OLYMPUSCollaboration Meeting

Luminosity MonitorCalorimeter

David Rodríguez PiñeiroDavid Rodríguez PiñeiroMainz UniversityMainz University

OLYMPUS Collaboration MeetingOLYMPUS Collaboration MeetingDESYDESY

23. 02. 201023. 02. 2010

Page 2: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 22

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

1.– Composition- Crystals- Frames- Assembly- Collimator- Box

2.– OLYMPUS Integration- Magnetic Field- Beam Pipe Modification- Interference

3.- Support & Alignment 4.- Summary

Page 3: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 33

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

   Length Total Each Block

Type1 150,0 9 4-5

Type2 155,1 8 4

Type3 160,6 4 2

Type4 166,3 5 2-3

Type5 172,3 6 3

Type6 178,7 5 2-3

Type7 185,4 6 3

Crystals; PbF2

Page 4: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 44

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Frames

Cutting of the A4 Frames

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 5: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 55

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Assembly

PMTBase

Crystal

Frame

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 6: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 66

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Collimator I

Optimized Shape from the Target to Protect PMT and Bases

10 cm Long

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Lead

Page 7: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 77

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Collimator II

200 mm 200 mm R4,47 mm

Cut Views

Pre

limin

ary

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 8: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 88

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Box I

Fixation Collimator: With Screw

Crystals Support: Softer Material

1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 9: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 99

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Box III

Lid for the Box: Light Tight

Box II 1.– Composition

- Crystals

- Frames

- Assembly

- Collimator

- Box

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Cover of the Collimator Hole

Page 10: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1010

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

2.– OLYMPUS Integration

Page 11: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1111

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Magnetic Field ICoils and Quad

Magnetic Fringe Field from Quad Unknown

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Page 12: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1212

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Box III

Lid for the Box: MuMetal

Box: Soft iron

Detailed Studies to Be Done

Magnetic Field II 1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Page 13: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1313

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Beam Pipe Modification

Clear Path from the Target

Windows

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Page 14: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1414

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Angle; Interference I

Energy 2,0 GeV -> Angle 1,28º

1,28º

3200 mm

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Page 15: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1515

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Angle; Interference II

Energy 2,3 GeV -> Angle 1,19º

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Calorimeter-Beam Pipe Clash

Page 16: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1616

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Angle; Interference IIIBeam Pipe Radius:

19,05 mm

Minimum Distance: 2,08 mm

(at 2,0 GeV)

Beam Pipe Tolerance?

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Kapton foil in between: Electrical Insulation

Page 17: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1717

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Angle; Interference IV4 GeV: Beam Pipe Radius: 19,05 mm

2 GeV: Beam Pipe Radius Decrease? More Space

1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Page 18: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1818

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Angle; Interference V 1.– Composition

2.– OLYMPUS

Integration

- Magnetic Field

- Beam Pipe

Modification

- Interference

3.- Support &

Alignment

4.- Summary

Beam Position Precision?

Beam Angle Precision?

Movement Needed Due to Beam Alignment?

Page 19: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 1919

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

3.- Support & Alignment

Page 20: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2020

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 21: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2121

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 22: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2222

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 23: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2323

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 24: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2424

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 25: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2525

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 26: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2626

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 27: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2727

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment 1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Enough Space for Alignment?

Page 28: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2828

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment

Safety Factor > 8

Aluminium

Regarding the elastic limit

1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Full LoadAttached to the Frame

Page 29: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 2929

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Support and Alignment

Aluminium

Total Deformation

< 0,25 mm

1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Page 30: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 3030

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Main Design Done

Free Path from the Target

Inputs needed:

- Quad Magnetic Fringe Field

- Beam Pipe Tolerance

- Beam Position and Angle Precision?

Enough Space for Support and Alignment?

1.– Composition

2.– OLYMPUS

Integration

3.- Support &

Alignment

4.- Summary

Summary

Page 31: David Rodríguez Piñeiro Mainz University OLYMPUS Collaboration Meeting DESY 23. 02. 2010

23/02/201023/02/2010 David Rodríguez Piñeiro - Mainz University - OLYMPUS MeetingDavid Rodríguez Piñeiro - Mainz University - OLYMPUS Meeting 3131

Luminosity Monitor, CalorimeterLuminosity Monitor, Calorimeter

Personal Contact:

[email protected]: +49 (0) 6159171/1634

web.mit.edu/OLYMPUS

Thank you!