2
Cladding Roll Products Thermal and acoustic insulation for walls and roofs of industrial type buildings DESCRIPTION Isover Cladding Roll is a high quality lightweight thermal and acoustic glass mineral wool insulation product. It provides a strong, resilient and flexible insulating medium, which is easy to handle, cut and install. STANDARDS Cladding Roll products are manufactured under BSI Quality Management Standard BS EN ISO 9001:2000. BENEFITS Excellent thermal and acoustic performance Totally non-combustible (Euroclass A1) • Easy to install Long product life – performance will not deteriorate with age Exceptional tear strength – will support its own weight in vertical drops Durable – not easily damaged in storage, during transport or onsite when installed Does not absorb water FIRE PERFORMANCE Completely fire safe – Euroclass A1 fire rating when classified in accordance with BS EN 13501-1. ENVIRONMENTAL INFORMATION Isover glass mineral wool insulation is manufactured from a combination of silica sand and up to 80% recycled post-consumer glass from building regeneration projects or flat glass manufacture that would otherwise go to landfill. This makes Isover one of the most environmentally sustainable insulation products on the market today. The material credentials of installing Isover glass mineral wool insulation include: BRE GREEN GUIDE SPECIFICATION Product rating: Glass mineral wool insulation products have a ‘best-in-class’ A+ rating (via generic listing). Construction rating: Built up twin skin metal wall & roof constructions typically have A+ or A element ratings under the BRE Green Guide 2008. BREEAM: Education 2008 Isover Cladding Roll can assist in gaining credit under category HEA 13 of BREEAM:Education 2008 by helping to improve the acoustic performance of the external envelope. The requirement is that internal ambient noise levels during ‘heavy’ rainfall does not exceed the levels defined in table 1.1 of Building Bulletin 93 by more than 20dB. Certificate number: FM 01032 • Zero ODP (Ozone Depletion Potential) • Zero GWP (Global Warming Potential) The World’s Leading Acoustic and Thermal Insulation Ref: CR001 January 2009 Cl/Sfb (Km1) (M2)

Cl/Sfb (Km1) (M2) Cladding Roll Products - Encon Insulation · Cladding Roll Products ... Isover Cladding Roll is a high quality lightweight thermal and acoustic glass mineral wool

  • Upload
    ngodang

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Cladding Roll ProductsThermal and acoustic insulation for walls and roofs of industrial type buildings

DESCRIPTIONIsover Cladding Roll is a high quality lightweight thermal and acoustic glass mineral wool insulation product.

It provides a strong, resilient and fl exible insulating medium, which is easy to handle, cut and install.

STANDARDSCladding Roll products are manufactured under BSI Quality Management Standard BS EN ISO 9001:2000.

BENEFITS• Excellent thermal and acoustic performance

• Totally non-combustible (Euroclass A1)

• Easy to install

• Long product life – performance will not deteriorate with age

• Exceptional tear strength – will support its own weight in vertical drops

• Durable – not easily damaged in storage, during transport or onsite when installed

• Does not absorb water

FIRE PERFORMANCECompletely fi re safe – Euroclass A1 fi re rating when classifi ed in accordance with BS EN 13501-1.

ENVIRONMENTAL INFORMATIONIsover glass mineral wool insulation is manufactured from a combination of silica sand and up to 80% recycled post-consumer glass from building regeneration projects or fl at glass manufacture that would otherwise go to landfi ll. This makes Isover one of the most environmentally sustainable insulation products on the market today. The material credentials of installing Isover glass mineral wool insulation include:

BRE GREEN GUIDE SPECIFICATIONProduct rating: Glass mineral wool insulation products have a ‘best-in-class’ A+ rating (via generic listing).

Construction rating: Built up twin skin metal wall & roof constructions typically have A+ or A element ratings under the BRE Green Guide 2008.

BREEAM: Education 2008

Isover Cladding Roll can assist in gaining credit under category HEA 13 of BREEAM:Education 2008 by helping to improve the acoustic performance of the external envelope. The requirement is that internal ambient noise levels during ‘heavy’ rainfall does not exceed the levels defi ned in table 1.1 of Building Bulletin 93 by more than 20dB.

Certifi cate number: FM 01032

• Zero ODP (Ozone Depletion Potential)

• Zero GWP (Global Warming Potential)

The World’s Leading Acoustic and Thermal Insulation

Ref: CR001 January 2009

Cl/Sfb (Km1) (M2)

BUILDING REGULATIONS COMPLIANCEEngland and Wales – Part L2A 2006 – Building fabric must contribute to a 23.5% or 28% (depending on building services strategy for the building) reduction in CO

2 emissions when compared with 2002

requirements. Under the SBEM calculations, the U-value will depend upon the balance of other measures including building services and window specifi cations. However there are limiting U-Values as per table:

Element Area-weighted average (W/m2.K)

For any individual element (W/m2.K)

Wall 0.35 0.70Roof 0.25 0.35

Cladding Roll 40 - Roof Rail Spacing (mm)

Insulation thickness (mm) 1200 1800 240060 0.77 0.73 0.7080 0.56 0.53 0.52100 0.44 0.43 0.42120 0.37 0.36 0.35140 0.32 0.31 0.30160 0.28 0.27 0.27180 0.25 0.24 0.24200 0.23 0.22 0.21

Cladding Roll 40 - Wall Rail Spacing (mm)

Insulation thickness (mm) 1200 1800 240060 0.75 0.71 0.6980 0.55 0.53 0.51100 0.44 0.42 0.41120 0.37 0.35 0.35140 0.31 0.30 0.30160 0.28 0.27 0.26180 0.25 0.24 0.24200 0.22 0.22 0.21

THERMAL PERFORMANCEThermal Conductivity (Lambda Value)Cladding Roll 40 0.040 W/m.K; Cladding Roll 37 0.037 W/m.K

PACKAGING AND PHYSICAL DIMENSIONSCladding insulation is manufactured in roll form. The rolls are compression packed in individual packs using a strong polythene packaging fi lm. The packs are then stacked on wooden pallets with fi nal weatherproof outer covering, giving the option of outside storage.

Cladding Roll 40R-value

(m2W/K)Thickness

(mm)Width (mm)

Length (m) Pack Area (m2)

1.50 60 1200 Coming soon2.00 80 1200 Coming soon2.50 100 1200 8.20 9.843.00 120 1200 6.80 8.163.50 140 1200 Coming soon4.00 160 1200 Coming soon4.50 180 1200 4.50 5.405.00 200 1200 4.10 4.92

Cladding Roll 37R-value

(m2W/K)Thickness

(mm)Width (mm)

Length (m) Pack Area (m2)

2.70 100 1200 6.10 7.323.24 120 1200 5.05 6.064.86 180 1200 3.40 4.085.41 200 1200 3.00 3.60

Saint-Gobain IsoverUnit 7Gotham Business ParkLeake RoadGothamNottinghamshire NG11 0LBTel: +44 (0) 115 969 8010Fax: +44 (0) 115 983 1675www.isover.co.uk

Calculated in accordance with SCI P312 Metal Cladding Information Sheet 2002

Technical Support: 0115 945 1143 or E-mail [email protected] Isover reserve the right to alter or amend product specifi cation without notice. The information given in this

publication is correct to the best of our knowledge at the time of publication. Whilst Saint-Gobain Isover will endevourto ensure publications are up to date, it is the users responsibility to check with us that it is correct prior to use.

Cladding Roll 37 - Roof Rail Spacing (mm)

Insulation thickness (mm) 1200 1800 2400100 0.41 0.40 0.39120 0.35 0.33 0.33180 0.23 0.23 0.22200 0.21 0.20 0.20

Cladding Roll 37 - Wall Rail Spacing (mm)

Insulation thickness (mm) 1200 1800 2400100 0.41 0.39 0.39120 0.34 0.33 0.32180 0.23 0.22 0.22200 0.21 0.20 0.20

U-Values (W/m2K)