Form Number ROT 030 Rev 4 1-05 COMPRESSOR DATA SHEET Rotary Screw Compressor MODEL DATA - FOR COMPRESSED AIR 1 Manufacturer: Quincy Compressor Date: 01/01/2009 Model Number: QGD-20-100 Air-cooled Water-cooled # of Stages: 1 2 Oil-injected Oil-free VALUE UNIT 3 Rated Capacity at Full Load Operating Pressure a, f 89.6 acfm a,f 4 Full Load Operating Pressure b 100 psig b 5 Maximum Full Flow Operating Pressure c 115 psig c 6 Drive Motor Nameplate Rating 20 hp 7 Drive Motor Nameplate Nominal Efficiency 90.2 percent 8 Fan Motor Nameplate Rating (if applicable) 1 hp 9 Fan Motor Nameplate Nominal Efficiency 75.5 percent 10 Total Package Input Power at Zero Flow e 6.49 kW e 11 Total Package Input Power at Rated Capacity and Full Load Operating Pressure d 18.6 kW d 12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressure g 20.8 kW/100 cfm g NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows: Volume Flow Rate at specified conditions Volume Flow Rate f Specific Energy Consumption g m 3 / min ft 3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5 This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data. Member

COMPRESSOR DATA SHEET Rotary Screw Compressor

  • Upload
    others

  • View
    149

  • Download
    1

Embed Size (px)

Citation preview

Page 1: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-20-100 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 89.6 acfma,f

4 Full Load Operating Pressure b 100 psigb

5 Maximum Full Flow Operating Pressure c 115 psigc

6 Drive Motor Nameplate Rating 20 hp

7 Drive Motor Nameplate Nominal Efficiency 90.2 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 6.49 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

18.6 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 20.8 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 2: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-20-110 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 89.4 acfma,f

4 Full Load Operating Pressure b 110 psigb

5 Maximum Full Flow Operating Pressure c 125 psigc

6 Drive Motor Nameplate Rating 20 hp

7 Drive Motor Nameplate Nominal Efficiency 90.2 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 6.49 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

20.1 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 22.4 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 3: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-20-125 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 88.2 acfma,f

4 Full Load Operating Pressure b 125 psigb

5 Maximum Full Flow Operating Pressure c 140 psigc

6 Drive Motor Nameplate Rating 20 hp

7 Drive Motor Nameplate Nominal Efficiency 90.2 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 6.49 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

21.5 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 24.4 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 4: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-25-100 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 118 acfma,f

4 Full Load Operating Pressure b 100 psigb

5 Maximum Full Flow Operating Pressure c 115 psigc

6 Drive Motor Nameplate Rating 25 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 7.39 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

23.2 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 19.6 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 5: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-25-110 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 117 acfma,f

4 Full Load Operating Pressure b 110 psigb

5 Maximum Full Flow Operating Pressure c 125 psigc

6 Drive Motor Nameplate Rating 25 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 6.99 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

24.4 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 20.9 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 6: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-25-125 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 115 acfma,f

4 Full Load Operating Pressure b 125 psigb

5 Maximum Full Flow Operating Pressure c 140 psigc

6 Drive Motor Nameplate Rating 25 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 6.99 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

25.8 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 22.4 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 7: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-25-150 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 87.5 acfma,f

4 Full Load Operating Pressure b 150 psigb

5 Maximum Full Flow Operating Pressure c 160 psigc

6 Drive Motor Nameplate Rating 25 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 7.59 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

23.7 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 27.1 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 8: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-30-100 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 138.5 acfma,f

4 Full Load Operating Pressure b 100 psigb

5 Maximum Full Flow Operating Pressure c 115 psigc

6 Drive Motor Nameplate Rating 30 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.39 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

26.5 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 19.1 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 9: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-30-110 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 136.4 acfma,f

4 Full Load Operating Pressure b 110 psigb

5 Maximum Full Flow Operating Pressure c 125 psigc

6 Drive Motor Nameplate Rating 30 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.29 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

27.7 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 20.3 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 10: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-30-125 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 134.9 acfma,f

4 Full Load Operating Pressure b 125 psigb

5 Maximum Full Flow Operating Pressure c 140 psigc

6 Drive Motor Nameplate Rating 30 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.29 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

29.4 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 21.8 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 11: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-30-150 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 117.4 acfma,f

4 Full Load Operating Pressure b 150 psigb

5 Maximum Full Flow Operating Pressure c 160 psigc

6 Drive Motor Nameplate Rating 30 hp

7 Drive Motor Nameplate Nominal Efficiency 91 percent

8 Fan Motor Nameplate Rating (if applicable) 1 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.29 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

28.7 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 24.5 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 12: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-40-100 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 188.8 acfma,f

4 Full Load Operating Pressure b 100 psigb

5 Maximum Full Flow Operating Pressure c 115 psigc

6 Drive Motor Nameplate Rating 40 hp

7 Drive Motor Nameplate Nominal Efficiency 91.7 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.75 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

34.9 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 21.5 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 13: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-40-110 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 188.4 acfma,f

4 Full Load Operating Pressure b 110 psigb

5 Maximum Full Flow Operating Pressure c 125 psigc

6 Drive Motor Nameplate Rating 40 hp

7 Drive Motor Nameplate Nominal Efficiency 91.7 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.98 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

37.3 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 22.9 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 14: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET

Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

2

Model Number: QGD-40-125 Air-cooled Water-cooled

# of Stages: 1

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f

182 acfma,f

4 Full Load Operating Pressure b 125 psig

b

5 Maximum Full Flow Operating Pressure c 140 psig

c

6 Drive Motor Nameplate Rating 40 hp

7 Drive Motor Nameplate Nominal Efficiency 91.7 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.53 kW

e

11 Total Package Input Power at Rated Capacity and Full

Load Operating Pressured

39.0 kWd

12 Specific Package Input Power at Rated Capacity and Full

Load Operating Pressureg

21.4 kW/100 cfmg

NOTES:

a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions.

b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet.

c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power.

d. Total package input power at other than reported operating points will vary with control strategy.

e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217).

f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate

at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % %

Below 0.5 Below 15 +/- 7 +/- 8

0.5 to 1.5 15 to 50 +/- 6 +/- 7

1.5 to 15 50 to 500 +/- 5 +/- 6

Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members.

CAGI has not independently verified the reported data.

Member

Page 15: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-40-150 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f 153.2 acfma,f

4 Full Load Operating Pressure b 150 psigb

5 Maximum Full Flow Operating Pressure c 160 psigc

6 Drive Motor Nameplate Rating 40 hp

7 Drive Motor Nameplate Nominal Efficiency 91.7 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.53 kWe

11 Total Package Input Power at Rated Capacity and Full Load Operating Pressured

37.1 kWd

12 Specific Package Input Power at Rated Capacity and Full Load Operating Pressureg 28.9 kW/100 cfmg

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % % Below 0.5 Below 15 +/- 7 +/- 8 0.5 to 1.5 15 to 50 +/- 6 +/- 7 1.5 to 15 50 to 500 +/- 5 +/- 6 Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Member

Page 16: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-50-100 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f

226 acfma,f

4 Full Load Operating Pressure b 100 psigb

5 Maximum Full Flow Operating Pressure c 115 psig

c

6 Drive Motor Nameplate Rating 50 hp

7 Drive Motor Nameplate Nominal Efficiency 92.4 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 11.2 kW

e

11 Total Package Input Power at Rated Capacity and Full

Load Operating Pressured

41.5 kWd

12 Specific Package Input Power at Rated Capacity and Full

Load Operating Pressureg 18.4 kW/100 cfm

g

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % %

Below 0.5 Below 15 +/- 7 +/- 8

0.5 to 1.5

Member

15 to 50 +/- 6 +/- 7

1.5 to 15

50 to 500 +/- 5 +/- 6

Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Page 17: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-50-110 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f

223 acfma,f

4 Full Load Operating Pressure b 110 psigb

5 Maximum Full Flow Operating Pressure c 125 psig

c

6 Drive Motor Nameplate Rating 50 hp

7 Drive Motor Nameplate Nominal Efficiency 92.4 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 11.2 kW

e

11 Total Package Input Power at Rated Capacity and Full

Load Operating Pressured

42.9 kWd

12 Specific Package Input Power at Rated Capacity and Full

Load Operating Pressureg 19.2 kW/100 cfm

g

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % %

Below 0.5 Below 15 +/- 7 +/- 8

0.5 to 1.5

Member

15 to 50 +/- 6 +/- 7

1.5 to 15

50 to 500 +/- 5 +/- 6

Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.

Page 18: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET

Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

2

Model Number: QGD-50-125 Air-cooled Water-cooled

# of Stages: 1

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f

221 acfma,f

4 Full Load Operating Pressure b 125 psig

b

5 Maximum Full Flow Operating Pressure c 140 psig

c

6 Drive Motor Nameplate Rating 50 hp

7 Drive Motor Nameplate Nominal Efficiency 92.4 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 14.08 kW

e

11 Total Package Input Power at Rated Capacity and Full

Load Operating Pressured

47.52 kWd

12 Specific Package Input Power at Rated Capacity and Full

Load Operating Pressureg

21.5 kW/100 cfmg

NOTES:

a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions.

b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet.

c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power.

d. Total package input power at other than reported operating points will vary with control strategy.

e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217).

f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate

at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % %

Below 0.5 Below 15 +/- 7 +/- 8

0.5 to 1.5 15 to 50 +/- 6 +/- 7

1.5 to 15 50 to 500 +/- 5 +/- 6

Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members.

CAGI has not independently verified the reported data.

Member

Page 19: COMPRESSOR DATA SHEET Rotary Screw Compressor

Form Number ROT 030 Rev 4 1-05

COMPRESSOR DATA SHEET Rotary Screw Compressor

MODEL DATA - FOR COMPRESSED AIR

1 Manufacturer: Quincy Compressor Date: 01/01/2009

Model Number: QGD-50-150 Air-cooled Water-cooled

# of Stages: 1 2

Oil-injected Oil-free VALUE UNIT

3 Rated Capacity at Full Load Operating Pressure a, f

184 acfma,f

4 Full Load Operating Pressure b 150 psigb

5 Maximum Full Flow Operating Pressure c 160 psig

c

6 Drive Motor Nameplate Rating 50 hp

7 Drive Motor Nameplate Nominal Efficiency 92.4 percent

8 Fan Motor Nameplate Rating (if applicable) 1.5 hp

9 Fan Motor Nameplate Nominal Efficiency 75.5 percent

10 Total Package Input Power at Zero Flowe 8.52 kW

e

11 Total Package Input Power at Rated Capacity and Full

Load Operating Pressured

43.98 kWd

12 Specific Package Input Power at Rated Capacity and Full

Load Operating Pressureg 23.89 kW/100 cfm

g

NOTES: a. Measured at the discharge terminal point of the compressor package in accordance with the CAGI/PNEUROP PN2CPTC2 Test

Code (Annex C to ISO 1217). ACFM is actual cubic feet per minute at inlet conditions. b. The operating pressure at which the Capacity (Item 3) and Electrical Consumption (Item 10) were measured for this data sheet. c. Maximum pressure attainable at full flow, usually the unload pressure setting for load/no load control or the maximum pressure

attainable before capacity control begins. May require additional power. d. Total package input power at other than reported operating points will vary with control strategy. e. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217). f, g. Tolerance is specified in the CAGI/PNEUROP PN2CPTC2 Test Code (Annex C to ISO 1217) as follows:

Volume Flow Rate at specified conditions Volume Flow Rate

f Specific Energy Consumption

g

m3 / min ft3 / min % %

Below 0.5 Below 15 +/- 7 +/- 8

0.5 to 1.5

Member

15 to 50 +/- 6 +/- 7

1.5 to 15

50 to 500 +/- 5 +/- 6

Above 15 Above 500 +/- 4 +/- 5

This form was developed by the Compressed Air and Gas Institute for the use of its members. CAGI has not independently verified the reported data.