Elettrostart Rev0 ENG

Embed Size (px)

DESCRIPTION

Elettrostart Solenoids technical data

Citation preview

  • C.E.I. srl

    CON INTERRUTTORE INTERNO WITH INTERNAL SWITCHPER INTERRUTTORE ESTERNO FOR EXTERNAL SWITCH

    TRAZIONE PULLSPINTA PUSH

    TRAZIONE PULLSPINTA PUSH

    TRAZIONE PULLSPINTA PUSH

    MODELLI MODELSSPECIAL

    CON INTERRUTTORE INTERNOWITH INTERNAL SWITCH

    TRAZIONEPULL

    PER INTERRUTTORE ESTERNOFOR EXTERNAL SWITCH

    TRAZIONE PULLSPINTA PUSH

    60GRUPPOFAMILY 46GRUPPOFAMILY

    50GRUPPOFAMILY

    40GRUPPOFAMILY

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    STAFFA BRACKET A

    STAFFA BRACKET B

    STAFFA BRACKET A

    STAFFA BRACKET B

    STAFFA BRACKET A

    STAFFA BRACKET B

    STAFFA BRACKET C

    INTERMITTENTE (D)INTERMITTENT (D)

    TRAZIONE PULLSPINTA PUSH

    STAFFA BRACKET A

    STAFFA BRACKET A

    STAFFA BRACKET C

    STAFFA BRACKET A

  • C.E.I. srlC.E.I. srl

    SPECIFICHE ELETTROMAGNETICHE ELECTROMAGNETIC SPECIFICATIONS

    CODICE DIAMETRO CORSA FORZA ALLA BOBINA DI POTENZA BOBINA DI TENUTA PESO GRUPPO DIAMETER STROKE PARTENZA PULL COIL HOLD COIL WEIGHT FAMILY FORCE CODE MAX AT START 12 V.C.C. 24 V.C.C 12 V.C.C. 24 V.C.C

    60 60 mm 50 mm kg 8.4 47 A 24.5 A 0.65 A 0.30 A kg 1.950 46 46 mm 26 mm kg 7 40 A 23.5 A 0.60 A 0.30 A kg 0.810

    50 50 mm 40 mm kg 4.3 41 A 23 A 0.50 A 0.28 A kg 1.180

    40 40 mm 40 mm kg 1.7 31 A 15.2 A 0.53 A 0.29 A kg 0.760

    MODELLO E - CON DOPPIA BOBINA PER SERVIZIO CONTINUATIVOMODEL E - DUAL COIL SOLENOID FOR CONTINUOUS DUTY

    CODICE DIAMETRO CORSA FORZA ALLA ASSORBIMENTO BOBINA PESO GRUPPO DIAMETER STROKE PARTENZA COIL INPUT WEIGHT FAMILY FORCE CODE MAX AT START 12 V.C.C. 24 V.C.C

    60 60 mm 50 mm kg 8.4 37 A 20 A kg 1.830 46 46 mm 26 mm kg 7 27 A 13 A kg 0.740

    50 50 mm 40 mm kg 4.3 27 A 14.5 A kg 1.170

    40 40 mm 40 mm kg 1.7 25 A 11 A kg 0.740

    MODELLO D - CON UNA SOLA BOBINA PER SERVIZIO INTERMITTENTEMODEL D - SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    DIAGRAMMA DELLE FORZE E CORSE DIAGRAM OF FORCES AND STROKES

    010 20 30 40 50

    5

    10

    15

    20

    CORSA (mm) STROKE (mm) 1 kg = 9.81 Newtons

    FORZA (kg) FORCE (kg)GRUPPOFAMILY

    CORSA MASSIMA 50mmMAXIMUM STROKE 50mm60 kg 8.4 (N82)

    GRUPPOFAMILY

    CORSA MASSIMA 26mmMAXIMUM STROKE 26mm46 kg 7.0 (N68)

    GRUPPOFAMILY

    CORSA MASSIMA 40mmMAXIMUM STROKE 40mm50 kg 4.3 (N42)

    GRUPPOFAMILY

    CORSA MASSIMA 40mmMAXIMUM STROKE 40mm40 kg 1.7 (N16)

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • FAMILY E - ES 40

    A C

    B VERSIONES

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 31 A 15.2 A Hold current 0.53 A 0.29 A Duty service Continuous (100%) Stroke 40 mm Force at starting 1.7 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 0.76 Kg

    SPECIFICATIONS

    OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    BRACKET A BRACKET B BRACKET C

    40

    40

    104

    104

    3222.5

    7333

    7333

    M6x20

    M6x20

    7

    7

    25

    36

    52

    52

    65

    3

    3

    40

    104

    51

    7333M6x20

    7

    2.5

    40M635

    50188

    M6x20

    PUSH ACTION, AND-OF-STROKEBRACKETS A, B,C

    0 10 20 30 40

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    Stroke (mm)

    Kg 1.7 (N16)

    1 Kg = 9.81 Newtons

    Versions Voltages Circuits Brackets Optional Springs Electrical connections E4 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES4 pull-push action 2 = 24 V DC 2 = Series 2 B M2 F = Cables 3 = Series 3 C M3 V = Faston - screws

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • FAMILY E - ES 40

    C.E.I. srl

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    OPTIONAL SPRINGS

    SERIES 1 WITH INTERNAL SWITCH

    DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

    ELECTRICALCONNECTIONS

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES F

    BLUE

    L = 200 mm

    BY SCREWS V

    SCREWS

    PU

    LL C

    OIL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    RELE

    SERIES 3 WITHOUT INTERNAL SWITCH

    The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground. Designed for coupling with starter motor. Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

    ELECTRICALCONNECTIONS

    BY FASTONSMALL ANDLARGE

    FASTONCONNECTIONS

    BY CABLES F

    L = 200 mm

    BY SCREWS V

    SCREWS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    HP

    HP

    SERIES 2 WITH INTERNAL SWITCH

    ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

    ELECTRICALCONNECTIONS HOLD

    BLUEL = 200 mm

    PULLRED

    HOLD

    H = HOLDP = PULL

    H = HOLDP = PULL

    BLUEPULLRED

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY STARTER MOTOR

    OFFON

    START

    STARTER RELE

    STARTER MOTOR

    STARTER RELE

    K

    T P

    INTERNAL SPRING 4M1WIRE DIAMETER SPRING 1

    Kg 0.4 at 25 mm Kg 1.5

    INTERNAL SPRING 4M2WIRE DIAMETER SPRING 1.2

    Kg 0.9 at 25 mm Kg 3.0

    INTERNAL SPRING 4M3WIRE DIAMETER SPRING 1.3

    Kg 1.1 at 25 mm Kg 4.0

    BY CABLES F

    ACCESSORIES WITH M6 THREAD

    PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    SBJSPRING SWIVEL

    30

    AM6AXIAL ARTICULATED JOINT

    6

    6

    30

    T P

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    COMMONBLACK

  • FAMILY E - ES 50

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 41 A 23 A Hold current 0.50 A 0.28 A Duty service Continuous (100%) Stroke 40 mm Force at starting 4.3 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 1.18 Kg

    SPECIFICATIONS

    OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    0 10 20 30 40

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    Stroke (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

    0 10 20 30 40

    5

    10

    15DIAGRAMMA FORZA-CORSAForza (Kg)

    Corsa (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

    Versions Voltages Circuits Brackets Optional Springs Electrical connections E5 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES5 pull-push action 2 = 24 V DC 2 = Series 2 B M2 F = Cables 3 = Series 3 C (series 3) M3 V = Faston - screws M4 (external)

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    BRACKET A BRACKET B BRACKET C

    A

    VERSIONES

    B

    C

    50

    50 50

    7.3

    7.5

    63

    30 80 2.5

    52

    36

    7535

    52 38 28

    38

    BRACKETS A, B, C

    8035

    50199

    M6

    2.5

    M6x20

    M6x20

    1026220 75-358021

    79,5

    M6x20

    50 97

    56

    9

  • FAMILY E - ES 50

    C.E.I. srl

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTIONELECTRIC CIRCUITS FOR DIESEL ENGINES

    OPTIONAL SPRINGS

    SERIES 1 WITH INTERNAL SWITCH

    DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

    ELECTRICALCONNECTIONS

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES F

    BLUE

    L = 200 mm

    BY SCREWS V

    SCREWS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    RELE

    SERIES 3 WITHOUT INTERNAL SWITCH

    The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground. Designed for coupling with starter motor. Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

    ELECTRICALCONNECTIONS

    BY FASTONSMALL ANDLARGE

    FASTONCONNECTIONS

    BY CABLES F

    L = 200 mm

    BY SCREWS V

    SCREWS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    HP

    HP

    SERIES 2 WITH INTERNAL SWITCH

    ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

    ELECTRICALCONNECTIONS HOLD

    BLUEL = 200 mm

    PULLRED

    PULL

    H = HOLDP = PULL

    H = HOLDP = PULL

    RED

    HOLDBLUE

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFFON

    START

    K

    T P

    INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

    Kg 0.3 Kg 1.5

    INTERNAL SPRING 5M2WIRE DIAMETER SPRING 1.25

    Kg 0.4 Kg 2.5

    INTERNAL SPRING 5M3WIRE DIAMETER SPRING 1.45

    Kg 2.6 Kg 6.0

    EXTERNAL SPRING 5M4

    Kg 4.2 Kg 6.0

    STARTER MOTOR

    STARTER RELE

    STARTER MOTOR

    STARTER RELE

    BY CABLES F

    ACCESSORIES WITH M6 THREAD

    PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    SBJSPRING SWIVEL

    30

    AM6AXIAL ARTICULATED JOINT

    6

    6

    30

    T P

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    COMMONBLACK

  • C.E.I. srl

    OPERATIONThe solenoid has two windings:1) An intermittent-service pulling winding involved in the

    initial phase for approximately 150 ms, with the function of moving the plunger.

    2) A continuous-service holding winding, with the function of maintaining the plunger in position.

    For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

    FAMILY E - ES 46DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    Versions Voltages Circuits Brackets Optional Springs Electrical connections

    E46 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Cables ES46 pull-push action 2 = 24 V DC 2 = Series 2 C M2 (only series 3) 3 = Series 3 C2 M3

    SPECIFICATIONS

    A

    VERSIONES

    A

    C

    C2

    SERIES 1-2INTERNALSWITCHING

    SERIES 3

    BRACKET A

    SERIES 1-2

    46

    46

    63

    97

    26

    26

    2.5

    2.5

    577

    7

    26

    M6x20

    M6x20

    SERIES 3

    46

    26 mm26 mm

    FOR PULLACTION

    FOR PUSHACTION

    153

    M6x20

    M6x10

    51

    63

    28 97 26

    57

    51

    BRACKET A

    SERIES 3EXTERNALSWITCHING

    BRACKET C

    59 38-64 7

    78 63,5

    M6x203

    46

    59 38-64

    M6x203

    46 95 76

    55

    7

    Rated voltage 12 V DC 24 V DC Pull current 40 A 23.5 A Hold current 0.60 A 0.30 A Duty service Continuous (100%) Stroke 26 mm Force at starting 7 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 0.81 Kg

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    0 4 8 12 16 20 24 28Stroke (mm)

    Kg 7 (N68)

    1 Kg = 9.81 Newtons

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • FAMILY E - ES 46

    C.E.I. srl

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    OPTIONAL SPRINGS

    SERIES 1 WITH INTERNAL SWITCH

    DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and --)In the version with cables these are blue.

    ELECTRICALCONNECTIONS

    BLUE

    BLUE

    L = 150 mm

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    RELE

    SERIES 3 WITHOUT INTERNAL SWITCH

    The connection of the solenoid is the same as for the Series 2 circuit and is distinguished by PULL and HOLD.In the version with cables, these are respectively red and blue. Designed for coupling with starter motor. Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

    ELECTRICALCONNECTIONS

    RED - PULL

    BLACK - COMMON

    BLUE - HOLD

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    SERIES 2 WITH INTERNAL SWITCH

    ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

    ELECTRICALCONNECTIONS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFFON

    START

    K

    T P

    INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

    Kg 0.700 Kg 1.5

    INTERNAL SPRING 5M2WIRE DIAMETER SPRING 1.25

    Kg 1.100 Kg 2.5

    INTERNAL SPRING 5M3WIRE DIAMETER SPRING 1.45

    Kg 3.800 Kg 6.0

    HOLDBLUE

    PULLRED

    L = 150 mm

    L = 150 mm

    STARTER MOTOR

    STARTER RELE

    STARTER MOTOR

    STARTER RELE

    BY CABLES

    BY CABLES

    BY CABLES

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    ACCESSORIES WITH M6 THREAD

    PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    SBJSPRING SWIVEL

    30

    AM6AXIAL ARTICULATED JOINT

    6

    6

    30

  • FAMILY E - ES 60

    A VERSIONES

    B

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 47 A 24.5 A Hold current 0.65 A 0.30 A Duty service Continuous (100%) Stroke 50 mm Force at starting 8.4 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 1.95 Kg

    SPECIFICATIONS

    OPERATIONThe solenoid has two windings:An intermittent-service pulling winding involved in the initial phase for approximately 150 ms, with the function of moving the plunger.A continuous-service holding winding, with the function of maintaining the plunger in position.For a proper operation of the solenoid, it is indispensable for the plunger to reach end of travel and to obtain the perfect adherence to the bottom.

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    BRACKETA BRACKET B

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTION

    63

    55 38 2.5

    33

    M8x20

    M8x20

    30 124 74

    7.3

    60 60

    60

    93 5090 404 8.5

    30

    70

    44PUSH ACTION, AND-OF-STROKEBRACKETS A, B

    50

    35

    M6

    93

    219

    DIAGRAM OF FORCES AND STROKES

    252015105

    Force (Kg)

    0 10 20 30 40 50Stroke (mm)

    Kg 8.4 (N82)

    0 10 20 30 40

    5

    10

    15DIAGRAMMA FORZA-CORSAForza (Kg)

    Corsa (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

    Versions Voltages Circuits Brackets Optional Springs Electrical connections E6 pull action 1 = 12 V DC 1 = Series 1 A M1 Standard Faston ES6 pull-push action 2 = 24 V DC 2 = Series 2 B M3 (external) F = Cables 3 = Series 3 V = Faston - screws

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • FAMILY E - ES 60

    C.E.I. srl

    DUAL COIL SOLENOID FOR PULL ACTION OR PULL-PUSH ACTIONELECTRIC CIRCUITS FOR DIESEL ENGINES

    OPTIONAL SPRINGS

    SERIES 1 WITH INTERNAL SWITCH

    DIRECT ELECTRIC CIRCUITThe solenoid connection is not conditioned by the polarity (+ and -)In the version with cables these are blue.

    ELECTRICALCONNECTIONS

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES F

    BLUE

    L = 200 mm

    BY SCREWS V

    SCREWS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    RELE

    SERIES 3 WITHOUT INTERNAL SWITCH

    The connection of the solenoid is the same as for the Series 2. The pull coil Pand the hold coil T are respectively marked PULL and HOLD.The negative common in the version with faston is at ground. Designed for coupling with starter motor. Designed for external switch (Code CEI IE04 - timed static electronic switch ideal for dusty or saline environments and in applications with repeated accelerations).

    ELECTRICALCONNECTIONS

    BY FASTONSMALL ANDLARGE

    FASTONCONNECTIONS

    BY CABLES F

    L = 200 mm

    BY SCREWS V

    SCREWS

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFF

    ON

    START

    HP

    HP

    SERIES 2 WITH INTERNAL SWITCH

    ELECTRIC CIRCUIT COMBINED WITH STARTER MOTORThe solenoid connection feeding the pull coil P and the hold coil T is marked with the indication PULL (red cable) and HOLD (blue cable). The body is connected to ground. The pull coil P is fed in parallel with the starter motor: the red cable connected to the positive of the starter motor and the blue cable connected to the positive of the key switch. The auxiliary switch K ensures disconnection of the coil P and prevents the possible damaging return of parasitic currents.

    ELECTRICALCONNECTIONS HOLD

    BLUEL = 200 mm

    PULLRED

    PULL

    H = HOLDP = PULL

    H = HOLDP = PULL

    RED

    HOLDBLUE

    PULL

    CO

    IL

    HO

    LD C

    OIL

    BATTERY

    OFFON

    START

    K

    T P

    INTERNAL SPRING 6M1

    Kg 0.500 Kg 1.5

    EXTERNAL SPRING 6M3

    Kg 5.000 Kg 12.05

    STARTER MOTOR

    STARTER RELE

    STARTER MOTOR

    STARTER RELE

    BY CABLES F

    T P

    ACCESSORIES WITH M8 THREAD

    30 8

    8

    6 CLE8UNI CLEVIS

    SM8AXIAL ARTICULATEDJOINT

    P8THREADED DOWELL = 45 mm

    SBJSPRING SWIVEL

    IM890 ARTICULATEDJOINT

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    COMMONBLACK

  • FAMILY D - DS 40

    A C

    B VERSIONDS

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 25 A 11 A Duty service Intermittent Stroke 40 mm Force at starting 1.7 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 0.74 Kg

    SPECIFICATIONS

    BRACKETA BRACKETB BRACKETC

    40

    95

    3222.5

    7333

    M6x20 7

    25

    5265

    340

    95

    51

    7333M6x20

    7

    2.5

    40

    95 7333M6x20

    7

    36

    52

    3

    40M635

    59188

    M6x20

    PUSH ACTION, AND-OF-STROKEBRACKETS A,B,C

    Versions Voltages Circuits Brackets Optional Springs Electrical connections D4 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS4 pull-push action 2 = 24 V DC B M2 F = Cables C

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    0 10 20 30 40

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    Stroke (mm)

    Kg 1.7 (N16)

    1 Kg = 9.81 Newtons

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

  • FAMILY D - DS 40

    C.E.I. srl

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

    SERIES D INTERMITTENT

    ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

    ELECTRICALCONNECTIONS

    FOR STOP

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES FRED CABLES

    OPTIONAL SPRINGS

    INTERNAL SPRING 4M1 WIRE DIAMETER SPRING 1

    Kg 0.4 at 25mm Kg 1.5

    INTERNAL SPRING 4M2 WIRE DIAMETER SPRING 1.2

    Kg 0.9 at 25mm Kg 3.0

    EXAMPLE OF APPLICATION

    STOP

    SHUTDOWN LEVER TRAVEL

    RUNNINGPOSITION

    END-OF-STROKE

    L = 200 mm

    30

    6

    6

    30

    ACCESSORIES WITH M6 THREAD

    PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    AM6AXIAL ARTICULATED JOINT

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • AB

    VERSIONDS

    FAMILY D - DS 50

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 27 A 14.5 A Duty service Intermittent Stroke 40 mm Force at starting 4.3 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 1.17 Kg

    SPECIFICATIONS

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    0 10 20 30 40

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    Stroke (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

    Versions Voltages Circuits Brackets Optional Springs Electrical connections D5 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS5 pull-push action 2 = 24 V DC B M2 F = Cables

    BRACKETA BRACKETB

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    50

    50

    50

    7.3

    7.5

    63

    21 80

    52

    36

    7535

    43 38 28

    38BRACKETS A, B

    8035

    59199

    M6

    2.5

    2.5

    M6x20

    M6x20

    1026220

    OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

    RUNNINGPOSITION

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

  • FAMILY D - DS 50

    C.E.I. srl

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    INTERNAL SPRING 5M1WIRE DIAMETER SPRING 1

    Kg 0.3 Kg 1.5

    INTERNAL SPRING 5M2WIRE DIAMETER SPRING1.25

    Kg 0.4 Kg 2.5

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    SERIES D INTERMITTENT

    ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

    ELECTRICALCONNECTIONS

    OPTIONAL SPRINGS

    ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

    FOR STOP

    EXAMPLE OF APPLICATION

    STOP

    SHUTDOWN LEVER TRAVEL

    RUNNINGPOSITION

    END-OF-STROKE

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES FRED CABLES

    L = 200 mm

    30

    6

    6

    30

    ACCESSORIES WITH M6 THREAD

    PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    AM6AXIAL ARTICULATED JOINT

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • FAMILY D - DS 46

    C.E.I. srl

    Rated voltage 12 V DC 24 V DC Pull current 27 A 13 A Duty service Intermittent Stroke 26 mm Force at starting 7 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 0.74 Kg

    SPECIFICATIONS

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    Versions Voltages Circuits Brackets Optional Springs Electrical connections

    D46 pull action 1 = 12 V DC Series D A M1 Standard Cables DS46 pull-push action 2 = 24 V DC C M2

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    RUNNINGPOSITION

    BRACKET A BRACKET C

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

    A

    C

    VERSIONDS

    46

    26 mm26 mm

    FOR PULLACTION

    FOR PUSHACTION

    153

    M6x20

    M6x10

    4663

    97

    26

    2.5577

    26

    M6x20

    51

    59 38-64 7

    78 63,5

    M6x203

    46

    5

    10

    15DIAGRAM OF FORCES AND STROKESForce (Kg)

    0 4 8 12 16 20 24 28Stroke (mm)

    Kg 7 (N68)

    1 Kg = 9.81 Newtons

    0 10 20 30 40

    5

    10

    15DIAGRAMMA FORZA-CORSAForza (Kg)

    Corsa (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

  • FAMILY D - DS 46

    C.E.I. srl

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    INTERNAL SPRING 5M1 WIRE DIAMETER SPRING 1

    Kg 0.700 Kg 1.5

    INTERNAL SPRING 5M2 WIRE DIAMETER SPRING 1.25

    Kg 1.100 Kg 2.5

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    ACCESSORIES WITH M6 THREAD

    SERIES D INTERMITTENT

    ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and --).

    ELECTRICALCONNECTIONS

    OPTIONAL SPRINGS

    ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

    FOR STOP

    EXAMPLE OF APPLICATION

    STOP

    SHUTDOWN LEVER TRAVEL

    RUNNINGPOSITION

    END-OF-STROKE

    BY CABLES

    RED CABLES

    L = 150 mm

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    30

    6

    6

    30PW6THREADED DOWELM6 - 1/4 UNF L = 38 mm

    P6 THREADED DOWELL = 45 mm

    CLE6UNI CLEVIS

    SM6AXIAL ARTICULATEDJOINT

    IM690 ARTICULATEDJOINT

    AM6AXIAL ARTICULATED JOINT

  • FAMILY D - DS 60

    C.E.I. srl

    A

    B

    VERSIONDS

    Rated voltage 12 V DC 24 V DC Pull current 37 A 20 A Duty service Intermittent Stroke 50 mm Force at starting 8.4 Kg Windings insulation class H (180 C) Ambient temperature -40 C 120 C Weight 1.83 Kg

    SPECIFICATIONS

    00.4

    0.6

    0.8

    1.0

    1.2

    25 50 75 100 125 C

    FORCE VARIATION COEFFICIENT ACCORDINGWITH AMBIENT TEMPERATURE

    AMBIENT TEMPERATURE

    Versions Voltages Circuits Brackets Optional Springs Electrical connections D6 pull action 1 = 12 V DC 1 = Series D A M1 Standard Faston DS6 pull-push action 2 = 24 V DC B F = Cables

    BRACKET A BRACKETB

    63

    46 38 2.5

    33

    M8x20

    M8x20

    30 124 74

    7.3

    60 60

    60

    93 5090 404 8.5

    21

    70

    44PUSH ACTION, AND-OF-STROKEBRACKETS A, B

    50

    35

    M6

    93

    219

    DIAGRAM OF FORCES AND STROKES

    252015105

    Force (Kg)

    0 10 20 30 40 50Stroke (mm)

    Kg 8.4 (N82)

    0 10 20 30 40

    5

    10

    15DIAGRAMMA FORZA-CORSAForza (Kg)

    Corsa (mm)

    Kg 4.3 (N42)

    1 Kg = 9.81 Newtons

    OPERATIONThe single coil Elettrostart solenoids are for intermittent duty provinding high FORCE-STROKE pick-up. These solenoids are used to stop diesel engines when energized by actuating the fuel supply lever. The solenoid is de-energized when the engine is running, only in the stop phase it is energized cutting off the fuel flow.Due to its high operating power the energized time must not exceed one minute, while the de-energized time between two energizing phases must be long enough for the solenoid to cool down.

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    RUNNINGPOSITION

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

    AVAILABLE OPTIONSThe desired model has to be defined choosing one option in every column, building in this way the solenoid code.

  • FAMILY D - DS 60

    C.E.I. srl

    SINGLE COIL SOLENOID FOR INTERMITTENT DUTY

    INTERNAL SPRING 6M1

    Kg 0.500 Kg 1.5

    ELECTRIC CIRCUITS FOR DIESEL ENGINES

    SERIES D INTERMITTENT

    ELECTRIC CIRCUIT FOR INTERMITTENT DUTYThe solenoid connection is not conditioned by the polarity(+ and -).

    ELECTRICALCONNECTIONS

    OPTIONAL SPRING

    ENGINE WITH INJECTION PUMP NORMALLY OPENENGINE SHUTDOWN BY SOLENOID ENERGIZINGINTERMITTENT DUTY

    FOR STOP

    EXAMPLE OF APPLICATION

    STOP

    SHUTDOWN LEVER TRAVEL

    RUNNINGPOSITION

    END-OF-STROKE

    BY FASTON FASTON

    CONNECTIONS

    BY CABLES FRED CABLES

    L = 200 mm

    30 8

    8

    ACCESSORIES WITH M8 THREAD

    CLE8UNI CLEVIS

    SM8AXIAL ARTICULATEDJOINT

    P8THREADED DOWELL = 45 mm

    IM890 ARTICULATEDJOINT

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • MODELLO MODEL ES 50 SPECIAL

    SERIE SERIES 1 ES511AM4TG 12 V C.C.SERIE SERIES 1 ES521AM4TG 24 V C.C.SERIE SERIES 2 ES512AM4TG 12 V C.C.SERIE SERIES 2 ES522AM4TG 24 V C.C.SERIE SERIES 3 ES513AM4TG 12 V C.C.SERIE SERIES 3 ES523AM4TG 24 V C.C.

    Fili Cables L = 200 mm

    01234

    56789

    10111213141516

    32 24 16 8 0

    kg

    mm

    FORZA FORCE

    FORZA MAGNETICAMAGNETIC FORCEFORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA MOL

    LA

    FORCE OF SPRINGFO

    RZA DELLA MOLLA

    FORCE OF SPRING

    02468

    101214161820222426283032

    32 24 16 8 0

    kg

    mm

    FORZA FORCE

    FORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA M

    OLLA

    FORCE OF SPR

    ING

    FORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA M

    OLLA

    FORCE OF SPR

    ING

    FORZA MAGNETICA A INIZIO CORSA (32 mm) Kg 7 BOBINA DI POTENZA MAGNETIC FORCE AT START OF STROKE (32 mm) Kg 7 PULL COIL

    FORZA MAGNETICA DI MANTENIMENTO A CONTATTO (A FINE CORSA) Kg 18 HOLDING MAGNETIC FORCE ON DIRECT CONTACT (AT END OF STROKE) Kg 18 HOLD COIL

    FORZA MECCANICA DELLA MOLLA A INIZIO CORSA Kg 4.2 MECHANICAL FORCE OF THE SPRING AT START OF STROKE Kg 4.2

    FORZA MECCANICA DELLA MOLLA IN COMPRESSIONE Kg 6 MECHANICAL FORCE OF THE SPRING IN COMPRESSION Kg 6

    BOBINA DI MANTENIMENTO

    ESEMPIO DI CORSA DI 32 mm IN TRAZIONE O SPINTA EXAMPLE OF STROKE OF 32 mm FOR PULL OR PUSH

    82 mm

    50 mm

    PER AZIONE DI SPINTAFOR PUSH ACTION

    PER AZIONE DI TRAZIONEFOR PULL ACTION

    C.E.I. srl

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • MODELLO MODEL ES 60 SPECIAL

    SERIE SERIES 1 ES611AM3TG 12 V C.C.SERIE SERIES 1 ES621AM3TG 24 V C.C.SERIE SERIES 2 ES612AM3TG 12 V C.C.SERIE SERIES 2 ES622AM3TG 24 V C.C.SERIE SERIES 3 ES613AM3TG 12 V C.C.SERIE SERIES 3 ES623AM3TG 24 V C.C.

    Fili Cables L = 200 mm

    01234

    56789

    10111213141516

    32 24 16 8 0

    kg

    mm

    FORZA FORCE

    FORZA MAGNETICAMAGNETIC FORCEFORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA MOL

    LA

    FORCE OF SPRINGFO

    RZA DELLA MOLLA

    FORCE OF SPRING

    02468

    101214161820222426283032

    32 24 16 8 0

    kg

    mm

    FORZA FORCE

    FORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA M

    OLLA

    FORCE OF SPR

    ING

    FORZA MAGNETICAMAGNETIC FORCE

    FORZA DELLA M

    OLLA

    FORCE OF SPR

    ING

    FORZA MAGNETICA A INIZIO CORSA (32 mm) Kg 10 BOBINA DI POTENZA MAGNETIC FORCE AT START OF STROKE (32 mm) Kg 10 PULL COIL

    FORZA MAGNETICA DI MANTENIMENTO A CONTATTO (A FINE CORSA) Kg 25 HOLDING MAGNETIC FORCE ON DIRECT CONTACT (AT END OF STROKE) Kg 25 HOLD COIL

    FORZA MECCANICA DELLA MOLLA A INIZIO CORSA Kg 5 MECHANICAL FORCE OF THE SPRING AT START OF STROKE Kg 5

    FORZA MECCANICA DELLA MOLLA IN COMPRESSIONE Kg 12 MECHANICAL FORCE OF THE SPRING IN COMPRESSION Kg 12

    BOBINA DI MANTENIMENTO

    ESEMPIO DI CORSA DI 32 mm IN TRAZIONE O SPINTA EXAMPLE OF STROKE OF 32 mm FOR PULL OR PUSH

    90 mm

    60mm

    PER AZIONE DI SPINTAFOR PUSH ACTION

    PER AZIONE DI TRAZIONEFOR PULL ACTION

    C.E.I. srl

    C O S T R U Z I O N I E L E T T R O M A G N E T I C H E I N D U S T R I A L ICORSO PRIMO LEVI, 7 - 10090 CASCINE VICA - RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it

  • MAX FREQUENZE DI UTILIZZOUso continuo: 3 cicli/minutoUso intermittente: 10 cicli/minuto (max 5 min.)

    MAX ON-OFF DUTY CYCLESContinuous: 3 cycles/minuteIntermittent: 10 cycles/minute (max 5 min.)

    DESCRIZIONELIE04 un interruttore elettronico statico temporizzato con un circuito unico adeguato per 12 e 24 Volts. E adatto per il comando di ELETTROSTART doppia bobina con circuito elet-trico SERIE 3 senza interruttore impiegati per lo stop e per le accelerazioni dei motori diesel.Esso alimenta contemporaneamente le due bobine (PULL e HOLD) e dopo 500 millisecondi disinserisce la bobina PULL evitando il suo surriscaldamento.La sua applicazione presenta vantaggi meccanici ed elettrici:Incasodierrataregistrazioneobloccodeileveraggirimane

    inserita la sola bobina di mantenimento evitando il danneg-giamento del solenoide.

    Sostituiscelinterruttoreinternodelsolenoidepocoadattoinambienti polverosi o salini (grazie alla sua costruzione sta-gna) e nelle applicazioni con accelerazioni ripetute, garan-tendo una maggiore affidabilit e durata del solenoide.

    Di dimensioni e peso contenuti, pu essere agevolmenteposizionato in qualsiasi punto del motore.

    SPECIFICATIONThe IE04 is a timed static electronic switch with a single circuit suitable for 12 and 24 V. It is designed for control of dual coil ELETTROSTART with SERIES 3 electrical circuit without switch, used for the shutdown and acceleration of diesel engines. It supplies simultaneously the two coils (PULL and HOLD), and after 500 milliseconds it de-energizes the PULL coil, thus preventing it from overheating. Its application presents both mechanical and electrical advantages:In theeventof incorrectadjustmentorblockingof thecom-

    pound levers, only the HOLD coil remains energized, so preventing damage to the solenoid;

    It replaces the internal switchof the solenoidwhich is notvery suitable industyor salineenvironments (thanks to itsperfectly tight construction) and in applications with involving repeated acceleration, and thus guarantees a greater reli-ability and longer service of the solenoid;

    Sincethedimensionsandweightarereduced,itcanbeeasilypositioned in any point of the engine.

    interruttore elettronico statico temporizzatoTIMED sTaTIc ElEcTronIc swITch

    scHema - esempioarranGEMEnT - EXaMPlE

    SPECIFICHEVoltaggio: 12-24 V 10%Max voltaggio non ripetitivo: 100 VMax corrente: 95 ACavi: 2,5 mm2 L = 300 mmPeso: 130 g

    SPECIFICATIONSVoltage: 12-24 V 10%Max voltage not repetitive: 100 VMax current: 95 ACables: 2,5 mm2 L = 300 mmWeight: 130 g

    Possibilit di saldare i cavi sullElettrostart senza montare il connettore.The cables can be welded to the Elettrostart avoiding the connector.

    Interruttore IE04

    c.e.i. srl

    c o s t r u z i o n i e l e t t r o m a G n e t i c H e i n D u s t r i a l iCORSO PRIMO LEVI, 7 - 10098 RIVOLI - TORINO (ITALY) - TEL. 0039 0119594446 - FAx. 0039 0119591357

    e-mail: [email protected] www.cei-italy.it