605652_ATS110_EN_09-10.DOC 09/10 Operating Instruction REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control units for vibratory feeders REO-USA, Inc 8450 E 47th Street Indianapolis, IN 46226 USA Phone +1 (317) 899-1395 Fax +1 (317) 899-1396 http://www.reo-usa.com eMail: info@reo-usa.com

Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Embed Size (px)

Citation preview

Page 1: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

605652_ATS110_EN_09-10.DOC 09/10

Operating Instruction REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control

Con

trol u

nits

for v

ibra

tory

feed

ers

REO-USA, Inc

8450 E 47th StreetIndianapolis, IN 46226USA Phone +1 (317) 899-1395Fax +1 (317) 899-1396 http://www.reo-usa.com eMail: [email protected]

Page 2: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

1

User Technical Safety Information This description contains the necessary information for the correct application of the product described below. It is intended for use by technically qualified personal. Qualified personnel are persons who, because of their training, experience and position as well as their knowledge of appropriate standards, regulations, health and safety requirements and working conditions, are authorised to be responsible for the safety of the equipment, at all times, whilst carrying out their nor-mal duties and are therefore aware of, and can report, possible hazards (Definition of qualified employees according to IEC 364) Safety Instructions The following instructions are provided for the personal safety of operators and also for the protection of the described product and connected equipment.

Warning! Hazardous Voltage Failure to observe can kill, cause serious injury or damage

• Isolate from mains before installation or dismantling work, as well as for fuse changes or post installa-

tion modifications. • Observe the prescribed accident prevention and safety rules for the specific application. • Before putting into operation check if the rated voltage for the unit conforms with the local supply volt-

age. • Emergency stop devices must be provided for all applications. Operation of the emergency stop must

inhibit any further uncontrolled operation. • Electrical connections must be covered • The earth connection must be checked, for correct function, after installation. Specified Use The units described herein are electrical controllers for installation in industrial plant. They are designed for power adjustment on vibratory feed equipment. Contents User Technical Safety Information ............................................................................................................... 1 1.0 General................................................................................................................................................... 2 2.0 Technical Data........................................................................................................................................ 2 3.0 Declaration of Conformity....................................................................................................................... 2 4.0 Commissioning ....................................................................................................................................... 3

4.1 Assembling position............................................................................................................................ 3 4.2 Preliminary steps ................................................................................................................................ 3

4.2.1 Important points............................................................................................................................ 3 4.2.2 Operating frequency of the feeder coil ......................................................................................... 3

4.3 Settings ............................................................................................................................................... 3 5.0 Connections external.............................................................................................................................. 4 6.0 Connections internal............................................................................................................................... 5 7.0 Dimensions............................................................................................................................................. 6

!

Page 3: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

2

REO-USA INC.3250 North Post Road Suite 132

Indianapolis, IN 46226PH: 317-899-1395FX: 317-899-1396www.reo-usa.com

Input Output X4

10

0

20

30

4050

60

70

80

90

100

REOVIB ATS 110

1.0 General

Electronic control units for stepless adjustment of vibratory feeder throughput. The control units are suitable for feeders with a vibrating frequency of 60 Hz (50 Hz) and 120 Hz (100 Hz). The vibrator frequency is selected by using an internal link-switch on the printed circuit board. The feeder throughput can be adjusted by using the integrated potentiometer. An enable input is available for Stop/Start operation from contacts or a supervisory control system. Umin and Umax trimmers are provided to limit the throughput adjustment range. An integral soft-start reduces jolting when the unit is switched on or enabled. An internal regulation loop eliminates main voltage variations. The enclosed version includes mains input and feeder output cables. In the front panel there is a mains switch and a throughput adjustment potentiometer. The potentiometer can be used to set the feed rate from 10...100%, it´s also possible to reduce the range of output voltage by using the internal Umin and Umax trimmers. The Track-control operate with a PNP track-sensor that calls for product when the level is low and this causes the feeder to switch on and off after preset time-delays (t-on, t-off) have elapsed.

2.0 Technical Data

REOVIB ATS 110 Stock Code 6056 52 Supply voltage 110 V / 120 V, +/- 10 %, (factory setting)

220 V / 240 V, +/- 10 % Mains frequency 50/60 Hz Output voltage 20... 105 V, (factory setting)

40…210 V Output current 0,2…15 A max. Vibrating frequency

3000 (3600), 6000 (7200) (factory setting)

Set point source Internal Potentiometer 0... 10 VDC, 22 kR

0(4)... 20 mA, 250 R Enable 24 V, DC, 5 mA

Contacts Sensor supply 24 V, DC / 50 mA Construction IP 54 Operating temperature 0... 45 °C Storage temperature -20... +70 °C

3.0 Declaration of Conformity

We declare that these products conform with the following standards and directives.: EN 61000-6-2 and EN 61000-6-4 in accordance with Directive 2004/108/EG.

REO ELEKTRONIK AG, D-42657 Solingen

Page 4: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

3

4.0 Commissioning

4.1 Assembling position

Please fasten the devices on a vibration-free underground and take care for sufficient air circulation.

4.2 Preliminary steps

• Check that the unit is correct for the local mains supply (rating plate information) and that it is cor-rectly rated for the feed system.

• Connect the controller according to the connection diagram

4.2.1 Important points

When applications with frequently on and off cycles are required, use the intended enable input. It is prohibited to open the current circuit with a switch or a contactor while the feeder is running, because that may cause damage to the controller.

4.2.2 Operating frequency of the feeder coil

It is possible that the current flowing through the coil will increase for a small frequency adjustment, and so this should be checked with a true RMS instrument for each new application as well as monitoring the coil for heat build-up. The coil should be designed for the correct operating frequency to prevent excessive current draw and the consequential overloading of the coil. 4.3 Settings

Check the input voltage before switching on the controller. The controller is factory set to 110 V / 120 V input Voltage, in case of main supply of 220 V / 240 V, please remove the cover and turn the switches into 220 V / 240 V position. Check the Frequency of the Feeder and use the switch witch also can be found inside the controller for the right setting. Umin and Umax trimmers are provided to limit the throughput adjustment range, they are also located inside the controller.

!

!

Page 5: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

4

5.0 Connections external

INPUT OUTPUT

1 2

34

OUTPUTINPUT

X4

1 = Output 24V DC2 = 3 = GND4 = Input

Sensor track control (X4)

1 2

34

Page 6: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

5

6.0 Connections internal

adjustments internal wiring

PE

PE

PE

2625

2221

2423

45

67

89

Input cable

Output cable

Main switch

InternalPotentiometer

10 Kohm

link

G T1

T2

X13

X11

X4

X5

X12

X10

X9

Housing

24V

0...+

10 V

0(4)

...20

mA

+

-

Inhibit

+

-

switch

exte

rnal

1a 2a

1 2

4 5 6 7 8 9

29 28 27 1 2 3

PE PE PE 26 25 22 21 24 23

Soft start

t

Page 7: Control units for vibratory feeders - REO-USA, Inc. ATS 110 Manual.pdf · REOVIB ATS 110 Control unit for Vibratory Feeders With main voltage compensation and Track control Control

Operating Instructions REOVIB ATS 110

6

7.0 Dimensions

131

23

REO-USA INC.3250 North Post Road Suite 132

Indianapolis, IN 46226PH: 317-899-1395FX: 317-899-1396www.reo-usa.com

Input Output X4

10

0

20

30

4050

60

70

80

90

100

REOVIB ATS 110

Ø5,0

Ø5,0

205

193

6,5

153