2
Athermal AWG DWDM Module Specifications Parameter Unit Min Max Channels 40 Channel Spacing GHz 100 Nominal Center Frequencies THz 192.00 195.90 Clear Pass Band nm ±0.1 Center Wavelength Accuracy pm -50 50 Filter Bandwidth @ -1.0dB nm 0.36 Filter Bandwidth @ -3.0dB nm 0.51 Adjacent Channel Crosstalk dB -25 Non-Adjacent Channel Crosstalk dB -30 Total Integrated Crosstalk dB -21 Insertion Loss dB 1 6.0 Insertion Loss Uniformity dB 1.0 Insertion Loss Ripple dB 0.75 Polarization Dependent Loss dB 0.5 Directivity dB -40 Return Loss dB -40 Chromatic Dispersion ps/nm -20 20 Notes: 1.Including 1connector. Features 4 4 4 4 4 40 channels x 100GHz Mux/Demux 44 channel option available Fully passive module Low insertion loss and PDL Low crosstalk, high uniformity Applications 4 4 4 4 Long haul DWDM system Metro DWDM system Access/Enterprise network Test instrument DWDM Wuhan Flexlink Technologies Co.,ltd www.flxlink.com

DWDM Athermal AWG DWDM ModuleAthermal AWG DWDM Module Specifications Parameter Unit Min Max Channels 40 Channel Spacing GHz 100 Nominal Center Frequencies THz 192.00 195.90 Clear Pass

  • Upload
    others

  • View
    18

  • Download
    0

Embed Size (px)

Citation preview

Athermal AWG DWDM Module

Specifications

Parameter Unit Min Max

Channels 40

Channel Spacing GHz 100

Nominal Center Frequencies THz 192.00 195.90

Clear Pass Band nm ±0.1

Center Wavelength Accuracy pm -50 50

Filter Bandwidth @ -1.0dB nm 0.36

Filter Bandwidth @ -3.0dB nm 0.51

Adjacent Channel Crosstalk dB -25

Non-Adjacent Channel Crosstalk dB -30

Total Integrated Crosstalk dB -21

Insertion Loss dB 16.0

Insertion Loss Uniformity dB 1.0

Insertion Loss Ripple dB 0.75

Polarization Dependent Loss dB 0.5

Directivity dB -40

Return Loss dB -40

Chromatic Dispersion ps/nm -20 20

Notes: 1.Including 1connector.

Features

4

4

4

4

4

40 channels x 100GHz Mux/Demux

44 channel option available

Fully passive module

Low insertion loss and PDL

Low crosstalk, high uniformity

Applications

44

4

4

Long haul DWDM system

Metro DWDM system

Access/Enterprise network

Test instrument

DWDM

Wuhan Flexlink Technologies Co.,ltd www.flxlink.com

DWDM

Wuhan Flexlink Technologies Co.,ltd www.flxlink.com

DWDM

ConfigurationChannel

Space

Exp.

Port

Channel

Type

Channel

Number

First

Channel

Fiber

typePackage

Pigtail

Type

Pigtail

LengthConnector

Configuration M=Mux, D=DeMux, M&D=Mux and DeMux

Channel space 50G, 100G, 200G

Exp. Port E= Yes, 0= None

Channel Type A=Athermal AWG, T=Thermal AWG, D=Filter DWDM

Channel Number 1=1ch, 2=2ch, ... 47=47ch, 48=48ch

First Channel C1=1577.03, C2=1576.20, ... ... C71=1521.02, C72=1520.25

Fiber Type

Package B=Stainless

Pgitail Type 0.25=250μ 0.9=900 μm, 2.0=2.0mm, 3.0=3.0mm, 0=Adaptor

Pigtail Length 0.1m=0.1m,... 1.5m=1.5m,...10m=10m, (Defined as request), 0=Adaptor, X=others

ConnectorFU=FC/UPC, FA=FC/APC, SU=SC/UPC, SA=SC/APC, ST=ST/UPC, LU=LC/UPC, LA=LC/APC,

FU/FA=input FC/UPC + ouput FC/APC, 00=None, X=Others

steel tube; D=Plastic box; L=LGX box;H=Aluminumbox; U=Rack mount; X=Customized package

m,

GD=G652D, GA1=G657A1, GA2=G657A2

Ordering Information: