SUMMARY

TOPIC 1: Theory on WDM Networks

TOPIC 2: Parameters of WDM Networks

TOPIC 3: Materials for Deployment

TOPIC 5: Technical Documentation

TOPIC 6: Commissioning of DWDM Routes

TOPIC 7: Testing of DWDM Systems

TOPIC 8: Update Software

TOPIC 9: Managing Network Elements

TOPIC 10: Step by Step (MOST IMPORTANT)

TOPIC 4: Theory About Products

TOPIC 11 ITU-T Recommendation

Page 3: DWDM Training 1

TOPIC 1: Theory on WDM Networks

WDM meansWavelength Division Multiplexing

CWDM – Coarse Wavelength Division Multiplexing- Spacing of 20nm - A 1620nm 1260nm band - Maximum capacity of 16 channels / lambda

DWDM – Dense Wavelength Division Multiplexing (Até 160 Lambdas)

- Spacing of 0.80 nm (100GHz) or 0.40 nm (50GHz) - Bands from 1529.16 nm to 1603.57 nm (Band C Band

and L) - Maximum capacity of 160 channels / lambda

Band C (from 1529.55 nm to 1560.61 nm)

Page 4: DWDM Training 1

OTU Optical Transponder UnitOA Optical Amplifier (Amplificador)MUX/DEMUX Multiplexing/Demultiplexing UnitOSC Optical Supervisory Channel (1510nm)

O S C

TOPIC 1: Theory on WDM Networks

Converter“OTU”

SDHSTM1/4/16/64

ROUTERIP

ATM(OUTROS)

SDHSTM1/4/16/64

ROUTERIP

ATM(OUTROS)

Converter“OTU”

OA

WDM system

Page 5: DWDM Training 1

MUX

MUX

OTUOTU

OTUOTU

OTUOTU

OTUOTU

OTUOTU

OTUOTU

DEMUX

DEMUX

FIU

FIU

OA

OSC OSC

OTUOTU Transponder

MUX

MUX

Multiplexer

OSC Supervisory Channel

OA Optical Amplifier

DEMUX

DEMUX

Demultiplexer

FIU

Line Inteface

OA

Supervisory Channel / 1510nm

Channels in Bands“C” 1525nm a 1565nm

Sinal SDH

OA

OTUOTU

OTUOTU

OTUOTU

MUX

MUX

DEMUX

DEMUX

OTUOTU

OTUOTU

OTUOTU

OA

STATION "A" STATION “B"

TOPIC 1: Theory on WDM Networks

Page 6: DWDM Training 1

TOPIC 1: Theory on WDM Networks

Types of Elements in WDM Network

Page 7: DWDM Training 1

TOPIC 2: Parameters of WDM Networks

Documentation Summary

1. Types of Plates. Amplifiers, DCM modules, multiplexers, transponders, etc.

2. Parameters.Distance, attenuation, fiber type, OSNR, PMD, etc..

Page 8: DWDM Training 1

TOPIC 2: Parameters of WDM Networks

Important parameters

Attenuation Curve

Chromatic Dispersion

dispersion PMD

bands available

Page 9: DWDM Training 1

TOPIC 2: Parameters of WDM Networks

Important parameters

Signal to Noise (dB)obtained with the OSA

Distance (km), obtained with OTDR

Page 10: DWDM Training 1

TOPIC 3: Materials for Deployment

1. Fixed Attenuators type : 2dB, 5dB, 7dB e 10dB

2. Optical CordsA. LC/PC LC/PCB. LC/PC FC/PC

3. Power MeterMaximum input power : +10dBmsensibility : -60dBmWavelength : 1310nm e 1550nm

4. Fiber Cleaner

5. OSA – Spectrum analyzer

Tools / Materials Required for Deployment

Page 11: DWDM Training 1

TOPIC 3: Materials for Deployment

1. NoteBook More than Memory 512MB

2. SoftwareU2000 WebLCTNavigatorHost

3. Ethernet Cable 6. scissors direct

crossed4. Crimpador

7. Labelling

5. analyzers

Tools / Materials Required for Deployment

Page 12: DWDM Training 1

TOPIC 4: Theory About Products

OTU Plates

STM-1/4/16

LWM

1525nm a 1565nm(Canal: 2,5Gbps)

LWX

Arbitrary Bit Rate (34Mbps~2.7Gbps)

LDG

LBE

LOG

2xGE

10GbE LAN

8xGE

1525nm a 1565nm(Canal: 2,5Gbps)

1525nm a 1565nm(Canal: 2,5Gbps)

1525nm a 1565nm(Canal: 10Gbps)

1525nm a 1565nm(Canal: 10Gbps)

LWF

STM-16

STM-64

LWC

1525nm a 1565nm(Canal: 2.5Gbps)

1525nm a 1565nm(Canal: 10Gbps)

TMX 4×STM-16

1525nm a 1565nm(Canal: 10Gbps)

LQG4 x GE

1525nm a 1565nm(Canal: 5Gbps)

LRF

STM-64

STM-64

TRCSTM-16

TMR

SINAL DIGITAL

SINAL ANALÓGICO

1525nm a 1565nm(Canal: 10Gbps)

1525nm a 1565nm(Canal: 2.5Gbps)

1525nm a 1565nm(Canal: 10Gbps)

LWMR

1525nm a 1565nm(Canal: 2.5Gbps)STM-1/4/16

LWXR

1525nm a 1565nm(Canal: 2.5Gbps)

Arbitrary Bit Rate (34Mbps~2.7Gbps)

Page 13: DWDM Training 1

TOPIC 4: Theory About Products

Multipexors/Demultiplexors Plates

M401525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

Sinal Concatenado

D401525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

Sinal Concatenado

V401525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

Sinal Concatenado

40 x eVOA

MR4

1525nm a 1565nmADD/DROP10Gbps/2.5GbpsAté 4 Canais

MR2

1525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

1525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

1525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

1525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

1525nm a 1565nmADD/DROP10Gbps/2.5GbpsAté 2 Canais

FIU

1525nm a 1565nm10Gbps/2.5GbpsAté 40 Canais

1505nm a 1515nmCanal de Supervisão

Sinal ConcatenadoCom Canal deSupervisão

Page 14: DWDM Training 1

TOPIC 4: Theory About Products

Amplifier boards OSN6800

OBU1525nm a 1565nm1525nm a 1565nm

OPU1525nm a 1565nm1525nm a 1565nm

OAU1525nm a 1565nm1525nm a 1565nm

DCM/LOOP

HBA1525nm a 1565nm1525nm a 1565nm

Item

Maximum Output Power of

Full Wavelengths

(dBm)

Maximum Output Power of

Single Wavelengths

(dBm)

Channel

Gain(dB)

Typecial Input Power of Single

Wavelength(dBm)

Minimum Input Power(dBm)

Noise Figure(dB)

Price Remark

OBU101 16 0 20 -20 -32 4,5 1  

OBU103 20 4 23 -19 -32 4,8 1,4  

OBU104 16 0 17 -17 -32 5,5 1,1  

OBU205 23 7 23 -16 -24 7 1,8  

OAU101 20 420 ~

31-27 ~ -16 -32 5.0~7.7 2  

OAU102 17 120 ~

31-30 ~ -19 -32 5.5~7.3    

OAU103 20 424 ~

36-32 ~ -20 -32 5.0~6.6 2,1  

OAU105 23 723 ~

34-27 ~ -16 -32 5.4~7.7 2,6  

HBA 26 10 29 -19 -25 8    

CRPC NA NA 10 -40 ~ -30 NA -1,5 4,1  

Page 15: DWDM Training 1

TOPIC 4: Theory About Products

Magnifying Plates - UCO

INOUT

MON (-20)

TDC RDC

1 2 3 45PA BA

EVOA

OAU

Page 16: DWDM Training 1

Absolute Power x Power Surge Channel The absolute power in the common points of multiplexed channels varies in accordance with the number of channels. This approach is represented by the following formula :

Pabs(dBm) = Pch(dBm) + 10 x log(Nch)onde:Pabs(dBm) Absolute Power (measured by power meter or T2000)Pch(dBm) Peak power of the channel (measured with OSA)Nch Number of Channels Trecho.

Exemplo Real: During deployment of the stretch between HDPE and SPO-

BRE-TRM was measured using the management T2000 power values described below in Figure

Using as starting input power station SPO-IPCC calculating the peak power of channel would be:

-18,60dBm = Pch(dBm) + 10 x log (2)Pch(dBm) = - 21,60dBm

On receipt of SPO-IPCC is a UFO. According to manufacturer the peak power channel to be-22dBm ± 1dB.

TOPIC 4: Theory About Products

Page 17: DWDM Training 1

TOPIC 5: Technical Documentation

Technical Documentation

Commissioning Table – Table Commissioning

Design Documents – Fibers diagram

General Documentation

Diagrama de Fibras

Tabela de Comissionamento

Documento Geral Documento Geral

Acceptance ProtocolProtocolo de

Aceitação

Page 18: DWDM Training 1

TOPIC 6: Commissioning of DWDM Routes-3dBm

-9dBm

-19dBm

+4dBm

+3,5dBm

Measures Per Channel

-16dBm

-22dBm

+4dBm

-3dBm

-6 a -10dBm

-5dBm

>-38dBm

Page 19: DWDM Training 1

TOPIC 7: Testing of DWDM Systems

Power Meter

check :1. Maximum input power.2. Wavelength Test?3. Type connector.

SDH analyzer Ethernet analyzer

Check:1. Powers TX and RX 2. mapping STM1/4/16/64)3. Type connector. 4. Activation of Lasers5. Tests 15minutos per plate / door.

Verificar:1. Execução da Norma RFC25442. Tipos de Conectores.3. Ativação de Lasers4. Configurar CROSS para LOG(S)

Page 20: DWDM Training 1

TOPIC 7: Testing of DWDM Systems

OSA – Optical Spectrum Analyzer

check:1. Maximum input power.

2. Type connector.

3. configuration - Spectrum between 1525nm - 1565nm - OSNR with resolution (0.1mm)?4. save Results - Wavelength - power surge - signal to noise ratio(OSNR)

Page 21: DWDM Training 1

TOPIC 8: Update Software

Software Update

OptiX IManager T2000 - Toolkit

OptiX Navigator

Technical Documentation / Software

Page 22: DWDM Training 1

TOPIC 8: Update Software

Technical Documentation

Matching Table is the table that describes all the software of all cards DWDM product. This table should be used as referênia to perform software updates.

The software product WDM plates are defined by the software controller card (SCC or SCE).

For this course we will adopt the most current software from Huawei, which are:

OSN6800 – Software 51.05.35

NOTE: ALL SHOULD BE REQUIRED A SOFTWARE HUAWEI AND STORED IN SECRECY ON BEHALF OF COPYRIGHT.

Page 23: DWDM Training 1

TOPIC 9: Element Management

Data Management

Types of Cables

direct

crossed

IP Addresses

IP: 129.9.x.xmask : 255.255.0.0Gateway: 0.0.0.0

Physical Connection

Gateway

Affiliates

Page 24: DWDM Training 1

TOPIC 10: Step by Step

1. Being with All Papers Printed2. Assembly of fibers in equipment.

Follow Diagram fibers supplied by Huawei.

3. InventoryFill the table of Commissioning

1. Internal fiber labelingFill the table of Commissioning

1. Configuration IDFollow List ID provided by Huawei.1. SSE1SCC01:

Convert Decimal to Binary.First Dip Switch 4 position always 0.According depends Dip Switch ID (8 positions)Third ID depends on the Dip Switch (8 positions)

SSE2SCC01 Using the T2000 or Navigator to exchange ID.

Core Materials::

- - Loop (LC / PC <> LC / PC)

- - Attenuator 2dB, 5dB, 7dB and 10dB- Starter Kit fiber    LC-PC <> FC / PC (15m) - qtd: 10    LC-PC <> SC / APC (15m) - qtd: 10    LC-PC <> E2000/APC (15m) - qtd: 10    LC-PC <> LC-PC (3m) - qtd: 10    LC-PC <> LC-PC (10m) - qtd: 10- Power Meter- OSA - adjusted pursuant / Calibration- Cletop / Lenco - Limpar

Table of Channels - BWS1600G

Page 25: DWDM Training 1

TOPIC 10: Step by Step

6. NE Criar no T2000. IP notebook: 129.9.0.12 – Mask: 255.255.0.0 T2000 User : admin – Senha: T2000 Usar “Manual Configuration” to create.

7. Enable / Flirt Laser Enable give laser plates and SC1/SC2 OTU

8. configure OSA

9. Mediate Set CommissioningCommissioning measures.

Attending to the amplifier input power (measured with OSA)Attending to the amplifier output power (measured with OSA)Table Send to Commissioning Manager.

10. Check with Alarm T2000

11. Skip Fiber between OTU and DGO

12. label.

13. Tag standards

Table of Channels - BWS1600G

Etiquetas

Page 26: DWDM Training 1

TOPIC 11: ITU-T Recommendation

Frequency Lambda Channel Frequency Lambda Channel(THz) (nm) M40/D40 (THz) (nm) M40/D40192.1 1560,61 40 194.1 1544,53 20192.2 1559,79 39 194.2 1543,73 19192.3 1558,98 38 194.3 1542,94 18192.4 1558,17 37 194.4 1542,14 17192.5 1557,36 36 194.5 1541,35 16192.6 1556,55 35 194.6 1540,56 15192.7 1555,75 34 194.7 1539,77 14192.8 1554,94 33 194.8 1538,98 13192.9 1554,13 32 194.9 1538,19 12193.0 1553,33 31 195.0 1537,40 11193.1 1552,52 30 195.1 1536,61 10193.2 1551,72 29 195.2 1535,82 9193.3 1550,92 28 195.3 1535,04 8193.4 1550,12 27 195.4 1534,25 7193.5 1549,32 26 195.5 1533,47 6193.6 1548,51 25 195.6 1532,68 5193.7 1547,72 24 195.7 1531,90 4193.8 1546,92 23 195.8 1531,12 3193.9 1546,12 22 195.9 1530,33 2194.0 1545,32 21 196.0 1529,55 1

40 Channels Informations 40 Channels Informations

Table of Channels - ONS6800