2
Deck Jet Model WFJ500 PAK 4 ISWFJ100 REV B Plumbing Layout A = B = C = D A ≠ B ≠ C ≠ D Ball Valve Valve for flow control Pool ! ! ! ! 1 2 3 4 Number of Deck Jets in System Main Feed Pipe Size (inches) Flow Loop Pipe (inches) Individual Deck Jet Feeds (inches) 1 - 5 1 - 1/2 1 3/4 6 - 10 2 1 - 1/2 3/4 Recommended Plumbing Size* *See plumbing layout for example flow loop Wall Returns, Bypass, other features, etc. This product should be installed and serviced by a qualified pool professional. Improper installaon or operaon will void the warranty. For best results with mulple deck jets, plumb using an equal flow loop or variaon thereof. Maintain symmetry and consistency between deck jet feedlines in mulple jet systems. Build feed lines of equal length using the same number of joints and fings. The Hayward Deck Jet 500 is designed for a maximum flow rate of 5gpm at 10.7ſt of head. Nozzle adjustment will not shut off flow to Deck Jet. See table for range of adjustment. 1 2 3 4 60 80 3 4 5 3 4 5 2.3 3.1 3.9 2.9 3.9 4.8 4.0 6.4 9.6 1.8 2.4 3.0 2.6 4.0 5.6 1.3 2.3 2.9 3.7 5.2 6.9 4.2 5.8 8.2 3.0 3.9 4.9 3.9 5.3 7.3 4.3 6.3 8.4 4.3 6.3 8.4 4.5 6.8 8.9 4.3 6.4 8.5 Flow Rate (GPM) X (ſt) Y (ſt) Head Loss (ſt of head) Max Open Min Open Max Open Min Open Max Open Min Open Max Open Min Open α (deg)

Deck Jet Model WFJ500 PAK 4 - Hayward Docshaywarddocs.info/wp-content/uploads/2017/10/Deck-Jet_WFJ500PAK4… · Deck Jet Model WFJ500 PAK 4 ISWFJ100 REV B ... consistency between

Embed Size (px)

Citation preview

Page 1: Deck Jet Model WFJ500 PAK 4 - Hayward Docshaywarddocs.info/wp-content/uploads/2017/10/Deck-Jet_WFJ500PAK4… · Deck Jet Model WFJ500 PAK 4 ISWFJ100 REV B ... consistency between

Deck Jet Model WFJ500 PAK 4

ISWFJ100 REV B

Plumbing Layout

A = B = C = D A ≠ B ≠ C ≠ D

Ball Valve

Valve for flow control

Pool

!

!

!

!

1

2

3

4

Number of Deck Jets in System

Main Feed Pipe Size (inches)

Flow Loop Pipe (inches)

Individual Deck Jet Feeds (inches)

1 - 5

1 - 1/2

1

3/4

6 - 10

2

1 - 1/2

3/4

Recommended Plumbing Size*

*See plumbing layout for example flow loop

Wall Returns, Bypass, other features, etc.

This product should be installed and serviced by a qualified pool professional. Improper installation or operation will void the warranty.

For best results with multiple deck jets, plumb using an equal flow loop or variation thereof. Maintain symmetry and consistency between deck jet feedlines in multiple jet systems. Build feed lines of equal length using the same number of joints and fittings.

The Hayward Deck Jet 500 is designed for a maximum flow rate of 5gpm at 10.7ft of head.

Nozzle adjustment will not shut off flow to Deck Jet. See table for range of adjustment.

1

2

3

4

60

80

3

4

5

3

4

5

2.3

3.1

3.9

2.9

3.9

4.8

4.0

6.4

9.6

1.8

2.4

3.0

2.6

4.0

5.6

1.3

2.3

2.9

3.7

5.2

6.9

4.2

5.8

8.2

3.0

3.9

4.9

3.9

5.3

7.3

4.3

6.3

8.4

4.3

6.3

8.4

4.5

6.8

8.9

4.3

6.4

8.5

Flow Rate(GPM)

X(ft)

Y(ft)

Head Loss(ft of head)

Max Open

Min Open

Max Open

Min Open

Max Open

Min Open

Max Open

Min Open

α(deg)

Page 2: Deck Jet Model WFJ500 PAK 4 - Hayward Docshaywarddocs.info/wp-content/uploads/2017/10/Deck-Jet_WFJ500PAK4… · Deck Jet Model WFJ500 PAK 4 ISWFJ100 REV B ... consistency between

Remove nozzle and insert sealing ball.

Remove sealing ball and insert nozzle.

Keep cap flush with deck.

WFXJ 500 CPAK4Cover - 4 Pack

WFXJ 500 KITNozzle and retainer kit(Includes winterizing ball)

Twist nozzleto adjust flow.

Pull tabs(inwards)to remove.(6 Places)

Do not blockbottom ofhousing withconcrete.

Finish deck to top ofrubber cap.

TEST

Cut pipe 2 5/8” from deck surface.

3/4” supply pipe<50 PSI MAX<3.5 BAR MAX

Housingdesignedto drainunder deck.

WINTERIZING

Replacement Parts

OPERATION

Align arrows. Rotate 3x’s to adjust cap flush with deck.

PVC Cement on Feed Pipe ONLY

1

4 5 6

7 8 9

10 11 12

2 3