221 M
AutoCAD SHX Text
174 VERAZA COURT VENICE, FLORIDA LOT: 340 BLOCK: SUBDIVISION: TOSCANA III & IV 60s
AutoCAD SHX Text
FOR BUILDERS FIRST SOURCE TRUSS, 160 MPH, EXPOSURE C, M ELEVATION, 3 CAR, JOB # MASTER, DATE DRAWN: 08/11/20, DATE PRINTED: 08/11/20, REVISED: NONE
AutoCAD SHX Text
3 CAR GARAGE
Ralph
Seal
Ralph
Signature Statement Square
Page 12: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01
AutoCAD SHX Text
1
AutoCAD SHX Text
APPROVED ISOLATION PLATE
AutoCAD SHX Text
8"x8" CONTINUOUS MASONRY BOND BEAM w/ 1-#5, GROUT SOLID. PROVIDE CORNER BARS PER DETAIL 6/S-3
AutoCAD SHX Text
#5 VERT. IN GROUTED CELL AT DOT LOCATIONS ON PLAN (48" OC MAX EXTERIOR)
AutoCAD SHX Text
12
AutoCAD SHX Text
EMBEDDED STRAP AT EACH ROOF TRUSS, SEE ROOF PLAN. BREAK OUT WEB OF BLOCK AS NEEDED TO PROPERLY LOCATE EACH STRAP
AutoCAD SHX Text
#5 VERTICAL SHALL HAVE 7" STANDARD HOOK INTO TOP OF BOND BEAM
AutoCAD SHX Text
%%UFULL HEIGHT WALL SECTION
AutoCAD SHX Text
SOFFITS SHALL MEET WIND DESIGN PRESSURES PER R703.1.2.1. FOR FIELD FRAMING, SEE TABLE 2/S-3
AutoCAD SHX Text
WOOD TRUSSES @ 24" OC, DESIGNED BY DELEGATED TRUSS ENGINEER
AutoCAD SHX Text
ROOF SHEATHING, SEE SCHEDULE 2/S-3
AutoCAD SHX Text
5
AutoCAD SHX Text
TRUSS BEARING
AutoCAD SHX Text
SEE PLAN
AutoCAD SHX Text
FINISHED GRADE, SEE SITE PLAN
AutoCAD SHX Text
3" CLEAR COVER TO REINFORCING
AutoCAD SHX Text
EMBED DOWELS 5" WITH 10" STD HOOK
AutoCAD SHX Text
DOWEL TO MATCH WALL REINFORCING, LAP 25"
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
2x_ SUBFASCIA w/ 2-16d TO EACH TRUSS
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
%%UKNEEWALL @ ENTRY 'L'
AutoCAD SHX Text
+9'-4"
AutoCAD SHX Text
META16 AT LOWER TRUSS
AutoCAD SHX Text
MASONRY WALL & BOND BEAM, SEE PLANS
AutoCAD SHX Text
B01 OR B02 TRUSS
AutoCAD SHX Text
2x4 DOUBLE TOP PLATE w/ SPH4 @ 16" O.C.
AutoCAD SHX Text
ROOF SHEATHING PER SCHEDULE 2/S-3
AutoCAD SHX Text
MTS16 STRAP AT UPPER TRUSS
AutoCAD SHX Text
TRUSS D1
AutoCAD SHX Text
+13'-11"
AutoCAD SHX Text
2x4 SPF #2 @ 16" OC
AutoCAD SHX Text
WALL SHEATHING PER 2/S-3
AutoCAD SHX Text
2
AutoCAD SHX Text
2x4 PT SILL w/ SPH4 @ 16" O.C. & ~8"x6" ANCHOR BOLTS ~8"x6" ANCHOR BOLTS @ 32" O.C. w/ 2" WASHER
AutoCAD SHX Text
ROOF COVERING AS SELECTED BY BUILDER PER: FBCR905.2 ASPHALT SHINGLES FBCR905.3 CLAY AND CONCRETE TILE FBCR 905.4 METAL ROOF
AutoCAD SHX Text
MONOLITHIC FOOTING, SEE PLAN
AutoCAD SHX Text
MERGE PAD FOOTINGS WITH EDGE FOOTINGS
AutoCAD SHX Text
3
AutoCAD SHX Text
%%UKNEEWALL @ ENTRY 'M'
AutoCAD SHX Text
+9'-4"
AutoCAD SHX Text
1-META16 AT LOWER TRUSS
AutoCAD SHX Text
MASONRY WALL & BOND BEAM, SEE PLANS
AutoCAD SHX Text
TRUSS B03 TO B05
AutoCAD SHX Text
2x4 DOUBLE TOP PLATE w/ SPH4 @ 16" O.C.
AutoCAD SHX Text
ROOF SHEATHING PER SCHEDULE 2/S-3
AutoCAD SHX Text
MTS16 STRAP AT TRUSS
AutoCAD SHX Text
TRUSS E1 & E2
AutoCAD SHX Text
+13'-11"
AutoCAD SHX Text
2x4 SPF #2 @ 16" OC
AutoCAD SHX Text
WALL SHEATHING PER 2/S-3
AutoCAD SHX Text
FALSE KNEEWALL, NO STRAPS
AutoCAD SHX Text
ROOF & WALL SHEATHING PER 2/S-3
AutoCAD SHX Text
BLOCKING AT EDGE OF SHEATHING
AutoCAD SHX Text
2x_ SUBFASCIA w/ 2-16d TO EACH TRUSS
AutoCAD SHX Text
2x4 BLOCKING FOR KNEEWALL
AutoCAD SHX Text
2x4 BLOCKING FOR ROOF SHEATHING
AutoCAD SHX Text
2x4 PT SILL w/ SPH4 @ 16" O.C. & ~8"x6" ANCHOR BOLTS ~8"x6" ANCHOR BOLTS @ 32" O.C. w/ 2" WASHER
AutoCAD SHX Text
SCALE: 3/4" = 1'-0"
AutoCAD SHX Text
4
AutoCAD SHX Text
S-4
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
BY
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DESIGN/DRAWN
AutoCAD SHX Text
DWB/GH
AutoCAD SHX Text
DWB
AutoCAD SHX Text
10/6/20
AutoCAD SHX Text
VARIES
AutoCAD SHX Text
DR 11960
AutoCAD SHX Text
SHEET OF 4
AutoCAD SHX Text
DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 6th EDITION (2017) RESIDENTIAL
AutoCAD SHX Text
BUILDER:
AutoCAD SHX Text
(239) 549-4554
AutoCAD SHX Text
CA# 8829
AutoCAD SHX Text
STRUCTURAL
AutoCAD SHX Text
SYSTEMS
AutoCAD SHX Text
OF NORTH FLORIDA
AutoCAD SHX Text
1634 S.E. 47th STREET, SUITE #3
AutoCAD SHX Text
CAPE CORAL, FL 33904
AutoCAD SHX Text
STRUCTURAL ENGINEERING:
AutoCAD SHX Text
MODEL 2221 M
AutoCAD SHX Text
174 VERAZA COURT VENICE, FLORIDA LOT: 340 BLOCK: SUBDIVISION: TOSCANA III & IV 60s
AutoCAD SHX Text
FOR BUILDERS FIRST SOURCE TRUSS, 160 MPH, EXPOSURE C, M ELEVATION, 3 CAR, JOB # MASTER, DATE DRAWN: 08/11/20, DATE PRINTED: 08/11/20, REVISED: NONE
AutoCAD SHX Text
3 CAR GARAGE
Ralph
Seal
Ralph
Signature Statement Square
Page 13: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

6904 Parke East Blvd.Tampa, FL 33610-4115

MiTek USA, Inc. RE: 2221_M_160_C_3-CAR -

Design Code: FBC2017/TPI2014Wind Code: ASCE 7-10 Wind Speed: 160 mphRoof Load: 50.0 psf

Design Program: MiTek 20/20 8.2

1 of 2

This package includes 53 individual, Truss Design Drawings and 0 Additional Drawings.With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheetconforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.

General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show SpecialLoading Conditions):

Floor Load: N/A psf

Site Information:

Lot/Block: MASTERCustomer Info: DR Horton Project Name: 2221 M 160 C 3-CAR Model: 2221

Subdivision: MASTERAddress: MASTER, N/A

State: FloridaCity: MASTER

Name Address and License # of Structural Engineer of Record, If there is one, for the building.Name: License #: Address: City: State:

August 11,2020

Albani, Thomas

The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource (Punta Gorda, FL).

Truss Design Engineer's Name: Albani, ThomasMy license renewal date for the state of Florida is February 28, 2021.

Lumber design values are in accordance with ANSI/TPI 1 section 6.3These truss designs rely on lumber values established by others.

IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek or TRENCO. Any project specific information included is for MiTek's or TRENCO's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek or TRENCO has not independently verified the applicability of the design parameters or the designs for any particular building. Before use,the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2.

No. Seal# Truss Name1 T20992379 A01

Date8/11/20

2 T20992380 A02 8/11/203 T20992381 A03 8/11/204 T20992382 A04 8/11/205 T20992383 A05 8/11/206 T20992384 A06 8/11/207 T20992385 A07 8/11/208 T20992386 A08 8/11/209 T20992387 A10 8/11/2010 T20992388 A11 8/11/2011 T20992389 A12 8/11/2012 T20992390 A13 8/11/2013 T20992391 A14 8/11/2014 T20992392 A15 8/11/20

No. Seal# Truss Name15 T20992393 A16

Date8/11/20

16 T20992394 A17 8/11/2017 T20992395 A18 8/11/2018 T20992396 A19 8/11/2019 T20992397 A20 8/11/2020 T20992398 B03 8/11/2021 T20992399 B04 8/11/2022 T20992400 B05 8/11/2023 T20992401 CJ1 8/11/2024 T20992402 CJ3 8/11/2025 T20992403 CJ3A 8/11/2026 T20992404 CJ3B 8/11/2027 T20992405 CJ3C 8/11/2028 T20992406 CJ5 8/11/20

This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature.Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies

Page 14: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

6904 Parke East Blvd.Tampa, FL 33610-4115

MiTek USA, Inc. RE: 2221_M_160_C_3-CAR -

2 of 2

Site Information:

Lot/Block: MASTERCustomer Info: DR Horton Project Name: 2221 M 160 C 3-CAR Model: 2221

Subdivision: MASTERAddress: MASTER, N/A

State: FloridaCity: MASTER

No. Seal# Truss Name29 T20992407 CJ5A

Date8/11/20

30 T20992408 CJ5C 8/11/2031 T20992409 D5 8/11/2032 T20992410 D6 8/11/2033 T20992411 D7 8/11/2034 T20992412 D8 8/11/2035 T20992413 D9 8/11/2036 T20992414 E1 8/11/2037 T20992415 E2 8/11/2038 T20992416 EJ5 8/11/2039 T20992417 EJ5A 8/11/2040 T20992418 EJ7 8/11/2041 T20992419 EJ7A 8/11/2042 T20992420 F1 8/11/2043 T20992421 F2 8/11/2044 T20992422 F3 8/11/2045 T20992423 HJ8 8/11/2046 T20992424 HJ8A 8/11/2047 T20992425 HJ10 8/11/2048 T20992426 HJ10A 8/11/2049 T20992427 V6 8/11/2050 T20992428 V10 8/11/2051 T20992429 V14 8/11/2052 T20992430 V18 8/11/2053 T20992431 V22 8/11/20

Page 15: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A01

Truss Type

Hip Girder

Qty

1

Ply

2

Job Reference (optional)

T20992379

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:00 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-EYcHxAAMwSeNirKwRfOTpJpe57QT3Gpnkwb4lqyouHH

Scale = 1:73.4

9

10

11

3 4 5 6 7 8

1 2

1716 15 14 13 12

20 1918

21

25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

40 41 42 43 44 45 46 47 48 49

50 51 52

5x6

7x10

4x6

5x6

4x6

2x4

2x4

5x12

5x8

2x4 4x12

2x4 3x4

5x8

7x10

5x6

7x10

2x4 5x8

2x4

2x4

3x8

6x8

5x6

5x6

4x6

15-4-0

1-2-81-2-8

1-6-8

0-4-0

3-6-82-0-0

3-10-80-4-0

7-0-03-1-8

10-11-43-11-4

13-10-82-11-4

14-10-81-0-0

16-2-8

1-4-016-6-8

0-4-0

19-10-83-4-0

20-1-40-2-12

25-1-45-0-0

30-4-05-2-12

35-5-05-1-0

40-10-85-5-8

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

3-10-82-4-0

7-0-03-1-8

10-11-43-11-4

14-10-83-11-4

16-2-81-4-0

19-10-83-8-0

24-11-85-1-0

25-1-40-1-12

30-4-05-2-12

35-5-05-1-0

40-10-85-5-8

42-5-01-6-8

0-6-

3

3-5-

3

0-6-

3

1-0-

0

3-5-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-1-4,0-2-1], [1:0-6-10,Edge], [2:0-0-0,0-4-9], [2:0-5-12,0-0-7], [2:0-0-11,0-1-10], [3:0-7-12,0-2-8], [6:0-3-0,0-3-0], [9:0-3-0,0-2-4], [11:0-5-7,0-3-0],[13:0-3-8,0-4-8], [14:0-5-0,0-4-8], [18:0-2-8,0-2-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.730.320.48

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.15

-0.18-0.06

(loc)13-14

211

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 537 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

1-3: 2x6 SP No.2BOT CHORD 2x6 SP No.2 *Except*

22-23: 2x4 SP No.3, 2-18: 2x4 SP No.2WEBS 2x4 SP No.3 *Except*

6-15: 2x6 SP No.2, 5-16: 2x8 SP 2400F 2.0ESLIDER Right 2x8 SP 2400F 2.0E 3-3-10

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:

6-0-0 oc bracing: 15-16,19-20,18-19.

REACTIONS. (size) 1=0-8-0, 16=0-8-0, 11=0-8-0Max Horz 11=97(LC 7)Max Uplift 1=-104(LC 8), 16=-2263(LC 8), 11=-1152(LC 8)Max Grav 1=552(LC 17), 16=4462(LC 1), 11=1758(LC 18)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 9-11=-3551/2281, 3-4=-674/140, 4-5=-1531/3366, 5-6=-1470/3210, 6-7=-408/707,

7-8=-3829/2627, 8-9=-3829/2627, 2-3=-730/141BOT CHORD 15-16=-1574/768, 14-15=-1970/2905, 13-14=-1972/2910, 12-13=-1972/3137,

11-12=-1977/3149, 2-20=-67/702, 19-20=-343/593, 18-19=-343/593WEBS 9-12=-111/412, 6-15=-751/1352, 15-18=-1185/1831, 6-18=-3864/2329, 4-18=-3292/1284,

4-19=0/307, 4-20=-483/1157, 3-20=-408/305, 7-15=-2981/1757, 9-13=-634/882, 7-14=-109/422, 8-13=-750/541, 7-13=-605/1086, 16-18=-4559/2415, 5-18=-624/388

NOTES-1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:

Top chords connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc.Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc, 2x4 - 1 row at 0-9-0 oc.Webs connected as follows: 2x4 - 1 row at 0-9-0 oc, 2x6 - 2 rows staggered at 0-9-0 oc, 2x8 - 2 rows staggered at 0-9-0 oc.

2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply toply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.

3) Unbalanced roof live loads have been considered for this design.4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch right exposed; Lumber DOL=1.60 plategrip DOL=1.60

5) Provide adequate drainage to prevent water ponding.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.8) Solid blocking is required on both sides of the truss at joint(s), 1.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=104, 16=2263, 11=1152.Continued on page 2

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 16: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A01

Truss Type

Hip Girder

Qty

1

Ply

2

Job Reference (optional)

T20992379

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:00 2020 Page 2 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-EYcHxAAMwSeNirKwRfOTpJpe57QT3Gpnkwb4lqyouHH

NOTES-10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 467 lb up at 35-5-0, 107 lb down and 187 lb up at

33-4-4, 107 lb down and 187 lb up at 31-4-4, 107 lb down and 187 lb up at 29-4-4, 107 lb down and 187 lb up at 27-4-4, 107 lb down and 187 lb up at 25-4-4, 107 lbdown and 187 lb up at 23-4-4, 107 lb down and 187 lb up at 21-4-4, 107 lb down and 187 lb up at 21-0-12, 107 lb down and 187 lb up at 19-0-12, 107 lb down and 187lb up at 17-0-12, 107 lb down and 187 lb up at 15-0-12, 72 lb down and 152 lb up at 13-0-12, 72 lb down and 152 lb up at 11-0-12, and 72 lb down and 152 lb up at 9-0-12, and 154 lb down and 339 lb up at 7-0-0 on top chord, and 141 lb down at 35-5-0, 60 lb down at 33-4-4, 60 lb down at 31-4-4, 60 lb down at 29-4-4, 60 lb downat 27-4-4, 60 lb down at 25-4-4, 60 lb down at 23-4-4, 60 lb down at 21-4-4, 60 lb down at 21-0-12, 60 lb down at 19-0-12, 60 lb down at 17-0-12, 60 lb down at 15-0-4, 45 lb down at 13-0-12, 45 lb down at 11-0-12, and 45 lb down at 9-0-12, and 109 lb down and 1 lb up at 7-0-12 on bottom chord. The design/selection of suchconnection device(s) is the responsibility of others.

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 9-11=-80, 3-9=-80, 1-3=-80, 11-17=-20, 2-18=-20, 1-21=-20

Concentrated Loads (lb)Vert: 3=-154(B) 12=-87(B) 19=-35(B) 20=-69(B) 4=-72(B) 9=-257(B) 26=-72(B) 28=-72(B) 29=-107(B) 30=-107(B) 31=-107(B) 32=-214(B) 33=-107(B) 34=-107(B)35=-107(B) 36=-107(B) 37=-107(B) 38=-107(B) 40=-41(B) 41=-41(B) 42=-41(B) 43=-81(B) 44=-41(B) 45=-41(B) 46=-41(B) 47=-41(B) 48=-41(B) 49=-41(B)50=-35(B) 51=-35(B)

Page 17: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A02

Truss Type

HIP

Qty

1

Ply

1

Job Reference (optional)

T20992380

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:02 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-Axk2MsBdS3u5x8UJZ3QxukuyOw3PW5c4CE4BpiyouHF

Scale = 1:73.4

8

9

10

3 4 5 6 7

1 2

1514 13 12 11

1716

18

22

23 24 25 26 27 28

2930

5x8

8x14 MT20HS

4x6

4x6

4x6

5x6

4x6

7x10 2x4

2x4

8x12

5x8

7x10

6x12 MT20HS3x6

4x12

3x4

2x4

2x4

3x8

3x4

7x10

5x6 5x6

4x6

15-4-0

1-2-81-2-8

1-6-8

0-4-0

3-6-82-0-0

3-10-80-4-0

9-0-05-1-8

13-10-84-10-8

14-10-81-0-0

16-2-8

1-4-016-6-8

0-4-0

19-10-83-4-0

26-9-26-10-10

33-5-06-7-14

40-10-87-5-8

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

3-10-82-4-0

9-0-05-1-8

12-7-33-7-3

14-10-82-3-5

16-2-81-4-0

19-10-83-8-0

26-9-26-10-10

33-5-06-7-14

40-10-87-5-8

42-5-01-6-8

0-6-

3

4-3-

3

0-6-

3

1-0-

0

4-3-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-1-4,0-2-1], [1:0-6-10,Edge], [2:0-0-0,0-4-9], [2:0-5-12,0-0-7], [2:0-0-11,0-1-10], [3:0-11-12,0-2-8], [6:0-4-0,0-3-0], [8:0-9-0,0-2-4], [10:0-4-7,0-5-0],[11:0-5-0,0-4-8], [12:0-5-0,0-4-8], [14:0-4-8,0-1-8], [16:0-2-4,0-4-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.870.480.79

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.16

-0.33-0.08

(loc)10-11

181

l/defl>999>583

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 276 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

8-10: 2x4 SP M 31, 1-3: 2x6 SP No.2BOT CHORD 2x6 SP No.2 *Except*

19-20: 2x4 SP No.3, 2-16: 2x4 SP No.2WEBS 2x4 SP No.3 *Except*

6-13: 2x6 SP No.2, 5-14: 2x8 SP 2400F 2.0ESLIDER Right 2x8 SP 2400F 2.0E 4-4-10

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-1-7 oc purlins.BOT CHORD Rigid ceiling directly applied or 5-0-14 oc bracing.WEBS 1 Row at midpt 7-13

REACTIONS. (size) 1=0-8-0, 14=0-8-0, 10=0-8-0Max Horz 10=123(LC 11)Max Uplift 1=-75(LC 12), 14=-1335(LC 12), 10=-791(LC 12)Max Grav 1=449(LC 17), 14=2765(LC 1), 10=1103(LC 22)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 8-10=-1887/2016, 4-5=-1051/1962, 5-6=-1041/1912, 6-7=-23/554, 7-8=-1423/1822,

2-3=-260/162BOT CHORD 13-14=-959/632, 12-13=-1567/1417, 11-12=-1716/1586, 10-11=-1716/1586, 2-17=-36/373,

16-17=-859/760WEBS 8-11=-464/355, 8-12=-292/160, 7-12=-377/378, 7-13=-1704/1496, 6-13=-893/814,

13-16=-856/803, 6-16=-2038/1875, 3-17=-531/399, 14-16=-2853/2060, 4-17=-488/1074, 4-16=-1483/745

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 9-0-0, Exterior(2) 9-0-0 to13-2-15, Interior(1) 13-2-15 to 33-5-0, Exterior(2) 33-5-0 to 37-7-15, Interior(1) 37-7-15 to 42-1-0 zone; cantilever left and rightexposed ; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Solid blocking is required on both sides of the truss at joint(s), 1.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)

14=1335, 10=791.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 18: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A03

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992381

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:34:26 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-oPrrLuHozinyRQTnFc9dcwjW1_dum7H1a1xJQqyotch

Scale = 1:74.1

1

2

3

4 5 6 7 8

9

10 11

22 21 19 18 1615

1413

12

25

26 27 28 29

30

31

23 20 17

3x6

3x4

3x4

5x6

5x6

4x6

4x10 MT20HS

4x6

7x10

2x4 5x6

3x4

5x8

5x6 2x4 5x8

4x6

6x8 5x8

4x6 4x6

4x6

2x4

1-2-81-2-8

4-10-153-8-7

11-0-06-1-1

13-7-02-7-0

16-5-152-10-15

22-1-95-7-10

26-6-84-4-15

27-6-141-0-6

28-6-8

0-11-10

31-5-02-10-8

38-6-87-1-8

38-10-80-4-0

40-10-8

2-0-041-2-80-4-0

42-5-0

1-2-8

4-10-154-10-15

11-0-06-1-1

16-5-155-5-15

22-1-95-7-10

27-6-145-5-5

31-5-03-10-2

34-8-23-3-3

38-6-83-10-6

40-10-82-4-0

42-5-01-6-8

0-6-

3

5-1-

3

0-6-

3

1-0-

0

5-1-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-1-2,0-1-8], [4:0-3-0,0-2-4], [6:0-4-0,0-3-0], [8:0-3-0,0-2-4], [10:0-1-0,0-3-8], [10:0-1-12,0-0-0], [11:0-1-4,0-2-1], [11:0-6-10,Edge], [14:0-5-8,0-4-0],[16:0-3-8,Edge], [19:0-4-0,0-3-0], [21:0-2-4,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.600.980.64

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.16

-0.380.07

(loc)121211

l/defl>999>495

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 256 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

8-11: 2x6 SP No.2BOT CHORD 2x4 SP No.2 P *Except*

7-16: 2x4 SP No.3, 10-14: 2x4 SP No.2, 11-12: 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x4 SP No.3 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 5-0-0 oc bracing. Except:

2-2-0 oc bracing: 14-16

REACTIONS. All bearings 25-4-0 except (jt=length) 11=0-8-0, 17=0-4-0, 23=0-3-8, 20=0-3-8.(lb) - Max Horz 22=151(LC 11)

Max Uplift All uplift 100 lb or less at joint(s) 21, 23 except 11=-170(LC 12), 22=-203(LC 12), 19=-248(LC 12), 18=-426(LC 12), 17=-126(LC 12)

Max Grav All reactions 250 lb or less at joint(s) 23, 20 except 11=569(LC 22), 22=558(LC 21), 21=373(LC 21), 19=573(LC 21), 18=1630(LC 22), 17=583(LC 22)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-181/324, 3-25=-82/301, 4-25=-66/453, 4-26=-189/768, 26-27=-189/768,

5-27=-189/768, 5-6=-188/768, 6-28=-64/658, 7-28=-64/658, 9-30=-650/430, 30-31=-759/410, 10-31=-770/409

BOT CHORD 1-23=-212/256, 22-23=-212/256, 21-22=-250/264, 20-21=-362/301, 19-20=-362/301, 18-19=-1318/626, 17-18=-301/125, 16-17=-301/125, 14-16=-444/203, 7-14=-1130/505, 13-14=-710/378, 10-13=-309/752

WEBS 3-22=-465/340, 4-19=-576/280, 5-19=-479/312, 6-19=-169/744, 6-18=-1374/552, 14-18=-1038/511, 6-14=-306/796, 7-13=-379/1048, 9-13=-789/486

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 11-0-0, Exterior(2)11-0-0 to 15-2-15, Interior(1) 15-2-15 to 31-5-0, Exterior(2) 31-5-0 to 35-7-15, Interior(1) 35-7-15 to 42-1-0 zone; cantilever left andright exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Lumber designated with a "P" is pressure-treated with preservatives. Plate lateral resistance values have been reduced 20%

where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borateor other suitable treatment may be used if it does not corrode the plates. If ACQ, CBA, or CA-B treated lumber is used, improvedcorrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not beenconsidered for this design. Building designer to verify suitability of this product for its intended use.Continued on page 2

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 19: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A03

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992381

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:34:26 2020 Page 2 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-oPrrLuHozinyRQTnFc9dcwjW1_dum7H1a1xJQqyotch

NOTES-8) Solid blocking is required on both sides of the truss at joint(s), 11.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 21, 23 except (jt=lb) 11=170, 22=203, 19=248, 18=426

, 17=126.

LOAD CASE(S) Standard

Page 20: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A04

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992382

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:05 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-bWQA_uEVl_HfocDuECzeWMWR78_CjSxWuCJrQ1youHC

Scale = 1:73.2

1

2

3

4 5 6 7 19

8

920

10

18 17 16 1514

1312

11

21

22

23 24 25 26

27

28

5x8 5x6

8x14 MT20HS

5x8

4x6 5x6

5x12

10x14

2x4

3x4

2x4 7x10 8x10

3x4

4x6

5x8

10x16 MT20HS

10x16 MT20HS

7x10

5x6

5x6

5x8

1-2-81-2-8

1-6-8

0-4-0

7-3-45-8-12

13-0-05-8-12

20-3-47-3-4

27-6-87-3-4

33-8-106-2-2

38-6-84-9-14

38-10-80-4-0

40-10-8

2-0-041-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-3-45-8-12

13-0-05-8-12

20-3-47-3-4

27-6-87-3-4

29-5-01-10-8

33-8-104-3-10

38-6-84-9-14

40-10-82-4-0

42-5-01-6-8

0-6-

3

5-11

-3

0-6-

3

1-0-

0

5-11

-3

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-5-0], [4:0-4-0,0-2-2], [6:0-3-0,0-3-0], [7:0-11-0,0-2-4], [9:0-5-0,0-5-0], [9:0-1-12,0-0-0], [10:0-6-10,Edge], [10:0-3-1,0-2-8],[13:0-4-4,0-3-0], [15:0-3-0,0-1-8], [16:0-5-0,0-4-8], [17:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.900.860.81

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.45

-0.870.40

(loc)141110

l/defl>999>573

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 354 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.1 *Except*

4-6: 2x4 SP M 31, 7-10: 2x6 SP M 26, 6-7: 2x4 SP No.2BOT CHORD 2x6 SP No.2 *Except*

6-15: 2x4 SP No.3, 9-13: 2x4 SP M 31WEBS 2x4 SP No.3 *Except*

13-16: 2x4 SP No.2OTHERS 2x6 SP M 26LBR SCAB 7-10 2x6 SP M 26 both sidesSLIDER Left 2x8 SP 2400F 2.0E 3-6-5

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 5-7-7 oc bracing. Except:

10-0-0 oc bracing: 13-15WEBS 1 Row at midpt 13-16

REACTIONS. (size) 10=0-8-0, 1=0-8-0Max Horz 1=176(LC 11)Max Uplift 10=-600(LC 12), 1=-613(LC 12)Max Grav 10=2119(LC 1), 1=2097(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4333/1681, 3-4=-3756/1554, 4-5=-4017/1727, 5-6=-4338/1821, 6-7=-4372/1829,

7-8=-5930/2416, 8-9=-5571/2117, 9-10=-738/323BOT CHORD 1-18=-1441/3869, 17-18=-1441/3869, 16-17=-1173/3384, 15-16=-148/453, 6-13=-349/273,

12-13=-1375/4041, 9-12=-1918/5349WEBS 3-17=-574/306, 4-17=-91/508, 4-16=-331/933, 5-16=-895/476, 13-16=-1249/3593,

5-13=-113/454, 7-13=-339/924, 7-12=-793/1912, 8-12=-1324/685

NOTES-1) Attached 14-3-5 scab 7 to 10, both face(s) 2x6 SP M 26 with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at

9-6-12 from end at joint 7, nail 3 row(s) at 4" o.c. for 4-2-12.2) Unbalanced roof live loads have been considered for this design.3) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 13-0-6, Exterior(2) 13-0-6 to17-3-4, Interior(1) 17-3-4 to 29-5-0, Exterior(2) 29-5-0 to 33-8-10, Interior(1) 33-8-10 to 42-1-0 zone; cantilever left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

4) Provide adequate drainage to prevent water ponding.5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.8) Solid blocking is required on both sides of the truss at joint(s), 10.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

10=600, 1=613.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 21: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A05

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992383

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:06 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-3i_ZCDF7WIPWQmo4ovUt3a3bNXKhSvig7s2OyTyouHB

Scale = 1:78.0

1

2

3

4 5 6

78

22

923

10

18 17 16 1514

1312

11

24

25

26 27 28 29

30

31

6x12 MT20HS

5x8 WB

7x10 4x6

10x12

10x16 MT20HS

4x6

5x6

2x4 6x8

5x6 3x4

2x4

2x4

5x12

10x16 MT20HS

2x4

10x12

2x4

2x4 7x10

5x6 5x6

5x8

1-2-81-2-8

1-6-8

0-4-0

8-6-26-11-10

15-0-06-5-14

21-2-86-2-8

27-5-06-2-8

30-2-02-9-0

34-2-134-0-13

34-10-130-8-0

36-11-0

2-0-337-11-0

1-0-040-10-82-11-8

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

8-6-26-11-10

15-0-06-5-14

21-2-86-2-8

27-5-06-2-8

34-2-136-9-13

34-10-130-8-0

40-10-85-11-11

42-5-01-6-8

0-6-

3

6-9-

3

0-6-

3

1-0-

0

6-9-

3

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-5-0], [3:0-3-0,0-3-0], [4:0-3-0,0-2-4], [7:0-4-0,Edge], [8:0-3-12,0-2-8], [9:0-10-0,0-0-8], [10:0-6-10,Edge], [10:0-3-4,Edge],[13:0-6-0,Edge], [16:0-1-12,0-3-0], [17:0-4-12,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.990.840.78

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.44-1.210.33

(loc)111110

l/defl>999>415

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 347 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

3-4: 2x4 SP No.1, 6-7: 2x4 SP M 31, 7-10,8-10: 2x6 SP M 26BOT CHORD 2x6 SP No.2 *Except*

6-15: 2x4 SP No.3, 9-13: 2x6 SP M 26WEBS 2x4 SP No.3 *Except*

13-16: 2x4 SP No.2OTHERS 2x6 SP M 26 *Except*

7-7: 2x4 SP No.3LBR SCAB 7-10 2x6 SP M 26 both sidesSLIDER Left 2x8 SP 2400F 2.0E 4-2-6

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 6-3-12 oc bracing. Except:

10-0-0 oc bracing: 13-15WEBS 1 Row at midpt 8-13

REACTIONS. (size) 10=0-8-0, 1=0-8-0Max Horz 1=-202(LC 10)Max Uplift 10=-572(LC 12), 1=-605(LC 12)Max Grav 10=2164(LC 1), 1=2110(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4322/1617, 3-4=-3568/1452, 4-5=-3525/1516, 5-6=-3804/1557, 6-8=-4259/1609,

8-9=-6097/2213, 9-10=-746/321BOT CHORD 1-18=-1369/3853, 17-18=-1371/3850, 16-17=-1038/3195, 15-16=-153/340, 13-15=0/270,

6-13=-301/1124, 12-13=-2076/5990, 9-12=-2079/5993WEBS 3-18=0/290, 3-17=-780/385, 4-17=-131/601, 4-16=-197/626, 5-16=-847/391,

13-16=-997/3226, 5-13=-54/447, 8-13=-2258/941

NOTES-1) Attached 9-1-1 scab 7 to 10, both face(s) 2x6 SP M 26 with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 4-5-5

from end at joint 7, nail 2 row(s) at 7" o.c. for 2-0-0; starting at 6-8-7 from end at joint 7, nail 3 row(s) at 7" o.c. for 2-0-0.2) Unbalanced roof live loads have been considered for this design.3) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 15-0-0, Exterior(2) 15-0-0 to19-2-15, Interior(1) 19-2-15 to 27-4-10, Exterior(2) 27-4-10 to 31-7-9, Interior(1) 31-7-9 to 42-1-0 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

4) Provide adequate drainage to prevent water ponding.5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.8) Solid blocking is required on both sides of the truss at joint(s), 10.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

10=572, 1=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 22: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A06

Truss Type

HIP

Qty

1

Ply

1

Job Reference (optional)

T20992384

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:08 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-?45JdvGO1vfEf3yTvKXL8?8zFL2YwpazaAXV1MyouH9

Scale = 1:73.0

1

2

3

4

5 6 7

8

9

10

11

17 1615 14

13 12

18 19

20 21

5x8 WB4x6

5x6

3x4

3x8

3x4

3x8

3x4

4x6

5x6

5x8 WB7x10

5x8

7x10

5x8

1-2-81-2-8

1-6-8

0-4-0

9-1-137-7-6

17-0-07-10-3

25-5-08-5-0

33-3-27-10-3

40-10-87-7-5

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

6-1-24-6-10

12-0-35-11-1

17-0-04-11-13

21-2-84-2-8

25-5-04-2-8

30-4-134-11-13

36-3-145-11-1

40-10-84-6-10

42-5-01-6-8

0-6-

3

7-7-

3

0-6-

3

7-7-

3

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-5-0], [3:0-3-0,0-3-0], [5:0-3-0,0-2-4], [7:0-3-0,0-2-4], [9:0-3-0,0-3-0], [11:0-4-7,0-5-0], [11:Edge,0-4-5]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.840.750.82

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.28-0.650.17

(loc)14-1514-15

11

l/defl>999>772

n/a

L/d240180n/a

PLATESMT20

Weight: 268 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2 *Except*

13-16: 2x4 SP No.1WEBS 2x4 SP No.3OTHERS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-0-0, Right 2x8 SP 2400F 2.0E 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-1-10 oc purlins.BOT CHORD Rigid ceiling directly applied or 5-8-11 oc bracing.WEBS 1 Row at midpt 6-15, 6-14

REACTIONS. (size) 1=0-8-0, 11=0-8-0Max Horz 1=229(LC 11)Max Uplift 1=-618(LC 12), 11=-618(LC 12)Max Grav 1=2088(LC 1), 11=2088(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4332/1668, 3-4=-4015/1574, 4-5=-3202/1397, 5-6=-2889/1356, 6-7=-2889/1356,

7-8=-3202/1397, 8-9=-4015/1574, 9-11=-4332/1668BOT CHORD 1-17=-1422/3864, 15-17=-1209/3423, 14-15=-971/2987, 12-14=-1203/3423,

11-12=-1417/3864WEBS 3-17=-328/281, 4-17=-84/488, 4-15=-793/421, 5-15=-317/877, 6-15=-363/170,

6-14=-363/170, 7-14=-317/877, 8-14=-793/421, 8-12=-84/488, 9-12=-328/281

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 17-0-0, Exterior(2) 17-0-0 to21-2-8, Interior(1) 21-2-8 to 25-5-0, Exterior(2) 25-5-0 to 29-7-15, Interior(1) 29-7-15 to 42-1-0 zone; cantilever left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are 5x6 MT20 unless otherwise indicated.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=618, 11=618.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 23: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A07

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992385

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:09 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-THfhqFH0oDn5HDWfT22agChATlMefF46pqH2ZoyouH8

Scale = 1:74.2

1

2

3

4

5 6

7

8

910

11

12

23 2221

2019 18

17

1615 14 13

24

25

26

27

6x12 MT20HS

5x8 5x6

5x8

5x6

3x4

6x8

7x10

3x4

3x4

7x10 2x4

3x6

4x6

2x4

7x10 3x8 7x10

5x6

5x6

5x8

7x10

4x6

4x6

4x6 13-7-0 10-10-0 15-7-0

1-2-81-2-8

1-6-8

0-4-0

7-3-55-8-13

13-9-86-6-3

14-9-81-0-0

19-0-04-2-8

23-5-04-5-0

25-7-82-2-8

29-11-54-3-13

31-6-81-7-3

34-4-92-10-1

35-0-90-8-0

35-4-9

0-4-0

36-6-8

1-1-1536-10-8

0-4-0

40-10-84-0-0

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-3-55-8-13

13-9-86-6-3

19-0-05-2-8

23-5-04-5-0

26-7-83-2-8

29-11-53-3-13

34-4-94-5-4

35-0-90-8-0

35-4-9

0-4-0

40-10-85-5-15

42-5-01-6-8

0-6-

3

8-5-

3

0-6-

3

1-0-

0

8-5-

3

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-5-0], [5:0-5-12,0-2-8], [6:0-3-0,0-2-4], [9:0-4-0,Edge], [12:1-6-14,Edge], [12:0-2-2,0-5-0], [14:0-4-0,0-4-8], [17:0-6-0,0-5-4],[20:0-6-4,Edge], [22:0-3-0,0-1-8], [23:0-3-8,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.750.820.87

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.31

-0.610.25

(loc)21

19-2012

l/defl>999>815

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 311 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

1-4: 2x4 SP No.1, 9-12: 2x6 SP No.2BOT CHORD 2x6 SP No.2 *Except*

4-22: 2x4 SP No.3, 17-20: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

20-23,14-17: 2x4 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-6-5, Right 2x6 SP No.2 3-1-15

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 5-5-6 oc bracing. Except:

10-0-0 oc bracing: 20-22WEBS 1 Row at midpt 4-19, 5-18, 7-18

REACTIONS. (size) 1=0-8-0, 12=0-8-0Max Horz 1=-302(LC 10)Max Uplift 1=-604(LC 12), 12=-605(LC 12)Max Grav 1=2112(LC 1), 12=2109(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4363/1620, 3-4=-4380/1718, 4-5=-3420/1462, 5-6=-3083/1417, 6-7=-3367/1477,

7-8=-4077/1683, 8-10=-3823/1530, 10-12=-4456/1655BOT CHORD 1-23=-1362/3904, 22-23=-156/425, 4-20=-144/695, 19-20=-1344/3965, 18-19=-932/3088,

17-18=-1210/3726, 13-14=-1397/3993, 12-13=-1397/3993WEBS 3-23=-452/291, 20-23=-1218/3519, 4-19=-1282/567, 6-18=-356/960, 8-14=-782/311,

7-17=-356/1113, 5-19=-322/982, 10-14=-689/324, 8-17=-75/501, 14-17=-1210/3604, 7-18=-1283/572

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=79ft; L=40ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 4-4-0, Interior(1) 4-4-0 to 19-0-0, Exterior(2) 19-0-0 to29-0-14, Interior(1) 29-0-14 to 42-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=604, 12=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 24: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A08

Truss Type

ROOF SPECIAL

Qty

1

Ply

1

Job Reference (optional)

T20992386

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:10 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-xTD32bIeZXvyvN5r1lZpDQEHc9gzOi2G2U0c5FyouH7

Scale = 1:74.7

1

2

3

4

5

6

7

8

9

10

19 1817

1615

14

1312 11

20

21 22

5x6

5x6

3x6

4x6

5x6

4x6

4x6 8x10 6x8

6x12 MT20HS

5x8 7x10

3x4

8x10

5x6

5x6

5x8

7x10

5x6

5x6

5x8

13-0-0 12-0-0

1-2-81-2-8

1-6-8

0-4-0

7-3-45-8-12

13-2-85-11-4

14-2-81-0-0

21-2-87-0-0

26-2-85-0-0

27-2-81-0-0

34-0-86-10-0

40-10-86-10-0

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-3-45-8-12

13-2-85-11-4

21-2-88-0-0

27-2-86-0-0

34-0-86-10-0

40-10-86-10-0

42-5-01-6-8

0-6-

3

9-3-

3

0-6-

3

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-4-0], [3:0-3-0,0-3-0], [10:Edge,0-4-5], [10:0-4-7,0-5-0], [11:0-5-0,0-4-8], [12:0-3-0,0-0-0], [14:0-6-4,Edge], [16:0-7-12,0-3-4],[18:0-3-0,0-0-8], [19:0-3-8,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.980.950.88

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.33

-0.690.27

(loc)13

15-1610

l/defl>999>721

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 283 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

3-5: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

4-18,6-12: 2x4 SP No.3, 14-16: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

16-19,11-14: 2x4 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-6-5, Right 2x8 SP 2400F 2.0E 4-1-8

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 5-7-14 oc bracing. Except:

10-0-0 oc bracing: 16-18, 12-14WEBS 1 Row at midpt 4-15, 6-15

REACTIONS. (size) 1=0-8-0, 10=0-8-0Max Horz 1=337(LC 11)Max Uplift 1=-604(LC 12), 10=-605(LC 12)Max Grav 1=2112(LC 1), 10=2109(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4344/1504, 3-4=-4501/1589, 4-5=-3160/1222, 5-6=-3122/1237, 6-8=-4241/1515,

8-10=-4319/1498BOT CHORD 1-19=-1235/3890, 18-19=-176/399, 4-16=-124/737, 15-16=-1220/4144, 14-15=-1099/3841,

6-14=-196/835, 11-12=-102/317, 10-11=-1212/3851WEBS 3-19=-505/264, 16-19=-1086/3550, 3-16=0/264, 4-15=-1656/649, 5-15=-576/1800,

6-15=-1463/583, 11-14=-1122/3562, 8-11=-472/284

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=79ft; L=40ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 4-4-0, Interior(1) 4-4-0 to 21-2-8, Exterior(2) 21-2-8 to25-2-8, Interior(1) 25-2-8 to 42-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=604, 10=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 25: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A10

Truss Type

Roof Special

Qty

6

Ply

1

Job Reference (optional)

T20992387

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:11 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QfnSFxIGKq1pWXg2aS42mdmSMY0C79mPG8m9ehyouH6

Scale = 1:72.2

1

2

3

4

5

6

7

8

9

10

19 1817

1615

14

1312 11

20

21 22

23

5x6

5x6

3x6

4x6

5x6

4x6

4x6 8x10 6x8

6x12 MT20HS

5x8 7x10

3x4

8x10

5x6

5x6

5x8

8x10

5x6

5x6

5x8

1-2-81-2-8

1-6-8

0-4-0

7-3-45-8-12

13-2-85-11-4

14-2-81-0-0

21-2-87-0-0

26-2-85-0-0

27-2-81-0-0

34-0-86-10-0

40-10-86-10-0

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-3-45-8-12

13-2-85-11-4

21-2-88-0-0

27-2-86-0-0

34-0-86-10-0

40-10-86-10-0

42-5-01-6-8

0-6-

3

9-4-

4

0-6-

3

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-4-0], [3:0-3-0,0-3-0], [10:Edge,0-4-5], [10:0-4-7,0-4-0], [11:0-5-0,0-4-8], [12:0-3-0,0-0-0], [14:0-6-4,Edge], [16:0-7-12,0-3-4],[18:0-3-0,0-0-8], [19:0-3-8,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.980.950.85

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.33

-0.690.27

(loc)13

15-1610

l/defl>999>721

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 283 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

3-5: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

4-18,6-12: 2x4 SP No.3, 14-16: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

16-19,11-14: 2x4 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-6-5, Right 2x8 SP 2400F 2.0E 4-1-8

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 5-9-1 oc bracing. Except:

10-0-0 oc bracing: 16-18, 12-14WEBS 1 Row at midpt 4-15, 6-15

REACTIONS. (size) 1=0-8-0, 10=0-8-0Max Horz 1=-284(LC 10)Max Uplift 1=-604(LC 12), 10=-605(LC 12)Max Grav 1=2112(LC 1), 10=2109(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-4344/1449, 3-4=-4501/1543, 4-5=-3160/1185, 5-6=-3122/1200, 6-8=-4241/1471,

8-10=-4319/1446BOT CHORD 1-19=-1189/3873, 18-19=-170/397, 4-16=-112/737, 15-16=-1178/4144, 14-15=-1057/3841,

6-14=-185/833, 11-12=-97/317, 10-11=-1172/3851WEBS 3-19=-505/260, 16-19=-1044/3535, 3-16=0/264, 4-15=-1578/629, 5-15=-558/1800,

6-15=-1407/561, 11-14=-1084/3562, 8-11=-472/279

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 21-2-8, Exterior(2) 21-2-8 to24-2-8, Interior(1) 24-2-8 to 42-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=604, 10=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 26: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A11

Truss Type

COMMON

Qty

1

Ply

1

Job Reference (optional)

T20992388

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:12 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-usLqSHJu589g8hFE8AbHIrJeSyObscrYVoViA7youH5

Scale = 1:69.2

1

2

3

4

5

6

7

8

9

14 1312

11 10

15

16 17

18 19 20 21

5x6

7x10

5x6

5x6

5x8 WB3x8

3x4

4x6

5x6

3x4

4x6

5x6

5x8 WB7x10

5x6

5x6

5x8

1-2-81-2-8

1-6-8

0-4-0

11-4-89-10-0

21-2-89-10-0

31-0-89-10-0

40-10-89-10-0

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-11-76-4-15

14-9-156-10-8

21-2-86-4-9

27-7-16-4-9

34-5-96-10-8

40-10-86-4-15

42-5-01-6-8

1-0-

4

9-4-

4

0-6-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-8-3,0-0-6], [3:0-3-0,0-3-0], [7:0-3-0,0-3-0], [9:0-4-7,0-5-0], [9:Edge,0-4-5]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.960.810.86

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.25-0.570.15

(loc)12-1412-14

9

l/defl>999>864

n/a

L/d240180n/a

PLATESMT20

Weight: 251 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.1 *Except*

1-3: 2x4 SP M 31, 7-9: 2x4 SP No.2BOT CHORD 2x6 SP No.2 *Except*

11-13: 2x4 SP No.1WEBS 2x4 SP No.3OTHERS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-4-3, Right 2x8 SP 2400F 2.0E 3-10-12

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 6-5-11 oc bracing.WEBS 1 Row at midpt 6-12, 4-12

REACTIONS. (size) 1=0-8-0, 9=0-8-0Max Horz 1=337(LC 11)Max Uplift 1=-605(LC 12), 9=-605(LC 12)Max Grav 1=2063(LC 17), 9=2070(LC 18)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-3854/1419, 3-4=-3527/1338, 4-5=-2639/1140, 5-6=-2636/1137, 6-7=-3797/1409,

7-9=-4190/1525BOT CHORD 1-14=-1125/3579, 12-14=-891/3142, 10-12=-926/3054, 9-10=-1245/3725WEBS 5-12=-549/1547, 6-12=-1154/503, 6-10=-156/769, 7-10=-517/381, 4-12=-1031/464,

4-14=-79/523, 3-14=-268/292

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=79ft; L=40ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 5-2-8, Interior(1) 5-2-8 to 21-2-8, Exterior(2) 21-2-8 to25-2-8, Interior(1) 25-2-8 to 42-1-0 zone; cantilever right exposed ;C-C for members and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60

3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=605, 9=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 27: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A12

Truss Type

Roof Special

Qty

4

Ply

1

Job Reference (optional)

T20992389

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:14 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-qETatzL8dlPOO_PdGbelNGOzYm1dKVBry6_pE0youH3

Scale = 1:73.6

1 21

2

3

22

4

5

6

7

8

9

10

18

1716

1514 13 12 11

23

24 25

26

5x8

5x6

5x6

5x8

4x6 2x4

10x14 8x12

7x10

6x8

10x16 MT20HS

2x4

3x4

7x10 2x4

2x4

2x4

4x12

6x8

7x10

5x6

5x6

5x8

1-2-81-2-8

1-6-8

0-4-0

3-6-82-0-0

3-10-80-4-0

7-3-33-4-11

11-2-83-11-5

13-8-82-6-0

14-8-81-0-0

16-7-41-10-12

19-6-82-11-4

21-2-81-8-0

28-1-56-10-13

34-7-66-6-1

40-10-86-3-2

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

3-10-82-4-0

7-3-33-4-11

13-8-86-5-5

16-7-42-10-12

21-2-84-7-4

28-1-56-10-13

34-7-66-6-1

40-10-86-3-2

42-5-01-6-8

0-6-

3

9-4-

4

0-6-

3

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:0-3-1,0-2-8], [1:0-6-10,Edge], [2:0-1-12,0-0-0], [2:0-5-0,0-5-0], [3:0-1-0,0-2-4], [8:0-3-0,0-3-0], [10:0-4-7,0-5-0], [10:Edge,0-4-5], [12:0-3-12,0-4-8],[13:0-4-12,0-4-8], [14:0-3-8,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.980.960.94

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.42-1.140.37

(loc)151510

l/defl>999>438

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 352 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

4-6: 2x6 SP No.2, 1-4: 2x6 SP M 26, 1-3: 2x4 SP No.1BOT CHORD 2x6 SP No.2 *Except*

2-16: 2x4 SP M 31, 6-13: 2x4 SP No.3WEBS 2x4 SP No.3 *Except*

14-16: 2x4 SP No.2OTHERS 2x6 SP M 26LBR SCAB 1-4 2x6 SP M 26 both sidesSLIDER Right 2x8 SP 2400F 2.0E 3-9-12

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except:

7-1-0 oc bracing: 6-13WEBS 1 Row at midpt 7-13, 5-13

REACTIONS. (size) 1=0-8-0, 10=0-8-0Max Horz 1=335(LC 11)Max Uplift 1=-604(LC 12), 10=-616(LC 12)Max Grav 1=2111(LC 1), 10=2091(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-860/310, 2-3=-6073/2159, 3-5=-4764/1726, 5-6=-2757/1209, 6-7=-2798/1185,

7-8=-3621/1371, 8-10=-4305/1527BOT CHORD 2-17=-1993/6052, 16-17=-1991/6049, 6-13=-648/1678, 13-14=-862/3087,

12-13=-973/3261, 11-12=-1247/3835, 10-11=-1245/3838WEBS 7-13=-1191/466, 7-12=-69/550, 8-12=-714/339, 8-11=0/261, 5-14=-362/291,

14-16=-877/3141, 5-16=-644/1906, 3-16=-1971/824, 5-13=-1210/453

NOTES-1) Attached 9-0-0 scab 1 to 4, both face(s) 2x6 SP M 26 with 2 row(s) of 10d (0.131"x3") nails spaced 9" o.c.except : starting at 0-3-8

from end at joint 1, nail 3 row(s) at 4" o.c. for 5-4-1.2) Unbalanced roof live loads have been considered for this design.3) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=79ft; L=40ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 4-4-0, Interior(1) 4-4-0 to 21-2-8, Exterior(2) 21-2-8 to25-2-8, Interior(1) 25-2-8 to 42-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.7) Solid blocking is required on both sides of the truss at joint(s), 1.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=604, 10=616.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 28: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A13

Truss Type

ROOF SPECIAL

Qty

6

Ply

1

Job Reference (optional)

T20992390

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:15 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-IR0y5ILnO3XF?8_ppI9_wTx9vAOR3xp?BmkNnSyouH2

Scale = 1:72.2

6

7

8

9

10

111

2

3

4

5

1413 12

16 15

20 19 1817

21

22

23

4x6 3x6

4x6

5x6

6x8

6x12 MT20HS5x12

3x4

8x10

5x6

2x4 2x4

8x10 5x8

8x10

5x8

21-8-8

21-8-8

20-6-0

21-8-0 4-10-0

1-2-81-2-8

1-6-8

0-4-0

7-9-106-3-2

14-3-116-6-1

21-2-86-10-13

22-4-81-2-0

22-10-8

0-6-0

28-0-105-2-2

28-8-80-7-14

35-0-146-4-6

40-10-85-9-10

41-2-80-4-0

42-5-0

1-2-8

1-6-81-6-8

7-9-106-3-2

14-3-116-6-1

21-2-86-10-13

28-8-87-6-0

35-0-146-4-6

40-10-85-9-10

42-5-01-6-8

0-6-

3

9-4-

4

0-6-

3

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:Edge,0-4-5], [1:0-4-7,0-4-0], [3:0-3-0,0-3-0], [7:0-3-0,Edge], [9:0-3-0,0-3-0], [11:Edge,0-4-5], [11:0-4-7,0-4-0], [12:0-3-8,0-3-0], [13:0-3-0,0-0-0],[15:0-8-0,0-3-0], [16:0-5-4,0-3-0], [19:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.940.930.98

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.30

-0.71-0.23

(loc)14

15-161

l/defl>999>702

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 292 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP M 31 *Except*

3-5,9-11,1-3: 2x4 SP No.2BOT CHORD 2x6 SP No.2 *Except*

8-13: 2x4 SP No.3, 15-16: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

12-15,16-19: 2x4 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-9-12, Right 2x8 SP 2400F 2.0E 3-6-13

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. Except:

10-0-0 oc bracing: 13-15WEBS 1 Row at midpt 8-16, 4-16

REACTIONS. (size) 11=0-8-0, 1=0-8-0Max Horz 11=337(LC 11)Max Uplift 11=-600(LC 12), 1=-605(LC 12)Max Grav 11=2119(LC 1), 1=2110(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 6-8=-3171/1227, 8-9=-4435/1544, 9-11=-4364/1494, 1-3=-4350/1502, 3-4=-3663/1342,

4-6=-3112/1216BOT CHORD 12-13=-173/382, 11-12=-1227/3911, 8-15=-117/772, 15-16=-1162/4063, 1-20=-1223/3880,

19-20=-1225/3877WEBS 9-12=-466/256, 12-15=-1078/3579, 8-16=-1587/600, 4-16=-791/364, 3-19=-732/347,

3-20=0/261, 16-19=-942/3244, 6-16=-555/1786

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=79ft; L=40ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 4-4-0, Interior(1) 4-4-0 to 21-2-8, Exterior(2) 21-2-8 to25-2-8, Interior(1) 25-2-8 to 42-1-0 zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) All plates are MT20 plates unless otherwise indicated. 4) All plates are 5x6 MT20 unless otherwise indicated.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

11=600, 1=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 29: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A14

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992391

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:16 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-mdaLIeMP9Nf5dIZ?N0gDThTJEZlXoQF8QQTwJuyouH1

Scale = 1:71.8

1

2

3

4

5

6

7

8

9

10

1615 14

1312 11

17 18

19

20 21 22 23

5x6

7x10

4x6

4x6

5x8 WB3x8

3x4

4x6

5x6

3x4

4x6

5x6

5x8 WB4x6

2x4

8x10

5x6

5x6

5x6

0-4-00-4-0

4-10-84-6-8

6-8-151-10-7

10-2-03-5-1

20-0-09-10-0

29-10-09-10-0

39-8-09-10-0

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

4-10-84-6-8

6-8-151-10-7

13-7-76-10-8

20-0-06-4-9

26-4-96-4-9

33-3-16-10-8

39-8-06-4-15

41-2-81-6-8

1-0-

4

9-3-

10

0-6-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [4:0-3-0,0-3-0], [8:0-3-0,0-3-0], [10:0-4-7,0-4-0], [10:1-8-1,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.970.810.84

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.24-0.530.15

(loc)11-1311-13

10

l/defl>999>933

n/a

L/d240180n/a

PLATESMT20

Weight: 257 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

1-4: 2x4 SP No.1BOT CHORD 2x6 SP No.2 *Except*

12-14: 2x4 SP No.1WEBS 2x4 SP No.3OTHERS 2x4 SP No.3SLIDER Left 2x6 SP No.2 3-4-3, Right 2x8 SP 2400F 2.0E 3-10-12

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 6-7-5 oc bracing.WEBS 1 Row at midpt 7-13, 5-13

REACTIONS. (size) 1=Mechanical, 10=0-8-0Max Horz 1=-284(LC 10)Max Uplift 1=-605(LC 12), 10=-605(LC 12)Max Grav 1=2044(LC 1), 10=2044(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-3705/1316, 3-4=-3615/1340, 4-5=-3547/1308, 5-6=-2636/1105, 6-7=-2637/1104,

7-8=-3745/1369, 8-10=-4150/1480BOT CHORD 1-16=-1038/3271, 15-16=-1076/3509, 13-15=-861/3039, 11-13=-892/3053,

10-11=-1209/3703WEBS 6-13=-532/1534, 7-13=-1096/488, 7-11=-148/743, 8-11=-491/370, 5-13=-971/452,

5-15=-85/569, 4-15=-349/252, 4-16=-352/112, 3-16=-88/429

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 21-2-8, Exterior(2) 21-2-8 to24-2-8, Interior(1) 24-2-8 to 42-1-0 zone; cantilever right exposed ;C-C for members and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60

3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=605, 10=605.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 30: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A15

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992392

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:17 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-Ep8jW_N1wgnyFS8CxjBS?u0V5z3KXteHf4DTrLyouH0

Scale = 1:81.4

7

8

9

10

11

5 6

12

3

4

14 13 12

17 16 15

22 21 20 19 18

24

25

26

5x6

5x6 5x8

5x6

2x4 2x4

2x4 7x10

7x10

5x8

7x10

8x10

3x4

2x4 6x8

3x4

2x4

5x8

2x4

3x4

2x4 5x12

8x10

5x6

5x6

5x8

5-1-135-1-13

11-6-36-4-5

17-10-86-4-5

21-8-03-9-8

22-1-80-5-8

26-6-04-4-8

28-5-131-11-13

34-10-36-4-5

40-0-05-1-13

41-2-81-2-8

5-1-135-1-13

11-6-36-4-5

17-10-86-4-5

21-8-03-9-8

22-1-80-5-8

26-6-04-4-8

28-5-131-11-13

34-10-36-4-5

41-2-86-4-5

1-0-

4

8-5-

10

0-6-

3

1-0-

0

8-5-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [3:0-3-0,0-3-0], [5:0-5-12,0-2-8], [7:0-3-0,0-2-4], [9:0-3-0,0-3-0], [11:0-4-7,0-4-0], [11:Edge,0-4-5], [12:0-3-8,0-3-8], [15:0-3-8,0-2-4],[17:0-7-0,0-2-8], [20:0-1-12,0-3-0], [21:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.900.900.89

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.31

-0.60-0.23

(loc)14

15-161

l/defl>999>812

n/a

L/d240180n/a

PLATESMT20

Weight: 311 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.1 *Except*

5-7,9-11: 2x4 SP No.2, 1-3: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

14-23,16-18: 2x4 SP No.3, 15-17: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

12-15,17-20: 2x4 SP No.2SLIDER Left 2x6 SP No.2 2-5-13, Right 2x8 SP 2400F 2.0E 3-0-6

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 5-5-5 oc bracing.WEBS 1 Row at midpt 8-16, 6-19, 4-20

REACTIONS. (size) 1=Mechanical, 11=0-8-0Max Horz 11=-256(LC 10)Max Uplift 1=-593(LC 12), 11=-584(LC 12)Max Grav 1=2065(LC 1), 11=2080(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 7-8=-3326/1338, 8-9=-4646/1692, 9-11=-4322/1518, 5-6=-2963/1311, 6-7=-2986/1319,

1-3=-3759/1372, 3-4=-3562/1378, 4-5=-2930/1240BOT CHORD 11-12=-1261/3857, 16-17=-819/2967, 15-16=-1335/4240, 1-22=-1090/3263,

21-22=-1093/3265, 20-21=-1042/3241WEBS 9-12=-567/306, 9-15=-55/393, 8-15=-157/854, 5-20=-289/52, 4-21=0/307,

7-16=-263/824, 8-16=-1548/622, 12-15=-1254/3825, 6-17=-265/86, 4-20=-870/407, 6-16=-112/251, 5-17=-307/1026, 17-20=-760/2690

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 19-1-0, Exterior(2) 19-1-0 to27-6-15, Interior(1) 27-6-15 to 42-1-0 zone; cantilever right exposed ;C-C for members and forces & MWFRS for reactions shown;Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Refer to girder(s) for truss to truss connections.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=593, 11=584.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 31: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A16

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992393

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:19 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-BCGTwgPHSI1gUlHa28Dw4J5rmnnT?mqa6NiawDyouH_

Scale = 1:72.6

7

8

9

10

11

5 6

1

2

3

4

14 13 12

1716

15

21 20 19 18

24

25

26

27

28

5x6

5x8 5x8

5x8

7x10

4x6

4x6

6x8

7x10

7x10 4x6

3x4

7x10 3x4 8x10

5x6

5x6

5x8

4-10-0

0-4-00-4-0

8-1-47-9-4

15-10-87-9-4

18-3-102-5-2

19-8-01-4-6

20-8-0

1-0-021-8-0

1-0-0

24-0-132-4-13

24-1-8

0-0-11

26-6-02-4-8

27-6-01-0-0

28-6-0

1-0-0

33-7-05-1-0

39-8-06-1-0

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

5-9-145-5-14

8-1-42-3-6

15-10-87-9-4

18-3-102-5-2

19-8-01-4-6

20-8-0

1-0-024-1-83-5-8

27-6-03-4-8

28-6-01-0-0

33-7-05-1-0

39-8-06-1-0

41-2-81-6-8

1-0-

4

7-7-

10

0-6-

3

1-0-

0

7-7-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [4:0-4-0,0-3-0], [5:0-4-0,0-2-2], [7:0-4-0,0-2-2], [9:0-3-0,0-3-0], [11:Edge,0-4-5], [11:0-4-7,0-4-0], [12:0-3-8,0-3-0], [15:0-3-12,Edge],[17:0-6-4,0-4-12], [20:0-4-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.950.790.85

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.28

-0.55-0.22

(loc)1414

1

l/defl>999>885

n/a

L/d240180n/a

PLATESMT20

Weight: 303 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

4-5,9-11: 2x4 SP M 31, 1-4: 2x4 SP No.1BOT CHORD 2x6 SP No.2 *Except*

15-17: 2x4 SP No.2WEBS 2x4 SP No.3 *Except*

12-15,17-20: 2x4 SP No.2SLIDER Left 2x6 SP No.2 4-1-0, Right 2x8 SP 2400F 2.0E 3-8-10

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 5-10-0 oc bracing.WEBS 1 Row at midpt 4-20

REACTIONS. (size) 1=Mechanical, 11=0-8-0Max Horz 11=230(LC 11)Max Uplift 1=-592(LC 12), 11=-583(LC 12)Max Grav 1=2066(LC 1), 11=2081(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 7-8=-4461/1815, 8-9=-4448/1675, 9-11=-4275/1516, 5-6=-3466/1477, 6-7=-3282/1414,

1-3=-3802/1405, 3-4=-3685/1425, 4-5=-3188/1294BOT CHORD 11-12=-1268/3810, 16-17=-1038/3480, 15-16=-970/3280, 1-21=-1121/3273,

20-21=-1172/3456WEBS 9-12=-568/304, 12-15=-1266/3759, 9-15=-19/331, 7-15=-563/1354, 4-20=-762/371,

8-15=-403/315, 5-17=-355/1110, 7-16=-68/434, 6-16=-549/202, 17-20=-851/2848, 3-21=-78/294

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 17-1-6, Exterior(2) 17-1-6 to21-4-4, Interior(1) 21-4-4 to 25-3-10, Exterior(2) 25-3-10 to 29-6-9, Interior(1) 29-6-9 to 42-1-0 zone; cantilever right exposed ;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are 2x4 MT20 unless otherwise indicated.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=592, 11=583.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 32: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A17

Truss Type

Roof Special

Qty

1

Ply

1

Job Reference (optional)

T20992394

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:20 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-fOqr80PvDb9X6vsmcrl9dXe?_B7kkE1kL1R8RgyouGz

Scale = 1:73.9

78

9

10

11

12

4 5 6

1

2

3

1514 13

17 16

21 20 1918

22

23

24 25

26

5x6

3x6 5x8

5x8

5x6

5x6

2x4

2x4

4x6

7x10

4x6

4x6

6x8

6x8

7x10 2x4

5x6

5x8

8x10

5x6

5x6

5x8

17-1-8

4-10-0

0-4-00-4-0

6-7-36-3-2

13-10-87-3-5

20-8-06-9-8

21-8-01-0-0

26-6-04-10-0

27-6-01-0-0

33-10-66-4-6

39-8-05-9-10

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

6-7-36-3-2

13-10-87-3-5

20-8-06-9-8

26-0-135-4-13

27-6-01-5-3

33-10-66-4-6

39-8-05-9-10

41-2-81-6-8

1-0-

4

6-9-

10

7-7-

13

0-6-

3

1-0-

0

6-9-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [3:0-3-0,0-3-0], [4:0-4-0,0-2-2], [7:0-3-0,Edge], [8:0-2-0,0-2-0], [10:0-3-0,0-3-0], [12:0-4-7,0-4-0], [12:Edge,0-4-5], [13:0-3-8,0-3-0],[14:0-3-0,0-0-0], [16:0-2-4,Edge], [17:0-2-8,0-3-4], [19:0-3-0,0-0-8], [20:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.990.790.79

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.32

-0.68-0.21

(loc)16-1716-17

1

l/defl>999>726

n/a

L/d240180n/a

PLATESMT20

Weight: 291 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

4-8: 2x4 SP No.1, 3-4,1-3: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

9-14,5-19: 2x4 SP No.3, 16-17: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

13-16,17-20: 2x4 SP No.2SLIDER Left 2x6 SP No.2 3-6-0, Right 2x8 SP 2400F 2.0E 3-6-13

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 6-2-14 oc bracing. Except:

10-0-0 oc bracing: 14-16, 17-19

REACTIONS. (size) 1=Mechanical, 12=0-8-0Max Horz 12=230(LC 11)Max Uplift 1=-595(LC 12), 12=-590(LC 12)Max Grav 1=2061(LC 1), 12=2069(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 7-8=-387/221, 8-9=-4257/1667, 9-10=-4263/1562, 10-12=-4257/1506, 4-5=-3892/1571,

5-6=-3911/1571, 6-8=-3553/1404, 1-3=-3881/1403, 3-4=-3337/1307, 6-7=-389/206BOT CHORD 13-14=-134/360, 12-13=-1224/3800, 9-16=-438/275, 16-17=-1021/3492, 5-17=-646/387,

1-21=-1132/3370, 20-21=-1135/3368, 19-20=-96/270WEBS 10-13=-452/270, 13-16=-1111/3490, 8-17=-267/773, 3-20=-467/260, 8-16=-415/1200,

4-17=-384/1149, 17-20=-822/2760

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 15-1-6, Exterior(2) 15-1-6 to18-1-6, Interior(1) 18-1-6 to 25-3-8, Exterior(2) 25-3-8 to 28-3-8, Interior(1) 28-3-8 to 42-1-0 zone; cantilever right exposed ;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Refer to girder(s) for truss to truss connections.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=595, 12=590.8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 33: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A18

Truss Type

Roof Special

Qty

1

Ply

1

Job Reference (optional)

T20992395

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:21 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-7bOELMQXzvIOj3RzAZGOAkBAfaSdTfptZhBhz6youGy

Scale = 1:73.9

7

8

9

10

11

64 5

1

2

3

1413 12

16 15

21 20 19 1817

22

23

24

25

26

27

28 29

6x8

6x8 5x6

7x10

5x8

5x6

2x4

7x10

5x6

6x8

5x12 7x10

3x6

6x8

3x4

2x4 2x4

8x10

5x6

5x6

5x8 20-6-021-8-0

0-4-00-4-0

6-0-135-8-12

11-10-85-9-11

15-11-84-1-0

20-0-84-1-0

20-8-00-7-8

21-8-0

1-0-0

26-6-04-10-0

27-6-01-0-0

33-10-66-4-6

39-8-05-9-10

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

6-0-135-8-12

11-10-85-9-11

15-11-84-1-0

20-0-84-1-0

20-8-00-7-8

24-1-03-5-0

27-6-03-5-0

33-10-66-4-6

39-8-05-9-10

41-2-81-6-8

1-0-

4

5-11

-10

7-7-

13

0-6-

3

1-0-

0

5-11

-10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [4:0-3-0,0-2-4], [9:0-3-0,0-3-0], [11:0-4-7,0-4-0], [11:Edge,0-4-5], [12:0-3-8,0-3-0], [13:0-3-0,0-0-0], [15:0-5-0,0-3-0], [16:0-4-0,Edge],[19:0-1-12,0-2-12], [20:0-4-12,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.930.880.95

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.39

-0.89-0.23

(loc)17

15-161

l/defl>999>551

n/a

L/d240180n/a

PLATESMT20

Weight: 292 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

7-9: 2x4 SP No.1, 1-4: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

8-13: 2x4 SP No.3, 15-16: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

12-15,16-19: 2x4 SP No.2SLIDER Left 2x6 SP No.2 3-0-0, Right 2x8 SP 2400F 2.0E 3-6-13

BRACING-TOP CHORD Structural wood sheathing directly applied.BOT CHORD Rigid ceiling directly applied or 6-5-11 oc bracing. Except:

10-0-0 oc bracing: 13-15WEBS 1 Row at midpt 7-16, 6-18

REACTIONS. (size) 1=Mechanical, 11=0-8-0Max Horz 11=-230(LC 10)Max Uplift 1=-591(LC 12), 11=-586(LC 12)Max Grav 1=2067(LC 1), 11=2076(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 7-8=-4279/1683, 8-9=-4288/1566, 9-11=-4275/1516, 6-7=-5006/1990, 4-5=-3638/1492,

5-6=-4563/1767, 1-3=-3829/1393, 3-4=-3499/1374BOT CHORD 12-13=-148/335, 11-12=-1226/3817, 8-15=-446/313, 15-16=-911/3249, 1-21=-1134/3318,

20-21=-1134/3318, 19-20=-1005/3174WEBS 9-12=-457/266, 12-15=-1091/3542, 7-15=-474/1394, 7-16=-975/2482, 5-16=-419/1406,

5-19=-1389/532, 4-19=-286/820, 4-20=-38/314, 16-19=-1154/3613, 6-16=-2200/965

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 13-1-0, Exterior(2) 13-1-0 to16-1-0, Interior(1) 16-1-0 to 25-3-8, Exterior(2) 25-3-8 to 28-3-8, Interior(1) 28-3-8 to 42-1-0 zone; cantilever right exposed ;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members, with BCDL = 10.0psf.6) Refer to girder(s) for truss to truss connections.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=591, 11=586.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 34: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A19

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992396

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:09:31 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-3o0gaiB12MQ4aggSA8q2WfIz_LQk_w?_pyIjSzyou_2

Scale = 1:75.0

14

15

16

17

4 56

9 11 1213

1

2

3

7

8

10

2120 19 18

23 22

28 27 26 2524

3031

32

33 34 35

36

37

5x12

7x10

5x8

3x4

5x6

7x10 6x8

3x4

6x12 MT20HS

5x6 3x6

6x8 7x10

3x4

5x6

3x4

2x4 3x4

2x4

5x8

2x4 2x4

5x6

2x4

6x8

5x6

5x6

4x6

12-3-04-10-84-10-8

0-4-00-4-0

5-3-34-11-3

9-11-34-8-0

15-4-45-5-1

20-8-05-3-12

21-8-01-0-0

26-6-04-10-0

27-6-01-0-0

30-1-82-7-8

34-9-124-8-4

39-8-04-10-4

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

5-3-34-11-3

9-11-34-8-0

10-7-00-7-13

15-4-44-9-4

20-8-05-3-12

24-1-03-5-0

27-6-03-5-0

30-1-82-7-8

34-9-124-8-4

39-8-04-10-4

41-2-81-6-8

1-0-

4

5-1-

10

7-7-

13

0-6-

3

1-0-

0

5-1-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [4:0-5-4,0-2-8], [9:0-3-0,0-3-0], [14:0-3-0,0-2-4], [17:0-5-7,0-4-0], [19:0-3-0,0-3-0], [22:0-7-12,0-3-4], [23:0-4-0,Edge], [26:0-1-12,0-2-12], [27:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.880.880.84

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.38

-0.78-0.22

(loc)24

22-231

l/defl>999>631

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 312 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

1-4,9-14: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

12-20: 2x4 SP No.3, 22-23: 2x4 SP No.1WEBS 2x4 SP No.3 *Except*

19-22,23-26: 2x4 SP No.2SLIDER Left 2x6 SP No.2 3-0-0, Right 2x8 SP 2400F 2.0E 3-0-10

BRACING-TOP CHORD Structural wood sheathing directly applied. Except:

1 Row at midpt 6-11, 11-13BOT CHORD Rigid ceiling directly applied or 5-5-1 oc bracing. Except:

10-0-0 oc bracing: 20-22JOINTS 1 Brace at Jt(s): 11

REACTIONS. (lb/size) 1=1943/Mechanical, 17=1850/0-8-0Max Horz 17=-195(LC 10)Max Uplift 1=-549(LC 12), 17=-533(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 14-31=-3314/1454, 15-31=-3328/1432, 15-16=-3682/1540, 16-17=-3769/1517,

4-32=-3831/1667, 32-33=-3835/1666, 33-34=-3841/1665, 5-34=-3842/1665, 5-35=-4875/2026, 6-35=-4875/2026, 6-9=-4875/2026, 9-11=-4895/2027, 11-12=-4895/2197, 12-13=-4120/1769, 13-14=-4121/1769, 1-2=-3538/1366, 2-36=-3425/1371, 3-36=-3414/1383, 3-37=-3342/1378, 4-37=-3296/1398

BOT CHORD 18-19=-1139/3356, 17-18=-1139/3356, 12-22=-553/376, 22-23=-1310/4164, 1-28=-1111/3043, 27-28=-1111/3043, 26-27=-1022/3021

WEBS 15-19=-482/247, 14-19=-739/206, 19-22=-869/3029, 14-22=-686/2002, 12-23=-473/956, 5-23=-449/1274, 5-26=-1312/627, 4-26=-462/1131, 9-23=-415/345, 23-26=-1322/3723

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 11-5-14, Exterior(2)11-5-14 to 15-8-12, Interior(1) 15-8-12 to 25-2-13, Exterior(2) 31-4-0 to 35-6-15, Interior(1) 35-6-15 to 42-1-0 zone; cantilever rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 549 lb uplift at joint 1 and 533 lb uplift

at joint 17.9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 35: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A20

Truss Type

Roof Special

Qty

1

Ply

1Job Reference (optional)

T20992397

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:24:22 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-UCLWaNzwD7hfzbIitmJ_7YiCsWXSFsX7h3dNDqyotm7

Scale = 1:77.9

17

1819

20

5 67

10 12 1315

4

1

2

3

11

14168

9

2322 21

25 24

30 29 28 2726

31 32 33 34 35

36

37

38397x10

7x10

5x8

4x6

4x6

8x10 6x8

2x4

8x14 MT20HS

8x14 MT20HS

8x14 MT20HS

5x6

4x6

2x4

5x6

3x4

2x4

6x8

3x4

2x4

3x4

2x4

6x8

10x12

7x10

5x6

5x6

5x8 20-6-021-8-0

0-4-00-4-0

5-5-85-1-8

13-3-87-10-0

16-10-143-7-6

20-8-03-9-2

21-8-01-0-0

26-6-04-10-0

27-6-01-0-0

32-1-84-7-8

39-8-07-6-8

40-0-00-4-0

41-2-8

1-2-8

0-4-00-4-0

5-5-85-1-8

10-7-05-1-8

13-3-82-8-8

16-10-143-7-6

19-2-82-3-10

20-8-01-5-8

24-1-03-5-0

27-6-03-5-0

28-11-81-5-8

32-1-83-2-0

36-0-153-11-7

39-8-03-7-1

41-2-81-6-8

1-0-

4

4-3-

105-5-

37-7-

13

0-6-

3

1-0-

0

4-3-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-7-15,0-0-2], [12:0-4-0,0-2-4], [17:0-2-9,0-2-7], [20:Edge,0-4-5], [20:0-4-7,0-5-0], [21:0-2-8,0-3-0], [24:0-5-4,0-4-8], [25:0-8-4,0-4-0], [29:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.960.790.97

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.69

-1.12-0.28

(loc)2626

1

l/defl>712>440

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 324 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

12-17: 2x4 SP No.1, 1-4,5-12: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

24-25: 2x6 SP M 26WEBS 2x4 SP No.3 *Except*

21-24,17-24,4-29: 2x4 SP No.2, 25-28: 2x4 SP No.1SLIDER Left 2x6 SP No.2 3-0-0, Right 2x8 SP 2400F 2.0E 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 1-7-10 oc purlins.

Except: 1 Row at midpt 7-122 Rows at 1/3 pts 12-152-5-0 oc bracing: 6-7

BOT CHORD Rigid ceiling directly applied or 4-9-2 oc bracing. Except: 10-0-0 oc bracing: 22-24

WEBS 1 Row at midpt 10-24JOINTS 1 Brace at Jt(s): 12, 7

REACTIONS. (lb/size) 1=2108/Mechanical, 20=2136/0-8-0Max Horz 20=205(LC 11)Max Uplift 1=-715(LC 12), 20=-761(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 17-18=-4186/2285, 18-19=-4328/2350, 19-20=-4418/2332, 5-31=-5463/3085,

31-32=-5463/3085, 6-32=-5463/3085, 6-33=-7482/4163, 7-33=-7482/4163, 7-10=-7482/4163, 10-12=-6491/3700, 12-13=-6491/3610, 13-15=-6356/3612, 15-34=-6356/3612, 34-35=-6356/3612, 17-35=-6357/3612, 4-5=-5201/2861, 1-2=-3911/1882, 2-36=-3798/1887, 3-36=-3787/1897, 3-37=-3698/1956, 4-37=-3649/1970, 11-38=-268/225, 14-38=-308/206, 9-39=-311/194, 11-39=-268/214

BOT CHORD 21-22=-536/938, 20-21=-2117/3938, 13-24=-453/609, 24-25=-3958/7541, 1-30=-1549/3374, 29-30=-1556/3320, 28-29=-2433/4900

WEBS 17-21=-514/407, 21-24=-1514/2977, 17-24=-1730/3015, 6-25=-1360/2549, 5-29=-2736/1663, 4-29=-1800/3262, 14-15=-450/570, 7-9=-451/562, 12-14=-53/253, 9-12=-68/260, 10-24=-1358/972, 25-28=-2862/5492, 6-28=-2043/1266, 5-28=-615/832

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 11-9-8, Exterior(2)11-9-8 to 14-6-0, Interior(1) 19-2-0 to 25-3-8, Exterior(2) 14-6-0 to 17-6-0, Interior(1) 17-6-0 to 33-4-0, Exterior(2) 25-3-8 to 28-3-8,Interior(1) 28-3-8 to 42-1-0 zone; cantilever right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Refer to girder(s) for truss to truss connections.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 715 lb uplift at joint 1 and 761 lb uplift

at joint 20.Continued on page 2

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 36: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

A20

Truss Type

Roof Special

Qty

1

Ply

1Job Reference (optional)

T20992397

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:24:22 2020 Page 2 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-UCLWaNzwD7hfzbIitmJ_7YiCsWXSFsX7h3dNDqyotm7

NOTES-9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

Page 37: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

B03

Truss Type

Hip Girder

Qty

1

Ply

1

Job Reference (optional)

T20992398

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:25 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-?MdkBjT218oqCglkPPKKKaLrvCr8PUSTUJ9v6tyouGu

Scale = 1:35.5

1

2

3 4 5

6

10 9 87

11 12 13 14 15 16

17 18 19 20

5x8

4x6

5x6

2x4 7x10

5x6 2x4

6x8

4x6

3x4

0-0-120-0-12

0-4-11

0-3-15

5-9-85-4-13

10-7-04-9-8

15-4-84-9-8

20-9-85-5-0

0-0-120-0-12

0-4-11

0-3-15

5-9-85-4-13

10-7-04-9-8

15-4-84-9-8

20-9-85-5-0

1-0-

4

3-5-

3

1-2-

2

3-5-

3

5.00 12

Plate Offsets (X,Y)-- [3:0-3-0,0-2-4], [5:0-3-0,0-2-4], [8:0-3-8,0-3-0], [9:0-5-0,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.970.710.84

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.15

-0.230.04

(loc)9

9-107

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 124 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

1-3: 2x4 SP M 31BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x6 SP No.2 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied, except end verticals.BOT CHORD Rigid ceiling directly applied or 6-11-8 oc bracing.

REACTIONS. (size) 1=Mechanical, 7=0-3-8Max Horz 1=86(LC 7)Max Uplift 1=-706(LC 8), 7=-729(LC 8)Max Grav 1=1656(LC 1), 7=1688(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-2998/1325, 3-4=-3298/1543, 4-5=-3298/1543, 5-6=-2760/1237, 6-7=-1608/737BOT CHORD 1-10=-1120/2571, 9-10=-1124/2564, 8-9=-1082/2479, 7-8=-142/300WEBS 3-10=0/331, 3-9=-399/955, 4-9=-769/507, 5-9=-406/1010, 6-8=-941/2205

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.603) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Refer to girder(s) for truss to truss connections.7) Bearing at joint(s) 7 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify

capacity of bearing surface.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=706, 7=729.9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 257 lb down and 467 lb up at

7-0-0, 107 lb down and 187 lb up at 9-0-12, 107 lb down and 187 lb up at 11-0-12, 107 lb down and 187 lb up at 12-6-4, and 107 lbdown and 187 lb up at 14-6-4, and 313 lb down and 485 lb up at 16-7-0 on top chord, and 141 lb down and 29 lb up at 7-0-0, 60 lbdown at 9-0-12, 60 lb down at 11-0-12, 60 lb down at 12-6-4, and 60 lb down at 14-6-4, and 141 lb down and 29 lb up at 16-6-4on bottom chord. The design/selection of such connection device(s) is the responsibility of others.

10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Continued on page 2

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 38: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

B03

Truss Type

Hip Girder

Qty

1

Ply

1

Job Reference (optional)

T20992398

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:25 2020 Page 2 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-?MdkBjT218oqCglkPPKKKaLrvCr8PUSTUJ9v6tyouGu

LOAD CASE(S) StandardUniform Loads (plf)

Vert: 1-3=-80, 3-5=-80, 5-6=-80, 1-7=-20Concentrated Loads (lb)

Vert: 5=-257(B) 10=-87(B) 3=-257(B) 8=-87(B) 12=-107(B) 13=-107(B) 14=-107(B) 15=-107(B) 17=-41(B) 18=-41(B) 19=-41(B) 20=-41(B)

Page 39: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

B04

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992399

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:26:06 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-RDeqPxE9j4nvSaEhzcANLT?3NR8lc4ZRcFpttoyotkV

Scale = 1:36.2

1

2

3 4

5

6

7

10 98

11

12 13 14

3x8

4x6

4x6

5x6

3x8

7x10 2x4

5x6

3x6

3x4

4x6

0-0-120-0-12

0-4-9

0-3-13

7-9-87-4-15

13-4-85-7-0

20-9-87-5-0

0-0-120-0-12

0-4-9

0-3-13

7-9-87-4-15

13-4-85-7-0

20-9-87-5-0

1-0-

4

2-9-

11

1-4-

7

4-3-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-3-4,0-0-6], [3:0-3-0,0-2-4], [4:0-3-0,0-2-4], [6:0-3-4,0-2-8], [9:0-4-12,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.660.350.25

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.04-0.080.02

(loc)9-101-10

8

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 131 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3 *Except*

7-8: 2x6 SP No.2SLIDER Left 2x6 SP No.2 3-10-1

BRACING-TOP CHORD Structural wood sheathing directly applied or 3-5-15 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 8-9-15 oc bracing.

REACTIONS. (lb/size) 1=1028/Mechanical, 8=1028/0-3-8Max Horz 1=130(LC 12)Max Uplift 1=-297(LC 12), 8=-312(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-11=-1657/680, 2-11=-1533/682, 2-3=-1459/695, 3-12=-1282/664, 12-13=-1282/664,

13-14=-1282/664, 4-14=-1282/664, 4-5=-1401/641, 5-6=-1748/896, 6-8=-948/486, 5-7=-261/311

BOT CHORD 1-10=-646/1346, 9-10=-647/1340, 8-9=-553/814WEBS 3-10=0/286, 6-9=-106/655

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 9-0-0, Exterior(2)9-0-0 to 13-2-15, Interior(1) 13-2-15 to 14-7-0, Exterior(2) 14-7-0 to 18-0-11, Interior(1) 18-0-11 to 21-9-4 zone;C-C for membersand forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Refer to girder(s) for truss to truss connections.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 297 lb uplift at joint 1 and 312 lb uplift

at joint 8.8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 40: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

B05

Truss Type

Roof Special

Qty

1

Ply

1Job Reference (optional)

T20992400

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:27:54 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-G_9f4sYvIGOaPAVRIH6ijFUZSz_mwt?KR2_bfYyotip

Scale = 1:37.0

1

2

3

4 5

6

7

11 10 98

12

13

14 15

16

3x8

4x6

5x8 4x6

4x6

2x4

3x6 7x10 3x4

2x4

3x4

2x4

4x6

0-4-00-4-0

9-4-89-0-8

11-9-82-5-0

15-3-83-6-0

16-1-120-10-4

20-9-84-7-12

0-4-00-4-0

4-10-44-6-4

9-4-84-6-4

11-9-82-5-0

15-3-83-6-0

16-1-120-10-4

20-9-84-7-12

1-0-

4

3-5-

10

1-3-

9

4-11

-2

5.00 12

Plate Offsets (X,Y)-- [1:0-3-4,0-0-6], [4:0-5-12,0-2-8], [10:0-4-12,0-4-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.510.430.46

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.06-0.140.02

(loc)1-111-11

8

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 145 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x6 SP No.2 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 3-9-11 oc purlins,

except end verticals. Except: 4-6-0 oc bracing: 6-7

BOT CHORD Rigid ceiling directly applied or 9-4-8 oc bracing.

REACTIONS. (lb/size) 1=1032/Mechanical, 8=1032/0-4-0Max Horz 1=133(LC 11)Max Uplift 1=-305(LC 12), 8=-307(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-1706/727, 2-13=-1596/738, 3-13=-1585/747, 3-14=-1369/585, 4-14=-1295/599,

4-5=-1163/629, 5-15=-1260/630, 6-15=-1336/612, 6-16=-1426/634, 7-16=-1550/623, 7-8=-962/449

BOT CHORD 1-11=-609/1427, 10-11=-379/1203, 9-10=-520/1372WEBS 3-11=-294/260, 4-11=0/394, 5-10=-109/269, 6-10=-287/152, 7-9=-453/1210

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-2-8 to 4-2-8, Interior(1) 4-2-8 to 10-7-0, Exterior(2)10-7-0 to 16-0-0, Interior(1) 16-0-0 to 21-10-4 zone;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Refer to girder(s) for truss to truss connections.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 305 lb uplift at joint 1 and 307 lb uplift

at joint 8.8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 41: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ1

Truss Type

JACK-OPEN

Qty

20

Ply

1

Job Reference (optional)

T20992401

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:28 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QxJtplWwK3AO38TJ4Xu1yDzbgP2Tc2JvAHNZjCyouGr

Scale = 1:7.3

1

2

33x4

0-10-150-10-15

0-10-150-10-15

0-6-

3

0-10

-12

0-6-

6

0-10

-12

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.040.030.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.00-0.000.00

(loc)13

l/defln/rn/rn/a

L/d120120n/a

PLATESMT20

Weight: 3 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2

BRACING-TOP CHORD Structural wood sheathing directly applied or 0-10-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=MechanicalMax Horz 2=69(LC 1), 3=-71(LC 17)Max Uplift 2=-27(LC 12)Max Grav 2=90(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 42: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ3

Truss Type

JACK-OPEN

Qty

17

Ply

1

Job Reference (optional)

T20992402

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:28 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QxJtplWwK3AO38TJ4Xu1yDzZmP2Wc2JvAHNZjCyouGr

Scale = 1:11.5

1

2

36x8

3x12 MT20HS

1-2-81-2-8

1-6-80-4-0

2-10-151-4-7

2-10-152-10-15

0-6-

3

1-8-

12

1-4-

6 1-8-

12

5.00 12

Plate Offsets (X,Y)-- [1:0-3-13,0-1-6], [1:0-2-7,Edge]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.170.030.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.00-0.00-0.00

(loc)1

1-32

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 16 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-10-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=Mechanical, 1=0-8-0Max Horz 1=71(LC 12)Max Uplift 2=-71(LC 12), 1=-19(LC 12)Max Grav 2=104(LC 17), 3=50(LC 3), 1=126(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone; cantilever left exposed ;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 1.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 43: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ3A

Truss Type

Jack-Open

Qty

1

Ply

1

Job Reference (optional)

T20992403

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:29 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-u7tF15WZ5MIFhI2VeEPGUQWiCpKCLVZ3Px76FeyouGq

Scale = 1:15.8

1

4

2

3

3x4

2x4

3-0-73-0-7

3-0-73-0-7

1-3-

9

2-6-

12

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-R

0.310.190.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.01

-0.01-0.02

(loc)3-43-4

2

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 11 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 3-0-7 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 4=Mechanical, 2=Mechanical, 3=MechanicalMax Horz 4=63(LC 12)Max Uplift 4=-5(LC 12), 2=-76(LC 12), 3=-2(LC 12)Max Grav 4=141(LC 1), 2=110(LC 17), 3=57(LC 3)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2, 3.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 44: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ3B

Truss Type

Jack-Open

Qty

2

Ply

1

Job Reference (optional)

T20992404

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:29 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-u7tF15WZ5MIFhI2VeEPGUQWggpISLVZ3Px76FeyouGq

Scale = 1:11.5

1

2

33x4

2-10-152-10-15

2-10-152-10-15

0-6-

3

1-8-

12

0-4-

7

1-4-

6 1-8-

12

5.00 12

Plate Offsets (X,Y)-- [1:0-0-0,0-0-7]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.410.370.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.00-0.120.00

(loc)13

l/defln/rn/rn/a

L/d120120n/a

PLATESMT20

Weight: 9 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-10-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=MechanicalMax Horz 2=290(LC 1), 3=-296(LC 17)Max Uplift 2=-84(LC 12)Max Grav 2=285(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-267/376BOT CHORD 1-3=-313/314

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2.

PROVIDE ANCHORAGE, DESIGNED BY OTHERS, AT BEARINGS TO RESIST MAX. UPLIFT AND MAX HORZ. REACTIONS SPECIFIED BELOW.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 45: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ3C

Truss Type

Jack-Open

Qty

1

Ply

1

Job Reference (optional)

T20992405

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:30 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-MJQdERXBsgQ6ISdhCywV1e3w4DjV4yoCebsfo4youGp

Scale = 1:11.6

1

4

2

3

2x4

2x4

1-8-71-8-7

1-8-71-8-7

1-0-

4

1-8-

12

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-R

0.110.060.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.00-0.00-0.00

(loc)442

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 6 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 1-8-7 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 4=0-8-0, 2=Mechanical, 3=MechanicalMax Horz 4=35(LC 12)Max Uplift 2=-44(LC 12), 3=-3(LC 12)Max Grav 4=77(LC 1), 2=61(LC 17), 3=31(LC 3)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 3.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 46: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ5

Truss Type

JACK-OPEN

Qty

8

Ply

1

Job Reference (optional)

T20992406

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:31 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-qW_0SnYpd_YzwbCulfRkarb_gc23pP2LtFcDKXyouGo

Scale = 1:15.6

1

4

2

36x8

3x12 MT20HS

1-2-81-2-8

1-6-80-4-0

4-10-153-4-7

4-10-154-10-15

0-6-

3

2-6-

12

2-2-

6 2-6-

12

5.00 12

Plate Offsets (X,Y)-- [1:0-5-0,0-0-13], [1:0-2-7,Edge]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.570.100.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.01-0.01-0.00

(loc)1-31-3

2

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 24 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-10-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=Mechanical, 1=0-8-0Max Horz 1=115(LC 12)Max Uplift 2=-121(LC 12), 1=-39(LC 12)Max Grav 2=185(LC 17), 3=90(LC 3), 1=226(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 4-10-3 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)

2=121.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 47: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ5A

Truss Type

Jack-Open

Qty

2

Ply

1

Job Reference (optional)

T20992407

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:31 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-qW_0SnYpd_YzwbCulfRkarb3Vc_5pP2LtFcDKXyouGo

Scale = 1:15.6

1

2

6

5

7

3

4

2x4

3x4

4x6

6x8

3x12 MT20HS

1-2-81-2-8

1-6-80-4-0

3-10-82-4-0

4-10-151-0-7

3-10-83-10-8

4-10-151-0-7

0-6-

3

2-6-

12

1-6-

12

2-2-

6

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:0-5-0,0-1-1], [1:0-2-7,Edge]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-R

0.200.360.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.01-0.01-0.01

(loc)664

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 25 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2 *Except*

1-6: 2x6 SP No.2, 2-6: 2x4 SP No.3WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-10-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 3=Mechanical, 4=Mechanical, 1=0-8-0Max Horz 1=115(LC 12)Max Uplift 3=-43(LC 12), 4=-52(LC 12), 1=-39(LC 12)Max Grav 3=94(LC 17), 4=136(LC 17), 1=226(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-265/93

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 4-10-3 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4, 1.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 48: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

CJ5C

Truss Type

Jack-Open

Qty

1

Ply

1

Job Reference (optional)

T20992408

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:32 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:sl2nLp9_lSbiO3w3_x0pcqy9R64-IiYOf6ZROHgqYln4JNyz638BB0M1YsIV5vLmszyouGn

Scale = 1:15.7

1

4

5

2

3

3x4

2x4

3-8-73-8-7

3-8-73-8-7

1-0-

4

2-6-

12

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-R

0.390.250.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.02

-0.02-0.03

(loc)3-43-4

2

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 12 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 3-8-7 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 4=Mechanical, 2=Mechanical, 3=MechanicalMax Horz 4=78(LC 12)Max Uplift 4=-18(LC 12), 2=-87(LC 12)Max Grav 4=175(LC 1), 2=133(LC 17), 3=70(LC 3)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-1-12 to 3-1-12, Interior(1) 3-1-12 to 3-7-11 zone;C-C formembers and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4, 2.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 49: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

D5

Truss Type

Hip Girder

Qty

1

Ply

1

Job Reference (optional)

T20992409

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:33 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-mu6mtSZ39boh9vMGt4TCfGhJMQitHIVeKZ5KOPyouGm

Scale = 1:25.6

1

2

3 4

5

6

8 7

9 10 11

12 13

5x8 4x6

2x4 3x4 4x6

5x6

3x4

4x6

5x6

3x4

1-2-81-2-8

1-6-80-4-0

5-0-03-5-8

10-5-05-5-0

13-10-83-5-8

14-2-80-4-0

15-5-01-2-8

1-6-81-6-8

5-0-03-5-8

10-5-05-5-0

13-10-83-5-8

15-5-01-6-8

0-6-

3

2-7-

3

0-6-

3

2-7-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0], [3:0-5-12,0-2-8], [6:0-6-7,0-2-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.620.210.07

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.02-0.040.01

(loc)7-87-8

6

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 92 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 2-11-4, Right 2x8 SP 2400F 2.0E 2-11-4

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-10-1 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 1=0-8-0, 6=0-8-0Max Horz 1=-70(LC 6)Max Uplift 1=-246(LC 8), 6=-246(LC 8)Max Grav 1=659(LC 1), 6=659(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-1100/441, 3-4=-939/438, 4-6=-1095/437BOT CHORD 1-8=-326/940, 7-8=-322/944, 6-7=-322/936

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.603) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=246, 6=246.7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 236 lb up at 5-0-0, 99 lb up at

7-0-12, and 99 lb up at 8-4-4, and 236 lb up at 10-5-0 on top chord, and 54 lb up at 5-0-0, 2 lb down and 19 lb up at 7-0-12, and 2lb down and 19 lb up at 8-4-4, and 54 lb up at 10-4-4 on bottom chord. The design/selection of such connection device(s) is theresponsibility of others.

8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-3=-80, 3-4=-80, 4-6=-80, 1-6=-20

Concentrated Loads (lb)Vert: 3=17(F) 4=17(F) 8=45(F) 7=45(F) 9=5(F) 11=5(F) 12=11(F) 13=11(F)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 50: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

D6

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992410

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:29:29 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-_GPZ0LhVwSM5InGiMkK_4HwlTGR3gw5JHKV6VXyothK

Scale: 1/2"=1'

1

2

3 4

5

6

8 7

9

10

11

12

13

4x6 4x6

3x12 MT20HS

5x6

2x4 2x4 4x6

5x6

5x6

3x4

1-2-81-2-8

1-6-80-4-0

7-0-05-5-8

8-5-01-5-0

13-10-05-5-0

1-6-81-6-8

7-0-05-5-8

8-5-01-5-0

13-10-05-5-0

0-6-

3

3-5-

3

1-2-

2

3-5-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.700.300.10

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.03-0.070.01

(loc)1-81-8

6

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 83 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-5-8, Right 2x8 SP 2400F 2.0E 3-1-1

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-4-5 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (lb/size) 6=675/0-3-8, 1=675/0-8-0Max Horz 1=-97(LC 10)Max Uplift 6=-200(LC 12), 1=-200(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-9=-983/456, 9-10=-877/458, 2-10=-876/459, 2-3=-852/477, 3-11=-785/519,

4-11=-785/519, 4-12=-840/512, 5-12=-884/501, 5-13=-952/490, 6-13=-984/485BOT CHORD 1-8=-296/786, 7-8=-290/785, 6-7=-286/775WEBS 4-7=-96/272

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 7-0-0, Exterior(2)7-0-0 to 12-7-15, Interior(1) 12-7-15 to 13-10-0 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 200 lb uplift at joint 6 and 200 lb uplift

at joint 1.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 51: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

D7

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992411

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:30:25 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-M2nkmUNdkfQ90OYTeVK6L5EHmrYroEpZA234TIyotgS

Scale = 1:25.4

1

2

3

4

5

6

8

7

9

1011

4x6

4x6

2x4

4x6

2x4

4x6

4x6

5x6

5x6

3x4

1-2-81-2-8

1-6-80-4-0

7-8-86-2-0

13-10-06-1-8

1-6-81-6-8

7-8-86-2-0

13-10-06-1-8

0-6-

3

2-2-

3

1-3-

9

2-2-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.870.320.18

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.03

-0.060.01

(loc)1-81-8

7

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 85 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3 *Except*

6-7: 2x4 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-9-2

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (lb/size) 7=668/0-3-8, 1=668/0-8-0Max Horz 1=97(LC 12)Max Uplift 7=-204(LC 12), 1=-191(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-9=-951/367, 2-9=-834/368, 2-10=-811/372, 3-10=-801/389, 3-11=-811/388,

4-11=-829/374, 4-5=-1040/542, 5-7=-623/329BOT CHORD 1-8=-327/749, 7-8=-279/416WEBS 3-8=0/268, 5-8=-136/462

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 7-8-8, Exterior(2)7-8-8 to 10-8-8, Interior(1) 10-8-8 to 13-8-4 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 204 lb uplift at joint 7 and 191 lb uplift

at joint 1.7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 52: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

D8

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992412

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:31:06 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-fwmENWsL4FaLRhALYcZkVkRHfMYUvmCbbwUkOPyotfp

Scale = 1:25.4

1

2

3

4

5

6

8

7

9

10

4x6

3x6

2x4

4x6

2x4

4x6

4x6

5x6

5x6

3x4

1-2-81-2-8

1-6-80-4-0

7-8-86-2-0

13-10-06-1-8

1-6-81-6-8

7-8-86-2-0

13-10-06-1-8

0-6-

3

3-0-

3

1-3-

9

3-0-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.850.310.23

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.03

-0.060.01

(loc)1-81-8

7

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 89 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-9-2

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (lb/size) 7=668/0-3-8, 1=668/0-8-0Max Horz 1=142(LC 12)Max Uplift 7=-212(LC 12), 1=-184(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-9=-954/325, 2-9=-838/326, 2-10=-815/330, 3-10=-803/347, 3-4=-770/372,

4-5=-814/387, 5-7=-623/331BOT CHORD 1-8=-365/753WEBS 3-8=0/252, 5-8=-314/592

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 7-8-8, Exterior(2)7-8-8 to 9-4-11, Interior(1) 9-4-11 to 13-8-4 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 212 lb uplift at joint 7 and 184 lb uplift

at joint 1.7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 53: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

D9

Truss Type

Hip

Qty

1

Ply

1Job Reference (optional)

T20992413

8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:31:56 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-BYn8tcTiIctERN?yT6SSXHVq6WcAcMwy5icN9Wyotf1

Scale = 1:25.4

1

2

3 4

5

6

8

7

9

10

4x6

3x4

2x4

4x6

3x4

4x6

4x6

5x6

5x6

3x4

1-2-81-2-8

1-6-80-4-0

7-8-86-2-0

13-10-06-1-8

1-6-81-6-8

7-8-86-2-0

13-10-06-1-8

0-6-

3

3-5-

10

1-3-

9

3-5-

10

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.850.310.27

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.03

-0.060.01

(loc)1-81-8

7

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 91 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-9-2

BRACING-TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins,

except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (lb/size) 7=668/0-3-8, 1=668/0-8-0Max Horz 1=166(LC 12)Max Uplift 7=-217(LC 12), 1=-179(LC 12)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-9=-953/310, 2-9=-837/314, 2-10=-814/315, 3-10=-802/329, 3-4=-729/362,

4-5=-768/383, 5-7=-624/340BOT CHORD 1-8=-383/751WEBS 5-8=-388/693

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 7-8-8, Exterior(2)7-8-8 to 8-3-10, Interior(1) 8-3-10 to 13-8-4 zone; cantilever left exposed ;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 217 lb uplift at joint 7 and 179 lb uplift

at joint 1.7) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.

LOAD CASE(S) Standard

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 54: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

E1

Truss Type

Hip Girder

Qty

1

Ply

1

Job Reference (optional)

T20992414

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:37 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-fgLHiqdaCpJ7eXf26wY8p6r4O12QD4mEFB3XXAyouGi

Scale = 1:20.5

1

2

3 4

5

6

9

8

7

10

11 123x4

5x6 5x6

3x4

2x4

3x4

3x4

3x4

2x4

2-10-82-10-8

3-0-80-2-0

6-1-83-1-0

9-2-83-1-0

9-4-80-2-0

12-3-02-10-8

3-0-83-0-8

5-0-01-11-8

7-3-02-3-0

9-2-81-11-8

12-3-03-0-8

0-6-

3

2-7-

3

0-6-

3

2-7-

3

5.00 12

Plate Offsets (X,Y)-- [3:0-3-0,0-2-4], [4:0-3-0,0-2-4]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.240.300.18

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.010.02

-0.01

(loc)7-88-9

7

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 57 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 10-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.

REACTIONS. (size) 9=0-4-0, 7=0-4-0Max Horz 9=-73(LC 6)Max Uplift 9=-709(LC 8), 7=-621(LC 9)Max Grav 9=392(LC 17), 7=397(LC 18)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-165/351, 2-3=-77/302, 3-4=0/628, 4-5=-54/300, 5-6=-104/349BOT CHORD 1-9=-261/176, 8-9=-525/0, 7-8=-506/0, 6-7=-259/106WEBS 2-9=-265/175, 3-9=-136/594, 3-8=-328/0, 4-8=-329/0, 4-7=-134/596, 5-7=-264/158

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; porch left and right exposed; Lumber DOL=1.60plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

9=709, 7=621.7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 246 lb up at 5-0-0, and 29 lb

down and 138 lb up at 6-1-8, and 246 lb up at 7-3-0 on top chord, and 313 lb up at 5-0-0, and 14 lb down and 41 lb up at 6-1-8,and 313 lb up at 7-2-3 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.

8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-3=-80, 3-4=-80, 4-6=-80, 1-6=-20

Concentrated Loads (lb)Vert: 3=38(B) 4=38(B) 8=-6(B) 10=-29(B) 11=215(B) 12=215(B)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 55: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

E2

Truss Type

Common

Qty

1

Ply

1

Job Reference (optional)

T20992415

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:37 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-fgLHiqdaCpJ7eXf26wY8p6rz91_RD3gEFB3XXAyouGi

Scale = 1:21.1

1

2

3

5

4

67

3x4

5x6

3x4

2x4 2x4

2-10-82-10-8

3-0-80-2-0

9-2-86-2-0

9-4-80-2-0

12-3-02-10-8

6-1-86-1-8

12-3-06-1-8

0-6-

3

3-0-

13

0-6-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-0-0,0-0-11], [3:0-0-0,0-0-11]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.700.550.25

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.100.080.00

(loc)4-54-5

4

l/defl>812>990

n/a

L/d240180n/a

PLATESMT20

Weight: 51 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 7-3-3 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.

REACTIONS. (size) 5=0-4-0, 4=0-4-0Max Horz 5=-88(LC 10)Max Uplift 5=-442(LC 12), 4=-304(LC 9)Max Grav 5=613(LC 1), 4=613(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-445/574, 2-3=-448/574BOT CHORD 1-5=-441/498, 3-4=-441/502WEBS 2-5=-692/610, 2-4=-692/614

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-0-0 to 3-0-0, Interior(1) 3-0-0 to 6-1-8, Exterior(2) 6-1-8 to9-1-8, Interior(1) 9-1-8 to 12-3-0 zone; cantilever left and right exposed ; porch left and right exposed;C-C for members and forces &MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

5=442, 4=304. This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 56: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

EJ5

Truss Type

Jack-Open

Qty

3

Ply

1

Job Reference (optional)

T20992416

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:38 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-7svfwAdCz7R_GgEEfd3NMKO9aRReyZnNUro54dyouGh

Scale = 1:15.8

1 4

5

2

36x8

3x12 MT20HS

1-2-81-2-8

1-6-80-4-0

5-0-03-5-8

5-0-05-0-0

0-6-

3

2-7-

3

2-2-

13 2-7-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-4-7,0-1-0], [1:0-2-7,Edge]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.590.110.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.01-0.01-0.00

(loc)1-31-3

2

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 24 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=Mechanical, 1=0-8-0Max Horz 1=117(LC 12)Max Uplift 2=-124(LC 12), 1=-40(LC 12)Max Grav 2=189(LC 17), 3=92(LC 3), 1=230(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 4-11-4 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)

2=124.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 57: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

EJ5A

Truss Type

Jack-Open

Qty

4

Ply

1

Job Reference (optional)

T20992417

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:39 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-b2T17WeqkRZrtqpQDLacuXwLArnth01XiVYec3youGg

Scale = 1:15.8

1

2

5

6

3

46x8

3x12 MT20HS

1-2-81-2-8

1-6-80-4-0

5-0-03-5-8

-1-4-01-4-0

5-0-05-0-0

0-6-

3

2-7-

3

2-2-

13 2-7-

3

5.00 12

Plate Offsets (X,Y)-- [2:0-3-13,0-1-9], [2:0-2-7,Edge]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.540.110.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.01-0.01-0.00

(loc)2-42-4

3

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 27 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 3=Mechanical, 4=Mechanical, 2=0-8-0Max Horz 2=152(LC 12)Max Uplift 3=-101(LC 12), 2=-180(LC 12)Max Grav 3=167(LC 17), 4=92(LC 3), 2=388(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-4-0 to 1-8-0, Interior(1) 1-8-0 to 4-11-4 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

3=101, 2=180.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 58: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

EJ7

Truss Type

JACK-OPEN

Qty

25

Ply

1

Job Reference (optional)

T20992418

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:40 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-3E1PLsfSVkhiV_Ocn25rRlTSYF56QTHgx9HB8VyouGf

Scale = 1:19.8

1

2

5

6

3

44x6

3x4

3x4

6x8

1-2-81-2-8

1-6-80-4-0

7-0-05-5-8

7-0-07-0-0

0-6-

3

3-5-

3

3-0-

13 3-5-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-6-7,0-2-0], [1:0-3-15,0-4-11]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.820.240.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.03-0.06-0.02

(loc)1-41-4

3

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 38 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.1BOT CHORD 2x6 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-5-8

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-7-8 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 3=Mechanical, 4=Mechanical, 1=0-8-0Max Horz 1=162(LC 12)Max Uplift 3=-174(LC 12), 1=-61(LC 12)Max Grav 3=270(LC 17), 4=132(LC 3), 1=330(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 6-11-4 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)

3=174.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 59: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

EJ7A

Truss Type

Jack-Open

Qty

4

Ply

1

Job Reference (optional)

T20992419

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:41 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-XRbnYBg4G2pY78zpLmd4zy0eKeQQ9wXqAp1lgyyouGe

Scale = 1:19.8

1

4

5

6

2

3

10x16 MT20HS

3x12 MT20HS

5x6 3x4

1-2-81-2-8

3-10-82-8-0

1-6-81-6-8

3-10-82-4-0

7-0-03-1-8

0-6-

3

3-5-

3

2-5-

3

3-0-

13

1-0-

0

5.00 12

Plate Offsets (X,Y)-- [1:2-8-8,Edge], [1:0-5-8,Edge], [1:0-2-8,0-3-4], [1:2-1-9,0-10-4]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.750.230.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.04-0.08-0.00

(loc)442

l/defl>999>781

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 37 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 2=Mechanical, 3=Mechanical, 1=0-8-0Max Horz 1=123(LC 12)Max Uplift 2=-141(LC 12), 1=-33(LC 12)Max Grav 2=225(LC 17), 3=132(LC 3), 1=314(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 1-5-0 to 4-5-0, Interior(1) 4-5-0 to 6-11-4 zone; cantilever leftexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

2) All plates are MT20 plates unless otherwise indicated. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.5) Refer to girder(s) for truss to truss connections.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1 except (jt=lb)

2=141.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 60: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

F1

Truss Type

HIP GIRDER

Qty

1

Ply

1

Job Reference (optional)

T20992420

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:42 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-?d9AlXgj1MxPlIY?uT8JW9Yn12a4uE?zOTmIDOyouGd

Scale = 1:43.1

1

2

3 4 5 6

7

8

14 13 12 11 10 9

15 16 17 18 19

20 21 22

5x8 5x6

3x4

6x8

7x10

2x4

7x10

5x8

5x8

6x8

2x4 2x4 7x10

5x6

5x6

3x8 7x10

5x6 5x6

3x8

Special

Special

Special

Special

Special

Special

Special

Special

Special

Special

Special

Special

Special

Special

1-2-81-2-8

1-6-80-4-0

3-7-52-0-13

7-0-03-4-11

10-11-93-11-9

14-9-73-9-13

18-9-03-11-9

22-1-113-4-11

24-2-82-0-13

24-6-80-4-0

25-9-01-2-8

3-7-53-7-5

7-0-03-4-11

10-11-93-11-9

14-9-73-9-13

18-9-03-11-9

22-1-113-4-11

25-9-03-7-5

0-6-

3

3-5-

3

0-6-

3

3-5-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-0-10,0-0-1], [1:2-3-11,0-2-8], [1:0-4-7,0-5-0], [2:0-3-6,0-2-4], [3:0-5-12,0-2-8], [6:0-3-0,0-2-4], [7:0-3-6,0-2-0], [8:0-10-4,0-9-12], [8:0-4-7,0-5-0],[8:1-6-4,0-0-1], [11:0-5-0,0-4-12], [12:0-5-0,0-4-12]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.880.970.63

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.26

-0.380.11

(loc)11-1211-12

8

l/defl>999>790

n/a

L/d240180n/a

PLATESMT20

Weight: 170 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

3-6: 2x4 SP No.1BOT CHORD 2x6 SP No.2 *Except*

11-12: 2x6 SP M 26WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-1-0, Right 2x8 SP 2400F 2.0E 3-1-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 1-10-13 oc purlins.BOT CHORD Rigid ceiling directly applied or 4-8-15 oc bracing.

REACTIONS. (size) 1=0-8-0, 8=0-8-0Max Horz 1=-86(LC 6)Max Uplift 1=-1074(LC 8), 8=-1093(LC 8)Max Grav 1=2227(LC 1), 8=2256(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-4557/2195, 2-3=-4558/2254, 3-4=-5283/2628, 4-5=-5283/2628, 5-6=-4280/2177,

6-7=-4612/2289, 7-8=-4625/2241BOT CHORD 1-14=-1908/4040, 13-14=-1908/4040, 12-13=-1925/4191, 11-12=-2459/5334,

10-11=-2459/5334, 9-10=-1949/4101, 8-9=-1949/4101WEBS 2-13=-381/449, 3-13=-95/434, 3-12=-664/1435, 4-12=-695/523, 5-11=0/342,

5-10=-1395/639, 6-10=-459/1135, 7-10=-394/451

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=5.0psf; BCDL=5.0psf; h=28ft; B=45ft; L=26ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.603) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=1074, 8=1093.7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 240 lb down and 218 lb up at

7-0-0, 257 lb down and 216 lb up at 9-0-12, 257 lb down and 216 lb up at 11-0-12, 257 lb down and 216 lb up at 12-10-8, 257 lbdown and 216 lb up at 14-8-4, and 257 lb down and 216 lb up at 16-8-4, and 302 lb down and 366 lb up at 18-9-0 on top chord,and 220 lb down and 125 lb up at 7-0-0, 92 lb down at 9-0-12, 92 lb down at 11-0-12, 92 lb down at 12-10-8, 92 lb down at 14-8-4, and 92 lb down at 16-8-4, and 220 lb down and 125 lb up at 18-8-4 on bottom chord. The design/selection of such connectiondevice(s) is the responsibility of others.

8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) StandardContinued on page 2

"Special" indicates special hanger(s) or other connection device(s)required at location(s)shown. The design/selection of such special connection device(s) is the responsibility of others. This applies to all applicable truss designs in this job.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 61: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

F1

Truss Type

HIP GIRDER

Qty

1

Ply

1

Job Reference (optional)

T20992420

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:42 2020 Page 2 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-?d9AlXgj1MxPlIY?uT8JW9Yn12a4uE?zOTmIDOyouGd

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-3=-80, 3-6=-80, 6-8=-80, 1-8=-20

Concentrated Loads (lb)Vert: 3=-184(F) 6=-246(F) 13=-197(F) 12=-46(F) 4=-184(F) 11=-46(F) 5=-184(F) 10=-197(F) 15=-184(F) 17=-184(F) 19=-184(F) 20=-46(F) 21=-46(F) 22=-46(F)

Page 62: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

F2

Truss Type

Hip

Qty

1

Ply

1

Job Reference (optional)

T20992421

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:44 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-y0HwADizZzB7_biO0uAnbaeCbsONMFBGsmFPHGyouGb

Scale = 1:43.2

1

2

3

4 5

6

7

8

15 1413 12 11

10 9

16

17 18 19 20

21

5x8 5x8

4x6 3x4

3x4 3x4

4x6

3x4

2x4

3x4

2x4 6x8

5x6

3x4 6x8

5x6

3x4

1-2-81-2-8

1-6-80-4-0

5-0-03-5-8

9-0-04-0-0

12-10-83-10-8

16-9-03-10-8

20-9-04-0-0

24-2-83-5-8

24-6-80-4-0

25-9-01-2-8

1-6-81-6-8

5-0-03-5-8

9-0-04-0-0

16-9-07-9-0

20-9-04-0-0

24-2-83-5-8

25-9-01-6-8

0-6-

3

4-3-

3

0-6-

3

4-3-

3

5.00 12

Plate Offsets (X,Y)-- [1:0-5-7,0-4-0], [4:0-4-0,0-2-2], [5:0-4-0,0-2-2], [8:0-5-7,0-4-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.560.470.13

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.08

-0.150.06

(loc)12-1412-14

8

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 159 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2 *Except*

4-5: 2x4 SP M 31BOT CHORD 2x6 SP No.2 *Except*

11-13: 2x4 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 3-0-0, Right 2x8 SP 2400F 2.0E 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 3-9-1 oc purlins.BOT CHORD Rigid ceiling directly applied or 7-1-9 oc bracing.

REACTIONS. (size) 1=0-8-0, 8=0-8-0Max Horz 1=123(LC 11)Max Uplift 1=-372(LC 12), 8=-372(LC 12)Max Grav 1=1254(LC 1), 8=1254(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-2431/1032, 3-4=-2062/952, 4-5=-1874/895, 5-6=-2062/952, 6-8=-2431/1032BOT CHORD 1-15=-863/2139, 14-15=-863/2139, 12-14=-692/1866, 10-12=-686/1866, 9-10=-857/2139,

8-9=-857/2139WEBS 4-14=-61/310, 5-10=-61/310, 3-14=-350/199, 6-10=-349/199

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-4-0 to 3-4-0, Interior(1) 3-4-0 to 9-0-6, Exterior(2) 9-0-6 to13-3-4, Interior(1) 13-3-4 to 16-8-10, Exterior(2) 16-8-10 to 20-11-9, Interior(1) 20-11-9 to 25-5-0 zone; cantilever left and rightexposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60

3) Provide adequate drainage to prevent water ponding.4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=372, 8=372.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 63: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

F3

Truss Type

HIP GIRDER

Qty

1

Ply

3

Job Reference (optional)

T20992422

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:45 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QCqIOZjbKHJ_clHaabh08oAM8Gfi5WjP5Q?ypjyouGa

Scale = 1:46.1

1

2

3

4 5

6

7

8

12 11 10 913 14 15 16 17 18 19 20 21

6x8 5x6

8x14 MT20HS

5x6

3x8 6x8

3x4

3x8 8x14 MT20HS

5x8

5x8

4x10 MT20HS

6x12 MT20HS

4x6

4x6

3x12 MT20HSSpecial

1-2-81-2-8

1-6-80-4-0

6-3-04-8-8

10-11-84-8-8

14-9-83-10-0

19-6-04-8-8

24-2-84-8-8

24-6-80-4-0

25-9-0

1-2-8

1-6-81-6-8

6-3-04-8-8

10-11-84-8-8

14-9-83-10-0

19-6-04-8-8

24-2-84-8-8

25-9-01-6-8

0-6-

3

5-1-

0

0-6-

3

5-1-

0

5.00 12

Plate Offsets (X,Y)-- [1:0-2-9,0-4-8], [1:0-0-2,Edge], [4:0-5-4,0-3-8], [5:0-3-4,0-3-4], [8:1-2-15,0-0-14], [8:0-0-6,0-4-4], [10:0-4-0,0-4-4], [11:0-7-0,0-4-8], [12:0-4-12,0-1-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.640.780.95

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.24

-0.390.12

(loc)11-1211-12

8

l/defl>999>779

n/a

L/d240180n/a

PLATESMT20MT20HS

Weight: 544 lb FT = 20%

GRIP244/190187/143

LUMBER-TOP CHORD 2x6 SP No.2BOT CHORD 2x6 SP M 26WEBS 2x4 SP No.3SLIDER Left 2x6 SP No.2 3-0-0, Right 2x6 SP No.2 3-0-0

BRACING-TOP CHORD Structural wood sheathing directly applied or 4-9-15 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 1=0-8-0, 8=0-8-0Max Horz 1=-146(LC 6)Max Uplift 1=-5212(LC 8), 8=-3645(LC 8)Max Grav 1=12387(LC 1), 8=8879(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-3=-25183/10554, 3-4=-18377/7724, 4-5=-16481/6928, 5-6=-17645/7346,

6-8=-20424/8412BOT CHORD 1-12=-9571/22949, 11-12=-9571/22949, 10-11=-7051/17197, 9-10=-7587/18532,

8-9=-7587/18532WEBS 3-12=-2580/6093, 3-11=-6831/2984, 4-11=-3201/7461, 4-10=-1270/721, 5-10=-2585/6257,

6-10=-2576/1124, 6-9=-1002/2543

NOTES-1) 3-ply truss to be connected together with 10d (0.131"x3") nails as follows:

Top chords connected as follows: 2x6 - 2 rows staggered at 0-9-0 oc.Bottom chords connected as follows: 2x6 - 2 rows staggered at 0-5-0 oc.Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.

2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply toply connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.

3) Unbalanced roof live loads have been considered for this design.4) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.605) Provide adequate drainage to prevent water ponding.6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb)

1=5212, 8=3645.10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 2100 lb down and 966 lb up at

2-5-4, 2132 lb down and 950 lb up at 4-5-4, 2132 lb down and 950 lb up at 6-5-4, 2132 lb down and 950 lb up at 8-5-4, 2132 lbdown and 950 lb up at 10-5-4, 2132 lb down and 950 lb up at 12-5-4, 2132 lb down and 950 lb up at 14-5-4, 1012 lb down and351 lb up at 16-0-4, 1012 lb down and 351 lb up at 18-0-4, and 1685 lb down and 868 lb up at 20-0-4, and 155 lb down and 56 lbup at 22-0-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.

LOAD CASE(S) StandardContinued on page 2

THIS TRUSS IS NOT SYMMETRIC.PROPER ORIENTATION IS ESSENTIAL.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 64: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

F3

Truss Type

HIP GIRDER

Qty

1

Ply

3

Job Reference (optional)

T20992422

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:45 2020 Page 2 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QCqIOZjbKHJ_clHaabh08oAM8Gfi5WjP5Q?ypjyouGa

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-4=-80, 4-5=-80, 5-8=-80, 1-8=-20

Concentrated Loads (lb)Vert: 12=-2132 10=-2132 13=-2100 14=-2132 15=-2132 16=-2132 17=-2132 18=-1012(B) 19=-1012(B) 20=-1685(B) 21=-155

Page 65: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

HJ8

Truss Type

Diagonal Hip Girder

Qty

2

Ply

1

Job Reference (optional)

T20992423

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:47 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-Mby3pFkrsuZir3Qzh0kUDDGm83VsZe0iYkU3ubyouGY

Scale = 1:15.5

1

25

3

6 7

44x6

3x4

3x4

6x8

2-1-132-1-13

7-0-24-10-5

3-5-143-5-14

7-0-23-6-3

0-6-

3

2-7-

0

2-6-

14

2-2-

13 2-7-

0

3.54 12

Plate Offsets (X,Y)-- [1:0-9-13,0-2-0], [1:0-4-0,0-4-2]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.350.160.00

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.03-0.04-0.01

(loc)1-41-4

3

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 37 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2SLIDER Left 2x8 SP 2400F 2.0E 3-2-10

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 3=Mechanical, 4=Mechanical, 1=0-8-0Max Horz 1=117(LC 8)Max Uplift 3=-105(LC 8), 4=-22(LC 5), 1=-187(LC 5)Max Grav 3=138(LC 1), 4=87(LC 3), 1=310(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.602) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)

3=105, 1=187.6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 44 lb down and 120 lb up at

4-2-8, and 44 lb down and 120 lb up at 4-2-8 on top chord, and 62 lb down and 103 lb up at 1-4-9, 62 lb down and 103 lb up at 1-4-9, and 52 lb up at 4-2-8, and 52 lb up at 4-2-8 on bottom chord. The design/selection of such connection device(s) is theresponsibility of others.

7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-3=-80, 1-4=-20

Concentrated Loads (lb)Vert: 5=216(F=108, B=108) 6=-123(F=-62, B=-62) 7=85(F=43, B=43)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 66: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

HJ8A

Truss Type

Diagonal Hip Girder

Qty

2

Ply

1

Job Reference (optional)

T20992424

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:48 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-qnWR0blTcChZTD?9FkFjmQou5TnQI1irnODcQ2youGX

Scale: 3/4"=1'

1

2

6

5

4

3

73x4

3x4

3x4

2x4

4-0-04-0-0

4-2-140-2-14

7-0-22-9-4

3-5-143-5-14

7-0-23-6-3

0-6-

3

2-7-

0

3.54 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.530.330.29

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.010.01

-0.01

(loc)5-65-6

3

l/defl>999>999

n/a

L/d240180n/a

PLATESMT20

Weight: 27 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2WEBS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.

REACTIONS. (size) 3=Mechanical, 5=Mechanical, 6=0-5-11Max Horz 6=122(LC 8)Max Uplift 3=-28(LC 8), 5=-384(LC 1), 6=-745(LC 8)Max Grav 3=50(LC 13), 5=228(LC 8), 6=1217(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 1-2=-452/777BOT CHORD 1-6=-670/453, 5-6=-670/332WEBS 2-5=-379/767, 2-6=-1043/644

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.602) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3 except (jt=lb)

5=384, 6=745.6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 172 lb down and 297 lb up at

4-2-8, and 44 lb down and 120 lb up at 4-2-8 on top chord, and 62 lb down and 103 lb up at 1-4-9, and 62 lb down and 103 lb up at 1-4-9 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.

7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-3=-80, 1-4=-20

Concentrated Loads (lb)Vert: 2=-64(F=-172, B=108) 7=-123(F=-62, B=-62)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 67: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

HJ10

Truss Type

DIAGONAL HIP GIRDER

Qty

5

Ply

1

Job Reference (optional)

T20992425

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:45 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-QCqIOZjbKHJ_clHaabh08oAKnGih5jQP5Q?ypjyouGa

Scale = 1:19.3

1

2

3

6

7

8

4

9 10 11 5

2x4

2x4

4x6

3x4

3x4

6x8

2-1-132-1-13

9-10-17-8-4

2-1-132-1-13

7-7-55-5-8

9-10-12-2-12

0-6-

3

3-5-

0

3.54 12

Plate Offsets (X,Y)-- [1:0-9-13,0-2-0], [1:0-3-8,0-3-15]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.720.590.07

DEFL.Vert(LL)Vert(CT)Horz(CT)

in0.20

-0.21-0.01

(loc)1-61-6

4

l/defl>565>532

n/a

L/d240180n/a

PLATESMT20

Weight: 56 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x6 SP No.2WEBS 2x4 SP No.3SLIDER Left 2x8 SP 2400F 2.0E 4-8-14

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 4=Mechanical, 5=Mechanical, 1=0-8-0Max Horz 1=162(LC 8)Max Uplift 4=-52(LC 8), 5=-165(LC 4), 1=-232(LC 5)Max Grav 4=105(LC 1), 5=248(LC 1), 1=401(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.602) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 4 except (jt=lb)

5=165, 1=232.6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 123 lb up at

4-2-8, 38 lb down and 123 lb up at 4-2-8, and 146 lb up at 7-0-7, and 148 lb up at 7-0-7 on top chord, and 62 lb down and 93 lb upat 1-4-9, 62 lb down and 93 lb up at 1-4-9, 52 lb up at 4-2-8, 52 lb up at 4-2-8, and 15 lb up at 7-0-7, and 7 lb down and 33 lb upat 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.

7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-4=-80, 1-5=-20

Concentrated Loads (lb)Vert: 7=216(F=108, B=108) 8=15(F=7, B=8) 9=-123(F=-62, B=-62) 10=85(F=43, B=43) 11=-3(F=-7, B=4)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 68: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

HJ10A

Truss Type

Diagonal Hip Girder

Qty

1

Ply

1Job Reference (optional)

T20992426

Run: 8.240 s Mar 9 2020 Print: 8.240 s Jun 26 2020 MiTek Industries, Inc. Tue Aug 11 16:33:19 2020 Page 1 ID:EUbcdRdSVPjz3PsjTVS_RMzJaSG-FWIWH_Tml7LTu7rvq2SwOnR81_uBZzoAA6CGZCyotdk

Scale = 1:19.5

17

4

65

8

9

2

10 11 3

2x4

2x4 12x14 3x4

3x8

2-1-132-1-13

3-7-151-6-2

6-10-03-2-1

9-9-112-11-11

9-10-10-0-6

2-1-132-1-13

3-6-91-4-13

9-9-116-3-1

9-10-10-0-6

0-6-

3

3-5-

0

2-5-

0

1-0-

0

3.54 12

Plate Offsets (X,Y)-- [1:1-6-14,0-5-9], [1:0-3-4,0-8-5], [1:1-0-13,0-0-0], [7:1-6-10,0-2-8], [7:0-1-11,0-0-8]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25NO

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.340.470.05

DEFL.Vert(LL)Vert(CT)Horz(CT)

in-0.29-0.520.03

(loc)553

l/defl>331>184

n/a

L/d240180n/a

PLATESMT20

Weight: 50 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP M 31BOT CHORD 2x4 SP M 31 *Except*

1-5: 2x6 SP M 26WEBS 2x4 SP No.3WEDGELeft: 2x8 SP 2400F 2.0E

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:

6-0-0 oc bracing: 1-7.

REACTIONS. (lb/size) 2=214/Mechanical, 3=107/Mechanical, 1=374/0-8-0Max Horz 1=127(LC 8)Max Uplift 2=-137(LC 4), 1=-189(LC 5)Max Grav 2=214(LC 1), 3=193(LC 3), 1=374(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=5ft;

Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); cantilever left exposed ; Lumber DOL=1.60 plate grip DOL=1.602) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.4) Refer to girder(s) for truss to truss connections.5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 137 lb uplift at joint 2 and 189 lb uplift

at joint 1.6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 38 lb down and 123 lb up at

4-2-8, 38 lb down and 123 lb up at 4-2-8, and 8 lb down and 122 lb up at 7-0-7, and 8 lb down and 122 lb up at 7-0-7 on topchord, and 62 lb down and 93 lb up at 1-4-9, 62 lb down and 93 lb up at 1-4-9, 52 lb up at 4-2-8, 52 lb up at 4-2-8, and 9 lb downand 14 lb up at 6-10-0, and 9 lb down and 14 lb up at 6-10-0 on bottom chord. The design/selection of such connection device(s)is the responsibility of others.

7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).

LOAD CASE(S) Standard1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25

Uniform Loads (plf)Vert: 1-2=-80, 3-5=-20

Concentrated Loads (lb)Vert: 5=-19(F=-9, B=-9) 1=-123(F=-62, B=-62) 8=216(F=108, B=108) 9=49(F=24, B=24) 10=85(F=43, B=43)

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 69: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

V6

Truss Type

Valley

Qty

1

Ply

1

Job Reference (optional)

T20992427

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:53 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:lKtZudpUoLXvUWdei_VjLRy9R5D-BlJK3IpcRkKrZ_u62HquTUWr8Ua0zMhbwgxN6FyouGS

Scale = 1:11.1

1

2

3

4

2x4

4x6

2x4 2x4

0-0-100-0-10

6-0-05-11-6

3-0-03-0-0

6-0-03-0-0

0-0-

4

1-3-

0

0-0-

4

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-P

0.120.050.05

DEFL.Vert(LL)Vert(CT)Horz(CT)

inn/an/a

0.00

(loc) - - 3

l/defln/an/an/a

L/d999999n/a

PLATESMT20

Weight: 17 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2OTHERS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 1=5-10-13, 3=5-10-13, 4=5-10-13Max Horz 1=-30(LC 10)Max Uplift 1=-44(LC 12), 3=-44(LC 12), 4=-45(LC 12)Max Grav 1=113(LC 1), 3=113(LC 1), 4=224(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactionsshown; Lumber DOL=1.60 plate grip DOL=1.60

3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 70: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

V10

Truss Type

Valley

Qty

1

Ply

1

Job Reference (optional)

T20992428

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:49 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:lKtZudpUoLXvUWdei_VjLRy9R5D-Iz4pDwm6NVpQ4NaLpRmyIeL7QtAv1XF??2zAyUyouGW

Scale: 3/4"=1'

1

2

3

4

5

67

8

2x4

4x6

2x4 2x4

0-0-100-0-10

10-0-09-11-6

5-0-05-0-0

10-0-05-0-0

0-0-

4

2-1-

0

0-0-

4

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.300.190.08

DEFL.Vert(LL)Vert(CT)Horz(CT)

inn/an/a

0.00

(loc) - - 3

l/defln/an/an/a

L/d999999n/a

PLATESMT20

Weight: 31 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2OTHERS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 1=9-10-13, 3=9-10-13, 4=9-10-13Max Horz 1=-56(LC 10)Max Uplift 1=-67(LC 12), 3=-67(LC 12), 4=-118(LC 12)Max Grav 1=192(LC 21), 3=192(LC 22), 4=472(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 2-4=-340/272

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 5-0-0, Exterior(2) 5-0-0 to8-0-0, Interior(1) 8-0-0 to 9-2-15 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60

3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb)

4=118.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 71: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

V14

Truss Type

GABLE

Qty

1

Ply

1

Job Reference (optional)

T20992429

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:50 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:lKtZudpUoLXvUWdei_VjLRy9R5D-mAeBRGnk8pxHiW9YM9HBrruC_HSim_48EiijVwyouGV

Scale = 1:22.4

1

2

3

4

5

6

3x4

5x6

3x4 2x4

14-0-014-0-0

7-0-07-0-0

14-0-07-0-0

0-0-

4

2-11

-0

0-0-

4

5.00 12

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.690.410.11

DEFL.Vert(LL)Vert(CT)Horz(CT)

inn/an/a

0.00

(loc) - - 3

l/defln/an/an/a

L/d999999n/a

PLATESMT20

Weight: 44 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2OTHERS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. (size) 1=14-0-0, 3=14-0-0, 4=14-0-0Max Horz 1=-83(LC 10)Max Uplift 1=-99(LC 12), 3=-99(LC 12), 4=-173(LC 12)Max Grav 1=282(LC 21), 3=282(LC 22), 4=694(LC 1)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 2-4=-501/333

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 7-0-0, Exterior(2) 7-0-0 to10-0-0, Interior(1) 10-0-0 to 13-2-15 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60

3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb)

4=173.

This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 72: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

V18

Truss Type

Valley

Qty

1

Ply

1

Job Reference (optional)

T20992430

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:51 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:lKtZudpUoLXvUWdei_VjLRy9R5D-FMCZecnMv738KgkkwsoQN3QR?grjVRWITMSH1NyouGU

Scale = 1:28.7

1

2

3

4

5

8 7 6

910

3x4

4x6

3x4 5x6 2x4

2x4

2x4

2x4

0-0-100-0-10

18-0-017-11-6

9-0-09-0-0

18-0-09-0-0

0-0-

4

3-9-

0

0-0-

4

5.00 12

Plate Offsets (X,Y)-- [7:0-3-0,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.420.230.10

DEFL.Vert(LL)Vert(CT)Horz(CT)

inn/an/a

0.00

(loc) - - 5

l/defln/an/an/a

L/d999999n/a

PLATESMT20

Weight: 64 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2OTHERS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. All bearings 17-10-13.(lb) - Max Horz 1=-109(LC 10)

Max Uplift All uplift 100 lb or less at joint(s) 1, 5 except 6=-215(LC 12), 8=-216(LC 12)Max Grav All reactions 250 lb or less at joint(s) 1, 5, 7 except 6=561(LC 18), 8=561(LC 17)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 4-6=-431/320, 2-8=-431/320

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 9-0-0, Exterior(2) 9-0-0 to12-0-0, Interior(1) 12-0-0 to 17-2-15 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60

3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5 except (jt=lb)

6=215, 8=216.This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 73: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component

available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601Safety Information

WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.

6904 Parke East Blvd.Tampa, FL 36610

Job

2221_M_160_C_3-CAR

Truss

V22

Truss Type

Valley

Qty

1

Ply

1

Job Reference (optional)

T20992431

8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Aug 11 14:49:52 2020 Page 1 Builders FirstSource, Punta Gorda, FL - 33950,ID:lKtZudpUoLXvUWdei_VjLRy9R5D-jYlysyo_gQC?xqJwUZJfwGzbx4BsEuPRi0BqZpyouGT

Scale = 1:35.1

1

2

3

4

5

8 7 6

9

10 11

12

3x4

4x6

3x4

5x6 2x4

2x4

2x4

2x4

0-0-100-0-10

22-0-021-11-6

11-0-011-0-0

22-0-011-0-0

0-0-

4

4-7-

0

0-0-

4

5.00 12

Plate Offsets (X,Y)-- [7:0-3-0,0-3-0]

LOADING (psf)TCLLTCDLBCLLBCDL

20.020.0

0.0 *10.0

SPACING-Plate Grip DOLLumber DOL Rep Stress IncrCode

2-0-01.251.25YES

FBC2017/TPI2014

CSI.TCBCWBMatrix-S

0.470.240.12

DEFL.Vert(LL)Vert(CT)Horz(CT)

inn/an/a

0.00

(loc) - - 5

l/defln/an/an/a

L/d999999n/a

PLATESMT20

Weight: 77 lb FT = 20%

GRIP244/190

LUMBER-TOP CHORD 2x4 SP No.2BOT CHORD 2x4 SP No.2OTHERS 2x4 SP No.3

BRACING-TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.

REACTIONS. All bearings 21-10-13.(lb) - Max Horz 1=136(LC 11)

Max Uplift All uplift 100 lb or less at joint(s) 1, 5, 7 except 6=-242(LC 12), 8=-243(LC 12)Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=398(LC 1), 6=623(LC 18), 8=621(LC 17)

FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.WEBS 3-7=-314/111, 4-6=-491/345, 2-8=-492/345

NOTES-1) Unbalanced roof live loads have been considered for this design.2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=6.0psf; BCDL=6.0psf; h=15ft; B=45ft; L=24ft; eave=4ft; Cat.

II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) 0-9-1 to 3-9-1, Interior(1) 3-9-1 to 11-0-0, Exterior(2) 11-0-0 to14-0-0, Interior(1) 14-0-0 to 21-2-15 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60

3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.5) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide

will fit between the bottom chord and any other members.6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except

(jt=lb) 6=242, 8=243.This item has beenelectronically signed andsealed by Albani, Thomas, PEusing a Digital Signature.Printed copies of thisdocument are not consideredsigned and sealed and thesignature must be verified on any electronic copies.

August 11,2020

Page 74: City of s v ]...10'-4"Tray 10'-4"Tray 10'-4"Tray 10'-4"Tray EXPOSEDTOWIND EXPOSEDTOWIND U:2263 U:1335 U:1152 R:12,387 U:5212 R:8879 U:3645 U:1097 U:1097 A A A A A A A A A A A* B A01

PR

OD

UC

T C

OD

E A

PP

RO

VA

LS

LA

TE

RA

L B

RA

CIN

G L

OC

AT

ION

Indicates location where bearings

(supports) occur. Icons vary butreaction section indicates jointnum

ber where bearings occur.

Min size show

n is for crushing only.

Indicated by symbol show

n and/orby text in the bracing section of theoutput. U

se T or I bracing

if indicated.

The first dim

ension is the plate w

idth measured perpendicular

to slots. Second dim

ension isthe length parallel to slots.

Center plate on joint unless x, y

offsets are indicated.D

imensions are in ft-in-sixteenths.

Apply plates to both sides of truss

and fully embed teeth.

1. Additional stability bracing for truss system

, e.g. diagonal or X

-bracing, is always required. S

ee BC

SI.

2. Truss bracing m

ust be designed by an engineer. For

wide truss spacing, individual lateral braces them

selves m

ay require bracing, or alternative Tor I

bracing should be considered.

3. Never exceed the design loading show

n and never stack m

aterials on inadequately braced trusses.

4. Provide copies of this truss design to the building

designer, erection supervisor, property owner and

all other interested parties.

5. Cut m

embers to bear tightly against each other.

6. Place plates on each face of truss at each

joint and embed fully. K

nots and wane at joint

locations are regulated by AN

SI/T

PI 1.

7. Design assum

es trusses will be suitably protected from

the environment in accord w

ith AN

SI/T

PI 1.

8. Unless otherw

ise noted, moisture content of lum

ber shall not exceed 19%

at time of fabrication.

9. Unless expressly noted, this design is not applicable for

use with fire retardant, preservative treated, or green lum

ber.

10. Cam

ber is a non-structural consideration and is the responsibility of truss fabricator. G

eneral practice is to cam

ber for dead load deflection.

11. Plate type, size, orientation and location dim

ensions indicated are m

inimum

plating requirements.

12. Lumber used shall be of the species and size, and

in all respects, equal to or better than that specified.

13. Top chords m

ust be sheathed or purlins provided at spacing indicated on design.

14. Bottom

chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherw

ise noted.

15. Connections not show

n are the responsibility of others.

16. Do not cut or alter truss m

ember or plate w

ithout prior approval of an engineer.

17. Install and load vertically unless indicated otherwise.

18. Use of green or treated lum

ber may pose unacceptable

environmental, health or perform

ance risks. Consult w

ith project engineer before use.

19. Review

all portions of this design (front, back, words

and pictures) before use. Review

ing pictures alone is not sufficient.

20. Design assum

es manufacture in accordance w

ith A

NS

I/TP

I 1 Quality C

riteria.

21.The design does not take into account any dynam

ic or other loads other than those expressly stated.

Failure to F

ollow C

ould Cause P

ropertyD

amage or P

ersonal Injury

(Draw

ings not to scale)

© 2012 M

iTek®

All R

ights Reserved

MiT

ek Engineering R

eference Sheet: M

II-7473 rev. 5/19/2020

edge of truss. from outside

" 16/ 1

-0

ICC

-ES

Reports:

ES

R-1311, E

SR

-1352, ES

R1988

ER

-3907, ES

R-2362, E

SR

-1397, ES

R-3282

JOIN

TS

AR

E G

EN

ER

AL

LY

NU

MB

ER

ED

/LE

TT

ER

ED

CL

OC

KW

ISE

AR

OU

ND

TH

E T

RU

SS

ST

AR

TIN

G A

T T

HE

JOIN

T F

AR

TH

ES

T T

OT

HE

LE

FT

.

CH

OR

DS

AN

D W

EB

S A

RE

IDE

NT

IFIE

D B

Y E

ND

JOIN

TN

UM

BE

RS

/LE

TT

ER

S.

W4-6

W3-6

W3-7

W2-7

W1-7

C1-8

C5-6

C6-7

C7-8

C4-5

C3-4

C2-3

C1-2

TOP CHORD

TOP CHORD87

65 4

32

1

BO

TT

OM

CH

OR

DS

TO

P C

HO

RD

S

BE

AR

ING

4 x 4

PL

AT

E S

IZE

This sym

bol indicates the required direction of slots inconnector plates.

"16

/ 1

For 4 x 2 orientation, locate

plates 0-

1"4 / 3

PL

AT

E L

OC

AT

ION

AN

D O

RIE

NT

AT

ION

Sym

bo

lsN

um

berin

g S

ystemG

eneral S

afety No

tes

*P

late locatio

n d

etails available in

MiT

ek 20/20so

ftware o

r up

on

requ

est.

Ind

ustry S

tand

ards:

AN

SI/T

PI1: N

ational Design S

pecification for Metal

Plate C

onnected Wood T

russ Construction.

DS

B-89: D

esign Standard for B

racing.B

CS

I: Building C

omponent S

afety Information,

Guide to G

ood Practice for H

andling, Installing &

Bracing of M

etal Plate

Connected W

ood Trusses.

6-4-8

WE

BS

Trusses are designed for w

ind loads in the plane of the truss unless otherw

ise shown.

Lumber design values are in accordance w

ith AN

SI/T

PI 1

section 6.3 These truss designs rely on lum

ber values established by others. d

imen

sion

s sho

wn

in ft-in

-sixteenth

s