7
MAKE IT BECKER. SV 300/1 DATA SHEET SIDE CHANNEL BLOWERS single stage air-cooled

DATA SHEET SV 300/1 SIDE CHANNEL BLOWERS

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

MAKE IT BECKER.

SV 300/1DATA SHEET

SIDE CHANNELBLOWERSsingle stage

air-cooled

2 • BECKER SV 300/1

123*▪▪

Vacuum connection (G2½)

Pressure connection (G2½)

Optional vibration dampers (rubber buffer) for vertical installation

Device dimensions without pedestal under the silencer, with rubber buffers on the enclosure cover

The motor illustration may vary

Dimensions in mm [inch]

1) According to DIN EN ISO 11203, accuracy class of measurement: class 2, extended measurement uncertainty: 3 dB1 m [39.4 inch] distance, at medium load, both connection sides piped

Blast air rate Pressurerelative

Motors Emission sound pressure level 1)

Weightwith motor

L

m³/h mbar kW dB(A) kg mm [inch]

50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz 60 Hz

290 [11.4]

190 [7.5]

315 [12.4]

241

[9.5

] 151

[5.9

]370 [14.6]

10[0

.4]

152 [6]

L

72.2[2.8]

290 [11.4]

365 [14.4]

374.7 [14.8]

Ø10.2[0.4]

G 2

½

410*

[16.

2*]

426

[16.

8]

M6

16*[0.63]

Ø33090°

3

1 2

[Ø13]

325 390 +165 +140 2.2 2.6571.0

(+115 mbar)69.4

(+95 mbar)42.0 469 [18.5]

325 390 +250 +230 3.0 3.671.0

(+165 mbar)

71.8

(+155 mbar)44.5 494 [19.5]

325 390 +340 +320 4.0 4.872.0

(+255 mbar)

73.5

(+235 mbar)50.0 538 [21.2]

BECKER SV 300/1 • 3

3~ Motors

# 50 Hz 60 Hz Version

kW V min-1 A kW V min-1 A

▪ Current consumption and rotation speed may vary. Tolerance in each case -1.5/+2%

01 2.2 Δ230/Y400 IE3 2910 7.7/4.45 2.65Δ265/Y460 IE3 3510 7.6/4.4 UL • CSA

IP55 • ISO F • bimetalΔ230/Y400 3460 8.3/4.6

02 2.65YY230/Y460 IE3 3510 8.6/4.3 UL • CSA • CC

IP55 • ISO F • bimetalYY208/Y – 3460 9.2/ –

03 3.0 Δ230/Y400 IE3 2890 10.6/6.1 3.6Δ265/Y460 IE3 3500 10.6/6.1 UL • CSA

IP55 • ISO F • bimetalΔ230/Y400 3460 11.6/6.7

04 3.6YY230/Y460 IE3 3510 12.4/6.2 UL • CSA • CC

IP55 • ISO F • bimetalYY208/Y – 3480 13.0/ –

05 3.0 Δ200/Y350 IE3 2920 13.9/8.0 3.6Δ220/Y380–400 IE3 3500 12.6/7.3

IP55 • ISO F • bimetalΔ200/Y350 3470 13.2/7.6

06 4.0 Δ230/Y400 IE3 2930 14.6/8.4 4.8Δ265/Y460 IE3 3520 14.3/8.25 UL • CSA

IP55 • ISO F • bimetalΔ230/Y400 3490 15.4/8.85

07 4.8YY230/Y460 IE3 3520 16.5/8.25 UL • CSA

IP55 • ISO F • bimetalYY208/Y – 3500 17.1/ –

08 4.0 Δ200/Y350 IE3 2930 16.6/9.6 4.8Δ220/Y380–400 IE3 3520 16.6/9.6–9.45

IP55 • ISO F • bimetalΔ200/Y350 3490 17.7/10.1

4 • BECKER SV 300/1

0 +10 +20 +30 +40100 110 120 130 140

400

2.65 kW

2.2 kW

3.0 kW

3.6 kW

50 Hz

60 Hz

4.0 kW

4.8 kW

350

300

250

200

150

100

50

6000

5000

4000

3000

2000

1000

0 0

150

50 Hz

60 Hz

300

100

50

200

100

500 32

5

50 Hz

60 Hz4

3

2

1

6

4

2

0 0

0 +100 +200 +300 +4001000 1100 1200 1300 1400

Reference data (atmosphere): 1000 mbar (100 kPa), 20°C (68°F)Tolerance: ±10%Temperature: Inlet air 0°C ... 40°C (32°F ... 104°F), Ambient air -10°C ... 40°C (14°F ... 104°F)

PRESSURE [kPa]relative

absolute

BL

AS

T A

IR R

AT

E [

m³/

h]

BL

AS

T A

IR R

AT

E [

l/m

in]

EX

HA

US

T A

IR T

EM

PE

RA

TU

RE

[°C

]

EX

HA

US

T A

IR T

EM

PE

RA

TU

RE

[°F

]

MO

TO

R S

HA

FT P

OW

ER

[k

W]

MO

TO

R S

HA

FT P

OW

ER

[h

p]

relativeabsolute

PRESSURE [mbar]

BECKER SV 300/1 • 5

VARIANTS AND ACCESSORIES

▪ Dimensions in mm [inch] – For other dimensions, see the figure on page 2.

SUCTION FILTER

▪ Paper or polyester insert

PRESSURE SAFETY VALVE

SUCTION FILTER ANDPRESSURE SAFETY VALVE

439 [17.3]

365 [14.4]

364 [14.3]

426 [16.8]

G2½ G2½

365 [14,4]

450 [17,7]

271 [10,7]

162[6,4]

241

[9,5

]3

9,5

[1,6

]

185[7,3]184[7,2]

450 [17,7]

G2½

G2½

254 [10]265 [10.4]519 [20.4]

6 • BECKER SV 300/1

216 [8.5]

Ø16

0 [Ø

6.3]

24[0

.9]

35[1.4] Ø28

h6(

) E

-0.0

13M6M6M6

[Ø1.

1]

621 [24.5]

60[2.4]

281.5 [11.1]

M10M10

Ø165

Ø130 H7

Ø20

0[Ø

7.9]

Ø28

[Ø1.

1]

[Ø5.1]

[Ø6.5]

M10

OTHER VARIANTS AND ACCESSORIES

▪▪▪▪▪

With increased corrosion protectionVARIAIR SV 300/1 with frequency inverter VAU4/4 for 87 Hz operation 1)

VARIAIR SV 300/1 with frequency inverter VAU7.5/3 for 100 Hz operation 1)

VARIAIR SV 300/1 gas-tight (inert gases) with frequency inverter VAU7.5/3 for 100 Hz operation 1)

Sound proof box SH 18 1)

II 3G/3G c IIB T3II 3D c IIIB T 125

325 +250

3.3 Δ230/Y400 2830 10.6/6.12 71

ATEX SV 300/1 WITH MOTOR

▪▪

With coupling for flange motorThe motor must be supported!

WITHOUT MOTOR

▪▪▪

With free shaft endMax. 5600 rpm with V-belt pulleyPossible performance data see VARIAIR SV 300/1 1)

Sound proof box SH 18

WITHOUT MOTOR

▪▪

With coupling for flange motorThe motor must be supported!

ATEX zone Blast air rate Pressure relative

m³/h (50 Hz) mbar (50 Hz)

1)

▪▪

See separate data sheetCurrent consumption and rotation speed may vary. Tolerance in each case -1.5/+2%. The motor illustration may vary.Dimensions in mm [inch] – For other dimensions, see the figure on page 2.

50 Hz Total weight

kW V min-1 A kg

MAKE IT BECKER.

www.becker-international.com

20

21-

02

-03

Rig

ht

of

mo

difi

cat

ion

re

serv

ed