20
computer SMART III Power factor relay

computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

Page 1: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

computer SMART IIIPower factor relay

Page 2: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

“If you do not think about your future, you cannot have one.”John Galsworthy, Nobel Prize in Literature

Page 3: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Beyond compensation

Page 4: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation
Page 5: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Compensation

Page 6: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Compensation

Measurement

Page 7: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Compensation

Measurement

Protection

Page 8: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Advanced compensation

Measurement of the 3 phases is equivalent to the reading of the company’s meter.

Regulatorcomputer SMART III

Company meter

Page 9: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Future vision

The possibility of changing from 1 to 3 transformers makes it possible to adapt to the requirements of any installation

without the need to replace the regulator.

Changing from 1 to 3 transformers in the following cases:

— Changes in reactive energy penalties. — Changes in consumption habits. — Significant unbalances in the system.

Measurement methodsI I I + N [V] → I I I [A]I I I + N [V] → I [A]I I [V] → I [A]

Page 10: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Measurement

Powerful three-phase power analyzer

Over 150 variables.

Regulator Analyzer

+ =

Page 11: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Safety and Protection

Residual current supervision Service continuity of the capacitor bank, only disconnecting those steps where leakages are detected.

Overtemperature protectionInternal temperature probe. Output relay dedicated to independently activate the fan.

Antiresonance protectionAntiresonance self-protection system that protects against the presence of harmonics.

Page 12: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Setup

Communication

PLUG & PLAY The setup is fully automatic by simply pushing a key.

RS-485 output with MODBUS protocol The communications system allows remote control, supervision and preventive maintenance of both the unit and the installation.

Page 13: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Flexibility

Up to 4 independent objective cosφ Capacity to adjust and activate 4 independent objective cosφ with digital inputs.

ON/OFF/AUTO Status, per step The ON function does not affect the measurement of regulated steps, saving time and money for the installation.

Operation meter and alarm Operation and maintenance alert meter.

Page 14: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Simplification of fixed compensation operations

The ON/OFF/AUTO configuration

— Can select a step for the fixed compensation of the power transformer.

— Saves the installation of a fixed independent group

Page 15: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

IndustryAvoids surcharges as a result of excessive or lack of compensation. Higher accuracy.

Page 16: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

SupermarketsWarns of compensation problems in the capacitor bank with alarms, preventing penalties in the electricity bill.

Page 17: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Office BuildingsFacilitates the maintenance of the capacitor bank.

Page 18: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Renewable energiesOffers remote control of the status of the capacitor bank and installation. Multipoint systems.

Page 19: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Energy efficiency technology

Page 20: computer SMART III - CIRCUTORJohn Galsworthy, Nobel Prize in Literature Beyond compensation Compensation Compensation Measurement Compensation Measurement Protection Advanced compensation

Tel. (+34) 93 745 29 00Fax: (+34) 93 745 29 14

[email protected]

Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain