Emission spectroscopy (Mainly fluorescence spectroscopy) Reading : van Holde Chapter 11 Homework : due Wednesday, April 18 van Holde 11.2. 11.3, 11.4, 11.5, 11.6, 11.7; Midterm 2 : Friday, April 20 Overview: 1. What is fluorescence? (conceptual QM picture, fluorescence spectra, quantum yield, lifetimes) 2. One powerful application: Fluorescence microscopy 3. Solvent effects 4. FRET (what is it?, Förster radius, quenching, applications of FRET) 5. Linear polarization of fluorescence, rotational motion

Emission spectroscopy (Mainly fluorescence spectroscopy)

  • Upload
    oona

  • View
    66

  • Download
    0

Embed Size (px)

DESCRIPTION

Emission spectroscopy (Mainly fluorescence spectroscopy). Reading : van Holde Chapter 11 Homework : due Wednesday, April 18 van Holde 11.2. 11.3, 11.4, 11.5, 11.6, 11.7; Midterm 2 : Friday, April 20. Overview: - PowerPoint PPT Presentation

Citation preview

Page 1: Emission spectroscopy (Mainly fluorescence spectroscopy)

Emission spectroscopy(Mainly fluorescence spectroscopy)

Reading: van Holde Chapter 11

Homework: due Wednesday, April 18

van Holde 11.2. 11.3, 11.4, 11.5, 11.6, 11.7;

Midterm 2: Friday, April 20

Overview:

1. What is fluorescence? (conceptual QM picture, fluorescence spectra,

quantum yield, lifetimes)

2. One powerful application: Fluorescence microscopy

3. Solvent effects

4. FRET (what is it?, Förster radius, quenching, applications of FRET)

5. Linear polarization of fluorescence, rotational motion (tumbling), Perrin plots

Page 2: Emission spectroscopy (Mainly fluorescence spectroscopy)

Ground state and excited states of the electrons in the outermost occupied shell of a molecule.

There are different types of excited states (higher energy level states), depending on spin and angular momentum; here we will just talk about triplet and singlet states.

Two (highest energy) electrons in ground state

Emission spectroscopyConceptual Quantum mechanical picture

Quick quiz: Why is quantum mechanics called quantum mechanics?

Page 3: Emission spectroscopy (Mainly fluorescence spectroscopy)

Ground state

1. singlet

2. singlet

1. triplet

Abs

orp

tion

~ 1

0-15 s

Inte

rnal

co

nver

sion

~

10-1

2 s

Intersystem

crossing

~ 10-8 s

Non

-rad

iativ

e ~

10-8 s

Flu

ores

cenc

e

(wai

t tim

e) ~

10-8

s

No

n-r

ad

iativ

e

~1

02

to 1

0-1

1 s

Ph

osp

ho

rce

nce

(wa

it tim

e)

~ 1

02

to 1

0-4 s

Absorbance, Fluorescence and Phosphorescence

Different paths by which excited electrons can return to ground

state – only one path results in fluorescence. Molecules will

fluoresce if the emission process has a lifetime that is shorter

than the conversion to the triplet state or non-radiative loss of

energy.

Emission spectroscopyConceptual Quantum mechanical picture

Page 4: Emission spectroscopy (Mainly fluorescence spectroscopy)

Some Terminology

• Luminescence: Process, in which susceptible molecules emit light from electronically excited states created by either a physical (for example, absorption of light), mechanical (friction), or chemical mechanism.

• Photoluminescence: Generation of luminescence through excitation of a molecule by ultraviolet or visible light photons. Divided into two categories: fluorescence and phosphorescence, depending upon the electronic configuration of the excited state and the emission pathway.

• Fluorescence (emission from singlet state): Some atoms and molecules absorb light at a particular wavelength, and subsequently emit light of longer wavelength after a brief interval, termed the fluorescence lifetime, . Fluorescent molecules are called fluorophores.

• Phosphorescence (emission from triplet state): Similar to fluorescence, but with a much longer excited state lifetime.

Page 5: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence spectra

Absorption fluorescence

c

hhE

:(light)photon a ofEnergy

:Remember

absorption emission

In fluorescence, the return to the ground state (almost) always occurs from lowest state of excited state (0’-level).

h = 6.6·1034 J·s (Planck’s const.) … frequency

Page 6: Emission spectroscopy (Mainly fluorescence spectroscopy)

1. Excitation: Light-induced transition, molecule goes from ground state to an excited electronic & vibrational state.

2. Vibrational Relaxation: Molecule loses some energy, falls to lowest vibrational state, still in excited electronic state

3. Emission: Molecule returns to ground electronic state while emitting a higher wavelength (=lower energy) photon

Fluorescence spectra

Page 7: Emission spectroscopy (Mainly fluorescence spectroscopy)

1. Excitation Spectrum: Fluorescence intensity vs. wavelength used to excite transition resembles absorbance spectrum.

2. Emission Spectrum: Fluorescence intensity vs. wavelength emitted for transition back to ground state: red-shifted with respect to excitation spectrum.

3. Quantum Yield: Ratio of energy absorbed to that emitted (more in a bit).

Fluorescence spectra

Page 8: Emission spectroscopy (Mainly fluorescence spectroscopy)

Example: Fluorescein absorption and emission spectra

Stokes shift

Looking at the absorption and emission peaks:

Fluorescein absorbs in the blue/purple (~ 490 nm) and emits in the green (~516 nm).

Fluorescence spectra

White board example:

Looking at the fluorescein spectrum, what is the energy difference between the ground state and the excited singlet state in fluorescein?

Page 9: Emission spectroscopy (Mainly fluorescence spectroscopy)

Steady State/Frequency Domain Fluorescence Instrumentation

Dual monochromators, one for excitation and the other for emission.

Obtain an Excitation and an Emission Spectrum.

Page 10: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence decay, life-time, time-resolved fluorescence

Flash sample with brief (~ns) pulse of light at ex and follow intensity vs time at em

Absorption N(0) molecules with get excited.

Fluorescence intensity is proportional to number of excited molecules.

Flu

ores

cenc

e In

tens

ity

time

maxI

e

maxI

Decay of excited molecules is a first-order process, with lifetime. Decay can happen via three pathways:

i. Fluorescence with associated intrinsic lifetime o

ii. Conversion to triplet state (phosphorescence and non-radiative decay).

iii. Non-radiative decay.

t

kt

eI

eItI

tIkdt

tdI

)0(

)0()(

)()(

Page 11: Emission spectroscopy (Mainly fluorescence spectroscopy)

When light is absorbed, only a fraction of it is emitted via fluorescence; the rest of the excited molecules decay via other processes.

Quantum yield

0

# of quanta emitted by fluorescenceQ

# of total quanta absorbed

A

k

is lifetime of all molecules in excited state, 0 is intrinsic lifetime (lifetime of “fluorescence state”).

k, is fluorescence decay constant, A is Einstein coefficient

Corollary: Fluorescence intensity is proportional to product of absorptivity (exctinction coefficient) and quantum yield.

Page 12: Emission spectroscopy (Mainly fluorescence spectroscopy)

Experimental data - fluorescence lifetime

Flash lamp pulse

Get from slope

White board example:

If Q is 0.5 for this fluorophore, what is the fluorescence lifetime?

Page 13: Emission spectroscopy (Mainly fluorescence spectroscopy)

1. Incident Light Intensity, Io ()

More photons in = more photons out. Detector reads intensity, unlike absorbance.

2. Fraction of Light Absorbed, e() c l Depends on concentration, c; path length of optical cell, l; & molar extinction coefficient, e

3. Quantum Yield, F

Only emitted photons count.

4. Fractional Emission , f() Emission at a particular wavelength

5. Detector Efficiency , d() Wavelength-dependent instrumental factor.

6. Sensitivity, S Product of extinction coefficient and quantum yield

Factors Influencing Detected Fluorescence Intensity

F() = Io( · c · (· l · F · f( · d(

F = k · c · · F

F = k · c · S

Page 14: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescent amino acids

  Amino acid Lifetime

Absorption Fluorescence Intensity

Wavelength Exctinc. coeff.

max Wavelength

Quantum Yield

Intensity ~ max·

Tryptophan 2.6 ns 280 nm 5,600 348 nm 0.20 1120

Tyrosine 3.6 ns 274 nm 1,400 303 nm 0.1 140

Phenylalanine 6.4 ns 257 nm 200 282 nm . 0.04 8

• Three amino acid have intrinsic fluorescence

• Fluorescence of a folded protein is mixture of fluorescence from individual aromatic residues. Most of the emissions are due to excitation of tryptophan

• Tryptophan:

Highest exctinction coeff and highest quantum strongest fluorescence intensity.

Intensity, quantum yield, and wavelength of maximum fluorescence emission are very solvent dependent. Fluorescence spectrum shifts to shorter wavelength and intensity increases as polarity of the solvent surrounding the tryptophane residue decreases.

Tryptophan fluorescence can be quenched by neighboring protonated acidic groups such as Asp or Glu.

http://dwb.unl.edu/Teacher/NSF/C08/C08Links/pps99.cryst.bbk.ac.uk/projects/gmocz/fluor.htm

Page 15: Emission spectroscopy (Mainly fluorescence spectroscopy)

• Tyrosine Like tryptophan, has strong absorption bands at 280 nm. Tyrosine is a weaker emitter than tryptophan, but it may still contribute significantly to protein fluorescence because it usually present in larger numbers. The fluorescence from tyrosine can be easily quenched by nearby tryptophan residues because of energy transfer effects.

• Phenylalanine Only a benzene ring and a methylene group is weakly fluorescent (product of quantum yield and molar absorbtivity maximum is low. Phenylalanine fluorescence is observed only in the absence of both tyrosine and tryptophane.

Page 16: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence Excitation & Emission Spectra of

Aromatic Amino Acids

Absorption and Emission spectra of the aromatic amino acids in pH 7 in aqueous solutions (I. Gryczynski)

Page 17: Emission spectroscopy (Mainly fluorescence spectroscopy)

Hg – or Xe lamp

Collimating lens

Excitation filter

Specimen

Objective lens

Dichroic mirror

Emission filter

CameraSchematics from: http://www.ifr87.cnrs-gif.fr/pbc/imagerie/outils/micros/microimg/mictout.gif

Powerful application of fluorescence: Fluorescence microscopy(shown here: epi-fluorescence illumination)

Note: Photobleaching: Fluorophores will “die” after a while of intense illumination.

Hg – or Xe lamp

Collimating lens

Excitation filter

Specimen

Objective lens

Dichroic mirror

Emission filter

CameraSchematics from: http://www.ifr87.cnrs-gif.fr/pbc/imagerie/outils/micros/microimg/mictout.gif

Page 18: Emission spectroscopy (Mainly fluorescence spectroscopy)

Normal African Green Monkey Kidney Fibroblast Cells (CV-1) (from Olympus web page: http://www.olympusmicro.com). Immunofluorescently labeled with primary anti-tubulin mouse monoclonal antibodies followed by goat anti-mouse Fab fragments conjugated to Rhodamine Red-X. In addition, the specimen was stained with DAPI (targeting DNA in the nucleus).

Fluorescence microscopy

Page 19: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence microscopy

• Advantages:

– Can label selected features of a sample, eg. Nucleus, DNA, microtubules, specific proteins

– Can observe how those molecule behave over time.

– Can see (though not resolve) features on nanometer level, even single molecules.

Page 20: Emission spectroscopy (Mainly fluorescence spectroscopy)

Solvent effects

Solvents can affect the fluorescence emission spectrum hugely.

Emission wavelength can be shifted and quantum yield can change.

There are specific and general solvent effects.

Changing Fluorescence can be used to detect solvent interactions.

Specific solvent interaction:

2-anilinonaphthalene fluorescence was changed to high wavelength by replacing cyclohexan with ethanol. Ethanol forms hydrogen bond.

Specific solvent effects: A chemical reaction of the excited state with the solvent. Example: Hydrogen-bonds, acid-base interactions, charge transfer.

Page 21: Emission spectroscopy (Mainly fluorescence spectroscopy)

Solvent effects

H20

0rg

Putting a fluorophore from cyclohexan (low dielectric constant) into water

(high dielectric constant), shifts fluorescence to higher wavelengths.

Lower Lower E: E: E = hc/E = hc/ Emission at longer Emission at longer

Polarization Red-ShiftPolarization Red-Shift

General solvent effects: Fluorescence depends on polarizability of solvent

Increasing dielectric constant of solvent shifts usually fluorescence to

higher wavelength.

Polar interactions lower energy of excited state (stabilize excited state).

Page 22: Emission spectroscopy (Mainly fluorescence spectroscopy)

Quantum yield depends very much on environment

Qrel = 1.00

Qrel = 0.46

Qrel = 0.23

Application: Staining of DNA in gels.

Fluorophores with good DNA binding

affinities (often intercalation), extremely

large fluorescence enhancements upon

binding nucleic acids (some >1000-fold),

and negligible fluorescence for the free

dyes.

SYBR stained dsDNA gel. Excite with UV, emits in visible. (DNA/SYBR Green I complex: Q~0.8; ~300-fold increase over free dye)

Increased quantum yield upon binding Changing quantum yield upon binding

Page 23: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence resonance energy transfer (FRET)

When two fluorophores are close together it is possible that one of them absorbs the light (donor), then transfers the energy to the neighboring fluorophore (acceptor), which then emits the light.

The two conditions for this to happen are:

1. Transition dipole interaction between the two fluorophores (i.e., they need to be close together and aligned).

2. Significant overlap of the emission spectrum of the donor with the absorption spectrum of the acceptor.

Example: Fluorescein (donor) and Alexa-546 (acceptor):

Page 24: Emission spectroscopy (Mainly fluorescence spectroscopy)

The absorption and emisson spectra of some fluorophores

Good FRET pair

Page 25: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence resonance energy transfer (FRET)

Basically, FRET is a great method to determine the distance between two fluorophores (molecules) in the range of ~1-10 nm.

Clever example: Molecular Beacons (also: more later on quenching)

used to detect presence of a certain DNA sequence in solution or cells (show on white board).

transfer 6

0

1E

r1

R

Efficiency of transfer:

Close together FRET signal

Far apart (further than Förster radius) no FRET signal

r … D-A distance

R0 Förster radius

Page 26: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence energy resonance transfer (FRET)Donor-acceptor pairs

White board example:

a. What is the FRET efficiency for a fluorescein-rhodamine pair, that is 2.25 nm apart?

b. If excited with 488 nm light, what is the main emitted wavelength?

Page 27: Emission spectroscopy (Mainly fluorescence spectroscopy)

FRET Application:

Coexisting conformations of fibronectin in cell culture imaged using fluorescence resonance energy transfer, Baneyx et al., PNAS 98:14464, 2001

DA

Extended conformation: Donor and acceptor are far apart: no FRET (donor emits)

Folded conformation: Donor and acceptor are close FRET (acceptor emits)

Page 28: Emission spectroscopy (Mainly fluorescence spectroscopy)

FRET Detects FRET Detects CompactCompact and and ExtendedExtended Fibronectin Fibronectin Conformations in Cultured CellsConformations in Cultured Cells

Page 29: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorophore = fluorescein Quencher = dabcylFluorophore = fluorescein Quencher = dabcyl

QuenchingSome molecules are quenchers they suppress fluorescence when they are close to a fluorophore

Page 30: Emission spectroscopy (Mainly fluorescence spectroscopy)

Molecular Beacons & Fluorescence QuenchingMolecular Beacons & Fluorescence Quenching

Quenched

no light

Not quenched light

Page 31: Emission spectroscopy (Mainly fluorescence spectroscopy)

Linear polarization of fluorescence Light to excite fluorophore is now linearly polarized

Emitted fluorescent light will be depolarized

(De-)Polarization of emitted light depends on:1. Orientation of emitting transition dipole relative to absorbing transition dipole2. Amount of molecular rotation during fluorescent lifetime! Depolarization of emitted light

Absorption is best for those molecules whose transition dipole is parallel to plane of polarization.

Page 32: Emission spectroscopy (Mainly fluorescence spectroscopy)

Fluorescence anisotropy:

I Ir=

I 2I

1. Assume molecules don’t rotate while being excited

depolarization due only to random orientation of molecules with respect to incoming light, , and angle

Depolarization is described in terms of:

20

1r ( 3cos 1)

5

If there is no molecular rotation, anisotropy will vary between 2/5 (absorbing and emitting trans. dipoles are parallel) and-1/5 (dipoles are perpendicular).

Anisotropy for fluorescence of rhodamine as a function of of exciting light

Linear polarization of fluorescence

Page 33: Emission spectroscopy (Mainly fluorescence spectroscopy)

2. Now assume molecules tumble (rotate) before emitting.

depolarization due rotation of molecules.

Two extremes: i) molecules don’t rotate before emission r = r0

ii) molecules randomly orient before emitting: r = 0

Time-resolved fluorescence provides a convenient way to measure rotational motion of biological molecules.

t /0r t r e

… correlation time

information about size &shape of molecule

large slow tumbling large molecular weight

Flu

or. a

niso

trop

y r

time

0r

e

0r

Linear polarization of fluorescence

Page 34: Emission spectroscopy (Mainly fluorescence spectroscopy)

How long for BSA to “tumble”?How long for BSA to “tumble”?

Rotational Correlation Time:Rotational Correlation Time:

= V = V / k T = / k T = ((8.1E-20)*(0.01) / [1.38E-16 * 293]8.1E-20)*(0.01) / [1.38E-16 * 293]

= = 2.0E-8 sec = 20 nsec2.0E-8 sec = 20 nsec

BSA rotates in ~ 10 - 20 nanonsecondsBSA rotates in ~ 10 - 20 nanonsecondsFluorescent lifetime ~ 5 nanosecondsFluorescent lifetime ~ 5 nanoseconds

Example: rotational correlation time for BSA Example: rotational correlation time for BSA Mol Wt = 66,500 grams/moleMol Wt = 66,500 grams/mole

DDrotrot = 8.3E6 sec-1 = 8.3E6 sec-1

Page 35: Emission spectroscopy (Mainly fluorescence spectroscopy)

Large slow rotation large molecule

Small faster rotation compact molecule

Linear polarization of fluorescence

Page 36: Emission spectroscopy (Mainly fluorescence spectroscopy)

Perrin plotsInstead of pulse illumination, use continuous illumination to measure anisotropy will get average anisotropy ravg.

HW 11.6

B

0

k T1 11

r r V T

… lifetime

… viscosity

T … temperature

V … volume of molecule

1

r

T

T

B

0

kslope:

r V

0

1intercept:

r

Page 37: Emission spectroscopy (Mainly fluorescence spectroscopy)

Applications of fluorescence to proteins

• Fluorescence microscopy

• Analytical detection of presence of proteins

• Monitor changes in quantum yield as indication of changing

environment (binding, unfolding, etc.)

• Effects of energy transfer (FRET). Determine distance of

fluorescent groups from each other in 1-10 nm range.

• Changes in fluorescence polarization to determine shape and size

of molecules (tumbling depends on shape and size)

• Monitor (change) in fluorescence parameters to determine

stoichiometry, presence of intermediates, binding constants, etc.

Page 38: Emission spectroscopy (Mainly fluorescence spectroscopy)

Application of fluorescence to DNA

• Staining of oligonucleotides in gels• Monitoring the unwinding of double-

stranded DNA helicase• Monitoring DNA melting

Also: there are tons of reactive fluorophores that can be used to label proteins (Cysteines, primary amines, etc) and DNA.

See: Molecular Probes, Inc.

http://probes.invitrogen.com/