20
Specialized rotary and control switches DISCREPANCY SWITCHES CONTROL DISCREPANCY SWITCHES STANDARD ELECTRIC DIAGRAMS

Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

Embed Size (px)

DESCRIPTION

Power Distribution Devices

Citation preview

Page 1: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

Specialized rotary and control switches

DISCREPANCY SWITCHESCONTROL DISCREPANCY SWITCHES

STANDARD ELECTRIC DIAGRAMS

Page 2: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

www.comeletric.it

Models Available Index Available for:

FRM10 M101 - M107

Maintained Action Contact :M102

DR20

FRMM 6

The maximum number of packets varies depending on the series and model.The maximum number of the packets is stated in the catalogue and in the dimensional drawing of the various models.

DR105 - DR108

Maintained Action Contact :DR104

M601 - M604 - M612 -M614

M701- M704 - M705

M201 - M202

FRMM 6 IP20

FRMM 2000

Series:

Series:

Series:

Series:

Series:

Models:

Models:

Models:

Models:

Models:

Page 3: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

1www.comeletric.it

Ordering Method

Product Coding

1

2

3 n° of Packets.

1

1 2

3 4

one Packet

4 n° of Electric diagram.

- _ + -circuit arrangement code

1 32 4

M

5

5 n° Escutcheon Plate.

In this catalogue you may find some electric diagrams and instructions for composing independently order codes of standarddiscrepancy switches.For special diagrams or diagrams which are not present in this catalogue use the form on page ....Schemes of this catalogue and their use in the codes are applicable only to the series of switches shown on the previous page.They are not applicable to the series FR10 - R20 - R16 - FRMC 6 - FRMC 6 IP20 - FRMC 2000 - FR10 62 - FR10 68 - FR10 adf -FRB10 - FRMC 6 80 - LR20.These diagrams and the composition of these codes are available in their respective catalogues.

Model Number of the switch.

Model number means the assembly and construction form unique for each Discrepancy switch, this reference identifies the

series,the type of the discrepancy switch, the dimensions , the type of knob , etc......

This model number is indicated in the catalogues along with its dimensional drawing and panel cutout.In the previous page there is a

list, for the various series of model numbers of the most common types.

Type of Movements.

This is the reference of the type of movement and the positions that the switch should have, from a minimum of 2 up to a maximum

of 4 ,for the series of discrepancy switches shown in this catalogue.

The movements of the knob can be of 45° or 90 °.

As number of packets, it means by how many isolating discs should be made the switch. The number of packets affects

the number of poles required.Generally in each packet you have a contact NORMALLY OPEN and a contact NORMALLY

CLOSED, but this can vary depending on the wiring diagram.In each reference catalogue, next to the table of lengths, it is

shown the maximum number of packets suitable for that specific model number.

This number, along with point 2 and 3 is an indication of the electric diagram of the switch required.It includes the wiring diagram

in reference to the diagrams shown below.It has no specific meaning, it is just a sequence number that is used to represent a specific

scheme of the switch assembly.

This code is referred to the shape , type and engraving of the Frontplate. On page 15 of this catalogue , all instructions to create

codes of the frontplates frequently used.

Page 4: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

2 www.comeletric.it

Standard Development Diagrams

Circuit Arrangement n° A01_01

The Circuit arrangement number has to be mentioned in the product code (point 2-3-4).

Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

1

X

2

3 4

XOC

O

CX1

X2

1

1

X

2

3 4

2

5 6

7 8

XOC

O

C

XX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

XOC

O

C

XXXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

XOC

O

C

XXXXXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

5

17 18

19 20

XOC

O

C

XXXXXXXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

5

17 18

19 20

6

21 22

23 24

XOC

O

C

XXXXXXXXXX

X1

X2

A02_01

A03_01 A04_01

A05_01 A06_01

Type : A

Circuit Arrangement n° A01_03 Circuit Arrangement n°

1

1

X

2

3 4

XOC

C

X1

X2

1

1

X

2

3 4

2

5 6

7 8

XOC X

X

X1

X2

A02_03

O

C

O

HORIZONTAL MOUNTINGHORIZONTAL MOUNTING

Page 5: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

3www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

XOC X

XXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

XOC X

XXXXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

5

17 18

19 20

XOC X

XXXXXXX

X1

X2

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

5

17 18

19 20

6

21 22

23 24

XOC X

XXXXXXXXX

X1

X2

A03_03 A04_03

A05_03 A06_03

Circuit Arrangement n° B03_01 Circuit Arrangement n° B04_01

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

XOC

O

C

XXXX

X1

X2

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

XOC

O

C

XXXXXX

X1

X2

C

O

C

O

C

O

C

O

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

Circuit Arrangement n° Circuit Arrangement n°B01_01 B02_01

1

1

X

1

2 4

XOC

O

CX1

X2

1

1

X

1

3 4

2

5 5

7 8

XOC

O

C

XX

X1

X2

Type : B

Page 6: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

4 www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°B01_03 B02_03

1

1

X

1

2 4

XOC

X1

X2

1

1

X

1

3 4

2

5 5

7 8

XOC X

X

X1

X2

Circuit Arrangement n° Circuit Arrangement n°B05_01 B06_01

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

5

17 17

19 20

XOC

O

C

XXXXXXXX

X1

X2

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

5

17 17

19 20

6

21 21

23 24

XOC

O

C

XXXXXXXXXX

X1

X2

C

O

C

O

Circuit Arrangement n° B03_03 Circuit Arrangement n° B04_03

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

XOC X

XXX

X1

X2

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

XOC X

XXXXX

X1

X2

C

O

C

O

Circuit Arrangement n° Circuit Arrangement n°B05_03 B06_03

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

5

17 17

19 20

XOC X

XXXXXXX

X1

X2

1

1

X

1

3 4

2

5 5

7 8

3

9 9

11 12

4

13 13

15 16

5

17 17

19 20

6

21 21

23 24

XOC X

XXXXXXXXX

X1

X2

C

O

C

O

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

Page 7: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

5www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°C03_01 C04_01

Circuit Arrangement n° C02_04 Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°SC02_01

Circuit Arrangement n° Circuit Arrangement n°C01_01 C02_01

1

1

X

2

3 4

XOP.

CL.

0X1

X2

0

OP. CL.

1

1

X

2

3 4

2

5 6

7 8

XOP.

CL.

0

XX

X1

X2

0

OP. CL.45°45° 45°45°

Type : C

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

XOP.

CL.

0

XXXX

X1

X2

0

OP. CL.45°45°

1

1

X

2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

XOP.

CL.

0

XXXXXX

X1

X2

0

OP. CL.45°45°

1

1

X

2

3 4

2

5

7

XOP.

CL.

0

X

X1

X2

0

OP. CL.45°45°

X

1

1

X

2

3 4

2

5 6

7 8

3

9

11

XOP.

CL.

0

XX

X1

X2

0

OP. CL.45°45°

XX

SC03_01(2-1)

1

1

X

2

3 4

2

5 6

7 8

XOP.

CL.

0

XX

X1

X2

0

OP. CL.45°45°

X X

1

1 2

3 4

2

5 6

7 8

3

9 10

11 12

4

13 14

15 16

OP.

CL.

0X1

X2

0

OP. CL.45°45°

XXXX

X XXXXX

X X

C04_04(2-2)

Page 8: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

6 www.comeletric.it

Principle of operation Type : D - E and T.The switches with the movements type D - E and T are basically called control discrepancy switches.The control

discrepancy switch has two fixed positions with a movement of 90°and two extra impulses of 45° on the

positions of open and close.The knob is first rotated by 90° to command the relative Disconnector

Switch/Circuit Breaker. This is however, a “ pre-selection” phase of the desired command , the operation is

confirmed by pressing and rotating the knob by 45°, which, once released, will return automatically into

position.The Type T is the discrepancy switch with the MAINTAINED ACTION CONTACTS, these contacts

maintain the last confirmed operation until the opposite operation is confirmed.The Type F is the same of type

D and E but with "0" position.

Additional Information

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

D01_01 D01_05

D01_08 D01_09

D02_01 D02_08

Standard Development Diagrams The Circuit arrangement number has to be mentioned in the product code ( point 2-3-4).

1

2

X

4

3 3

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

1

1 2

4 3

OP.

CL.

X1

X2

0C

O

C OP.

OP.

45°

45°

X

X

1

2

X

4

3 3

X

OP.

CL.

X1

X2

0C

C

O

OP.

CL.

45°

45°

X

X

1

1 2

4 3

OP.

CL.

X1

X2

0C

X

X

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

X

X

O

C

CL.

OP.

45°

45°

C

O

OP.

CL.

45°

45°

HORIZONTAL MOUNTING HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

Page 9: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

7www.comeletric.it

Circuit Arrangement n° D02_06 Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

D02_09

1

2

X

4

3 3

2

6 8

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

XXXX

X

1

2

X

4

3 3

2

5

7

X

OP.

CL.X

X1

X2

0C

X

XXX

1

1 2

4 3

2

6 8

7 7

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

XXXX

X

1

1 2

4 3

2

6 8

7 7

OP.

CL.

X1

X2

0C

X

XXXX

X

C

O

OP.

CL.

45°

45°

1

1

X

2

3 4

2

5 6

8 7

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

1

2

X

4

3 3

2

6

8

X

OP.

CL. X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

XX

1

2

X

4

3 3

2

6

8

X

OP.

CL. X

X1

X2

0C

X

X

XX

C

O

OP.

CL.

45°

45°

1

2

X

4

3 3

2

5

7

X

OP.

CL.X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

XXX

C

O

OP.

CL.

45°

45°

D02_43(1-1) D02_02

D02_45(1-1) D02_47(1-1)

D02_48(1-1)D02_45(1-1)

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

Page 10: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

8 www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

X

X

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

10

12

XXX

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9

11

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

X

X

3

9 10

12 11

X

X

C

O

OP.

CL.

45°

45°

Circuit Arrangement n°

1

2

X

4

3 3

2

6 8

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

X

XXXX

X

1

2

X

4

3 3

2

6 8

7 7

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

XXXX

X

C

O

OP.

CL.

45°

45°

1

1

X

2

4 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

10 12

11 11

X

X

1

1

X

2

4 3

2

6 8

7 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

10 12

11 11

XXX

X

D03_01 D03_08

D03_02 D03_15

D03_05 D03_06(2-1)

D03_50(1-1-1) E03_01

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

10

12

XX

Page 11: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

9www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

X

X

Circuit Arrangement n°

D04_01 D04_08

D04_02 D04_15

D04_05 D04_06(2-2)

E04_01 D04_51(1-2-1)

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

4

13 14

16 15

X

X

1

2

X

4

3 3

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

C

O

OP.

CL.

45°

45°

1

2

X

4

3 3

2

6 8

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

C

O

OP.

CL.

45°

45°

XXX

X

6 8

7 7

XXX

X

1

1 2

4 3

2

5 6

8 7

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°45°

3

9 10

12 11

4

14 16

15 15

1

1 2

4 3

2

5 6

8 7

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

3

10 12

11 11

4

14 16

15 15

X

X

X

X

X

XXXX

X

X

X

X

XXXX

XXXX

X

1

2 4

3 3

2

5 6

8 7

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

3

9 10

11 12

4

13 14

15 16

1

2 4

3 3

2

5 6

8 7

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

3

9 10

12 11

4

10

12

XXX

X

X

X

X

X

XXXX

XX

X

X

X

XX

X

X

Page 12: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

10 www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

2

X

4

3 3

2

6 6

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

Circuit Arrangement n°

D04_50(2-1-1) E04_12(2-1)

D04_43(1-3) D04_43(2-2)

D05_01 D05_08

D05_02 D05_15

4

14

16

XXX

X

X

X

XXX

1

1

X

2

3 4

2

5 6

7 8

X

OP.

CL.

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

XXX

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

5

13 14

16 15

X

X

X

X

C

O

OP.

CL.

45°

45°

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

5

13 14

16 15

X

X

C

O

OP.

CL.

45°

45°

XXX

XXXX

X

1

1

X

2

3 4

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

X

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

2

6 6

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

4

XXX

XXX

9 10

12 11

X

X

Page 13: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

11www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

1

2

X

4

3 3

2

6 6

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

Circuit Arrangement n°

D04_50(2-1-1) E04_12(2-1)

D04_43(1-3) D04_43(2-2)

D05_01 D05_08

D05_02 D05_15

4

14

16

XXX

X

X

X

XXX

1

1

X

2

3 4

2

5 6

7 8

X

OP.

CL.

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

XXX

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

5

13 14

16 15

X

X

X

X

C

O

OP.

CL.

45°

45°

HORIZONTAL MOUNTING

HORIZONTAL MOUNTING

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

5

13 14

16 15

X

X

C

O

OP.

CL.

45°

45°

XXX

XXXX

X

1

1

X

2

3 4

2

5 6

8 7

X

OP.

CL. X

X

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

X

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

2

6 6

7 7

X

OP.

CL.

X1

X2

0C

O

CCL.

OP.

45°

45°

X

X

3

9 10

12 11

4

XXX

XXX

9 10

12 11

X

X

Page 14: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

12 www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n°

D06_02 D06_08

E06_01 E06_52(1-2)

D06_50(2-3-1) E06_14(1-3)

D06_43(1-5) D06_43(2-4)

1

1

X

2

3 4

2

X

OP.

CL.

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

X

5 6

8 7

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

6

13 14

16 15

X

X

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

5

17 18

20 19

X

X

6

21 22

24 23

X

X

C

O

OP.

CL.

45°

45°1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

X

X

4

13 14

16 15

X

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

17 18

20 19

X

X

6

21 22

24 23

X

XXXX

XXXX

X

HORIZONTAL MOUNTING

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

11 12

XX

4

14 16

15 15

5 6

8 7

O

CCL.

OP.

45°

45°

5

17 18

20 19

6

21 22

23 24

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

11 12

XX

4

14

16

X

5 6

8 7

O

CCL.

OP.

45°

45°

5

17 18

20 19

6

21 22

24 23

X

XXXX

XXX

X

X

X

XXX

XX

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

12 11

4

13 14

16 15

X

6 8

7 7

O

CCL.

OP.

45°

45°

5

17 18

20 19

6

22

24

XX

X

XXXX

X

X

X

X

X

1

2

X

4

3 3

2

X

OP.

CL.

X1

X2

0C

X

X

3

9 10

11 12

XX

4

13 14

16 15

5 6

8 7

O

CCL.

OP.

45°

45°

5

17 18

19 20

6

21 22

23 24

X

XXX

X

X

X

X

1

1

X

2

3 4

2

X

OP.

CL.

X1

X2

0C

3

9 10

12 11

X

X

4

13 14

16 15

X

X

5 6

7 8

O

CCL.

OP.

45°

45°

5

13 14

16 15

X

X

6

13 14

16 15

X

XXX

Page 15: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

13www.comeletric.it

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n° Circuit Arrangement n°

Circuit Arrangement n°

D08_01 D08_02

E08_01 F04_01

F03_02 T02+1_01

T02+2_01 T03+1_02

1

2

X

4

3 3

X

OP.

X1

X2

N.A. OP.

X

XO

X

+2

13 14

15 16

2

5 6

8 7

X

O

CCL.

OP.

45°

45°

XX

CN.A.CL.

CL. X

X

+1

9 10

11 12

X

X

1

2

X

4

3 3

X

OP.

X1

X2

N.A. OP.

X

XO

X

+1

13 14

15 16

2

5 6

8 7

X

O

CCL.

OP.

45°

45°

XX

CN.A.CL.

CL. X

X

3

9 10

11 12

XX

AVAILABLE ONLY IN DR20 AND FRM10 SERIESAVAILABLE ONLY IN DR20 AND FRM10 SERIES

AVAILABLE ONLY IN DR20 AND FRM10 SERIES AVAILABLE ONLY IN DR20 AND FRM10 SERIES

AVAILABLE ONLY IN DR20 AND FRM10 SERIES

1

2 4

3 3

X

OP.

X1

X2

N.A. = NORMAL AFTER

X

XO

X

+1

9 10

11 12

2

5 6

8 7

X

O

CCL.

OP.

45°

45°

XX

CN.A.CL.

CL. X

X

1

2

X

4

3 3

X

OP.

CL.

X1

X2

0C

X

X

X

3

9 10

12 11

X

X

2

5 6

8 7

4

13 14

16 15

X

X

5

17 18

20 19

X

X

6

21 22

24 23

X

X

7

25 26

28 27

X

X

8

29 30

32 31

X

X

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

X

OP.

CL.

X1

X2

0C

X

X

X

3

9 10

11 12

XX

2

5 6

8 7

4

13 14

16 15

X

X

5

18 20

19 19

6

21 22

24 23

7

25 26

27 28

8

29 30

32 31

O

CCL.

OP.

45°

45°

1

2

X

4

3 3

2

X

IA.

IC.

X1

X2

A

C

X

X

5 6

8 7

C

45°

45°

X

X

A0

IA IC

0

X

1

2

X

4

3 3

X

IA.

IC.

X1

X2

A

C

X

X

C

45°

45°

A0

IA IC

0

X

3

9 10

12 11

X

X

2

6

X

8

7 7

XX

X

X

X

X

1

2

X

4

3 3

X

OP.

CL.

X1

X2

0C

X

X

X

3

9 10

12 11

X

X

2

6 8

7 7

4

13 14

16 15

X

X

5

17 18

20 19

X

X

6

21 22

24 23

X

X

7

25 26

28 27

X

X

8

29 30

32 31

X

X

O

CCL.

OP.

45°

45°

XXX

X

X

X

XXXX

X

X XX

X

X

X

X

XX

X X

N.A. OP.

N.A. = NORMAL AFTERN.A. = NORMAL AFTER

Page 16: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

14 www.comeletric.it

Lamps

W ordering code

BA9s Bayonet Socket Incandescent type.

mAVoltage

110V

125mA 3W24V

130V

220V

60mA

50mA

6mA

6W

6W

3W

1380/24

1380/110

1380/130

1380/220

Colour Available: Incandescent

W ordering codemAVoltage

48Vdc

15mA 0.4W24Vdc

110Vdc

130Vdc

220Vdc

14mA

10mA

10mA

6mA

0.7W

1.1W

1.3W

1.3W

1410/24Colour

1410/48Colour

B=White

G=Yellow

R=Red

V=Green

W ordering codemAVoltage

48V

100mA 3W24V

60V

40mA

40mA

2W

2.5W

0250/24-3

0250/48-40

0250/60-40

W ordering codemAVoltage

15mA 0.4W

14mA

10mA

10mA

0.7W

1.1W

1.3W

B=White

G=Yellow

R=Red

V=Green

W ordering codemAVoltage

48V

50mA 1.2W24V

40mA 2W

W ordering codemAVoltage

15mA

14mA

B=White

G=Yellow

R=Red

V=Green

W ordering codemAVoltage

20mA 0.2W2.1V

G=Yellow

R=Red

V=Green

BA9s Bayonet Socket LED type:

BA7s Bayonet Socket Incandescent type. BA7s Bayonet Socket LED type:

T5.5 Telephone Bulb incandescent type:

Rectangular LED 2.5 x 7 mm.

Discrepancyswitch Series:

FRM10DR20

Discrepancyswitch Series:

FRM 10DR20

Discrepancyswitch Series:

Discrepancyswitch Series:

FRMM 6FRMM 6 IP20

Discrepancyswitch Series:

Discrepancyswitch Series:

Discrepancyswitch Series:

FRMM 6FRMM 6 IP20

FRMM 2000 Model M201

FRMM 2000 Model M201

FRMM 2000 Model M202

Incandescent

Incandescent

T5.5 Telephone Bulb LED type:

0.4W

0.7W

48Vdc

24Vdc

110Vdc

130Vdc

48Vdc

24Vdc

Code: 1128

Extractor for Lamps BA9s Extractor for Lamps BA7s

Code: 0051

Colour Available:

Colour Available:Colour Available:

Colour Available: Colour Available:

Colour Available:

1410/110Colour

1410/130Colour

1410/220Colour

0258/24Colour

0258/48Colour

0258/110Colour

0258/130Colour

0243/24-50

0243/48-40

0249/24Colour

0249/48Colour

2132/Colour

Page 17: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

15www.comeletric.it

Standard Escutcheon Plate Ordering

-Escutcheon plate coding

1 3

M

2

3

2 Positions

1 n° Escutcheon Plate shape.

2 n° Escutcheon Plate Dimensions.

20002

0

1 C

W

Z

T

C

OU

V.

FERME'

TRIP

CLOSE

30012

0 0CH. AP.

0CL. OP.AP. CH.

0OP. CL.

0TRIP CLOSE

20256 20264 20299 20584 20585 20586 20587 20588 20589

20590 20022 20001 20591 20592 20593 20594

30065 30024 30667 30154 30021 30140 30052 30010 30186

A

C

O

CH.

AP.

CLOSE

OPEN

F

O

OP.

CL. 0

1

A

C

AP.

CH.

OP.

CL.

O

F

20488

0

CE

I

0OPEN CLOSE

0APRE CHIUDE

.0 I

0A C

0OUVRE' FERME'

40043

C

A

IC

IA

40044

C

O

IC

I0

40058

I

E

II

IE

40059

I

0

40060

ON

OFF

CL.

OP.

40079

C

A

MC

MA

40094

C

0

SC

S0

40097

C

A

CH.

AP.

40103

C

O

CL.

OP.

40126

F

O

IF

I0

40252

1

0

CH.

AP.

40121

1

0

CL.

OP.

40095

CTRL

OFF

40175

C

O

ON

CTRL

ON

OFF

CMD

O

C

CMD

40127

F

0

FERME'

OUV.

40156

Z

W

ZI

WI

40088

A

C

IA

IC

40253 40254 40257

40258

CC

OC

40227

C

T

TC

TT

40256

PUSH

CLOSE

TRIP

40259 40255

E

A

EB

AB

O

C

IO

IC

E

I

IE

II

O

C

OP.

CL.

CL.

OP.

PU

SH

PUSH

CLOSE

OPEN

PU

SH

20595

E

A

3 Positions

4 Positions

40260

ON

OFF

CLOSE

TRIP

The Escutcheon plate is strictly necessary for fitting the switch to the panel , if none engraving is specified , the frontplate will be supplied Blank , code 00000.The engraving listed below, are only a little part of those available, require the code of the needed one if not present below.

This code is referred to the shape of the Frontplate.

The M letter stands for the Discrepancy switch's frontplate.

MQ = SQUARE ESCUTCHEON PLATE Circuit Breaker control.

MT = ROUND ESCUTCHEON PLATE Disconnector Switch control.

This code is referred to the dimensions of the Frontplate.

The dimension is referred to the type of discrepancy switch it is mounted on and it is indicated in the reference catalogue.

Page 18: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

16 www.comeletric.it

Discrepancy Switch Series :

CB D

H FG

A E

Form for special diagram

0

180

315

270 90

45

135225

Position Engraving

EngravingPosition

FRMM 6

Specifications......................................................................................

Contacts

Positions

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

A B C D E F G H

Lock in Pos.

Notes.

Accessories

Model number:

Ordering Code : (it will provided by COMELETRIC)

Square Front plate

Round Front plate

Gilded Contacts

Led Lamp

Voltage of lamp ........................................................................................

Opaline handle

Mosaic Tile Mounting(specify the tile brand and size)

Special Colour of Lamp(specify the colour)

.........................................................................................................

FRMM 6 IP20

FRMM 2000

ABCDEFGH

FRM10 DR20

.........................................................................................................

Page 19: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

17www.comeletric.it

Legenda

XX

X

XX

XMaintained action contact(the contact closes in the X pos. and maintains the action for the length of the arrow).

Make before break overlapping contacts ( without current breaking ).

Closed contact without current breaking

Closed contact

Spring return position.

Spring return from left and from right position.

Contact presence.

Terminal marking

1

Packet indication

1 2

3 4

Jumpers.When the connected terminals have the same number , the jumper is internal.

1 3

2 2

Jumpers. When the connected terminals have different numbers, the jumper is external and will not be suppliedby COMELETRIC.

1 2

3 4

Lamp. HORIZONTAL MOUNTINGFor obtaining the shown movement the switchhas to be mounted in horizontal.The front plate will be engraved for having the right positions.

Page 20: Discrepancy Switches - Control Discrepancy Switches Standard Electrical Diagrams

Via E. Rizzi 13/H - 20077 Melegnano (MI) - ITALYTel. +39 02 98119791Fax +39 02 98119825E-mail: [email protected]

UNI EN ISO 9001/2008 IEC-EN 60947

DIA

-DS

01

/13