6
EAVES AND LOW LEVEL VENTILATION SYSTEMS CI/SfB (47) Uniclass L529 March 2015 G lidevale eaves ventilation systems have been designed to provide a range of solutions to introduce low level ventilation into roofspaces in an unobtrusive way. There are two primary methods of introducing the ventilation at low level either via the soffit in discrete units or continuous systems using the SV soffit range or over the fascia in continuous systems using the FV fascia range. All provide full compliance with BS 5250 Control of Condensation in Buildings, the primary means to comply with Building Regulations in the UK as well as providing driving rain and large insect resistance. Once inside it is important that the ventilation air actually reaches all parts of the roofspace to be able to remove high humidity air and reduce the risk of harmful condensation from forming. To ensure this occurs the RV rafter trays are available in a range of styles to suit numerous applicatons and are designed to ensure a clear unobstructed path from SV or FV ventilators to the roofspace. ........................

EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

EAVES AND LOW LEVEL VENTILATION SYSTEMS

CI/SfB (47) Uniclass L529March 2015

Glidevale eaves ventilationsystems have beendesigned to provide a range

of solutions to introduce low levelventilation into roofspaces in anunobtrusive way.

There are two primary methods ofintroducing the ventilation at low leveleither via the soffit in discrete units orcontinuous systems using the SV soffitrange or over the fascia in continuoussystems using the FV fascia range. All provide full compliance with BS 5250Control of Condensation in Buildings, theprimary means to comply with BuildingRegulations in the UK as well as providingdriving rain and large insect resistance.

Once inside it is important that theventilation air actually reaches all parts ofthe roofspace to be able to remove highhumidity air and reduce the risk of harmfulcondensation from forming. To ensure thisoccurs the RV rafter trays are available in arange of styles to suit numerousapplicatons and are designed to ensure aclear unobstructed path from SV or FVventilators to the roofspace.

. . . . . . . . . . . . . . . . . . . . . . . .

Page 2: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description, ApplicationsFV Fascia Ventilators are an unobtrusivemethod of providing ventilation in a range ofeaves details, including those without aprojecting soffit. They must always be usedwith RV Rafter Ventilators, to provide acontinuous ventilation path from the roofvoid to the outside without impairing theweatherproof function of the structure, asrequired by BS 5250. They can also be used in situations wheredetailing is difficult and tile or slateventilators are inappropriate, eg parapetwalls, secret gutters, corbelled eaves andmonopitch ridges. FV250 Ventilator canalso be used for flat roofs.

FV100 Over Fascia VentilatorInstalled continuously, providesguaranteed actual ventilationopening of 10 000mm2/m. Fit with gutter bracket spacers(supplied separately) wherenecessary.

FV250 Over Fascia VentilatorInstalled continuously, providesguaranteed actual ventilationopening of 25 000mm2/m. Fit with gutter bracket spacers supplied.

FV250

Specification clauses

EavesInstall Glidevale FV100/FV250 Fascia Ventilatorsto provide eavesventilation to the roofspace equivalent to _____ mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Ventilators to haveinternal pin arrangementfor resistance to drivingrain and large insects.Install continuously onthe two long edges ofthe roof/along the edgesof the roof as shown ondrawings. Fix in accordance withmanufacturer’sinstructions using gutterbracket spacers wherenecessary to ensure aclear air flow into theventilator.

Monopitch ridgeInstall Glidevale FV100Ventilators at monopitchridge to provideventilation to the roofspace equivalent to atleast 5000mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Fix in accordance withmanufacturer’sinstructions.

Flat roofInstall Glidevale FV250Ventilators to provideventilation to the roofspace equivalent to 25 000mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Install continuously onthe two long edges ofthe roof / along theedges of the roof / at allabutments to walls / asshown on drawings. Fix in accordance withmanufacturer’sinstructions.

FV FASCIA VENTILATORS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Advantages● Internal design provides effectiveresistance to both driving rain and largeinsects.

● Unobtrusive when fitted, hidden by gutterand roof covering.

● Can be used to provide ventilation aboveor below the underlay

● Patented gutter bracket spacers ensurecorrect airflow behind the gutter.

● Lightweight and durable.● Quick and easy to install, with no specialtools required.

● Compatible with all roof tile clips andeaves comb fillers.

● Modular lengths allow adjustment forfascia board inaccuracies.

● Position on the fascia minimises the riskof fire spread to the roof space.

● Integral dovetail joints ensure positiveand continuous interlock between units.

● Do not affect the slating/tiling process.

AuthorityCan be used to comply with roof spaceventilation requirements of BuildingRegulations Approved Document C2 and BS 5250.

Composition, ManufactureInjection moulded black polypropylene. Gutter bracket spacers neutral grey.

Gutter bracketspacersFitted behind gutterbrackets to ensure anunrestricted air flowbehind the gutter intothe ventilator, and toensure correct gutterpositioning

FV100

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 3: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Description, ApplicationsSV Soffit Ventilators are for installation ateaves with a projecting soffit, and mustalways be used with RV Rafter Ventilatorsto provide a continuous ventilation pathfrom the roof void to the outside withoutimpairing the weatherproof function of thestructure, as required by BS 5250. SV120 and SV200 Soffit Ventilators aredesigned for easy installation in existingsoffits, but can also be used in new work.

Advantages● Can be used with all common soffit board materials.

● Lightweight and durable.● Quick and easy to install; no special tools required.

● Prevent large insect ingress.● Independent of rafter spacing.● Suitable for new roofs and refurbishment.● Colours to match stained or painted soffit boards.

AuthorityCan be used to comply with roof spaceventilation requirements of BuildingRegulations Approved Document C2 and BS 5250.

Composition, ManufactureAll soffit strips are extruded PVC-U in2.44m lengths.SV120, SV200 and SV604E JointConnectors are injection-mouldedpolypropylene.

SV606Provides guaranteed actual ventilationopening of 10 000mm2/m. For sloping soffits; can also be used without a soffit board, butted up to brickwork. White or brown.

SV608Provides guaranteed actual ventilationopening of 25 000mm2/m. For thick section and narrow soffitboards and sloping soffit details.White or brown.

SV609Provides guaranteed actual ventilationopening of 25 000mm2/m. For soffit boards 6 - 10mm thick. White or brown.

SV604EProvides guaranteed actual ventilationopening of 10 000mm2/m. For soffit boards 6 - 10mm thick; will supporta 6mm soffit board up to 300mm widewithout additional noggings. Black, white or brown.

SV604E Expansion Joint ConnectorSupplied with SV604E to allow thermalmovement at straight joints, internal andexternal corners. Improves appearance byconcealing cut edges, maintains largeinsect protection, and simply clips intoposition. Black, white or brown.

SV200 Twist and LockProvides guaranteed actualventilation opening of 10 000mm2/m at 200mmcentres. Unique twistaction fixing. For soffitboards from 6mm thick. Hole size: 70mm diameter.Hole saw and fixing toolavailable. Black, white or brown.

SV SOFFIT VENTILATORS

Specification clauses

Soffit stripsInstall Glidevale SV604E/SV606/ SV608/ SV609soffit ventilators toprovide ventilation to theroof space equivalent to_____ mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Ventilators to beextruded PVC-U anddesigned to excludelarge insects. Colour: black/ white/brown. Installcontinuously on the twolong edges of the roof /along the edges of theroof as shown ondrawings. Fix in accordance withmanufacturer’sinstructions.SV604E only: fit JointConnectors at everystraight joint and everycorner.

SV120 and SV200Install GlidevaleSV120/SV200 soffitventilators at ___ mmcentres to provideventilation to the roofspace equivalent to _____mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Ventilators to bemoulded polypropyleneand designed to excludelarge insects. Colour: black/ white/brown. Install on the twolong edges of the roof /along the edges of theroof as shown ondrawings. Fix inaccordance withmanufacturer’sinstructions.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . .

SV120 Spring WingProvides guaranteed actual ventilationopening of 10 000mm2/m at 1.2m centres.Spring clip fixing. For soffit boards 5 - 20mm thick. Hole size: 270 x 92mm(template supplied). White or brown.

Page 4: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

RV200 RollLaid continuously over the raftersbefore the underlay is fixed, providesa maximum 25 000mm2 dependenton eaves ventilation inlet provision.Universal, adjusts for 400 - 600mmrafter centres.

RV625, RV625F (notshown, depth 40mm) Provides guaranteedactual ventilation openingof 25 000mm2/m at600/450/400mm raftercentres, and a minimumgap of 25mm inaccordance with BS 5250: 2011. Similarto RV601, RV601F.RV625F is for eaves withan open soffit; integral4mm insect screencomplies with BS 5250: 2011.Designed for standard600mm rafter centres, orcan be easily cut to suitcloser rafter spacings

RV635, RV655Universal rafter trays which adjust to the correct roofpitch and can be used in new-build, or inrefurbishment without disturbing the roof covering.Provides guaranteed actual ventilation opening of25 000mm2/m at 600mm rafter centres (RV655) or400mm rafter centres (RV635).RV635 can also be used at 450 - 600mm raftercentres; one per rafter provides not less than 10 000mm2/m.

Effective coverage per pack for rafter spacing:

600mm 6.0m or 10 rafter voids450mm 6.7m or 13 rafter voids400mm 6.0m or 15 rafter voids

RV601F, RV451F, RV401FProvides guaranteed actual ventilation opening of10 000mm2/m. For eaves with an open soffit,integral 4mm insect screen complies with BS 5250: 2011. Use for rafter centres:600mm RV601F450mm RV451F400mm RV401F

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .RV RAFTER VENTILATORS

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Specification clause

Install Glidevale RV____rafter ventilators toprovide a continuous airpath for roof spaceventilation between roofinsulation and roofunderlay at eavesequivalent to _____mm2/m inaccordance with BuildingRegulations ApprovedDocument C2 2004 amd2010 & 2013 and BS 5250: 2011. Ventilators to bevacuum-formed PVC[and to have integral4mm insect screen].Install continuously onthe two long edges ofthe roof / along theedges of the roof asshown on drawings. Fix in accordance withmanufacturer’sinstructions.

Design, ApplicationsRV Rafter Ventilators are designed toensure a clear air path between roofunderlay and insulation at all types ofeaves, in accordance with BuildingRegulations Approved Document C2. They should be installed continuously withFV Fascia Ventilators or SV Soffit Ventilators,to provide a continuous ventilation pathfrom the roof void to the outside without impairing the weatherproof function of the structure, as required by BS 5250.

Advantages● Do not affect the slating/tiling process.● Unique cross strengthening ribs on raftertrays prevent the underlay from saggingand blocking the airflow.

● Reduce the risk of cold bridging byenabling insulation to be laid right intoeaves.

● Lightweight and durable.● Quick and easy to install, with no special tools required.

● Suit standard rafter spacings.● Independent of SV and FV ventilators,enabling use with any depth of soffit.

AuthorityCan be used to comply with roof spaceventilation requirements of BuildingRegulations Approved Document C2 and BS 5250.

Composition, ManufactureVacuum-formed black PVC.

RV601, RV451, RV401Provides guaranteed actualventilation opening of 10 000mm2/m.Use for rafter centres:600mm RV601450mm RV451400mm RV401

Page 5: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Protect PVC-UEaves Skirt

Cold roof with soffit ventilationType HR or LR underlay

SV604E SoffitVentilator

RV601 Rafter Ventilator

Protect roofing underlay

SV120 Spring WingSoffit Ventilator

Protect A1 orWunderlayunderlay

Type HR underlay

Low-pitch roof with open soffitVentilation 25 000mm2/m

Protect A1 underlay

RV625F RafterVentilator withinsect screen

Protect PVC-UEaves Skirt

Protect A1 orWunderlay underlay

Warm roof with fascia ventilationType HR underlay, ventilation 25 000mm2/m

FV250 Fascia Ventilatorand Gutter BracketSpacer

Protect VC Foilvapour control layer

Counterbattens for50mm ventilation gapabove insulation andbelow underlay

TYPICAL DETAILS

Page 6: EAVES AND LOW LEVEL VENTILATION SYSTEMS...ventilator. Monopitch ridge Install Glidevale FV100 Ventilators at monopitch ridge to provide ventilation to the roof space equivalent to

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

GLIDEVALE LIMITED2 Brooklands Road, Sale, Cheshire M33 3SS Tel: 0161 905 5700 Fax: 0161 905 2085Email: [email protected] Web: www.glidevale.com

Glidevale Limited maintains a policy of continuous development and reserves the right to amend product specifications without notice.

A division of Building Product Design Ltd. Company Registration No; 3944123

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4602

Stockist’s stamp

Glidevale’s range of eaves ventilation are atthe core of an unrivalled capability.Glidevale also offer the widest range ofslate tile and ridge, abutment and valleyventilation solutions to compliment the eaveventilation range for both new build andrefurbishment projects. Glidevale is the ‘one stop shop’ for roofventilation solutions.

Other productsGlidevale underfloor and cavity wallventilators.

Glidevale loft access traps/ladder.

Glidevale Sunscoop tubular rooflights.

In-line Ridge Ventilators

G Range Tile and SlateVentilators