Clock Domain Crossing (CDC)
Erik Seligman
CS 510, Lecture 17, March 2009
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
What Is A Clock Domain Crossing (CDC)? Different clocks within a single design Many possible reasons, here are a few:
• Complying with multiple protocols
• SoC Integration: IP from many sources
• Saving area/power, limiting fast clock use
Dangers when signals cross domains• Incorrect functionality if not synced
• Not properly covered by validation
Review: Setup & Hold Time
Each flop has a setup and hold time• Setup time: Time before clk edge
• Hold time: Time after clk edge
Data expected ready by setup time, and stable during hold time
Problems At Asynchronous Clock Domain Crossings When does new value arrive?
• Source clk not coordinated with dest clk
Chance of arriving in setup/hold window
• What does this mean?• Possibility of ‘metastable’ (halfway) state
• Value may settle either way
• Multiple fanouts may detect different values
Why Discuss in FV Class?
CDC is low hanging fruit for FV vendor• Needs deeper analysis than typical linting
• But light checks compared to hardcore FV
CDC often done with FV tools• Mentor 0in, Cadence Conformal, RealIntent
– In other direction, Lint vendors expanding to CDC: Synopsys LEDA, Atrenta Spyglass
Some CDC checks may add assertions• For checking in simulation or FV
CDC Checks in Simulation
Simulation: inject random metastability Useful, but hard to get right
• Sometimes delay a value change
• Allow 1-cycle value to be missed
• Depends on # of random tests
Technique beyond scope of this class• Class is on formal methods!
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
How To Safely Cross Domains? Require synchronizer: structure to
reduce risk of metastability Simplest synchronizer: two flops
• Metastability very unlikely: second flop will choose a value if first is metastable
• One-cycle uncertainty in transition– Account for in the logic!
Basic CDC Checks
Structural: Identify asynchronous CDCs• Note: synchronous signals are OK, little metastability
risk if properly timed
• But same-frequency != synchronous
• If no synchronizer, report error
Functional: Assert signal held long enough• Due to uncertainty of capture time
• Hold for 2+ receiver cycles: create assert
• May need longer depending on relative freq– More detailed discussion in TOV lecture
Another Check: Combo Logic
• Why is combo logic bad on sync path?
Another Check: Combo Logic
• Why is combo logic bad on sync path?• Remember: uncertain capture time• Suppose f1a and f1b both transition 01
Another Check: Combo Logic
• Why is combo logic bad on sync path?• Remember: uncertain capture time• Suppose f1a and f1b both transition 01• For an instant, maybe f1a!=f1b…
f2 == 1
Danger: False Negatives!
CDC can be a ‘noisy’ check• Many reported unsynced crossings are OK
Common reasons for false negatives?
Danger: False Negatives! CDC can be a ‘noisy’ check
• Many reported unsynced crossings are OK Common reasons for false negatives?
• Constant signals (VSS, VCC)• Near-constant signals
– Parameters set during reset & never changed– Reset pins!
• Alternate-mode signals– Valid in only some operating modes, includes clk– Scan and other ultra-slow interfaces
Use your tool carefully & specify these things!• “Blind” run rarely seen as valuable• Don’t waste DE time reporting bogus errors
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
Datapaths & Off-By-One Issue
• What happens on transition from 000 to 111?
Datapath Problem
Each synchronizer may be off by a cycle• All are independent
• So during transition from 000 to 111, may sense 001, 010, 011, … or any other value!
Can we solve thru logic requirements?• Need to make sure only one bit can change
• Then we know only real values are seen
Grey Codes: A Functional Solution
Common solution to datapath issue• Allow only one bit to change at a time
• Thus, any value seen *did* actually appear
• From 000, can only go to: 100,010,001– And if the bit changes a cycle soon/late, only a
real value is seen
2-bit grey codes example: 00,01,11,10 Can check with generated assertions
• Functional (FPV-like) check in general
SVA Assertion: Grey Code
“Signal foo[6:0] is grey-coded”• Can you translate to SVA?
SVA Assertion: Grey Code
“Signal foo[6:0] is grey-coded”• Can you translate to SVA?
gc_assert: assert property (
$countones(foo ^ $past(foo)) <= 1);
Reconvergence Problem
More general view of datapath issue Problem: reconvergence of synced bits
• CDC checks can flag cases
Is there a better way to synchronize?• Such that grey codes aren’t needed
Yes!• Have control signal coordinate data with mux
Mux-Based Sync
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
Handshake/FIFO Protocols
Clock freq maybe configurable / unknown• Hard to design previous syncs for all cases
• Hard to properly check for all cases
• Maybe sometimes overconservative
Solution: handshake protocols• Sender stores data in FIFO
• Explicit request/response for data
• More logic & harder to check, but powerful
Handshake Sync Example
(From Cadence white paper, see References)
Agenda
Introduction to Clock Domain Crossing (CDC)
Basic Synchronizers Datapaths and Reconvergence Handshake Synchronization Checking CDCs With Conformal
Conformal CDC Checks
Included with Conformal license• That’s why we have it!
Set up env for Conformal version 8• zsh
• source ~eseligma/startup.cadence8
Start lec with ‘-verify’ option• Actually runs separate core binary
• Don’t try to do FEV in same session
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase -extract
add synchronization rule dff_sync -dff 2 infinity -sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination -all -from -all -to -all
validate
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase –
extractadd clock 0 clk1add clock 0 clk2set sys mode verifyadd synchronization rule dff_sync -dff 2 infinity -
sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination
-all -from -all -to -allvalidate
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase –
extractadd clock 0 clk1add clock 0 clk2set sys mode verifyadd synchronization rule dff_sync -dff 2 infinity -
sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination
-all -from -all -to -allvalidate
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase –
extractadd clock 0 clk1add clock 0 clk2set sys mode verifyadd synchronization rule dff_sync -dff 2 infinity -
sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination
-all -from -all -to -allvalidate
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase –
extractadd clock 0 clk1add clock 0 clk2set sys mode verifyadd synchronization rule dff_sync -dff 2 infinity -
sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination
-all -from -all -to -allvalidate
Sample LEC CDC Do File(Structural Checks)read design <RTL design> set clock_domain rule -derived -either_phase –
extractadd clock 0 clk1add clock 0 clk2set sys mode verifyadd synchronization rule dff_sync -dff 2 infinity -
sync_chain buffer -cdc_path buffer single_destination -from -all -to -all
add synchronization rule all2allmux2 -mux 0 0 -cdc_path buffer single_destination -from -all -to -all
set cdc option -convergence_checkadd cdc check -structural -source -all -destination
-all -from -all -to -allvalidate
Debugging with Tools Menu: Clock Domain Crossing
Diagnosing A Missing Sync
Diagnosing A Convergence Issue
References / Further Reading
http://www.edadesignline.com/howto/205201913;jsessionid=Y5OIFHG055FBKQSNDLPSKHSCJUNN2JVN?pgno=1
http://w2.cadence.com/whitepapers/cdc_wp.pdf
http://www.techonline.com/article/pdf/showPDFinIE.jhtml?id=2069034541
http://www.design-reuse.com/articles/9482/reducing-false-errors-in-clock-domain-crossing-analysis.html