SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add- In Operating Manual Valid for: CMC software version 4.8 12/2017 A5E43099659B-AA Preface Safety notes 1 Requirements 2 Method of delivery and loading the EPLAN Add-in 3 Siemens DQ-Topo and submenus 4 Configuring with EPLAN Add- In 5 EPLAN adaptations 6 DRIVE-CLiQ types 7 Messages 8 List of abbreviations A Siemens Parts

EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Embed Size (px)

Citation preview

Page 1: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

SINUMERIK

SINUMERIK 840D sl / 828DSINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual

Valid for: CMC software version 4.8

12/2017A5E43099659B-AA

Preface

Safety notes 1

Requirements 2Method of delivery and loading the EPLAN Add-in 3Siemens DQ-Topo and submenus 4Configuring with EPLAN Add-In 5

EPLAN adaptations 6

DRIVE-CLiQ types 7

Messages 8

List of abbreviations A

Siemens Parts

Page 2: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Legal informationWarning notice system

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger.

DANGERindicates that death or severe personal injury will result if proper precautions are not taken.

WARNINGindicates that death or severe personal injury may result if proper precautions are not taken.

CAUTIONindicates that minor personal injury can result if proper precautions are not taken.

NOTICEindicates that property damage can result if proper precautions are not taken.If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified PersonnelThe product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems.

Proper use of Siemens productsNote the following:

WARNINGSiemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed.

TrademarksAll names identified by ® are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of LiabilityWe have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AGDivision Digital FactoryPostfach 48 4890026 NÜRNBERGGERMANY

A5E43099659B-AAⓅ 12/2017 Subject to change

Copyright © Siemens AG 2017.All rights reserved

Page 3: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Preface

SINUMERIK documentation The SINUMERIK documentation is organized into the following categories:

● General documentation/catalogs

● User documentation

● Manufacturer/service documentation

Additional informationYou can find information on the following topics at the following address (https://support.industry.siemens.com/cs/de/en/view/108464614):

● Ordering documentation/overview of documentation

● Additional links to download documents

● Using documentation online (find and search in manuals/information)

If you have any questions regarding the technical documentation (e.g. suggestions, corrections), please send an e-mail to the following address (mailto:[email protected]).

mySupport/DocumentationAt the following address (https://support.industry.siemens.com/My/ww/en/documentation), you can find information on how to create your own individual documentation based on Siemens' content, and adapt it for your own machine documentation.

TrainingAt the following address (http://www.siemens.com/sitrain), you can find information about SITRAIN (Siemens training on products, systems and solutions for automation and drives).

FAQsYou can find Frequently Asked Questions in the Service&Support pages under Product Support (https://support.industry.siemens.com/cs/de/en/ps/faq).

SINUMERIKYou can find information about SINUMERIK at the following address (http://www.siemens.com/sinumerik).

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 3

Siemens Parts

Page 4: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Target groupThis publication is intended for machine operators using EPLAN.

There is also basic information for administrators who, for example, install EPLAN Add-In.

BenefitsA SINAMICS topology configured in EPLAN can be used in Create MyConfig Topo.

The SINAMICS topology is exported to EPLAN electric P8 as a file via the "Siemens DQ-Topo" Add-In. This output file is imported for further use in Create MyConfig Topo. The data already configured for the production of a machine can therefore continue to be used with immediate effect in CMC.

Purpose of the documentThis document describes the use of the EPLAN Add-In "Siemens DQ-Topo".

Standard scopeThis documentation only describes the functionality of the standard scope. Additions or revisions made by the machine manufacturer are documented by the machine manufacturer.

Other functions not described in this documentation might be executable in the control. This does not, however, represent an obligation to supply such functions with a new control or when servicing.

Furthermore, for the sake of clarity, this documentation does not contain all detailed information about all product types and cannot cover every conceivable case of installation, operation or maintenance.

Technical SupportCountry-specific telephone numbers for technical support are provided in the Internet at the following address (https://support.industry.siemens.com/sc/ww/en/sc/2090) in the "Contact" area.

Preface

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In4 Operating Manual, 12/2017, A5E43099659B-AA

Page 5: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Table of contents

Preface.........................................................................................................................................................3

1 Safety notes..................................................................................................................................................7

1.1 Fundamental safety instructions..............................................................................................71.1.1 General safety instructions.......................................................................................................71.1.1.1 Danger to life if the safety instructions and residual risks are not observed............................71.1.1.2 Malfunctions of the machine as a result of incorrect or changed parameter settings..............71.1.2 Warranty and liability for application examples........................................................................71.1.3 Industrial security.....................................................................................................................8

2 Requirements...............................................................................................................................................9

3 Method of delivery and loading the EPLAN Add-in....................................................................................11

3.1 Method of delivery..................................................................................................................11

3.2 Loading the EPLAN Add-In....................................................................................................12

4 Siemens DQ-Topo and submenus.............................................................................................................15

5 Configuring with EPLAN Add-In.................................................................................................................17

5.1 Requirement...........................................................................................................................17

5.2 Settings..................................................................................................................................175.2.1 SINAMICS product catalog....................................................................................................175.2.2 Setting the path for the drive object list..................................................................................185.2.3 Defining unknown devices.....................................................................................................195.2.4 DRIVE-CLiQ configuration.....................................................................................................22

5.3 Define bus data......................................................................................................................225.3.1 Control master (NCU)............................................................................................................245.3.2 Expansion modules of the control..........................................................................................27

5.4 Assigning drive objects..........................................................................................................285.4.1 EPLAN devices......................................................................................................................285.4.2 Drive object list.......................................................................................................................295.4.3 Assignment of the DO component to the device component.................................................305.4.3.1 Assignment using drag-and-drop...........................................................................................305.4.3.2 Assignment via direct input....................................................................................................305.4.4 Filtering of EPLAN devices and drive objects........................................................................31

5.5 Exporting the DRIVE-CLiQ topology......................................................................................325.5.1 Requirement...........................................................................................................................325.5.2 Exporting the DRIVE-CLiQ topology......................................................................................33

5.6 Excluding devices from the export.........................................................................................34

5.7 Command line interface.........................................................................................................36

6 EPLAN adaptations....................................................................................................................................37

6.1 Settings via "Siemens DQ-Topo" add-in................................................................................37

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 5

Siemens Parts

Page 6: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

6.2 Minimum requirements in EPLAN regarding DRIVE-CLiQ topology......................................37

6.3 Minimum requirements in EPLAN regarding power topology................................................38

7 DRIVE-CLiQ types......................................................................................................................................41

8 Messages...................................................................................................................................................43

8.1 Drive objects..........................................................................................................................43

8.2 Errors.....................................................................................................................................43

8.3 Warnings................................................................................................................................45

A List of abbreviations....................................................................................................................................47

Index...........................................................................................................................................................49

Table of contents

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In6 Operating Manual, 12/2017, A5E43099659B-AA

Page 7: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Safety notes 11.1 Fundamental safety instructions

1.1.1 General safety instructions

1.1.1.1 Danger to life if the safety instructions and residual risks are not observed

WARNING

Danger to life if the safety instructions and residual risks are not observed

If the safety instructions and residual risks in the associated hardware documentation are not observed, accidents involving severe injuries or death can occur.● Observe the safety instructions given in the hardware documentation.● Consider the residual risks for the risk evaluation.

1.1.1.2 Malfunctions of the machine as a result of incorrect or changed parameter settings

WARNING

Malfunctions of the machine as a result of incorrect or changed parameter settings

As a result of incorrect or changed parameterization, machines can malfunction, which in turn can lead to injuries or death.● Protect the parameterization (parameter assignments) against unauthorized access.● Handle possible malfunctions by taking suitable measures, e.g. emergency stop or

emergency off.

1.1.2 Warranty and liability for application examplesThe application examples are not binding and do not claim to be complete regarding configuration, equipment or any eventuality which may arise. The application examples do not represent specific customer solutions, but are only intended to provide support for typical tasks. You are responsible for the proper operation of the described products. These application examples do not relieve you of your responsibility for safe handling when using, installing, operating and maintaining the equipment.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 7

Siemens Parts

Page 8: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

1.1.3 Industrial security

NoteIndustrial security

Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks.

In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept. Siemens products and solutions only represent one component of such a concept.

The customer is responsible for preventing unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place.

Additionally, Siemens’ guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit:

Industrial security (http://www.siemens.com/industrialsecurity).

Siemens’ products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer’s exposure to cyber threats.

To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed at:

Industrial security (http://www.siemens.com/industrialsecurity).

WARNING

Unsafe operating states resulting from software manipulation

Software manipulations (e.g. viruses, trojans, malware or worms) can cause unsafe operating states in your system that may lead to death, serious injury, and property damage.● Keep the software up to date. ● Incorporate the automation and drive components into a holistic, state-of-the-art industrial

security concept for the installation or machine.● Make sure that you include all installed products into the holistic industrial security concept.● Protect files stored on exchangeable storage media from malicious software by with

suitable protection measures, e.g. virus scanners.

Safety notes1.1 Fundamental safety instructions

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In8 Operating Manual, 12/2017, A5E43099659B-AA

Page 9: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Requirements 2In order to be able to use the EPLAN Add-In, you require the EPLAN functionality of the "API AddIns" interface.

EPLAN versionsThis documentation applies to the EPLAN Add-In version V1.9.

The EPLAN Add-In has been released for EPLAN electric P8 versions 2.3, 2.4 and 2.5.

The functionality of the Add-In is identical in all EPLAN versions. The only exception is the definition of the PLC bus properties. The differences in the definition of the bus properties are in the EPLAN software.

SINAMICS product catalogThe SINAMICS product catalog must be available and loaded. For further information on settings, refer to Section "SINAMICS product catalog" (Page 17).

A current version of the SINAMICS product catalog will be delivered with the EPLAN Add-In.

When unpacking "EPlanPlugin.zip", the catalog is stored in the default directory.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 9

Siemens Parts

Page 10: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Requirements

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In10 Operating Manual, 12/2017, A5E43099659B-AA

Page 11: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Method of delivery and loading the EPLAN Add-in 33.1 Method of delivery

The EPLAN Add-In is delivered as a ZIP file "EPlanPlugin.zip" with the DVD for Create MyConfig from version 4.8.

To load in EPLAN, unpack the EPLAN Add-In ZIP file in a directory of your choice.

RequirementYou require two licenses to use the EPLAN Add-In:

● One license to load and use the EPLAN Add-In in the platform "EPLAN Electric P8" and create the export file from EPLAN.

● A further license to import the export file from EPLAN with the DRIVE-CLiQ topology to Create MyConfig Topo.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 11

Siemens Parts

Page 12: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

3.2 Loading the EPLAN Add-InThe EPLAN Add-In is loaded via the "EPLAN Electric P8" platform.

1. Select "Utilities" > "API add-ins..." via the main menu.

Figure 3-1 EPLAN - Loading the Add-In

2. The "API modules (assemblies)" dialog opens.

3. Click the "Load" button.

Method of delivery and loading the EPLAN Add-in3.2 Loading the EPLAN Add-In

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In12 Operating Manual, 12/2017, A5E43099659B-AA

Page 13: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

4. Select the file "Siemens.EplAddIn.DQTopo.dll" from the directory into which you unpacked the EPLAN Add-In.

Figure 3-2 EPLAN dialog "API modules (assemblies)"

5. Confirm with "OK". Once you have successfully loaded the EPLAN Add-In, the "Siemens DQ-Topo" main menu is displayed.

Figure 3-3 New "Siemens DQ-Topo" main menu

Loading the EPLAN Add-In using the command lineYou will find information on how start the EPLAN Add-In using a command line in the Section "Command line interface" (Page 36).

Method of delivery and loading the EPLAN Add-in3.2 Loading the EPLAN Add-In

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 13

Siemens Parts

Page 14: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Method of delivery and loading the EPLAN Add-in3.2 Loading the EPLAN Add-In

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In14 Operating Manual, 12/2017, A5E43099659B-AA

Page 15: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Siemens DQ-Topo and submenus 4The "Siemens DQ-Topo" main menu has the following submenus:

Figure 4-1 "Siemens DQ-Topo" main menu

Further information on submenus is available under:

● Assigning drive objects (Page 28)

● Settings… (Page 17)

– SINAMICS product catalog (Page 17)

– DO list (Page 18)

– Device settings (Page 19)

– DRIVE-CLiQ type settings (Page 22)

Figure 4-2 "Settings..." dialog

● Export (Page 32)

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 15

Siemens Parts

Page 16: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Siemens DQ-Topo and submenus

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In16 Operating Manual, 12/2017, A5E43099659B-AA

Page 17: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Configuring with EPLAN Add-In 55.1 Requirement

Before exporting the configuration, check the following points in EPLAN:

● Make sure that the EPLAN article database has been filled with additional information, e.g. DRIVE-CLiQ type of devicesYou will find further information on this in Section DRIVE-CLiQ configuration (Page 22).

● Configure the bus data for the master modules.You will find further information in Section Defining bus data (Page 22).

● Make sure that the drive objects (DO) have been assigned.You will find further information in Section Assigning drive objects (Page 28).

5.2 Settings

5.2.1 SINAMICS product catalogThe storage location of the used SINAMICS product catalog can be set. You can specify the path via "Siemens DQ-Topo" > "Settings...".

Per default, the catalog is stored in the "SinamicsKompKatalogFilter" subdirectory when the EPLAN Add-In is installed.

The file name is "SINAMICS-DQ-Komponenten-Katalog.xml".

Figure 5-1 SINAMICS product catalog

Note

A valid catalog path is indicated by a red border to the path.

The current catalog version is displayed via the "Display catalog version" button.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 17

Siemens Parts

Page 18: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Import the catalogIf you click the "Import catalog" button in the "Settings" dialog, you automatically set the DRIVE-CLiQ type in the EPLAN article database for all SIEMENS devices defined in catalog.

A log file is generated during the import operation in which the errors are logged.

The "import-catalog.log.xml" file is located next to the "Siemens.EplAddIn.DQTopo.dll" EPLAN Add-In.

After completing the import, the results are displayed in a dialog.

Figure 5-2 Results of the catalog import

5.2.2 Setting the path for the drive object listYou can specify the path for the drive object list via "Siemens DQ-Topo" > "Settings...".

You have the following options to set the path at "DO list" in the "Settings…" dialog.

● Project path as output path (relative path)

● Setting an absolute path

Figure 5-3 Settings - path to the DO list

NoteTake the "*.uvdx" file extension into account

The DO list has the "*.uvdx" file extension.

If the path for the DO list has an incorrect file extension, this is indicated by a red border to the path.

Please note that a data type will be saved even if it is incorrect.

Configuring with EPLAN Add-In5.2 Settings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In18 Operating Manual, 12/2017, A5E43099659B-AA

Page 19: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Setting the project path as output path If you want to use the project directory as output path for the DO list:

1. Activate the "Using project directory as output directory" checkbox.After activation, an additional placeholder is set in front of the path of the DO list.

Figure 5-4 DO list: Project directory as output path

2. Enter the path to the DO list manually starting from the project directory.

Setting an absolute pathIf you want to set an absolute path for the DO list, proceed as follows:

1. Set an absolute path at "DO list" in the "Settings…" dialog if the "Using project directory as output directory" checkbox is deactivated.

2. Select the path and the required Drive object list via the button.

5.2.3 Defining unknown devicesUnknown devices are devices from third-parties or SIEMENS devices that are not defined in the catalog.

These devices are defined at "Device settings" in the "Settings..." dialog so that they can be detected and derived from the EPLAN Add-In.

Figure 5-5 "Settings…" dialog

Configuring with EPLAN Add-In5.2 Settings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 19

Siemens Parts

Page 20: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

ProcedureProceed as follows:

1. Click the "Define unknown devices" button.The dialog with the same name opens.

Figure 5-6 "Define unknown devices" dialog: Creating device definitions

2. Enter the "Order number" of the device.

3. Select whether it is a motor or sensor in the drop-down list at "DRIVE-CLiQ type".

Configuring with EPLAN Add-In5.2 Settings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In20 Operating Manual, 12/2017, A5E43099659B-AA

Page 21: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

4. Specify the number of subcomponents.

Note

If the number of components is set to "0" when selecting the DRIVE-CLiQ type, the field automatically becomes optional.

If the number of components is set to "1", e.g. for Sensor Modules, then a specification has to be made as to whether this can be a "Single" or "Double" Sensor Module.

The number of components is only relevant for Sensor and Terminal Modules. For other types, the number is set automatically to "0".Two subcomponents of the same type are available for "Fail-safe Terminal Modules" or "SMC40" and similar third-party devices.

5. The button opens a further dialog in which you can define the relevant connections of the third-party device in detail.

Figure 5-7 "Define unknown devices": Connection list of a device definition

The connections to be defined are read from the SINAMICS product catalog based on similar device types from SIEMENS.Possible port types are:

– Analog for encoder connection

– DRIVE-CLiQ

– Current

After "Save and close" of the dialogs, including the "Settings…" main dialog, the EPLAN article database is updated with the device types.

NoteUpdating changes in the project

In order that the changed "Settings…" can be used in the available projects, the changes must be compared to the EPLAN article database and then taken into the project.

Configuring with EPLAN Add-In5.2 Settings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 21

Siemens Parts

Page 22: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.2.4 DRIVE-CLiQ configurationIn the "Settings…" dialog at "DRIVE-CLiQ type settings", specify the mapping for the attributes in the "EPLAN property" field.

Figure 5-8 Settings - DRIVE-CLiQ type settings

Predefined EPLAN propertiesThe following attributes are already mapped per default in the "EPLAN property" field:

Table 5-1 Settings mapped on "EPLAN properties"

Configuration option Description Predefined "EPLAN proper‐ties"

Order number This attribute reads the order number for the article. If a Sie‐mens article was determined based on the order number, the ports apply as described in the following sections.

Order number

Device type This attribute determines the device type. The device type is required to determine the DQ topology.If the device type is missing and a connection is made to a DQ device type, an error message is issued.

Function group

Drive object - assignment The drive object assignment and the component assignment are saved in this attribute.

Additional field [1] – lan‐guage-neutral

5.3 Define bus data

NoteTake the EPLAN version into account

The EPLAN Add-In supports the evaluation and the export of the bus data as of EPLAN version 2.4.

Requirement

Take the following requirements into account:● The bus data is configured in EPLAN for each connection.

● Set the display type of the connection to "Single-pole" so that you can enter the bus data in the "Bus data" tab of the connection.

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In22 Operating Manual, 12/2017, A5E43099659B-AA

Page 23: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

● The device is considered from the viewpoint of EPLAN Add-In.You will find further information on this in Section Requirement (Page 32).

● Always display the device as PLC unit.

● The connections with the corresponding bus data are exclusively of the "PLC connection point and bus port" type.

● Only bus data of the "Profibus" and "Profinet" type is taken into account.

● The value of the EPLAN property "MasterSystemID" must be an integer.

● The EPLAN property "Position / Node ID" must be an integer. Use the "Position" instead of the IP address for Profinet.

NoteBus data - Internal/external PROFIBUS connection

Note that the bus data for the internal PROFIBUS connection of the NXs on the NCU is not configured because it has already been permanently defined.

Configure the external PROFINET connection and the PROFINET interface.

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 23

Siemens Parts

Page 24: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Overview of the EPLAN bus dataDisplay and information in the "Properties (components): PLC connection points and bus ports" dialog.

Figure 5-9 EPLAN Bus data

5.3.1 Control master (NCU)Define the following bus data for the bus connections of the control master (NCU):

● Bus master / Bus coupler

● Bus system: Bus system type

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In24 Operating Manual, 12/2017, A5E43099659B-AA

Page 25: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

● Position / Node ID: The position of the master on the respective bus.

● Property name "MasterSystemID": Bus number

Procedure

You define the bus data in the "Properties (components): PLC connection points and bus ports" dialog > "Bus data" tab.1. Select an object in EPLAN, e.g. a port.

2. Double-click the object. The "Properties (components): PLC connection points and bus ports" dialog opens.

3. Select the "Bus data" tab.

4. Define the bus data. Information on this is provided in the following examples for the NCU connections.

5. Confirm the changes via the "OK" button.

Configuring bus data for NCUExamples are listed below on how you can configure the NCU with various connections.

Example of the NCU connection X126

Bus master / Bus coupler = e.g. "NCU-DP"Bus system = "Profibus"Position / Node ID = "2" (defined value) MasterSystemID = "1" (defined value of the bus number)Master ID Set; the checkbox is activated.

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 25

Siemens Parts

Page 26: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Figure 5-10 Example - configuring bus data for the NCU

Example of the NCU connection X136

Bus master / Bus coupler = e.g. "NCU-MPI/DP"Bus system = "Profibus"Position / Node ID = "2" (defined value) MasterSystemID = "2" (defined value of the bus number)Master ID Set; the checkbox is activated.

Example of the NCU connection X150 P1

Bus master / Bus coupler = e.g. "NCU-PN/IO"Bus system = "Profinet"Position / Node ID = e.g. "2"MasterSystemID = e.g. "100" (value of the bus number)Master ID Set; the checkbox is activated.

NoteX150 connections

Only one of the two "X150" connections has to be configured because logically they represent the same PROFINET interface.

If both connections are configured, the configurations must match.

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In26 Operating Manual, 12/2017, A5E43099659B-AA

Page 27: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.3.2 Expansion modules of the control

Configure the expansion modules (slaves) and external CUs as follows:● Bus master / Bus coupler: Use the same value as already defined for the master.

● Position / Node ID: Enter the "Slave address" or the "Slave position".

● Master ID: The checkbox remains deactivated because the "Master ID" will not be set.

The "MasterSystemID" is not configured because it is determined automatically. The value defined on the master is used based on the value of the "Bus master / Bus coupler".

Figure 5-11 Example - external configuration - CU slave

Configuring with EPLAN Add-In5.3 Define bus data

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 27

Siemens Parts

Page 28: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.4 Assigning drive objectsStart the function via the "Siemens DQ-Topo" > "Assign drive objects" main menu.

Figure 5-12 "Assign drive objects" dialog

The dialog is divided into two areas:● The devices of the active EPLAN project with the valid DRIVE-CLiQ type are displayed on

the left-hand side.You will find further information in Section "EPLAN devices" (Page 28).

● The Drive object list with the properties of the drive objects (DO) and the associated components are displayed on the right-hand side.You will find further information in Section "Drive object list" (Page 29).

5.4.1 EPLAN devicesThe item designation, the DRIVE-CLiQ type and descriptive information are displayed for each EPLAN device.

The information for SIEMENS devices is taken from the SINAMICS product catalog.

The component distribution according to the SINAMICS product catalog is displayed and defined for each Siemens device. This includes the component index, type, information on DRIVE-CLiQ and other ports.

You can find information on how you can integrate other unknown devices in the topology in Section Defining unknown devices (Page 19).

Configuring with EPLAN Add-In5.4 Assigning drive objects

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In28 Operating Manual, 12/2017, A5E43099659B-AA

Page 29: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Additional informationAn additional component of the "CU link" type is displayed for each expandable master module .

Note

Assign a drive object component to all components of a device.

Messages that refer to the component distribution and set DRIVE-CLiQ type of a device are displayed below the device:

Figure 5-13 Assigning warnings and messages to drive objects - excerpt from "Assign drive objects" dialog, left-hand side

5.4.2 Drive object listThe following criteria must be satisfied so that the DO list can be read:

● The DO list is in the current project directory.

● The DO list is called "topo.uvdx".

You will find further information in Section "Settings" under "Setting the path for drive object list" (Page 18).

Figure 5-14 Structure of the DO list - excerpt from "Assign drive objects" dialog, right-hand side

All drive objects (DO) are listed on the first level. When a DO is selected, the associated components are listed.

Configuring with EPLAN Add-In5.4 Assigning drive objects

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 29

Siemens Parts

Page 30: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.4.3 Assignment of the DO component to the device component

5.4.3.1 Assignment using drag-and-dropYou can assign a DO component to a device component using drag-and-drop.

DO components have to be assigned to EPLAN device components for CMC. This assignment can be performed in EPLAN or subsequently in CMC.

Select the DO components from the DO list on the right-hand side in the "Assign drive objects" window so that you can assign them on the left-hand side of the EPLAN device components.

The following is an "NCU710" example:

Figure 5-15 Assigning DO components to device components in EPLAN by drag-and-drop

1. Select the required drive object (DO) in the "Assign drive objects" window on the right-hand side.

2. Click "DO name".The component list belonging to the DO opens.

3. Select the required DO component and drag it to the required component line below the device on the left-hand sideThe "Assigned drive object" and the "Assigned component" are displayed immediately.

4. After completing the assignment, you can confirm the changes via the "Apply" or "Save and close" button or reject them with the "Cancel" button.When the assignment has been accepted, the DO name and the component name are displayed in the preconfigured EPLAN property field for the appropriated devices. DO and component are displayed separated by a ">", e.g. "NCU710>NCU_01". If there are a number of subcomponents, they are separated by a semicolon.

5. If you want to delete an assignment, select the appropriate line of the device component and delete it via the "Del" key.

6. If you what to delete all assignments of a drive object, select the drive object and press the "Del" key.

5.4.3.2 Assignment via direct inputYou can also enter the DO component of a device component directly via the provided property field instead of using drag-and-drop (Page 30).

You will find further information on the standard use of the "EPLAN property" field in Section "Minimum requirements in EPLAN regarding DRIVE-CLiQ topology" (Page 37).

Configuring with EPLAN Add-In5.4 Assigning drive objects

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In30 Operating Manual, 12/2017, A5E43099659B-AA

Page 31: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Entries in the EPLAN property fieldsNote the following rules for entries in the EPLAN property fields:

● The DO variable is included in the DO list.

● The ">" separator must be used for the separation of the DO name and the DO component.

● Note the following XML rules when assigning DO variables:

Character XML< &lt;> &gt;& &amp;" &quot;' &apos;

● If the DO name includes the ">" separator, enter it as previously defined in the table.

DO assignment using the MOTOR example with precisely one DO assignment:"DMM_2>Mot_02"

Display: DO + motor

DO assignment using the MOTOR_WITH_ENCODER example with two DO assignments:"DMM_1>Mot_03>DMM_1>Enc_01"

Display: DO + motor + DO + encoder

5.4.4 Filtering of EPLAN devices and drive objects

Filtering of EPLAN devicesTo filter according to EPLAN devices, you have the following options:

● Filtering according to unassigned devices

● Filtering based on the entered device designation

Figure 5-16 Filtering devices

Configuring with EPLAN Add-In5.4 Assigning drive objects

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 31

Siemens Parts

Page 32: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Filtering of drive objectsTo filter according to drive objects, you have the following options:

● Filtering via the specified DO name

● Via the entered DO type

● Via the entered DO number

● Via the entered name of the axis

● Via the entered comment on the drive object

Figure 5-17 Filtering drive objects

5.5 Exporting the DRIVE-CLiQ topology

5.5.1 RequirementThe equipment parts list forms the basis for export with the following requirements:

● Select precisely one function as main function for each item designation.

● Store at least one article for each main function.

● Define a DRIVE-CLiQ type.

Device connection name

The connection name is determined according to the following algorithm:● Connector item designation property

● From the item designation of the connection function: The last section after the device item designation is relevant; identified by the ":" or "-" separator.

Examples

=Plant+location item desig‐nation:X100

→ X100

=Plant+location item desig‐nation-X1

→ X1

=Plant+location item desig‐nation DQ:X100

→ X100

The device connection name for the export of the DRIVE-CLiQ topology is defined by the SINAMICS product catalog or through the definition of an unknown device.

You can find further information about this in Section "Defining unknown devices" (Page 19).

Configuring with EPLAN Add-In5.5 Exporting the DRIVE-CLiQ topology

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In32 Operating Manual, 12/2017, A5E43099659B-AA

Page 33: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.5.2 Exporting the DRIVE-CLiQ topologyYou can export the DRIVE-CLiQ topology via the "Siemens DQ-Topo" > "Export" main menu.

This creates an export file from EPLAN. This export file is suitable for the further processing of the drive system configuration.

Figure 5-18 Exporting the DRIVE-CLiQ topology

NoteCreating an export file

To create a complete export file, note that the following requirements must be satisfied:● The drive objects have been assigned to the EPLAN devices

You will find information on this in Section Assigning drive objects (Page 28).● The bus data has been configured

You will find information in Section Defining bus data (Page 22).

Creating an export fileTo export the DRIVE-CLiQ topology, proceed as follows:

1. Select the required project.

2. With the option "Without/with DO list", you specify whether the DO list that has been used is also exported.

3. Name the output file, whose file type is "*.sdx".

4. Click the "Export" button to perform the export.

Configuring with EPLAN Add-In5.5 Exporting the DRIVE-CLiQ topology

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 33

Siemens Parts

Page 34: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5. A progress bar displays the currently performed operations.

6. After completing the export, a dialog displays the results of the export.

Figure 5-19 Export results

7. The "Open log file" button opens the log of the export operation.

8. You can correct any listed errors or warnings.You will find further information on this in Section Messages (Page 43).

Note"Without DO list" / "With DO list" options

With the "Without DO list" export, the DO assignment must be performed in Create MyConfig.

For this purpose, the DO list can also be read in separately in Create MyConfig Topo in addition to the "*.sdx".

If the "With DO list" option is used for the export, the DO list must be under the set path and must be valid. The DO list is then imported into Create MyConfig Topo.

5.6 Excluding devices from the exportCertain devices can be excluded from the export based on their display type.

Configuring with EPLAN Add-In5.6 Excluding devices from the export

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In34 Operating Manual, 12/2017, A5E43099659B-AA

Page 35: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

ProcedureTo exclude a device from the export, proceed as follows:

1. In the Add-In directory, open the file with the extension "Siemens.EplAddin.DQTopo.dll.eplan.config".This file is always automatically generated when a configuration is saved.

2. After opening the file, search for the appropriate key in the "ConfigurableFilterFunctions" tag.

Figure 5-20 Example setting

3. Then set the Value of the appropriate Key to "true".

Figure 5-21 Example setting: Active filter for all-pole devices

EPLAN display type - key assignmentIn the following table, the EPLAN display types have been assigned the appropriate keys:

EPLAN display type KeyAll-pole CircuitOverview OverviewPair cross-reference PairCrossReferenceSingle-pole CircuitSingleLineRI process picture ProcessAndInstrumentationDiagrammExternal ExternalGraphic Graphics

Mapping of EPLAN display type and the keys

Configuring with EPLAN Add-In5.6 Excluding devices from the export

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 35

Siemens Parts

Page 36: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

5.7 Command line interface

IntroductionYou can also start the EPLAN Add-In via a non-graphical user interface. The required command line parameters are transferred via a console. With successful execution of the action, the return value is "0".

Command syntaxThe EPLAN command line interface has the following syntax:

$Path $GeneralParameters $ActionName $ProjectName $OutputFile $ExportDOList

Placeholder Description Example$Path EPLAN is called via the "W3u.exe" which is

located in the EPLAN directory."C:\Program Files (x86)\EPLAN\Electric P8\2.4.4\Bin\W3u.exe"

$GeneralParameters For more detailed information and setting options, refer directly to EPLAN.

/NoSplash /Frame:0 /Auto /Quiet

$ActionName Name of the action to be executed. The name "SiemensDQTopoExport" has been defined for the export by the EPLAN Add-In.

SiemensDQTopoExport

$ProjectName Is available as parameter for the export ac‐tion in the form "/ParameterName:Parame‐terValue"

/PROJECTNAME:"C:\Users\Public\EPLAN\Data\projects\Company\EPLAN_project.elk"

$OutputFile Is available as parameter for the export ac‐tion in the form "/ParameterName:Parame‐terValue"

/OUTPUTFILE:"C:\Windows\Temp\Test.sdx"

$ExportDOList Is available as parameter for the export ac‐tion in the form "/ParameterName:Parame‐terValue"

/EXPORTDOLIST:1 Parameter value Description0 Without drive object list1 With drive object list

Command line interface – parameter list

Configuring with EPLAN Add-In5.7 Command line interface

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In36 Operating Manual, 12/2017, A5E43099659B-AA

Page 37: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

EPLAN adaptations 66.1 Settings via "Siemens DQ-Topo" add-in

The SINAMICS product catalog is selected and imported via the "Siemens DQ-Topo" add-in. The entries in the EPLAN database can be changed for export of the DQ configuration.

You will find further information on this in Section "Settings (Page 17)".

6.2 Minimum requirements in EPLAN regarding DRIVE-CLiQ topologyThe DRIVE-CLiQ topology describes the drive bus system. As with every bus system, the first step is to define a master module.

Master modulesThe DRIVE-CLiQ types (EPLAN database field) listed below are recognized as master modules:

Table 6-1 Master modules

DRIVE-CLiQ type Description and examplesSIMOTION_CX Controller Extension for SIMOTION D4x5/D4x5-2SINAMICS_CU Control Unit of SINAMICS S120, e.g. CU320/CU320-2SIMOTION_CPU Control Unit/Controller of SIMOTION C/D/PSIMOTION_CPU_C Controller of SIMOTION CSIMOTION_CPU_D Control Unit of SIMOTION D with SINAMICS CU320/CU320-2 integratedSIMOTION_CPU_P Control Unit of SIMOTION PSINUMERIK_NCU Numerical Control Unit of SINUMERIK 840D/840Dsl/828DSINUMERIK_NX Numerical Extension for SINUMERIK 840D/840Dsl/828D

Marking as a master module is specified via the DRIVE-CLiQ type entry.

Pre-defined DRIVE-CLiQ/encoder connection names

Pre-defined DRIVE-CLiQ connection names for SIEMENS devices:● X100, X101, X102, X103, X104, X105

● X200, X201, X202, X203, X204, X205

● X400, X401, X402

● X500, X500/1, X500/2, X501, X502, X503, X504, X505

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 37

Siemens Parts

Page 38: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Pre-defined encoder connection names for SIEMENS devices:● X100

● X520, X520/1, X520/2, X521, X531

● X261, X262, X2, Rail

NoteEvaluation error in DRIVE-CLiQ topology

If an error is recognized in the DRIVE-CLiQ topology, e.g. ring closure or duplicate wiring, the sub-topology is not output as of the corresponding control unit (NX or NCU).

HLA modulesNote the following during configuration of HLA modules:

● The analog connection of the HLA valve, which is connected to the HLA module, must have the name "X2".

● Represent the connection between the valve and the cylinder with standard power connections. The name of the connection is "X1".

HF modulesNote the following during configuration of HF modules:

● Configure the cross rail between the sine filter and damping module using a power connection. "Rail" is used as the connection name.

● As the cross rail between HF motor module and damping module is connected by DRIVE-CLiQ, no further configuration is required.

6.3 Minimum requirements in EPLAN regarding power topologyThe power topology describes the connections of the power supply of the modules and the supply for the motors.

Predefined item designation for the port designationThe following predefined item designations for the port designation are recognized in EPLAN:

● DCN

● DCP

● IC

● L1

● X1, X2, X3, X4, X5

EPLAN adaptations6.3 Minimum requirements in EPLAN regarding power topology

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In38 Operating Manual, 12/2017, A5E43099659B-AA

Page 39: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

● S1

● T1

NoteItem designation that EPLAN does not recognize

There is no search for the following item designations:● Item designation X24, +, M (Single Motor Module)● X124, i.e. not a power supply connection for SINAMICS CPU in the export file "example.sdx"

Entering the "DeviceName" tagWhen using a PLC unit as device representation, enter the tag "DeviceName" in the field "CPU: Name [1]" under the tab "PLC structure data".

Figure 6-1 "PLC structure data" tab, entry for "CPU: Name [1]"

When using an ancillary equipment unit for device representation, enter the tag "DeviceName" in the field "Function text" under the "Ancillary equipment unit" tab.

EPLAN adaptations6.3 Minimum requirements in EPLAN regarding power topology

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 39

Siemens Parts

Page 40: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Figure 6-2 "Ancillary equipment unit" tab, entry for "Function text"

EPLAN adaptations6.3 Minimum requirements in EPLAN regarding power topology

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In40 Operating Manual, 12/2017, A5E43099659B-AA

Page 41: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

DRIVE-CLiQ types 7The possible DRIVE-CLiQ types are listed below.

DRIVE-CLiQ type Description and examplesSINAMICS_CU Control Unit of SINAMICS S120, e.g. CU320/CU320-2SINUMERIK_NCU Numerical Control Unit of SINUMERIK 840D/840Dsl/828DSINUMERIK_NX Numerical Extension for SINUMERIK 840D/840Dsl/828DSINGLE_MOTOR_MODULE SINAMICS SMMSINGLE_MOTOR_MODULE_HF SINAMICS High Frequency SMMDOUBLE_MOTOR_MODULE SINAMICS DMM ENCODERSENSOR_MODULE SINAMICS SMC30, SME25VOLTAGE_SENSING_MODULE SINAMICS VSMDAMPING_MODULE SINAMICS Damping ModuleDAMPING_MODULE_HF SINAMICS High Frequency Damping ModuleADAPTER_MODULE SINAMICS AM600 of the SINAMICS S120MDQ_EXTENSION DRIVE-CLiQ Extension of the SINAMICS S120MHYBRID_CABINET_BUSHING SINAMICS S120MCAPACITOR_MODULE SINAMICS Capacitor ModuleACTIVE_LINE_MODULE SINAMICS ALMBASIC_LINE_MODULE SINAMICS BLMSMART_LINE_MODULE SINAMICS SLMACTIVE_INTERFACE_MODULE SINAMICS AIMPOWER_SUPPLY_EXTERNAL SITOP PSUPOWER_SUPPLY_INTEGRATED SINAMICS CSMCOMMUNICATION_BOARD SINAMICS CBE30TERMINAL_BOARD SINAMICS TB30TERMINAL_MODULE SINAMICS TM54F, TM15HUB_MODULE SINAMICS DMC20, DME20SINAMICS_S120M Distributed Drive System = Motor + MMSINAMICS_S120COMBI Drive System with 3/4 Combinated DrivesSINAMICS_S120COMBI3 Drive System with 3 Combinated Drives = 3xMM + 1xLM + 1xSMSINAMICS_S120COMBI4 Drive System with 4 Combinated Drives = 4xMM + 1xLM + 1xSMSMI SIMOTICS SMIDQI SIMOTICS DQIMOTOR_WITH_ENCODER motor with integrated encoder and analog cable to external sensor moduleDQ_ENCODER SIMOTICS DQE

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 41

Siemens Parts

Page 42: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

DRIVE-CLiQ type Description and examplesSINE_WAVE_FILTER_HF HF Sine Filter ModuleMOTOR_WITH_SENSOR_MOD‐ULE_AND_ENCODER*

DQI- / SMI-MotorCannot be used because EPLAN only permits a maximum of 30 characters in the article database and the rest are cut.

* Further information on the maximum length of the EPLAN text fields can be found in the EPLAN help > "Find" tab: "Article management: Field designations and field lengths of the article fields"

DRIVE-CLiQ types

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In42 Operating Manual, 12/2017, A5E43099659B-AA

Page 43: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Messages 8The EPLAN Add-In contains the following message types:

● Messages for Drive objects (Page 43)

● Errors (Page 43)

● Warnings (Page 45)

All messages are in alphabetical order in the respective list. The messages are described and contain a remedy.

8.1 Drive objectsList of the possible drive objects for which feedback is available.

The drive objects are listed in alphabetical order according to name and are described.

Drive object nameDescription RemedyDEVICE_TYPE_IS_INVALIDThe entered device type does not match the device type from the catalog.

Check and correct the device type.Alternatively, you can import the catalog and align the project.

DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNEDWhen the assigned drive object or component name has been assigned to several devices of components.

Check and correct the assignments.

DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LISTWhen the assigned drive object or component name has not been defined in the global DO list.

Check and correct the assignments.

DRIVEOBJECT_IS_UNASSIGNEDWhen a component of the device does not have an assigned drive object and/or component name.

Assign the drive object and component name to each other.

ERR_GLOBAL_DO_LIST_NOT_FOUNDA global DO list is missing. Create a global DO list in the project directory.

Or copy a DO list to the project directory.

8.2 ErrorsList of the possible errors for which feedback is available.

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 43

Siemens Parts

Page 44: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

The errors are listed in alphabetical order according to error designation and are described.

ErrorDescription RemedyDEVICE_TYPE_IS_EMPTYThe DRIVE-CLiQ type of a device in the DRIVE-CLiQ topol‐ogy is empty.Note If the device is not part of a topology, then this message is not an error.

Define a valid DRIVE-CLiQ type.

DEVICE_TYPE_IS_UNDEFINEDThe DRIVE-CLiQ type of a device in the DRIVE-CLiQ topol‐ogy has not been defined. NoteIf the device is not part of a topology, then this message is considered to be a warning.

Define a valid DRIVE-CLiQ type.

DRIVECLIQ_MULTIPLE_WIRINGTwo devices have been connected several times to each oth‐er in the DRIVE-CLiQ topology.

Delete one of the connections.

DRIVECLIQ_NO_MASTER_FOUNDA master module is missing in the DRIVE-CLiQ topology. Connect a master module (NCU).DRIVEOBJECT_FILE_IS_EMPTYThe file with the global drive objects is empty. Provide either a valid file or no file.DRIVEOBJECT_FILE_IS_INVALIDThe file with the global drive objects is damaged or corrupt and therefore cannot be read.

Provide either a valid file or no file.

ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_PORTA DRIVE-CLiQ port has either been assigned or connected several times.

Delete one of the connections.

ERR_MULTIPLE_DriveCLiQ_MASTERA DRIVE-CLiQ topology contains a number of master mod‐ules (NCUs).

● Remove a master module from the topology.● Or split the topology into two topologies.

ERR_RING_TOPOLOGYA DRIVE-CLiQ topology contains a ring connection. Break up the ring connection in the tree.EXCEPTION_READING_BOM_ENTRYAn unexpected exception has occurred while reading the EPLAN data for a device.

Please contact the Support with the listed exception. The problem may not be able to resolved by the user.

EXCEPTION_READING_SYSTEMCONFIGURATIONThe "SystemConfiguration.xml" file cannot be read. ● Check whether the rights for this file are available.

● Install the EPLAN Add-In again. Note that the unknown devices must then be defined again.

Messages8.2 Errors

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In44 Operating Manual, 12/2017, A5E43099659B-AA

Page 45: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

8.3 WarningsList of the possible warnings for which feedback is available.

The warnings are listed in alphabetical order and are described.

WarningsDescription RemedyBUS_DATA_IS_NOT_NUMERICThe bus data has not been defined numerically. In the "Properties (components): PLC connection points and

bus ports", enter a numeric value in the "Bus data" tab in the "Position / Node ID" data filed for the single-pole PLC con‐nector.

BUS_SYSTEMID_IS_DIFFERENTTwo different PROFINET networks are defined at two con‐nections of the device.

Unify the PROFINET data.

CONFIGURATION_COULD_NOT_READING / CONFIGURATION_UNAUTHORIZED_READINGThe configuration could not be read. 1. Correct the authorization error.

2. Delete the configuration files and save them again.CONFIGURATION_COULD_NOT_WRITING / CONFIGURATION_UNAUTHORIZED_WRITINGThe configuration could not be written. 1. Correct the authorization error.

2. Delete the configuration files and save them again.CONNECTION_HAS_SAME_DEVICE_ON_BOTH_ENDSThe connection goes to the same device. Change the connection to the correct device.CONNECTION_NOT_HOMOGENThe connection is between different types, e.g. DRIVE-CLiQ to Power.

Change the connection.

CONNECTION_TO_UNKNOWN_DEVICEThe connection goes to an unknown device. The signaled device is unknown:

● Because not listed in the SINAMICS product catalog● Not defined as unknown device● Because no order number available● No DRIVE-CLiQ type defined

CONNECTION_TO_UNKNOWN_PORTThe connection goes to an unknown port. Change the connection.

Or define the device as unknown device in order to specify the port name and the type.You can find further information in Section "Defining unknown devices" (Page 19).

DEVICE_EXISTS_MULTIPLE_TIMEThe device has more than one EPLAN main function? Select one EPLAN function as main function.DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGYThe DRIVE-CLiQ device is not contained in the DRIVE-CLiQ topology.

Integrate the device in the DRIVE-CLiQ topology.

DEVICE_ONLY_IN_POWERTOPOLOGYThe DRIVE-CLiQ device is only integrated in the power top‐ology.

Also integrate the device in the DRIVE-CLiQ topology.

Messages8.3 Warnings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 45

Siemens Parts

Page 46: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

WarningsDescription RemedyDRIVEOBJECT_COMPONENT_ALREADY_ASSIGNEDThe drive object (DO) has already been assigned to another device.

Make a unique assignment of the drive object (DO).

DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LISTThe assigned drive object is not contained in the global DO list.

Update the global DO list and adapt the assignment.

DRIVEOBJECT_ERROR_WHILE_READINGAn error occurred while reading the drive object assignments. The export will be continued without the relevant assignmens.

Contact the Support.DRIVEOBJECT_FILE_HAS_DUPLICATE_IDSDuplicates of DO names have been found in the global DO list.The IDs in the global DO list are the DO names.

Remove the duplicates from the global DO list.

UNKNOWN_ECAD_VERSIONBus data has not been implemented for the used EPLAN ver‐sion.

Use a different EPLAN version or contact the Support.

UNSUPPORTED_PROPERTY_TYPEThe EPLAN property for bus data has found an unsupported type. This warning can occur with unsupported EPLAN versions or when unsupported values have been entered.

Check the bus data or contact the Support.

Messages8.3 Warnings

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In46 Operating Manual, 12/2017, A5E43099659B-AA

Page 47: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

List of abbreviations AItem designation (EPLAN database field)CMC Create MyConfigCNC Computerized Numerical ControlCU Control unitDO Drive objectNC Numerical controlNCU Numerical Control Unit (example: NCU 720.2)

Table A-1 File extensions for the file formats used in EPLAN

*.sdx SiemensDataExchange files - export file for Create MyConfig Topo*.uvdx Extended DO list for Create MyConfig Topo

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 47

Siemens Parts

Page 48: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

List of abbreviations

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In48 Operating Manual, 12/2017, A5E43099659B-AA

Page 49: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

Index

**.sdx, 33*.uvdx, 18

AAncillary equipment unit

Device representation, 39Assigning DO

By drag-and-drop, 30Direct input, 30

Assigning drive objectsDialog, 28

BBenefits, 4Bus data

Control master, 24Defining, 24EPLAN version, 22NCU, 24Requirements, 22Tab, 24

BUS_DATA_IS_NOT_NUMERICWarning, 45

BUS_SYSTEMID_IS_DIFFERENTWarning, 45

CCommand syntax, 36CONFIGURATION_COULD_NOT_READING

Warning, 45CONFIGURATION_COULD_NOT_WRITING

Warning, 45CONFIGURATION_UNAUTHORIZED_READING

Warning, 45CONFIGURATION_UNAUTHORIZED_WRITING

Warning, 45CONNECTION_HAS_SAME_DEVICE_ON_BOTH_ENDS

Warning, 45CONNECTION_NOT_HOMOGEN

Warning, 45

CONNECTION_TO_UNKNOWN_DEVICEWarning, 45

CONNECTION_TO_UNKNOWN_PORTWarning, 45

Create MyConfig TopoWithout DO list, 34

Creating an export file, 33CU, external

Configuring, 27

DDevice representation

Ancillary equipment unit, 39PLC unit, 39

DEVICE_EXISTS_MULTIPLE_TIMEWarning, 45

DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGYWarning, 45

DEVICE_ONLY_IN_POWERTOPOLOGYWarning, 45

DEVICE_TYPE_IS_EMPTYError, 44

DEVICE_TYPE_IS_INVALIDDrive object, 43

DEVICE_TYPE_IS_UNDEFINEDError, 44

DialogAssigning drive objects, 28Defining unknown devices, 20Export, 33Settings, 15, 19

DO list, 29Project path as output path, 19Setting an absolute path, 19Settings, 18

Drive objectDEVICE_TYPE_IS_INVALID, 43DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNED, 43DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LIST, 43DRIVEOBJECT_IS_UNASSIGNED, 43ERR_GLOBAL_DO_LIST_NOT_FOUND, 43

Drive objectsAssigning, 28filtering, 32

DRIVE-CLiQ typesList, 41

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 49

Siemens Parts

Page 50: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

DRIVECLIQ_MULTIPLE_WIRINGError, 44

DRIVECLIQ_NO_MASTER_FOUNDError, 44

DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNED

Drive object, 43Warning, 46

DRIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LIST

Drive object, 43Warning, 46

DRIVEOBJECT_ERROR_WHILE_READINGWarning, 46

DRIVEOBJECT_FILE_HAS_DUPLICATE_IDSWarning, 46

DRIVEOBJECT_FILE_IS_EMPTYError, 44

DRIVEOBJECT_FILE_IS_INVALIDError, 44

DRIVEOBJECT_IS_UNASSIGNEDDrive object, 43

EEPLAN

Article database, 18, 21Bus data, 22Command line interface, 36Device connection name, 32Display type, 35Equipment parts list, 32Exporting the configuration, 17Keys assignment, 35Minimum requirements on DRIVE-CLiQ topology, 37Minimum requirements on power topology, 38Text fields, 42

EPLAN Add-InLoading, 12, 36Siemens DQ-Topo, 4Version, 9

EPLAN device, 28filtering, 31

EPLAN Electric P8, 12Version,

EPLAN property, 22ERR_GLOBAL_DO_LIST_NOT_FOUND

Drive object, 43ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_PORT

Error, 44

ERR_MULTIPLE_DriveCLiQ_MASTERError, 44

ERR_RING_TOPOLOGYError, 44

ErrorDEVICE_TYPE_IS_EMPTY, 44DEVICE_TYPE_IS_UNDEFINED, 44DRIVECLIQ_MULTIPLE_WIRING, 44DRIVECLIQ_NO_MASTER_FOUND, 44DRIVEOBJECT_FILE_IS_EMPTY, 44DRIVEOBJECT_FILE_IS_INVALID, 44ERR_MULTIPLE_ALLOCATION_AT_DriveCLiQ_PORT, 44ERR_MULTIPLE_DriveCLiQ_MASTER, 44ERR_RING_TOPOLOGY, 44EXCEPTION_READING_BOM_ENTRY, 44EXCEPTION_READING_SYSTEMCONFIGURATION, 44

ExamplesNCU connection, 25

EXCEPTION_READING_BOM_ENTRYError, 44

EXCEPTION_READING_SYSTEMCONFIGURATION

Error, 44Expansion modules

Configuring, 27Export, 33

Equipment parts list, 32

FFile type

*.sdx, 33*.uvdx, 18

filteringDrive objects, 32EPLAN device, 31

HHF modules

Configuration, 38HLA modules

Configuration, 38

Iimport-catalog.log.xml, 18Item designation, 28

Predefined, 38

Index

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-In50 Operating Manual, 12/2017, A5E43099659B-AA

Page 51: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric

MMain menu

Siemens DQ-Topo, 13, 15Master modules

EPLAN database field, 37MasterSystemID, 27Minimum requirements

Power topology, 38

PPLC unit

Device representation, 39Predefined

DRIVE-CLiQ connection names, 37Encoder connection names, 37EPLAN property, 22Item designation, 38

Purpose of the document, 4

RRequirement

EPLAN versions, 9SINAMICS product catalog, 9

SSettings

Dialog, 15DO list, 18DRIVE-CLiQ type, 22

Siemens DQ-Topo, 4, 13Submenus, 15

Siemens.EplAddIn.DQTopo.dll, 18Siemens.EplAddin.DQTopo.dll.eplan.config, 35SINAMICS product catalog

importing, 18Path, 17Requirement, 9Version, 9

SINAMICS-DQ-Komponenten-Katalog.xml, 17Slave

Configuring, 27

TTarget group, 4

topo.uvdx, 29

UUNKNOWN_ECAD_VERSION

Warning, 46UNSUPPORTED_PROPERTY_TYPE

Warning, 46

VVersion

EPLAN Add-In, 9EPLAN electric P8, 9

WWarning

BUS_DATA_IS_NOT_NUMERIC, 45BUS_SYSTEMID_IS_DIFFERENT, 45CONFIGURATION_COULD_NOT_READING, 45CONFIGURATION_COULD_NOT_WRITING, 45CONFIGURATION_UNAUTHORIZED_READING, 45CONFIGURATION_UNAUTHORIZED_WRITING, 45CONNECTION_HAS_SAME_DEVICE_ON_BOTH_ENDS, 45CONNECTION_NOT_HOMOGEN, 45CONNECTION_TO_UNKNOWN_DEVICE, 45CONNECTION_TO_UNKNOWN_PORT, 45DEVICE_EXISTS_MULTIPLE_TIME, 45DEVICE_NOT_IN_DRIVECLIQ_TOPOLOGY, 45DEVICE_ONLY_IN_POWERTOPOLOGY, 45DRIVEOBJECT_COMPONENT_ALREADY_ASSIGNED, 46DRIVEOBJECT_ERROR_WHILE_READING, 46DRIVEOBJECT_FILE_HAS_DUPLICATE_IDS, 46RIVEOBJECT_COMPONENT_NOT_IN_GLOBALDO_LIST, 46UNKNOWN_ECAD_VERSION, 46UNSUPPORTED_PROPERTY_TYPE, 46

With DO list, 34Without DO list, 34

Index

SINUMERIK Integrate Create MyConfig - EPLAN Electric P8 Add-InOperating Manual, 12/2017, A5E43099659B-AA 51

Siemens Parts

Page 52: EPLAN Electric P8 Add-In - ucc.colorado.eduucc.colorado.edu/siemens/840Dsl_EPLAN_Add_In_CMC... · SINUMERIK SINUMERIK 840D sl / 828D SINUMERIK Integrate Create MyConfig - EPLAN Electric