SPECIALIST VENTILATION SERVICES Ltd ). Specialist Ventilation Services Ltd . INNOVATIVE AIR CONTROL Displacement Ventilation Terminals. for Commercial & Industrial Buildings. Our range of specialist Displacement Terminals are designed to satisfy the demands of modern buildings in terms of performance and Architectural requirements. Our bespoke Terminals can be constructed from a range of metals as well as other materials including Natural wood, MDF or Specialist Plastics.

Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

SPECIALISTVENTILATIONSERVICES Ltd

).

Specia l i s t Vent i la t ion Serv ices Ltd. INNOVATIVE AIR CONTROL

Displacement Ventilation Terminals. for Commercial & Industrial Buildings. Our range of specialist Displacement Terminals are designed to satisfy the demands of

modern buildings in terms of performance and Architectural requirements.

Our bespoke Terminals can be constructed from a range of metals as well as other

materials including Natural wood, MDF or Specialist Plastics.

Page 2: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

SPECIALISTVENTILATIONSERVICES Ltd

Gala Theatre: Durham City

Displacement Ventilation Overview Displacement ventilation is a fairly simple but effective and very efficient method of ventilation utilising the buoyancy of thermal activity given off from people, machines and countless other forms of heat sources. As low level air in a space warms due to the contact of a warm surface it will naturally start to rise to high level because if its buoyancy. This in turn creates an area of negative pressure at low level which pulls surrounding air towards the heat source and the cycle continues like this for as long as there is a heat source in contact with the air. Without any form of ventilation this cycle will continue rising to high level, then cool down and begin falling back to low level creating a circulation of air. If there is an excess of heat sources at low level then this will soon build up the room temperature from the ceiling down to low level, perhaps causing discomfort to the occupants or affecting the processes in the space.

Queen Elizabeth Hospital: Gateshead.

The area of low level where the activity of personnel, processes or machines etc is commonly known as the “Occupied Zone” typically 2m high. This is generally where complaints are received and as a result ventilation is required.

How they work….. Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the introduction of fresh air directly into the occupied zone we no longer get the circulation cycle as described above. What we achieve is displacement of the warm and or contaminated air to high level where it will be removed rather than cooling naturally and falling back down into the occupied zone. This is gives a much better air quality and temperature control at low level where it matters.

Durham University

ADVANTAGES Displacement Ventilation is advantageous in this situation due to the following factors; HIGH EFFICIENCY Natural buoyancy of the warm air stratifies to high level from the occupied zone where it can be removed efficiently without the need for cooling it unlike a mixing ventilation system for example.

Page 3: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

Newcastle University

HEAT RECOVERY As the warm air has not been cooled then the potential for heat recovery from the warm or even hot air is far greater than any other form of ventilation. NATURAL EXHAUST If heat recovery is not necessary then natural exhaust terminals can be used without the need for electrically powered fan systems and controls.

LOW ENERGY Due to the fact that the air is introduce at low velocity into the occupied zone it minimises the need for air conditioning resulting in lower air volumes and fan sizes.

SPECIALISTVENTILATIONSERVICES Ltd

REDUCED AIR FLOW Generally factories, spots halls, shopping centres and car show rooms etc all have reasonably high internal spaces. This means that there is a very high volume of air to treat whether it is heating or cooling and this is more often than not done using some form of ventilation. Displacement ventilation is much more efficient in these applications particularly when there is a potential for high heat gains in the occupied zone. The reason being is that the design of displacement ventilation systems focuses on the occupied zone with little consideration to the high level when dealing temperature or contaminant based issues. The result therefore is greatly reduced airflow requirements to satisfy the demand of the occupied zone compared to the entire volume of the space. BETTER AIR QUALITY Because all the fresh air is introduced directly into the occupied zone the air quality is far better than that of a typical high level mixing system. An additional benefit is that due to the fact that the entire fresh air volume travels through the occupied zone it means that the air change rate in the occupied zone is much higher compared to the rest of the space.

Queen Elizabeth Hospital: Gateshead.

Page 4: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

Width (W)

Depth (D)

NominalSpigot Dia

Min 50

Ctr =1/2 (D)Height (H)

40Spigot Dia

Dimensions: (mm)

DTC - Circular

Width (W)

Depth (D)

NominalSpigot Dia

Min 50

Ctr =1/2 (D)

Height (H)

Dimensions: (mm)

40Spigot Dia

DTD - "D" Shape

Width (W)

Depth (D)

Height (H)

40Spigot

Dimensions: (mm)

Nominal size

DTD-F Flat "D"

RemovableLid.

Length (L)

Rectangular or Circular supply air spigot to suitairflow requirements.

100

Open End(Modular Units)

Width (W)

DTD-CM Ceiling Mounted Dimensions: (mm)

Unit Size Width (W) Depth (D) Length (L) Spigot Size

500 500 250 600 - 2000

600 600 300 600 - 2000

700 700 300 600 - 2000

750 750 300 600 - 2000

900 900 300 600 - 2000

1000 1000 300 600 - 2000

1000-4 1000 400 600 - 2000

1100 1100 400 600 - 2000

1200 1200 400 600 - 2000

Depth (D)

450 450 250 600 - 2000

400 400 250 600 - 2000

300 300 250 600 - 2000

VENTILATION

SERVICES Ltd

Displacement Terminal types & dimensions

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

300400450500/1500500/2000600700800900

300400450500500600700800900

300400450500500600700800900

125012501500150020002000240024003000

150-200200-315250-350300-400300-400400-500500-630600-710700-800

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

300400450500/1500500/2000600700800900

300400450500500600700800900

300400450500500600700800900

125012501500150020002000240024003000

150-200200-315250-350300-400300-400400-500500-630600-710700-800

Unit Size Width (W) Depth (D) Height (H) Spigot Size

500 500 200 900 300 x 100

600 600 200 900 400 x 100

700 700 300 1250 400 x 200

750 750 250 1250 500 x 150

850 850 350 1800 500 x 250

900 900 300 1800 600 x 200

1000-6 1000 400 2000 600 x 300

1000-7 1000 300 2000 700 x 200

1100 1100 400 2000 700 x 300

1200 1200 400 2000 800 x 300

1300 1300 500 2500 800 x 400

1400 1400 400 2500 1000 x 300

1600 1600 600 2500 1000 x 500

Page 5: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

Dimensions: (mm)

DTR - Rectangular

VENTILATION

SERVICES Ltd

Displacement Terminal types & dimensions

Width (W)

Depth (D)

NominalSpigot Dia

Min 50

Ctr =1/2 (Dia)+50

Height (H)

Dimensions: (mm)

40Spigot Dia

300400500500600700800900960

125012501500200020002000240024002400

100-160200-250250-315300-315300-400400-500450-560500-630600-710

300400500500600700800900960

DTQ - Quadrant

Width (W)

Height(H)

Depth(D)

Spigot Dia(or rectangular size)

50

50

Rectangular Spigot(option)

50

Width (W)

Height(H)

Depth(D)

Spigot Dia(or rectangular size)DTS - Square

Dimensions: (mm)

DTS-3 illustrated

DTR-1 illustrated

300400500/1500500/20006007008009001000

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

500 500 300 1000 200

600 600 350 1000 250

700 700 400 1250 300

800 800 400 1500 315

900 900 500 1800 350

1000 1000 500 2000 400

1250 1250 500 2400 600 x 400

1400 1400 500 2900 800 x 400

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

500 500 500 1000 400

600 600 600 1000 500

700 700 700 1250 600800 800 800 1500 700

900 900 900 1800 800

1000 1000 1000 2000 900

1250 1250 1250 2400 1000 x 1000

1,2,3,4 Active sides

1,2,3,4 Active sides

Page 6: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

Dimensions: (mm)

VENTILATION

SERVICES Ltd

Displacement Terminal types & dimensions

Width (W)

Height (H)

Dimensions: (mm)

40Spigot Dia

300 400 500 600 700 800 90010001200

125012501500150018002000200024002400

150180200250300350400450500

285350425495565640715780925

DTW - Wall Mounted

300 400 500 600 700 800 90010001200

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

Unit Size Width (W) Depth (D) Height (H) Spigot Dia

500 500 300 1000 200

600 600 350 1000 250

700 700 400 1250 300800 800 400 1500 315

900 900 500 1800 350

1000 1000 500 2000 400

1250 1250 500 2400 600 x 400

1400 1400 500 2900 800 x 400

A

Height (H)

Width (W)Spigot Positions

Width Active

Depth (D)

Section A-A

DTT - Triangular

25

Min 35

Depth (D)

Width (W)

DTW-R

GrabberCatches(44 Nm)

Section A-ALower retainingbracket fixed tofront panel.

RemovableFront Panel.

Recessed Frame

Plenum

Optional accoustic foam

GrabberCatches(44 Nm)

Section A-A

DTW-F

30mmFace Flange

Plenum

Plenum

RemovableFront Panel.

35

See below for front panel options.

Aperture(H) + 5(W) + 5

75

Page 7: Displacement Ventilation Brochure. · 2020. 2. 14. · Displacement Ventilation makes use of the buoyancy of the warm air convective plumes rising to high level, however with the

SPECIALISTVENTILATIONSERVICES Ltd

).

Special ist Ventilation Design Services.

Specialist Ventilation Services Ltd have been providing Design

assistance and technical support to the Building Services Industry and Mechanical Consulting Engineers since our incorporation in 1998. We have been offering a full design and selection service for our comprehensive range of ventilation products and are proud to represent some of our more specialist suppliers who are the market leaders in their field.

Our main area of expertise is the design & manufacture of bespoke ventilation products and systems to suit our clients specific requirements. We focus on high efficiency products and systems to enable our clients to achieve as minimum an environmental impact as possible using low energy consumption products and innovative system designs.

These can vary from complete turnkey specialist packages, to the supply only of basic products. We aim to offer a service which represents value for money as well as being a high quality technically evaluated solution.

From our Head Office and factory in County Durham we cover the whole of the UK and Ireland.

Head Office: Specialist Ventilation Services Ltd. Unit 3, Greencroft Industrial Park, Annfield Plain, Stanley, County Durham, DH9 7YB Tel: 01207 529333 Fax: 01207 529444 E-mail: [email protected] Website: www.SpecialistVentilation.com

Special ist Ventilation Products.

Kitchen Ventilation Canopies, Ceilings, Service Spines & Gas Interlocks.

Odour Control systems, UV & Ozone.

Natural Ventilation Wall / Window units and High Performance Roof Terminals.

Fabric Duct systems.

Displacement Ventilation Terminals.

Fire, Smoke & Insulated Dampers.

Smoke and Ventilation Control Panels.

Fire & Smoke activated Transfer Grilles.

Louvre Screens, Grilles & Diffusers.

Stainless Steel ventilation components and accessories.

Prison Grilles, and other Security or Vandal resistant products.

Laboratory Extract Benches, Bench Extract units, Laminar Flow units, HEPA Filter Grilles & Containment Hoods.

Fire Rated Wall, Ceiling, Transfer Grilles & Plenums