Upload
others
View
12
Download
0
Embed Size (px)
Citation preview
Electric Mortice Locks
AAA-
CAT-
069
060
9 M
S045
8
1
Strikes
3570 Series Electric Mortice Lock 2
3570/3670 Series Proximity Mortice Lock & Furniture 8
3570 Series Room Guard Electric Mortice Locks & Controller 12
3580 Series Electric Mortice Lock 14
EL402 Solenoid Lock 20
EL502 Solenoid Lock 22
EL580 Solenoid Lock 24
EL648 Motor lock 26
Power Transfer Cover 28
Contents
2 assaabloy.com.au
3570 Series Electric Mortice Lock
General Information Designed and manufactured in Australia, the 3570 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications.
The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic access control systems for use with higher security devices such as keypads or card readers.
Key FeaturesDesigned with flexibility in mind, the one lock can cover all functions and is easily configured on site for the required application.
Available in non monitored and monitored versions.
Monitoring features:• Dead latched and Locked
• Door position/Reed switch
• Dual key override monitoring
• Request to exit/REX
• LED indication
Field Changeable settings:• Fail safe/fail secure configuration.
• Multi-voltage - will work on 12-24 Vdc systems.
• Handing - left hand and right hand doors
• Selection of free lever or locked lever on both sides of the door
• Key override monitoring either side of the door
• Monitoring contacts – normally closed, normally open (for key override and request to exit only)
Standards and Compliance (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system)
(Durability) Australian Lock Standard (AS4145.2.1993)
Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)
C-Tick Certified
3570 Series: SCEC endorsed for intruder resistant areas
3579 Series: SCEC endorsed for secure areas
Hour4
S3
D3
3
3570 Series Electric Mortice Lock
Specification StatementThe lock should be capable of operation on voltages between 12 – 24Vdc and have a current consumption not more than 80mA (holding) @12Vdc and 50mA (holding) @24Vdc. Monitored locks must be capable of monitoring the following functions: Key override, door position / reed switch, selectable hub / Request to exit, & locking bar status. All monitoring outputs must have the ability to be wired independently. All settings – including: fail safe / fail secure, handing, hub selection must be field configurable.
3570 Technical Information
Voltage 12Vdc - 24Vdc Operating Voltage
Current 500mA (max) 80mA holding @ 12Vdc275mA (max) 50mA holding @ 24Vdc
LED Current When LED’s are fitted, add 15mA (max) to total current draw
Monitoring Dual Key override Deadlatched LockedDoor closedRequest to exit Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc
Environment Operational temperature range -20c to + 60c
Case/ Cover High purity Zinc alloy construction
Backset 60mm standard, 89 & 127 mm available
Latch bolts Reversible with Stainless Steel construction.
Door Clearance 3 – 6.5 mm
Door thickness Standard applications 32 to 50mm.
Cylinder Standard Lockwood oval shaped cylinders.
Cabling 1.6 metre length of cable with 12 pin socket supplied with each lock. Recommended cable: 18AWG (0.82mm²) cable runs up to 30m.
Furniture Compatible with Lockwood series door furniture.
Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and PolishedBrass(PB) finishes available
Dimension Backset
A 60 89 127
B 100 129 167
Note: width of case increases from 19mm to 23 mm for 3579 series SCEC lock
Note: For detailed electrical specifications, turn to page 7.
1915
15
18
175
25
37
64124
30
B
A
4
57
28.5
1.5
28.5
70
54
38
3246
39
1426
68
1.5
28.5
70
54
38
3246
39
1426
6824
18
1915
15
18
175
25
37
64124
30
B
A
4
57
28.5
Reed Magnet
4 assaabloy.com.au
3570 Series Electric Mortice Lock
Backset
60 mm 3
89 mm 4
127 mm 5
Fixing
Standard 5
Securafix® 6
Lock Functions
Primary lock 70
Vestibule lock 72
Combination lock 74
Secure Area Rated Lock 79
Electric Lock
Electric Lock EL
Safety Function
Fail Safe A (Power to lock)
Fail Secure E (Power to unlock)
Non-monitored lock (0 Cylinders) N0
Non-monitored lock (1 Cylinders) N1
Non-monitored lock (2 Cylinders) N2
Fully monitored lock including KOM (0 Cylinders)
Fully monitored lock including KOM (1 Cylinder)
Fully monitored lock including KOM (2 cylinders) KOM- (Key overrride moitoring)
Right Handing R
Left Handing L
Satin Chrome SC
Chrome Plate CP
Polished Brass PB
Backset
3
Fixing
5
Lock Functions
72
Electric Lock
EL
Safety Function
A
Sub Function
M2
Ordering ProcedureSample Part Number 3572ELAM2RSC is made up of several sections. Choose your product by selecting an option from each section. For example:
Sub Function
Handing
R
Right Handing
Finish
SC
Finish
Ordering Notes• 3570 Primary Locks can be set to achieve all
lock functions post purchase, and should be the preferred option when ordering.
• Customised locks are available upon request and incur an additional surcharge and 10 day lead time.
• Securafix locks are available in 60mm backset only and are made to order. 10 day lead time.
• See over page for Primary Lock part numbers.
Handing Chart
RIGHTHAND
LEFTHANDINSIDE
OUTSIDE
DOOR OPENING IN
RIGHTHAND
LEFTHAND
INSIDE
OUTSIDE
DOOR OPENING OUT
BacksetNominate backset as required, eg 60mm 3
FixingSelect the desired fixing method, eg Standard Fixing 35
35
Lock FunctionSelect function, eg Vestibule Lock
3572
Electrical VariantIndicate that this is an Electric Lock
3582EL
Safety FunctionSelect whether lock should be Fail Secure or Fail Safe, eg Fail Safe
3572ELA
Monitoring and Key Override OptionsSelect monitoring and cylinders to be supplied, eg Monitored Lock with two cylinders
3572ELAM2
HandingDetermine left or right handing, eg Right Handed
3572ELAM2R
FinishSpecify appropriate finish, eg Satin Chrome
3572ELAM2RSC
M0
M1
M2
5
3570 Series Electric Mortice Lock
Ordering Notes• Primary locks can be set post purchase to achieve all desired
lock settings e.g. fail safe or fail secure, left hand or right hand, combination lock (locked both sides) or vestibule lock (locked outside & free lever inside)
• All locks are Multi-voltage 12-24Vdc
• 3570 Primary locks (std 60mm backset) are stocked items. All other items are made to order, 10 day lead time.
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored No Cylinder 3570ELN0SC
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored 1 Cylinder 3570ELN1SC
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Non Monitored 2 Cylinder 3570ELN2SC
Electric Mortice Lock 4570 Primary Lock 89mm Backset Non Monitored No Cylinder 4570ELN0SC
Electric Mortice Lock 4570 Primary Lock 89 mm Backset Non Monitored 1 Cylinder 4570ELN1SC
Electric Mortice Lock 4570 Primary Lock 89 mm Backset Non Monitored 2 Cylinder 4570ELN2SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored No Cylinder 5570ELN0SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored 1 Cylinder 5570ELN1SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Non Monitored 2 Cylinder 5570ELN2SC
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored No Cylinder 3570ELM0SC
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored 1 Cylinder 3570ELM1SC
Electric Mortice Lock 3570 Primary Lock 60 mm Backset Monitored 2 Cylinder 3570ELM2SC
Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored No Cylinder 4570ELM0SC
Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored 1 Cylinder 4570ELM1SC
Electric Mortice Lock 4570 Primary Lock 89 mm Backset Monitored 2 Cylinder 4570ELM2SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored No Cylinder 5570ELM0SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored 1 Cylinder 5570ELM1SC
Electric Mortice Lock 5570 Primary Lock 127 mm Backset Monitored 2 Cylinder 5570ELM2SC
Primary Electric Mortice Lock Ordering Procedure
Part NoDescription - Non-Monitored
Description - Monitored (hub, deadlatch, solenoid, door position, key override monitoring all as standard)
Part No
Cylinders
Cylinders
6 assaabloy.com.au
3570 Series Electric Mortice Lock
A
29
1.5
14
12.7
184177
26.5
4
51
A
75
Extended Cylinders Extended cylinders should be considered when door thickness exceeds 50 mm or when the lock is mounted off centre in the door edge. A range of cylinders is available to suit various door thicknesses. Refer to ASSA ABLOY Australia Keying and Restricted Price List for further information.
1.5
28.5
70 54 38
46
A
Long Lipped Strike
Accessories - Rebate Kits
Bright Chrome 32 3570-2905BC 46 3570-3905BC
Polished Brass 32 3570-2905PB 46 3570-3905PB
Satin Stainless Steel 32 3570-2905SC 46 3570-3905SC
Part NumberFinish “A”
Accessories - Long Lipped Strikes
Bright Chrome 43.5 3570-5353CP 47.5 3570-5653CP
Polished Brass 43.5 3570-5353PB 47.5 3570-5653PB
Satin Stainless Steel 43.5 3570-5253SSS 47.5 3570-5453SSS
Part NumberFinish “A”
Extended Cylinders
Recommended Door Thickness
“A” Cylinder Projection
Cylinder Length
41 37 50 to 60
52 48 60 to 84
64 60 84 to 108
80 76 108 to 132
88 84 132 to 156
Accessories Ordering Information
LED assembly to suit 3570/3580 SP572-3129 (suits furniture for monitored locks)
7.5m extended 12 wire cable SP3570-1055
9/12 wire adaptor to suit 3570 series electric lock SP3570-5861
323mm Power Transfer Cable LC8810
543mm Power Transfer Cable LC8811
Part NumberProduct Description
7
3570 Series Electric Mortice Lock
12 Pin Connector
Key Override Monitor Selection
Switch Number
Hub MonitorLockSide
NormalFunction
B N / O
B N / C
A N / O
A N / C
1 2 3 4
OF F
ON
ON
OF F
ONOF F
ONOF F
SIDE B
N/O
N/C K.O.M
SWITCHSELECTION
Key OverrideMonitor Selection
Set the 2 way switchto desired setting
Key OverrideMonitor Selection
Hub Monitor Selecion
Deadlatched and locked centre tap (White)
Electrical Specifications
Circuit DiagramNote: Diagram depicts fail safe RH opened door, with handle and key in rest state.
DIL Switch Settings
Colour Function
Black Solenoid (0Vdc)
Red Solenoid Positive (12Vdc - 30Vdc)
Green LED (12Vdc - 30Vdc)
Yellow Door closed Reedswitch (NC)
Pink Door closed Reedswitch (common)
Light Blue Deadlatched and Locked (NC)
Grey Deadlatched and Locked (common)
White Deadlatched and Locked centre tap
Brown Hub monitor (NO or NC)
Blue Hub monitor (common)
Orange Key override monitor (NO or NC)
Violet Key override monitor (common)
Solenoid ActivationOperating Voltage: 12 - 24Vdc
Operating Current: 500mA (max) 80mA holding @ 12Vdc 275mA (max) 50mA holding @ 24Vdc
For confirmation of the above mentioned operating current, please see installation manual.
LED CurrentWhere LEDs are fitted, add 20mA (max) to total operating current.
Monitoring CircuitsMicroswitches: 500mA (max) @ 30Vdc each circuit Reedswitch: 100mA (max) @ 30Vdc
8 assaabloy.com.au
3570/3670 Series Proximity Mortice Lock & Furniture
General InformationWhen security, safety, functionality and stylish design are a priority, there’s only one solution – Lockwood Proximity Furniture!
Incorporating proximity technology within its sleek external door plate, the reader connects directly to a Lockwood electric mortice lock.
Easy to install and operate, Lockwood Proximity Furniture is available in a wide range of stylish levers and finishes to enhance any contemporary building design, bringing a new dimension to commercial security locking solutions.
One Install – One Connect. Comprising the Lockwood Electric Mortice Lock, HID Proximity Reader and Door Furniture.
Proximity Furniture™ is available in standard “through fix” and Securafix specifications.
Key Features• Integrated proximity reader -125 Khz HID Prox
• One install one connect
• Fully monitored
Monitoring features:• Dead latched and locked
• Door position/reed switch
• Dual key override
• Request to exit/REX
Field Changeable settings:• Fail safe/fail secure configuration.
• Multi-voltage - will work on 12-24 Vdc systems.
• Handing - left hand and right hand doors
• Selection of free lever or locked lever on both sides of the door
• LED indication
• Monitoring contacts – normally closed, normally open (for key override and request to exit only)
Standards and Compliance (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system)
(Durability) Australian Lock Standard (AS4145.2.1993)
Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)
C-Tick Certified
Hour4
S3
D3
9
3570/3670 Series Proximity Mortice Lock & Furniture
Specification Statement
The lock and door furniture should encompass an integrated proximity reader, capable of reading HID 125khz proximity technology with card formats up to 85bits. Operational voltage should be between 12-24Vdc. The lock must be capable of monitoring the following functions: Key override, door position / reed switch, independent hub / Request to exit, & locking bar status. All settings – including: fail safe / fail secure, handing, hub selection must be field configurable.
3570/3670 Technical Information
HID Reader HID 125KHz Proximity Reader Data Output: Weigand Supply voltage: 5-12Vdc LED: visual indication of reader / lock status
Lock Voltage 12Vdc - 24Vdc
Current 500mA (max) 80mA holding @12Vdc 275mA (max) 50mA holding @24Vdc
Indicator LED signalling door status
Monitoring Dual Key override Deadlatched LockedDoor closedRequest to exit Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc
Environment Operational temperature range -20°C to + 60°C
Case/ Cover Furniture: Solid Brass construction Lock: High purity zinc alloy construction
Backset Lock available in 60mm backset only
Latch bolts Reversible 15mm Stainless Steel construction.
Door Clearance 3 – 6.5mm
Door thickness Standard applications 32 to 45mm standard.
Cylinder Standard Lockwood oval shaped cylinders.
Cabling 1.6 metre length of cable with 12 pin socket Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m
Mortice Lock Compatible with Lockwood 3572PL and 3672PL electric mortice lock
Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available
Reed Magnet
1.5
28.5
70
54
38
3246
39
1426
68
1.5
28.5
70
54
38
3246
39
1426
68
24
18
1915
15
18
175
25
37
64124
30
B
A
4
57
28.5
1915
15
18
175
25
37
64124
30
B
A
4
57
28.5
1915
15
18
175
25
37
64124
30
B
A
4
57
28.5
1.5
28.5
70
54
38
3246
39
1426
68
Note: For detailed electrical specifications, turn to page 11.
10 assaabloy.com.au
Securafix®Ordering Notes:
• One internal plate and one external plate is required for each lock.
• For each set of furniture plates, one must be handed R and one handed L. Furniture plates are ordered separately to the Lock.
• The handing of Securafix plates cannot be changed.
Backset
3
Fixing
5
Lock Functions
70
Proximity Lock
PL
Monitoring
M0
Finish
SC
Ordering ProcedureSample Part Number 3570PLM0SC is made up of several sections. Choose your product by selecting an option from each section.
For example:
Backset
60 mm 3
Fixing
Standard 5
Securafix® 6
Lock Functions
Primary Lock 70
Proximity Lock
Proximity Lock PL
Monitoring
Monitored Lock including KOM (0 cylinders) M0
Monitored Lock including KOM (1 cylinders) M1
Finishes
Satin Chrome SC
Bright Chrome CP
Polished Brass PB
Plate Type
Exterior Square End 18
Exterior Round End 28
Plate Function
Exterior plate with HID 125 kHz Proximity Reader 78
Internal Plain plate & lever 05
Fixing
Standard (no suffix)
Securafix SF
Lever/Knob
Specify lever or knob. Subject to existing tier structure
Tier 1
00, 20, 32, 39, 40, 60, 70, 71, 78, 80, 83, 87, 90, 97.
Tier 2
41, 43, 44, 45, 48, 50, 53, 54, 57, 59, 61, 69, 72, 73, 74.
Handing
Right handed R
Left Handed L
Finishes
Chrome Plate CP
Polished Brass PB
Satin Chrome SC
Door Thickness
32-45mm (no suffix)
45-55mm 55
55-65mm 65
65-75mm 75
Plate Type
18
Plate Function
78
Fixing
SF
Lever/Knob
70
Handing
R
Finishes
CP
Proximity Furniture Ordering ProcedureSample Part Number 1878SF70RCP55 is made up of several sections. Choose your product by selecting an option from each section.
For example:
Door Thickness
55
3570/3670 Series Proximity Mortice Lock & Furniture
RIGHTHAND
LEFTHANDINSIDE
OUTSIDE
DOOR OPENING IN
RIGHTHAND
LEFTHAND
INSIDE
OUTSIDE
DOOR OPENING OUT
Ordering Notes• All 3570 & 3670 series proximity locks are non handed and can be set to required settings post purchase
Accessories Ordering Information
12 Wire cable extension 7.5m length 3570-1055
125 Khz HID reader assembly for prox furniture prox1-125khz
Part NumberProduct Description
11
Pin Colour Function
1 Black Common 0Vdc
2 Red Soleniod Positive
3 L. Blue Deadlatch Monitor N/C
4 Blue Door Monitor Reed N/C
5 Grey Hub Monitor N/O or N/C
6 Violet Key Override Monitor N/O or N/C
7 Brown Monitor Common
8 Pink Reader Power 5-12Vdc
9 Orange Green LED
10 Yellow Reader 0Vdc
11 Green Weigand Data 0
12 White Weigand Data 1
Plug Housing
To Power Supply
From Electric Lock
Receptacle Housing
3570/3670 Series Proximity Mortice Lock & Furniture
12 assaabloy.com.au
3570 Series Room Guard Electric Mortice Locks & Controller
INSIDE ROOM
TurnKnobPower
TransferDevice
Emergencyoverride switches(outside room)
12Vdc power supply
3570 EL ElectricMortice Lock
Room GuardPrivacy Controller
LED
PowerTransferDevice
regulated
The Room Guard Privacy controller system provides electronic lock control of multiple doors for any room requiring privacy by the occupants. The most common applications are shared ensuites in hospitals and conference rooms with two or more entry doors.
The system allows all doors to be locked and unlocked from any door in the system. Each lock provides a clear visual indication, both inside and outside, which displays the locked/unlocked status of the door at a glance.
Features• Uses standard 3570EL series mortice lock
• Non handed – all settings are field configurable
• One touch privacy
• Clear visual indication - LED furniture
• Unique integrated turn knobs
• Emergency override
Applications• Shared ensuites/toilets
• Darkroom studios
• Conference rooms
• Laboratories
• Any area for which “one touch” privacy locking is required
Function In the dormant state, all locks are unlocked and the LED on the external furniture plate indicates green.To lock the lock1. Close all doors
2. Activate one of the turn knobs located on the inside of the door
3. Simultaneously the lever handles on the outside of each door will lock and the LED furniture indication will change to red. (inside lever will remain free at all times)
To Unlock the Room1. Operate the inside lever of either lock.
2. Simultaneously the locks will unlock and the LED furniture indication will return to green.
Standards and Compliance (Security) Australian Lock Standard (AS4145.2.1993) (when used with equivalent security level keying system)
(Durability) Australian Lock Standard (AS4145.2.1993)
Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)
C-Tick Certified
Hour4
S3
D3
13
3570 Series Room Guard Technical Information
Voltage 12Vdc - 24Vdc
Current 500mA (max) 80mA holding @ 12Vdc 275mA (max) 50mA holding @ 24Vdc
LED Current When LED’s are fitted, add 15mA (max) to total current draw
Monitoring Microswitches: 500mA (max) @ 30Vdc each circuit. Reedswitch: 100mA (max) @ 30Vdc
Environment Operational temperature range -20c to + 60c
Case/Cover High purity Zinc alloy construction
Backset 60mm standard, 89 & 127 mm available
Latch bolts Reversible with Stainless Steel construction
Door Clearance 3 – 6.5 mm
Door thickness Standard applications 32 to 50mm
Cylinder Standard Lockwood oval shaped cylinders
Cabling 1.6 metre length of cable with 12 pin socket supplied with each lock Recommended cable: 18AWG (0.82mm²)
Furniture Compatible with Lockwood series door furniture
Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available
Note: For detailed electrical specifications, turn to page 7.
Specification StatementLocking control of the room must be via a standalone door controller independent of the building electronic access control system. The controller shall be capable of providing simultaneous locking/unlocking of up to 4 locks via internal integrated turn knobs. Emergency egress or unlocking to be achieved via single downward action of internal lever or externally mounted override switch. The locks should be capable of operation on voltages between 12 – 24Vdc. All lock settings – including: fail safe/fail secure, handing, hub selection must be field configurable.
Note: Due to the variety of installation décor, Lockwood does not supply emergency release push buttons. However we recommend a Clipsal model 31 architrave mounting plate with model 30MBP push button, or equivalent, available from most electrical wholesalers.
Room Guard Privacy Controller plus regulated power supply (12Vdc, 1.5AMP).
RG2PS
Room Guard Privacy Controller. RG2
Turn knobs, designed for the integrated assembly with Lockwood electric mortice locks. Other finishes available upon application.
RG3SC
1 x Room Guard Privacy Controller
RG2PS or RG2
2 x Room Guard Privacy Controller turn knobs RG3SC
2 x Electric Mortice Locks 3570ELM0SC
2 x Power transfer devices LC8810
2 x Exterior door furniture 1822/70SC
2 x Interior door furniture 1920/70SC
2 x 7.5M extended cables SP3570-1055
Ordering Information
Product Description Part Number
3570 Series Room Guard Electric Mortice Lock & Controller
Pink
Pink
3570 EL Electric 3570 EL Electric
Room Guard Privacy Controller
Standard Two Door Connection
A typical room with two doors requires the following equipment:
Accessories Ordering Information
7.5m extended 12 wire cable SP3570-1055
9/12 Wire adapter to suit 3570 series electric lock SP3570-5861
Part NumberProduct Description
14 assaabloy.com.au
3580 Series Electric Mortice Lock
Designed and manufactured in Australia, the 3580 series electric mortice is a high performance lock of superior quality. It is constructed from high grade zinc alloy, with a stainless steel latch bolt and face plate and is suited for all commercial applications.
The lock can be operated by push buttons, intercom systems and key switches; or integrated with electronic access control systems for use with higher security devices such as keypads or card readers.
The 3580 series is available in a wide variety of configurations to suit varying requirements and is especially suited to narrow style or short backset applications.
Key FeaturesAvailable in non monitored and monitored versions.
Monitoring features:• Dead latched
• Door position/reed switch
• Key override
• Request to exit/REX
Available configurations:• Fail safe or fail secure
• 12Vdc or 24Vdc
• Field changeable monitoring contacts – normally closed, normally open
• Field changeable handing - Left hand and right hand doors
• Selection of free lever or locked lever on both sides of the door
• Key override monitoring
• LED indication
Standards and Compliance (Security) Australian Lock Standard (AS4145.2.1993)
(Durability) Australian Lock Standard (AS4145.2.1993)
C-Tick Certified
S2
D3
15
3580 Series Electric Mortice Lock
3580 Series Technical Information
Voltage Available in 12Vdc or 24Vdc
Current 12Vdc ± 5% 250mA (max) 24Vdc ± 5% 125mA (max)
LED Current When LED’s are fitted, add 15mA (max) to total current draw
Monitoring Key override Deadlatched and door closed Request to exit Hub/Deadlatch/Key override monitor: max ratings 500mA@30Vdc Door Status Monitor: max ratings 3W, 250mA (max) @ 12Vdc, 125mA (max) @24Vdc
Environment Operational temperature range -20°c to + 60°c
Case/ Cover High purity zinc alloy construction
Backset 23mm standard. 25.4, 30 & 38 mm extended available
Latch bolts 15mm Stainless Steel construction
Door Clearance 3 – 6.5 mm
Door thickness Standard applications 32 to 50mm Extension kits available
Cylinder Standard Lockwood oval shaped cylinders
Cabling 3.6 metre length of cable with 9 pin socket supplied with each lock. Recommended cabling: 18AWG (0.82mm²) cable runs up to 30m
Furniture Compatible with Lockwood series door furniture
Standard Finishes Satin Chrome(SC) standard. Bright Chrome (CP) and Polished Brass(PB) finishes available
Specification StatementThe lock should be capable of operation on voltages of 12 or 24Vdc and have a current consumption not more than 250mA (max) @12Vdc and 125mA (max) @24Vdc. Monitored locks must be capable of monitoring the following functions: Key override, door position/reed switch & independent hub/ Request to exit. All monitoring outputs must have the ability to be wired independently. The lock must be capable of operating fail safe or fail secure, left or right hand, and have field configurable hub selection.
1.5
28.5
70 54 38
32
46
39
1.5
15
1.524
8654
27 25
100
260
15
15
18
X
Y 25
155.5212.5
20
79
2890
336.5
32
1.5
28.5
70 54 38
32
46
39
1.5
15
1.524
8654
27 25
100
260
15
15
18
X
Y
1.5
28.5
70 54 38
32
46
39
1.5
15
1.524
8654
27 25
100
260
15
15
18
X
Y
24
18
Limiting Dimensions
Dimension Backset
X 23 25.4 30 38
Y 36.4 39 43.6 51.7
Accessories Ordering Information
Anti-Clockwise Rebate Kit Replace ## with finish code (SC, CP, PB) 3580-2902AC##
Clockwise Rebate Kit Replace ## with finish code (SC, CP, PB) 35802902CW##
LED Assembly to suit 3570/3580 SP572-3129
7.5m extended 9 wire cable SP3580-1052
Part NumberProduct Description
Reed Magnet
Note: For detailed electrical specifications, turn to page 18.
16 assaabloy.com.au
3580 Series Electric Mortice Lock
Backset
23 mm 3
25.4 mm 4
30 mm 5
38 mm 6
Door Material
Metal 58
Timber 59
Lock Function
Vestibule lock 2
Combination Lock 4
New Product
EL
Safety Function
Fail Safe A (Power to lock)
Fail Secure E (Power to unlock)
Sub Function
Non-monitored lock (0 Cylinders) N0
Non-monitored lock (1 Cylinder) N1
Non-monitored lock (2 Cylinders) N2
Monitored Lock (0 Cylinders) M0
Monitored Lock (1 Cylinder) M1
Monitored Lock (2 Cylinders) M2
Monitored Lock including KOM (0 Cylinder) M4
Monitored Lock including KOM (1 Cylinder) M5
KOM- (Key overrride moitoring)
Handing
Right Handing R
Left Handing L
Finish
Bright Chrome CP
Polished Brass PB
Satin Chrome SC
Options
24 volt model 62
Backset
3
Door Material
58
Lock Function
2
New Product
EL
Safety Function
A
Sub Function
M2
Ordering ProcedureSample Part Number 3582ELAM2RSC62 is made up of several sections. Choose your product by selecting an option from each section.
For example:
Handing
R
Finish
SC
Options
62
BacksetNominate backset as required, eg 23mm 3
Door MaterialNominate door material, eg Metal
358
Lock FunctionSelect function, eg Vestibule Lock
3582
Electrical VariantIndicate that this is an Electric Lock
3582EL
Safety FunctionSelect whether lock should be Fail Secure or Fail Safe, eg Fail Safe
3582ELA
Monitoring and Key Override OptionsSelect monitoring and cylinders to be supplied,eg Monitored Lock with 2 cylinders
3582ELAM2
HandingDetermine left or right handing, eg Right Handed
3582ELAM2R
FinishSpecify appropriate finish, eg Satin Chrome
3582ELAM2RSC
OptionsSpecify 24Vdc opion when required
3582ELAM2RSC62
17
3580 Series Electric Mortice Lock
Accessories Rebate kits to suit 13 mm rebated timber doors with a minimum backset of 30 mm includes an adaptor to mount the lock and a special strike plate. Handing of the rebate kits is determined by the opening movement of the door on which the lock is fitted.
A A
29
1.5
14
12.7
184177
26.5
4
51
A
75
“A” Cylinder Projection Cylinder Length Recommended Door Thickness
41 37 50 to 60
52 48 60 to 84
64 60 84 to 108
80 76 108 to 132
88 84 132 to 156
Extended Cylinders Extended cylinders should be considered when door thickness exceeds 50 mm or when the lock is mounted off centre in the door edge. A range of cylinders is available to suit various door thicknesses. Refer to ASSA ABLOY Australia Keying and Restricted Price List for further information.
Finish Anti-clockwise Clockwise
Satin Chrome 3580-2902ACWSC 3580-2902CWSC
Bright Chrome 3580-2902ACWCP 3580-2902CWCP
Polished Brass 3580-2902ACWPB 3580-2902CWPB
18 assaabloy.com.au
3580 Series Electric Mortice Lock
2
3
4
5
6
7
8
9
Solenoid12V dc
CommonDeadlatch anddoor closed status
Deadlatch anddoor closed status
LED
Hub monitor common
Hub monitor( LH/RH, NO/NC )
Key overridemonitor ( NO/NC )
Key overridemonitor common
EXTERNALLED
DILSWITCH
DILSWITCH
Red
Green
SolenoidProtectionDiode
Resistor
Reedswitch
CNO
NC
NO
NC
NO
NC
(1)
(2)
(4)
(3)
RHS
LHS
(1)
(2)
NO
NC
C
C
C
9 Pin Connector
Common1
Key Override Monitor Selection
Set the 2 Wsetting, refer to table.
AY DIL SWITCH to desired
N / O
N / C
1 2
OFF
ON
ON
OFF
Hub MonitorSwitch No.
Switch No.
LockSide
B N / O
B N / C
A N / O
A N / C
1 2 3 4
OFF
ON
ON
OFF
ONOFF
ONOFF
NormalFunction
NormalFunction
Circuit Diagram
Note: Diagram depicts fail safe 12V RH opened door, with handle and key in rest state.
Pin Colour Function1 Black Common (0Vdc)
2 Red Solenoid (12Vdc or 24Vdc)
3 Grey Deadlatch and door closed status (common)
4 Yellow Deadlatch and door closed status
5 Green LED
6 Brown Hub monitor (common)
7 Blue Hub monitor (RH/LH, NO/NC)
8 Orange Key override monitor (NO/NC)
9 Violet Key override monitor (common)
To power supplyPlug Housing
ReceptacleHousingFrom electrical lock
Electrical Specifications
19
Electric Mortice Locks
20 assaabloy.com.au
ABLOY EL402 Solenoid Lock
General DescriptionABLOY EL402 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that’s never been available before. Because of its symmetrical trigger bolt, ABLOY EL402 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes.
Key Features• Field selectable Fail Safe/Fail Secure
configuration
• Non Handed Symmetrical trigger bolt
• Visual Lock Status indicator
• Immediate release of Deadlocking
• Push or Pull operation
• Wide Operating Voltage
• Adjustable Backset Between 25 – 35 to suit most narrow style applications.
Applications • Offices
• Storage rooms
• Consulting rooms (All Narrow style)
• Top of glass doors 180°Note: The EL402 is not recommended
• For use in doors with seal force
• For use in fire doors
Note: EL 412 & EL 413 are replaced with EL 402
21
ABLOY EL402 Solenoid Lock
Specification StatementThe mortice lock must consist of High grade pure zinc alloy, the lock needs to have an adjustable backset 25,28,30,33 and 35mm. The latch bold must be no less than 14.5mm with complete double action trigger. The voltage must be variable between 12-24Vdc with tolerance of 10% up or down. The lock and unlocked status must be fully monitored by means of dry contacts.
EL402 Solenoid Lock Technical Information
Voltage 12-24 Vdc -10%/ +15% STAB
Current 550mA (max) 240mA holding @12Vdc 270mA (max) 110mA holding @24Vdc
Monitoring Microswitch 0.4A 30V AC (deadlock status)
Environment Operational temperature range -20°C to +60°C
Case/Cover High Purity zinc alloy
Forend 25mm
Backset 25, 28, 30, 33, 35mm (adjustable)
Latchbolts Double action latch 14.5mm
Door Clearance 3-5 mm
Cylinder ABLOY classic or ABLOY Disklock Pro
Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m
Furniture ABLOY Architectural Hardware
Standard Finishes Chrome plated forend, lock case yellow chrome plated
225
12
200
15
1923
.524
153.
5
40 / 43 / 45 / 48 / 50
25 / 28 / 30 / 33 / 35
40
8
5.5x2
325
13
424 14.5
87
47.5
129.
5
1.5
41.5
+12 - 24 Vdc
redblackyellowbluegreenCommon
LockedOpen
blackyellowblue
-
Ordering Information
ABLOY EL 402 Narrow Style Electric Mortice Solenoid Lock EL402
Cable 6m for EL402 EA211
AccessoriesFurniture (Narrow Style) 4/0645
Part NumberProduct Description
22 assaabloy.com.au
ABLOY EL502 Solenoid Lock
General DescriptionABLOY EL502 is typically used in the interior doors of business premises and educational buildings. The locks include a special double action bolt for quick and easy use and offer a cost-effective way of electric locking without compromising performance. The locks can be controlled by a variety of electrical impulse generating equipment such as card readers, keypads and timers. The locks can be connected to automatic swing door operators and are an excellent solution for access control systems. The new revolutionary adjustable backset feature offers unique flexibility that’s never been available before. Because of its symmetrical trigger bolt, ABLOY EL502 can be used in double swing doors. The lock can always be opened mechanically by key or by thumb turn and the bolt deadlocks automatically when the door closes.
Key Features• Field selectable Fail Safe/ Fail Secure
configuration
• Non Handed Symmetrical trigger bolt
• Visual Lock Status indicator
• Immediate release of Deadlocking
• Push or Pull operation
• Wide Operating Voltage
• Backset 50mm
Applications• Offices
• Storage rooms
• Consulting rooms
Note: The EL402 is not recommended;
• For use in doors with seal force
• For use in fire doors
Note: EL 512 & EL 513 are replaced with EL502
23
ABLOY EL502 Solenoid Lock
EL502 Solenoid Lock Technical Information
Voltage 12-24 Vdc -10%/ +15% STAB
Current 12V Max 550 mA, Normal 240mA 24V Max 270mA, Normal 110mA
Monitoring Microswitch 0.4A 30V AC (Deadlock status)
Environment Operational temperature range -20°C to +60°C
Case/ Cover High Purity zinc alloy
Forend 22mm
Backset 50mm
Latchbolts Double action latch 14.5mm
Door Clearance 3-5 mm
Cylinder ABLOY classic or ABLOY Disklock Pro Scandanavian oval type
Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m
Furniture ABLOY Architectural Hardware
Standard Finishes Chrome plated forend, lock case yellow chrome plated
Specification StatementThis mortice lock must consist of High grade pure zinc alloy, the lock needs to have a backset 50mm. The latch bold must be no less than 14.5mm with complete double action trigger. The voltage must be variable between 12-24Vdc with tolerance of 15% up or 10% down. The lock and unlocked status must be fully monitored by means of dry contacts.
1229
30
225
203
30
14710
5
25.5
19
6.5
10.5
158
6.5
5.5
102
13
50
3
22
424 14.5
75
37.5
+12 - 24 Vdc
redblackyellowbluegreenCommon
LockedOpen
blackyellowblue
-
Ordering Information
ABLOY EL 502 Electric mortice Solenoid Lock EL502
Cable 6m for EL502 EA211
Part NumberProduct Description
24 assaabloy.com.au
ABLOY EL580 Solenoid Lock
General InformationABLOY EL580 Locks are suitable for interior or exterior doors of business premises and the exterior doors of apartment buildings and detached houses.
Abloy EL580 is suitable for use in exit doors as the inside handle is free for egress at all times. The locks are automatically deadlocked from the Exterior when the door is closed. The locks can be controlled by a variety of electrical impulse generating equipment, such as a card reader, keypad and timer.
Key Features• Interchangeable handing
• Changeable function of handle control
• Configurable fail safe or fail secure
• 12-24Vdc operating voltage
• Configuration of deadbolt either 14mm or 20mm
• Increased protection against manipulation
• Low current feature while continuous control
Applications• Offices
• Storage rooms
• Consulting rooms
• Fire Doors
Voltage 12-24Vdc -10%/ +15% STA
Current 12V Max 550 mA, Normal 270mA 24V Max 240mA, Normal 110mA
Environment Operational temperature range -20°C to +60°C
Case/ Cover High purity Zinc alloy construction
Backset 50mm
Latchbolts Bolt throw: 14mm or 20mm configurable
Cylinder Scandinavian Oval or Finnish type cylinder
Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m
Furniture ABLOY Architectural Hardware
Standard Finishes Chrome plated forend
EL580 Solenoid Lock Technical Information Specifier StatementThe mortice lock must consist of High grade pure Zinc alloy The lock needs to have a backset of 50mm. The latch bolt must be configurable between 14 - 20mm. It also needs to be field selectable for the fail safe and fail secure configuration. The voltage must be variable between 12-24Vdc. The following parts need to be fully monitored; bolt position, handle down and REX by means of dry contacts.
Ordering Information
ABLOY EL580 Electric Mortise Solenoid Lock EL580
Cable 6m for EL580 EA210
Part NumberProduct Description
25
Electric Mortice Locks
26 assaabloy.com.au
ABLOY EL648 Motor Lock
General InformationThe EL648 is a heavy duty motor lock with hook bolt for narrow style doors. They provide superior mechanical strength against physical attack. The EL648 is used in high security auxiliary lock in applications such as gates and exterior doors of industrial premises, shopping centres, business premises etc. The lock is especially suited for sliding doors as it can be installed in the door frame or the door leaf. EL648 is ideal for night locking that requires greater strength and security. The lock can be controlled by a variety of electrical impulse generating equipment such as a card reader, keypad or timer. This lock is suitable for use with sliding door operators.
Key Features• High security motor bolt.
• Lock case is connected with a separate control unit.
• 12-24Vdc operating voltage
• Configuration of deadbolt either 14mm or 20mm
• Increased protection against manipulation
• Striker plate includes door position magnet.
• Fully monitorered, bolt in/bolt out, door position manual operation
• Can configure lock in fail safe and fail secure (Backup card required to set the lock case to go to desired position in case of power failure)
Note: Lock requires EA460 Control unit to operate.
27
Specification StatementThe mortice lock must consist of high grade pure zinc alloy. The bolt must be controlled by means of motor and the shape of the bolt must be in hook shape for added security. A separate controller needs to be connected to the lock to enable trigger and monitoring functions. The voltage must be variable between 12-24Vdc with tolerance of 15% up or down. The following parts need to be fully monitored; bolt position, door position by means of dry contacts. The lock must be suitable for internal and external use.
EL648 Motor Lock Technical Information
Voltage 24Vdc ± 15% stabilised
Current Idle 70mA, Normal 150mA and Max 750mA
Monitoring Door position, Bolt Position Mechanical trigger
Environment Operational temperature range -25°C to +70°C
Case/ Cover High purity Zinc alloy construction
Backset 25mm or 35mm
Latchbolts Bolt throw: 22mm Hook bolt
Cylinder Scandinavian oval type, Finnish type
Cabling Recommended cable: 18AWG (0.82mm2) cable runs up to 30m
Furniture ABLOY Architectural Hardware
Standard Finishes Chrome plated steel forend, yellow chrome, lacquered lock body.
��
��
����
����
��
����
������
�������
���
���
���
�����
����
����
����
��
���
���
��
��
TECHNICAL DETAILSOperating voltage 12 - 24 V DC (+15%) stab. 12 V AC (-10%/+50%) RMSCurrent Normal 150 mA Idle 70 mA Max. 750 mAAdjustable delay 2..15 secTemperature range -20oC...+60oCHook bolt 22 mmBackset 25, 35 mmForend 25 mm
FINISHChrome plated forend
CYLINDERS- Scandinavian oval type; ABLOY® PROTEC, ASSA, RUKO, TrioVing or other.- Finnish type; ABLOY® CLASSIC or ABLOY®
PROTEC
PACKAGELock case, control unit, striker plate EA300 with door contact, connection plugs, �xing screws and lock case manual.
DIMENSIONS
APPLICATION
FUNCTIONBolt is withdrawn and thrown by motor. Lock case is connected with a separate control unit included in the lock package. Striker plate EA300 with integral door contact must be used with the lock. After an opening impulse hook bolt is withdrawn. After door use or delay, the hook bolt is released immediately.
ABLOY® EL648 can be con�gured to fail locked or fail unlocked mode in case of power failure (requires a backup card connected to the EA460 control unit).
ABLOY® EL654 enables data communication between lock case and control unit EA470. When installed together with EL480 / EL482 / EL402 / EL490, the lock offers the following options for operation: - both locks are deadlocked - EL480 / EL482 / EL402 / EL490 is deadlocked, EL654 is open - both locks are open
WIRING PRINCIPLE
Abloy OyWahlforssinkatu 20P.O. Box 108FI-80101 JOENSUUFINLANDTel. +358 20 599 2501Fax +358 20 599 2209
www.abloy.com
Abloy Oy is one of the leading manufactures of locks, locking systems and architectural hardware and the word´s leading developer of products in the �eld of electromechanical locking technology.
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
ABLOY® EL648 and EL654 are used as high security auxiliary locks e.g. in gates and exterior doors of industrial premises, shopping centres and business premises etc. The locks are especially suited for use in sliding doors as they can be installed in door frame or door leaf.
ABLOY® EL654 can be installed together with e.g. EL402, when both locks can be controlled individually. EL402 has a double action bolt for quick and easy locking and is well suited for doors that are frequently used in daytime. EL654 is ideal for night time locking that requires greater strength and security.
Both ABLOY® EL648 and EL654 can be controlled by a variety of electrical impulse generating equipment, e.g. card reader, keypad or timer. The locks are suitable for use with door automatics. Available also: EL655 compatible with Finnish type cylinder.
ABLOY® EL654 and control unit EA470 are ASSA ABLOY Hi-O Technology TM certi�ed products.
This document may not be used in the installation of a lock. Drilling and wiring diagrams ans installation instructions are included in the lock case manual, which is included in each lock case package.We reserve the right to make alterations to the products described in this lea�et.
CYLINDERS AND ACCESSORIES (Please order separately)
CYLINDERS ACCESSORIES
ABLOY®
PROTEC
CABLES
SHORT CONNECTION CABLE (EL654)
LEAD COVERS
BACKUP CARD (EL648)
Single with thumbturn
Double
CY201N / 6415
CY202N / 6412CY044NCY065N
EL648: EA214 (6m)EA224 (10m)EL654:EA216 (6m)EA226 (10m)
EA235 (EL490)EA236 (EL402, EL480, EL482)
EA280EA281
952169
EL648
EL654
8801
231
12/
2008
1.0
00 k
pl S
uom
en P
aino
tuot
e, J
oens
uu
Abloy OyWahlforssinkatu 20P.O. Box 108FI-80101 JOENSUUFINLANDTel. +358 20 599 2501Fax +358 20 599 2209
Abloy OyWahlforssinkatu 20P.O.Box 108FI-80101 JOENSUUFINLANDTel. +358 20 599 2501Fax +358 20 599 2209
Ordering Information
ABLOY EL 648 Electric mortice Solenoid Lock EL648
Cable 6m for EL648 EA214
Strike plate with integrated magnet EA300
Accessories Control Unit EA460
Part NumberProduct Description
ABLOY EL648 Motor Lock
28 assaabloy.com.au
Power Transfer Lead
Lockwood Power Transfer CoverLC8810The LC8810 and LC8811 Power Transfer Lead Covers are designed to ensure unbroken transfer of wires between door and frame in electric locking situations.
Features:• Provides unbroken connection from controller
to lock, for cable up to 8 mm diameter.
• Vandal-resistant chrome plated steel flexable.
• Completely concealed when the door is closed.
ApplicationsLC8810
The LC8810 is a shorter unit suitable for hinged doors which open to 90° (maximum of 120°).
LC8811The LC8811 is designed for use on doors which open more than 120°, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors.
Standards and Compliance
Successfully fire rated up to 4hrs on fire door assemblies in accordance with AS1905.1. 2005 (Part 1: Fire resistant door sets)
Hour4
29
Power Transfer Lead
LC8810The LC8810 is a shorter unit suitable for hinged doors which open to 90° (maximum of 120°).
LC8811The LC8811 is designed for use on doors which open more than 120°, or have a gap from pin hinge to door frame of more than 20 mm. NB. Not suitable for centrally pivoted doors.
90°
120°
Door Frame
O12
23.8
17
323
17
O12
299
25
8
250
29
O10
543
519
478
O12
17
O12 46
0
20
29
O10 20
O12
23.8
17
323
17
O12
299
25
8
250
29
O10
54
3
51
9
47
8
O12
17
O12
460
20
29
O10
20
Door Frame
120°
Ordering Information
323mm Power Transfer Cable LC8810
543mm Power Transfer Cable LC8811
Part NumberProduct Description
ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.
ASSA ABLOY is represented in all major regions, in both mature and emerging markets, with leading positions in Australia, Europe and North America.
As the world’s leading lock group, ASSA ABLOY offers a more complete product range of door opening solutions than any other company on the market.
ASSA ABLOY Australia Pty Limited ABN 90 086 451 907 ©2009
Head OfficeASSA ABLOY Australia Pty Limited 235 Huntingdale Road, Oakleigh Victoria, 3166 Australia
1300 LOCK UP (1300 562 587) [email protected]
tbc copy
The global leader in door opening solutions
AAA-
CAT-
069
060
9 M
S045
8